Loading...
HomeMy WebLinkAboutApplication- Permitfob Address Nature of Work Use of Buildin GARFIELD COUNTY BUILDING, SANI'T'ATION and PLANNING DEPARTMENT 109 8th, Street, Suite 303 Glenwood Spriuga, CO 81601(970) 945-8212 No. 8673 Building PeEniit Owner � :Itkct Date Contractor Amount of Permit$ 3/I R /c) Clerk Telephone: (970)945-8212 (I�un t GARFIELD COUNTY BUILDING PBRMff APPLICATION Garfield County (Glenwood Spdngs) Colorado inspection Line: (970) 384-5003 Parcel / Schedule # 2177-362-00-345 C ty . Rd. 319 Rifle Job Address: SE1/43E1/4 Sect. 1 T78 Range 93 W of 6th P.M. 1. LOt#: Block#: Subdivision/Exemption: 2. rEnCana Address: 792 Buckhorn Riff' Wk. Ph: 625-4209 Contractor; pAi.1 Vaughan Address: 1038 OR323Rifle Ph: uoi: 625-5350 4. ArcltitoctIEnginasr:0ddo Eng. Aaron: 710 Cooper G1SprPn:945-1000ct: 28085 5. $q Ft of Building: 240 Sq Ft ofLoll ease 6.94adafsht 101 #of Floors: 1 e. Use offuilding: `Chemical Storage,-} See MSDS and volumes attached T. Describe Work: Foundation and structural steel building B. Class of Work: )b Now ❑ Addition CI Altoratton El Move ❑ Remove g Garage: 0 Single 0 Doubto Carport: ❑ Singta ti Double 10. 0 Driveway Permit 0 On Site &wage Disposal (Septic) 0 Sim Pian Valuation of Work S: 11,300.00 Ad'tustod Valuation $: /.. ®101. Jif 'Special Conditions: WW Group 8 Division 1 NOTICE E ISSUED BY STATE ASt�ARATE ELEECrrLICAL PERMIT 18 REQUIRED AND MUST BE 'R OF COLORADO, PEW THIS PE BECOMES fn t.ANDVODIFWORXORCONSTRUCUCNAIRHon= IS NOTCOMMENCEDV11HN9110DAYS,OR1FGOHSTRUCTiCNORWORKIS SUUSPENDEDORABANOONEDFORA PERIOD OFi811DAYSATANYTIMEAFTk321MCll�i01q iS COMMENCED. 1 HEREBY CERTIFY THAT HAVE READMIT EXAMRIEDTHIS APPLICATION AM KNOW TE SAME TO BE TRUE AND CORRECT ALL FROVISIONS OF LAWSGOVERNINGTHIS TYPE OF WORK WILL, BZ COMPLETED WITH YAMMER SPECIFI DHERENORNO . THE GRANTING OF THE PERMtTDOSS NDT PRESUME TO GWEAUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF NW OT}ERSTAIE OR LCCN. LW ULATENL3 r• - R ORTHEPEFOR IA,MC OFC c . fl Dar .a. . Dahl Piaci Check Fee: 90* . Permit Fee: ) c� ? Z5 . Total Fee: i j Date Fetltiit issued: OCG Group: Construction Type: 4 Zoning: �chNter,CnRractarnr, : • and mien:foodm&csabam.fir e..ry 30.0 • ♦ :read Setbacks: - _ : , (4 Manufactured Home: '31.3dng Dopertr9anl ApproraliData PHrring I : ,& , . • . • oar e ISOs f# Fee : AGREEMENT PERMISSION LS HEREBY GRANTED 7O THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY DEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT. THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING USE REGULATIONS ADOPTED 8Y GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE awn THOPP IT,eriot t ppr.(1$JI men; awn unin THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE rIC Tinn If capcnU`TInM THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION REST SPECIFICALLY WITH DI IN 11115 III (MUM= 1 PeNciisC1rr4 ACC IArrC1.IUCr1 7A DC nrcleCDIiATri/C AMJr1 IM 01 Il="151. AC TUC ALLMICDC 11rrvaccrr Galena= I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE, (INITIAL)IN OR OWNER TO THE BUILDING CODES AND LAND THE SIGNER ERECTION, CONSTRUCTION COUNTY AND THAT THEN BUILDING OFFICIAL FRLIM FROM PREVENTING OR REGULATION NOT CONSTITUTE AN DISCREPANCIES. THE THE ARCHITECT, DESIGNER, Y The following items are required by Garfield County for a final inspection: 1. A final Electrical inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stoat, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL LL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupant , use and the issuance of a Certificate of Occupancy for the dwelling under building permit # -IA\ to Signature Date Bpcont082002 PLAN REVIEW CHECKLIST Applicant EiqC, 4 Date Building -Engineered Foundation' r�7 Driveway Permit -iurveyed Site Plan 4/ 4. Septic Permit and Setbacks ✓Grade/Topography 30% an review -File Notes )(1, 4 Attach Residential Plan Review List ✓ Muumum Application Questionnre Vii. Subdivision Plat Notes '.1. Fire Department Review Valuation Determination/Fees " Red Line Plans/Stamps/Sticker 1014 Attach Conditions t - Application Signed ' �Plan �Reviewer To Sign Application. Parcel/Schedule No. {� 40# Snowload Letter- ManfHms. GENERAL NOTES: 740 Y25 3 = CO72 Rgitur • JO-- o3 Planning/Z + ning Prope Line Setbacks 30 ` Stream Setbacks ood Plain g Height Zoning Sign -off Subdivision Plat N es t Road imp • Fees HO RC Approval ade/Topography 40% Planning Issues anchor bolts, pressure treated plates, floor joists, wail studs and spacing, insulation, sheeting, house -rap, (which is required), siding or any approved building material, A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot. up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure S, windload of 15 pounds per square foot and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plan submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed stmeture, additions orother buildings, setback easements, and utility easements showing distances to the property lines from each comer of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 40% or more on properties must be show on site plan. Yes 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. Yes_ No Not necessary for this project qs . 3. Are the plans submitted for application construction drawings and not drawings that are stamped or marked identifying them as Not for construction, for permit Issuance only", "Apprgval drawings only", "For permit issuance only' or similar language? Yes e( No _ Not necessary for this project l 4. Is the I.S.D.S. (Individual Sewage disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes No Not necessary for this project j 5. Does the site plan indicate the location and direction of the State, County or private road acce/ ing the property? 6. Do the plans Include a foundation plan indicating the stze, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered desdgr? Yes No_ _ Not necessary for this project, 7. If the building is a pre-engineered structure, is there a stamped, signed engineered 2 t found tion plan for this building? Yes No Not necessary for this project_ 8. Do the pians indicate the location and size of ventilation openings for underfloor crawl spaces and the clearances required between wood and earth? Yes_ No Not necessary for project,/ 9. Do the pians indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes No Not necessary for this project_ 10. Do the plans include design toads as required under the Uniform Building Code for roof snow)gads, (a minimum of 40 pounds per square foot In Garfield County)? Yes `I No Not necessary for this project. 