Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Spring$, Co. 81601 Office:970·945-8212 Fax: 970-384-3470 Inspection Line: 970-384-5003 Building Permit No. Parcel No: 2179-013-00-677 --- Locality: -~--Ke~ll~~ Michael L~nEamily LLC Exe!llption Lot 4 _ __ 50_1 CR_~~jjf __ _ Job Address: ------~----- Use of Building: ~~-Detached Garag,_e __ _ Owner: Kevin Contractor: Owner Fees: Plan Check: 154.21 Septic: Bldg Permit: 237.25 Other Fees: -------- Total Fees: $ 391.46 Clerk: ~ Date: Lo~~tSQ_ I 1 2 3 GARFIELD COUNTY BillLDING PERMIT APPLICATION 108 8'" Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www. garfield-county.com Parcel No: (this information is available at the assessors office 970-945-9134) 2-11'1 0\3 00011 Job s~;esr ~i~l::ess~a;;ot ~~igned, ple~~r~~e Cr~ og-}~t 5-;: City) or and legal description Lot No: Block No: Subd.l Exemption: /.j t(iat,. '( + \'1\CH'I\8-L~6t-l fAm<d (_U, (8<.0\Mif-'1\<JY\. & 4 Owner: (property owner) Mailing Address: Ph: A1tPh; KEVIN l.oN<"<> 5ot c~ 2'?,5 'S1~ U> 'iS. I<.. '52. '2;70-50(, 5 i3o'1-'Je.Z/5 5 Contractor: Mailing Address: Ph: A1t Ph: KEVIN L<l~c\C. "'~ 6 Architect I Engineer: l:£V II-\ \..-o Ni.<> Mailing Address: Ph: Alt Ph: 7 Sq. Ft. of Building: Sq. Ft. or Acres of Lot: . Height: /'51 No. of Floors: '2'-1 I( $-2 . !3. I I 8 Use of Building: t>e~~ (2,Ar.2v-tG£2 9 Describe Work: 10 Class of Work: ~!~New 01'\lU\0e o Alteration o Addition 11 Garage: !ILPetached Septic: o Attached oiSDS o Community 12 Driveway Permit: Owners valuation of Work: $ IS, ooo. DC NOTICE Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Pennit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by tlle Building Department. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local Jaw regulating the work and the Garfield County Building Code, JSDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Pennit does not prevent the Building Official from: (l) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regula.tion(s) or any other applicable Jaw. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or disCrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local Jaws and CoUnty Regulations rest with me and my authorized agents, including without limitation my archltect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: / ' '-1·23· 0'6 OWNERS SIGNATURE '-...W.TE v 0 STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Mise Fees: 13 ~24 /'74. Z/ 237. z:r- ISDSFee: Total Fees: Fees Paid: Balance Due: BP No & Issue Date: ISDS No & Issued Date: 'J?f.4fn /51{ J--1 GL-31-J--S 1 CC!tA -1PI410! - Setbacks: I OCC Group: ConstType: Zoning: .....-....r-/"\ ';..L.. ~c.. B~ JJ:J, (NN ;:]' .,., ~-2..-~ ' ~-2--~ APPROVAL DATE APPR OVAL DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all me and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. Bapplicationdecember2007 FEE ESTIMATE FOR SIF STICK BUILT HOMES (ALL FEES AREr!J?MATE~t!NTIL FINAL.PLANS ARE REVIEWED) Applicant: cfdV--4 ~ JobAddress: ,.0 { <;,¢J}5 5'.i£~ Subd-Lot/block: __ ""Gl._.'f_qg,......__.,b""''"f{..;..· ---------· ------- FINISHED LWING SPACE: -----......:•::_f X 74.68= ------- UNFINISHED BASEMENT: ----....:•::_f X41.00= ------- CRAWLSPACE:. sf X 9.00= --------~ GARAGE: _..::;;J..;....l[J.....,;.X_· ..;;;..:S_A.;._---_/..;_Co_<t _ __:;;_•f X 18.00= /~ ? ;l..f UNCOVERED PATIO/DECK: sf X 12.00= ----~ ------- COVERED PATIO/DECK: sf X24.00= -~----------~--- MISC: --------~------ krrS0....:·--------------- TOTAL VALUATION: THIS SECTION WILL BE DETERMEND BY GARFIELD COUNTY BUILDING & PLANNING PLAN REVIEW FEE: PERMIT FEE: TOTAL: PERMIT: SEPTIC= PERCi GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to rz the property lines from each comer of the proposed structure( s) prepared by a licensed surveyor tl-~ ·and has the surveyors signature and rofessional stamp on the drawing? Properties with slopes of 30% or greater must be s own on the site p an. Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision fmal plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a buildin envelo e of a Jot shown on a recorded subdivision plat shall include a copy of the bU! ding envelope as it is shown on the fmal plat with the proposed structure located within the e)lvelope_, Yes [/ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer Jot. Special setbacks do apply. / Yes. ____ _ 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes ;/ 4. Does the site plan indicate the location and direction of the County or private road accessing the property? / Yes t/ ·--'---- 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes / @o the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordans:~with the IRC or per stamped engineered design? Yes. _ __,tL__'----- 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances rgetuired between wood and earth? Yes V No ____ _ 8. Do the plans indic7ate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes No ____ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? / Yes _____ _ 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction'l Yes'--~-1-~~'---- 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or jPists or trusses? Yes __ __,i/~--- 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes _______ _ 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roo:t:iV(Building height measurement usually not to exceed 25 feet) Yes __ c_/ __ _ 1/. Does the plan include any stove or zero clearance fireplace planned for installation including make / . and model and Colorado Phase II certifications or phase II EPA certification? Yes No. ______ __ 3 ./Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? .1//1- Yes No______________ /v 16. Does the plan include a window schedule or other verification that egress/rescue windows from ~::ping p~dlor basements comply with the requirements of the IRC? 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes / 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No ____________ __ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes. ______ _ 20. Do you understand that if you are building on a parcel ofland created by the exemption process or the subdivisiqh process, are building plans in compliance with all plat notes and/or covenants? Yes v' ------- 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation 9r substantial modification of the plans. Yes 1L 22. Will this be the onl~idential structure on the parcel? Yes V No Ifno-Explain: ______ _ 23. Have two (2) COgJPlete sets of construction drawings been submitted with the application? . Yes __ C!_V __ _ 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes 'f'J (f>r 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? / Yes v ----- 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? / Yes ______ ~~~------ 27. Does the plan accurately indicate what you intend to construct and what will receive a fmal inspection by the GarfieLounty Building Department? Yes I 28. Do you understand that approval for design and/or construction changes are required prior to the application g:hhese changes? Yes __ __,vL--- 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impac " or "Septic System" fees required, at the time you pick up your building permit? Yes ___ -v--- 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003/ Yes V No ______ __ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inrction fee? Yes \ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on7final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ___ _y_ __ _ 33. Are you aware ~hat he Permit Application must be signed by the Owner or a written authority being given for an ent and that the party responsible for the project must comply with the IRC? Yes ---"---- 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable insp~. Yes 1 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Sched~le N ber for the lot you are applying for this permit on prior to submittal of a building permit plication? Your attention in this is appreciated. Yes ___ -"------ 36. Do you know that t e local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance/of a building permit that you will be required to obtain a grading permit? Yes V · 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of oCcupancy? Yes __ _,V:___ I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Signature of Owner Phone: "/1tJ -rH-..S"i' t,-(days); __________ (evenings) ProjectName: ~ ( Project Address: S?J{ {bl.ldl'ly fl.J j!.,?S: 5;/t U . r/6 t" 2 6 PLAN REVIEW CHECKLIST Applicant Lo!4Cy Date.--""~--=2.'