Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108.8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970·945·8212 Fax: 970·384-3470 Inspection Line: 970-384-5003 Building Permit No. Parcel No: Job Address: 5445 County Road 154, G\enwood~~-~CO 816Q1_ _____ _ Use of Building: __ ec_x_Lpanding existing mini~storage ···--·-·-·--·--·· Owner: -·-·---·-·--··--_E~terson, Briston --------··--· Contractor: Owner Fees: Plan Check: $ 2,719.44 Septic: -·-··--·~--·---~··-·-··-··~---·· Bldg Permit: _$_ .. _.~183.75 Other Fees: ------~-- Total Fees: _$ __ 6,903.1!!__ Clerk: -C-~--Date: 5J;;;;sjd-61if I Parcel No: (this information is GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8" Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-82121 Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield-county.com AJ!l!!!l!tiJy'":!h'is application for l~~;~ie:~i:~~:·~~r~~;;,'!' described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by must be p: Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Pennits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County lSDS Permit. (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit Void Permit. A Building Permit becomes null and void if the work authori7..ed is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct I understand that the Building Departmen~ accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certifiCation as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work 1 further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facilil"y(ies) if such is in violation ~f~C~o~u~n~~~~;~~~~~~~~~~~~l~,w~.~~::~ Review of the work by the Building Department do not constitute an acceptance of responsibility or liibility by the County of errors, omissions fo<.compliru;ce with federaL state and local laws and County Regulations rest with me and my authorized agents, including without ANJXJi'rr>IlRS'f Al'ID 1'HE NOTICE & CERTIFICATJON STAFF USE ONLY Special Conditions: Adjusted Valuation: l,q 'i oti Plan Check Fee: '-1'\ Permit Fee: 'i \ 8'3 /) Manu borne Fee: Mise Fees: Total Fees: 0 qD3 1 ~ Fees Paid: Balance Due: y c;5'1 BP No & Issue Date: ISDS No & Issued Date: Kl- Setbacks: Const Type: 5-'L ~:if6 BLDG DEPT: PLNGDEPT: L. \ -o~ DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all me and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date -;P,:;e::;te:;:rse;:o~n=.,--------,..--Subdivision -";5-;,44.;.;:5:-:;C:::R::'1"'5-'4---------Lot!Block ...:4:..:/l"'/2:.:0:.::0:.::8 __________ ~Contractor Finished <Livable Area): Main Upper Lower Other Total Square Feet Valuation Basement: Unfinished Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: S-2 Valuation Total Valuation sf sf sf sf X $74.68 0 sf sf X $41.00 sf X $33.68 sf X $18.00 sf X $9.00 sf X $24.00 sf X $12.00 Commercial 17550 sf X $39.88 sf X sf X sf X sf X sf X _f_o.:r_ . ..:.:ce::....l,__'d-__ S;_:ro,..::,-=-~;_<Z..=--'-G~ c "' Owner 0.00 0.00 0.00 0.00 0.00 699,894.00 699,894.00 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended uuder a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design ProfessionaL To provide for a more understandable pIan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade 1 line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IBC, IPC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each comer of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the proposed s~re located within the envelope. Yes--\.L- 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. . /""" Yes Not necessary for this project -"V __ 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property?_../" Yes V 4. Is the LS.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? . 7 Yes . Not necessary for this project V · 2 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For ~it issuance only" or similar language? Yes ~Not necessary for this project. __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance Ith the building code or per stamped engineered design? Yes Not necessary for this project __ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes __ Not necessary for this project~ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and eart]J.:I-- Yes __ Not necessary for project_V_ 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? ~ Yes __ Not necessary for this project_V_ 10. Do the plans include design loads as required under the IBC or IRC for roof snowloads, (a minimum of 40 pounds per are foot in Garfield County)? Yes Not necessary for this project __ 11. Do the plans include design loads as required ~r loads under the IBC or IRC? Yes __ Not necessary for this project __ 12. Does the plan in e a building section drawing indicating foundation, wall, floor, and roof construction? Yes__ ot necessary for this project __ 13. Is the wind spe-~xposure design included in the plan? Yes_~_ Noo;t~ n~e~cessary for this project __ . ction drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or · sts or trusses? Yes __ Not necessary for this project __ 3 ction drawing or other detail include the method of positive connection of all columns and beam . Yes __ Not necessary for this project __ 16. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the mid oint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check ap · a le zone district for building height maximum) Yes Not necessary for this project __ 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Pba-Se1i EPA certification? Yes __ Not necessary for this project_\./""" __ 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? ./ Yes __ Not necessary for this project_\...-/"'_ 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the require~ of the IBC or IRC? Yes __ Not necessary for this project_~_ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? ~ Yes __ Not necessary for this project __ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? ./ Yes __ Not necessary for this project_~-- 22. Do the plans include a complete design for all mechanical system~ for installation in this building? Yes __ No Not necessary for this project. __ (:/=-.-·-·-·-- 4 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Ch}Pier 3) Yes _...1.LNot necessary for this project'---- 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? ./'" Yes __ Not necessary for this project_\.,./_ 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? ~ Yes __ Not necessary for this project~ 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for both sexe_? Yes __ Not necessary for this project~ 27. Do the plans indicate that restrooms and access to ti:JlX>uilding are handicapped accessible? Yes __ Not necessary for this project_~-- 28. Have two (2) co ete sets of construction drawings been submitted with the application? Yes.__.,__..-c- 29. Have you designed or h this plan designed while considering building and other construction code requirements? Yes. _ _,_~ 30. Does the plan accurat ly indicate what you intend to construct and what will receive a final inspection by the Garfield unty Building Department? Yes.__,..=. 31. Do your plans com ith all zoning rules and regulations in the County related to your zone district? For comer lots e supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Yes. __ _ 32. Do you understa at approval for design and/or construction changes are required prior to the ion of these changes? 5 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impac " ees required, at the time you pick up your building permit? Yes. -'--""""--- 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspe9ion prior to receiving a Certificate of Occupancy and occupancy of the building? Yes_~_ 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes~ 36. Are you aware that you must call iu for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and yo p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes~ 3 7. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-in~on fee? Yes~ 38. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway Permit including aN otice to Proceed; 'a permit from the federal government or any combination. You can contact t~ad & Bridge Department at 625-8601. See Phone book for other agencies Yes~ 39. Do you understand th -you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform i a lations and hookups? The license number will be required at time of inspection. Yes 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcel/ Schedule Number r the lot you are applying for this permit on prior to submittal of the building permit appli wn? Your attention in this is appreciated. Yes 41. Do you know that the al fire district may require you to submit plans for their review of fire safety issues? Yes __ (Please check with the building department about this requirement) 6 42. Do you understand that · you are planning on doing any excavating or grading to the property prior to issuance of a b · ing permit that you will be required to obtain a grading permit? Yes Not necessary for this project __ 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 10 4 of the IBC to prepare the plans and specifications for the project. Yes Not Necessary for this project ____ _ I hereby acknowledg r. ad, understand, and answered these questions to the best of my ability. Signature Date Phone: 'J~·f};9'1(days); ? t:Jt(<l~ ~~?''7 (evenings) ProjectNarne: !lk~E :S~4~~ Project Address: 5 L/ '/ ~ CtJ 1/ II/ ry Jt.& 1/P / ~· Note: On any of these questions you may be required to provide this information. If required information is not ·supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance ofthe permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, lMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. Seismic design category: B SOPSF 7001 to 8000ft. 75PSF 8001 to 9000ft. lOOPSF 9001 to lOOOOft. Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2J.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls Rvalues ai:e R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • Basement wall R-values are R-10 beTow grade, R -19 above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-1 0 below grade and R-19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R -19 insulatibn. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant /)£0£/Z-Str).J Building ~ineered Foundation -t,LDriveway Permit lf{x,e:,{i<..-/ -h,LSurveyed Site Plan +.septic Permit and Setbacks ~Grade/Topography 30% i/tt:Attach Residential Plan Review List ~inimum Application Questionnaire ~ubdivision Plat Notes ~e Department Review ~ aluation Determination/Fees __ Red Line Plans/Stamps/Sticker ~Attach Conditions ---\.,.L_Application Signed l....--1'lan Reviewer To Sign Application Aarcel!Schedule No. _J~Z,,.-40# Snow load Letter-Manf. Hms. _L Soils Report GENERAL NOTES: Date __ Lj.._-_,J'----'a'-'7...._· __ _ Planning/Zoning \./Property Line Setbacks ~Oft Stream Setbacks _Jlood Plain ~ilding Height ~ning Sign-off Jfl=Road Impact Fees 4HOA/DRC Approval __lL6rade/Topography 40% ~anning Issues ~Subdivision Plat Notes Assessor's Parcel No~395-0 I t/--oD 4 lf 'f Date 5f5i.d /0 f· i t /0'155 No._~-~----- BUILDING PERMIT CARD · JobAdd~JJs:52iLf6 Cl( 1'5~ ~~§~RV_, Cn&-!too) P~«~~ Owner(~ ~....§x> . Address;J;o)fa;x::.J3~( ~~eqJ~Ia '11.(8,·5>7] Contractor O)cv~. Address ~.,JL o.h ~hone# Cfc:l3·~ 3E£> Setbacks:. Front Rear RH LH Zoning ____ _ .._0~ ~i'<f INSPECTIONS Soils Test '-fVl ~ -~.y{ . Weatherproofing __________ _ Footing ~ a:ffc?-A-K-u Mechanical ____________ _ ,-Foundation 7-II <-0 ~ Electrical Rough (State)--------- Grout Electrical Jin~J.,(State)'--------,-,~....--Und~rground Plumbing Final ]J...;rV /Checklist C9rJ1Pieted? Mt' Rough Plumbing Certificate Occupancy# ....:N__.,· 4f:..L~...:_,_,..----- Framing Date ·7--. Insulation Septic System # __ _.N~I"-A-+. ______ _ Roofing Date ----~~--L=----- Drywall Final, ___ __;,__ _______ _ GasPiping .9~Z6-o?p~ . Otherdv~~ ~¥\l,~ 5M !>5 ~ Vr-6-rfJ;f/1?, 7-Z-o'i!> f(Zt1 NOTES I V (continue on back) COUNTY OF GARFIELD = BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 6:f/~~ c! /<g $1 Permit No. /Q-<f~Jf" s:= I have this day inspected this structure and these premises and found the following corrections needed: c;a(call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, cal! for inspection at 970-384-5003. Date 7 · f>>tJ 7 20 :c---=--- Building Inspector -~~~'-""> "'-'U~"---'-_£,-~""--------­ Phone (970) 945-8212 Division of Registrations Division of Registrations Electrical and Plumbing Permits Online View Permit 647530 Requestor Site Inspections Inspected Dale 09108t;1008 Status/Actions Company Name: R & A ENTERPRISES OF WESTERN COLO INC First Name: RICKY Last Name: BROADHURST Address: 5317 CR 154#201 City: GLENWOOD SPRINGS Stale: co Zipcode: 81601 Phone: (970) 945-6500 Fax: (970) 945-0500 . Email Address: jclark@raelectric.com Ucense Number: 3882 Property Type: PRIVATE Property Owner. H lAZY F MINI STORAGE Job SHe Address: 5445 CR 154 City: GLENWOOD SPRINGS State: CO Zipcode: 81601 County: GARFIELD . Power: HOLY CROSS-GLENWOOD SPRINGS Building Type: COMMERCIAL Construction Type: NEW Mise Construction: COMMERCIAL NEW Cost of Mate~als I Labor $: 26000 Type Status FINAL ACCEPTED Permit Number: 647530 Page 1 of2 https://www.dora.state.co.us/pls/real/ep _web _j)ermit_gui.show _j)age?p _user_ type=ELEC... 6/23/2009 Division ofRegistrations Page 2 of2 Type: ELECTRICAL status: CLOSED Opened: 06/09/2008 Expiration Date: 06109/2009 Closed: 09/09/2008 Replaces: NONE Replaced By: NONE • Questions? Check out the Definitions Page or Frequently Asked Questions (FAQ). • Please take our~ to tell us about your experience wHh the online penna& site. Generated: 0812312009 12:22 p.m. Technical Assistance· E~maillntormalion TeehnoroAY Section federal Home Page II State Home P~ II Department Home Page Top of Page E-Mail theo ~~:~~~~~!!!!!. 15608 Denver, (303) 894-2985 ~Phone (303) 894-2310 ~Fax Relay Colorado (TTY (English & Spanish), Voice, VCO, ASCil STS Assistance Numbers) https://www.dora.state.co.us/pls/realfep _web _permit_gui.show _page?p _ user_type=ELEC... 6/23/2009 HEPWORTH-PAWLAK GEOTECHNICAL February 18, 2008 HLazyF c/o Brikor Associates Attn: Briston Peterson P.O. Box 1361 Aspen, Co lorado 81612 Hepworth~ Pawlak Geotechnical, Inc. 5020 County Road !54 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Faxo 970-945-8454 email: hpgeo@hpgeotech.com Job No. 108 026A Subject: Geologic Site Review, Proposed Additions to H Lazy F Self Storage, 5445 County Road 154, Garfield County, Colorado. Dear Mr. Peterson: As requested, we have conducted a geologic site review of the subject property for feasibility of the proposed additions to the existing storage units. A field reconnaissance of the project site was conducted on February 11, 2008 to observe the site conditions. In addition, we reviewed published regional geologic studies and maps and our previous studies in the area. The review was performed in accordance with our professional services agreement with you dated January 25, 2008. The purpose of the review was to evaluate the geologic conditions at the site and assess the influence of the geology on the proposed development. A site plan of the development area was provided by High Country Engineering, Inc. dated October 31, 2007 for use in our review. We previously conducted a subsoil study for foundation design at the subject site and presented our fmdings in a report dated February 14, 2008, Job No. 108 026B. ' SITE CONDITIONS The project site is located on the valley bottom along the eastern side of the Roaring Fork River about 5 miles south of Glenwood Springs. The site is occupied by existing storage units and paved access drives. There was about Y, foot of snow cover at the time of our site reconnaissance. The aiea of the proposed additions is a graveled storage yard with vehicles and trailers. There is some fill on the property from previous site development. The ground surface slopes slightly down to the south. There is an existing 6 to 8 foot Parker 303-841-7119 & Colorado Springs 719-633-5562 • Silverthorne 970-468-1989 -2- high concrete block retaining wall supporting the west side of the existing storage. The property is located on an upper river terrace about 55 to 60 feet above the Roaring Fork River. The top of the escarpment is located just west of the west property line. Vegetation consists of sparse grass and weeds with willow trees along the property lines. GEOLOGIC SETTING The project site is located in the Roaring Fork River valley to the south of Glenwood Springs. In this area, the valley trends along the crest of the Cattle Creek anticline (Kirkham and Others, 1996). The anticline is a second-order, regional structure between the first-order Grand Hogback Monocline to the southwest and the White River Uplift to the northeast. These regional structural features developed as a result of compressional stresses during the Laramide Orogeny about 40 to 70 million years ago. In addition to the Laramide compressional stresses, the Cattle Creek anticline is also believed to be associated with ground deformations related to evaporite diapirism, hydration expansion and dissolution in the Eagle Valley Evaporite which forms the core of the anticline. Surficial deposits on the property consist of alluvial terrace deposits overlying bedrock. The alluvium locally consists of clast-supported, occasionally bouldery, pebble and cobble gravel with a sand and silt matrix. Regional geologic mapping shows that the project area is underlain by the Eagle Valley Evaporite (Kirkham and Others, 1996; and Tweto and Others, 1978). GEOLOGIC SITE ASSESSMENT The proposed additions are feasible based on the geologic conditions. The site is not impacted by flooding, snow avalanche, rockfall or debris flow. Conditions of a geologic nature that should be considered in project planning and design and are presented in this report include sinkholes, radiation potential, wetlands and earthquake considerations. Sinkholes: Sinkholes were not observed on the site during our field reconnaissance. However, the site is completely developed and any surface evidence of sinkholes has been covered up. The presence of the Eagle Valley Evaporite beneath the project area indicates that there is a potential for subsurface voids at the project site. It is our opinion that the potential for subsurface voids and sinkholes at this site is low and similar to other Job No. 108 026A -3- developments in the area. The additions can be built as proposed if the client is willing to accept a relatively low risk of future subsidence problems. Radiation Potential: The project site is not in a geologic setting that would indicate high concentrations of radioactive minerals in the near surface soils and formation rock. However, there is a potential that radon gas could be present in the area. Testing for .. radon gas levels could b~. done but is not typically :required for storage (non-living space) facilities to our knowledge, there is no regulatory maximum radon level for storage facilities. Wetlands Evaluation: In accordance with the Army Corps of Engineers (ACOE) 1987 Wetland Delineation Manual, an area must possess wetland hydrology, a prevalence of wetland vegetation and wetlands soil characteristics in order to be considered a wetland. An absence of any one of the three criteria means than an area can not be considered a wetland. Based on our site reconnaissance on February II, 2008, there are no indications of wetland soil characteristics, wetted hydrological environment or visible wetlands type vegetation. Therefore, the property does not meet the characteristics required to define the property as having wetlands. Earthquake Considerations: The project area could experience earthquake related ground shaking. Historic earthquake ground shaking in the region has been moderately strong, but has not exceeded Modified Mercalli Intensity VI (Kirkham and Rogers, 1981 ). Modified Mercalli Intensity VI ground shaking should be expected during a reasonable exposure time for the proposed residence, but the probability for stronger ground shaking is low. Intensity VI ground shaking is felt by most people and causes general alarm, but results in negligible damage to structures of good design and construction. New buildings should be desigued to withstand moderately strong