11. Do the plans include design toads as required for floor loads under the Uniform Building Codephapter 16 and Tables 16A, 16B and 16C? YesJJNo__. Not necessary for this project 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof nstruction? Yes, .. No Not nacsssary for this project 13. Is the wind speed and exposure design included In the plan? Yes .1 No Not necessary for this project 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? ,/ Yes . No.. Not necessary for this project 15. Does the building section drawing or other detail Include the method of positive connection of all columns and beams? Yes No Not necessary for this project 16. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the save down to existing grade contours? Yes No Not necessary for this project 17. Does the pian Include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase 11 EPA certification? Yes__ No Not necessary for this project) 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 31? Yes No Not necessary for this project 3 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes No Not necessary for this project/ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes_ No Not necessary for this project'.. 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing Immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? / Yes No Not necessary for this project`/ 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes No Not necessary for this project ei 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5-A) Yes .. f No Not necessary for this project 24. Does the plan indicate the quantity, form, use and storage of any hazardous materiais that may be in use in this building? Yes d No Not necessary for this project; 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No Not necessary for this project �! 25. bo the plans indicate the location and dimension of restroom facilities and if more Than four employees and both sexes are employed, facilities for both sexes? Yes No Not necessary for this project 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? ` Yes No Not necessary for this project " 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes �% No_.�..___ 29. Have you designed or had this pian designed while considering building and other constryction code requirements? Yes J No Not necessary for this project 4 30. Does the pian accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes,/ No 31. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes j No 32. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes No 33. Are you aware that you are required to call for ail inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occup ncy and occupancy of the building? Yes No 34. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party }responsible for the project complying with the Uniform Codes? YesJ No 35. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale, in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 4:00 p.m. the day before. Failure to give twenty-four (24) hour notice for lnspecttons will delay your inspection one (1) day. Inspections are to be called in to 384«5003, 36. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes _/ No 37. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes . No 38. Are you aware, that on the front of the building permit application you will need to fill in the Parcell Schedule Number for the lot you are applying for this permit on prior to issuance of the building permit? Your attention in this is appreciated. Yes J No 5 I hereby acknowledge that 1 have read, understand, and answered these questions to the best of my ability. Signature 0 , CNgV sZ\.\\---(3)1-;\ N-f,„\CX, Date -)._\A� Phoned/ ' S S -D (days); ��� 70�� $ (evenings)— Project Name:.c e h- ; cr,..\ ��� _ Et) c— rst s } ProjectAddress:S'L 1`A 5E) k stL..T13 Oc 6-,�°t-c . If you answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the Information is necessary to review the application and plans to determine minimum compliance with the adopted codas, please expect the following: A, The application may be placed behind more recent applications for building permits In the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. *if you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. Bpcomm 04102 t EnCana 011 & Gas (USA), Inc. 792 Buckhorn Rifle, CO 81650 970-625-4209 Hunter Mesa Chemical Storage Building MSDS and items to be stored including volumes 2121/03 MATERIAL SAFETY DATA SHEET The Valvoline Company Page 001 Date Prepared: 01 1402 Date Printed: 08 01 02 MSDS No: \\ 505- pp NT S}o-rS'-'7� 0 IOksQUAt E Y -A tT--Wit HPDR 0 -II, ISO 32 0273 1- CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Material Identity Product Name: VALVOLINE QUALITY ANT -WR HYDR OIL ISO 32 SAP Material No: VV7 General or Generic ID: PETROLEUM BASED -LUBRICATING OIL Company Telephone Numbers The Valvoline Company Emergency: 1-800-274-52 P' 0^ Box 14000 Lexington, KY 40512 Information: 1-85 2- Ingredient(5) COMPOSITIONINFORMATION ON INGREDIENTS CAS Number % (by weight HYDRAULIC OIL 100- 0 3- HAZARDS IDENTIFICATION Potential Health Effects Eye Unlikely to cause eye irritation or injury Skin May cause mild skin irritation' ciry and crack the skin Swallowing Prolonged or repeated contact may } sF Swallowing small amounts of this material during normal handling is not likely to cause hariful effects- Swallowing large amounts may be harmful MATERIAL SAFETY DATA SHEET The Valvoline Company Page 002 Date Prepared: 014.4 /02 Date Printed: 08/01_102 MSDS No; 505~ VALVOLINE QUALITY ANT -WR HYDR OIL ISO 32 0273 Inhalation It is possible to breathe this material under certain conditions of handling and use (for example, during heating, spraying, or stirring)- Symptoms usually occur at air concentrations higher than the recommended exposure limits (See Section 8) Symptoms of Exposure