-, <D___,I(s~---- Building -.dJ_Engineered Foundation A Driveway Permit ~eyed Site Plan ;J If. Septic Permit and Setbacks --c;;:de/Topography 30% ~ach Residential Plan Review List _4mum Application Questionnaire psubdivision Plat Notes __i,iJfire Department Review --~n Determination/Fees ~Line Plans/Stamps/Sticker L Attach Conditions _4cation Signed ~ __ PI~ann "Reviewer To Sign Application ~1/Schedule No. Ji/140# Snowload Letter-Manf. Hms. A.iJ.. Soils Report GENERAL NOTES: Planning/Zoning Aoperty Line Setbacks __/jjjpoft Stream Setbacks HFtood Plain ~ding Height ~Sign-off MRoad Impact Fees ~DRC Approval __ Grade/Topography 40% tLc..t/J.Ytanning Issues ~division Plat Notes Date: February 19, 2010 To: Kevin Long 501 CR235 Silt, CO 81652 Dear Permit Holder, Garfield County BUILDING & PLANNING DEPARTMENT Please refer to your building permit number 10969 , issued 6/4/2008 A routine review of our open building permits indicates that we have not received a request for an inspection on this permit since 11/132008. Please be advised that building permits expire, per Uniform Building Code, section 106.4.4 or lnemational Code Sections 105.5 "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the buliding or work authorized by such permit is suspended or abandoned at any time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do so, and the fee therefore shall be one half the amount required for a new permit for such work, provided no changes have been made or will be made in the oritinal plans and specifications for such work, and provided further that such suspension or abandonement has not exceeded one year. In order to renew action or a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work. If you have not responded within thirty (30) days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Clerk & recorders office that indicates that the work permitted per Colorado Revised Statues 30·28-205 & 210, was not inspected, is not approved and the building or area is illegal to occupy and is subject to legal abatement action or other option available by law. Thank you for your cooperation. Sincerely, Jim Wilson Building Inspector 108 Eighth Street, Suite 401 • Glenwood Springs, CO 81601 (970) 945-8212 • (970) 285-7972 • Fax: (970) 384-3470 No, ----------~10=9=6=9~---·Assessor's Parcel No. 2179-013-00-677 Date 6/4/2008 Phone # 970-876-5065 Phone # . 970-309-7225 Front ______ Rear _____ RH _____ LH _____ Zoning ____ _ Detached Garage Soils Test Footing h'---/..-:$"""--()"'7"'6-· 6h\ll~.,----_JJ.t:--,--·~-;;:-D--:-\l-, Foundation 0 -~ -zs~-o 2 0?! Grout ,; Underground PI u m bing -".v:;;T;0."'"'4'------ Roug h PI u mbi ng -:::-=---";0~~"-------­ Framing 11-t~-og-?"??: Insulation--------------- Roofing-------------- Drywall-------------- Gas Piping __________ _ INSPECTIONS NOTES Weatherproofing--------------- Mechanical _____ --=.----=---=------:---- Electrical Rough (State) /0·-Z'l:::.-oO' Electrlgal Final (State) 3-I-I 0 0::., Final3 J,.0-('D /Checklis~ ?9?PJe~ .IJti{ Certificate Occu pa~cy _# _..,_..,Q~':::j::C,__,....Z""-"'") ____ _ Date · • 2.'f, 0 Septic System # ____________ _ Date -------------,--Final ___________ _ Other _______________ _ (continue on back) UIL GARFiELD COUNTY, COLORADO INSPECTION Will!. NOT BE MADE UNLESS THOS CARD iS POSTED ON TNE JOB Date Issued _to~+'' o""'-'e"-------Permit No. Jn~t!_9 AGREEMENT MIT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location1 erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. Use ~ttuhed~'------------- Address or Legal Description 5{)1_~__1,_::3"'0-"""----S-v"'-j _.H:_._ ______________ _ Owner -~V'i 0 koo--!1\ Contractor _(}_WJ')f.C _____ _ Building Permit Type l2,e_<;;\_~a.j:o __________________________ _ This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway lr/6-NJ A)n1 urtt ol: Foundation I Grouting (/-'2--s:-:_ D'b p::u_ Insulation Underground Plumbing Drywall Ill& Rough Plumbing Electric Fin?// ;;g lns#p ~~ ;/J; (Prior to Final) Rough Mechanical Septic Final !V/!J Gas Piping FINAL 2/; j;o #/# IJm Electric Rough (by State lnsp~¥~ ~ {You Must Call For Final Inspection) /0 -).'1-ol' ::-Jj/~/7' 7 (Prior to Framing) Notes Framing //c!]<o!)~ (to include Roof in place & Windows & Doors installed & Flrestopping in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970-384-5003 Office 970-945-8212 108 8th Street, S"lte 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD (DO NOT LAMINATE) COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at So I Cl(, Z3"s- Permit No. /09'~ 9 I have this day inspected this structure and these premises and found the following corrections needed: &!£££) /Z/7 or ,?