HomeMy WebLinkAboutApplication - PermitI
Garfield County
Building & Planning Department
108 8th Street, Suite #401 Glenwood Springs, Co . 81601
Office:970·945·8212 Fax: 970·384-3470
Inspection Line : 970·384·5003
Building Permit No.
Parcel No: 239 5-01 4-00-1 06
Locality:
Job Address : 183 Coryell Road , (183 cr 167), GWS --------
Use of Building: ·demo& rep lace w/new s/f w/open & cov pat ios & attached garage
--------~----------~----~--------~~----
Owner: Tuttle , Jeff & Cathy
Contractor: Owner
Fees: Plan Check: $ 1,210.14 Septic:
Bldg Pe rmit: $ 1,861.75 Other Fees :
Total Fees: $ 3,071.89
Clerk : ~\)( Date: -~\-08'"' I
2
3
4
5
6
7
8
9
10
II Garage:
12 Dri veway Permit:
GARFIELD COUNTY BUILDI NG PERMIT APPLICATION
108 81h Stree t, Suite401, Glenwood Spri ngs, Co 8 160 1
Phone: 970-945-8212 I Fax : 970-384-3470 I I nspecti on Line: 970-384-5003
www.garfi e ld-coun tv.com
o A lterat io n o Addition
Attached o Detached
Authority. Thi s appli cation for a Building Permit mu st be signed by the Own er of th e propeny, described above, or an authorized agent. If the signature be low is not that of the Ow ner, a separate
lener o f authority, signed by the Owner, mu st be pro vided wi th this App li cation.
Legal Acc~s. A Building Permi t cann ot be issued with out proof of le gal and adequate access to the propeny for purpos es of in spection s by the Bui ldi ng Department.
Other Permits. Multiple separate permits may be required : (I) State El ectri cal Permit, (2) County JSDS Permi~ (3) anoth er permit required for use on the propeny id entified ab ove , e.g. State or
Count y Hi ghway/ Road Access or a State Wastewater Di scharge Permit.
Void Permit. A Bu ilding Permi t becomes null an d void if the work authorized is not commenced within 180 days of the date of iss uan ce and if work is suspe nded or abandoned for a period of 180
days after commenceme nt.
CERTIFI CATION
I hereb y certify that I have read thi s Application and th at th e information contained above is true and correct. I understand th at the Building Department accepts th e App lication, along with the plans
and specifi cati ons and other data submitted by me or on my behalf (s ubmi ttals), based upon my certi fication as to acc uracy.
Ass uming completeness of the subminal s and appro,•al of this Applicatio n, a Building Permi t will be iss ued gran ti ng permi ss ion to me, as Owner, to construct the stru cture(s) and facilities detai led on
the submittals revi ewed by the Bui ld ing Department.
In cons id erati on of the issuance of the Building Permit , I agree th at I and my agents will comply with provis ions of any fed eral , state or loc al law regulating the work and the Garfie ld Co unty Bu il di ng
Cod e, ISDS regulati ons and applicable land use regu lations (County Regulation(s)). I acknow led ge th at the Buildi ng Pe rmi t may be suspended or revoked, upon noti ce from the County , if the location,
construction or use of the stru ctu re(s ) and facilit y(ies), descri becj abo ve , are not in compliance with Count y Regulation(s) or any other appli cable law.
I hereby grant permi ss ion to the Bui ldin g Department to enter the propeny, described abo ve, to inspect the work. I fun her acknowledge th at the iss uance of the Bu ilding Permit does not preve nt the
Bui ldi ng Official from : (I) requiring the correcti on of errors in the submittals , if any, di sco vered after issuance; or (2) stoppin g constru cti on or use of the stru cture(s) or facili ty (ies ) if such is in viola ti on
of County Regulati on(s ) or any oth er applicable Jaw.
Rev iew of thi s Appli cati on, in clud ing submi tta ls, and in spections of the work by the Building Department do not con stitute an acceptan ce of responsibility or liabilit y by the County of errors, omissio ns
or discrepancies. As the Owner, I acknow ledge that responsibi lit y for compliance with federa l, state and local laws and Count y Regulations rest with me and my authorized agents, includi ng with out
limit ati on my architect desi gner, engineer and/ or builder.
