Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co . 81601 Office :970·945·8212 Fax: 970-384-3470 Inspection Line: 970-384-5003 Building Permit No. lJl1b_l:l ___ _ Parcel No: 2127-251-00 -068 Locality: Antlers Orchard Dev AMD, tract 29 Job Address: 0133 Lafrenze Lane, Silt Use of Building: Personal storage Owner : Zarlengo, Anthony & Catherine Contractor : Jefferies Canst ------~----------------- Fees: Plan Check: $ 90.51 Septic: Bldg Permit: $ 139.25 Other Fees : Total Fees: $ 229.76 Clerk : ~ Date: -D=~O:Q~-I 2 3 4 5 6 7 8 9 GARFIELD COUNTY BUILDING PERM IT APPLICATION I 08 81h Street , Sui te 401. G le nwood Springs, Co 8160 1 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspect ion Line: 970-384-5003 www . garfield-cou nt y.com Sq . Ft. of Building: :3~ 11.(~-z.l( He igh t: Use of Building~!:OI)<X. Descri be Work: NA 10 C lass of Work: New o Alteration o Addition II Gara fftR o i SDS 12 Driveway Permit: Nf\ _ • '/'J.. I No. of Floors: Authority. This application for a Building Permit mu st be signed by the Owner of the propeny. described above. or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by th e Owner, mu st be provided with this Application. Lega l Access. A Building Permit cannot be iss ued without proof of legal and adequate access to the propeny for purposes of inspections by the Building Depanrnent. Other Permits. Mu ltip le separate permits may be required : (I ) State Electrical Permit , (2) Cou nty ISDS Permit, (3) another permit required for us e on the prope ny identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes nu ll and void if the work auth orized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Appli cation and that the information co ntained above is true and correct. 1 understand that th e Building Departmem accepts the Application, along with the plans and specifications and other data submitted by me or on my beha lf (s ubmittal s), based upon my certi fi cati on as to accur•cy. Assuming completeness of the submittals and approval of this Applicatio n, a Building Permit wi ll be issued granting permission to me, as Own er, to co nstru ct the structure(s) and fac ilities detailed on the submittals reviewed by the Building Depanment. In consideration of the issuance of th e Buil di ng Permit, I agree that I and my agents will comply with provision s of any federa l, state or loca l law regulating the work and th e Garfield County Build ing Code, ISDS regulatio ns and applicable lan d use regu lation s (County Regulation(s)). I acknowledge that the Buildin g Permit may be suspen ded or revoked , upon no tice from the County, if the location, construction or use of the structure(s ) and faci lity(ies), described above , are not in compli ance with Count y Re gulation(s) or any othe r applicable Jaw. I hereby grant permi ssion to the Building Depanment to enter the propeny, described above, to inspect the work . I funher acknowledge th at the iss uance of the Bui lding Permit does not prevent the Building Official from: (I ) requiri ng the correction of errors in the submittals , if any , di scovered after issuance; or (2) stopping construction or use of the struc ture(s) or facility(i es) if such is in violatio n of County Regulation(s) or any other app li cable law. Review of this Application , includin g submitta ls, and in spections of the work by th e Buildi ng Department do not consti tute an acceptance of respons ibility or liability by the County of errors, omis sions or disc repancies. As th e Owner, I a knowledge that re spon sibility for compliance with federal, state and loca l Jaws and County Regu lations rest with me and my authorized age nts, including without limitation mx architect designer, e ineer and/ or builder. I HEREB CKNOW LEDGE HAT I HAV E READ AND UNDERSTAND THE NOTICE& CERTI FICATION ABOVE: la -8({~ DATE STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: P ermit Fee: Manu h o me Fee: Mise Fees: 60'(~~ 9o.9-rs c;.~ .-"/ . --ISDS Fee: T otal Fees: cio ~~=J Bala nce Due: BP No & Is sue Date: ISDS N o ~ Issued Date: ---J 22f.l£ /3 9, z.L ~.\om f0 1 Setbacks: OCC Group: Const Type: Zoning: ~/ z5: 10 / i/!2-/1'-D /t.EPT', ~EPT' f?/v/c;y :A'/~e 8;~'cJ8-~--P- A PPROVAL--DATr-APPROVAL ' D..