Loading...
HomeMy WebLinkAboutSubsurface Investigation and OWTS Design Report 04.11.16A LL • 3 Four Wheel Drive Rd Carbondale. CO 81623 . 970·309·5259 ~rn~l~I h r I r April 11, 2016 Nancy Carlson njbcarlson@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 2780 Cattle Creek Road Garfield County, Colorado Nancy, Project No. C1197 ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 13.83-acre property is located outside of Carbondale, in an area where OWTSs and wells are necessary. Legal Description: Lot 13 of Section: 10 Township: 7 Range: 88, Garfield County, Colorado SITE CONDITIONS A 5-bedroom, single-family residence and barn currently exist on the property. The existing residence was initially a 3-bedroom home and two additional bedrooms were added by a previous owner. The existing barn includes a partially-finished studio space on the upper level. There is a desire to upgrade the existing OWTS to accommodate the 5-bedrooms in the residence and to install plumbing in the studio space above the barn which is intended for use as a hobby room (canning). A spring, located greater than 50-feet from the proposed septic tank and greater than 100-feet from the proposed soil treatment area (STA), serves potable water to the property. The proposed STA location has approximately a ten percent slope. The site slopes to the southwest toward Cattle Creek. Cattle Creek is located greater than 50-feet from the proposed STA. SUBSURFACE The subsurface was investigated on March 16, 2016 by digging two soil profile test pit excavations (Test Pits). A mini-excavator was used to excavate the test pits. Visual and tactile soil analysis was completed by Caria Ostberg at the time of excavation .1 The materials encountered in the Test Pit #1 consisted of slightly moist to moist, medium brown loamy sand to a maximum depth explored of 8-feet. Cobbles approximately 2 to 4-inches in diameter were observed below 6-feet. No bedrock or groundwater was encountered. A tactile analysis of the soils was taken from Test Pit #1 at 3-feet below grade. The soil formed a ball, but did not form a ribbon. Soil structure shape was granular to blocky, soil structure grade was moderate to loose, and consistence was loose to friable. 1 Caria Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 2 The materials encountered in the Test Pit #2 consisted of slightly moist to moist, medium to reddish brown loamy sand to sandy loam to a maximum depth explored of 8-feet. Cobbles approximately 2 to 4-inches in diameter were observed below 6-feet. No bedrock or groundwater was encountered . A tactile analysis of the soils was taken from Test Pit #2 at 3-feet below grade in an area outside the existing STA. The soil formed a ball and a ribbon less than 1-inch in length before breaking. Soil structure shape was blocky, soil structure grade was moderate, and consistence was friable. Texture of the soil was more gritty than smooth. We are proposing the STA in the area of Test Pit #1; therefore, we have classified the soils in this area as Loamy Sand. STA sizing is based on Soil Type 1, Loamy Sand. A long term acceptance rate (L TAR) of 0.8 gallons per square foot will be used to design the OWTS, in accordance with Table 