stomach or intestinal upset (nausea, vomiting, diarrhea) irritation (nose, throat, airways), pain in the abdomen Target Organ Effects No data Developmental Information No data Cancer Information No data Other Health Effects No data Primary Route($) of Entry Skin contact c t' 4- FIRST AID MEASURES Eyes Skin If symptoms develop, move individual away from exposure and into fresh air' Flush eyes gently with water while holding eyelids apart• If symptoms persist or there is any visual difficulty seek medical attention Remove contaminated clothing~ Wash exposed area with soap and water' If symptoms persist, seek medical attention- Launder clothing before reuse MATERIAL SAFETY DATA SHEET The Valvoline Company Page 003 Date Prepared: 01 Date Printed: 08 MSDS No: 505- 027.3 VALVOLINE QUALITY ANT -WR HYDR OIL ISO 32 Swallowing Do not induce vomiting• Give one glass of milk or water, and get medical attention immediately- If possible, do not leave victim unattended Inhalation If symptoms develop, immediately move individual away from exposure and into fresh air- Seek Immediate medical attention keep person warm and quiet- If person is not breathing, begin artificial respiration' If breathing is difficult, administer oxygen Note to Physicians Preexisting disorders of the following organs ( or organ systems may be aggravated by exposure to this material: skin 5 FIRE FIGHTING MEASURES Flash Point 350 - 0 F (17 Explosive Limit No data Autoignition Temperature No data Hazardous Products of Combustion May form: carbon dioxide and carbon monoxide, oxides of sulfur nitrogen and phosphorus, various hydrocarbons Fire and Explosion Hazards Never use welding or cutting torch on or near drum (even empty because product (even just residue) can ignite explosively.' ------ smoke may be gene.ated while burning The Valvoline Company MATERIAL SAFETY DATA SHEET Page 004 Date Prepared: 01 1402 Date Printed: 080102 MSDS No: 505 --- VALVOLINE QUALITY ANT -WR HPDR OIL ISO 32 Extinguishing Media regular foam, carbon dioxide, dry chemical Fire Fighting Instructions Water or foam may cause frothing which can be violent and possibly endanger the life of the firefighter° breathing apparatus with a full facepiece operated in the positive Wear a s pressure demand mode with appropriate turn -out gear and chemical resistant personal protective equipment protective equipment section of this MSDS NPA Rating Health - 1, Flammability - 1, Reactivity - 0 Small Spill Absorb liquid on vermiculite, floor absorbent or other absorbent material Large Spill Prevent run-off to sewers, streams or other bodies of water run-off occurs, notify proper authorities as required, that a spill has occured Persons not, wearing protect should be excluded from area of spill until clean-up has been completed Stop spill at source, dike area of s spreading, pump liquid to salvage tank Remaini taken up on sand, clay, earth, floor absorbent, or other absorbent material and shoveled into containers HANDLING .AND STORAGE Handling Containers of this material may be hazardous when emptied --- emptied containers retain product residues (vapor, liquid, and or solid), all hazard precautions given in the data sheet must be observed The Valvoline Company MATERIAL SAFETY DATA SHEET Page 005 Date Prepared: 01 14 02 Date Printed: 08 MSDS No: 505- 0273 VALVOLINE QUALITY ANT --WR HYDR OIL ISO 32 Storage Not applicable 8- EXPOSURE CONTROLS Eye Protection Not required under normal conditions of use - However, if misting or splashing conditions exist, then safety glasses or chemical splash goggles are advised Skin Protection Not normally required- However, wear resistant gloves such as nitrile rubber to prevent irritation which may result from prolonged or repeated skin contact with product- , Wear normal work clothing covering arms and legs - Respiratory Protections Not required under normal conditions of use- However, if oil mists are generated above recommended PEL NIOSH MSHA approved environmental control- (See your industrial. hygienist - Engineering Controls Not required under normal conditions of use- However, if unusual operating conditions exist, then provide sufficient mechanical (general and below PEAL TLV (s) Exposure Guidelines Component or loca HYDRAULIC OIL 8A+ No exposure limits established MATERIAL SAFETY DATA SfEET The Valvoline Company Page 00 Date Prepared: 01 Date Printed: 08 MSOS No: 505E ......-•- VALVOLINE QUALITY ANT -WR HYDR OIL TSO 32 Boiling Point Not applicable Vapor Pressure Not applicable Specific Vapor Density > 000 @ AIR=1 Specific Gravity Liquid Density 7 ......... Percent Volatiles (Including Water No data Evaporation Rate SLOWER THAN ETHYL ETHER Appearance No data State LIQUID Physical. Form 0273 PRYSTCP 13 10.1 13 kc No data Color CLEAR TO LIGHT YELLOW The Valvoline Company MATERIAL SAFETY DATA SHEET Page 007 Date Prepared: 01 /14 /02 Date Printed: 08 ,01 102 MSDS No: 505 VALVOLINE QUALITY ANT -WR HYDR OIL ISO 32 Odor pR No data Not applicable 10 -- a. STABILITY AND REACTIVITY Hazardous Polymerization Product will not undergo hazardous polymerization Hazardous Decomposition May form: carbon dioxide and carbon monoxide, oxides of sulfur nitrogen and phosphorus, various hydrocarbons Chemical Stability Stable Incompatibility Avoid contact with: strong oxidizing agents TOXICOLOGICAL INFORMATION No data 12 -ECOLOGICAL INFORMATION No data 13 ...-DISPOSAL CONSIDERATION Waste Management Information Dispose of in accordance with all applicable local, state and federal regulations MATERIAL SAFETY DATA'SHEET The Valvoline Company Page 008 Date Prepared: 01 /14 A2 Date Printed: 08 ,41 ,02 MSDS No: 5050273 VALVOLINE QUALITY ANT -WR HYDR OIL ISO 32 14 '-TRANSPORT INFORMATION DOT Information - 4 DOT Description Not Regulated Container Mode CASESMURFACE - NO EXCEPTIONS NOS Component None RQ (Reportable Quantity) - 4 Not applicable 15 "'REGULATORY INFORMATION US Federal Regulations TSCA (Toxic Substances Control Act) Status TSCA (UNITED STATES) The intentional ingredients of this CFR 1721° product are listed CERCLA RQ - 40 CFR 302. 