Loading...
HomeMy WebLinkAboutApplication- PermitJob Address GARkIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th. Street, Spite 303 Glenwood Springs, CO 81601(970) 945-8212 No. 8548 f72aza,L) Nature of Work Use of Buildin Owner0 Contractor Amount of Permit$ Building Permit ( I --CST DD oaR (ajr) t'er77. ) C-4)/ leyeble 6?/ Alf Clerk GARFIELD COUNTY BUILDING PERMIT APPLICATION GARFIELD COUNTY (GLENWOOD SPRINGS% COLORADO 61CiINSPECTION LINE: (970)384-5003 PERMIT NO. � PARCEL/SCHEDULE NO. t y / A 3t/ /fle- C4S1-‘e--- 876 ce7 , TELEPHIONE: (970) 945-8212 JOB ADDRESS: 1 2 3 4 LOT NO. BLOCK NO. C NE 1/4, Section 5, TWAJVI ' ON Smilack Exemption oJames Gornick & Maria sAnr1-107 Px379-17.63 P.O. Box 1296 GWS, 81602 1 "same CONTRACTOR Owner/Builder `RRNtWeinmas ter Home 5 SQ. FT. OFBUD.DOTO 4044 ADDRESS ADDRESS SQ. Ft OVUM PH: Pre LIE,NO: =NO: 7.034 Acres timGur 211 ND, OF FLOORS 2 L MOEHURD= 1P Primary Residence 7 8 9 DESCRIBE 'WORM New CSTIStruction = CLASS OF WORM NJEW S]F OADDIIION OALTF RATION .mm ROUBLE CARPORT: 10 )(DRIVEWAYPFRSHF ..$ a=_.( XON SFffi SEWAGE DISP ORAL (S1 11c) YALVATfiHOEWOAA:3 168,600 SPECTRE. COMMONS: NOTICE A SEPARATE ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE, STATE OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK OR. CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FORA PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT, ALL PROVISIONS OP LAWS GOVERNING THIS TYPE OF WORK 'WILL BE COMPLIED W1TH WHETHER SPECIFIED HEREIN OR NOT. THU GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHOTO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOC ' / LAW RE r i G CONSTRUCTION OR THE PERFORMANCE OF CO ' LIMON. Building De Data 9/e2 ". for or authorized agent Navin .ad and understood notice e. uvai/Date F (4- ! AWE ata (Avic;44,-(A2 a,J.e.o.ta €c // DROVE oDODDLE KiiHPLAN e2.45/ .4 r * CA-) b.)6 art i� ate. FLAN CHECK FEE: //o4, S PERMIT FEE: /699. 35 TOTAL FEE: 2953.93 DATE PERMIT ISSUED: OCC: GROUP: CONST: TYPE: ZONING:: SETBACKS: -MANU. HOME: JSDS NO. & FEEF` AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF IDE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE E DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING -DEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT, Diu SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED E GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28,201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULL COMPLIED W1TH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF TIIE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN BE REVOKED BY NOTICE FRO THE COUNTY AND THAT THEN AND THERE ITSHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT TEE BUI DTING OFFICIAL FROM TBP.REAFIER REQUIRING TI CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FRO PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN VIOLATION OFTHIS CODE OR ANY OTHER ORDINANCE ORREGULATION OF THIS JURISDICTION THE REVIEW OF THE SUBMITTF.I? PLANS AND.. SPECIFICATIONS AND INSPECTIONS CONDUCTED TDEREAFI'ER •DOES NOT CONS RESPONSIBILITIES ORI./ABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS ORDISCREPANCIES. THE RESPONSIBILITY FOR 1 S DURING CONSTRUCTION RESTS SPECIFICALLY WtFSI THE ARCHIFECT, DESIGNER, BUILDER AND OWNER COMMENTS AREJNTENBEDT OF THE OWNERS INTEREST. Garformoo3 Crli10— 0, I HEREBY ACKNOWLEDGETHAT I HAVE READ AND UNDERSTANDTHE AGREEMENT ABOVE. CCEPTANCE OF AN iMPLEMENTATIC AND IN SUPPOI VALUATION/FEE DETERMINATION Applicant C;t5a Mdf, c4 ie Subdivision5Ml kick E P- Address C %LF iOptA,Castil. Lot/Block 0 -- Date ) 0m a 0/, Contractor 0 U3 to➢-eC Finished (Livable Area): Main I64 °? Upper Lower Other Total Square Feet Valuation Basement: Unfinished 1 4 Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: 7T -up t ValUation .- Valuation 7O) I ! J 2 /7 2 Valuation Decks/Patios: Covered Valuation Open Valuation 20b JL4 "4872. Total Valuation Building Permit Fee Plan Review Fee Total BP & PR 22.6 s.2.6 Itp 99. ST Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house - rap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevations an 80 M.P.H. windshear, wind exposure B, windload of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. X 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. Yes 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Yes }( 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent p operties), streams or water courses? Yes 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes )( 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered 2 design? Yes 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces's and soffits? Yes ‘44. ,f 8. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes YN, 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rakers or joists or trusses? Yes 11. Does the building section drawing or other detail include the method ofpositive connection of all columns and beams? Yes !