10-1 Soil Type 1 presented in the Garfield County On-Site Wastewater Treatment System Regulations, adopted April 14, 2014. Test Pit#1 Backfill Page 3 ... Sieved sample . ·•· ~=· -q' .. :-.. ~s ~.,.: .. ~~~,,_.. ~ ,··.; -J,C_~F_:.;"t~ ~: Test Pit to 8-feet Page4 Page5 DESIGN SPECIFICATIONS The existing septic tank serving the main residence will be properly abandoned in place by collapsing the top and sides of the septic tank and filling the remaining void with gravel, sand, or compacted soil. OPTION: The existing STA may be located by running a camera through the existing septic tank outlet. If desired, a Bull Run Valve may be installed which would allow future use of the existing STA in the case of an emergency. If this is not desired, the existing STA may be abandoned in place. Desjgn Calculations: Average Design Flow= 75 GPO x 2 people x 3 bedrooms+ 150 GPO (41h -51h bedrooms)= 600 GPO 600 GPO+ 150 GPO (studio/hobby room)= 750 GPO LTAR = 0 .8 GPO/SF 750 GPO I 0 .8 GPO/SF x 1.0 (gravity trenches) x 0.7 (chambers)= 657 SF 657 SF/ 12 SF/chamber= min. 55 chambers The system installation will include a new 1500-gallon, two-compartment septic tank to serve the main residence and a new 1000-gallon, two-compartment septic tank to serve the studio/hobby room above the barn. Effluent filters must be installed on the outlet tee of each septic tank. Effluent will gravity flow with a minimum 1 % grade from each tank to a distribution box, which must be accessible from grade. The STA will consist of two rows of 19 'Quick 4' Infiltrator® chambers, one row of 9 'Quick 4' Infiltrator® chambers, and one row of 8 'Quick 4' Infiltrator® chambers. The two shorter rows will be served by the same outlet from the distribution box and connected either with a level manifold OR with an additional distribution box. Inspection ports must be installed at both the beginning and end of each trench. There must be at least 6-feet of undisturbed soil between each trench. We recommend fencing around the STA to prevent tractor traffic in this area. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs. and any other components needing maintenance. Geo-fabrics or plastics should not be used over the absorption area. No heavy equipment, machinery, or materials should be placed on backfilled ST As. Livestock should not graze on the ST A. Plumbing fixtures Page6 should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions 'should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS : The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation . Please call with questions. Sincerely, ALL SERVICE septic, LLC (I [tJ.-i. {{t 051-/iu,_ g Carta Ostberg, MPH, REHS Reviewe d By: ~-t\ ") ~\"'\ J N ~ ~ >C o· 20' 40' Salle: 1· = 40'-o" IC .. >C IC DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 04111/16 I ALL ~lHml 33 FOUt Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 earla @aaservlcesepcic.com -----·~ 224. 7' • --== .. i--- PARCEL A 9.26 acres+/- ~~~~~~~~~ISTING I 'L:::::--'9 . _ EXISTING . I' _'.....~ l 1 J.k-, -.........._ STATQ~ \ -......,\REMAIN "\I~~ ~s· Pl'I'-~ I ""' I I I \ x--x-1-x /'-·----t ---. ~~ TEST -PIT#1 amRAL \ -1:JfRN ''-----·-.