Loading...
HomeMy WebLinkAboutInsulation Certificate 10.2015Builders Statement CertainTeed SAINT GOBAIN InsulSafe®SP Fiber Glass Blowing Insulation Homeowner Name / Jobsite Name (Llc.f/ MM -4-65 Home Address �3 /2-111C2 V/ T4 61(.Z nNnld a T, 5-tv/Li.A1GAS' , Installer / Contractor (sign) Company Name Date /SJL.A« Le_ Jo -5 /5 Builder (sign) Company Name Dale Inspected By (sign it required) OPEN ATTIC APPLICATION Date R•VALUE MINIMUM BAGS PER 1000 SO. FT. MAXIMUM NET SO. FT. PER BAG COVERAGE MINIMUM WEIGHT- POUNDS PER SO. FT. MINIMUM INSTALLED THICKNESS MINIMUM SETTLED THICKNESS To obtain a thermal resistance (R) of Bags per 1000 sq. it 01 net area: Contents of bag shall not cover more than: (sq It I Weight per sq tt. of installed insulation shall not be less than. (lbs) Installed insulation shall not be Tess than: (in.) Minimum seated insulation shall not be less than, (in.) 60 31.4 31.9 0.972 22.00 22.00 49 25.2 39 7 0 780 18.50 18.50 44 22.4 44.6 0 695 16.75 16.75 38 19.1 52.5 0 591 14.50 14.50 30 14.9 67.1 0 462 11.75 11.75 26 12.8 77.9 0 398 10.25 10.25 22 _ 10.8 92.9 0 334 815 8.75 19 9.3 107.4 0.289 775 7.75 13 6.2 161.7 0 192 5 25 5.25 11 5 3 190.5 0 163 4 50 4.50 THERMAL PERFORMANCE -ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R -Value listed. • The maximum net coverage must not exceed that specified for each R -Value. • The insulation must be installed at or above the specified installed thickness for each R -Value. • Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R -Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES -TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. CEILINGS A- 3 8 1 r iq• Soil 1 300 F. ,:,, a 5 WALLS 2-z I 5 IZ LI /9-1 8 sf, aa - a -FLOORS FLOORS THERMAL PERFORMANCE -ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number of bags per 1,000 sq. ft. of net area for each R -Value listed. • The maximum net coverage must not exceed that specified for each R -Value. • The insulation must be installed at or above the specified installed thickness for each R -Value. • Failure to install the required minimum weight per sq. ft. of insulation at or above the initial installed thickness will result in reduced R -Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES -TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. THIS WARNING DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. Manufacturer Insulation Fact Sheet InsulSafe SP Fiber Glass Blowing Insulation COVERAGE CHART -OPEN ATTIC APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application. 11-VALUEMINIMUM BAGS PER 1000 SO. FT. MAXIMUM NET SO. FT. PER BAG COVERAGE MINIMUM WEIGHT- POUNDS PER SO. FT. MINIMUM INSTALLED THICKNESS' MINIMUM SETTLED THICKNESS To obtain a thermal res stance: (R) of Bags per 1000 F. fi of net area. Contents of bag shall not cover more than. (sq. K.) Weight per sq ft of installed insulation shall not be less than: (lbs) Installed insulation shall not be fess than: (in.) Minimum settled insulation shall not be less Than: (in.) 60 31.4 31.9 0 972 22.00 22.00 49 25 7 39.7 0 780 18.50 18.50 44 22.4 44 6 0 695 16.75 16.75 38 19.1 52.5 0 591 14.50 14.50 30 149 67.1 0 462 11.75 11.75 26 12 r1 77.9 0.398 10.25 10.25 22 10 9 92 9 0 334 8.75 8.75 19 9 3 107.4 0 289 7.75 7.75 13 6.2 161.7 0192 5.25 5.25 11 5.3 190.5 0 163 450 4 50 K Values are determined in 'rccordance with ASTM C687 and C518. Complies with ASTM C764 as Type 1 pncumati Application. 'Initial Installed Thickness testing per ASTM C13'4 using Unisul Vo"utsi.aic III; 3rd gear. 14 -'.rich gate 15pc+ning. 150 ft. x 3.1/2 -inch diameter internally corrugated blot. hose, 12. to 1.5doot arc length. COVERAGE CHART -CLOSED CAVITY RETROFIT (WALLS, FLOORS, CEILINGS) APPLICATION The following thermal performances are achieved at the thicknesses, weights and coverages specified when insulation is installed with pneumatic equipment in sidewalls. Based on a design density of 1.6 pcf/25.6 Kg/m'. R -VALUE REQUIRED OR MINIMUM BAGS PER 1000 SO. FT. MAXIMUM NET SO. FT. PER BAG COVERAGE MINIMUM WEIGHT- POUNDS PER SO. FT. INSTALLED THICKNESS To obtain a thermal resistance lR' cf. Bags per 1000 sqft of net area. Contents oI bag shall not cover more Than: (sq. It.) Weight per sq ft.:" nstallcd insulation shal not be less than: Ilbs.) Installed insulation shall not be Tess than' (in.) 29 31.2 32.1 0.967 725 22 23 7 42.3 0.733 5.50 16 17.2 58 1 0 533 4.00 15 16.1 62 S 0 500 3.75 14 15 1 65 4 0 467 3,50 READ THIS BEFORE YOU BUY What you should know about R -Values. The chart shows the R -Value of this insulation. R means resistance to heat flow. The higher the R -Value, the greater the insulating power. Compare insulation R -Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R -Value, it is essential that this insulation be installed properly. ©Seal and Insulate with ENERGY STAR LUX,' IPRE AT n.rgy.ar go. NAIMA REENGUARD' Ma•er u.0+wrr c..an.a 4 ENERGY STAR AWARD 2010 PARTNER OFTHEYEAR ASK ABOUT OUR OTHER CERTAINTEED PRODUCTS AND SYSTEMS: EXTERIOR: ROOFING • SIDING • WINDOWS • FENCE • RAILING • TRIM • DECKING • FOUNDATIONS • PIPE INTERIOR: INSULATION • GYPSUM • CEILINGS CertalnTeed Corporation P.O. Box 860 Valley Forge, PA 19482 Professional: 800-233-8990 Consumer. 800-782-8777 www.certainteed.com/insulation Code No 30-24-298, 02/11 Carta nTeed Corporation CertainTeed SAINT GOBAIN Silich Homes 303 AABC Suite J Aspen Co 81611 INSULATION CERTIFICATE PROJECT: Lot # 257 — 203 River Vista GWS Post Office Box 2888 Vail, Colorado 81658 970-524-3000 Fax 970-524-3001 October, 2015 SPECIFICATIONS: R38 fiberglass loose fill insulation to truss exterior ceiling areas at house main & upper levels Perimeter baffles to truss exterior ceiling areas at house for proper venting 4 mil poly vapor barrier to house truss exterior ceilings R21 unfaced fiberglass baits to house 2x6 exterior wall areas R21 unfaced fiberglass batts at house to garage 2x6 partition walls 4 mil poly vapor barrier to exterior walls of house R38 unfaced fiberglass batts to garage ceiling to conditioned space above 4 mil vapor barrier to garage ceiling to conditioned space R21 unfaced batts to exterior rim joist areas at main level Foam to windows and doors for proper thermal and air sealing Fire Rated Foam to mechanical penetrations as per Garfield county code R38 fiberglass loose fill insulation with 6 mil poly to garage exterior ceiling R21 unfaced fiberglass baits to garage 2x6 exterior walls with 6 mil poly 1