„ 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing ( isturbed) grade contours? Yes 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase If certifications or phase II EPA certification? Yes No /V4 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No /VA 3 V: 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the UniformBuilding Code? Yes Y No 1 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No 17. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes )( No 18. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicatedn the plan? Yes ' No 19. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenan`t� Yes 7., No 20. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes y No 21. Will this be the only residential structure on the parcel? Yes No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes 23. Do you understand that the minimum size a home can be on a lot is a 20ft. x 20ft.? Yes V No 24, Have you designed or had this plan designed while considering building and other construction code requirements? 4 Yes No 25. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes K No 26. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes No 27. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes X No - 28. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 4:00 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes 't No 29. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes )( No 30. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project complying with the Uniform Building Code? Yes No 31. Are you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes No 32. Do you understand that you will be required to hire a State of Colorado Licensed Electrician 5 and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes ' No 33. Are you/ aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance of a building permit? Your attention in this is appreciated. Yes a No I ereby acknowledge that I have read, understand and answered these questions to the est of my ability. ature Phon'? %') 7V - /9', 3 (days); Project Name: 3 Ain s (1bRN/ W 4/# Project Address: /3 /. C1( 67? -2 /3.41„ e/z- Notes: 9//e/C9 Date (900)t 5 7I / (evenings) If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 04/02 6 PR0M : Kurtz Associates, loc. PHONE NO. : Oct. 09 2002 02:iPM P1 K[ RTZ tiL A St GATE l.NC. STRUCTUI,A.'L 'QNSLI .'I'AN S 5012 County Road 154 Glenwood Springs, CO 81601 Phone (970) 945 6305 Fax (970) 945 1093 FAX MMVMDRANDUMDM Date: October 09, 2002 To:.iim Gornick Fax N0.; 87G-1981 Re: Roof Framing for Residence at 214 Peach Valley Roarl•Garfield County, CO, Our office has reviewed the roof framing system for the noted _residence, to include prefabricated roof truss layout and profiles as provided by Trus. -Fab of New Castle, Co. i understand that header material is to be tither Hem -Fir, ir, Select Structural or Douglas -Fir, No. 2 or better, Based upon either of those species and grades, with three exceptions, all ofthe exterior wall headers may be (3)-2 x 1(Ys, Notethat the garage door headers are located on the north wall which is not a primary bearing wall. Consequently, the garage door headers c9'-0" attd 16'-0" rough openings) may also be (3)- 2 x 10?s. For rough openings less Than $'-p'a the headers nmy be supported with (2)- 2 x G's (1,}ack + 1 king) each ad For rough openings 5'..0" and greater the headers may be supported with (3)-2 x 6's (2 jack -� 2 kings) each end. The three headers which are exceptions to this recommendation are located as follows: 1, The 6'-O" rough opening (sliding Wass door) at the sots ol afthe morning room. 2. The 2'4" rough opening at the north end ofthe laundry room. This header supports a girder truss, 3. The 9'-0" rough opening at the east ride of the great room. Each of these headers should be (3)-1_314" x 9, I/2°'.1t VL's (Laminated Veneer Lumber, F^b = 2600 PSI minimum), Each of the LVL headers should be supported each end with (4)- 2 x 6's (2 jacks + 2 kis. Wvoiouninu tjif y 44. la p 'fifi#Y,'y'yA+,{ i N A 4.1 I „q H2 A2 A2 R2 Al 11R li Al 0 Pct a1 Al rA 1 Al A'1 32-3-1 2 oft. ...CS ES a 0 .nc00n001 N a a a ,1 a a a 3 28-0-0 0 K O—U-0 0 •'13iF QWJcnVF s^nc rrca nlr,tf. fin'Rn 71121 nr Garfield. County Road and Bridge Department 902 Taughenbaugh Blvd., Ste 305 Rifle, CO 81650 Phone -(970)625-8601 Fax- (970)625-8627 Invoice Invoice Date: 9/11/2002 Invoice Number. 47 Bill. To: Jim Garlick ,co Driveway Permit Number $15.00 per Driveway Permit. Driveway Permit Fee: $15.00 47 f Total Due: $15.00 Thank You! itifft Garfield County Application for Drivewav Permit Application Date: 9/11/2002 PermitNurnber:47 Permitee: Jim Gornick Termination Date:10/10/2002 County Road Number: 214 Inspector: Kraig Kuberry District: 2 Sub -Contractor: Jiin Gornick hereby requests permission and authority from the Board of County Commissioners to construct a driveway approach (es) on the right-of-way off of County Road, 21.4, Approx. 