HomeMy WebLinkAboutAs-built PlansTGC e — 56 5670 — TGC 1—erG� 7GC CO Proposed Electric, Gas, and Dry Utilities extension to preschool. Final rservice location to be approved by owner and utility provider. ----Er GC z �f TGC 4/4 — 2„ ----- 2„ 2" __ __— 2""] CT Distribution a 48" Manhole Section I w/ Cover r An On-site Wastewater Treatment System (OWTS) is intended to serve the proposed preschool facility at the New Creation Church, For wastewater design purposes, it is assumed that the preschool facility can accommodate up to 76 students and 16 staff. Since the preschool facility will not contain a full service cafeteria, the per capita wastewater demand will be 15 -gallons per day for students and staff, (CDPHE Regulation 43, Table 6-2, Rev. 6/2013). / Therefore, the expected Daily Wastewater Design Capacity is as follows: 1'Ria';cite S 1 q D' Ptiernintscli 1 1 1 1 1 1 1 Ili I 1418818` 1. 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1[ 1 1 4 Perc Test Hole Location tll1� Nis /i 4" SDR5� I I I I I I f l NOTE: 1 t 1 1 1 1 t t t 1 1 1 1 I I I I I 1 1 1 This layout and design is for con ruction based on actual percolation test ho x 1 1 1 1 1 1 1 4 locations. I). 1 1 1 1 1 1 1 1jt1 1 1 11 I I I 1 4 1 j� 2" HOPE \ 45' elbows) i Force Main Pipe to Leach Field 6" fire supply 71 pipeline 1 .4 I I I I J V I I I II`I V i i i 1 1 1 4 FCC �e rGc ( J __ TGC �—f rcc -n 9 Overhead Electric to be removed and replaced with underground line (Xcel Energy) 680 6" Isolation Valve Fence 2" Purecore fire tank fill line 3 10,000 gal buried fire tank 2" overflow line to daylight into drainage swale -- -569 Proposed 30' Drainage Easement Centered on Adjusted Property Line 15' Offset Each Side Toe Hydrant (typ), Existing irrigation system on hillside to be removed during earthwork construction activities. Church to reconstruct raw water irrigation system el Fire supply, stub to building, see architectural or fire suppression system design for details. TGC =53IPMC_—6"PaWC—Grp sl 0, forte rain Preschool Students (76) = 1140-gpd Preschool Staff (16) = 240-gpd Daily Wastewater Design Capacity = 1380-gpd Minimum recommended concrete septic tank size: 1.25 days (30 hrs) x 1380-gpd = 1725 -gallons (2000 -gallon septic tank) The septic tank size requirements will be met by one 2000 -gallon concrete tank. The tank will collect the wastewater the preschool facility. The septic tank will discharge by gravity to a concrete vault. Effluent from the vault will be pumped to the soil treatment area located to the northwest of the preschool building. The soil percolation rate was determined from percolation testing at the New Creation Church property at the spots indicted and will be used. The design soil percolation rate will be 34 -minutes per inch. Additional soil percolation testing at the location of the new soil treatment area will be confirmed by the design engineer during construction. Should the actual soil percolation rate vary significantly from the design percolation rate, the required soil treatment area size will be recalculated by Colorado River Engineering, Inc.. Design Percolation Rate: 34 min/inch Design Long Term Acceptance Rate (LTAR): 0.5 gal/sq.ft./day The required Soil Treatment Area (STA) for a gravel type leach area is calculated using the following formula: STA = Design Flow / LTAR Therefore, STA = 1380-gpd / 0.5 gal/sq.ft./day STA = 2760-sq.ft. OWTS regulations allow a maximum reduction of 30% of the required soil treatment area for a gravelless type design in a Trench configuration, (CDPHE Regulation 43, Table 10-3, Rev. 6/2013). The proposed system is a Trench configuration. Therefore, the required Soil Treatment Area = 2760 sq.ft. x 0.7 = 1932 sq.ft. AculA 1. 