GARFIELD COUNTY BUILDING PERMIT APPLICATION
Garfield County (Glenwood Springs) Colorado
Permit # 3c-11)
Inspection trine: (970) 384-5003
Parcel / Schedule # 2393-224-00-301
Job Address: 9.60 County Road 107, Cart r 1e. CO 81623
1.
Lo t: n/a Block q: n/a SubdlviliiorVExomption: n/a
2.
O*tw Lacerte Phi I/.'p1t Priti-
ddresa960 CR 107, Cele, CD
P"'948-0700
Wk Ph:
3
Conlractor:RiCk r llrnrCe anstr
Admoss. FC13 1055, C-dalE, m
Ph:948-6878
Lice,
4.
Architect -Engineer Jess FIEdsram.
Address: 727 (+min, C -1P, m
Ph: 704-0243
sp
Li: 83367
5.
Sq Ft of Building: 705
Sq Fl of Lor apt= 190 acrdseighl 5 of Floors 1
K_
Use of Building Residential Dwelling Unit-- / 0 r'..0q L," - R` .A4& .
7.
Describe Work: Construction of residence in existing barn
8
Class of Work. ❑ New 0 Addition et Alteration 0 Move 0 Remove
g.
Garage: 0 Sugla 0 Double Cerport: 0 Smg1e 0 Double
SO
0 Driveway Permit it On Site Sewage Disposal (Septic) IX Sile Pladig/
�Ly, / (� CID Valuation of Work $ Adjusted Valuation $: TQ 1 6, (s• CID
Specal Conditions:
Improvements Already Constructed
Special Use Permit Granted Garfield County
A SEPARATE
OF COLORADO-
THIS
S
15 NOT
SUSPENDED
IS CCOAMENCED.
1 HEREBY
THE
TYPE
THE
V10LATE
RE
NOTICE
ELECTRICAL PERMIT IS REQUIRED AND MUST BE ISSUED BY THE STATE
PERMIT BECOMES NULL O VOID IF WOW( OR CONSTRUCTION AUTHORIZED
AND
COMMENCED WHIN 150 DAYS. OR W CONSTRUCTION OR WORK is
IT
OR ABAIDONED FOR A PER100 OF 180 DAYS AT ANY TINE AFTER WORK
CERTIFY TINT 1 HAVE READ AND EXAMINED THIS APPUCATION AND KNOW
SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS GOVERNING THS
OF WORK WILL BE COMPLETED WITH WHETFC R SPECaFtED HEREIN OR NOT.
GRANTING OF THE PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO
OR CJACEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW
TING CONSTRUCTION THE PERFORMANCE OF CONSTRUCTION.
R. oatc /r 1/%4
Ran Check Fee: 367.74
^ + 1
Permit Fee: 565, -)554,5. !/� ' lnve fiGQ710„-1/+
J .
TOW Fee: 1499.24
Date Permit Issued:
— ^ I
OCC' GWDup: .i1 V
Construction Type:
V
Zoning:
Sgroase d Qrw. . AulIwlz
and lrr+aerea as • • atomSetbacks.
read
3/0,6
/ Dale
Manufactured Houle:
ex+ro+p DaPa�+� 1 Dem Flaying Department.
ISDS 4 & Fee::
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING
DEPARTMENT.
IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT, THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND
USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30 28.201 CRS AS AMENDED. THE SIGNER
FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION. ERECTION. CONSTRUCTION
AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN
661n TUG PC IT C1-1611 OGrrLAF NI n I eon Vnin
THE ISSUANCE OF A PERMIT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING
BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION
(lc THTC Il is icnrr7 on.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTORS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION REST SPECIFICALLY WITH THE ARCHITECT. DESIGNER,
o.„1 nce nI.n ,,,,,,co rnanre•rTC AOC 11.1TCMnen T, OC rf.iCCO,r.TlliC 66” 111 el Inonor r.c TUC rlls,AaCOC iuTCDeeT
GielYrn003
I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE. (INITIAL) CJ t____
r
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State Electrical Inspector,
2. Permanent address assigned by Garfield County Building Department posted where readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent
kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing;
4. A complete bathroom, with washbowl, tub or shower, toilet stool, hot and cold running water,
non-absorbent floors and walls finished and a privacy door;
5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to all 1994 UBC requirements;
6. Outside grading done to where water will detour away from the building;
7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of
extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until
all the required items are completed and a final inspection made.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE
ITEMS HAVE BEEN COMPLETED.
****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE OF OCCUPANCY
(C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE
CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING
PREMISES UNTIL ABOVE CONDITIONS ARE MET.