1000' E. of 6070 CR 214, adjacent to Applicant's property located on the side of road for the purpose of obtaining access to property. Applicant submits herewith for the consideration and approval of the Board of County Commissioners, a sketch of the proposed installation showing all the necessary specification detail including: 1. Frontage of lot along road. 2_ Distance from centerline of road to property line. 3. Number of driveways requested 4. Width of proposed driveways and angle of approach. 5. Distance from driveway to road intersection, if any. 6. Size and shape of area separating driveways if more than one approach. 7. Setback distance of building(s) and other structure improvements. 8. No unloading of equipment on county road, any damage caused to county road will be repaired at subdivision expense. 9. Responsible for two years from the date of completion. General Provisions 1) The applicant represents all parties in interest, and affirms that the driveway approach (es) is to be constructed by him for the bona fide purpose of securing access to his property and not for the purpose of doing business or servicing vehicles on the road right of way. 2) The applicant shall furnish all labor and materials, perform all work, and pay all costs in connection with the construction of the driveway(s). All work shall be completed within thirty (30) days of the permit date. 3) The type of construction shall be as designated and/or approved by the Board of County Commissioners or their representative and all materials used shall be of satisfactory quality and subject to inspection and approval of the Board of County Commissioners or their representative. 4) The traveling public shall be protected during the installation with proper warning signs and signals and the Board of County Commissioners and their duly appointed agents and employee shall be held harmless against any action for personal injury or property damage sustained by any reason of the exercise of the Permit. 5) The Applicant shall assume responsibility for the removal or clearance of snow, ice, or sleet upon any portion of the driveway approach (es) even though deposited on the driveway(s) in the course of the County snow removal operations. 6) Tn,the event it becomes necessary to remove any right-of-way fence, the posts on either side of the entrance shall be surely braced before the fence is cut to prevent any slacking of the remaining fence, and all posts and wire removed shall be turned over to the District Road Supervisor of the Board of County Commissioners. 7) No revisions or additions shall be made to the driveway(s) or its appurtenances on the right-of-way without written permission of the Board of County Commissioners. 8) Provisions and specifications outlined herein shall apply on all roads under the jurisdiction of the Board of County Commissioners of Garfield County, Colorado, and the Specifications, set forth on the attached hereof and incorporated herein as conditions hereof. Special Conditions: 1. Minimum 30' of 18" culvert. 2. Gravel back 100'. 3. Sight distance is okay. 4. Responsible for own locates. In signing this application and upon receiving authorization and permission to install the driveway approach (es) described herein the Applicant signifies that he has read, understands and accepts the foregoing provisions and conditions and agrees to construe the driveway(s) in accordance with the accompanying specification plan reviewed and approved by the and of County Comrnissioners. Signed: Address: Ti r ornic Telephone Number: Permit granted 911112002, subject to the provisions, specifications and conditions stipulated herein. For Board of County Commissioners' of Garfield County, Colorado: Representative of Garfield County Road and Bridge Signature Special Provisions for Excavation of Road Surface and Installation 1) Any oversized material, (larger than 10 inches in diameter), that is not utilized in backfill will be hauled off by permitee. Further, any frozen material will be removed from site by pennittee. 2) When a paved or chipped surface is cut, it is to be replaced with a minimum three-inch (3") hot mix asphalt patch. Temporary patch with cold mix asphalt would be allowed, which would be replaced with hot mix asphalt when the weather or availability of materials allow the work to be completed. An asphalt or chipped surface cut would require the road to be straight cut and squared by means of a pavement cutter or saw. A chipped surface cut will require a seal coat of the patch, which will be full width or half width of roadway when trenches run with the road. For trenches across the road, the edges of the seal coat will overlap the existing edge. All seal coats will overlap edges by a two of the roadway in the vicinity of the excavation. Asphalt hot mix or cold patches will be completed in a maximum of five (5) working Days. Weather permitting. 3) When possible all installations should avoid the top edge of a fill slope. 