4 None SARA 302 Components - 40 CFR 355 Appendix A None Section 311 312 Hazard Class -- 40 CFR 370- 2 Immediate(X) Delayed( ) Fire( ) Reactive( ) Sudden Release of Pressure( SARA 313 Components - 40 CFR 372» None The Valvoline Company MATERIAL SAFETY DATA SHEET Page 00 Date Prepared: 011402 Date Printed: 080102 MSDS No: 505~ VALVOLINE QUALITY ANT --WR HYDR OIL ISO 32 0273 International Regulations Inventory Status Not determined State and Local Regulations California Proposition None 1 OTHER MNFOF The information accumulated herein is believed to be accurate but is not warranted to be whether originating with the company or not- Recipients are advised to confirm in advance of need that the information is current, applicable, and suitable to their Mil Fir; Y°Yicfly MATERIAL SAFETY DATA SHEET I. PRODUCT IDENTIFICATION Manufacturer: WD -40 Company Address: 1061 Cudahy Place (92110) P.O. Box 80607 San Diego, California 92138-9021 RiJlefir�i� 2� it sp. r+'�r "AA J Emergency Telephone: (619) 275-1400 Chemical'Name: Organic Mixture Trade Name: W©-40 Aerosol II. HAZARDOUS INGREDIENTS Chemical Name Aliphatic Petroleum Distillates A-70 Hydrocarbon Propellant Petroleum Base Oil Corrosion Inhibitor Wetting Agent Fragrance 1/14,t)itv- Aye-401-1,ot CAS Number 8052.41-3 88476-85-7 8012-95-1 Proprietary Mixture Proprietary Mixture Proprietary Mixture 50 25 > 15 < 10 < 5 < 5 Exposure Limit ACGIH/OSHA 100 ppm (PEL) 1000 ppm (PEL) 5 mgIM3 (TWA) 5 mgIM3 (TWA) 500 ppm (PEL) NDA Ili. PHYSICAL DATA Boiling Point: vapor Density: (air = 1) ., Solubility in Water: Specific Gravity (€-120 = t) Percent Volatile (volume): NA Greater than 1 insoluble .710 0 70°F 80% Evaporation Rate: Vapor Pressure: Appearance: Odor: Not determined 50 PSI 70°F Light amber Characteristic odor IV. FIRE AND EXPLOSION Flash Point: Flammable Limits: Extinguishing Media: Special Fire Fighting Procedures: Unusual Fire and Explosion Hazards: NA to aerosol carts (propellant portion) (Lel) 1.8% Well 9.5% CO2, Ory Chemical None Considered "extremely flammable" under Consumer Product Safety Commission regulations. V. HEALTH HAZARD INFORMATION Threeheld Limit Value Aliphatic Petroleum Distillates (Stoddard solvent) lowest TLV (ACGJK 100 ppm.) Symptoms of Overexposure Inhaled Vapor: May cause anesthesia, headache, dizziness, nausea and upper respiratory Irritation. Skin Contact: May cause drying of skin and or irritation. Eye Contact: May cause irritation, tearing and redness. Swallowed: May Cause Irritation, nausea, vomiting and diarrhea. Aspiration into Lungs: May cause chemical pneumonitis. First Aid Emergency Procedures Swallowed: Do not induce vomiting, seek medical attention, Eye Contact: Immediately fiush•eyes with large amounts of water for 15 minutes. Skin Contact: Wash with soap and water. Inhaled: Remove to fresh air, Give artificial respiration if necessary. if breathing is difficult, give Oxygen. Suspected Cancer Agent vin Kin x Thn r.mmnnnents in this mixture have been found to be noncarcinogenic i ft Stab illy: Conditions to avoid: Incompatability: Hazardous decomposition products: Hazardous polymerization: Stable X Unstable NA Strong oxidizing materials NA May occur Will not occur X VII. SPILL OR LEAK PROCEDURES Spill Response Procedures Spill unlikely from aerosol cans. Leaking cans should be placed in plastic bag or open pail until pressure has dissipated. Waste Disposal Method ,..1 !'Empty aerosol cans should not be punctured or incinerated; bury In land fill. Liquid should be Incinerated or burled in land fill. VIII. SPECIAL HANDLING INFORMATION Ventilation: Sufficient to keep solvent vapor less than TLV. Respiratory Protection: None required. Protective Gloves: None required. Eye Protection: None required. Other Protective Equipment: None required. IX. SPECIAL PRECAUTIONS Keep from sources of Ignition, do not take internally. Avoid excessive inhalation of spray particles. Do not puncture, incinerate or store container above 120°F. X. TRANSPORTATION DATA ttrrsastfc Suriaoe Jescription: Consumer Commodity Hazard Class: ORM-D ID No.: NONE Label Fiequired: Consumer Commodity (ORM-D) Domestic Air Description: Consumer Commodity (Flammable Gas -Aerosol products) Hazard Class: ORM-D ID No.: NONE Label Required: Consumer Commodity (ORM-D-AIR)' w SIGNATURE: R. Miles � lEVISION DATE: April 1986 TITLE: Technical Director SUPERSEDES: December 1985 VA 0, Not applicable NOA No data available C - Less than 3 More than Ve believe the statements. technical information and recommendations contained herein aro reliable. However, the data is provided withasri warranty, :xpiessed or implied. It is the users responsibility both to determine safe conditions for use al this product and assume loss, damage or expense. • • •• •• . ....J lwLwi } "rhis MSDS should be attached or kept with the respective product with which it is associated. 21147 CRC MATERIAL SA1377 DATA 011067 SIL00 CAC INOU1TR140, INC. 005 LOUIS DRIVE 11)41340710. ph 30974 12151 474-4300 FOA 24 NA. 110IR0ENCY R11O NATION CA4L C11sHCA1C I-100.424.9300 PAOCCCT Hump 11011-CSJ40A. EW,XL5EH (A1703302.3 1-0490005000 PA00001-03000. 05004-f. 08080P, 1500; 1. IJIORJWII3TTS CAS 0 ALOIN TLV 09311 P10. 000401 LIMITS T0622131 40R'HAIOL AC450011 CAM% DIOXIDE 0430-03-3 200 PPA 07-04-1 140 PPM 07.44.1 700 0114 124.34-9 5000 Ppm 2. PH7SICA4 DATA (NITNOi0T PROpn,L?NT) 200 0114 00 PPM 710 PPH 10000 23.32 15.2E 30.40 IIT 10 Orroxrsc 00111 1Y, 0.015 V POA PAILMIX4 NA 00111.130 POINT. 121 1 (INITIAL) t+ VOLATILE, 100 711003710 POINT: 110 EVAPORATION RAT;: 1ASR VAPOR 01111ITY: ND PR: NA 300414/LI 7. PARTIALLY 001060/1 IN NATER. 900.01)110 IN H007 00012130 1200ID5. AP01AAA301 11240 OCOR, 013014, HNTAR WRITE LIQUID. 3. 77RA AND IMPLOSION DATA PL.4' 04001040= LT 4 t 1MTHo0: TCC 7L2241A31( LIHIT2s I1TI11ATED 414 • 1.6 Dib - 13.4 AxTINotH3NINCI M71DIA. CO2, *ohm, too, =mum, 041111.01: 1500000. CANS HAY lt1AST 110010 220 7. 4. ARA.CTIYITY AND STAAILITY 5T111IL1TY: 0TA5L4 HA/ARCO/4 03COMPOSI7I020 PRODUCTS: 0021 CA[4EW1 MONO1I0;. 3 0401.070 TO AVOID, STRONG 0X10I011443 04310000 ANN 200101$ 01 1.004772044. 5. PAOTECTICA INFORMATION VDR'I1*71011i AOECOATL TO 044110NT ACCOHULATTCf D7 700000. RESPIRATORY* 301 9117-c0t8TAI101D 110711Tim=NO APPARATUS AEOVA T4V. OtmVEo, 100.111212 RISISTAKo. 