1 understand and agree to abide by the above conditions for occupancy, use and the issuance of a
Certificate of Occupancy for the dwelling under building permit # '361-) .
ck
--2-1 o2
Signature Date
bpcont
XcPAQLI IP
O%o C7Vo7
Cc r bo n cfa k.
*DV
44,
/ A e-,
t14; i 6 /1 l'A
* 5 '�° I
SC)-IMUEER GORDON I MEYER
ENGINEERS . SURVEYORS
December 4, 2001
Mark Bean
109 W. 8th Street
Glenwood Springs, CO 81601
Mark,
OLENw0OD SPRINGS ASPEN CRESTED BUTTE
1 1 8 w 6TU. SLATE 200 P O BOX 2 1 55 P O BO), 3088
GLENWOOD SPRIN(:9. Co 8 601 AS EN. CO 8. 812 crtErocu nuns. CO 8 1224
9!6945.1004 9709258727 970-340 5335
Fx 970945-5948 Fx 970 925 41 57 on( 970.340.5358
The purpose of this letter is to provide documentation of installation of an engineered
Individual Sewage Disposal System (ISDS) pursuant to the requirements of Garfield
County for an Accessory Dwelling Unit (ADU) at the Lacertc property 0960 CR 107,
Carbondale. It is understood that installation of the ISDS was approved without issuance
of the Special Use Permit for the ADU. The existing system capacity at the Laccrtc barn
was found to be insufficient for an ADU and it was recommended that a new drywell,
identical in dimension to the first, be placed in accordance with the attached drawings in
order to meet county ISDS requirements. ISDS installation was observed on November
30, 2001.
The original review of the system assumed the barn was a work arca only and it was
assumed that 4 workers would each use 30 gallons per day (120 gpd Design Flow). The
proposed ADU was analyzed with the assumption of 3.5 occupants each using 75 gallons
per day (262.5 gpd). The composite design flow with assumed workers and apartment
occupants is 382.5 gallons per day. This flow requires an absorption area of 726 square
feet. The effective area of the existing drywell seepage bed is 585 square feet. The
recommended placement of a second drywell of identical dimensions would increase the
total effective seepage area to 1,170 square feet. This is an area 60% greater than is
required for the proposed use.
Upon arrival at the construction site, the trench and drywell pit were open and pipes were
run from the junction box to the drywell. The drywell pit was filled with gravel to a level
of 5-6 feet with 1-1/2 inch rock. The installed pit was measured at 17'x16'. The greater
size of the pit was due to removal of large rocks in attempts to meet the 15' minimum set
forth by the drawings. No observation could be made of the base of the drywell seepage
bed as it was already backfilled with rock. The installation of the final two rings of
drywell manhole, fabric laydown, and backfill was observed. The construction of the
ISDS appeared to be in general conformance with the design drawings based upon our
spot observations.
Respectfully, 1
u
Mickey Kavlanaugh, EIT
Schmueser Gordon Meyer, Inc.
0440 ti)
Cc: Rick Lawrence, Lawrence Construction wi1>Jttt
Tod Welch, Welch Excavating
Patty Ann Lacerte
0
0
ori
0 0
W 0
ifl
(u%Y 1
1-1.1rr1
CO7.
N .7:-c
Q Z Y Q
0° O W
Ui 0 J0
W
ta. i SON
r w
C
Ll w
w
c
w U w
0 w 0
Q " w
L
0
w
W - =
Q
CO Z
N Q
Q CC 0
0 0 Z
0
'f Q
Oi
0
EXISTING SYSTEM
ro SCALE
0
CL
(0
(N
a
0 J
V) N
w
z
O
0
LFi
0
0
W
V
LJ
LTJ
Q �n U
Z
J LLJ W
L'Jw <
? >� ww
x �U LLJUJ
LJ O (J7 (n
0
W
F --
UJ
cO Z I_
N Q D
O
0 0 Z
C/) w
J
v G
z
0
0
i0
PROPOSED
NOT TO SCALE
TO DEPTH OF DR YWEL L OR 10'
PRECAST PERFORA TED
CONCRE TE DR YWEL L
RINGS
FILL WI TH ROCK TO A
DEP TH 2" ABOVE TOP OF
INLET PIPE
15.00'
1 1/2" SCREENED 1
ROCK y_
•
'
..s
GEOTEXT/LE FABRIC
CEO TEXT/LE FABRIC
MIRAF/ 140N OR EOUAL
15.00'
1
January I , 1999
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to
scale.
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with
decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line.
A section showing in detail, from the bottom of the footing to the top of the roof, including re -bar,
anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheating, house -
rap, (which is required), siding or any approved building material.
A window schedule. A door schedule.