(/Vc#a;€ ~NQ c:YP BoL/s· crG;/J7///~;l £c::'A77c:s Eli?£ s?7Jr Cd?;t:K c)~ h4m /h?cs dt/ yo£ /%!17/Cs· /{lfc:H:(Iv<i/ t'U/A/CS /E /A/S?J/.A!/0/il ~II for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date /(.)-2._ 7 20 08 -~-- Building Inspector _ _.::C,./~~7• ~/ ~-· 66:..,,.,""-;-""'~=<.=J..t.)--'-{,""-'/c'-'/"".""'~""~""."""""''--=""----'""'-- Phone (970) 945-8212 . .- COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 5o I C I< ,';).. 3 S""" Permit No. lo96 '1 I have this day inspected this structure and these premises and found the following corrections needed: pfcau for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 1/-/,J-cl;? 20=---- ~~?_ .. ~ ,...--;?) Building Inspector --"~~=-=-"'""-'--4#""-'~~=-=-=-"--'"'--------- Phone (970) 945-8212 Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer pro~Search I As_s_essor Subset Q\i~n' I A:ts~_s_or Sales Search Clexk & RecordSlr Rec!!_pJion Search ParcSl,lDetail I Value_Detail I Sll1es Det<!il I Re:rid_~!ltial/CommerciallmprovemenLDetail Land DeJ<!il I PhotQgraphs I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 020 II R008231 II 217901300677 II 46.145 I Owner Name and Mailing Address \LONG, KEVIN J & GINA M REECE- \501 COUNTY ROAD 235 \SILT, CO 81652 Assessor's Parcel Description (Not to be used as a legal description) \SECT,TWN,RNG:1-6-92 DESC: A TR IN \NWSW AKA LOT 4 KELLY AND MICHAEL IL YON FAMILY, LLC EXEMPTION \PRE:R200385 BK:0439 PG:0055 BK:l713 \PG:516 RECPT:679450 BK:1536 PG:619 \RECPT:640443 BK:1514 PG:474 \RECPT:635690 BK:1325 PG:846 \RECPT:596697 BK:1325 PG:845 \RECPT:596696 BK:1325 PG:843 \RECPT:596695 BK:1324 PG:955 \RECPT:596537 BK:1324 PG:953 \RECPT:596536 BK:1313 PG:92 \RECPT:593913 BK:1313 PG:90 \RECPT:593912 BK:1313 PG:85 \RECPT:593911 BK:1242 PG:923 http://www.garcoact.com/ assessor/parcel.asp ?ParcelN umber=21790 13 00677 I I I I I I I I I I I I I I I I I I 6/3/2008 Parcel Detail Page 2 of 4 /RECPT:578724 BK:1242 PG:912 IRECPT:578722 BK:0980 PG:0208 Location I Physical Address: 11501 DAVIS POINT RD SILT I I Subdivision: I I Land Acres: 113.024 I I Land Sq Ft: llo I Section II Towns hi I! II Range I 1 II 6 II 92 I 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 129,oooll 10,2701 I Improvements: II 157,16oll 12,5101 I Total: II 286,16oll 22,7801 Additional Value_.Detail Most Recent Sale Sale Date: 118/29/2003 Sale Price: 11224,000 Basic Building Characteristics Number of Residential 1 Buildings: Number of Commllnd 0 Buildings: I Residential Building Occurrence 1 Characteristics I I 1 STORY: lj2,052 I I TOTAL HEATED AREA: 112,052 I I ABSTRACT CODE·IISINGLE F AM.RES- • IMPROVEMTS I II http://www. garcoact.com/ assessor/parcel.asp ?Parce!Number=21 79013 00677 6/3/2008 Parcel Detail Page 3 of4 I ARCHITECTURAL STYLE: //MANUFACTURED I I EXTERIOR WALL: 1/MASONITE I I ROOF COVER: //COMP SHNGL I I ROOF STRUCTURE: 1/GABLE I I INTERIOR WALL: 1/DRYWALL I I FLOOR: //SHT VINYL I I FLOOR: //CARPET I I HEATING FUEL: 1/GAS I I HEATING TYPE: 1/FORCED AIR I I STORIES: //STORIES 1.0 I I BATHS: 13 ROOMS: Is UNITS: /1 BEDROOMS: /4 YEAR BUILT: //1997 I Tax Information I Tax Year II Transaction Type II Amount I I 2007 II Tax Payment: Second Half II ($525.60)/ I 2007 II Tax Payment: First Half II ($525.60)1 I 2007 II Tax Amount II $1,051.201 I 2006 II Tax Payment: Second Half II ($431.1421 I 2006 II Tax Payment: First Half II ($431.14)1 I 2006 II Tax Amount II $862.281 I 2005 II Tax Payment: Second Half II ($431.12)1 I 2005 II Tax Payment: First Half II ($431.12)1 I 2005 II Tax Amount II $862.241 I 2004 II Tax Payment: Second Half II ($513.17)/ I 2004 II Tax Payment: First Half II ($513.17)1 I 2004 II Tax Amount II $1,026.341 I 2003 II Tax Payment: Second Half II ($569.84)/ I 2003 II Tax Payment: First Half II ($569.84)/ I 2003 II Tax Amount II $1,139.681 I 2002 II Tax Payment: Second Half II ($552.32)/ I 2002 II Tax Payment: First Half II ($552.32)/ I 2002 II Tax Amount II $1,104.64/ http://www. garcoact. corn/ assessor/parcel.asp ?ParcelN umber=21 790 13 00677 6/3/2008 Parcel Detail -~------·------- ToJLPfl'.age As~e!l.S_orD.atalla.Se SearcltOptions I I.rea.~w:er..Da1flbase Search Option~ Clerk & Recorder Di!1ab..illle..Se_arch Qptio_ns Page 4 of4 The Garfield County Assessor and Treasw:er's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by !lo...o_d_I.lJills Software. http://www .ga.rcoact. comlassessor/pa.rcel.asp ?Pa.rcelN umber=21 790 13 00677 6/3/2008