Loading...
HomeMy WebLinkAboutApplication - PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Offlce:970·945-8212 Fax: 97Q-384-3470 Inspection Line: 970·384·5003 Building Permit No. _JILL~-- Parcel No: -~2395-134-06-013 Locality: Aspen Glen Fig. 7, Lot H13-__ Job Address: _ ___.,0245 S_ad_d_leback_R_d. Carbondale Use of Building: ___ covered patio [screened in) __ _ Owner: Hemm, Art ------- Contractor: OM Neuman Construction -- Fees: Plan Check: $ 72.31 Septic: --------·-------- Bldg Permit: $ 111.25 Other Fees: ----- Total Fees: $ 183.56 ---- • -Q. \9:-() '6' Clerk: -j\U\j)~ Date: I I . 2 3 4 5 6 7 8 9 10 11 12 GARFIELD COUNTY BUJLDING PERMlT APPLICATION 108 8., Street, Suite 401 , Glenwood Springs, Co 81601 Ph one: 970-945-82 12/ Fax: 970-384 -3470 /Inspection Line: 970-384-5003 www.garfield-county.com Parcel No: (this information is avai lable at the assessors office 970-945-9134) Describe Wo rk : Class of Work: o Alteration Garage: Septic : o Attached o Detached o JSDS Driveway Pennit: Owners valuation of Work: $ NOTICE Al!1!l2!i!l:· This appHcatioo for a Building Permit must be signed by the Owner of the propeny, described above, or an authorized agent. lfthe signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Meal Arttu. A Building Permit cannot be issued without proof of legal and adequa te access to the propeny for purposes of inspections by the Bui lding Department. Other Permits. Multiple separate permits may be required : (l) State Electrical Permi~ {2) CoWlty lSOS Permit, (3) another permit required for use on the propeny identified abo\•e, e.g. State or Co unty Highway/ Road Access or a State Wa stewate r Discharge Permit . void Permit, A Building Pemut becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is sus pend ed or abandoned for a period of 180 days after commencement. CERTIFICA TIOS I hereby certify that I have read this Applicarioo and tha t the information contained above is b\Je and correct. I understand that the Building Oepa~tmen t accep ts the Application, along with the plans and specifications and other data submitted by me or on my behalf(submiuals). based upon my certification as to accuracy. Asswning completeness of the submittals and appro,·al oftltis Appli catiou, a Bwllling Pcrutit will be iss ued granting permission to me, as Owner, to construct the sb\Jcture(s) and facilities detailed on the submittals re\iewed by the Building Depanment. In consideration of the issuance of the, Building Permit, I agree that I and my agents wiU comply with provisions of any federal, state or local law ~gulating the worlc and the Garfield County Building Code, lSDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if th e location, cons tru ction or use of th e sb\Jcture(s ) and facility{ies), described above, are not in complian ce with CoWlty Regulation(s) or any other applicable law . I hereby grant permi ssion to the Building Depanment to enter th e property, described abov e, to inspect the work . l funher acknowledge that the issuance of the Building Pennit does not prevent the Building Official from: {I) requiring the correction of errors in the submiuals, if any, discovered after issuance; or (2) stopping consb\Jctio n or use of the stru cture(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law . Review of this Application, including submituls, and inspections of the work by the Building Depanment do not constitute an acceptance of responsibility or li abilil)• by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations reSt with me and my authorized agents, including without limitation my arcbiteet desi · er and/ or builder. I HEREBY ACKNOWL I H.A VE READ AND Ul\'DERSTAND TilE I'(OTJ CE & CERTJFICA TION ABO~_/ -Jb ""O 'tJ DAT E STAFF USE O NLY Specia l Condi tions : Adjusted Va luatio n: Pla n C hec k Fee: P erm it Fee: Man u ho me Fee: l\1 ise Fees: ~ &oo ~ 7Z -~ /II.Z-5 I SDS Fee: Tota l Fees: ,?'b {]~~1\ Ba la nce Due : f\\'C(§tt: I S DS No & Issued Da t e: --/9'3 . /20 2£ ..___ Set backs: OCC Group: Const Ty pe: I • Zoning: 3t:J1 zc;1 liP j?V't? BLDG DEPT: PLN'GDEP T: ~~T' ~p ~J_y A'~/£ AP PROVAL D TE APP ROVAL' DATE The following items are required by Garfield County for a final Inspection: 1) A final Electrical In spection from the Colorado State E lectrical Inspector. 