~ {i) SITE PLAN "' s Carlson Residence 2780 CR113 Ga<li elO County, Color.Ida Projed Number. Cl197 BARN WITH STUDIO/HOBBY ROOM x ~ c;:j ~ - PARCEL B 4.57 acres +/- 121.4f Elev-627aoo· ) "@ Dato: 04/11/16 Oasign9d By: CB; w 1 . 0 Reviewed By: RH Drawn Bv: ANG Sheet 1 of 4 \~ ~~~~~~ ~ L_J\ ' '"" "' 4• DIA SDR-~NSPECTl d~ PORT AT BEGINNING ~D END 01': EACH TRENCH \ \ '-oUICK 4' CHAMBER\TRENCHiis.~ lWOROWS OF 19 CH~MBERS, \ ONE RpW OF 9 CHAM~RS ANO ·\ CHAMBERS u 660 SF f ONE~ OF 8 CHAMBE)S = 55 \ .! I . ' I \ it-r-----l r-----..> -x--- N -r~ ~ . ~ "\ 10' 20' + NOTE; RELOCATE FENCE WEST OF STA r ""'' ,..,...,. \ f,'l OWTS PLAN ALL ~mm 33 Four Wheel Drive Road Cartxmdale, Colorado 81623 Phone 970.309.5259 carla@allserviceseplic.com Carlson Residence 2780 CR113 Gattie Id County, Colorado Projed Number: C 1197 J -I I I 4" DIA SOR-35 -4------INSTALL BULL RUN VALVE. IF DESIRED SEWER LINE WITH DOUBLE-SWEEP CLEAN OUT (MIN 2%SLOPETO TANK) 1500-GALLON, lWO·COMPARTMENT SEPTIC TANK WITH EFFLUENT SCREEN 4" DIA SDR-35 SEWER LINE (MIN 1% SLOPE) YSEWERLINE SEWER LINES FROM EACH TANK INTO D BOX ~4" DIA SDR·35 SEWER LINE (MIN 1% SLOPE) _J I 1000-GALLON. lWO-COMPARTMENT. CONCRETE SEPTIC TANK WITH EFFLUENT 'Y / SCREEN J I 4" DIA SDR-35 SEWER LINE WITH / +llfl DOUBLE-SWEEP CLEAN OUT (MIN 2%SLOPETO TANK) .. Dale: 04/11116 Designed By: CB, W2. Q Reviewed By: RH Drawn Bv: ANG Sheel 2 of 4 ALL ~mm ~~ f1'i STA SECTION 4' DIA INSPECTION PORT GRAVELLESS 'QUICK-4' CHAMBER (4' • 3") INFILTRAT• ,JO t -~_Jz=~r;= l.Z 34' UNES TO ENTER AND EXIT IN TOP PORT OF CHAMBER END PLATE SMALL VALVE COVER BOX OR IRRIGl\TION VALVE BOX AT GRADE ATTACH CAP OR THREADED ~AA ~-li;;,• CLEANOUTASSEMBLY . ,. USE HOLE SAW TO ~~~~~~v ""'"Ill"" »LI 4" PVC PIPE CUT TO FIT {j) CHAMBER DETA,L~~au~• INFIL TRA.TOR END PLATE INSPECTION PORT AT BEGINNING AND ENO OF EACH TRENCH GRAVELLESS 'OUICK-4' CHAMBER (4' • 3') -------36'---------> 33 Four Wheel Drive Road Carbondale, Colatado 81623 Phooe 970.309.5259 ca~a@allservlcesepUc.com &CHAMBERS ------32'------' f2'I STA PLAN .a __ PIPES PLACED IN TOP PORT OF CHAMBER END PLATES 11 4• DIA SDR-35 SEWER LINE LINE FROM TANKS DISmJBUTION BOX WITH ACCESS AT GRADE 'DIA SOR.;JS SEWER LINE (MIN 1% SLOPE TO mENCH) Carlson Residence 2780 CR113 Garfield County, Colorado Projec1 Number: C1197 NOTE: MAY BE INSTALLED BELOW GRADE IN A VALVE BOX ACCESSIBLE Ai GRADE 'f' 't 't l(' 'ifE' 4" DIA OUTLET SCREW-ON, WATER-TIGHT ACCESS CAP ACCESSIBLE ABOVE GRADE VALVE DIRECTION HANDLE 4" DIA OUTLET (4) BULL RUN VALVE _DETAIL Date: 04/11116 Designed By CB~ w 3. 0 Reviewed By: RH Drawn By: ANG Sheel 3 ol 4 SllP·ON PVC CAP DONOTGl.UE INSUlA TED COPPER TRACERWlRE 4" DIA SOR·35--- SEWER LINE TO TANK TO HOUSE (i) CLEANOUT DET!\lnm DESIGN 5-BEOROOM RESIDENCE BOX ANO COVER BROUGHT TO GRADE l ~ C NCRETE LIO FINSHED GRADE I \ lo ~,OL±."'