Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Stree~ Suite#401 Glenwood Springs, Co. 81601 Office:970·945-8212 Fax: 9711-3114-3470 Inspection Line: 9711-384-5003 Building Permit No. __ \I 08')-1__!___ Parcel No: 2393-051-07-037 ------ Locality: Los Amigos Ranch Fig 5 Ph II Lot 5~------- Job Address: 0243 Crescent Ln. GWS Use of Building: s/f dwelling on partial crawlspace w/cov. deck and alt. gar. Owner: Rockwood Shepard ________ _ Contractor: Owner ----"-'· '------· Fees: Plan Check: $ 1,504.98 Septic: ------ Bldg Permit: $ 2,315.35 Other Fees: Total Fees: $ 3,820.33 Clerk: ~DlUfECYL Date: ~I w )OX I GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8'" Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384-3470 I Inspection Line: 970-384-5003 www.garfield-county.com Authoritv. This application for a Building Pennit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple sepamte pennits may be required: (I} State Electrical Permit, (2) County ISDS Pennit, (3) another permit required for use on the property identified above; e.g. State cr County Highway/ Road Access or a State Wastewater Discharge Pennit. Void Permit. A Building Pennit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certifY that I have read this Application and that the information contained above is true and correct. I understand that the Buildi11g Department accepts the Applicatioll. along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting pennission to me, as Owner, to construct the strncture(s) and fi1ci!ities det1likd on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Buildir.g Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County. if the ]()~arion. construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable Jaw. I hereby grant pennission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Penn it does not prevent ti~~ Building Official from: (I) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or usc of the structurc(s) or faci!ity(ics) if such is m vi<)lation of County Regulation(s) or 1 · law. Review oftl1is Application, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omis.~ions o\i~d•~·.o~re~p~on~d~";,·~A~;'~th~,~~OilwF,n:";[· ~~~~:~;~::~·~"~'~p;onsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, Al)f') UNDEW;TA.ND• TillE '101'ICE & CERTIFICATION ABOVE: S-6 STAFF USE ONLY Special Conditions: ~~~~~ Adj~sted Valuation: ?3~971) '<(t, /5<D"l ::1~ Plan Check Fee: Permit Fee: 27-J/~. 31'5 Manu home FN /fl Mise Fees: W l/l ISDS Fee: {'J { f4: Total Fees: Ji 10.)) Fees Paid: Balance Due: Setbacks: OCCGroup: Const Type: ,----,J>'"' B I>G~t P NGDF}'~ ... (. ~ APPROVAL') DATE APPll,OV!\1 ..) DATE l I The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified in the Building Permit. DATE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date _::R7o:;ockw~o:;:o;:::d~S:::ho::e~par=d==---'----Subdivision .::0.:::24-"3'='C.:::r:..:e:;:se:::n::ct.::L:=an::.:e::c, ,::G:_:W,;,;S:;;_ _____ Lot/Block .:::3=0-.::M:=:a::;Y:..;-0,8'--~--'--------Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Valuation Crawl Space Valuation Decks/ Patios Valuation Covered Open Type of Construction: Occupancy: Valuation Total Valuation 2557 sf sf 1520 sf sf X $74.68 4077 sf sf X $41.00 sf X $33.68 684 sf X $18.00 308 sf X $9.00 684 sf X $24.00 sf X $12.00 Commercial sf X sf X sf X sf X sf X sf X ElkSprings ~ (\I'~ 6' Ph , J.. 56 Owner 304,47036 0.00 12,312.00 2,772.00 16,416.00 0.00 335,970.36 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. · Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with 1 decks, balcony, steps, handrails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be ·designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that' identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure( s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes X • 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes X 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), strearns or water courses? Yes tJ /A: -flub it~ S0we1 f u .. M:fe<' I 4. Does the site plan indicate the location and direction of the County or private road accessing the property? 2 Yes X 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a driveway access permit or obtain a statement from the Garfield County Road & Bridge Department stating one is not necessary? You can contact the Road & Bridge Department at 625-8601. Yes )<.' 