2oa` SF b#/) 4 Required number of standard Qln� nfiltt ato Units = 1932 sq.ft. / 1/7 sq.ft./unit = There shall be 8 Trenches with each beingieunits long for uniformity for a total of ye units for uniformity. 1$ 144 Minimum Horizontal Setbacks: Setback from Well 188 ft Setback from Existing System: 260 ft The above designed OWTS shall be installed to satisfy all minimum setbacks and design standards as described by Garfield County and Colorado State regulations and will be installed according to all manufacturers specifications and recommendations. If during construction the soil treatment area trenches are moved from the general location as shown, Colorado River Engineering, Inc. can be available to conduct site visits during construction to observe exposed soil types. New Creation Church of Glenwood Parcel44 212335100099 New Creation Church of Glenwood Parcel 44 212335200098 W( � t. 2" Pur€66Cr fire tank fill-' line and valve- 2 alvvv� J s • 30 i 0 15 30 �\ V 60 GRAPHIC SCALE IN FEET 2" Purecore water ;supply line and Z valve to preschool 2/N. ✓ WL NIL IL clew.' 2• I\_2" Purecore water supply line and valve from admin. building Fence "k;,5660 _ ._.-- _._ _ ._ Detention/Water Quality Pond 70 N 2" H / Force Main PipeDPEt - to Leach Field ?, C a 0 ?1. r These drawings have been prepared for the client identified on the design sheet titleblock. Unless these drawings bear a signed engineers seal, they may be used only at owners sole risk. \�\ \ Stare /Away© ..\ 'at 24 ro Fn w Q O ct c gal. concrete nk to dual It _ p Overhead Electric to be removed and replaced with underground line (Xcel Energy) —~sti FU FD Engineer's Seal 5648 F❑ FO A--- FD F❑ / X 5648 FD FO "AII Was, ions dpinPittiere- --- 5660' 5646 FO F13____ Fd — -7 s =Cans -64J, o w t5 Sited q 4 r 415/15 Drawing Set Drawing Revisions Original Drawing Preparation N Description By Date Approved Date By Date Drawn KTS/MM 01/2015 A Checked JAO [12/27/201 A Approved CM 33110/201 Client Approved CoLo !> 9 1YC ENGINEERING INCORPORATED PO Box 1301 Rifle, CO 81650 Tel 970-625-4933 CLIENT: New Creation Church c/o Pastor Mark Bintliff P.O. Box 1966 Glenwood Springs, Colorado 81601 SHEET TITLE: Wastewater Plan ROJECT: CRE # 1006 - NCC Preschool CRE FILE: M:\Land Projects R2\1006 - NCC Preschool \dwg\CRE-DESIGN.dwg SHEET NO 9 OF 14 Revision �0, "nee` e Y i\O\\\�\\\\\\\\\\\` 24" Removable Carbon Filter Vent to be located in irrigation valve box with cover (typ) See Detail At Right For Typical Manhole Installation 24" %owet 90t TYPICAL FOR CONSTRU IN FIELD OR YARD NEENAH MANHOLE FRAME AND COVE R-1780 OR APPROVED EQUAL WITH WORDS 'SANITARY SEWER' ON COVE SAID CONCRETE GROUT WITH MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI Inlet and Outlet Pipes to be Sealed with Waterproof Material (typ) Inlet Inverts shall be at least 3" Higher than the Outlet Invert 2000 Gallon Septic Tank (Divided) To Filter Alarm 8" Zabel Outlet Filter 2400 gpd, 1/16", w/alarm or equal. ita 3.5' Min Pipe To Septic Tank 4" SDR 35 Sewer, Typ. (Schedule 40 Under Roads) (min. Slope = 2%) Sep:ic Tank (Traffic Ra:ed if Installed in Roadway) Concrete Septic Tank Detail (not to scale) To Last Trench Et 10 Hole Conc. w/ Baffle. Bed on 6" Cl. Compact Base to 95% tripution Box ase Course ified Proctor. MH Ca rt on w/ rtedCoversu ed on Conc to locks. 1 1 read*" Pump ISsr 6ox 6416 P Ovrc. ears 1 6' min. (typ) Min 6' Spacing (Not Shown) fir 2" HDPE Pipe Install Po Inlet o Putt Corvto ;N Mvcsiwt c A L. PbOM TYPICAL FOR CONSTRUCTION IN TRAVELED WAY IS/N) M1/4•I'MY ;NN. "Alair.94v1S40 area Fr/1 r4.114AM *AY MsaVAIS41214WAW•CaSSI REPLACE ASPHALT TO GRADE AND SPECIFICATIONS OF ORIGINAL ASPHALT REPLACE BASE COARSE AND SUBBASE TO ORIGINAL SPECIFICATIONS To Pump Control Panel Located Outside of Vault 24" SAW CUT EDGE OF ASPHALT BASE COARSE 48" UB -BASE EDGE OF EXCAVATION ADJUST TO GRADE WITH REINFORCED CONCRETE LEVELING RINGS 2' MINIMUM AND 12 -MAXIMUM 4.50' Min 2" HDPE Pipe to Distribution Box Approx. 