ground shaking with little or no damage and not to collapse under stronger ground shaking. The region is in the 1997 Unifonn Building Code, Seismic Risk Zone I. Based on our current understanding of the earthquake potential in this part of Co lorado, we see no reason to increase the previously accepted seismic risk zone for the regiOn. Limitations: This study was conducted according to generally accepted engineering geology principles and practices in this area, at this time. We make no warranty either express or implied. The conclusions and recommendations submitted in this report are Job No. l 08 026A -4- based on our field observations, interpretations of previous geologic studies and mapping, and our experience in the area. This report has been prepared exclusively for our client to evaluate the potential influence of the geology on the development. The information is suitable for planning and preliminary design. We are not responsible for technical interpretations by others of our information. Ifyou have any questions or if we may bl:' of further assistance, plel'lse let us know. Respectfully Submitted, HEPWORTH-PAWLAK GEOTECHNICAL, INC. Rev. by: DEH JZNvad cc: High Country Engineering, Inc. -Attn: Scott Gregory REFERENCES Kirkham, R.M., and Rogers, W.P., 1981. Earthquake Potential in Colorado. Colorado Geological Survey Bulletin 43. Kirkham, Robert M., Streufort, Randall K, Hemborg, H. Thomas and Stelling, Peter L., 1996, Geologic Map of the Cattle Creek Quadrangle, Garfield County, Colorado: Colorado Geological Survey Open File Report 96-1. Tweto, Ogden and Others, 1978. Geology Map of the Leadville JO X 2" Quadrangle, Northwestern Colorado. U.S. Geological Survey Map I-999. US Army Corps of Engineers, 1987. Corps of Engineers Wetlands Delineation Manual, Wetlands Research Program Technical Report 4-87-1. Job No. I 08 026A Jeff kehr From: Sent: To: Ron Leach [leach@carbondalefire.org] Wednesday, April 30, 2008 2:03 PM Jeff Kehr Subject: FW: H Lazy F Self Storage -Verification of fire apparatus turning radius Page 1 of2 Attachments: Fire Apparatus 1 .pdf; Fire Apparatus 2.pdf; Fire Apparatus 3.pdf; 2006 7600 SBA 6x4.pdf Hi Jeff, Call me it you have any questions. Thanks, Ron Leach From: Ron Leach Sent: Wednesday, April 30, 2008 1:15PM To: Bill Gavette Subject: FW: H Lazy F Self Storage -Verification of fire apparatus turning radius From: Ron Leach Sent: Wednesday, April 30, 2008 10:09 AM To: Fred Jarman (fjarman@garfield-county.com) Cc: 'Rick Broadhurst'; 'tjs@hceng.com' Subject: FW: H Lazy F Self Storage -Verification of fire apparatus turning radius Freet I have reviewed the attached access drawings produced by Tom Scott at High Country Engineering and find the access to be acceptable to the Carbondale & Rural Fire Protection District. The fire truck that Tom used to calculate the turning radius (unit 8101) is the largest water tanker in the Carbondale fleet. All other fire trucks in the fleet have shorter turning radius and will negotiate the proposed access lanes without having to stop and negotiate the turn in more then one movement. In case of fire at the facility, the tanker (81 01 ), would be used as a water supply and would likely be parked outside the facility along County Road 154. If you have any questions, please give me a call at 963-2491. Sincerely, Ron Leach, Fire Chief Carbondale & Rural Fire Protection District From: Tom Scott [mailto:ljs@hceng.com] Sent: Friday, April 18, 2008 6:04 PM To: Ron Leach Cc: Briston Peterson Subject: H Lazy F Self Storage -Verification of fire apparatus turning radius Ron: Thank you for reviewing the H lazy F Self Storage access. As requested, we have verified that the attached turning radius exhibits conform to the attached Turning Radius Summary for the 2006 7600 SBA 6x4 (SF647) vehicle. Please contact me ifi can be of further assistance. Tom Scott 4/30/2008 10~20 10~20 10~20 f0K20 IOX20 10~20 IOx20 EXISTING RETAINING WALL 10~25 10~25 10~25 10~25 10~25 10x2:5 10~25 STORAGE COUNT !OX30: 2 !OX25: 25 !OX20: 36 !OX!O: 9 30.00 r ~ I I I I I 4.00 20.00 su feet Width 8.00 Track 8.00 Lock to Lock Time 6.00 Steering Angle 31.80 10~25 10x20 IOX25 IOX20 10x2:5 10x2:0 10x25 IOx20 !OX25 IOx20 10x25 IOx20 IOX25 10K20 10~20 10K20 IOx20 IOx20 IOx20 IOx20 IOX20 10x20 EXISTING RETAINING WALL CENTERLINE OF 10~25 IOx25 IOx25 IOX25 IOx25 IOx25 10:<25 FRAME PATH STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 10X10: 9 4.00 20.00 su Width Track Lock to Lock Time Steering Angfe feet : 8.00 8.00 6.00 : 31.80 10X25 10X20 10x25 IOX20 10x25 IOX20 IOx25 IOX20 10x25 IOx20 IOX25 10x20 IOX25 IOX20 IOX25 IOX20 IOX20 10:<20 10x20 IOxZO IOX20 10X20 EXISTING RETAINING WALL IOX25 IOX25 IOx25 JOx25 IOxZ5 IOx25 10:<25 STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 lOXlO: 9 , 19,00 ~,00 :-DO Q ~k:\~r ' 1' 3,00 1 LOO 5,00 15,00 P-8 Car Width Trailer Width Car Track Trailer Track Lock to Lock Time Steering Angle Articulating Angle feet : 7,00 : 8,00 : 6,00 : 8,00 : 6,00 : 3L60 : 70,00 IOX25 10)(2:0 IOxZ5 IOX20 IOX25 IOx20 IOx25 IOX20 10X25 10~20 IOx25 IOX20 10X25 IOX20 IOKZO IOX20 IOX2.0 IOX2.0 IOx20 IOx20 EXISTING RETAINING WALL 10~25 IOx2.5 IOX25 IOX25 IOx25 IOx25 IOx25 STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 10X10: 9 ~te;,~ 3.00 11.00 5.00 15.00 P-B Cor Width Trailer Width Cor Track Trailer Track feet : 7.00 : 8.00 : 6.00 8.00 6.00 31.60 70.00 IOX25 IOX2.0 !Ox25 IOx20 IOX25 10x20 10x25 !Ox20 10xas IOXZO !Ox25 fOX20 IOX25 !OX20 IOx20 10x20 IOx25 !OXZO !Ox25 EXISTING RETAINING WALL STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 10X10: 9 CARBONDALE Fl!<!!i Width Track Lock to Lock Time Steering Angle '8.50 '8.50 ' 6.00 '35.00 IOX25 IOX20 IOx25 IOXZO IOX25 IOX20 10X25 IOXZO IOX25 10X20 IOX25 IOX20 IOX25 10X20 IOxZ5 IOX20 IOX20 IOX20 IOx20 IOx20 IOx20 IOX20 IOX20 EXISTING RETAINING WALL IOX25 IOx25 IOx25 IOx25 IOx25 !Ox25 IOx25 STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 lOXlO: 9 CARBONDALE Flf>fii Width Track Lock to Lock Time Steering Angle : 8.50 : 8.50 : 6.00 : 35.00 IOx25 IOx20 IOx25 IOX20 IOx25 10x20 10X25 IOXZO IOx25 IOx20 IOX25 IOx20 10x25 IOX20 IOXZS IOx20 roxzo !Ox2-0 IOxlO !Ox20 IOx20 IOx20 IOX20 EXISTING RETAINING WALL !Oxl5 !Oxi?5 10X25 10X25 IOX25 !OX25 IOx25 STORAGE COUNT 10X30: 2 10X25: 25 10X20: 36 10X10: 9 CARBONDALE Fl~lii Width Track Lock to Lock Time Steering Angle '8.50 8.50 6.00 35.00 IOX25 IOX2:0 IOX25 !Ox20 !Oxl5 10X2:0 !Ox25 !OX20 IOX25 10X20 IOx25 IOx20 l0X25 IOX2:0 10X20 PRELIMINARY DRAINAGE REPORT FOR H LAZY F SELF STORAGE GLENWOOD SPRINGS, COLORADO PREPARED FOR: MHMC POBOX 185 Carbondale, CO 81623 PREPARED BY: High Country Engineering, Inc. 1517 Blake A venue, Suite lO 1 Glenwood Springs, CO 81601 (970) 945-8676 February 12, 2008 HCEJOB NUMBER: 2071762.00 TABLE OF CONTENTS SECTION I. LOCATION AND DESCRIPTION OF PROPERTY A. Property Location B. Property Description II. DRAINAGE BASINS LOCATION AND EVALUATION A. Existing Basin Description ill. DRAINAGE BASIN CRITERIA A. Regulations B. Hydrologic Criteria IV. DRAINAGE FACILITY DESIGN A. Specific Details V. CONCLUSIONS VI. REFERENCES VII APPENDIX Exhibits 1. Vicinity Map (8.5 x 11) 2. Existing Basin Map (24x36) 3. Proposed Basin Map (24x36) 4. Soils Map(SCS) Overall (11 X 17) 5. FEMA Map (11X17) 6. NOAA Map 2-yr, 24-hour (8.5x11) 7. NOAA Map 25-yr, 24-hour (8.5xll) 8. NOAA Map 100-yr, 24-hour (8.5x11) Hydrologic Computations Hydraulic Computations Details Page 2 PAGE 4 4 4 4 5 5 8 9 Engineers Certification Amber L. Gregory, P .E. Registration Number 41192 Page 3 I. LOCATION AND DESCRIPTION OF PROPERTY A. Property Location The proposed development, H Lazy F Self Storage, is located at 5445 County Road 154 in Garfield County, Colorado. The site is located north of the Roaring Fork River, south of Highway 82 and Old State Highway 82 and west of County Road 109. A vicinity map can be seen in the Exhibit 1. B. Property Description The proposed development consists of approximately 1.61 acres of partially developed land that slopes toward the southwest at 1.5-percent to 14-percent. Within the area of study, there is one soil type as designated by the United States Department of Agriculture Soil Conservation Service describes soil8, Atencio-Azeltine Complex, as having 1-3 percent slopes. This soil is deep and well drained with a low water capacity and is defined as hydrologic group 'B'. A brief description of the soil has been included on the soils map. See Exhibit #2 for specific information. The soil that encompasses the proposed site is soil8. The majority of the proposed development is delineated as Zone C from the Flood Insurance Rate Map, Community Panel #0802051465B, dated January 3, 1986. Zone Cis defined as areas of minimal flooding per the FEMA map (refer to Exhibit 5 in the appendices). The northern portion of the proposed site is located within Zone A, which is defined as areas of 1 00-year flood per the FEMA map discussed above. Refer to the appendices for mapping and debris flow information provided by the study. II. DRAINAGE BASINS LOCATION AND EVALUATION A. Existing Basin Description Storm water discharge from Old US Highway 82 is captured in a roadside swale and routed north and does not enter the site. A negligible amount of runoff enters the site from the property to the north of the site before draining west and offsite. III. DRAINAGE BASIN CRITERIA A. Regulations The Soil Conservation Services (SCS) TR-55 Tabular method was utilized for this report for onsite and offsite runoff to remain consistent with Garfield County standards. The proposed development's hydraulic structures shall be sized for the 25-year storm event and the development shall safely convey the 1 00-year storm; therefore, this report analyzes the 25 and 1 00-year storm events for this proposed development. National Oceanic and Atmospheric Administration (NOAA) maps were used for the rainfall intensities for the storm events. Please see exhibits 6-8 for NOAA maps Page4 B. Hydrologic Criteria The proposed development's hydraulic criterion was broken down in to gravel areas, buildings and asphaltic pavement categories. The combinations of gravel, asphalt