1'11 4 TACE: SUITT CLASSES. COMA 2440IICMV; scuunwri 0111904 OA0Y101TON It N101S0AAY. 4. HEALTH HAZARD DATA PAg0 1 PLUMY 1010311 01 FUTAY: SAZZ1. INHALATION SIGNS AND SYMPTOMS OF 1X1010.01, 1. ACUTE OVEREXPOSURE: INHALATION, DIx1IOTIE. ORIATI 1:00 DrTrrc LTIE1, AHI3TFD17I0 1174071, 11AD014A, MAY IRRITATE RESPIRATORY TRACT. RYES, MAY 33 IRRITATING. SA2H. TENDS TO DRY rat DEMI' 130 1. 7. CHRONIC OVEREXPOSURE, 001700.7 DERMATITIS. CHROMIC 0VER324009UR3 MAY CAVO; HI1000* 6YST871 aAMA0E. 312D0CAL C0MDITI0IJ; Own:As 7 AGGRAVATED 1Y 1XPODUA0: ;AJIATHI3tG 0R006EH3. NNANATIONALL TOXICOLOGY PROGRAM HO MICAL LISTITO A4 CAMINO:mu 01 00TIDYTIAL CAAQLFI00G'I: 7050 MONOGRAPHS - NO 04141 - N0 10A74CY AND FIRST AI0 PX00000R1St (IF SYMPTOMS PERSIST, CALL A PHYSIC3ANI I712D1[.ATiOf!. UMW TO 701311 AIX. APP07 AATXPICIAL 32351IAATI021 IF E3CEINAAY. gm, rum WITH LARGE AMOUNTS 07 NATER FOA IS MINUTES. SILO: WASH WITH NATER - 11.34001 00MTAMRIAUD 0ICT1INO. INOZ3TICN: DO N0T INDUCE VOMITING. CULL A PHYSICIAN. 7, 701141 OA LEAK 04001121113 PAECAt37IO42 TO 34 TAX1N IN JIANOLxNG AND =MUM* ST021 IN A COOL, DAY AREA. AEROSOL CANS SHOULD 11 91'01;D 1031.031 120 r. STEPS 157 11 TAW IN CASE MATERIAL I9 JUILE 1010 0R SPILLED, 3+311 511000.1) 31 VE14712.ST30 AHD AN 1;00041040 WIRD TO p1C1 UP EXCESS MAT1;IAL, W.WT1 DISMAL, AL1. US701 AND U1RJ51D PRODUCT SHOULD S; DISp0900 0? X11 CONs0AMA12CE WITH LOCAL, STATE AND FEDERAL REGULATIONS. I. SPACIAL PRECAUTIONS AND USE DIRECTIONS VAPORS WILL COLLECT IH LOW AREAS/ ER 8081 TO 117.33iTAIN ADEQU3T3 VENTILATION AND 113; 114 113110 WITH NO 400AC12 OP IGNITION. 9. NIDA HAZARD RATINGS 04;1177( - 2, P43FE610ILITf - 4 10. SARA IM7ORMATICII REACTIVITY - 0 THIS PRODUCT c024710N= TUN 1OLLOW vo CN$IXCRG$ numas 8013100 10 AILSASE RAPOAT1Ti0 COH3ER SICTIQM 313 Or SAA? T1'TL1 IIT, C11a1ICAL NUM 03LS 4 moor '1014)1112 145.10.3 22-32 HATHA3104 07 -$s -I 15-25 01APAR10 0Y, 4503( 51119131 Mart= DAT% 0R on; or 01VIS2011, 05.25-07 vagi 3 (Last Page) 4 �'Glis MSD$ should be attached or kept with the respective product with which it is associated. 60 kq 111. 8AB1r7Y DATA 8HE1'i SIL00 INDUSTRIE9, =NC. 005 LOUIS DRIVE WARHZt1STER, FA 10,74 (215) 674-4300 24 HR. 6I40WEHCY INFORMATION CALL CNEklTAEC 1-800-424-9300 :DUCT HAMA: CONTACT CLEANER 1000 N-monsolso ROOIICT-03150 INGREDIENTS Ci 5 * ACOIN TLV orrA ?EL OTIE8A =KM t =HAMS RG 1-7LItORO- 1717-00-6 500 PFM GT 10 0 MON DIOXIDE 1.24-38-9 9000 PAH 10000 PHYSICAL DATA (WITNCGT PIWPELLAMT) 1CIFIC GRAVITY: 1.24 40 70 T VAPORPRESSURE: 31I11N0 POINT: NO 10 65/4 O 70 F 0LI2G PO/RT: 99.6 F EVAVORATION AAT*: FAST FOR DENSITY! 4.1 (7.x70-11 FE: NA LUBILITY: SLIGHT IN WATER 7977AECS AND 06012: CLEAR. COLORLR9S LXQOXO WITH A PAINT ET7XREAI. ODOR FIRM AND EXPLOSION DATA AM:POINT: HONE METHOD. TCC AMMASLE LIMITS. LEL - 1.1 DEL • 17.7 TIN0RI5142N0 MEDIA. WATER FOG. 032, DRY CHEMICAL. HOWL HA1AR05i 757QSOL9 MAY EXPLODE WHEN HEATED =DVS 120 6. REACTIVITY AND STABILITY ABILITY: STASIS .2ARDOUB DECOMPOSITION PRODUCTS: HALOGENS, HALOGEN ACIDS, POSSIBLY Al6HEN*. C, L *AL9 20 AVOID IN AVOID: HAMS SI UCHH A9 ALIi71NUt6, HAQNESIUH. CALCIUM. PROTECTI4N 717QA47.10070 ENTILATION. USE MECHANICAL KERNE IF NECE59ARY TO 117INTAIN VAPOR CONC. BELOW 11 TLV. piktATORYt AEOVS TLV US1 SELF-CONTAINED BREATHING APPARATUS. Page 1 LOVES: SOLVENT RESIaTAIIT. 51 i VACS: SAFETY owns. THBR PROTECTIVE EQUIPMENT: NOT NORMALLY REWIRED WITH AEROSOL PRODUCT 0397.05. REALTH W11AFD DATA namir 120OTE5 07 ENTRY: INHALAT1014. OXIN I3N9 AND 37)101OM3 OF SXPOSURIe ACOTE OVEREXP09ESS *NIALATION: 0013ID993, 1 08TMEAOEON889. 10200 LEVELS MAY 47.0399 ASPHYXIATION R CARDIAC ARRHYTHMIAS, E2NE MAY 47.1197. D*7ATTI110. IRRITATION. 101; MAY CAUSE 1A:2ITAT1021. CHRONIC OVE5EXA03UR1: =BIN IRRITATION ON REPEATED CONTACT. . IMPAIRED CAROIOVASCULAR 'tEDICAL UNCTION SUCH CARD=7 Y YTRMI B MAY ES BANSTaD BY �S1D AV /NHALATI . 0151424] . TOXICOLOGY Y4DR4ORA2� OO POTffiNTIA2, CAACINOUSNe 'ARC )A?NOORAPNS - NO )SNA - NO IMEROENCY ARD FIRST AID 960CE0DAAs: (IP 0Y60PT6665 PERSIST. CALL A PRY5IC1AW) INHALATION. REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION IP NECESSARY. 3150: PUNA WITH LAMA AMOUNTS Or MATE70 7070 15 mamas. 3X171: WASH AREA THOROUGHLY WITH sorts AND RATER. INGESTION: DO NOT INDUCE VOMITING. GIVE WATER TO DRINX. 0ET ri9D2CAL ATTENTION. 7. SPILL OR LEAX PROC7DURE5 7.55403 '20)10 '10 BS TAXEN IN Mom= ANG STORAQE: 9TORR 22011 COOL, DRY AREA. STEPS TO 9E TA.'C*1 IN CAB5 1IATER17T. IS MUSED OE SPILLED: EVACUATE PERSONNEL. VENTILATE AREA. AE907010 SPILL HITS AN ABSORBENT MATERIAL. matt FORMANCEWLITH LOCAL. USED L. S ANTE �S��L R=EOE071 lis Vis. DISPOSED o8 IR B. 32007AL PRECAUTIONS ANO VAX DIRECTIONS 80907 CAN my AIOXYGEN WOULD BE DISPLACED AND PEYXIA?ICEI COULD WILL - IN Lae 1 T. G0001 D VXliTILA'T2DN 19 A M09T !'OR 1,02007 CONFINED AREAS. 1.1-DICHL0E0- iT ROsTUANE I8 909.110? TO SNUB ROLES OUTLINED IN 40 CFR 791.1007. :BGA NOTIFICATION REQUIRED.- . Daga EQUI 9D.- PAga 1 9. NBP. HAMAAD RATINGS 166611 H - 1 7LA341AE1LITY - 0 5EACPIVITY - 1 10. SARA INFORMATION 11IFOAT270 UNDER r SECTIAAA ON 3130010SAAA TIroo 1TLffiCAL9 THAT ARE summer TO Arms* cu[EMICAL NAME CAS * 2144492 1 1,1-DIC4D.4R0-I-FLD0EOETHAtf3 1717-00-6 GT 90 71:271050 BY: ADAM 9SLI9EER 01201NA3 OATS DADA= 07 171VISION. 06-23-47 co - 0 S1 \1 Peg1 3 CLIC Bagel w The Valvoline Company DE.X.RON LII MERCON MATERIAL SAFETY DATA SHEET Page 001 Date Prep^.r d: '1;01,":1 Date Printed: 11121:98 1•ISDS No: 505.0200299-007.001 \ Co ;:ate 1. CHEMICAL PRODUCT AND (7.01SCPANY IDENTIFICATION ttateriAl !dentitY Product Name: DEUON ttt :jl;,;:O,v l'rodiu :t Cod? 35300512 t;e.iu,cul or. Generic IU: Pi,Tit0:,EGit BA SED-GUORICAiiNf; OIL company The Valvoline Company P.O. Box 14000 Lexington, KY 40512 Telephone Numbers Emergency: 1-600-274-1263 Information: 1-606-337-7147 2. COMPOSITION/INFORMATION ON INGREDIENTS ir_gredien; i s) CAS Number (by weight) ALIPHATIC i'ETRDLEU:t DISTILLATES TRANSMISSION FLUID PACKAGE AROMATIC HYDROCARBON . 