450'. 9 s High Alarm.. aln +n�NG— lair err LEADS -- OFF - Install Tracer Wire with HDPE Pipe to Distribution Box. 48"0 Riser Sections as needed, with exterior waterproof coating, (typ) 2" Ball Valve Joints to be sealed with "Rubberneck" or equal for water tight seal (typ). 2" Check Valve 48"0 Vault with exterior waterproof coating. (2) 40 gpm min each Effluent Pumps whwiela nue. To Distribution Box. 6" • Equalizer at ch Feeder Pipe. Si /I alp IFS t� �I • 6' min.— (tyO) These drawings have been prepared for the client identified on the design sheet titleblock. Unless these drawings bear a signed engineers seal, they may be used only at owners sole risk. Min 6' Spacing (Not Shown) talkAMID SI rTh Treatment Area Infiltrator Plan I (not to scale) Concrete Pump Station Detail (not to scale) 14' SOP E DIST. a (a 6' min. (typ) Min 6' Spacing (Not Shown) To Last Trench n Trug 0IIIG Trench Resurfacing Pay I_ mit In Open Field Asphat \A /\ /\ Acceptable Compacted Backfill Material E E 2 8'•00 2 Minimum Surfacing Select Pay Backfill Limit O.D. • 24"± 0.D. +12"± Min. * 0.D + 24"+ Max. Class 6 ---- ABC .. 0. Outside Diameter Bedding / //./2,\//, / 4" PVC SDR 35 provide tracer wire * For HDPE Pipe, Minimum Trench Width to be O.D. + 24" .%?%/:%/iY/i//i//>///> 1 + d = 27" & Larger mg 'RCP Only 7, Gravity Main Trench Detail (not to scale) Actual Invert Elevation of pipe leaving building unknown pending mechanical design. Preliminary detail pending Geotech review NN-- Original Grade 2.00' Min h - Select Backfill with excavated materials. Max 1' lifts. Compacted to 95% modified proctor density per Geotech approval 2" HDPE from Septic Tank Effluent Pump. provide tracer wire �, Wastewater HDPE Pipe Trench Detail U (not to scale) Double Clean -Outs w/Removable Caps on line from Preschool to Septic Tank. Bi -Directional Cleanouts may be substituted. 14t Sw At Serge e* Pipe To Septic Tank 4" SDR 35 Sewer, Typ. (Schedule 40 Under Roads) (min. Slope = 2%) n Cleanout Detail K' (not to scale) NOTES: 1) General a) Engineered system requires Engineer's approval on all constructed items. b) Contractor shall notify engineer of construction progress so that engineer may schedule inspections accordingly. 24 hr. minimum notice is required. c) No back fill will occur on constructed items prior to engineer's inspection and approval. d) Engineer shall be notified when soil treatment area is under excavation e) Contractor shall reclaim all disturbed areas to pre existing conditions. f) For areas where vegetation is disturbed, contractor shall reseed with NRCS approved seed mixture oras approved by owner. g) Grading shall be accomplished such that roof drains, foundation drains, area drains or cistern overflows shall not enter the septic tank or any part of the wastewater treatment system. h) Contractor is responsible for locating water lines, wastewater lines, irrigation lines and other utilities that may or may not be shown. 3) Soil Treatment Area a) Orientation can be adjusted to match ground contours as long as setbacks shown on plan view are met. b) Alternative configurations of number of rows and length can be constructed as long as setbacks are maintained, total area is not reduced, and proposed layout is provided to engineer for prior approval. c) The final cover over the trenches shall be graded to deflect run-off water away from the soil treatment area. 4) Distribution Box a) Contractor may use a single distribution box as shown on plan or multipie boxes may be used with sketch plan to be provided to engineer for prior approval. b) Location of distribution box(es) and pipeline route to each trench may be field adjusted. c) Distribution box(es) shall be constructed with the inlet invert at least 1 inch above the level of the outlet inverts. 