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes X ' 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes X 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes X 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes X 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes X 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes X 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes X 13. Does the elevation plan .indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) ~ X . 14. Does the plan include any stove or zero clearance fireplace planned for installation including 3 15. 16. 17. 18. 19. 20. 21. 22. 23. make and model and Colorado Phase II certifications or phase II EPA certification? Yes ~ No---,--.,--,----, Does the plan include a masonry fireplace including a fireplace section indicating design to ~:ply with the IRC? No )\ }J /f.. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes No ______ _ Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes X No _____ _ Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tnb enclosures and specifY safety glazing for these areas? Yes ,X No _____ _ Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes )< · No ____ _ Do you understand that if you are building on a parcel of land created by the exemption · process or the subdivision process, are building plans in compliance with all plat notes and/ or covenants? Yes ''>( No _____ _ Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Departtnent prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes X No ------ Will this be the only residential structure on the parcel? Yes X No Ifno-Explain: ______ _ ~::_e_t~')5~o-(_2_l_c_o_m_plete sets of construction drawings been submitted with the application? 4 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes X No ___ _ 25. Have you designed or had this plan designed while considering building a,ud other constl"l.\99on code requirements? Yes ~ No ____ _ 26. Do your plans comply with all zoning rules and regulations in the County related to your properti.f~ zone district? Yes }\ No _____ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspecti9n py the Garfield County Building Department? Yes ~ No _____ _ 28. Do you understand that approval for design and/or construction changes are required prior to the aR]Jljcation of these changes? Yes X No ____ _ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes 'X No ____ _ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be calle(l in to 384-5003. Yes ?G No _____ ~ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes No ----- 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes '),.! No ___ ~-- 5 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the patty responsible for the project must comply with the IRC? . Yes X No ________ __ 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you· as the homeowner are performing the work? The license number of the person performing the work will be · required at time of applicable inspection. Yes No. ______________ _ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a buiJdmg permit application? Your attention in this is appreciated. Yes 2S No ________________ __ 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes )<' No · (please check with the building departtnent about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the propetty prior to issuance of a building permit that you will be required to obtain a grading permit? Yes X .38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes X I hereby acknowledge that I have read, understand and answered these questions to the ~£ s~e of Owner . Date Phone: q7o-so'!-(93b (days); __,Se:::O.c:_\fY'4..'-'-"''--------( evenings) Project Name: S he.po.rd l?.esl~\1\U.. ProjectAddress: 0?-'-\-~ C(·esc..e~~~._f Lo.Vle.l (Tlt'vtWood Sp(Gl'I\Ss <6{60{ Notes: If you have answered "No" on any of the questions, you may be required to provide this 6 information at the request of the Building Official prior to. beginning tbe plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined hy tbe Building Official that additional information is necessary to review the application and plans to determine minimum compliance with tbe adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Bpminreq November2006 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 4~to 7000ft. elevation. ~.:2!-o~£S.E.:ZOt:..ty_y..j(l!,..<;tii""2QQQfb 75PSF 8001 to 9000ft. lOOP SF 9001 to 1 OOOOft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Dept : 36in. to 8000ft. elevatio 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000 .; lninus 16 over 7000ft elevation. Air Freezing Index: Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: p.