64742-65-0 73.0- 83.0 17.0- 27.0 108-88-3 0.1- 0.1 f '3, HAZARDS IDENTIFICATION Potealiel Health Effects Eye Can cause eye irritation. Symptoms include stinging, tearing. redness, ,and swelling of eyes. Skin Can cause skin irritation. Prolonged or repeated contact may dry Lite skin. Symptoms may include redness, burning, and drying and cracking of skin, barns mild other skin damage. Additional syamptcros of skin contact mav inc le ie: allergic skin reaction (delayed skirt rash which may be Lo3.Lawea by blistering. ss:.e 11 a4 end otter sen effects), Pas is ge of this material into ilea tLe skin is possible but it is unlikely chat this would :result in h3rrn fe l effects during safe handling and use. Sua 110ti t ttg Swallowing small amounts of this material during normal handlin, is not likely to cause harmful effects. Swallowing Large amounts may be harmfu). This material can entee the lungs during swallowing or vomiting and cause leng inflammation and/or damase. lahalation Breathing of vapor or mist is pcssible. Breathing small amounts of this material during normal handling is not likely to cause harmful efZeer.s. Breathing, large amounts say be harmful. Symptoms usitaliy occur au ,lir cneent:r. "iota, higher than the recommended exposure limits kiC:P t!,,t.1111 Ai. :iir4A toms p f Exposure Signs and symptoms of exposure to this material through breathing, sciallt�witi , and/or passage of the iri,iteirLa1 through the skin may include: metaLLie trash=.. stomach or intestinal upset (nausea, vomiting. diarrhea) irritation (nose. throat, airways) central nervous system excitation (giddiness, liveliness, light-headed feeling) followed by central. nervous system depression (dizziness, drowsiness, weakness, fatigue, nausea, headache, unconsciousness) and Cather central nervous system effects, Muscle weakness, pain In 011e abdomen, lo4.; of coordination. confusion, coram, and death. Continued On Next Page The Valvoline Company DEXRON III MERCON MATERIAL SAFETY DATA SHEET Page 002 [late Prepared: 11;1Vr,'3 Date Printed: 11/2L/98 ?[SDS No: 505.0200299-007.001 Tar►fet Org=an Effects Prolonged intentional toluene abuse may lead to damage to many organ systems having effects on: central and peripheral nervous systems, vi.si'u, :tearing, liver. kidneys, heart .i id blood. Such abuse has been ass�c°iat.d with brain damage characterized by disturbances in gait, personatity changes and loss of memory_ Comparable central nervous system effects have not been shown to result from occupational exposure to toluene. Overexposure to this material (or its components) has been suggested as a cause of the following effects in Laooratory animals, and may aggravate pre-existing disorders of these organs in humans: .mild, reversible liver effects, cardiac sensiti.zatlon, effects on hearing, respirat.ary tract damage (noes, throat, and airways), central nervc'm system damage, Overexposure to this material (or its components) has been suggested as a cause of the fallowing effects in humans, and may aggravate ire -existing disorders. of these organs: cardiac sensitization, kidney damage. Developmental Information Toluene may be harmful to the human fetus based on positive test result,i with laboratory animals. Case sutdiss show that prolonged Intentional abuse of toluene during prognancy can cause birth defects in humans. Canoor information This material is not expected to nawie cancer in humans since it did not c-t=t>e ,:instar in 11boarator_r animals. This ,material is not List -d ss a carcinogen by [ARC, NT? or OSHA. other Health Effects No data Primary Routes) of Entry inhalation, Skin absorption, Skin contact, Eye contact. 4. FIRST AID MEASURES Eyes if .`-'•'npituns tleS:etop, immediately move individual away °_'ta:R exposure ,ir:d fresh air, Flush eyes gently with water for at leash 15 minutes white holding eyelids apart; seek immediate medical attention. :iki 11 Remove contaminated clothing, Wash exposed area with soup and water. iE symptoms persist, seek medical attention. Launder clouting before reuse. Sue) lowing Seek medical attentiou_ TE individual is drowsy or unconscious. do not give anything by mouth; place individual on the left side with the head down. Contact ahysician, medical Facility, or poison control center for advice whether l3 induc-1 • .:;mitin�aif possible, do not leave individual unattended €.;•c1 if symptoms develop, move individual away from exposure and into fresh .sir. [f symptoms persist, seek medical attention. If breathing is.difficult. .administer oxygen. keep person Warm and quiet; seek immediate isted.c•tL attention. Continued On Next rage J The Valvoline Company DEXRON III MERCON MATERIAL SAFETY DATA SHEET Pae 003 Date Prepared: 11/03/()3 Date Printed: 11/21/96 MSDS No: 505.0200299-007.001 Note to Physicians Inhelation of high concentrations of thfa materiel. ae could occur in enclosed spaces or during deliberate abuse, may be associated with cardiac errltythmias. Svmpathominetic drugs may initiate cardiac arrh• thm.ies to persons exposed Le this material. This material is an aspiration hazard. Potential dangee Er021 aspiration must be weighed against possible ural toxicity (See Section 3 Swallowing) when deciding whether to induce vomiting. Pre-oxixting dis_rde e of the following organs ( or organ systems) may be aggravated by exposure to this material: respiratory tract, skin, lung (for example, asthma -like conditions), kidneys centrad nervous system, auditory system, Individuals with pre-existinheartbeats) gifheart exposedto disordersble o (irregular earl.beats) 5. FIRE FIGHTING lE.ASURE3 Flash Point 365.0 i (183.0 Explosive Limit No (Lata Autai'Jfi tion Temperature C) COC No data Hazardous Products of Combustionhon monoxide, various hydrocarbons. May form: carbon dioxide and Fire and Explosion Hazards Never use welding or cutting torch on or near drum (even empty) becatlse prodect (even gust residue) can i.gni.te exploeively. Dense smoke may be geeer'eted ehtle burning. Extinuuishinq Media regular Lt?.1m, carbon dioxide, dry -Chemical. Fire Fighting instructions Crater or foam may cause frothing which can be violent and possibly endanger: Cull life of the firefighter. Wear -a self-contained breathing apparatus with a facepiece operated in the positive pressure demand mode with appropriate turn -out gear and chemical resistant personalprotective equipment. Refer to chs personal protective equipment section of this HSDS. NPPA Rating Hsalch - t, Flammability - 1, Reaetiviiy - 0 8, ACCIDENTAL ilmaNsE MEASURES 3e.i l 1 301 1 1 t1.,...1e!" mv.,rmiculite, floor absorbent or ot:;?r abicrt..Tnt mq :t