5) Pipeline a) The contractor may use a 6" PVC alternate, minimum slope would be 1%. b) The pipeline alignment may be field adjusted to avoid existing infrastructure and utilities as long as minimum slope and 4.5' min bury depths are maintained. c) The sewer line shall have a minimum offset distance of 10 -feet from any water line. d) At water line crossings, the sewer shall either be 18" below the water line or encased 10 -feet each side in concrete or larger diameter pipe. Water line/sewer line separation encroachments must comply with CDPHE encasement requirements. e) Cleanouts per plumbing code. Double cleanout between buildings and septic tank may be removed if plumbing code allows use of interior building cleanout and access bends in the building sewer shall be limited to 45° ells or long sweep quarter bends. f) All plumbing fixtures, sewers, vents, and appurtenances shall comply with State and local plumbing codes. g) All pipe trenches shall be recompacted to 95% std density or as field approved by engineer. h) Sch. 40 PVC is required whenever the building sewer is located under a driveway. Alternatively, pipe to be bedded with material to be approved by engineer. 6) Septic Tank a) The distance from the outlet invert to the tank cover shall be at least 12 inches. b) Liquid depth shall be a min. of 30 inches and the max. depth shall not exceed the tank length or 60 inches, whichever is less. c) The volume of the first compartment shall hold no less than 1/2 of the required effective capacity. d) The transfer of liquid from the first compartment to the second shall be made at a liquid depth of at least 14 inches below the outlet invert but not in the sludge zone. e) No enclosed structure shall be constructed over the septic tank. f) Tanks shall be inspected annual and pumped every 5 -years, or as needed. 48" Concrete Casing w/ Lid Supported on Concrete Block Concrete Distribution Box Concrete Block as necessary 4' SDR 35 Sewer Pipe to Trenches 24"0 Manhole Frame & Cover fPP.K / 0 Distribution Box Detail (not to scale) 4"" OPE 4.50 Min VI /AEI% 4" PVC Inspection Ports (typ) at end of each row. Protect with Irrigation Valve Box, 4" Notch to be cut in Infiltrator and secured with screws. Finished Grade • 4 Age s Quifilt r Units, Trench configuration "\ Backfill with Excavated Soils (See Infiltrator installation instructions) Stub 4" SDR 35 Sewer Pipe into Infiltrator Unit and secure with screws. Install splash plate below inlet. 1/2.,\.//\/:v// ,</y//`//v„/ ivy/v/iy// / Actual elevations to be determined based on existing infrastructure and conditions encountered in the field. Engineer's Seal (\\41‹.// / / i, // // /\//\//\/ \i//k/./*„i�:\//\i,/\//'<' \//\ Scarify Excavated Leaching Surface (Keep Heavy Equipment Out of Excavated Area). Entire Leaching Bed Surface to be level Within 0.1 feet. Treatment Area Infiltrator Profile (not to scale) AI_ CoNSTacidert 005 #4 91 ` 3/15/15 Drawing Revisions Original Drawing Preparation No, A A A A Description By Date Approved Date By Date Drawn KTS/MM 01/2015 Checked JAO D2/2712015 Approved CM 13/102015 Client Approved CoLoaAoO i,Y Y JL R ENGINEERING INCORPORATED PO Box 1301 Rifle, CO 81650 Tel 970-6254933 CLIENT: New Creation Church c/o Pastor Mark Bintliff P.O. Box 1966 Glenwood Springs, Colorado 81601 SHEET TITLE: Wastewater Details PROJECr: CRE # 1006 - NCC Preschool CRE FILE: M:\Land Projects R2\1006 - NCC Preschool\dwg\CRE-DESIGN.dwg SHEET NO. OF 14 13 Revision /0