and buildings were input in to the TR-55 composite runoff coefficient calculator to determine specific runoff coefficients for each basin. The SCS Hydrology function in AutoCAD was used to determine the size of the drywells during the 25-year and 100-year storm events. AutoCAD's pipe calculator was used to determine if the increase in the 25-year runoff from the site to the existing storm water pipes would be within the pipe's capacity. The existing soil conditions for the site can be seen in Exhibit 4 and the calculations can be seen in the appendices. IV. DRAINAGE FACILITY DESIGN A. Specific Details The existing site consists of two storage unit buildings, an asphalt area, gravel area, and open space. The runoff from the eastern portion of the site will be captured in existing area inlets. The storm water is then routed northeast and offsite to the existing roadside ditch. The runoff from the mid portion of the site, between the two existing storage buildings is captured in two area inlets before being routed offsite via 12-inch CMP storm sewer pipes. The gravel area and the western half ofthe western-most storage building drains west and southwest and offsite. The existing site has been broken down in to five separate drainage basins. Basin EX-1 is located in the northern and northwestern portion of the site and consists of asphalt, gravel and a portion of the western storage building. Basin EX-1 drains southwest and offsite. Basin EX-2 is located south ofbasin EX-1, in the south-western comer of the site. Basin EX-2 consists of gravel and a portion of the western storage building. Existing basin EX-3 is located east of basin EX-2, in the central portion of the site and consists of asphalt, gravel and portions ofboth storage buildings. The runoff from basin EX-3 drains to an existing area inlet before being routed offsite via an 12-inch storm pipe. Existing basin EX -4 is located north of existing basin EX-3 and consists of asphalt and portions of both storage buildings. The runoff from basin EX -4 drains to an area inlet before being routed offsite via a 12-inch storm pipe. Basin EX -5 is located along the eastern half of the site and consists of open space, asphalt and the eastern half of the eastern-most storage unit. The runoff from basin EX-5 drains to an existing area inlet before being routed offsite via a 12-inch storm pipe. Refer to Exhibit 2 in the appendices for the existing basin delineation and characteristics. Table 1, below, is a summary of the existing basin characteristics. More detailed information can be seen in the appendices. Table I Existing Basin Characteristics BASIN AREA, CN Tc(MIN) 025-YEAR. CFS 0100-YEAR· ACRES CFS EX-1 0.49 87 5.00 0.81 1.06 EX-2 0.26 86 5.00 0.39 0.53 EX-3 0.22 93 5.00 0.53 0.66 EX-4 0.26 98 5.00 0.81 0.97 EX-5 0.39 98 9.48 0.96 1.16 TOTAL 3.50 4.38 Page 5 The proposed development calls for the construction of72 additional storage units, an asphalt parking/driving area, gravel, and drywells. The proposed site was designed to carry the 25-year storm event to proposed drywells located along the western property boundary. The site has been broken down into eight proposed onsite basins. Basin PR-1 is located in the northwest comer of the site and consists of asphalt and gravel. The runoff from proposed basin PR-1 direct discharges as sheet flow to the northwest comer of the site and offsite. Proposed basin PR-2 is located below basin PR-1, along the western property boundary. Proposed basin PR-2 consists of gravel, asphalt and storage units. The runoff from proposed basin PR-2 is routed south to proposed drywell number one. Proposed basin PR-3 is located to east of proposed basin PR -2 and consists of asphalt and storage units. The runoff from proposed basin PR-3 is captured in a 2-foot diameter area inlet before being routed to proposed drywell number one via a 12-inch storm pipe. Proposed basin PR -4 is located south of proposed basin PR-3 and consists of gravel, asphalt and storage units. The runoff from proposed basin PR-4 sheet flows to a proposed 2-foot diameter area inlet before being routed to proposed drywell number 2, which is located in the southwestern comer of the site. The runoff captured in the area inlet will be transferred to the drywell via a 12-inch storm drain pipe. Proposed basin PR- 5 is located south of proposed basin PR-4, in the southwestern comer of the site and consists of gravel, asphalt and storage units. The runoff from proposed basin PR-5 sheet flows to proposed drywell number two. Proposed basin PR-6 is located to the east of proposed basin PR -5 and consists of gravel, asphalt and storage units. The runoff from proposed basin PR-6 is routed north to an existing area inlet. The runoff is captured in the existing inlet before being routed off site via an existing 12-inch CMP storm pipe. Proposed basin PR-7 is located north of proposed basin PR -6 and consists of existing asphalt, existing storage units and proposed asphalt and proposed storage units. The runoff from proposed basin PR-7 is captured in an existing area inlet before being routed offsite via an existing 12-inch CMP storm drain pipe. Proposed basin PR-8 is located south of proposed basin PR-8 and consists of storage units and gravel. The runoff from proposed basin PR-8 direct discharges as sheet flow west and offsite. The proposed construction will not affect existing basin EX-5. Table 2, below, shows a summary of the proposed basins. More detailed information can be seen in the appendices. T bl 2P a e ropose dB . S asm Uffiffiar:' BASIN AREA, CN Tc(MIN) Ozs-YEAR• CFS 0100-YEAR, ACRES CFS PR-1 0.04 95.0 5.00 0.10 0.13 PR-2 0.14 97.0 5.00 0.41 0.50 PR-3 0.19 98.0 5.00 0.59 0.71 PR-4 0.10 98.0 5.00 0.31 0.37 PR-5 0.13 96.0 5.00 0.36 0.44 PR-6 0.23 97.0 5.00 0.67 0.82 PR-7 0.38 98.0 5.00 1.18 1.42 PR-8 0.02 98.0 5.00 0.06 O.D7 TOTAL 3.68 4.46 This proposed development has a net increase in runoff from the site due to the increased imperviousness. The required drywell volume spreadsheet in Microsoft Excel was used to determine the 25-year storage volume for both drywells. Drywell number one was sized to handle the increase in runoff from proposed basins PR-2, PR-3 from existing basin EX-1. Page 6 Proposed drywell number two was sized for the increase in runoff from proposed basins PR-4 and PR-5 from existing basin EX-2. The direct discharge from the other three proposed basins is below the existing runoff from the site. The volume was determined to be 1,260 cubic feet of storage for drywell number one and 1,008 cubic feet for drywell number two. The required volumes were input into the Microsoft Excel spreadsheet for drywell sizing to determine the diameter and depth ofthe drywells and the required width of gravel around each drywell. The required size for drywell number one was determined to be 4-feet in diameter and 12-feet deep with 9.5-feet of gravel around the drywell. The required size for drywell number two was determined to be 4-feet in diameter and 12-feet deep with 8.5-feet of gravel around the drywell. The calculations can be seen in the appendices. The proposed storm drain pipes were sized using AutoCAD's Hydrology program. The two existing 12-inch storm pipes were also analyzed to determine if the next increase in runoff to the two pipes would be above the pipes' capacities. The calculations can be seen in the appendices. Page7 V. CONCLUSIONS This drainage report has been designed per the Garfield County standards and regulations. The proposed drainage facilities will adequately convey the storm water from the proposed site offsite before being discharged into the Roaring Fork River. Detention in the proposed drywells has been provided to account for the increased runoff. Page 8 VI. References National Oceanic and Atmospheric Administration: Precipitation-Frequency Atlas of the Western United States, Volume ill-Colorado. Silver Springs, MD 1973. United States Department of Agriculture, Soil Conservation Service: Soil Survey of Aspen- Gypsum Area, Colorado, Parts of Eagle, Garfield, and Pitkin Counties, May 1992. United States Department of Agriculture, Soil Conservation Service: Urban Hydrology for Small Watersheds, June 1986. Soil Conservation Service (SCS) publication "Procedures for Determining Peak Flows in Colorado" (1980) Page9 EXHIBITS SOILS DESCRIPTION: 8. ATENCIO-AZELTINE COMPLEX, HAVING 1-3 PERCENT SLOPES. THIS SOIL IS DEEP AND WELL DRAINED WITH A LOW TO VERY LOW WATER CAPACITY AND MODERATE TO NA TIOHAL.FLOOO INSURANCE PROGRAM FLOOD INSURANCE RATE MAP KEY TO MAP Flood Boundary----- . Flood Boundary .>ignations GARFIELD COUNTY, COLORADO (UNINCORPORATED AREAS) Flood Boundary----- Flood Boundary----- >d Elevation line ~ation In f cet:t:* ---513-~- (EL 987i P.I\NEL1465 OF 1900. )d Elevation in Feet liform Within Zone** (SEE MAP !NOEX FOR PANELS NOT PRINTED) MARK RM16 RM17 RM18 RM19 RM42 RM44 Reference Mark RM7x ioundary--------- e •M1.5 need to the National Geodetic Vertical Datum of 1929 . 