°" DISTRIBUTION BOX ANGLED PIPE (i) 0-BOX OET AIL TOBE USED AT INLET 0 2 3 (75 GAUPERSONIDAY x 2 PERSONS/BEDROOM x 150 GAUOAY 4\h AND Sth BEDROOMS I• 600 GAIJDAY 4 STUDIO I HOBBY ROOM CONSERVATIVELY ESTIMATED" 150 GAUDAY WASTEWATER FLOW• 600 GAllDAY + 150 GAUDAY = 750 GAUDAY TANKS: 5-BEOROOM RESIDENCE •MIN. 1500 GALLONS STUDIO I HOBBY ROOM • MIN. 1000.GALLONS SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) "0.8 GAU SQ FT CALCULATED STA• OIL TAR= 750 I 0.8 = 937.5 SF GRAVITY, CHAMBER TRENCHES= 938 SF X 1.0 X .7 = 658.25 SF 657 SF/ 12 SF I CHAMBER: MIN. 55 CHAMBERS ALL 1mm 33 FOU< Wheel Drive Road COlbondale. Colomdo 81623 PhOne 970.309.5259 earla@alsenticeseplic.com 5 6 7 8 9 10 Carlson Residence 2780CRl13 Garfield Counly. Colorado Project Number: C1197 SLIP·ON PVC CAP DO NOT GLUE STAFILTER~~ MEDIA ~ SPRINKLER VALVE BOXATGRAOE 1/4" DIA HOLE DRIU.ED INTO TWO SIOES OF PIPE FOR VENTILA TlON (BELOW SLIP ON CAP> (3) INSPECTION POJ!!J?Ef All SOIL PROFILE TEST PIT NO. 1 SOIL PROFILE TEST PIT NO. 2 ':::.;· :·.·. ::~~} .. '."": SLIGHn Y MOIST, MEDIUM BROWN LOAMY SANO SLIGHn Y MOIST, MEDIUM BROWN TO REDDISH BROWN SANDY LOAM ~ piq topsoil F1 loamy sand NO GROUNDWATER OR BEDROCK ENCOUNTERED DURING TRACK HOE EXCAVATION n sandy loam (.i) SOLS LOGS .,., "'.,_, Date ; 04111116 Designed By: cs; W 4. Q Rovlewed By; RH Drawn Bv: ANG Sheet 4 ol 4 Item# IM·1530-2CP 1530 Gallon Two Compartment Infiltrator® Poly Tank TOP VIEW FIBERGLASS SUPPORT 2/JTOTAL VOL 113 TOTAL VOL SIDE VIEW • Compliant with CSA and IAPMO Standards • PVC risers ovoll oble • Secondary safety screen ovoiloble with PVC riser • Maximum burial depth is 4a• • Minumum burial depth is 6" • Tonk is not roted for vehicular traffic loading • Exterior of manhole cover includes the following warn ing: ·oANGER DO NOT ENlER : POISON GASES" Digging Specs Invert Dimensions 16 ' long x 7 ' Wide Inlet Outlet length Width Height Net Weight 43" below inlet 47" 44" 175.6" 61.7" 54.5 " 5 0 1 lbs. TANK TOP HALF TANK INTERIOR SEAM CUP (86) ALIGNaENT DOWEl.(41) TANK BOTTOM HALF @ MID-HEIGHT SEAM SECTION DETAIL SEAM CUP LIFTING STRAP (TYPICAl) END VIEW ~FILTRATOR . If/( IN suptlc 1anks lllJIAD,_IC. Net Working Capacity 1st Comp . 2nd Comp . Total 1006 gal 503 gal 1509 gal Water & 28Xl5 Ch Rd. 317 Wastewater (71I) 39M 7M P.O. BCDc925 0 VALLEY =~== Fax: (719)395-3727 BuenaVlsla,C0& 1211 0 PRECAST lac •Service Website: www.vaUeyprecast.oom ' • Emall: fi'ontdesk@valleyprecast.com Item# I M 1 060-2CP 24• ACCESS OPENING \ I INLET 1 19" 1060 Gallon Two Compartment Infiltrator® Poly Tank 127" -------- I Top View TANK TOP HALF TANK INTERIOR ALIGNMENT -' DOWEL(34) SEAM CUP (64) TANKBOTIOM HALF Mid-Height Seam Section Tank Includes Ilda sc.r ~ 1r 1ir nll Bulkhmt --------127" -------- • Compliant with CSA and IAPMO Standards • PVC risers available • Secondary safety screen ovoiloble with PVC riser • Maximum burial depth is 48" • Minumum burial depth is 6" • Tonk is not roted for vehicular traffic loading • Exterior of manhole cover includes the following warning: "DANGER DO NOT ENTER: POISON GASES• Digging Specs Invert Dimensions 12' Long x 7 ' Wide Inlet Outlet Length Width Height SEAM CUP (TYPICAL) LIFTING STRAP (TYPICAL) Net Capacit y Weight 47" 44" 127" 62.2" 54.7" 1094 gal 320 l bs End View f/T~ Fl L ~!!~~~~· msw.c. Water& (71I) 39M78' 2JDlSQ>.Rd.317 Wastewater P.O. Bcoc925 0 v ALLEY : =~: Fax: (719) 395-3727 Buena Vlsla, cos1211 0 PRECAST lac •Service Wabslta: www.valleyprecastoom ' • Email: flonldesk@valJeyprecast.com Residential Biotube® Effluent Filters Applications Our patented• 4-in. (JOO-mm) Biorube EHluenc Filters, Biotube Jr., Biorube Insert Filters, and Biorube Base Inlet Filters arc ideal for residential sepcic tank.