Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-11-15-3999 Aspen Signature Homes, LLC Iron bridge PUD Lot# 291 1339 River Bend Way GWS, Colorado 1) SEE PLAN ATIACHMENTS FOR BUILDING REQUIREMENTS . 2) ALL WORK SHALL COMPLY WITH THE 2009 INTERNATIONAL RESIDENTIAL CODE (IRC) AND THE MANUFACTURERS INSTALLATION SPECIFICATIONS. 3) GEOTECHNICAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF COMPACTED STRUCTURAL FILL; 1500 PSF . PROVIDE ENGINEER SEALED APPROVAL REPORT AT UNDERGROUND PLUMBING INSPECTION. 4) PRIOR TO UNDERGROUND PLUMBING INSPECTION, PROVIDE AMENDED FOUNDATION PLAN TO ELEVATE THE SOUTH WOOD FRAMED WALL SIX (6) INCHES ABOVE FINAL GRADE PER 2009 IRC, R-317 . S) STRUCTURAL ENGINEER SHALL FIELD VERIFY PLACEMENT OF REINFORCEMENT BARS, HOLD-DOWNS, AND TENDON INSTALLATION . PROVIDE ENGINEER SEALED APPROVAL REPORT AT UNDERGROUND PLUMBING INSPECTION . 6) STRUCTURAL ENGINEER SHALL FIELD VERIFY MEASURING OF POST TENSIONED SLAB CONSTRUCTION . PROVIDE ENGINEER SEALED APPROVAL REPORT PRIOR TO FRAMING INSPECTION . 7) EXTERIOR WALLS, OPENINGS , AND PROJECTIONS WITHIN 5 FT OF THE PROPERTY LINE MUST COMPLY WITH THE 2009 IRC, TABLE R302.l. (AS NOTED ON PLANS) 8) ENGINEERED ROOF TRUSS SHOP DRAWINGS REQUIRED AT FRAME INSPECTION, 40 PSF. 9) ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED FOR FRAMING INSPECTION . 10) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR CO/FINAL INSPECTION .