'LANATION OF ZONE DESIGNATIONS COMMUNITY ·PANEL NUMBER 0802051465 8 EXPLANATION MAP REVISED: Areas of 100-year floodj base flood elevations and flood hazard factors not determined. JANUARY 3, 1986 Special Flood Hazard Areas inundated by types of 1 00-year shallow flooding where depths are between 1.0 and 3.0 feet; depths are shown, or areas of 1 00- year alluvial fan ffooding,,depths and velocities shown, but no flood hazard factors arc determined. ElEVATION (FT.NGVD) 5898.98 5942.86 6025.31 5961.30 6002.67 5957.45 ELEVATION REFERENCE MARKS DESCRIPTION OF LOCATI< U.S. Army Corps of Engineers: benchmark d "X'• on the top of the southwest abutment of tl bridge over the Roaring Fork Fliver near C1 U.S. Army Corps of Engineers b<!nehrnark ct spike in a cottonwood tree 60 feet west of thEi and 190 feet north of a bafbwire fente rufln north cod of a pond. U.S. Geological Survey disk stampod "N 158 · post 57 feet northwest of Denver and Rio Gran Areas of 1 00-year shallow flooding where depths are between one (1) and three (3) feet; base flood elevations are shown, but no flood hazard factors are determined. Areas of 1 00-year flood; base flood elevations, and flood hazard factors determined. Areas of 100-year flood to be protected by flood protection system under construction; base flood elevations and flood hazard factors not determined. Areas between limits of the 100-year flood and 500- year flood; or certain areas subject to 1 OO~year flood~ ing with average depths less than one ( 1} foot or where the contributing drainage area is less than one square mile; or areas protected by levees from the base fiood. (Medium shading) mile post 368, 15 feet northwest of a foad c1 Areas of minimal flooding. {No shading) southwest of the main track centerline west of ( u.s. Army Corps of Engineers benchmark C( Areas of undetermined, but possible, flood hazards. spike in a power pole 225 feat north of a ranel Areas of 1 OO~year coastal flood with velocity (wave east CQrner of Sec 12• T. 7 s., R. 89 w. ICattl action); base flood elevations and flood hazard factors Sheet). not determined. Brass cap in cOflCrete", located 7 miles $oUth o· and on east side of County Road 109. Esta! Areas of 100~year coastal flood with velocity (wave county. action}; base flood elevations and flood hazard factors u.s. Coast and Geodetic Survey brass eap i determined. · · 4.8 miles southeast along Denver and Rio Gran'· ftom Glenwood Courthouse. at northeast corrl tion Center Tot. NOTES TO USER ~as no~ in the special flood hazard areas {zones A and V) ~ >tecte<J by flood control structures. · ~s for flood insurance purposes onl~; it does not neces~ ll-----1 · H all areas subject to flooding in the community or PROJEcrNo. 11 GRAPHIC SCALE ~ •.. r itric features outside special flood hazard areas. i i T T . - ( IN F"EE1' ) I lneb "' 1000 fl .. iing m<!.p panels, see separately prialted Index To Map 2071762..00 5 APPENDIX A HYDROLOGIC COMPUTATIONS SUMMARY EXISTING CONDITIONS EX-1, 25 YR H LAZY F SELF 2071762.00 2-12-08 EX-1, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . EX-1, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.4900 ac 726.0000 min 0.8050 cfs subarea D/S subareas Area (ac) CN TC (min) Tt Rainfall Description (min) (in) EX-1 0.4900 87 5.0000 0.0000 support Data: subarea Name: EX-1, Row: 1 sheet Flow Description ..•.................. Manning's n . . .. .. .. .. .. .. .. .. .. . 0.0110 Flow Length .. .. .. . . .. . . . . . . . . . . . 226.6000 ft Two vr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope...................... 0.0507 ft/ft computed sheet flow time ....................... > 2.6241 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 2.6241 min **************************** composite Runoff curve Number calculator Description ASPHALT GRAVEL Total Area -----> Area (ac) 0.0700 0.4200 0.4900 curve Number 98 85 87 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 EX-1, 100YR H LAZY F SELF STORAGE 2071762.00 2-12-08 EX-1, 100 YR TR-55 Tabular Hydrograph Method Input Summary Description .................... . EX-1, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Type II On 0.4900 ac 726.0000 min 1.0646 cfs subarea D/S subareas Area CN Tc Tt Ra i nfa 11 Description (ac) (min) (min) (in) -------------------------------------------------------------------------------EX-1 0.4900 87 5.0000 0.0000 2.6000 support Data: Subarea Name: EX-1, Row: 1 sheet Flow Description .................... . Manning's n . . . .. . . . . . . . . . . .. . . . . 0.0110 Flow Length . . . . . . . . . . . . . . . . . . . . . 226.6000 ft Two vr, 24 hr Rainfall . . . . . . . . . . 1.2000 in Land Slope...................... 0.0507 ft/ft computed sheet flow time ....................... > 2.6241 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 2.6241 min **************************** Composite Runoff curve Number Calculator Description ASPHALT GRAVEL Total Area -----> Area (ac) 0.0700 0.4200 0.4900 curve Number 98 85 87 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 EX-2, 25 YR H LAZY F SELF 2071762.00 2-12-08 EX-2, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . EX-2, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.2600 ac 726.0000 min 0.3938 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) EX-2 0. 2600 86 5.0000 0.0000 Support Data: subarea Name: EX-2, Row: 1 sheet Flow Desc ri pti on .................... . Manning's n .. .. . .. .. .. .. .. .. . .. . 0.0110 Flow Length . . . . . . . . . . . . . .. . .. . .. 81.0500 ft Two Yr, 24 hr Rainfall .. ...... .. 1.2000 in Land Slope...................... 0.0225 ft/ft computed sheet flow time ....................... > 1.5955 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 1.5955 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area Messages: -----> Area (ac) 0.0200 0.4200 0.4400 curve Number 98 85 86 <-----Weighted CN Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 EX-2, 100 YR H LAZY F SELF STORAGE 2071762.00 2-12-08 EX-2, 100 YR TR-55 Tabular Hydrograph Input summary Description .................... . EX-2, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tot a 1 Area ..................... . Peak Time ...................... . Peak FlOW •.••.•................. Given Input Data: Method Type II on 0. 2600 ac 726.0000 min 0. 5268 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) EX-2 0.2600 86 5.0000 0.0000 Support Data: subarea Name: EX-2, Row: 1 sheet Flow Description ..•.....••.....•.•..• Manning's n . . . .. . . . . . . . . . .. . . . . . 0.0110 Flow Length • • . • • • • • • . . . . . . • . . . . . 81.0500 ft Two vr, 24 hr Rai nfa 11 • • . • • • • . . . 1. 2000 in Land slope . . . . . . . . . . • . . . . . . . . . . • 0.0225 ft/ft computed Sheet flow time ..............•••••.••. > 1.5955 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 1. 5955 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.0200 0.4200 0.4400 curve Number 98 85 86 <-----Weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 EX-3, 25 YR H LAZY F SELF 2071762.00 2-12-08 EX-3, 25 YR STORAGE TR-55 Tabular Hydrograph Input Summary Description .................... . EX-3, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...........•........... Given Input Data: Method Type II on 0.2200 ac 726.0000 min 0.5284 cfs Subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) ---------------------~-~-------------------------------------------------------EX-3 0.2200 93 5.0000 0.0000 2.2000 Support Data: subarea Name: EX-3, Row: 1 Sheet Flow oescri pti on ........•............ Manning's n .. .. . .. . .. . .. .. .. .. .. 0.0110 Flow Length .. . . .. . . . . . . . . . . . . . . . 110. 9000 ft Two Yr, 24 hr Rainfall .. . .. .. . .. 1.2000 in Land slope...................... 0.0908 ft/ft computed sheet flow time ....................... > 1.1735 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 1.1735 min **************************** Composite Runoff Curve Number Calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1400 0.0800 0.2200 curve Number 98 85 93 <-----Weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 EX-3, 100 YR H LAZY F SELF 2071762.00 2-12-08 EX-3, 100 YR STORAGE TR-55 Tabular Hydrograph Input: summary Descri pt:i on .................... . EX-3, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tot: a 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input: Data: Method Type II on 0.2200 ac 726.0000 min 0.6590 cfs Subarea D/S subareas Area CN Tc Tt: Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------EX-3 0.2200 93 5.0000 0.0000 2.6000 Support Data: subarea Name: EX-3, Row: 1 Sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length . . . . . . . . . . . . . . . . . . . • . 110. 9000 ft Two vr, 24 hr Rainfall . . . . . . . .. . 1.2000 in Land slope . . . . . . . . . . . . . . . . . . . . . . 0.0908 ft:/ft computed sheet: flow time .................•..... > 1.1735 min Messages: Info: Time of concentration rounded t:o 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 1.1735 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Messages: Area (ac) 0.1400 0.0800 0. 2200 curve Number 98 85 93 <-----Weighted CN Info: Time of Concentration rounded to 6.0000 min in row <1>. Page 1 EX-4, 25 YR H LAZY F SELF STORAGE 2071762.00 2-12-08 EX-4, 25 YR TR-55 Tabular Hydrograph Input summary Description .................... . EX-4, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ............... , ..... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II On 0. 2600 ac 726.0000 min 0.8094 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) EX-4 0.2600 98 5.0000 0.0000 support Data: subarea Name: EX-4, Row: 1 Sheet Flow Description ..•...•.••.••••..•. , . Manning's n .. .. .. . ... . . . .. . . . .. . 0.0110 Flow Length • .. • .. .. . . . .. . . . . . . . . 145.0400 ft Two Yr, 24 hr Rainfall .•. • . . . . .. 1.2000 in Land Slope .. .. .. . . . • . . • . .. .. . .. . 0.0103 ft/ft computed Sheet flow time ........•.•....•....... > 3.4740 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 3.4740 min **************************** Composite Runoff curve Number Calculator Description ASPHALT/BLDG GRAVEL Total Area Messages: Info: Time of -----> Area (ac) 0.1400 0.0800 0.2200 curve Number 98 85 93 <-----weighted CN Concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 EX-4, 100 YR H LAZY F SELF 2071762.00 2-12-08 EX-4, 100 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . EX-4, 100 YR Rainfall Di stri buti on .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.2600 ac 726.0000 min 0.9725 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) EX-4 0. 2600 98 5.0000 0.0000 support Data: subarea Name: EX-4, Row: 1 Sheet Flow Description .................... . Manning's n . .. . .. .. .. .... .... .. . 0.0110 Flow Length . .. . .. .. .. .. .. .. .. .. . 145.0400 ft Two Yr, 24 hr Rainfall .. .. . .. . .. 1.2000 in Land slope...................... 