~ and have a lifetime warranty. They prevent large solids from leaving the rank, Jramarically improving wastewater quality and extenJing the life of rcsiJcntial Jrainfidds. 4-i11. (I 00-111111 ) Biowbe Ejjlw:111 filter ~ .. .f-iu. (J00-111111} Bio111be Jr. {4-in. Biowbe mrtridgr t11"llil- flhle seprm11r6• ru /mat Filtrr) I r ( r 8-ill. (200-mm) Bme /11/rt F1/trr 4 -ill. ( /()(} 111111) lmert Filter • .. Or(llco 's mperior ej]l11e11t filurs resiu clogging lmtcr 1hr111 111/ othrr lm111d.r. Our Jlllll · d1trd, fit!l-sizetl 4-i11. (I 00-111111 ) Biowbe Efjl11el/f Filter prol'tt!es 11111.-..:111111111 l1111g-ter111 protcaio n iu rt wmpli:r.· prtckflge. ll'llh ho11s111g. Our -f-111. ( J00-111111) B111111br Jr., ttt hfl/f tht sizi: 11f1111r s1111ulflrd model, hm 11111re jilteriug cnprtcif)• tlJ/111 the fi11/-sizd jiltm wld b)' other 11111111tji1ct11ras. For trtnks l/lith existing 1111tlet tees, the Bi11t11be Insert Frlur is itlertl. Aud far lol/l·prujile t1111/.:s, there's the B11Sl' btl1•t Filur. To Order Call your nearest Orenco Systems , Inc. distributor. For nearest distribu- tor. call Orcnco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS·FT·1 Rev. 3.4 «> 11/10 Onnco Systemse, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean · ings. increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion-proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. Orenco Systems Incorporated Clw1gi11,( 1l1r w:r.r tl1r l\"'ar/d IJ11fl 1r:111mwrr www.orenco.com Nomenclatures ~in. Biotube Filter !standard) FT Q D 04 0 1 0 -010 Cf:lions: Blank = no options M = Uow modular on pbte installed A = Ilea! brackel auach <d Cartridge he:ytit: 2s· and 36" are stamlJrJ ousiny hciyht: 36" and 44" are stJntJard Filter diame:er (inches) W fits lYJJe 3034 outlet p:pe S fits Schedule 40 outlet pipe Blank ~ 118" liltralion P 1/IG" 1dlmlmn Biotube etlluer,t filler series 8-in. Biotube Filter (base inlet model) FT D 08 22 -1 1 4 Bl CJ:ons. A = lloat brackcl FS = 2' outlet or lice FSO = 2" outlet 01 lice and overllow plate• Base inlet model Carlrid9e hei9M 14' standard Housing height· 22· stam!ar J Fil!e1 d:ame!cr !inches) oa a· B!Jnk 118 · lillralion P 111 i " fijtralion Bio:ube effluent filter se1ies ·Also available wllh coupling and sleeve as a "kit": FT-OVERFLOWKIT ~in. Biotube Jr. (includes cartridge and housingl FT J 00 04 18 c=J w s 1 ~on s : Blank = no oplions M llow modulation pl.lie inslallell A -lloal bracket atlachcd CJr1ridge he19ht unches) Filter diameter 011Ches) fits Type 3034 outlel tee fits Schedule 40 oollel tee Blank = 118" lillrat1on P 1116 filtration Junior series Bioiube cfflucr.t filler series ~in. Biotube Riter Insert !cartridge oniyJ FT i 0 0418-0 -c=J 11 ~cus:omizcdop:ions te g. NC . ind:cates Nonh Carolina regions) W = lits lYJJc 3034 outlel lee S = f11S Schcllule 40 outlet tee canridge height (inches) Filler diamete1 fnches) Btmk 1 /8" li!lra1.an P = 1116" liltraiion lnsrn Bio!ube c1flucnl filler series 4-in. Biotube Effluent Riter ~in. Biotube Jr. Filter housing ---t 000 Tank wall ---+ Disrribuccd By: -Riser wall Item# DBox8C Concrete Distribution Box (1 inlet, 7 outlets) & Riser Top View Section View ----28" --25" ----28"--- 14" '® ® ® 0 ' Down Baffte I 7 " I ---28"-- End View I rrP •. 