I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDER STAND THE NOTICE & CERTIFICATION ABOVE:
STAFF USE ONLY
Special Conditions:
Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Mise Fees:
25414:3 . [!:_ 1,Z io .J4 ~
Balance Due: ISDS No & Issued Date:
OCC Group: Const Type:
BLDGD PT:
/}~~-
APPROVAL DATE
The following items are required by Garfield County for a final Inspection:
1) A final Electrical Inspection from the Colorado State Electrical Inspector.
2) Permanent address assigned by Garfield County Building Department and posted at the
structure and where readily visible from access road.
3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows
installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent
kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all
necessary plumbing.
4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running
water, non-absorbent floors, walls finished, and privacy door.
5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks
over 30" high must be constructed to all me and IRC requirements including guardrails.
6) Outside grading completed so that water slopes away from the building;
7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of
extenuating circumstances., i.e. weather. Under such circumstances A Certificate of
Occupancy may be issued conditionally.
8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway
installation, where applicable; as well as any final sign off by the Fire District, and/or State
Agencies where applicable.
A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE
ABOVE ITEMS HAVE BEEN COMPLETED.
A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED.
OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED.
OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN
ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES
UNTIL ABOVE CONDITIONS ARE MET.
I understand and agree to abide by the above conditions for occupancy, use and the issuance of a
C.O. for the building identified in the Building Permit.
Bapplicationdecembe 2007
0 -'Co
DATE
VALUATION FEE DETERMINATION
Applicant
Address
Date
-'TC::u7'tt'=Je'-'R"'e"'s:;:id:;:en:.:;c:.:e':-:=-:-:=-==---Subdivision
183 Coryell Road, (CR-167) GWS Lot/Block
-:6,:;;/2:'.:7:7./20:0;!0::;:8====..:.::::..L=-"---Contractor
Finished (Livable Area):
Main
Upper
Lower
Other
Total
Basement:
Unfinished
Square Feet
Valuation
Conversion of Unfinished to Finished
Total
Garage:
Valuation
Crawl Space
Valuation
Valuation
1624 sf
sf
1440 sf
sf X $74.68
3064 sf
sf X $41.00
sf X $33.68
787 sf X $18.00
sf X $9.00
N/A
N/A
Owner
228,819.52
0.00
14,166.00
0.00
Decks/ Patios/Porch
Covered
Open
329 sf X $24.00 C
296 sf X $12.00
I} g~f., .
;;!<SS.;>.. -
ll,448.00 Valuation
Type of Construction:
Occupancy:
Valuation
Total Valuation
Commercial
sf X
sf X
sf X
sf X
sf X
sf X
0.00
254,433.52
PLAN REVIEW CHECKLIST
Applicant T LA--ft / ~ Date 6/z 7 /rJ 8'
~ I
Building
/ Eng ineered Foundation
f-.1/ It Driveway Permit
/ Surveyed Site Plan
/ Septic Permit and Setbacks
/ Grade/Topography 30%
J Attach Residential Plan Review List
/ Minimum Application Questionnaire
V f Subdivision Plat Notes
tvj!r Fire Department Review
vf Valuation Determination/Fees
t/ Red Line Plans/Stamps/Sticker
IV/If Attach Conditions
/ Application Signed
/'Plan Reviewer To Sign Application
/ Parcel/Schedule No.
fJ /!' 40# Snowload Letter-Manf. Hms.
tl!/J Soils Report
GENERAL NOTES:
Planning/Zoning
/Property Line Setbacks
fv /II 30ft Stream Setbacks
fJ /11 Flood Plain
/ Building Height
~ Zoning Sign-off
!V(A Road Impact Fees
tJj/1 HOAIDRC Approval
/ Grade/Topography 40%
rJ 1/t Planning Issues
o/.A Subdivision Plat Notes
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
For
SINGLE FAMILY DWELLING CONSTRUCTION
Including
NEW CONSTRUCTION
ADDITIONS
ALTERATIONS
And
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite the
issuance of a permit it is important that complete information be provided. When reviewing a plan and
it's discovered that required information has not been provided by the applicant, this will result in the
delay of the permit issuance and in proceeding with building construction. The owner or contractor shall
be required to provide this information before the plan review can proceed. Other plans that are in line
for review may be given attention before the new information may be reviewed after it has been
provided to the Building Department.
TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE
SUBMITTED FOR ALL APPLICATIONS.
Please review this document to determine if you have enough information to design your project
and provide adequate information to facilitate a plan review. Also, please consider using a design
professional for assistance in your design and a construction professional for construction of your
project. Any project with more than ten (10) occupants requires the plans to be sealed by a
Colorado Registered Design Professional.
To provide for a more understandable plan in order to determine compliance with the building, plumbing
and mechanical codes, applicants are requested to review the following checklist prior to and during
design. Applicants are required to indicate appropriately and to submit the completed checklist at
time of application for a permit.
Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn
to scale.
I
Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks,
balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and
original grade. A section showing in detail, from the bottom of the footing to the top of the roof,
including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation,
sheeting, house-rap, (which is required), siding or any approved building material. Engineered
foundations may be required.
A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be
designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed,
wind exposure B or C, and a 36 inch frost depth.
All sheets to be identified by number and indexed. All of the above requirements must be met or your
plans will be returned.
All plans submitted must be incompliance with the 2003 IRC.
1. Is a site plan included that identifies the location of the proposed structure or addition and distances to
the property lines from each comer of the proposed structure( s) prepared by a licensed surveyor
and has the surveyors signature and professional stamp on the drawing? Properties with slopes of
30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the
placement of any portion of a structure within 50 ft. of a property line and not within a previously
surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor
and have the surveyor's signature and professional stamp on the drawing. Any structure to be
built within a building envelope of a lot shown on a recorded subdivision plat shall include a
copy of the building envelope as it is shown on the final plat with the proposed structure located
within the envelope.
Yes 'I--
2. Does the site plan also include any other buildings on the property, setback easements and utility
easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the
property you are applying for a building permit on is located on a comer lot. Special setbacks do
apply.
Yes ><...
3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal
System) and the distances to the property lines, wells (on subject property and adjacent
properties), streams or water courses?
Yes Goc ,,s-t,t\'\ S'\.s \-ev-
4. Does the site plan indicate the location and direction of the County or private road accessing the
property?
Yes f-
2
5. Are you aware that prior to submittal of a building permit application you are required to show proof
of a legal and adequate access to the site? This may include (but is not limited to) proof of your
right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept.
of Highway Permit, including a Notice to Proceed; a permit from the federal government or any
combination. You can contact the Road & Bridge Department at 625-8601. See phone book for
other agencies
Yes p<.
6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel
in accordance with the IRC or per stamped engineered design?
Yes f
7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the
clearances required between wood and earth?
Yes No ________ __
8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and
soffits?
Yes ;<.. No ____ _
9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of
40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind
loads?
Yes __ ,..,._ ___ _
10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof
construct~?
Yes ___________ _
11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafters or joists or trusses?
Yes >(
12. Does the building section drawing or other detail include the method of positive connection of all
columns and beams?
Yes __ ......._ ________ __
13. Does the elevation plan indicate the height of the building or proposed addition from the
undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top
of a flat ro;f? (Building height measurement usually not to exceed 25 feet)
Yes __________ _
14. Does the plan include any stove or zero clearance fireplace planned for installation including make
and model and Colorado Phase II certifications or phase II EPA certification?
Yes I( No ·
3
15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply
with the IRC?
Yes "-No ______ _
16. Does the plan include a window schedule or other verification that egress/rescue windows from
sleeping rooms and/or basements comply with the requirements of the IRC?
Yes X..
17. Does the plan include a window schedule or other verification that windows provide natural light and
ventilation for all habitable rooms?
Yes >L
18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing for these areas?
Yes ;>( No -------
19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on
the plan?
Yes 'I...
20. Do you understand that if you are building on a parcel of land created by the exemption process or the
subdivision process, are building plans in compliance with all plat notes and/or covenants?
Yes ~
21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to
obtain written permission from the association, if required by that association, prior to submitting
an application for a building permit? The building permit application will be accepted without
it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in
revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans
have been reviewed by the Building Department prior to any action by the HOA that requires either
revocation or substantial modification of the plans.
Yes /IJ ~
22. Will this be the only residential structure on the parcel?
Yes II(. No Ifno-Explain: ______ _
23. Have two (2) complete sets of construction drawings been submitted with the application?
Yes IL.