4) Installations in drainages subject to flash flooding will have a minimum bury of 4 feet deeper than normal flow line at nearest abutment, wing wall, or culvert. 5) Installations at culvert crossings will be buried beneath the culvert with a minimum separation of 18 inches between installation and the bottom of the culvert. 6) Open trenches adjacent to the traveled roadway shall be backfilled daily to within 100 feet of the working area of the trench, and shall be barricaded with warning devices after dark. A 3 foot high orange plastic fence will be installed daily to keep livestock out of the open trench after hours. 7) In areas being disturbed where vegetation is established, reseeding with a mixture either by broadcasting, chilling and mulching with seed mixtures suitable to the climatic conditions or existing vegetation will be performed. Use only certified weed -free seed. Noxious weed control will be ongoing along with revegetation. 8) The permittee should check the R -O -W of surrounding landowners to see if other permits are required, i.e., BLM, Forest Service. Representa 1'e for arfield County Road and Bridge Jim G ick • Specifications 1. A driveway approach is understood to be that portion of the county road right -of way between the pavement edge and the property line that is designed and used for the interchange of traffic between the roadway and abutting property. 2. At any intersection, a driveway shall be restricted for a sufficient distance from the intersection to preserve the normal and safe movement of traffic. (It is recommended for rural residence entrances that a minimum intersection clearance of 50 feet be provided and for rural commercial entrances a minimum of 100 feet be provided.) 3. All entrances and exits shall be so located and constructed that vehicles approaching or using them will be able to obtain adequate sight distance in both directions along the county road in order to maneuver safely and without interfering with county road traffic. 4. The Applicant shall not be permitted to erect any sign or display material, either fixed or movable, on or extending over any portion of the county road right-of-way. 5. Generally, no more than one approach shall be allowed any parcel or property the frontage of which is less than one hundred (100) feet. Additional entrances or exits for parcels having a frontage in excess of one hundred 100) feet shall be permitted only after showing of actual convenience and necessity. 6. All driveways shall be so located that the flared portion adjacent to the traveled way will not encroach upon adjoining property. 7. No commercial driveway shall have a width greater than thirty (30) feet measured at right angles to the centerline of the driveway except as increased by permissible radii. No noncommercial driveway shall have a width greater than twenty (20) feet measured at right angles to the centerline of the driveway, except as increased by permissible radii. 8. The axis of an approach to the road may be at a right angle to the centerline of the county road and of any angle between ninety (90) degrees and sixty (60) degrees but shall not be less than sixty (60) degrees. Adjustment will be made according to the type of traffic to be served and other physical conditions. 9. The construction of parking or servicing areas on the county road right-of-way is specifically prohibited. Commercial establishments for customer vehicles should provide off -the -road parking facilities. 10. The grade of entrance and exit shall slope downward and away from the road surface at the same rate as the normal shoulder slope and for a distance equal to the width of the shoulder but in no case less than twenty (20) feet from the pavement edge. Approach grades are restricted to not more than ten percent (10%). 11. All driveways and approaches shall be so constructed that they shall not interfere with the drainage system of the street or county road. The Applicant will be required to provide, at his own expense, drainage structures at entrances and exits, which will become an integral part of the existing drainage system. The Board of County Commissioners or their representative, prior to installation, must approve the dimensions of all drainage structures. Note: This permit shall be made available at the site where and when work is being done. A work sketch or drawing of the proposed driveway(s) must accompany application. No permit will be issued without drawing, blueprint, or sketch. VTNSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED MIME JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS Ar Date Issue BUILDING PERMIT GARF1ELQ COUNTY, COLORADO fined Area Permit No.# AGREEMENT In: consideration of the issuance ofthis permit, the applicant hereby agrees to.comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector a i d IMMEDIATELY EEC f, E NULL. AND VOID. Use Address etbacks Front Side IP Side Rear This Card,Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003. 