(TE The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical In spector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops an d fini s hed walls , ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-ab sorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails . Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be i ssued conditionally. 8) A final in spection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final s ign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. OWNE~~ DATE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date .:;Z,a,_,rl-"en"'g"'o'-------------Subdivision ===-=-----------Lot/Block .::8::.:12:..:1'-"/2:..:0:.::0.::.8 __________ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Garage/Shed Carport: Valuation Total Valuation Crawl Space Total Decks/ Patios Total Valuation Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation sq.ft sq.ft sq.ft sq.ft X $74.68 0 sq.ft sq.ft X $41.00 sq.ft X $33.68 336 sq.ft X $18.00 sq.ftX $12.00 Commercial sq.ft X $9.00 sq.ft X $24.00 sq.ft X $12.00 sf X sf X sf X sf X sf X sf X Antlers Orchard Lot29 Jeffries Construction 0.00 0.00 6,048.00 0.00 0.00 0.00 6,048.00 PLAN REVIEW CHECKLIST Applicant Z.A J?--letA-y o Date B/z;/qB Building 'i!_Engineered Foundation tJ( .A Driveway Permit / Surveyed Site Plan tf/J Septic Permit and Setbacks _Loradeffopography 30% ,/ Attach Residential Plan Review List 7 M.. A 1· . Q . . __ llllmum pp 1cat10n uestwnnatre /' Subdivision Plat Notes /fA Fire Department Review /Valuation Determination/Fees t/ Red Line Plans/Stamps/Sticker 7 Attach Conditions ~ Application Signed 7 Plan Reviewer To Sign Application /Parcel/Schedule No. \/ 40# Snowload Letter-Manf. Hms. !&..__ Soils Report GENERAL NOTES: Planning/Zoning / Property Line Setbacks l'j'A 30ft Stream Setbacks 7 Flood Plain __ Building Height / Zoning Sign-off if A Road Impact Fees !{A HOAIDRC Approval / __ Gradeffopography 40% ~Planning Issues V Subdivision Plat Notes GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 :MINIMUM APPLICATION REQUIRE:MENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and exp edite the issuance of a permit it is important that complete information be provided . When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for re view may be given attention b efo re the new information may be reviewed aft e r it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTEDFOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in ord er to determine compliance with the building, plmnbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps , hand rails and guard rails, windows and doors , including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar , anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed , wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor 's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes c 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply . Yes ,..- 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties ~ streams or water courses? Yes Nb-t 4. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes v 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes VA 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes AJ(j. ' 7 . Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes fV'Pr No ___ _ 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes Nf\-No ----- 9. Do the plans include design loads as required by Garfield County for roof snow loads , (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes NA= 10. Does the plan include a building section drawing indicating foundation , wall, floor, and roof construction? Yes t-1& 11 . Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes AJ& 12 . Does the building section drawing or other detail include .the method of positive connection of all columns and beams? Yes N'A 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes AI'A 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes ,A){\. No · 3 15 . Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes Nf\ No ______ _ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes }JP. 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms ? Yes Nf.t 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors ; glazing adjacent to an y surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes AlA No ------- 19 . Is the location of all natural and liquid petroleum gas furnaces , boilers and water heaters indicated on the plan? Yes A/A I 20 . Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes Mfl 21 . Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes AlA 22 . Will this be the only residential structure on the parcel? Yes f!A-No Ifno-Explain: _____ _ 23 . Have two (2) complete sets of construction drawings been submitted with the application? Yes NB 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes ltJ& I 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes tJA- 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? Yes .NP.t. 27. Does the plan accurately indicate what you intend to construct and what will receive a fmal inspection by the Garfield County Building Department? Yes tv¥\ 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes NA 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road ~ct" or "Septic System" fees required, at the time you pick up your building permit? Yes · 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-SO()J. Yes All+ No ------ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes /VA • 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes NA 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given fo t£Vgent and that the party responsible for the project must comply with the IRC? Yes ' 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups , unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes AlA 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a ~~~ding pe/rYAapplication? Your attention in this is appreciated. 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues ? Yes /l!A (please check with the building department about this requirement) 37 . Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes AlA. 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes Nfl I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. signa~~~O Date ~'{41tiaeP Phone :CQo -rct:fJ=?:J5 (days); __________ (evenings) ProjectName: Qj~ laQu/1? [1\{l~ 2~~c Stt>t ~~ Project Address: _____ \1/_l _____________________ _ 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building pei:mits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpmimeqDec2007 7 N 11084 o. ----------~~~-----Assessor's Parcel No. 2127-251-00-068 Date 812812008 BUILDING PERMIT CARD Job Address ----~0~1~3~3~L=a~F~re=n~z=e~L~a=n~e~·~S~il~t __ (sA2n~t~le~rs~O~rc=h~a~r~d~D~e~v~A~M~D~,~tr~a~c~t=2~9)~-------------------- 0wner Zarlengo, Anthony & Catherine Address 1147 N. 16th St, Silt Phone # 876-5998 Phone # 876-5276 Contractor _______ J_e_ff_e_ri_e_s_c_o_n_st_r_u_ct_io~n ________ Address 023 Lafrenz In, Silt Setbacks: Front ______ Rear ---------RH, ______ LH _____ Zoning ----- Personal storage Soils Test ----------------------- Footing-------------------- Foundation, ____________ _ Grout _______________________ _ Underground Plumbing ---------- Rough Plumbing ----------Framing ____________________ _ Insulation---------------- Roofing--------------- Drywall --------------- Gas Piping------------- INSPECTIONS NOTES Weatherproofing ______________ _ Mechanical ________________ _ Electrical Rough (State)---------- Eiectricjtl r;jJmL{State) rl-:; Final/7--~-«5 /Checkli t Cor;t;~_pJeted? ;7./Vj Certificate Occupancy# 'lit? .. Date t -'E::. I · Septic System # -~-f-I..L----J::...UXJJ..!LC::I,----­ Date ------------==-----Final ____________ _ Other ___________________ _ (continue on back) BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THIS CARD JS POSTED ON THE JOB Date Issued '5 · 2'5. CJe:> Permit No. ___,_1--'-'-1 o--=-?:1_.__~-- AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with In the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building departmentand IMMEDIATELY BECOME NULL AND VOID. use f?enonrL ~fW#- Address or Legal Description~\'~ La' lfble' lrl1 S11:\-. Owner lor\trt~ flnlb.OJ\'f \-Qn\-btri~ontractor< 'eB=rn<=> r~Y\sl-. Building PermitType Re'S,\dt't\te. This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway Foundation I Grouting Insulation Underground Plumbing Drywall Rough Plumbing Electric Final (by Slate Inspector) (Prior to Final) Rough Mechanical Septic Final Gas Piping FINAL /t.. -7-/-z;8' az...._ Electric Rough (by Slate Inspector) (You Must Call For Final