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • Basement wall R-values are R -10 be!'ow grade, R-19 above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-10 below grade and R -19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. PLAN REVIEW CHECKLIST Applicant&.f..tf./2 j Building _/_En ngineered Foundation _/{/{Driveway Permit ~veyed Site Plan ~. f_ .J:1..A_septic Permit and Setbacks --~rropography 30% ~ttach Residential Plan Review List -~nimum Application Questionnaire ~bdivision Plat Notes tfil.Fire Department Review ~ __ Valuation Determination/Fees ~Line Plans/Stamps/Sticker ;{.44..Attach Conditions ~plication Signed ~ Reviewer To Sign Application ~eel/Schedule No. df!_ 40# Snow load Letter-Manf. Hms. /soils Report GENERAL NOTES: Date b-2.. -D7J Planning/Zoning ~operty Line Setbacks 1./ I/30ft Stream Setbacks ;./-f). Flood Plain ~Building Height ~gSign-off ~Road Impact Fees .H.if.;HoA/DRC Approval -~rropography 40% d,dPlanning Issues ~vision Plat Notes N 11087 o. --------------------Assessor's Parcel No. 2393-051-07-037 Date 9/4/2008 BUILDING PERMIT CARD Job Address ----~0~2~43~C~re~s~c~e~nt~L~n~.0G~W~S~/~L~o~s~A~m~i~o~s~R~a~n~c~h~fi~.~5,~1£0t~5~6~L(~~~~~~~L_ ____ __ Owner ________ --=S:.::..h:.::.e"'-pa.:c::r:.::.d"-, .:..:R:.::.o:.::.cl:.:..<w:.::..o.::...o.:..:d:.:.._ _____ Address 0243 Crescent Ln. GWS Phone # 970-309-1936 Contractor _______ o_w_n_e_r _______ ~-----Address ___ S_a_m_e ___________ Phone # ____ _ Setbacks: Front ______ Rear _____ RH ________ LH _________ Zoning ________ _ s/f dwlg on partial crswp w/cov deck & att gar INSPECTIONS Soi Is Test -_,..---=---=::-----=::-------- Footing-t-6,-E':fP Cf---2.'9 -o5? ~A./. *Foundation /t'-2-Z--c?'JJ 0c.J ' Grout _____________ ~~--=~~~ Underground Plumbing !i?-3-t::?/?~ Rough Plumbing ---------------Framing ____________________ _ Insulation ------------------ Roofing------------------- Drywall-------------------- Gas P i_p i ng -----------,--:-:c----.,.--:::, -t"Fcx5[1C~5 rl'/ Ft:.oo/( ;I-/'J--o.s'y.U? NOTES Weatherproofing _______________ _ Mechanical ___________________ __ Electrical Rough (State)---------- Eiectri,9~~Final (State) ' Final k+-/() /Checklist_ Co111pleted? l2fVt Certificate Occupancy #_ { tJ430 Date Iss lLE"t) 2... I J. I D Septic System # -------------------- Date ---------------------Final __________________ _ Other ________________ _ (continue on back) BUlL INGP RMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Date lssued __ Of_._·_'/_,__·,.ce""'-'..,..'----------Permit No. _j__._I..,QB~....,,_:J:_._ ________ _ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. use_-:5Jf on pnfioll cra.wls~ce wtcov. dtx:.i!.~ a.tt. o/1~...._ ... _ Address or legal Description ~3 CKt:5Cf:Jfl_,_f-__.\..n.,"-"-'.'---->.G..,."l._W._._S""---------- Owner ~cJLWOOO "d contractor _.,.Q'-"-w-"-"ner-""'"---------- Building Permit Type ~e:s l entit.d This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footin!JI Driveway r BA! c:wlf! £) '7-2-9-oS ~J Foundation I Grouting /0 --z_·z_ o 13 'f/U..: Insulation 1/-~-0 7 c:;zr:v: f"'oJT/Z.S ;;I ;::'Lc;ofl_ i/··/f-c>i> ~tJ. Underground Plumbing Drywall /1-/''-o't 4???/ /;1.-3·0'/';~ Rough Plumbing /&--z:z 0 '? f?'k/:' Electric Final ty State Inspector f o L ;¥ ;;v, 11 or (Prior to Final) Rough Mechanical Septic Final Gas Piping 1/-Z-o'? 'f?41 FINAL 4'-f/to ~ . Electric Rough (by State Inspector) (You Must Call For Final Inspection) . o[c. 6r 7/!!·fot Notes {Prior to Framing) Framing ;o-·zz-o 7' <j<C</ \ V£tNI.£s:; $A..SIZ:: $;L0;:(oo/ff (to in dude Roof in place & Windows & Doors installed & Firestoppingln place) THIS PERMIT IS NOT TRANSFERABLE For inspection Call970-384-5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ADPatPeROVEP'Jo • t f .ffl _. ) ~ __ 11.>]..__:"'1_.__,~""--"='"------By -1-'. dACVWAn ~ PROTECT PERMIT FROM WEATHER DA AGE ~(<;_) ~~ (DO NOT LAMINATE) COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at _oc_·_Z:____c'f-_3=·"-------"C~NL<CI~==-=· -=~=· =-=-· __,_l __ L.;;_:;N-"'--. Permit No. --"-~-f-/-=d'--f5_7 __________ _ I have this day inspected this structure and these /:J premises and found the following corrections needed: -!" HAOs/1 Ai4/L P/Am:s · ~ /d/L.L. /L&w /£s/ ~£5 77(/f/'9> <'7'\ Arl/Z: ~ / /VS" n c.. c 3J ;? Y/1 fit.t'S / r7zii/TS /V'£ ;C 0 ;;r;y .. 23£ A77/icd£P f?!;?£c7ZY7;3 ot//5/PL 6}_ GAs t/AL'1L.