0.0103 ft/ft computed Sheet flow time ....................... > 3.4740 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 3.4740 min **************************** Composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area Messages: -----> Area (ac) 0.1400 0.0800 0.2200 curve Number 98 85 93 <-----weighted CN Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 EX-5, 25 YR H LAZY F SELF 2071762.00 2-12-08 EX-5, 25 YR STORAGE TR-55 Tabular Hydrograph Input Summary Des c ri pti on .................... . EX-5, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tota 1 Area ..................... . Peak Time ...................... . Peak FlOW ...................... . Given Input Data: Method Type II on 0.3900 ac 732.0000 min 0.9617 cfs Subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------EX-5 0. 3900 98 9. 4800 0.0000 2. 2000 support Data: subarea Name: EX-5, Row: 1 sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length..................... 265.2300 ft Two Yr, 24 hr Rainfall ... .. .. .. . 1.2000 in Land Slope ...................... 0.0028 ft/ft computed sheet flow time ....................... > 9.4800 min Messages: Info: Time of Concentration rounded to 12.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 9.4800 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1400 0.0800 0.2200 curve Number 98 85 93 <-----Weighted CN Messages: Info: Time of concentration rounded to 12.0000 min in row <1>. Page 1 EX-5, 100YR H LAZY F SELF STORAGE 2071762.00 2-12-08 EX-5, 100 YR TR-55 Tabular Hydrograph Input summary Description .................... . EX-5, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ..... , ....... . Tota 1 Area ..................... . Peak Time ...................... . Peak Flow ....•......•......•.... Given Input Data: Method Type II on 0. 3900 ac 732.0000 min 1.1555 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) EX-5 0. 3900 98 9.4800 0.0000 support Data: subarea Name: EX-5, Row: 1 sheet Flow Description ....•..............•. Manning's n • . • . . .. • . . • .. .. .. • .. . 0.0110 Flow Length .. .. . .. .. .. . .. . . • .. • . 265.2300 ft Two Yr, 24 hr Rainfall ......•... 1.2000 in Land slope . . • . . . . . . . . .. . . . . .. . . . 0. 0028 ft/ft Computed sheet flow time .•....•...•.•....••...• > 9.4800 min Messages: Info: Time of concentration rounded to 12.0000 min in row <1>. *************************** Total Time of concentration .......•...........•..... > 9.4800 min **************************** composite Runoff curve Number Calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1400 0.0800 0.2200 curve Number 98 85 93 <-----weighted CN Messages: Info: Time of concentration rounded to 12.0000 min in row <1>. Page 1 2.6000 PROPOSED CONDITIONS PR-1, 25YR H LAZY F SELF 2071762.00 2-12-08 PR-1, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary oescription .................... . PR-1, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tot a 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type 1I on 0.0400 ac 726.0000 min 0.1042 cfs subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------PR-1 0. 0400 95 5.0000 0.0000 2. 2000 Support Data: subarea Name: PR-1, Row: 1 Sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length . . . . . . • . • • . . . . . . . . . . . 78.0500 ft TWO Yri 24 hr Rainfall • . . . . . . . . . 1.2000 in Land s ope . . . . . . . . . . . . . . . . . . . . . . 0. 0200 ft/ft computed Sheet flow time ....................... > 1.6228 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. *************************** Total Time of concentration ......................... > 1.6228 min **************************•* composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Area (ac) curve Number Total Area -----> Messages: 0.0300 0.0100 0.0400 98 85 95 <-----Weighted CN Info: Time of concentration rounded to 6.0000 min warning: Runoff coef < 30. 30 used in row <%d>. Page 1 in row <1>. H LAZY F SELF 2071762.00 2-12-08 PR-1, 100 YR STORAGE TR-55 Tabular Hydrograph Input Summary Description ...................•. PR-1, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ....................•.. Peak FlOW ..........•..••........ Given Input Data: tmp#14 Method Type II on 0.0400 ac 726.0000 min 0.1285 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-1 0.0400 95 5.0000 0.0000 Support Data: subarea Name: PR-1, Row: 1 Sheet Flow Description •.••••.••.•.......... Manning's n .. . . .. .. . .. . . .. .. ... • 0.0110 Flow Length . . . . • • . • • • . • • • . • • .. .. 78, 0 500 ft Two vr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope • • • . . • . . • . . . . • • . . . . . . . 0.0200 ft/ft Computed Sheet flow time •..••••..•.....•....... > 1.6228 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. *************************** Total Time of Concentration ......................... > 1.6228 min **************************** Composite Runoff Curve Number Calculator Description ASPHALT/BLDG GRAVEL Area (ac) curve Number Total Area -----> 0.0300 0.0100 0.0400 98 85 95 <-----Weighted CN Messages: Info: Time of concentration rounded to 6.0000 min warning: Runoff coef < 30. 30 used in row <%d>. Page 1 in row <1>. 2.6000 PR-2, 25YR H LAZY F SELF 2071762.00 2-12-08 PR-2, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-2, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tota 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II On 0.1400 ac 726.0000 min 0.4143 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) PR-2 0.1400 97 5.0000 0.0000 support Data: subarea Name: PR-2, Row: 1 sheet Flow Description ....................• Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length . . . . . . . . . . . . . . . . . . . . . 20. 0000 ft Two Yr, 24 hr Rainfall . . . . . . . . . . 1.2000 in Land Slope ...................... 0.1000 ft/ft computed Sheet flow time ....................... > 0.2868 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0. 0110 Flow Length ..................... 137.5500 ft TWO Yr, 24 hr Rainfall .......... 1.2000 in Land slope . . . . . . . . . . . . . . . . . . . . . . 0.0188 ft/ft computed Sheet flow time ....................... > 2.6174 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 2.9042 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1300 0.0100 0.1400 curve Number 98 85 97 <-----Weighted CN Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 PR-2, 100YR H LAZY F SELF STORAGE 2071762.00 2-12-08 PR-2, 100 YR TR-55 Tabular Hydrograph Input summary Description .................... . PR-2, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tota 1 Area .....................• Peak Time ...................... . Peak Flow .........•........•.... Given Input Data: Method Type II on 0.1400 ac 726.0000 min 0. 5015 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-2 0.1400 97 5.0000 0.0000 support Data: Subarea Name: PR-2, Row: 1 sheet Flow Description ....•.•..•••••••.••.. Manning's n • . • . . •• . . . . . . . .. .. . . . 0.0110 Flow Length . . . . • . . • • . . . . . . . . • . . . 20. 0000 ft TWo Yr, 24 hr Rainfall . .. . • . • . . • 1.2000 in Land Slope . . • . . . . . . . • . • . . • . . . . . . 0.1000 ft/ft Computed sheet flow time ............••••...•••• > 0.2868 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. Sheet Flow Description ...................•. Manning's n . . . . . . • . . • . . . . . • . . . . . 0. 0110 Flow Length • . • . . . . . . . . . . . . . . . . . • 137. 5 500 ft Two Yr, 24 hr Rainfall • . . • . • .. . . 1.2000 in Land Slope . . . . . . . . . . . . • . . . . . . . . . 0.0188 ft/ft computed sheet flow time .........•.....•....... > 2.6174 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 2.9042 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1300 0.0100 0.1400 curve Number 98 85 97 <-----Weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 PR-3, 25YR H LAZY F SELF STORAGE 2071762.00 2-12-08 PR-3, 25 YR TR-55 Tabular Hydrograph Input summary Description ....... , ............ . PR-3, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................•... Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.1900 ac 726.0000 min 0. 5915 cfs Subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-3 0.1900 98 5.0000 0.0000 Support Data: subarea Name: PR-3, Row: 1 sheet Flow Description .................... . Manning's n .. . .. .. .. . .. . ..... .. . 0.0110 FlOW Length .. .. .. . .. .. .. .. .. .. .. 95.6900 ft ''rwo Yr, 24 hr Rainfall . . . .. .. . . . 1.2000 in Land slope...................... 0.0148 ft/ft Computed sheet flow time ....................... > 2.1546 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Tota 1 Time of Concentration ......................... > 2.1546 min **************************** Composite Runoff curve Number Calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1900 0.0000 0.1900 curve Number 98 85 98 <-----Weighted CN Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 PR-3, 100YR H LAZY F SELF 2071762.00 2-12-08 PR-3, 100 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-3, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ............•.......... Peak Flow ........•.....••....... Given Input Data: Method Type II on 0.1900 ac 726.0000 min 0. 7107 cfs Subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-3 0.1900 98 5.0000 0.0000 Support Data: subarea Name: PR-3, Row: 1 Sheet Flow Description ..•.................. Manning • s n • . • . . . • . . . . . • . • . • . • • • 0. 0110 Flow Length • . . . . • • • • . • . • . . • • • • • • 9 5 • 6900 ft TWo Yr, 24 hr Rainfall • • . . • . . • . . 1.2000 in Land Slope . . . .. • . . . . . . . . . .. . .. . . 0.0148 ft/ft Co~puted Sheet flow time •.•.....•..••...•.•...• > 2.1546 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 2.1546 min **************************** Compos1te Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1900 0.0000 0.1900 curve Number 98 85 98 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 PR-4, 25 YR H LAZY F SELF 2011762.00 2-12-08 PR-4, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description •........•........... PR-4, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ................•..... Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.1000 ac 726.0000 min 0.3113 cfs Subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-4 0.1000 98 5.0000 0.0000 support Data: subarea Name: PR-4, Row: 1 sheet Flow Description .•..•••••••••.••..••• Manning's n • • • • • • • . • • . . • . . • . . . . . 0.0110 Flow Length • • .. • .. .. • • . . • . . .. . . • 20. 