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD ACED OUTSIDE - 0\t R WITH CLEAR PLASTIC INSPECTION RECORD - Footing )__z S' --z_ i Foundation (0-31--. . Underground Plumbing 1J--/ 5'=X41— Insulation -L_l f" Rough Plumbing/ -.J -b3 /am_ Drywall Z ...g...0 ----03W- ' Chimney &Vent, Electric Final (by State Inspector) L,1.v3 'No Gas Piping g.,.-ta-013 Final .4./..../.....03 Electric Rough (By State Inspector) �_j3 ii Septic Final / tvi2 kt Framing d.- j --o3 (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - • WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. S THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003. 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD ACED OUTSIDE - 0\t R WITH CLEAR PLASTIC Job Address 7�,9 Nature of Work Use of B Owner Contractor GARFIELD COUNTY BUILDING, SANITATION, and PLANNING DEPARTMENT 109 8th, Street, Suite 303 Glenwood Springs, CO 81601(970) 945-8 2 No. 8545 Building Permit 26:1 3 -- /C1 — 03g CIerk GARFIELD COUNTY BUILDING PERMIT APPLICATION { GARFIELD COUMY (GLENWOOD SPRINGS) COLORADO TELEPHONE:: (970)945-8212 INSPECTION LNE: (970) 384-5003 PERMIT NO.•Ct PARCEL / SCHEDULE NO(;;;" 7c77 JOB ADDRESS: 0281 GOLDEN STONE DRIVE, CARBONDALE, COLORADO 81623 1. LOT NO: 34 ROARING FORK MESA ASPEN GLEN FILING 2 BLOCK NO: SUBDIVISION / EXEMPTION: ASPEN GLEN R 1 ARING FORK MESA 2.OWNER ENIS ALLDREDGE,10501 BALENTINE, OVERLAND PARK, KANSAS 66214 HM PH: WK PH: 3. CONTRACTOR -/,,f KY1 'I xra NORRIS HOMES, LLC., 5080 COUNTY ROAD 154, GLENWOOIJ SPRINGS, COLORADO 81601 ' PH: (970) 945-4400 LICENSE #: GC 01-0059 4. ARCHITECT / ENGINEER CHARLES CUNNIFTE ARCHITECTS, 610 EAST HYMAN AVENUE, SUITE 301, ASPEN, COLORADO 81611 PH: LICENSE #: C-3034 5. SQ. FT. OF BUILDING: 4,350 SQ. FT. SQ. FT. OF LOT: .372 ACRES HEIGHT: 25' NO OF FLOORS: 2 6. USE OF BUILDING: SINGLE FAMILY RESIDENCE �j, � pallet]) 4-01c(�- ., / &d2 .944 , 7. DESCRIBE WORK: NEW CONSTRUCTION UU ff JJ 8. CLASS OF WORK: NEW 0 ADDITION ❑ALTERATION 0 MOVE • REMOVE 9. GARAGE El SINGLE L✓7 DOUBLE CARPORT: ❑ SINGLE ■ DOUBLE 10. • DRIVEWAY PERMIT ■ ON SITE SEWAGE DISPOSAL / SEPTIC QS= PLAN I 1. VALUATION OF WORK: $ ADJUSTED VALUATION OF WORK: $ ir f / i/ gl Y, (s o 12. SPECIAL CONDITIONS:/ NOTICE A SEPARATE: ELEC.IRICAL PERMIT IS REQUIRED OF COLORADO. THIS PERMIT BECOMES NULL AND VOID IF WORK NOT COMMENCED WITHIN 180 DAYS AT ANY A SEPARATE: ELECTRICAL PERMIT IS REQUIRED OF COLORADO. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THE SAME TO 13E TRUE AND CORRECT. ALL PROVISIONS TYPE OF WORK WILL BE COMPLIED WITH 1 GRANTING OFA PERMIT DOES NOT PRES CANCEL SIGNATURE OWNER 1 AG T 4(�l� ?i ,1 AND MUST BE ISSUED BY THE STATE OR CONSTRUCTION AUTHORIZED IS TIME AFTER WORK IS COMMENCED. AND MUST BE ISSUED BY TITS STATE THIS APPLICATION AND KNOW AND LAWS GOVERNING THIS .• i. • SPECIFIED HEREIN OR NOT. THE GI . AUTHORITY TO VIOL . TE O • 40,40, 11 "ATE 1 t'Z' PLAN CHECK FEE: PERMIT FEE: j i y /2 4(, 54 r67l7 ,'76' TOTAL FEE: DATE PERMIT ISSUED: 314 4 , Z.9 + IOCC. GROUP: CONST. TYPE: A - 3 0-[ J V- 1 Vj I ZONING: SETBACKS BUILDING DEPT. APPROVAL - 4. Al ^ rrt -• 01, MANU: HOME: ISDS NO. & FEB:: PLANNING DEPT APPROVAL ::... ... tel/ / + //}} PERMSS[ON IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF T11E CONTRACROR OR OWNER TO CONSTRUCT THE STRUCTURE DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT. IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT. THE SIGNER HEREBY AGREES TO COMPLY W1TH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED GARFIELD COUNTY PURSUANT TO AUTHORITY IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED W1TH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF TBE ABOVE DESCRIBED STRUCTURE, THE PERMIT MAY THEN REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING DEPARTMENT OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PIANS, SPECIRCANONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION FROM BEING CARRIED ON THEREUNDER WHEN VIOIAIION OF THIS CODE OR ANY ORDINANCE OR REGULATION OF THIS JURISIDCATION Lilt REVIEW OF THE SUBIv[(i ED PLANS, SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFT ER DOES NOT CONSTITUTE AN ACCEPTANCE OF A RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY W1TH THE ARCHITECT, DESIGNER, AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE. AND IN SUPPORT OF THE OWNERS INTERESTS. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE. (INITIAL) Wei+zz i ©rrS 3- Q4 - The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road. 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water, non- absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1997 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. **** CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. 1 understand and agree to abide by the above conditions for qsain%L.si e and the issuance of a Certificate of Occupancy for the dwelling under building permit # Signature f' Date bpcont t102.-- Signature /UL VALUATION/FEE DETERM NATION .