Inspection Report
Report #1
Page 1 of 1
Dates: 6-18-15 & 7-6-15
Project: Pre -Engineered Metal Building for Gary & Leslie Jochum
Address: 594 County Rd. 110 Glenwood Springs, CO
Building Permit No.: BLRE-7-14-3314
General Contractor: American Steel
Inspection of shop fabrication or field work at job site: Field
Report: Inspected the high strength A325 bolting at main frame, end wall frame,
and column extensions for the steel frame column & rafter connections. Also
randomly tested/verified A325 bolts were adequately tightened.
In addition to the high strength bolting inspected above a visual welding
inspection was performed at the column extensions fabricated at Myers &
Company.
The high strength A325 bolting & welding inspected above appeared to be in
substantial conformance with the construction documents, and the quality
requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC
Specification for A325/A490 bolting.
To the best of my knowledge this completes the special inspections of the high
strength bolting & welding at column extensions, as outlined above.