0000 ft Two Yr, 24 hr Rai nfa 11 . .. . . . .. . . 1. 2000 in Land Slope • .. .. • .. .. . .. .. .. .. .. . 0.1000 ft/ft __ ,~omputed sheet flow time ....................... > 0.2868 min lllfessagl!$: - Info: Time of concentration rounded to 6.0000 min in row <1>. Sheet Flow Description .........••.•.•...... Manning's n .. .. .. .. .. .. .. .. .. .. . 0.0110 Flow Length .. .. .. .. .. .. • .. .. .. .. 83.1600 ft Two Yr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope • .. • . . . . . . . • . . . . . . . . . . 0.0142 ft/ft computed sheet flow time ....................... > 1.9579 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ......................... > 2.2447 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Messages: Area (ac) 0.1900 0.0000 0.1900 curve Number 98 85 98 <-----Weighted CN Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 PR-4, 100 YR H LAZY F SELF STORAGE 2071762.00 2-12-08 PR-4, 100 YR TR-55 Tabular Hydrograph Input Summary Description .................... . PR-4, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tota 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.1000 ac 726.0000 min 0.3740 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) PR-4 0.1000 98 5.0000 0.0000 Support Data: subarea Name: PR-4, Row: 1 Sheet Flow ----:>------Description .................... . Manning's n . . . . .• . . .. ... . . .. . . . . 0.0110 Flow Length .. .. .. . .. .. .. .. .. .. .. 20. 0000 ft Two vr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope...................... 0.1000 ft/ft computed Sheet flow time ....................... > 0.2868 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length .. .. .. .. .. .. .. .. .. .. . 83.1600 ft Two vr, 24 hr Rainfall . . . . . . . . . . 1.2000 in Land Slope . . . . . . . .. . .. . . . . . . . .. . 0. 0142 ft/ft Computed Sheet flow time ....................... > 1.9579 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 2.2447 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Messages: Area (ac) 0.1900 0.0000 0.1900 curve Number 98 85 98 <-----weighted CN Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 PR-5, 25 YR H LAZY F SELF 2071762.00 2-12-08 PR-5, 25 YR STORAGE TR-55 Tabular Hydrograph Input Summary Description .................... . PR-5, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area .....•................ Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.1300 ac 726.0000 min 0. 3628 cfs subarea D/S subareas Area (a c) CN TC (min) Tt Rainfall Description (min) (in) PR-5 0.1300 96 5.0000 0.0000 Support Data: Subarea Name: PR-5, Row: 1 sheet Flow Description ................•...• Manning's n .. .. .. .. .. .. .. • .. .. .. 0.0110 Flow Length .. .. .. .. .. • .. .. .. . .. . 2 5 . 0000 ft Two Yr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope .. .. .. . .. .. .. .. .. .. . .. 0.1000 ft/ft computed sheet flow time ............•........•. > 0.3429 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. sheet Flow Description ................•.... Manning's n . . . . . . . . • . . . . . . . . . . . . 0.0110 Flow Length .. • .. . . . • • . . . . . .. • . • . 120.6300 ft Two Yr, 24 hr Rainfall .•..•.•.•. 1.2000 in Land Slope .. .. .. . .. . . .. .. . .. . .. . 0.0101 ft/ft Computed Sheet flow time ......•.......•........ > 3.0214 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 3.3643 min **************************** Composite Runoff Curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area Messages: Info: Time of -----> Area (ac) 0.1100 0.0200 0.1300 curve Number 98 85 96 <-----weighted CN concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 PR-5, 100 YR H LAZY F SELF 2071762.00 2-12-08 PR-5, 100 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-5, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tot a 1 Area ..................... . Peak Time ...................... . Peak FlOW ...................... . Given Input Data: Method Type II on 0.1300 ac 726.0000 min 0.4430 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) PR-5 0.1300 96 5.0000 0.0000 Support Data: subarea Name: PR-5, Row: 1 Sheet Flow Description .................•... Manning's n . . . . .. . ... .. . .. .. .. .. 0.0110 Flow Length ..................... 25.0000 ft Two vr, 24 hr Rainfall . . . . . . . . . . 1.2000 in Land slope .. . . .. . . . . . . . . . . . . .. .. 0.1000 ft/ft computed Sheet flow time ....................... > 0.3429 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . .. . 0.0110 Flow Length .. .. .. . .. . .. . .. .. .. .. 120.6300 ft Two Yr, 24 hr Rainfall .. .. .. .. .. 1.2000 in Land slope . . . . . . . . . . . .. . . . . . .. . . 0.0101 ft/ft computed sheet flow time ....................... > 3.0214 min Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 3.3643 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.1100 0.0200 0.1300 Messages: Info: Time of concentration rounded to Page curve Number 98 85 96 <-----weighted CN 6.0000 min in row <1>. 1 2.6000 PR-6, 25 YR H LAZY F SELF 2071762.00 2-12-08 PR-6, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description ..•.................. PR-6, 25 YR Rainfall Distribution .•......... Ia/P Interpolation ............. . Total Area ............•......... Peak Time ....•....•....•.•...... Peak Flow •.•.•.•........•.....•. Given Input Data: Method Type II on 0.2300 ac 726.0000 min 0.6732 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) PR-6 0.2300 97 5.0000 0.0000 Support Data: subarea Name: PR-6, Row: 1 Sheet Flow Description .....•••.•.•.•.•..... Manning's n . . • • . • . • . • . . . • . . . . . • . 0.0110 Flow Length • • . • . • • • . • • . . . . . . . . • . 110. 9000 ft Two Yr, 24 hr Rainfall . •••.•• •• • 1.2000 in Land slope ..•........•.......... 0.0937 ft/ft computed Sheet flow time .•...........•..••••••. > 1.1588 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ..........•.............. > 1.1588 min **************************** Composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0. 2100 0.0200 0.2300 curve Number 98 85 97 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.2000 PR-6, 100 YR H LAZY F SELF 207176e.OO 2-12-08 PR-6, 100 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-6, 100 YR Rainfall Distribution ...•....... Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.2300 ac 726.0000 min 0.8162 cfs subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------PR-6 0.2300 97 5.0000 0.0000 2.6000 Support Data: subarea Name: PR-6, Row: 1 Sheet Flow _,..._ ______ , Description ............•........ Manning's n • . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length . . . . . . . . . . . . . . . . . . . . . 110. 9000 ft TWo vr, 24 hr Rainfall . . . • • • . . . . 1.2000 in Land Slope . . . . . . . . . . . . . . . . . . . . . . 0.0937 ft/ft computed Sheet flow time ..••.................•. > 1.1588 min Messages: Irifo: Time of Concentration rounded to 6.0000 min in row <1>. *************************** Tot a 1 Time of concentration ......................... > 1. 1588 min **************************** Composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0. 2100 0.0200 0.2300 Curve Number 98 85 97 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 PR-7, 25 YR H LAZY F SELF 2071762.00 2-12-08 PR-7, 25 YR STORAGE TR-55 Tabular Hydrograph Input Summary Description .................... . PR-7, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tot a 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II On 0. 3800 ac 726.0000 min 1.1830 cfs ------------------------------------------------------------------~------------subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------PR-7 0.3800 98 5.0000 0.0000 2.2000 support Data: subarea Name: PR-7, Row: 1 sheet Flow oescri pti on ............•........ Manning's n . .. . . . . . ... . . . . . . .. . . 0.0110 Flow Length . . . . . . . . . . . . . . . . . . . • . 201.6500 ft Two vr, 24 hr Rainfall ...•...... 1.2000 in Land slope . . . . . . . . . . . . . . . . . . . . . . 0.0529 ft/ft Computed Sheet flow time ....................... > 2.3500 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of Concentration ......................... > 2.3500 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.2100 0.0200 0.2300 curve Number 98 85 97 <-----Weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 PR-7, 100 YR H LAZY F SELF 207176.2.00 2-12-08 PR-7, 100 YR STORAGE TR-55 Tabular Hydrograph Input Summary Description ...........•......... PR-7, 100 YR Rainfall Distribution .......... . Ia/P Interpolation .....•........ Total Area ..................... . Peak Time .......•............... Peak FlOW ......•......•......... Given Input Data: Method Type II On 0. 3800 ac 726.0000 min 1.4214 cfs subarea D/S subareas Area (a c) CN Tc (min) Tt Rainfall Description (min) (in) PR-7 0.3800 98 5.0000 0.0000 Support Data: subarea Name: PR-7, Row: 1 Sheet Flow ':"---------Description ....•..•••.••........ Manning's n • •• • • • •• • • ... . . •.• • .• 0.0110 Flow Length • • . . • • . . . • . . . • . • • . . • • 201.6500 ft Two Yr, 24 hr Rainfall • • • • • • . . . . 1.2000 in Land Slope . • . • . . . • • • • • • . • . • . . . . . 0.0529 ft/ft Computed Sheet flow time ....••••............... > 2.3500 min Messages: rnfo: Time of concentration rounded to 6.0000 min in row <1>. *************************** Total Time of concentration ............•......•..... > 2. 3 500 min **************************** Composite Runoff curve Number Calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.2100 0.0200 0.2300 curve Number 98 85 97 <-----weighted CN Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. Page 1 2.6000 PR-8, 25 YR H LAZY F SELF 2071762.00 2-12-08 PR-8, 25 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-8, 25 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Total Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II on 0.0200 ac 726.0000 min 0.0623 cfs -----------~-------------------------------------------------------------------subarea D/S subareas Area CN Tc Tt Rainfall Description (ac) (min) (min) (in) -------------------------------------------------------------------------------PR-8 0.0200 98 5.0000 0.0000 2.2000 Support Data: subarea Name: PR-8, Row: 1 sheet Flow Description .................... . Manning's n . . . . . . . . .. . . . . . . . .. . . 