tt. eer5on3 nut wet r i eg proper personal protective equipment eheuid be eet leded from area of sp.11. Continued On Next Page orN J the 'Valvoline Company DEXRON HI MERCON MATERIAL SAFETY DATA SHEET Page 004 Date Prepared: 11/03/95 Date Printed: 11/21/08 MSDS No: 505.0200299-OO7.081 (.arae Spi l l Prevent ren -oft: to sewers, streams or other bodies of water. If run-off occurs, notify proper authorities as required, that a spill has occuired . Persons not wearing protective equipment should be excluded from area of spill until creanoup it.3s ben completed. Stop spill at source, dike area of spill t:i prevent spreading, ur. liquid to salvage tack. Remaining L qu iai may br. t:tkk i P opfin sand,clay,earth. floor absorbent, or other absorbent ilSc;tgtLT.3l awl shoveled 1i t0 c, ittainers. • .7. IIA°iDLINO AND STORAGE HandlingC of this material may be hazardous when emptied. Stv{.e emptied containers retain product residues (vapor, liquid, ,furl/or solid), '!1 hlJrl precautions given in the data sheet must be observed. All five gallon Delis nd larger mtal containers including tank cars and tank trucks should be grounded and/or bonded when material is transferred. Warning. Sudden release of hot organic chemical vapors or mists from process equipment operating at elevated temperature and pressure, or sodden ingress of air into vacuum equipment. may resu7,t in ignitions wititout theP�presence of obvious; ignitionsources. P'tblisned autoigtlitton or ignition temperature :-aloos cannot be tt:e ted as safe operating compel:aL tires in chemical processes ivi7:i ono analysis o t tha actual process conditions. Any nse of this product to elevated temperature processes should be thoroughly evaluated to establish avid maLrt; in sate, cep eiatin;y conditioos. Storage Not applicable 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Ere Protection r .,,,i: ;af�r. Wear safetygl/saes in compli: ce with OSHA regulations. (Ccnsi.tl y r::presencati e.) Skin Protection Wear resistant suac,eteritsupplier). yerr eeaedorpoioged (consult your warImpvogs,higd boots. Respiratory Protections If workplace exposure limit(s) of product or any component is exceeded (See: Exposure Guidelines), a NIUSH/:ISHA approved air supplied respirator is advised in absence of proper environmental control. OSHA regulations also permit other S POSH/MSHA respirators (negative pressure type) under specie: Led conditions (consult your Industria hygienist:). Engineering or administrative controls should be implemented to re .uce exposere. E floineertng Controls t1 1 , ♦• 1. ' ?.fit. :tai i3:'.:.� �' P i.•�:: su:.£.i.cieoL yt•:iiirif ai (3.3olr 'E�rVor maintain exposure below TLV(s). Continued On Next Page T5 e Valvoline Company DE)RON IIi MERLON MATERIAL SAFETY DATA SHEET Page 005 Nita P:-epar.04: 11/1::;73 Data Pribted: 11/21/9 MSDS No: 505.0200299-007.001 Exposure Guidel Ines Component As1ti1ATIC PET OLEr1 D{STI;..C,.1T:ES (61.742-65-0) LJH:? VPEL 5.000 in.3/m1 - TWA Oil list ACGIH TLV 5.000 mg/m3 WA Oil `_i ist TRANSMISSION FLUID PACKAGE No exposure limits established ARo:1ATIC ti'tDR0CAREGN (t00-88-3) `o exposure limits estaLlished 9. PHYSICAL AND CHEMICAL PROPERTIES Boiling Point No data Vapor Pressure No data Sped i F to Vapor Dens i tY Na data Speed f to Gravity .875 60.00 F Liquid Density 7.214 1hs; gal '3 60.00 r .373 kgil ;? 15.60 C Percent Volatiles (Including Hater) No data Evaporation )tate SLOWER THAN ETHYL ETHER Appearance No data *tate LIQUID Physical Form No data Cotor RIM PETRO LEC i! Continued On Next Page r, 4 r 3 The Valvoline Company DEXRON III MERCON nil No data Viscosity 6'9-80est 4 29.0 - 42.6 cst > 175.0 ratio MATERIAL SAFETY DATA SHEET Page 006 Date irspac2&: !)/(111:1. Date Printed: 11/21%'98 IiSDS No: 505.0200299-007.001 10. STABILITY AND REACTIVITY Hazardous Polymerization Product will not undersea hazardous polymerization. lia::a r dols Decorapo l i tion Say Corm: carbon dioxide and carbon monoxide, oxides oC sulf'ir.. yind phosphorus, u3rious hydrocarbons. Chem ioal Stability Stablk. inconmatibi 1 i ty ?Acid contact with: strczg oxidizing aoints. t1. TOXICOLOGICAL INFORMATION No data 14. ECOLOGICAL INFORMATION No data 1;.. .-.--._.. ----. 13. DISPOSAL CONSIDERATION Waste Management information 43i.sposa of th ac:cordance with all applicable local, state and fed. rat re.gulatiomi. 14. TRANSPORT INFORMATION COT rn formation - 49 CFR 132.101. DOT De 5c r f pt i oa Not. ne.;,ulatac! Container/Mode: CASES/ SURFACE - NO F. XL.1PT I0iS Continued On Next Page ,w I ) / The Valvoline Company DEXRON TTI MERCON MATERIAL SAFETY DATA SHEET Page 007 ^��i ;at.a Pre aro•i: 1i,r'4 Date Printed: 11/21198 13SDS No: 545.42002.99-00..001 MOS Component: None RQ CReportzahle 2ttatzti ti) - 49 CPR 172.101 Not applic.a to 13. REGULATORY INFORMATION US Federal }Regulations TSCA (Toxic Substances Cantr,ol Act) Status TSCA (►JNLTED STATES) The intentional ingredients of this produt.c sra lasted. CERCLA RQ - 40 CFR 302.4 None SARA 302 Components -- 40 CFR 355 Appendix A None Section 311/312 Hazard Class -- 40 CFR 370.2 Immediate(K) Delayed(X) Fire( ) Reactive( ) Pressure( ) SARA 313 Components - 40 CFR 372.65 Ilona International Regulations inventory Status Not determined State and Local Regulations California Propoii tion 65 Nona Sudden RelA1se 2f 10. C)THE t :NFOR ATION The information accumulated herein is believed to be accurate Lut is not warranted to be whether originating with the company or net. Recipients are advised to confirm in advance of need that the information is c:,►t:r:eet, applicable, and suitable to theit circumstances. Last Page 74 Cer Garfield County Building and Planning Department 109 8th Street, Suite 303 Glenwood Springs, Colorado 81601 970.945.8212 Fax 970.384.3470 Plan analysis based on the 1997 Uniform Building Code Project Number: Project Name: EnCana Air dryer,Chem,MMC Address: Date: March 10, 2003 Contractor: Vaughan Occupancy: F1 Architect: Construction: V -N Engineer: Oddo/Campana Report By: Andy Schwaller NOTE: The code items listed in this report are not intended to be a complete listing of all possible code requirements in the 1997 UBC. It is a guide to selected sections of the code. EXIT REQUIREMENTS: FL NAME NUMB MIN MIN PANIC