A floor framing plan, a roof framing plan, roof must be designed to withstand a 40# per ft. up to
7,000 F.O.S. and an 80 M.P.H. wind.
All sheets to be identified by number and indexed. All of the above requirements must be met or
your plans will be returned.
1. Is a site plan included that indicates the distances of the proposed building or addition to
property lines, other buildings, setback easements and utility easements'?
Yes X
2. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System)
and the distances to property lines, wells (on subject property and adjacent properties),
streams or water courses?
Yes X See Percolation Test enclosed.
3. Does the site plan indicate the location and direction of the County or private road accessing
the property?
Yes X
4. Do the plans include a foundation plan indicating the size, location and spacing of all
reinforcing steel in accordance with the uniform building code or per stamped engineered
design?
Yes See Enclosed Engineer's Letter
5. Do the plans indicate the location and size of ventilation openings for under floor crawl
spaces and the clearances required between wood and earth?
Yes n/a
2
6. Do the plans indicate the size and location of ventilation openings for the attic, roofjoist
spaces's and soffits?
Yes See Enclosed Architect's Letter
7. Do the plans include design loads as required by Garfield County for roof snow loads, (a
minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor
loads and wind loads?
Yes See Enclosed Engineer's Letter
8. Docs the plan include a building section drawing indicating foundation, wall, floor and roof
construction?
Ycs X
9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling
joists, roof rafters or joists or trusses?
Ycs X
10. Does the building section drawing or other detail include the method of positive connection
of all columns and beams?
Yes See Enclosed Architect and Engineer Letters
11. Does the plan indicate the height of the building or proposed addition from the highest point
of the building or addition measured at mid span between the ridge and the cave down to
existing grade contours?
Yes
12. Does the plan include any stove or zero clearance fireplace planned for installation including
make and model and Colorado Phase 11 certifications or phase fl EPA certification?
Yes X No
13. Does the plan include a masonry fireplace including a fireplace section indicating design to
comply with the Uniform Building Code Chapter 37?
Yes No X
14. Does the plan include a window schedule or other verification that egress/rescue windows
from sleeping rooms and/or basements comply with the requirements of the Uniform
Building Code?
Yes X No
15. Docs the plan include a window schedule or other verification that windows provide natural
light and ventilation for all habitable rooms?
3
Yes X No
16. I)o the plans indicate the location of glazing subject to human impact such as glass doors,
glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as
a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures
and specify safety glazing for these areas?
Yes No X
17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters
indicated on the plan?
Yes No n/a
18. Do you understand that if you are building on a parcel of land created by the exemption
• process or the subdivision process, are building plans in compliance with all plat notes and/or
covenants?
Yes X No
19. Do you understand that if you belong to a homeowners association, it is your responsibility to
obtain written permission from the association, if required by that association, prior to
submitting an application for a building permit? If you do not have written permission from
the association, do you understand that the plan check fee will not be refunded should the
architectural committee deny or reject your building plans?
Yes X No
20. Will this be the only residential structure on the parcel?
Yes No X Ifno-Explain: Special Use ADU
21. Have two (2) complete sets of construction drawings been submitted with the application?
Yes X
22. Do you understand that the minimum size a home can be on a lot is a 2Oft. x 2Oft.?
Yes X No
23. Have you designed or had this plan designed while considering building and other
construction code requirements?
Yes X No
24. Does the plan accurately indicate what you intend to construct and what will receive a final
inspection by the Garfield County Building Department?
Yes X No
25. Do you understand that approval for design and/or construction changes are required prior to
4
the application of these changes?
Yes X No
26. Do you understand that the Building Department will collect a "Plan Review" fee from you at
the time of application and that you will he required to pay the "Permit Fee" as well as any
"School Impact" or "Septic System" fees required, at the time you pick up your building
permit?
Yes X No
27. Are you aware that twenty-four (24) hour notice is required for all inspections?
Inspections will be made from Battlement Mesa to West Glenwood in the mornings and
from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be
called in by 12:00 p.m. the day before; afternoon inspections must he called in by 4:00
p.m. the day before. Failure to give twenty-four (24) hour notice for inspections will
delay your inspection one (1) day. Inspections are to he called in to 384-5003.
Yes X No
28. Are you aware that you are required to call for al! inspections required under the Uniform
Building Code including approval on a final inspection prior to receiving a Certificate of
Occupancy and occupancy of the building?
Yes X No
29. Arc you aware that thc person signing the Permit Application, whether the "Owner", "Agent
of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for
the project complying with thc Uniform Building Code?