4 '4 -~ . . ·~· 4 ·· •a .,. . 15" . ' • ' ' ' . ' . I ' ..... ~ ... .· .~ 4 • . 4 ' . . ·~ ._ , • , A ._ 4 ' . . '112· Lid View • 6000 PSI Concrete • 7 Outlet equal flow Riser Section • Slide-in Baffle • 4• Pipe penetration ports ---28"--- ' .4 ' '• ..... ' . I . . ,4 . ' 4 . :. ,, I " , .. " ' 2" ... · . 4 . .<t l . . . 4 . • :. 4 . : : ~~ '. . .. ·4 .. : : ~ .. Side View End View • Connectors cast into the box • 12" Riser available Weight: D-Box with Baffle -200 lbs D-Box Lid -75 lbs D-Box Riser -140 lbs Water& (71I) 3IMJM 28Xl5Co.Rd.317 Wastewater P.O. Bo<925 0 VALLEY =~=: Fax: (719)395-3727 BuenaVlsla,OOa 1211 0 PRECAST lac •Service Website: www.valleyprecast.mn ' • Emall: frontdesk@valleyprecast.com 5.32 [ 13.5 cm J 04.49 [11.4 cm ] THIS WEIR SHAPE IS SELF LEVELING THESE RIBS PROVIDE FRICTION FIT FOR ALL 4" PIPE ID 1.73 .09 [4.4 cm J L2 cm J ~-t­ ~ 1.05 ·l J [2.7 cm ] +I --------+I POL YLOK EQUALIZER l PART NO. -3049 MATERIAL -FILLED POLYPROPYLENE rr INFILTRATOR'" water technologies (if;, Quick4 Plus 1 " Series The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch -wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connectionn" which permits turns up to 15-degrees, right or left. It is also available in four-foot lengths to provide optimal installation flexibility. The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength ----·. Quick4 Plus Standard Chamber -. . Specifications I Size 34"W x 53"L x 12"H (864 mm x 1346 mm x 305 mm) Effective length 48" (1219 mm) louver Height 8" (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.6" (15 mm), 5.3 " (135 mm), 8.0" (203 mm), 12 .7" (323 mm) .:Quick4. The Quick4® Plus Standard Chamber Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four-foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 lbs/axle with 12" of cover ~ ; ... ,., !· II I , I I \1 ' i \ '~ Quick4 Plus All-in-One 12 Endcap Benefits: • May be used at the end of chamber row for an inleVoutlet or can be installed mid -trench • Mid-trench connection feature allows construction of chamber rows with center feed , as an alternative to inletting at the ends of chamber rows • Center-feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 12 " raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical tlJJ i)\ APPROVED in -------------- Officials (IAPMO) ~ Quick4 Plus'"' Series -l/uick4. Quick4 Plus Standard Chamber------------------------------ -1------48" EFFECTIVE LENGTH Quick4 Plus All-in-One 12 Endcap PRESSURIZED PIPE DAILL POINTS LOCATIONS (2 PLACES) 13· l -------33·--------l FRONT VIEW Ouick4 Plus All-in-One Periscope --------- OUICK4PLUS (360• SWIVEL) / AU·IN-ONE PERISCOPE IT IN Fl LTRATOR waler tec111101og1es Q ;-s-1 4 Business Park Road PO. Box 766 Old Saybrook. CT 06-175 660-577-7000 ·Fax 860·577·7001 1-800.221 ·4436 www.lnflllratorwaler.com B"INVEAT SIDE VIEW INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The struclural integnty of each chamber, endcap and other accessory manufactured by Infiltrator ("Units1. when installed and operated in a leachfield of an onsite septic system 1n accordance with lnmtrator's 1nstruclions, is warran1ed lo lhe original purchaser ("Holder") against