Inspection) (Prior to Framing) Notes Framing (to Include Roof in place & Windows & Doors installed & Firestopping in place) THIS PERMIT IS NOTTRANSFERABLE For Inspection Call970-384·5003 Office 970·945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD Parcel Detail Page I of 4 Garfield County Assessor/Treasurer Parcel Detail Information All$J!Ssor/TreasuriTPro~r!)r_Search I Assessor Subset Q_llt;_l)' I Asse_s~m Sales Search Clerk& Recorder Reception Search BaskB_uilding Chara~teristiQS I Tax Information Parc~LDetail I Yalue Del<~il I Sal~S_Qetail I Res_idential/Commercial ImpJoYemmtP~1<!il Land Detail I Photog!1lJ>hs I Mill L~}l)' Revenues Detail I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 020 II R008140 II 212725100068 II 46.145 I Owner Name and Mailing Address jzARLENGO, ANTHONY A & CATHERINE A I1147NORTH 16 ST jSILT, CO 81652 Assessor's Parcel Description (Not to be used as a legal description) jSECT,TWN,RNG:25-5-92 DESC: AMENDED jTRACT 29, AMENDED FINAL PLAT TRS 29 I& 36 & PT OF TRS 28, 30 & 37 OF jANTLERS ORCHARD DEV. ALSO A TR OF jLAND CONT 21,701 SqFt (.SAC)+/-AS jDESC ON AMENDED FINAL PLAT OF THE jAMENDED TRACTS 29 & 37 OF ANTLERS jORCHARD DEVELOPMENT COMPANY PLAT NO Ji REC 646777 AND QCD 1564/733 , jPRE:R200402 PRE:R007935 SPEC ASMT: jSILT WATER PROJECT BK:942 PG:594 jBK:0417 PG:0514 BK:0416 PG:0377 jRECPT:742246 RECPT:742245 BK:1942 jPG:383 RECPT:726599 BK:1942 PG:382 jRECPT:726598 BK:1942 PG:381 http://www. garcoact.corn!assessor/parcel.asp ?Parce!N umber=212 7251 00068 I I I I I I 6/25/2008 Parcel Detail Page 2 of4 IRECPT:726597 BK:1596 PG:301 II IRECPT:654087 BK:1564 PG:733 IRECPT:647398 BK:1504 PG:231 IRECPT:633871 BK:1504 PG:214 IRECPT:633872 BK:1504 PG:212 IRECPT:633870 BK:1291 PG:578 IRECPT:589431 BK:1268 PG:875 IRECPT:584407 BK:1268 PG:872 IRECPT:584406 BK:0998 PG:0638 Location Physical Address: llsrL T I Subdivision: I Land Acres: 116.717 I Land Sq Ft: llo Section II Township II Range I 25 II 5 II 92 I 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: 165,0ooll 47,8501 I Improvements: II Oil 0 I Total: 165,oooll 47,8501 Mdi tional_Yg~J 1l~_Det~il Most Recent Sale Sale Date: 111130/2008 Sale Price: 11271,000 Additional Sale~ _D~tail Basic Building Characteristics Number of Residential 0 Buildings: Number of Commllnd lo Buildings: I http://www.garcoact.com/assessor/parcel.asp?ParcelNumber=2127251 00068 6/25/2008 Parcel Detail No Building Records Found Tax Information Tax Year II Transaction Tn:!e I Amount I 2007 I Tax Payment: Whole ($2,208.04)1 2007 Tax Payment: Whole ($258.00)1 2007 Tax Amount I $2,208.041 2007 Tax Amount II $258.001 2006 Tax Payment: Whole II ($321.00)1 2006 Tax Payment: Whole II ($1 ,948.92)1 2006 Tax Amount $321.001 2006 I Tax Amount $1,948.921 2005 Tax Payment: Whole ($321.00)1 2005 Tax Payment: Whole ($1 ,948. 78)1 2005 Tax Amount I $321.001 2005 Tax Amount II $1,948.781 2004 Tax Payment: Second Half II ($160.50)1 2004 I Tax Payment: Second Half II ($10.60)1 2004 Tax Payment: First Half II ($10.60)1 I 2004 Tax Payment: First Half II ($160.50)1 2004 Tax Amount I $321.001 2004 Tax Amount $21.201 2003 Tax Payment: Whole ($108.00)1 2003 Tax Payment: Whole ($23.56)1 2003 I Tax Amount $108.001 2003 II Tax Amount I $23.561 2002 II Tax Payment: Whole II ($23.28)1 2002 II Tax Amount II $23.281 2001 II Tax Payment: Whole II ($23.16)1 I 2001 II Tax Amount II $23.161 Mill LeYyRevenues Detail Top ofPag~ Ass~_&S_QrJ)atabase Search Qptiom I Treasurer_ Database Search OpJions Clerk &:_Re_corder Database Search0ptiQUil http://www. garcoact.corn/assessor/parcel.asp ?ParcelN umber=212 7251 00068 Page 3 of4 6/25/2008 PRIME BUILDING CONTRACT (Not to be used for Home Improvement) This form complies with professional standards in effect January !-December 31, 2006 THIS AGREEMENT IS BETWEEN: Jefferies Construction Inc. (Contractor's Name) B.E.S.T. Card 50083 (Contractor,s License Number) 023 Lafrenz Lane (Contractor's Address) Silt, Co. 81652 (City, State, Zip) OFFICE 970-876-5276 CELL 970-379-3986 (f elephone) REPROJECT: Anthony and Cathy Zarlengo (Owner's Name) 1147 16"' St (Owner's Home Address) Silt, Co. 81652 (City, State, Zip) SAME (Owner's Business Address) SAME (City, State, Zip) CONSTRUCTION LENDER: Name and address of construction fund bolder is: Wells Fargo Home Mortgage 931 Grand Ave. Glenwood Springs, Co. 8160 I Sean Martin 970-945-9413 (Name and Branch Address of Bank. Saving and Loan Assn .