-z:s #JC£0 7 ?7J 23£ , .. / /(c c£5'.5'/ ZJV:: . · ~s-;~77[t;...s:s hA/l!S ,A/.£4-P 7'C 15£ ;;-,_ON S/7/t: ij;e_ //V..:s·r:_ :&v'.EA/s. /b V£".K';r)1 ALL. /1£/-IPIC:f? 5 .-../14'r 7& .sr£" c-:s · ZJ Af?;C V 23"/Z'AM 13Mc/-(/&0 0 Call for Re-lnspection . //£.111/i:.lf! U/,!AfOo 1-U S 0 $50.00 Re-lnspection Fee must be pa1d priarfo Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 9'-/ ~-20 0 9' Buildi~nspector ~/ ~~-- Phone (970) 945-8212 COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at 0' Z -f..-:3 . Permit No. 1 /jc:? 0 7 I have this day inspected this structure and these premises and found the following corrections needed: e('6;11 for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. "'" S'-_:::;~ B o ~ Building Inspector~<? · {:(;~ Phone (970) 945-8212 TO: From: Job: Project No.: Date: ODDO ENGINEERING, INC. MEMORANDUM Rocky Shepard Landon Anderson P.E., Oddo Engineering, Inc. Shepard Residence Lot 56 Elk Springs 2800-20 September 24, 2009 oddo I l q .. ·· ... ·\ :r'\8 q\ Regarding headers for the subject project it is acceptable to use (2) 11 7/8" TJI-360 for spans not exceeding 6' -0". Reference detail 2/ S4.1 for additional information. The header shall be located directly under the wall top plates. Feel free to contact our office for additional questions. DOCS\!ka\shepard memo !.doc 713 Cooper Ave., Suite 200 +Glenwood Springs, CO 81601 (970) 945-1006 +Fax (970) 945-2966 +E-Mail info@oddogws.com Parcel Detail Page 1 of3 Garfield County Assessor/Treasurer Parcel Detail Information Ass~,ssor/Tre&s1!rer Propeny_S~arch I Assessor Subset QJ.!e!JC I AssessoLS<!lesSearch Clerk & Recorder.Re~tion Semel! ll&sic Building_ChMJ!Cteristi_cs I Tax Information Parcel D,etail I Yal1le Detail I Sales Detail I ResidentiaJ!Commercial ImnroYe_ment Detail ,Land Detail I Photogmp_hs I Tax Area II Account Number II Parcel Number /1 2007 Mill Levy I I 012 II R120063 II 239305107037 II 64.843 I Owner Name and Mailing Address !SHEPARD, ROCKWOOD & DEBRA IPOBOX6755 !SNOWMASS VILLAGE, CO 81615 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:5-7-88 SUB:LOS AMIGOS !RANCH FL 5 PH II LOT:56 PRE:R120030 IBK:0650 PG:0574 BK:1936 PG:0914 IRECPT:725377 BK:l936 PG:0912 IRECPT:725376 BK:1936 PG:0910 IRECPT:725375 BK:1936 PG:0908 IRECPT:725374 BK:1936 PG:0907 IRECPT:725373 BK:l386 PG:411 IRECPT:610700 BK:1186 PG:323 IRECPT:563168 Location Physical Address: licARBONDALE S bd . . . IILOS AMIGOS RANCH FL 5 PH U IVISIOU: II http:/ /www.garcoact.com/ assessor/parcel.asp ?Parce!N umber=23 93051 07 03 7 I I I I I I I I I I I I I 6/3/2008 Parcel Detail Page 2 of3 I Land Acres: 112.66 I I Land Sq Ft: 110 I Section II Towns hi~ II Range I 5 II 7 II 88 I 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 130,000II 37,7001 I Improvements: II OJI 0 I Total: II 130,000II 37,7001 Additimtal Value De:tail Most Recent Sale Sale Date: 11616/2007 Sale Price: 11175,000 Additional Sales Detail Basic Building Characteristics Number of Residential 0 Buildings: Number of Commllnd 0 Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type II Amount I I 2007 II Tax Payment: First Half II ($1 ,222.30)j I 2007 II Tax Amount II $2,444.601 I 2006 II Tax Payment: Whole II ($2,529.80)1 I 2006 II Tax Amount II $2,529.80/ I 2005 II Tax Payment: Whole II ($2,540.12)1 I 2005 II Tax Amount II $2,540.121 I 2004 II Interest Payment II ($24.91)1 I 2004 II Interest Charge II $24.911 II II http://www. garcoact.corn/ assessor/parcel.asp ?ParcelN umber=23 93 051 07 03 7 6/3/2008 Parcel Detail 2004 II Tax Payment: Whole II ($2,491.3021 2004 II Tax Amount II $2,491.301 2003 II Tax Payment: Whole II ($2, 116.64)1 2003 II Tax Amount II $2,116.641 2002 II Tax Payment: Whole II ($2,057.80)1 2002 II Tax Amount II $2,057.801 I 2001 II Interest Charge II $20.681 I 2001 II Tax Payment: Second Half II ($1,034.2321 I 2001 II Interest Payment II ($20.68)1 I 2001 II Tax Payment: First Half II ($1,034.23)1 I 2001 II Tax Amount II $2,068.461 I 2000 II Tax Payment: Second Half II ($958.5721 I 2000 II Interest Payment II ($9.5921 I 2000 Interest Charge II $9.591 2000 Tax Payment: First Half II ($958.57)1 2000 Tax Amount II $1,917.!41 1999 Tax Payment: Whole II ($1,786.0221 1999 II Tax Amount II $1,786.021 Top of Pa.g~ Assessor D~ttlLlLase Search O:ptiQlls I TreasurerJ2.fltabase Se!irchDptiQ!:l.ll Clerk & RecorderJl<!tabase Se!irch.D_ptions Page 3 of3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turu$BoJtwan;. http://www. garcoact.cornl assessor/parcel.asp?ParcelN umber=23 93 051 07 03 7 6/3/2008