24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long?
Yes '---''-'-----
4
25 0 Have you designed or had this plan designed while considering building and other construction code
requirements?
Yes ~
260 Do your plans comply with all zoning rules and regulations in the County related to your properties
zone district?
Yes ><..
270 Does the plan accurately indicate what you intend to construct and what will receive a final inspection
by the Garfield County Building Department?
Yes x,
280 Do you understand that approval for design and/or construction changes are required prior to the
application of these changes?
Yes ;>L-
29 0 Do you understand that the Building Department will collect a "Plan Review" fee from you at the
time of application submittal and that you will be required to pay the "Permit Fee" as well as any
"Road Impact" or "Septic System" fees required, at the time you pick up your building permit?
Yes i'-
300 Are you aware that you must call in for an inspection by 3:30 the business day before the
requested inspection in order to receive it the following business day? Inspections will be
made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in
to 384-5003.
Yes .?'-No. _____ _
310 Are you aware that requesting inspections on work that is not ready or not accessible will result in a
$50o00 re-inspection fee?
Yes ----L--=-----
320 Are you aware that you are required to call for all inspections required under the IRC including
approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the
building?
Yes J(
330 Are you aware that the Permit Application must be signed by the Owner or a written authority being
given for an Agent and that the party responsible for the project must comply with the IRC?
Yes_---'-"'----
5
34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and
Plumber to perform installations and hookups, unless you as the homeowner are performing the
work? The license number of the person performing the work will be required at time of
applicable inspection.
Yes ~
35. Are you aware, that on the front of the Building Permit Application you will need to fill in the
Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a
building permit application? Your attention in this is appreciated.
Yes --~~----------
36. Do you know that the local fire district may require you to submit plans for their review of fire safety
issues?
Yes (please check with the building department about this requirement)
37. Do you understand that if you are planning on doing any excavating or grading to the property prior
to issuance of a building permit that you will be required to obtain a grading permit?
Yes -b
38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees
have to be paid and the connections inspected by the service provider prior to the issuance of a
Certificate of Occupanc)\? \\
Yes '¥Hm;\\ed, W "C..
I hereby acknowledge that I have read, understand and answered these questions to the best of
my ability.
C:LT~
Signature ofO~er Date
-:1'-e. ~
:.n-soz..iD
Phone: 9LJS"-7'JJ~ (days); 1Y'S-7/zH (evenings)
Project Name: J' e ~ c;: c£ • • 0\...-\\\-e... \e..-; J ....... e.(
Project Address: ) ~ 3 C.\-t, -eJ \ LJ " ~ \8 ~ Co ~'4 e.\\ ~J
(;\~J ~('~xlj\ <t(bo I
6
Notes:
If any required information is missing delays in issuing the permit are to be expected. Work may not
proceed without the issuance of a permit. If it is determined by the Building Official that additional
information is necessary to review the application and plans to determine minimum compliance with the
adopted codes, the application may be placed behind more recent applications for building permits in the
review process and not reviewed until required information has been provided and the application rotates
again to first position for review, delay in issuance of the permit or delay in proceeding with
construction.
BpminreqDec2007
7
GARFIELD COUNTY
BUILDING REQUIREMENTS
Codes: 2003 IRC, IBC, IFGC, JMC, IPC,
Setbacks: Check subdivisions and zone district for setback requirements.
Snow load (measured at the roof): 40PSF up to 7000ft. elevation.
50PSF 7001 to 8000ft.
7 5PSF 800 I to 9000ft.
lOOP SF 900 I to 1 OOOOft.
Seismic design category: B
Weathering probability for concrete: Severe
Termite infestation probability: None to slight
Wind speed: 90mph
Decay probability: None to slight
Wind Exposure: B or C (see section R301.2.1.4)
Frost Depth: 36in. to 8000ft. elevation. 42in. 800 I and above.
Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft.
elevation.
Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by
Building Official.
Ice shield under-layment required.
Mean Annual temp.: Variable
Insulation: Maximum glazing U factor: 0.50
Minimum R-Values:
• Ceilings/roofs R values are: R-30 stick built
structures. R-38 log construction and steel
rafter construction.