2) Permanent address assigned by Garfield County Bui lding Department a nd posted at the structure and where read il y visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and fin ished walls , ready for stove and refrigerator ; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door . 5) Steps over three (3) risers, outs ide or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requ irements includ ing guardrails. 6) Outsi de grading completed so that water slopes away from the build in g; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating c ircumstances., i.e. weather. Under s uch circumstances A Certificate of Occupancy may be issued conditionally. 8) A fina l inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any fina l sign off by the Fire District, and/or State Agenc ies where appli cable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS T O BE PROCESSED AND ISSUED. OWNE R CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C .O . WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the bui lding identified in the Building Permit. DATE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date "Art~I~I:O'mm""'~---c~~-co-----Subdivision ~0,2:c45e,S:e!a;,d,;d"l''eba,c:ok.c, C"''"'"b'e<"!edecai,e ____ Lot/Biock 29C!/IC'I-,12;c0"0£_8 __________ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Cnfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Carport: Total Valuation Crawl Space Total Valuation Decks/ Patios Total Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation sq.Ft sq.ft sq.ft sq.ft X $74.68 0 sq.ft sq.ft X $41.00 sq. fiX $33.68 sq.ftX $18.00 sq.f1 X $12.00 sq.ft X $9.00 200 sq.ft X $24.00 sq.fl X $12.00 Commercial ,r X ,r X ,r X ,r X ,r X ,r X Aspen Glen DM Neuman Construction 0.00 0.00 0.00 0.00 4,800.00 0.00 4,800.00 PLAN REVIEW CHECKLIST A pplicant /l;e.f 1/t-M m Buil d ing / Engineered Foundation v(A Driveway Permit t-Jflr Surveyed Site Plan JJ(A Septic Permit and Setbacks · L._Gradeffopography 30% / Attach Residential Plan Review List /Minim. A 1' . Q . . __ um pp 1cation uestionnaue / Subdivision Plat Notes ~Fire Department Review .L Valuation Determination/Fees ~Red Line Plans/Stamps/Sticker ~ Attach Con ditions ~Application Signed d__Plan Reviewer To Sign Application L Parcel/Schedule No. J 40# Snowload Letter-Manf. Hms. ;JjA Soils Report GENERAL NOTES: Da te __ 9-..t..~.....,1rzt...;;_~..::..o ____ _ P la n ning/Zon in g / Pr operty Line Setbacks ~Oft Stream Setbacks __ /_.F Flood Plain J Building Height L Zoning Sign-off !'fA Road Impact Fees _/_HOAIDRC Approval V Grade/Topography 40% Planning Issues Subdivision Plat Notes -- GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. \\Then reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the follo\\ing checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. I Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, v.indows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by munber and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously swveyed building envelope on a subdivision fmal plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the fmal plat with the proposed structure located within the envelope. ' Yes rJ(V'< 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes __ 'Pf 3. Docs the site plan include when applicable the location of the LS.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes f1jA 4. Docs the site plan indicate the location and direction of the County or private road accessing the property? ) !1>.. Yes. _____ 1 r 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to usc a private easement/right of way; A-County Road and Bridge pennit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a pennit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agenciys ~ Yes_-'-'\/"---W" 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes fJI\- 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No -;If' 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes, _____ _ No __ rJf' 