HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-3-16-4091, SEPT 3-16-4092 Butler-Tilley New SF Home @ 6 Silver spruce Dr. Carbondale, CO 1) SEE PLAN ATTACHMENTS FOR BUILDING REQUIREMENTS . 2) OPEN -HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION , 2500 PSF . 3) PER PLAT NOTE, A LOT IMPROVEMENT CERTIFICATE IS REQUIRED AT FOUNDATION INSPECTION TO VERIFY BUILDING LOCATION IN ENVELOPE, SEE DETAILS PAGE AOOl. 4) LOCAL FIRE DISTRICT SHALL INSPECT INSTALLATION OF FIRE SUPRESSION SYSTEM . PROVIDE A ROUGH IN APPROVAL REPORT AT FRAMING INSPECTION . A FINAL APPROVAL REPORT IS REQUIRED FOR FINAL/CO INSPECTION. 5) IF APPLICABLE, PROVIDE ENGINEERED FLOOR TRUSS SHOP DRAWINGS AT FRAMING INSPECTION, LIVE LOAD@ 40 PSF PER IRC, TABLE R301.S. 6) IF APPLICABLE, PROVIDE ENGINEERED ROOF TRUSS SHOP DRAWINGS AT FRAMING INSPECTION, TCLL@ 40 PSF . 7) A HEIGHT ELEVATION SURVERY IS REQUIRED AT FRAMING INSPECTION TO VERIFY MAXIMUM BUILDING HEIGHT OF 25 FEET .