• Walls R values are R-19 wood frame; R-19
cavity R-3 sheathing steel studs.
• Floors R-values are R-19.
• Basement wall R-values are R-10 bel'ow
grade, R -19 above grade.
• Slab perimeter R-value and depth is R-
10/36in.
• Crawl space wall R-values are R-10 below
grade and R-19 above grade
If floors over crawl spaces are not insulated, the crawl space walls must be
insulated. Basement wall must be insulated to frost depth. Common walls
garage to house must have R-19 insulation. Common ceiling/floor garage
to house must have R-19. Take precautions to protect plumbing in these
areas.
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at 0 If> 3 ~4 M
PermitNo.-LLC~+--------------------------------
I have this day inspected this structure and these
premises and found the following corrections needed:
d{;,J;,-4 ~??A,&:~z;::=-?&. & .. (/ z;
~I for Re-lnsoection
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date 2-;]'-o 2:$"
20 -:::=;--==--
Building Inspector ~~
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at /'g 3 Co If ~ L C ./C P'
7
Permit No. //0 t'? 9
I have this day inspected this structure and these
premises and found the following corrections needed:
/ /ti4:£P 77ft~s.:s JZ'b/JS a ;r/ S;7/c,
-:2 E2.oo~ .;::r;?;.s! cq/ A/ 7CJ/L/?:T-
"3 £c;;...£Es.s /ii!?GRz:= 4-<t-~'1 !?1A Y.
<f .11£1£1? .sd~c/ od /JIA-57&/f !?ftt. Oft/..55£.5 •
.::> 5A"~oc o.ldr-<s 4;:;. ~/~}! . ~ J/.&£: ~/S/ c&t.c:..r c: =--s-::azu-~~)
7£15/ 2??-ocK 4"L' CAIIJ77t.L;v:o( .
C/l;z:c/f cAl ((f',s;pg;_ i?ouJd /UtNGU5
.!?1A.>< t~Aq' !AI 1?/5£./CS ~~'INA gt;AJ
d/A! AJ!z&AJ E/;<K 5i£/9zQJ;7/;/tl &46.e:
. ~ b-.,<J£,;(Jc;:;-£..,...;-/01(£ CA.tlt/<,
~r Re-lnspection AA!cl/of( JJoc:..75-/?AS4nozf/,"
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384·5003.
Date 9'-7 20 oe-
suilding Inspector s;:z-~ ~
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at t?(g-3 C!-1< 16 7
Permit No. -'-'JZ'-'(;..,:&'~9-------------
I have this day inspected this structure and these
premises and found the following corrections needed:
¥J~~M ~~~f~
s~~~a~pz
~Call for Re-lnsoection
50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date q-/2 -CJ If 20
Building Inspector ~;;:·~ ;;;.;r--;=;;;_--
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone (970) 945-8212
Job located at / 8 3 t:_(::;7 ~.Y£i {_ &'12
Permit No. //Ct!? 9
I have this day inspected this structure and these
premises and found the following corrections needed:
}5_,t:::-_s-4/~ £ . ~ /'?/ r;r--
//(/ Afl/ c A C'C/Z:.S :s
ZJ/~X'J/"'.?'IY~ kL. <>'b-.... V K
0 Call for Re-lnspection
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date 9'-/s--20 0?
Building !~spector ~ ~~
Phone (970) 945-8212
COUNTY OF GARFIELD -BUILDING DEPARTMENT
CORRECTION NOTICE
108 8th St., Suite 401 Glenwood Springs, Colorado
Phone(970)945~212
Job located at cJ IS 3 /!:):{ lb 7
I have this day inspected this structure and these
premises and found the following corrections needed:
Kcall for Re-lnspection
0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection
You are hereby notified that the above correction must be inspected
before covering.
When correction(s) have been made, call for inspection at 970-384-5003.
Date -lfll--/cJ.. ~kJ -0 a= 20 --=~;;=-
Buildi;glnspector ~~:?'J
Phone (970) 945-8212
No. 11009 Assessor's Parcel No. 2395-014-00-1 06
Date 7/1/2008
BUILDING PERMIT CARD
Job Address 183 Coryell Road. (183 CR 167). Sfii: f2 ... 2llc#dcf ~?"S
Owner Tuttle. Jeff & Cathy Address 183 Coryell rd. silt Phone # 379-5026
Contractor Tuttle, Jeff & Cathy Address same ' Phone # 945-7924
Setbacks: Front Rear RH LH Zoning ____ _
demo & s/f w/open & cov patios & attached garage INSPECTIONS
Soils Test -==------...,--------o
Footing G-A/.?f-llot6f +(Mo//11/p r Z:~ o8y{'ccj.
