Loading...
HomeMy WebLinkAboutApplication- PermitINa. 8628 GARFIELD COUNTY BUILDING, SANITATION, and PLANNING DEPARTMENT ayo 109 8th, Street, Suite 303 `U 2-0 Glenwood Springs, CO 81601(970) 945-8212 Job Address Nature of Work Building Pe m±t Use of Building 5 F Contractor Amount of Permit$ aaBai Date Clerk _ c 3 GARFIELD COUNTY BUILDING PERMIT APPLICATION GARFIELD COUNTY (GLENWOOD SPRINGS) COLORADO TELEPHONE: (970) 945-8212 1 1.0T NO. 3 BLOCK NO. 2 3 OWNaR 379 f-1-41 5Te k/q rT CONIR4C[UR 4 ARaRrEcrADmmER 5 SQ. Fr. OEaU LDINLI 6 7 8 USE OF EATILDING =CRAM WORT.: 761 ce b5#.a—s ,/} •P'0 0 q14-- rD i'fi I�C� R�S Q . f'c Ao /vi rin t e 4 C:?crz.v t —17�iJ F\ INSPECTION LINE: (970) 3 8 4_50 0 3 FARCE SMEDDLE NO. kO 6 / ADAMS ADDRESS 54hPYA `C mCa53//3 PH: WIG PH 5 J LuGNO: MONO: "F7.OFW1 )• 8/ "r /8 's New- g-ty3 c�YlfJl CLASS OF WORK: CADDI ION cAttESA1fON MOVE ORs .10VE NO. OF FLOORS 1 9 GAO-csaptman QSNDL OMITS CARPORT: ODOIA LE •, 10 [UVEWAY PFiI C wKL�Qi�y}V�•PdVti�[� YEN 9717+ SEWAGE DISPOSAL{SEM) >tirruFIeV1 YALVAIIOIDDY WORMS / 7 ) VO0 SPECIAL CQNDI IONS; AMSTED VALVADM1 0-7 NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WHEN 180 DAYS, OR IF .CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FORA PERIOD OF 180 DAYS AT ANY TIME AFTERWORKIS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND .EXAD THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT, ALL PROVISIONS OF LAWS GOVERNINGTHIS TYPE OF WORK WILL BE COMPLIED WTTII WHETHER SPEUWBj.D HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF 0 TRUCTION. R .SIF 4�- ligT Yd '61 Arr KIT 40; gu1ldmgD•„ oval/Dee PLAN CHECK FEE: 820.x( PERMIT FEE: /24.2.5'' TOTAL FEE: 22.33.2/ DATE PERMIT ISSUED: OCC: GROUP: X2.3 (.4-1 ZONING CONST: TYPE: SETBACKS: 1 MANU. HOME: AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUIL I?INGDEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT, THE SIO,IER HEREBY AGREES TO COMPLY WITH AEI, BUILDING CODES AND LAND USE REGULATIONS ADOPTED 1 GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULL COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FRC THE COUNTY AND T13AT DIEN/AND THERE IT SHALL BECOME. NULL AND VOID THE ISStEANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHIERDATA SITALL NOT PREVENT THE BUILDING OFFICIAL REQUIRING T-, CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FRO PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN VIOLATION OFTHIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. TILE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER •DOES NOT CONSTITUTE AN ACCEPTANCE OF AI RESPONSIBILITIES 011,I.1 BIL S BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES.. THE RESPONSJBILTTY FOR THESE HEMS AND IMPLENIENTATB DIMING CONSTRUCTIONRESTE SPECIFICALLY WTIFITIIE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS AREINYENDEDTOBE CONSERVATIVE AND IN SUPP0 OF THE OWNERS INTEREST. Guionn oO3 THEREBY ACKNOWLEDGE THAT WAVE READ AND CJNDERSTANDTIIE AGREEMENT ABOVE. (I NTTIAL` 1 l - ISDS NO, & kEE: 150 °V votc5 The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; S. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all -the required items are completed anda final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT.A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupanc1r u se the issuance of . Certificate of Occupancy for the dwelling under building permit # Kip,20 ,e)6 -?g ,Zttel Signature Bpcont082002 Date VALUATION/FEE DETERMINATION Applicantri:o d� i Address bouhfefrea(baldi i l'" Date F -15—,O1 Finished (Livable Area): Main Upper Lower Other Total Square Feet Valuation Subdivision aA • Commeet P-Atimrom Lot/Block 3 Contractor 0 vo oE.r 0090 = 11ifo, t4 10 Basement: Unfinished Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation (Q 97 x 18 12, Valuation It, cl / LI 4 8. Decks/Patios: Covered Valuation I54 Open Valuation et Total Valuation Building Permit Fee Plan Review Fee Total BP & PR 1 `it s' S S 2O, (2( 208Z.:21 Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house - rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Yes 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes >4 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces's and soffits? Yes 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes xi 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes >° 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (undisturbed) grade contours? Yes ,?Q 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No X 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Buildin Code? Yes No 3 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes >I No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum size a home can be on a lot is a 20ft. x 20ft.? Yes No 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes No 25. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes 71 No 26. Do you understand that approval for design and/or construction changes are required prior to the applic tion of these changes? Yes No 27. Do you understand that the Building Depai 1i ient will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building eArmit? Yes >! No 28. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. All inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes No 29. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes X No 30. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project c mplying with the Uniform Building Code? Yes No 31. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 32. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes %Q No 5 33. Are you aware, that on the front of the Building Pennit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance of a building permit? Your attention in this is appreciated. Yes i7 No Y hereby acknowledge that 1 have read, understand and answered these questions to the best of my ability. . c J ature /- 2 -©Y3 Date Phoner'7b) ca5 - 3/13 (days); (evenings) Project Name;.it_.Q,ILrcp Project Address: V, a6 o Rd. Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 08/2002 Garfield County Road and Bridge Department December 9, 2002 John Stewart P.O. Box 475 Silt, CO CC: Garfield County Building and Planning Department Dear Mr. Stewart, The driveway that exists, at Lot3 CR Commercial Properties, does not need a driveway permit because it does not connect to a county road. If you have any fiirther questions, please feel to contact me at the Road and Bridge Department. Sincerely, Kraig Kuberry Foreman Garfield County Road and Bridge Department 902 Taughenbaugh Blvd. Suite 305 Riffs, CO 81650 Phone: 970-625-8601 Fax: 970-625-8627 PLAN REVIEW CHECKLIST Applicant TJ t Building /Engineered Foundation `iriveway Permit 'urveyed Site Plan `� Septic Permit and Setbacks 'Grade/Topography 30% Plan review -File Notes -Attach Residential Plan Review List &Minimum Application Questionnaire /V,4. Subdivision Plat Notes AL 4, Fire Department Review ‘-.----Valuation Determination/Fees Red Line Plans/Stamps/Sticker N. 4. Attach Conditions y Application Signed ✓ Plan Reviewer To Sign. Application Pareel/Schedule No. 40# Snowload Letter- Manf. Hms. GENERAL NOTES: Date /-45--- 03 Planning/Zoning 17 Property Line Setbacks h 30ft Stream Setbacks Mood Plain uildi g -N f ht oning Sign -off • Subdivision Plat Notes Road Impact Fees HOA/DRC Approval Grade/Topography 40% Planning Issues COUNTY OF GARFIELD - BUILDING DEPARTMENT CORRECTION NOTICE 109 8th St. Suite 303 Glenwood Springs, Colorado Phone 945-8212 Job located at 0) . Permit No, '�j I have this day inspected this structure and these premises and found the following corrections needed: 1. rigs, gm /zt-M.0A. Pam mor I#t-c# Weass j "F ADD I al CJ Zarril cctit hi !,. %A 1S g) �u�v 70I L,7, (-Os . �. 7 S u..44-771- y t1 iM ,) in p o r afi C2w G giogclE. 231egileoPPPT a/Z modTz CadetuoC. Ef4eC SPRaoaog is 5 .7Kti 2Arp$40001 FIN �o e S/o S FF O.V.%isw You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for Inspection. Date 4- 403 19 Phone 945-8212 L'c-44r-44-141-111 ding Inspector 5 t1t..2o at r_ 416.33' x 281.83 —. �$ �• P , R •• 0130 act 3014,^ yrec \_ f (.1•30,1 12.8186 A.* S k. DITCH CROSS FENCING P,7 BOUNDARY WELL F LOT 2 t �9L - ". 9.346 1 SE1/4SE1/4 SEC 34 (-Or -�' a 40 CMP w 10.0' EX1411NG ROAD 30.0' AP kND CAP 80 O W_ d O� SILT PUMP REC.: N0. i \LEA 8,648 Ac.* tri IEC. 34 3.79' 0' ROAR AND CAP • LS 114598 SET g A q. ,PPROVED FOR CONTENT AND FORM ,. AND NOT THE ACCURACY OF SURVEYS. 1ALCULAT1ONS AND DRAFTING PURSU T TO C.R x"51-101 ET SEQ. i OU.TY ..n110 rFRTifN. 5 89.53'OO W COUNTY ROAD #233 CMP r. atwv e csaptickTF 1349.79' l' TELEPHONE PEDESTA ERE SURVEYOK R WL.IUNDER THEHLAWS OFTTNE STATEIOFM CAOLROREGADIOST. TTHAT1 T1115 PLAT 1S A TRUE, CORRECT AND COMPLETE PLAT OF T1IE C.R. CCASEFtCfA! PROPERTIES AT WASP ADE FROM ACCURATESURVEY ID PLATTED AND V SAID SHOWS THE iNspEplamwolAtTAT Num MRS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued".. ,,. BZoned Area Permit No 30'406' AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above°said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Use �� '�t a.�, . ,` �...� ' Address or gal Descript n 6 �' Setbacks Front Side Site Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing Foundation Underground Plumbing - Insulation ; : ,_.0-; Rough Plumbing -, ,, — 0 3 Drywall 7l Chimney & Vent bargameurfirAgre Gas Piping v _03 Final 6-2,0 -� !. Electric Rough (By State Inspector) y „ Septic Final 2--2 0—* Framing _,-1.)- Notes: (To include Roo in lace gid Windows and Doors installed). ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY Date '"9 5'645 . ` By IF PLACED OUTS WITH CLEAR PLASTIC