HALLWAY/ DOOR NOTES OCC EXITS WIDTH HDWR CORRIDOR SWING 1 Multi Bldg. 8 1 1.6 No N/A N/R TOTAL 8 1 1.6 No N/A N/R Door swing is based on Sec. 1003.3.1.5 except as noted. Occupant load factor is based on Table 10-A. Number of exits is based on Table 10-A except as noted. Exit width is in inches and based on Sec. 1003.2.3 and Table 10-B Exit width is to be divided approximately equally among exits. -- Sec. 1003.2.3.2 Width shown for all areas is based on other egress components. Width shown for 1st floor is based on other egress components. Width shown for other floors & basements is based on stairways. --- Table 10-B For the minimum width of doors, see Sec. 1003.3.1.3 For the minimum width of hallways, see Sec. 1004.3.3.2 For the minimum width of corridors, see Sec. 1004.3.4.2 For the minimum width of stairways, see Sec. 1003.3.3.2 Code review for: Project Id.: EnCana Air dryer,Chem,MMC Address: FOOTNOTES: Page # 2 FLUSH AND SURFACE BOLTS: Manually operated edge- or surface -mounted flush bolts and surface bolts or any other type of device that may be used to close or restrain the the door other than by operation of the locking device shall not be used. When automatic flush bolts are used, the door leaf having the automatic flush bolt shall not have a door knob or surface -mounted hardware. The unlatching of any leaf shall not require more than one operation. -- Sec. 1003.3.1.8 LOCKS AND LATCHES: Regardless of the occupant load served, exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. -- Sec. 1003.3.1.8 Key --locking hardware may be used on the main exit when the main exit consists of a single door or pair of doors if there is a sign stating THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS. When unlocked, door(s) must swing without operation of any latching device. -- exc. LANDINGS AT DOORS: 1) A floor or landing shall be provided an each side of doors. When access for persons with disabilities is required. the floor or landing shall not be more than 1/2 inch lower than the threshold. When access is not required, the maximum is 1 inch. -- Sec. 1003.3.1.6 2) Landings shall have a width not less than the width of the stairway or width of the doorway, whichever is the greater. Where a landing serves an occupant load of 50 or more, doors in any position shall not reduce the landing dimension to less than one half it required width. The minimum length in the direction of exit travel is 44 inches. -- Sec. 1003.3.1.7 TRAVEL DISTANCE: (distance to an exit) The maximum travel distance in this building is 200 feet. -- Sec. 1004.2.5 The travel distance for the major occupancy may be 300 feet. -- Sec. 1004.2.5.2.5 Travel distance shall not be limited within an exit enclosure or exit passageway. -- Sec. 1005.2.2 BUILDING ACCESSIBILITY: ROOFING REQUIREMENTS: 1) The roofing on this building is required to be Class C. -- Table 15-A 2) See section 1504 and ICBO research reports for requirements. Code review for: Project Id.: EnCana Air dryer,Chem,MMC Address: Page # 3 VENTILATION: All areas customarily occupied by humans shall be provided with natural ventilation by means of openable exterior openings with an area of not less than 1/20 of the total floor area or shall be provided with a mechanically operated ventilation system. Such system shall be capable of supplying a minimum of 15 cubic feet per minute of outside air per occupant. -- Sec. 1202.2.1 INSULATION NOTES: 1) All insulation material including facings are required to have a flame --spread rating of 25 or less and a maximum smoke density of 450 unless it is in a concealed space and the facing is in contact with a wall or ceiling. -- Sec. 707.3 exc.2 2) Foam plastic insulations are required to be protected. -- Sec. 2602 k�17r 44) Code review for: Project Id.: EnCana Air dryer,Chem,MMC Address: Page # 4 GLAZING REQUIREMENTS All glazing in hazardous locations is required to be of safety glazing material. -- Sec. 2406.3 & 2406.4 locations: 1) Glazing in ingress and egress doors except jalousies. 2) Glazing in fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. 3) Glazing in storm doors. 4) Glazing in all unframed swinginq doors. 5) Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers. Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and drain inlet. 6) Glazing in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24 -inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 7) Glazing in an individual fixed or operable panel, other than those locations described in items 5 and 6 above, than meets all of the following conditions: A. Exposed area of an individual pane greater than 9 square feet. B. Exposed bottom edge less than 18 inches above the floor. Exposed top edge greater inches above the floor. D. One or more walking surfaces within36inches horizontally of the plane of the glazing. 8) Glazing in railings regardless of height- above a walking surface. Included are structural baluster panels and nonstructural in -fill panels. 9) Glazing in walls and fences used as the barrier for indoor and outdoor swimming pools and spas when the bottom edges is less than 60 inches above the pool side and the glazing is within 5 feet of the pool or spa water's edge. 10) Glazing in walls enclosing stairway landings or within 5 feet of then bottom and top of stairways where the bottom edge is less than 60 inches above the walking surface. ri. ,I S. ECM W L .NT e DE UNLESS THIS CAM E EO ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT G RFIELD COUNTY, COLORADO Date Issued k " Zoned Area Permit No.��� AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. UseVAIVAt.., ' 4 IL' Address or egal Descriptio er Setbacks Front Side _Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing v 44 /-T- Foundation Underground Plumbing Ai A. Insulation Ml- Rough Plumbing N Drywall •c/R' Chimney & Vent Al Electric Final (by State Inspectori7l o L. Gas Piping NA Final q,. ,93 /1974 Electric Rough (By State Inspeetoi) /60r Septic Final Framing //,..0397#-- rloo rr .V GAM-*- (To include Roof in p1ae and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - • WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APP VEDDO NOT DESTROY THIS CARD F PLAC D OUTSIDE - COVER WITH CLEAR PLASTIC