delective materials and workmanship for one year from 1he dale that the septic permit 1s issued for the septic system containing the Units; provided. however. that if a septic permit is not required by applicable law, lhe warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook. Connecticut within fifteen (15) days of the alleged defect. lnfihrator will supply replacement Units for Units de,ermined by lnfillrator to be covered by this Limited Warranty Infiltrator's liability specifically excludes the cost of removal and/or installation ol 'he Units. (bl THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTlCUl.AR PURPOSE (c) This Limited Warranty shall be void if any part ol the chamber system is manufactured by anyone other than lnmrator. The Limited Warranty does no1ex1end10 incidental. consequential. special or indirect damages. lnfillrator shall not be liable for penalties or liquidated damages, including loss of production and profits. labor and materials, ovemead costs. or other losses or expenses incurred by the Holder or any third party. Specilically excluded from limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident. misuse abuse or neglecl of the Units the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper siZing, excessive water usage, improper grease dispesal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void ii the Holder fails to comply with alt of the terms set forth in this limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder. the Uni1s, or any third party resulting from installation or shipment, or from any product liabihly claims of Holder or any third party. For this Limited Warranty lo apply, the Units must be installed in accordance wilh all site conditions required by Slate and local codes: all other applicable laws; and lnf1llra1or's installation 1nstriictions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty No warranty applies lo any party other than the origin;it Holder. The above represents lhe Standard Limited Warranty oflered by Infiltrator. A limited number of states alld counties have different warranty requirements. Any purchaser of Units should contact lnfillralor's Corporate Headquarters in Old Saybrook, Connecticut. prior to such purchase, 10 obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. US. Patents· 4 759 661 5.017 04 t. S.156.488; 5 336.017. 5.401 ,116· S.401 .459. S.511.903. 5.716 , 163 , 5 588,778 ; 5.839,844 C3nadian Patents: 1.329,959; 2,()().1,564 Othet ~tents pending. lnfiltra1or. Equalizer, 0..11ck4. and SldeWindcr arc registered trademarks o! lnhltrator Water Tcchnologies. lnl~trator is o registered tradem:irk in Francc. lnf1ttratorWa1cr Technologies is a rcgis1ered trademark in Mexico. Contour Microleachvig. Poly Tuff ChamberSpacer, MultlPort Posll.ock, OuickCut. OUickPlay, Sn:tpLock and Straigh1Lock are trademarl<s of lnF~trator Waler Tectmologies. PolyLok is a trademark of PoyLok , Inc TUF ·TITE 1s a registered troocmark ol TUF · TITE. INC . Ullra Rib is 3 traclcrnark of PEX Inc t:J 2013 lnf1ltrator Warer Technologies. LLC . All nghts reserved. Pnnted in U.S.A. PLUSOS 0713 Contact Infiltrator Water Technologies' Technical Services Department for assistance at 1-800-221-4436