Foundation 7-9~ /7 72.._-cW~
Grout __________ ~~~---~-
Underground Plumbing ~
Rough Plumbin
Framing ___ ~:_.::.~,L_=c~;L__~,c:_~;:::.....
Insulation _..£.::..JC..<"""'-~~:.!:.L.~~----
Roofing ---,-------------
Drywall to-G-o t''?m---
Gas Piping <=t-.q=-c>t~
Weatherproofing ___________ _
Mechanicai _____ ~~-------
Eiectri cal Rough (State) ~9:::"--'::s:==----""".8=-------
Eiectrical Final (State) 1/ ... 19-o'i{ c ~inal /,). ~11~ /Checklist C~!llRieted? 17
Certificate Occupancy#~l.-fj ~
Date l~<:i~ 2. ·2Z·'--"'C7
Septic System # __,~<LX-'--\;1<.!~"'-'\;'-"W~\~~>--------
Date -------------Final, ____________ _
Other __________________ _
NOTES
(continue on back)
BUILDING PERMIT
GARFIELD COUNTY, COLORADO
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
Date lssued __ ")-'--_\):.._\-()___c"K=-----Permit No. _ __,\~\\)-'-~-~.!__ ___ _
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations
related to the zoning, location; construction and erection of the proposed structured for which this permit is
granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location,
erection and construction of the above described structure, the permit may then be revoked by notice from the
County Building department and IMMEDIATELY BECOME NULLANDVOID.
use htW\o t "if. w(a!tf\ ~ tU\1 pGifo:s l-Q~'rllt'llt'Cl ~o.rnse ·
AddressorLegaiDescription \~ (?t\t'(d ttl( \~CT"\~"\-) Gw~
Owne,:-nr\\te .len f-C()\h'f Contractor_()\J--"'UJ""-'-1\,_,e,_,_r _______ _
Building Permi!Type te~\dtnlfalr ~W\0
This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection
INSPECTION RECORD
Footing ~ .. ,. Driveway
'if;{ifk·-1-/lo<'6/C 7-Z--0 if )"<·"-1..;. 4~ I i!]fi.O'-<N 1/·Js-.o?
Foundation I Grouting /-9·01?~ Insulation
7-17-<:JR~ 9-.:< ::< --<! ~-~
Underground Plumbing
7-Z_¢'.-&8 oK r;:tit! Drywall
I0-6·&~
Rough Plumbing 9'-5-0?~ Electric Fina~tat• 17/:~r)
o{J--!I!'/, ~
(Prior to Final)
Rough Mechanical cfjit"-Septic Final
...J& ',/._'
GasPiping q--=><>'6~ FINAL (/
f:Z-1!-a! ~fr?~
Electric Rough (by State Inspector) {You Must Call For Final Inspection) Of-/l;-1-7 f/stoB Notes (Prior to Framing)
Framing '1-/5--c?.% /30'
(to Include Roof In place & Windows & Doors instal1ed & Flrestopping In place)
THIS PERMIT IS NOTTRANSFERABLE
For Inspection Call970-384-5003 Office 970-945-8212
108 8th Street, Suite 401 Glenwood Springs, Colorado 81601
APPROVED 1--"\-('U'
Date ________ ~_Jl)~-~~~~---------BY-L~~LJ~~~--~~~~--------
DO NOT DESTROY THIS CARD:,_,.-.-""'\":
PROTECT PERMIT FROM WEATHER DAMAGE
(DO NOT LAMINATE)
Parcel Detail Page I of4
Garfield County Assessor/Treasurer
Parcel Detail Information
Assessor/Treas_u_rer Prol)er!y Search I A_sses.sJJLSubs_eLQuenr I Assessor Sales SearQh
Clerk & Recorder Re_c:eptio!l_Se<!Ich
Basic B_yilding Characteristics I Tax I_nfQ!:mation