� `` .Subdivision /iic?ryrj r/(77 pI Oen F'A✓'�a ApplicantAil � �a -��r f�� � � � Address Od j ��olc�f:vt c$�oneDdve Lot/Block 3 Date `1..-} -* 02, Cttifu" k Contractor J5rr►c d me s - Finished (Livable Area): Main Upper Lower Other 6:o-/ 32,72 V 9 Total Square Feet Valuation Basement: . 4,ritii /Unfinished gizs 4 Conversion of Unfinished to Finished Plan Check Fee for Conversion Valuation Garage: Crawl Space: Valuation ( 2 qa 1 Valuation 3140 +p Decks/Patios: Covered tJ Valuation J Open Z40 Valuation . t 3240 Slid +� '40 32 Total Valuation Building Permit Fee Plan Review Fee Total BP & PR g )4 )24 .54 ZI. 9-Sb6 auoLd o to co m v n d o o m c 2 a/ 59 1 CD o 1 n ` � a SiV CDCD 7" cr 2 O fD O n .n a� o ,o g w c ro a o c: uCi 3 m 6 15 s. a ro 8` Zl.Z8-9b6 auoLld When correction(s) have been made, call for inspection. 0 c .� CD o ,• c 2 2. C fD O 0 a rt d' co a 8 3— o O zo fA O N N CL .< co N o CD O eVa.co 7eV o -I N _rt* Oc N fD � m (CL a. FIS‘ 7 N m 3. — s C 0fD a '* 0 N c 0. CL . @ 3 N o O 1 a S�. (12 p. ; N 0 fD 0. CL m 3- N 'ON 4lwaad h 'O N 3 z O e pawool qop gzc:2 la pawool qop CO" CO 52 N W. 0 1D NOT 0 N °o. .5 3. 0 0 0. 0 0" 0 00 m W w 0 3 0 .1 ID !31OD IV 0 N Q N .a 0 0 0. 0 33IiON NOI±3311l1AO 3OLLON NOIiO 1100 0 0 0 33 z "n -n rn r z rn 'D z 0 0 z 0 0 33 rn r ❑ z 0 27> m .Cathi Edinger Page 1 at 1 From: enis alldredge [ealldredge@sprynet.com] Sent: Friday, June 20, 2003 3:51 PM To: Cathi Edinger Cc: janderson@mesabank.com Subject: Certificate of occupancy for Enis Alldredge residence I hereby authorize you to provide Mesa National the original copy of the certificate of occupancy for my residence at 0281 Golden Stone, Carbondale, CO. I understand that Mesa National will pick up the certificate from you and will provide it to me later upon closing of my loan. 6/23/2003 OCT. 4.2892 11:42M ASPEN GLEN GOLF CO ASPEN GLEN GOLD COMPANY October 4, 2002 Re: REM Lot 34 Mr. Enis Alldredge 10501 Ballentine Overland Park, KS 66214 Dear Mr. Alldredge, rio.333 P.2/2 ECEIVED QCl 0 8 2002 GARFIELD COUNTY Norris Weitz builders submitted your plans to the Aspen Glen Design Review corninitte? on September 18, 2002, The revisions encompassing the addition of a walk out basement were reviewed and approved. You may proceed with acquiring a building permit from Garfield County. Please keep in mind that a copy of your approved plans are kept on file for periodic review by the Design Review Committee to assure compliance with your approved plan, Any anticipated changes from your approved plans must be submitted to, reviewed by and receive approval from the Design Review Committee prior to making any changes. Sincerely, Aspen. Glen. Design Review Committee Keith Edquist, • .., nistrator cc: DRC files Norris Weitz, Attn: Tom Doogan ASx'F.N GLEN RecuTroN Carrrrr,: 9929 STATS HIOstwAY 82 • CARBONDAL1 , CoLoitano 81623 970.963-4536. 1-800-277-4536 Aspen Glen Golf Company is an affiliate of Club Corporation of America and The Melrose Company Plans. to be included for a Building Permit, must be on drafting paper at least 18 "x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line. A section showing in detail, from the bottom of the roofing to the top of the roof, including re -bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house wrap, (which is required), siding or any approved building material. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, an 80 M.P.H. wind shear, wind exposure B, wind load of 15 pounds per square foot, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 1997 UBC, UMC and 1997 UPC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyor's signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. Yes X No 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Yes X No 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or watercourses? Yes No X 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes No X 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes X No 6. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes X No 7. Do the plans indicate the size and location of ventilation openings for the attic, roof joist space's and soffits? Yes X No 8. • Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes X ' No 9. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes X No 10. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X No 11. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes X No 12. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing (undisturbed) grade contours? Yes X No 13. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase 11 certifications or phase IT EPA certification? Yes No X 14. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No X 15. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes X No 16. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes X No 17. Do the plans indicate the Iocation of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes X No 18. Ts the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No X 19. Do you understand that if you are building on a parcel of Iand created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes X No 20. . Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes X No 21. Will this be the only residential structure on the parcel? Yes X No If no -Explain: 22. Have two (2) complete sets of construction drawings been submitted with the application? Yes X No 23. Do you understand that the minimum size a home can be on a lot is a 20ft. x 20ft.? Yes X No 24. Have you designed or had this plan designed while considering building and other construction code requirements? Yes X No 25. Does the plan accurately indicate what you intend to construct and what Will receive a final inspection by the Garfield County Building Department? Yes X No 26. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes X No 27. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building pen -nit? Yes X No 28. Are you aware that twenty-four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoons. AU inspections must be called in by 3:30 p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will delay your inspection one (1) day. Inspections are to be called in to 384-5003. Yes X No 29. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection or to receiving a Certificate of Occupancy and occupancy of the building? Yes X No 30. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project complying with the Uniform Building Code? Yes X No 31. ' Afe you aware that prior to issuance of a building permit you are required to show proof of a driveway access permit or obtain a statement from the Garfield Count y Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes X No 32. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes X No 33. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance of a building permit? Your attention in this is appreciated. Yes X No I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. S. , nature Phone: 970 -- 945 - 4400 August 21, 2002 Date (days) 970 — 945 - 4400 (evenings) Project Name: ALLDREDGE RESIDENCE Project Address: 0281 GOLDEN STONE DRIVE, CARBONDALE, COLORADO 81623 Notes: If you have answered "No" on any of the questions, you maybe required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreq 08/2002 LNont1sJ "3 HOMES A Weitz Cornpa y Aldredge Residence Final Construction Estimate Cost Code Description Base Costs Alternate Costs Square foot cost Is based on the following: Location Actual Adjusted Finished Living Areas -Main Floor ' 1,609.80 1,609.80 Finished Living Areas -Upper Floor ✓ 738.60 738.60 Exterior Covered Decks 187.00 93.50 Garage 633.80 316.90 Added areas per Alternate Main level additions 134.00 134.00 Basement 1,350.00 1,350.00 Covered Walkway at Garage 161.00 40.25 Wood Deck, ( uncovered) 268.00 67.00 Total 5,082.20 . 4,350.05 Page 1 of 1 8 October 28, 2002 Norris Homes Attn: Tom Doogan - 5080 County Road 154 Glenwood Springs, Colorado 81601 Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7985 Fax: 970-945-8454 hpgeo@hpgeotech.com Job No. 102 690 Subject: Observation of Excavation, Proposed Aldridge Residence, Lot 34, Roaring Fork Mesa at Aspen Glen, Garfield County, Colorado. Dear Mr. Doogan: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the excavation at the subject site on October 18 and 22, 2002 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. Our services were done in accordance with our agreement for geotechnical engineering services to Norris Homes, dated October 18, 2002. The proposed residence will consist of a two story wood frame structure over a basement level and crawlspace. The attached garage and basement floors will be slab - on -grade. Spread footings sized for an allowable soil bearing pressure of 2,000 psf were assumed in the design. A lateral earth pressure of 50 pcf, a coefficient of friction of 0.4 and a passive pressure of 250 pcf were assumed in the design. At the time of our initial visit to the site, the excavation was in progress and only partially completed. When observed on October 22, the foundation excavation was essentially complete and had been cut in two levels from 21 to 11 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of slightly sandy to sandy silt. On-site silt and gravel fill was observed in the western portion of the garage excavation and garage slab area. We recommended to Mike Premich with Norris that these soils be subexcavated in the footing and garage slab areas to expose the undisturbed natural soils. Results of swell -consolidation testing performed on samples of the silt taken from the site, shown on Fig. 1, indicate the soils Norris Homes October 28, 2002 Page 2 have low compressibility under existing moisture conditions and light loading and a low to moderate collapse potential (settlement under constant load) when wetted. The samples showed moderate compressibility upon increased loading after wetting. No free water was encountered in the excavation and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil and designed for an allowable soil bearing pressure of 1,200 psf can be used for support of the proposed residence. The exposed soils tend to compress when wetted and there could be post - construction foundation settlement on the order of 1 to 2 inches or more if the bearing soils become wet. The amount of settlement would depend on the depth and extent of subsurface wetting of the silt soils. Footings should be a minimum width of 20 inches for continuous walls and 2 feet for columns. Loose and disturbed soils and existing fill in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. The exposed subgrade should be moistened to near optimum and compacted prior to forming footings and placing concrete. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be heavily reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for on-site soil as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind the walls and prevent wetting of the lower level. An impervious membrane such as 20 mil PVC should be placed beneath the drain gravel in a trough shape and attached to the foundation wall with mastic to prevent wetting of the bearing soils. Structural fill placed within floor slab areas can consist of the on-site soils compacted to at least 95 % of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. Resistance to sliding at the bottoms of the footings can be calculated based on a coefficient of friction of 0.35. Passive pressure of compacted backfill against the sides of the footings should be calculated using an equivalent fluid unit weight of 300 pcf. H -P GEOTECH Norris Homes October 28, 2002 Page 3 The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. ° This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If there are any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK TECHNICAL, INC. Jordy Z. Ad. , so:` ' P. mo°l .'', .' .2.-7 02- .•' Rev. by: p tk���/O,`� NAL. JZA/rso attachment cc: Maggert & Associates - Attn: Barry Maggert H -P GEOTECH 0 1 2 3 4 0 N 5 o 6 7 8 9 10 Moisture Content = 11,5 percent Dry Density = 91 pcf —200 = 80 percent Sample of: Sandy Clayey Silt From: Bottom of Excavation, North Side 0.1 1.0 10 APPLIED PRESSURE — ksf 100 102 690 HEPWORTH—PAWLAK GEOTECHNICAL, INC. SWELL CONSOLIDATION TEST RESULTS Fig. 1 b Compression upon wetting 0.1 1.0 10 APPLIED PRESSURE — ksf 100 102 690 HEPWORTH—PAWLAK GEOTECHNICAL, INC. SWELL CONSOLIDATION TEST RESULTS Fig. 1 c 0 L CL C O 0 1 2 3 4 5 Moisture Content = 8.1 percent Dry Density = 96 pcf —200 = 58 percent Sample of: Very Sandy Silt From: Bottom of Excavation, East Side Compression upon wetting .16 i 0.1 1.0 10 APPLIED PRESSURE — ksf 100 102 690 HEPWORTH—PAWLAK GEOTECHNICAL, INC. SWELL CONSOLIDATION TEST RESULTS Fig. 2 Mbar. 7. 2003 `4"13PM Charles Cl€nniffe Architects tio.1258 P. 1/1 11111 A ARCHRECTURE PLANNING 1NTERIO 9 Chariei 1 CUnnJ1p, AIA Princlpcl Jcnver C. binlnffprt, AIA Principal March 7, 2003 Andy Schwalier Chief Building Official Garfield County 108 Sight Street, Ste. 201 Glenwood Springs, CO 81601 Via Fax: 384-3470 RE: Alldredge Residence Permit No. 8545 Dear Andy, ;; 2003 GARFIELD COUNTY WILDING & PLANNING As we discussed by phone recently, the permit drawings contained an error on sheet AO.1, General Information. Specifically, Note 13, of General Notes, calls for a fire sprinkler system to be Installed on this project. This is riot a requirement of the Garfield County Land Use Code, since the size of the house is below the threshold for mandatory fire sprinkler systems. Therefore, we respectfully request that this note be struck form the approved Building Permit Documents and voided as a requirement for this project. Thank you for your cooperation in this matter. Sincerely, Ja Pr' er a Derrington, AI cipaUGeneral Ma agar harry Streibing /Norris Homes, via fax: 945-0141 610 EAST HYMAN AVE ASPEN, CO 81611 970.925,5590 fax: 970,925.6076 IntocigcunnIffe,com www.cunnlffe,com ASPEN STEAMBOAT • TELLURIDE • VAIL INSPECTION WILL I T BE MADE UNLESS THIS CARO 15 POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issue + .) . oned Area Permit No.. 51 AGREEMENT In consideration of the issuance of this permit, theapplicant hereby agrees to comply with all caws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and IMMEDIATELY BECOME NULL AND VOID. Uses Oral LiC ', e Addres e al Desc dptio Owner # ,Crt: ontractor Setbacks ont Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing / 8 3//6 2 Foundation /7- / z -C' z 1,`%f Underground Plumbing 02-5--02, 1 .„ Insulation ' .Cr .07 Rough Plumbing d2 -a.,/-63 _ Drywall 3,,z. d)pf Chimney & Vent 3 , `Z io'30 Electric Final (by State Inspector) 1a3il) Gas Piping g__2.1 -[o3 /Gm, .. \ ll Final tel--/1"I93Plzfr Electric Rough (By State Inspector)': `le ; Septic Final Frazning2,a7 a3�,�rtad1Windims (To include Rodin place and Doors installed). Note r P.5 fFS� c. �`` 1 ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado. APPROVEDDO NOT DESTROY THIS CARD By IF PLACED OUTSIDE . 'CO '- , WITH CLEAR PLASTIC