Yes X No
30. Are you aware that prior to issuance of a building permit you are required to show proof of a
driveway access permit or obtain a statement from the Garfield County Road & Bridge
Department stating one is not necessary? You can contact the Road & Bridge Department at
625-8601.
Yes X No Existing Driveway
31. Do you understand that you will be required to hire a State of Colorado Licensed Electrician
and Plumber to perform installations and hookups, unless you as the homeowner are
performing the work? The license number of the person performing the work will be
required at time of applicable inspection.
Yes X No
32. Are you aware, that on the front of the Building Permit Application you will need to fill in
the Parcel/Schedule Number for the lot you are applying for this permit on prior to issuance
of a building permit? Your attention in this is appreciated.
5
Yes X No
I hereby acknowledge that I have read, understand and answered these questions to the
best of my ability.
signature
date
Phone: (970) 945-6546 (days); (evenings)
Project Name: Laccrte Barn Apartment
Project Address:
Notes:
960 County Road 107, Carbondale, CO 81623
If you have answered "No" on any of the questions, you may be required to provide this information
at the request of the Building Official prior to beginning the plan review process. Delays in issuing
the permit are to be expected. Work may not proceed without the issuance of a permit. If it is
determined by the Building Official that additional information is necessary to review the application
and plans to determine minimum compliance with the adopted codes, the application may be placed
behind more recent applications for building permits in the review process and not reviewed until
required information has been provided and the application rotates again to first position for review,
delay in issuance of the permit or delay in proceeding with construction.
bpminreq
8/00
6
❑ Ok rough In
❑ Ok partial rou ' In
❑ Ok to pour
)2(0k final
Address a C4 1017
Date
Inspector
Inspector Phone
COLORADO STATE ELECTRICAL BOARD
1580 Logan Street, Suite 550
Denver, CO 80203-1941
BEST COPY
Garfield County Building & Planning Department
109 8th Street
Glenwood Springs; Co
I am writing on beh- of a barn structure that was built without permits located at 0960 Redhill Road
outside of Carbondalp. Pedersen Architectural Services L.L.C. has been hired by Phil Lacerate, the
er of the barn t•„i� n through the building department process, and bring the barn to compliance
.ng Codes. I will be f Iandling the issues directly related architectural codes; a
ues related to zoning and land use codes; and a structural engineer will be
0 i' directly related to the integrity of the structure. During the building process the
elec nZiaa did the electrical work on the building called for final electrical inspection which
..ssed. My involvement with the project began after the building was fully sheathed on the interior
and extconsequently, I am relying on statements of the contractor and subcontractors for
i t cannot be seen.
re+,. ua o 001, I met with Arnold from your department and we reviewed the barn and
scta`sed how I should go about addressing compliance with building codes. Amold advised me
the structure would be classified as a group S (storage) with the exception of the apartment which
would be group R-3 (residential) and there would be a one hour separation between the two. Arnold
also advised that I use your Residential Plan Review List as a guide, and respond to each applicable'
issue. 1 ha * ncluded this list with my responses along with two sets of plans representing what
was It." 111 e building complies with the building codes and was built by conventional type
V consf�uctio eaaos and methods. If you'have further questions or concerns please do not
edersen ArOftectural Services L.L.C.
•
222 Main Street
Carbondale, Colorado 81623
p 970.704.0243 ■ f 970.963.6968
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
Date Issued '.:..Zoned Area Permit No.3
00
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
described structure, the permit may then be revoked by notice from the County Building
Inspector and IMMEDIATELY BECOME NULL AND VOID.+f �`Use IVCeir t l 1� r
Address or Legal Descriptiok. (*.b OCo 1 C. (6iate
tt.„,jacer•fe t t t i l t 't 4Ci arontractor lixtkrepce QoI'k,
Front Side Side Rear
Setbacks
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
i
INSPECTION RECORD
Footing S.�ir.,- Aliv.L.A44 Q..�. 3--20-0l Wim `CESSS4S1r-1r ltrir .
i
Foundation
Underground Plumbing
Insulation
Rough Plumbing
Drywall
Chimney & Vent
Electric Final (by State Inspector) 10_07)6.4.
Gas Piping
Final 3..27.O2_ -L.S Givi-ilko Co.
Electric Rough (By State Inspector)
I
Septic Final- , , 6- 4-0 / ,114
Framing1
(To include Roof in place and
and Doors installed).
Windows
r
Notes: SU. an -at -0 �laYE% Jho,,, , irrer
44 EVc,1M zusWt-WBc
•
ALL LISTED ITEMS MIJST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 384-5003 109 8th Street County Courthouse Glenwood Springs, Colorado.
APPROVED DO NOT DESTROY THIS CARD
Dat 4144,—Bylf CE