P.ar9_el Detail I Value Det<~il I Sales Detail I Reside.ntialf~Q!111lJerg!!Umprovement Det<lil
Land Detail I Photogrnphs
I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I
I 011 II Rlll461 II 239501400106 II 60.843 I
Owner Name and Mailing Address
!TUTTLE, JEFF & CATHY
1226 HETLER LANE
!GLENWOOD SPGS, CO 81601-9322
Assessor's Parcel Description
(Not to be used as a legal description)
ISECT,TWN,RNG:l-7-89 DESC: TR IN
ILOTS 18 & 21 PRE:ROI1538 BK:0931
IPG:0665 BK:0563 PG:0578
IRECPT:745961 RECPT:745960
IRECPT:745077 RECPT:745076 BK:l717
IPG:931 RECPT:680416
Location
I
I
I
I
Physical Address: 183 167 COUNTY RD GLENWOOD SPRINGS I
Subdivision:
Land Acres: 1.95
Land Sq Ft: 0
Section II Township II Range I
I II 7 II 89 I
http://www. garcoact. com/assessor/parcel.asp ?ParceiN umber=23 9 50 1400 I 06 6/6/2008
Parcel Detail Page 2 of4
2008 Property Tax Valuation Information
II Actual Value II Assessed Value I
I Land: 3so,oooll 27,8601
I Im~rovements: 196,22oll 15,6201
I Total: 546,22oll 43,4801
Additional V aJJle_O~Jail
Most Recent Sale
Sale Date: 113/20/2008
Sale Price: 11700,000
Additional Sales Detail
Basic Building Characteristics
Number of Residential 1 Buildings:
N urn ber of Comm/lnd 0 Buildings:
Residential Building Occurrence 1 Characteristics
1 STORY WI BASEMENT: 11858
UNFINISHED BSMT: 11858
FINISHED BSMT: 11858
1 STORY: 11526
TOTAL HEATED AREA: 112,242
IISINGLE FAM.RES-
ABSTRACT CODE: )MPROVEMTS
ARCHITECTURAL STYLE: 111-STRY/BSM
I EXTERIOR WALL: IIBOARD/BATT
ROOF COVER: llcOMP SHNGL
ROOF STRUCTURE: IIGABLE
INTERIOR WALL: I lA VG pANEL
INTERIOR WALL: IIDRYWALL
FLOOR: IICARPET
FLOOR: llsHT VINYL
http://www. garcoact.cornl assessor/parcel. asp ?ParcelN umber=23 9 50 1400 I 06 6/6/2008
Parcel Detail Page 3 of 4
HEATING FUEL: IlGAS I
HEATING TYPE: IIHOTWATER I
STORIES: IISTORJES 1.0 I
BATHS: I 1.5
ROOMS: Is
UNITS: II
BEDROOMS: 13
YEAR BUlL T: 111960 I
Additional Re§idmtial/Commercial lmJlrQ_y~mentl2t;1illl
Tax Information
I Tax Year Transaction Type Amount I
I 2007 Tax Payment: Whole ($2,645.44)1
I 2007 Tax Amount $2,645.441
I 2006 Tax Payment: Whole ($2,381.52)1
2006 Tax Amount $2,381.521
2005 I Tax Payment: Whole ($2,391.84)1
2005 Tax Amount $2,391.841
2004 Tax Payment: Whole ($2,426.44)1
2004 Tax Amount $2,426.441
2003 Tax Payment: Second Half ($1,019.97)1
2003 Tax Payment: First Half ($1,019.97)1
2003 Tax Amount $2,039.941
2002 Tax Payment: Whole ($2,011.52)1
2002 Tax Amount $2,011.521
2001 I Tax Payment: Whole ($2,022.68)1
2001 II Tax Amount II $2,022.681
2000 Interest Payment II ($59.32)1
2000 Interest Charge $59.321
2000 Tax Payment: Whole ($1 ,977.46)1
2000 Tax Amount $1,977.461
1999 Tax Payment: Whole ($1,950.60)1
1999 Tax Amount $1,950.601
TOR. Q[_fJtg~
http://www. garcoact. corn/ assessor/parcel.asp ?Parce!N umber=23 9 501400 1 06 6/6/2008