• Escrow Agent, Joint Control or Other) Work performed at TBD Lafrenz Lane Silt, Co. 81652 Lot 29: Amended Tract29 Antlers Orchard Silt, Co. 81652 (Street Address And Legal Description If Known) We hereby propose to furnish all materials and necessary equipment, and perform all labor necessary to complete the following work (Describe Labor, Material And Equipment To Be Furnished): All Sub-Contractors including Licensed Electrician, Licensed Plumber and Licensed Structural and Civil Engineers. All other Sub-Contractors not required to be licensed, but whom shall be fully insured, all materials to complete said work including, but not limited to: Road work, Leach Field, Propane Tank Installation, Well Pump. All work shall be done in a timely manner and shall be completed within the loan guidelioes. TIME FOR COMPLETION: The work to be performed by Contractor pursuant to this Agreement shall be substantially completed within one year of signed loan documents (365) days or approximately on .....:;llce3..:.1fc::Oc::9c../ ----;;;:=------- (Dote) PAYMENT: This is a cash transaction. Owner agrees to pay Contractor a total cash price of. Three hundred fifty one thousand nine hundred sixteen Dollars ($351,916.00) Down payment (if any) $0.00 with payments to be made as follows: Mouthy draws shall be done as work completed. Contractor shall draw $2,500.00 per month( for Supervision Fees) with balance due upon final Certificate of Occupancy. Il'ITERl:ST: Overdue payments will bear interest at the rate of I Y, % per month. Firm Name: Date: l~hs/o7 ' By: X Owner: X Date: x N./J. s-/u 7 r--- Owner: X Date: X /d6tscf} TERMS AND CONDITIONS: The tenns and conditions on the next page are expressly incorporated into this Agreement ©ABCAForms.com 2006 Consnlt a lawyer if you doubt the form's fitness for your purpose and use. /06 /06 Jul 18 08 11 :53a 970-254-4694 p.1 ......... -----~--------------------------, PHONE: ;)s-o -)::>,>:;> FAX: rz, · 3-P(· JY~ RE: lJ URGENT. MESSAGE:· ....___ 0 Please Reply - PAGES:.Q CC: 0 Please Review 0 Please Recycle 30101-70 Business Loop, Grand Junction Colorado 81504 (970) 254-0460 office (970) 254-4694 fax morstorage@bresnan.net '. ·-------------~-----------------------' Jul 18 08 11:53a 970-254-4694 ., . · ~ ~ ~. ~ ..... ~ ·• .. "" ...... .... ~ ·~ ~.t' 'io ~ ">'0 l ., i-1' -(.. .. 1) t. ... '"' ... "!\ ..... ..,. u .. ~ '--"'. p.2 :.: -:·..:· . ; ~-- ' .··-:.-. ·;: .. -~-. .. . :. " •... · .. . .. :_ ~ _, . : .. • . ... -· ~ t.J_ · . --~- . :. :;.-- _ .... '. -·· · .. •. . ::: .-.. . r ••• ·- :·.;j --~ _{/) .':~- ' . : . -; ~ .· ' (5".:;· c ' . ..... ~-:;,· -I . . . . I + I + I I ' + I + I . + I iL-------:J l1.7'----_:_---~ Center 114 Comer Section 25 An Aluminum BLM Cap --------- ------- PPROVED SVBJEcr TO NOTED EXCEmONS & INSPECTIONS GARFIELD COUNTY ,~~~NT LDCOPY NO INSPECTION WITHOUT TIIE8E PLANS ON SITE 237.5' page of .s· PVC Riser ----. ---- -- Telephone Peel~~ -- --- 3 r·;.; n·· X r'6H OSB GUSSET Wj(::l) thl HAILS I'I!:R TRUSS ~EMBE:R-T'IP!Ql. EACH-. SlllE '\ -'- 16'' X 6'" X OJ" OSB .. ___ '·, GUSSI::T W/(5) 6d NAILS PER TRUSS MEMBER-D"..e.l£A.\ .. ~;Ak!::l SlDE 3 !" X 16" X t," OSB GUSSET W/(5) 8d NAILS PER TRUSS MEMBER-'I'YPICAt F.t\CH '"-, 3' -11~" x-/ ----'-'~Q SIDE \ ]'-jjl" \ ~-·-8 1.........--:--- \ 6" (2)2x4 TOP PL 3 !" X 8" X ~-OSH GUSSET W/{5} Bd NAILS PER TRUSS MEMBER-T~ SI...!2E TYPICAL TRUSS NOTE:GUSSETS ARE Nt--.iLED TO BOTH SIDES OF TRUSS AT (ACH INTERSECTJON 14-' L__ __________________________ . __ BLOCK EVERY OT!IEI~ OAY OF TRUSSES NAIL BLOCKING TO TOP PL WlTH (5) !60 NAILS. ATTACH TRUSSES TO BLOCKJNG WlTH (3) 160 NAILS. 1--., .I MATERIAL: HEM FIR N 0. 2 j 5.PACING ·-24 .. O.C. i ALLOWABLE LM.DING I ~ LL 50 PSr: ------1· .. 1 DL 10 PSF WL -75 MPH ' ' ! ! E,· • • e ... 0 0 "' :.,. ' l l ' --------------------1.-'--' "0''-'-' ~· 0 . ..- T Y PICI:'\l SEC.T lt>r~\ ~ 1\' ¥1 i \".:.l ~ G'E 1':1 li:l ';;.;_; __ 1 _____ _ ""..-,,.:, ;;_ J( 4 +·X 4 :>\~105-15'-o'' C.OH"C l..\!.I·JE:>i 'r\ Mor Stora_ge Seles Inc. ~ 30101-70 B'uslness Loop_ .... , GrandJunctlofl..Cp81504 · .. · ·-· Fax 970.2::>4-'t694 .~ . v69trV9l-OL6 ·-I~ lo '-()" " 2..:1· (,. ·:~ .