0.0110 Flow Length . . . . . . . . . . . . . . . . • . . . . 15.0000 ft Two Yr, 24 hr Rainfall .......... 1.2000 in Land slope . . . . . . . . . . . . . . . . . . . . . . 0.1000 ft/ft computed sheet flow time ....................... > 0.2278 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. sheet Flow Description .................... . Manning's n . . . . . . . . . . . . . . . . . . • . . 0.0110 Flow Length .. .. .. .. .. .. .. .. .. .. . 15.0000 ft Two Yr, 24 hr Rainfall .. . . .. .. .. 1.2000 in Land slope .. .. .. .. .. .. .. . .. .. .. . 0.0200 ft/ft Computed sheet flow time ....................... > 0.4337 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. *************************** Total Time of concentration ......................... > 0.6615 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.2100 0.0200 0.2300 curve Number Page 1 98 85 97 <-----Weighted CN PR-8, 25 YR Messages: Info: Time of Concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. Page 2 PR-8, 100 YR H LAZY F SELF 2071762.00 2-12-08 PR-8, 100 YR STORAGE TR-55 Tabular Hydrograph Input summary Description .................... . PR-8, 100 YR Rainfall Distribution .......... . Ia/P Interpolation ............. . Tota 1 Area ..................... . Peak Time ...................... . Peak Flow ...................... . Given Input Data: Method Type II On 0.0200 ac 726.0000 min 0.0748 cfs subarea D/S subareas Area CN Tc Tt Rai nfa 11 Description (ac) (min) (min) (in) ----------~------------~------------------------------------------------------- PR-8 0.0200 98 5.0000 0.0000 2.6000 support Data: Subarea Name: PR-8, Row: 1 sheet Flow Desc ri pti on .................... . Manning's n . . . . . . . . . . . . . . . . . . . . . 0.0110 Flow Length .. .. . .. .. . . .. .. . .. . .. 15.0000 ft Two Yr, 24 hr Rainfall .. .... .. .. 1.2000 in Land slope .. . .. .. ... .. ... . .. . . . . 0.1000 ft/ft computed sheet flow time ....................... > 0.2278 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. sheet Flow Description .................... . Manning's n .. . .. .. . .. .. .... .. . .. 0.0110 Flow Length . . .. .. .. .. .. .. .. .. .. . 15.0000 ft Two Yr, 24 hr Rainfall . . . . . . . . . . 1.2000 in Land Slope .. . .. . . . . . . . . . . . . . . . . . 0.0200 ft/ft Computed sheet flow time ....................... > 0.4337 min Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. *************************** Total Time of Concentration ......................... > 0.6615 min **************************** composite Runoff curve Number calculator Description ASPHALT/BLDG GRAVEL Total Area -----> Area (ac) 0.2100 0.0200 0.2300 curve Number Page 1 98 85 97 <-----weighted CN PR-8, 100 YR Messages: Info: Time of concentration rounded to 6.0000 min in row <1>. warning: Runoff coef < 30. 30 used in row <%d>. Page 2 APPENDIXB HYDRAULIC CALCULTIONS PR-6, 100 YR PIPE H LAZY F SELF STORAGE 2071762,00 2-12-08 PR-6 100 YR PIPE TO EXISTING AREA INLET IN EX-3 Manning Pipe calculator Given Input oata: shape , .......•..•.........•..... solving for ...........•..•...... Diameter ....................... . Flow rate ....................... . s 1 ope .......................... . Manning's n .............•....•.. Computed Results: Depth .......................... . Area ........................... . wetted Area .....•••............. wetted Perimeter •••..••.......•. Perimeter ...•................... velocity ..•..................... Hydraulic Radius ......•...•..... Percent Full ................... . Full flow Flowrate ............. . Full flow velocity ............. . Circular Depth of Flow 12.0000 in 0.8200 cfs 0.0050 ft/ft 0.0200 6.0053 in 0.7854 ft2 0.3931 ft2 18.8602 in 37.6991 in 2.0858 fps 3.0017 in 50.0443 % 1.6375 cfs 2.0850 fps Page 1 PR-7, 100 YR PIPE H LAZY F SELF STORAGE 2071762.00 2-12-08 PR-7, 100 YR TO EXISTING AREA INLET IN BASIN EX-4 Manning Pipe calculator Given Input Data: shape ..........•.........•...... Solving for .•...•..•............ Diameter ....................... . Flow rate ........•............... s 1 ope .......................... . Manning's n •..•.....•.•.•....... Computed Results: Depth ...•....................... Area .......•.•..............•... Wetted Area •..•.............•.•. wetted Perimeter ..•.•........... Perimeter .•..•.................. velocity •....................... Hydraulic Radius ......•...•..... Percent Full ................... . Full flow Flowrate ......•....... Full flow velocity .........•.... Circular Depth of Flow 12.0000 in 1.4200 cfs 0.0050 ft/ft 0.0200 8.6334 in 0.7854 ft2 0.6049 ft2 24.3021 in 37.6991 in 2.3475 fps 3.5842 in 71.9452 % 1.6375 cfs . 2.0850 fps critical Information critical depth ••••.••...•.....•. critical slope ................. . critical velocity ......•........ Cri ti ca 1 area ..•...•.....•.••..• cri ti ca 1 peri meter •••••••.•.•.•. critical hydraulic radius ••..... cri ti ca 1 top width .•......••..•. Specific energy •.••.•••••••••••• Minimum energy •••••.•••••••••.•• Froude number ..••..•............ Flow condition ........•.•....•.• 6.0528 in 0.0146 ft/ft 3.5759 fps 0.3971 ft2 18.9552 in 3.0167 in 12.0000 in 0.7944 ft 0.7566 ft 0.5385 subcri ti ca 1 Page 1 Variables Volume to Width of Depth of gravel Detain (cf) Gravel (ft) Below MH (ft) 1260.0 9.5 2 of M.H. (sqft) 12.6 of Gravel ( sqft) 402.9 4 0.0 0.0 31.4 5 0.0 0.0 31.4 6 0.0 0.0 31.4 7 831.0 332.4 31.4 8 1233.9 493.5 31.4 9 1636.8 654.7 31.4 10 2039.7 815.9 31.4 11 2442.6 977.0 31.4 12 2845.5 1138.2 31.4 13 3248.4 1299.4 31.4 Note: Gravel depth ~egins 6.0' below 1517 BLAKE A VENUE Glenwood Springs. CO 8160 I Tele: • Fax 945-2555 Dia of M.H. 4 12.6 25.1 37.7 50.3 62.8 75.4. 88.0 100.5 113.1 125.7 Percent Voids(%) 40 Volume 44.0 44.0 56.5 56.5 69.1 69.1 81.7 414.1 94.2 587.8 106.8 761.5 119.4 935.3 131.9 1109.0 144.5 1282.7 157.1 1456.4 shall be at least 1 0' deep. 14 Inverness Drive East Suite F~120 Englewood. CO 80 1!2 Tele: 925-0544 ·Fax 925·0547 -·-· Met no no no no no no no no no Meets Min. Meets Min. H LAZY F SELF STORAGE HCE JOB# 2071762.00 February 12, 2008 EX-1 VS PR-1, PR-2, PR-3, PR-8 DRY WELL SIZING EXISTING VERSUS PROPOSED V,=(Oz-O,)(T) V,=Runoff volume (cubic feet) Q 1=Existing runoff, cubic feet per second (Q=CIA for a calculated Tc) Q2=Proposed runoff, cubic feet per second (Q=CIA for a calculated T c) T=60 minutes rainfall duration (3600 seconds) Q,= 0.81 Q2= 1.16 T= 3600 Vr= 1260 Required Percolation area of the drywell Ap"' (V,)I(K)(43,200) Ap = Total area of the sides of the percolation area, square feet V, = Runoff volume, cubic feet K = Hydraulic conductivity of soil, feet/second 1260 0.000024 1215.28 Volume to Detain (cf) 1008.0 of M.H. (sqft) 12.6 of Gravel (sqft) 333.8 Gravel 4 0.0 5 0.0 6 0.0 7 692.7 8 1026.5 9 1360.3 10 1694.1 11 2027.9 12 2361.7 1517 BLAKE A VENUE Glenwood Springs, CO 8160 I Tele: • Fax 945-2555 Variables Width of Depth of gravel Gravel (ft) Below M.H. (ft) 8.5 2 I Voids Conic Section 0.0 31.4 0.0 31.4 0.0 31.4 277.1 31.4 410.6 31.4 544.1 31.4 677.6 31.4 811.2 31.4 944.7 31.4 Diaof M.H. 4 Cyl. Section 12.6 25.1 37.7 50.3 62.8 75.4 88.0 100.5 113.1 Percent Voids(%) 40 Drywall Volume 44.0 44.0 56.5 56.5 69.1 69.1 81.7 358.8 94.2 504.9 106.8 650.9 119.4 797.0 131.9 943.1 144.5 1089.2 14 Inverness Drive East Suite F~120 Englewood, CO 80112 Tele: Met no no no no no no no no no Meets Min. HLAZYFSELFSTORAGE HCE JOB# 2071762.00 February 12, 2008 PR-4, PR-5 VS EX-2 DRYWELL SIZING EXISTING VERSUS PROPOSED V,=(Q,..O,)(f) V,=Runoff volume (cubic feet) Q 1=Existing runoff, cubic feet per second (Q=CIA for a calculated Tc) Q2=Proposed runoff, cubic feet per second (Q=CIA for a calculated T c) T=60 minutes rainfall duration (3600 seconds) o,= 0.39 Q2= 0.67 T= 3600 V,= 1008 Required Percolation area of the drvwell Ap = (V,)/(K)(43,200). Ap = Total area of the sides of the percolation area, square feet V,= Runoff volume, cubic feet K = Hydraunc conductMiy of soil, feet/second 1008 0.000024 972.22 j® ® ~@ @ ® @ @ 0J ® ® ·-. ® ® ® ® @ @ ® ) ® OlfOi:! 773,<i:/O:J @ ® ® ® ® ® ~~® !;' . 'b3~"-3 ') \";J\')'b)'f\ ® 'b3~~3 ® . "' . ® ® ®® ® ·O -~ Parcel Detail Page 1 of3 Garfield County Assessor/Treasurer Parcel Detail Information AssessmLILe~asurer Pro~ Search I Assessor SubsetQym I Assessor Sales s.~arch Clerk &.Reqprder Reception S~em:<:h Parcel Detail I Value Detail I Sale~Detail I Residential/Commercial ImprovemenLD~etllil L.amLPetail I Photographs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 011 II R111490 II 239501400114 II 60.843 I Owner Name and Mailing Address !PETERSON, BRlSTON & !PITKIN EXCHANGE HOLDINGS OF ASPEN LLC 1601 E HOPKINS !ASPEN, CO 81611 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:l-7-89 DESC: A TR IN !LOTS 20 & 21 AKA PARCEL 2 DESC: !AMENDED STOWE EXEMPTION PLAT IPRE:R111484 BK:0640 PG:0295 BK:0639 IPG:0901 RECPT:739526 RECPT:729519 IBK:0755 PG:0952 BK:0755 PG:0954 Location I I I I I I I Physical Address: 115445 154 COUNTY RD GLENWOOD SPRINGS! I Subdivision: I I Land Acres: I 1.61 I Land Sq Ft: I 0 I Section II Townshi~ II Range I II II http://www.garcoact.com/assessor/Parcel.asp? AccountNumber=R111490 3/18/2008. Parcel Detail Page 2 of3 II I 7 89 II 2007 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 596,11011 172,8701 I Improvements: II 500,92011 145,2701 I Total: II 1,097,03011 318,1401 Sale Date: 1112/17/2007 Sale Price: 111,700,000 Basic Building Characteristics Number of Residential 0 Buildings: Number of Commllnd 2 Buildings: I Commercial/Industrial Building Occurrence 1 Characteristics I TOTAL HEATED AREA: 0 ABSTRACT CODE: lw AREHOUSE/STORAGE-IMPS. ARCHITECTURAL STYLE: IMINISTORG EXTERIOR WALL: ICASTCONCR EXTERIOR WALL: IcON BLOCK I ROOF COVER: IIBUILT-UP I ROOF STRUCTURE: IIFLAT INTERIOR WALL: IIUNFINISHED INTERIOR WALL: IIMINIMUM FLOOR: IIcoN oN GRD HEATING FUEL: IINONE I HEATING TYPE: IINONE I STORIES: STORIES 2.0 I BATHS: 0 ROOMS: I UNITS: 54 BEDROOMS: I 0 YEAR BUILT: 111984 I http://www.garcoact.com/assessor/Parcel.asp? AccountNumber=Rlll490 3/18/2008