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 polUlds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes 1J (f' 10. Does the plan include a building section drawing indicating fooodation, wall, floor, and roof construction? Yes rJ [~ 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roofra:ftcrs or joists or trusses? Yes rJ~ 12. Does the building section drawing or other detail include the method of positive connection of all columns and beams? ;J v._ Yes 1 I"'- 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes ~{*- 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No tJft 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes. ____ No. ____ tJ~ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes rJ.f\- 17. Docs the plan include a window schedule or other verification that windows provide natural light and ventilation for aU habitable rooms? Yes }J~ 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? II) n Yes No ________ j-fl 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Jl Yes·-------l~]" 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, arl\. building plans in compliance with all plat notes and/or covenants? Yes. ______ i'f'- 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes ).L- 22. Will this be the only residential structure on the parcel? v. f ]A Yes No Ifno-Explain:l_i7_ "----- 23. Have two(2)...complete sets of construction drawings been submitted with the application? , Yes.~,!-)<-__-"'--- 24. Do you unzstand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes · 4 25. Have you designed or had this plan designed while considering building and other construction code requiret(l-91ts? Yes'~L.A-'-"'~~- 26. Do your plans comply with aU zoning rules and regulations in the County related to your properties zone distr!Pt? Yes~,./-'-"--~~- 27. Does the plan accurately indicate what you intend to construct and what will receive a fmal inspection by the G'!f(ield County Building Department? Yes~~)(_'-"~~- 28. Do you understand that approval for design and/or construction changes are required prior to the applicatiqn of these changes? Yes )<., 29. Do you understand that the Building Department will collect a 11 Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road)IJ1pact11 or "Septic System" fees required, at the time you pick up your building permit? Yes,_£.)C-.--=-~-- 30~ Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-<i_003. Yes .)\ No~----- 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes X 7'- 32. Are you aware that you arc required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the build~g\1 Y es,_,./?L'"-~~~- 33. Are you aware that the Pennit Application must be signed by the Owner or a written authority being given '(oy an Agent and that the party responsible for the project must comply with the IRC? Yes,~A;:....> ___ _ 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable'1irnspection. . Yes ~ ~~~------------ 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes tJfc 36. Do you know that the local fire district may require you to submit p lans for their review of fire safety issues? Yes -------JtJtldJlflf---(please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to iss.x:_e of a building permit that you will be required to obtain a grading permit? Yes · 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a $:~ificate of Oc;rcy? !_hereby acknowledge that I have read , understand and answered these questions to the best of my ability. Signa Phone: q~ s-) 5 DL (days); Project Name: ±\-e,vnvl\ ~l ~v'u-e_, Date ------------------<evenings) Project Address: DL..-'-l S ":>~ h-u.-\ (___ ~~ b{d\ ) 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building peimits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 JRC, IBC, IFGC, IMC, !PC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. Seismic design category: B 75PSF 8001 to 9000ft. IOOPSF 9001 to lOOOOft. \\1eathering probability for concrete: Severe Termite infestation probability: None to slight \Vind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to SOOOft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under~layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Valucs: • • • Ceilings/roofs R values are: R-30 stick built structures. R-38log construction and steel rafter construction. Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. Floors R-values are R-19 . • • • Basement wall R-values are R-10 befow grade, R-19 above grade. Slab perimeter R-value and depth is R- 10/36in. Crawl space wall R-values are R-IO below grade and R-19 above grade Jf floors over crawl spaces are not insulated, the crawl space walls must be insulated. Bac;ement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulatibn. Common ceilinglfloor garage to house must have R-19. Take precautions to protect plumbing in these areas. NEUMAN CONSTRUCTION CO. [970) 945-7502 31 0 1 9th Street, P.O. Box 2317 Glenwood Springs. Colorado 81602 As owner of the below referenced prop er ty, I authorize DM Neu man Construction Co., to sign and subm it for a building permit for use at 0 2.<{ 5 ScteJcl/e bv.<..-k j -1 u -o6 Date 11116 No. ---------------------Assessor's Parcel No. 2395-134-06-013 Date ___ 91_1_91_20_0_8 __ BUILDING PERMIT CARD Job Address ____ ...:0:::2::4:.::5...:S::a:.:d:.:d::le::b::a::c::k:..:r:.:d::,:.:C:.:a:.:.rb::.o::.n:.:.d::.a::l::.e--->:(A:..:s::cprce:::n.:....::G:.:.Ie:::n.:..:.:fl"g'-7 •c:L::.o::.:t:..:H..:.1:.:3:..:0:.__ ____________________ _ Owner ________ __:H..:.e:.:m=m.:.:.•..:.A.::.rt.:__ _____________ Address ___ 0_24_5_s_a_dd_l_eb_a ..... c_k_rd.:.., ..... c_·d_al_e __ Phone # 963-1797 Contractor DM Neuman Cons! Address Box 2317, GWS Phone # 945-7502 Setbacks: Front __________ Rear----------RH _________ LH __________ Zoning ________ __ covered patis (screend in) Soils Test -:-:-:::--:-===------------- Footing ;o-a...::;~ Foundation ____________ -7-----;------ Grout _____ ~-------T---~L------ Underground Plumbin\V-----,L-------- Rough Plumbing __ .<..,-__ _,:.__ ________ _ Framing f(l-~9-<:?&-~ Insulation -----f'-----f'----------- Roofi ng ------f'------f'------------ Drywall -----f'-.----:t'------------- Gas Piping r-----.....J..--------------- INSPECTIONS Weatherproofing ------,L/ ______________ _ Mechanical Z Electrical Rough (Stale) _____.- Electrical Final (State)~~~;;~~~~~~; ~inal 1<>-J94 /Checklist Completed? Certificate Occupancy # -------------- Date~~===;~================= Septic System #. Date ------,t.=------------------ Finai __ ~L------------------ Other ________ _,L..-------------------- NOTES (continue on back) BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION Wll.l NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is grant~. and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the U•e coven:x:!Co~~~COMENULLANDVOID. Add,.,o,Leg•IDm,lptlon ~'__SGtdd!eba£t. gQ, C•dctlf, own" l-\eMM 1 Arr cont"''o' 'OU NeUMfAll Coos+~ Building Pe•mltType 'Rfsiaentldl This Card Must Be Posted So It Is Plainly Visible From The Street Unlil Final Inspection INSPECTION RECORD Footing Driveway /r:-~ -;':'R 'f#'/,x;;!. \ Foundation I Grouting I Insulation --~ J'.!l Underground Plumbing I Drywall ~r' ........ f Ele<t•k Fln•l (by Stole ln•pe<tm) ~ Rough Me<h•o.l<•l IV --(Prior to final I Septic Final \. Gas Piping I FINAL f0-;2.?-og;--'f'?~A.-x Electric Rot (by State !nspe~,;tor) (You Must Call For Finallnsp..cli<>nl (Prior I<> Framing) Notes Framing Ito includo Roo/In place & Windows & Doors installed & Firestoppin11 in place) ---------·-- THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970-384·5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 APPROVED (\lq-1\.J' DONOTDESTROYTHISCAR?If Dote ____ 'r \Ill By~V\ .• la1kf""" __ PROTECT PERMIT FROM WEATHER MAGE (DO NOT LAMINATE) Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Pro.Qer_ty_S_~a_rcb I Assessor Subset Query I Assessor Sales Seare:h Clerk & E.ecm:d.Gr . .RGc_cption Search B<!.slc_B~Uding Characteristics I TaxJnfo_nnation Parcel Detail I VaclJle Detail_ I Sales Detail I Reside_miaii_Cpmmercial Im~rovement_ Detail Land Detail I Photographs I Mill Levy_Re~enues Detail I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 082 II R005447 II 239513406013 II 64.976 I ------·------- Owner Name and Mailing Address IHEMM, ARTI!UR R & CATHERINE E j245 SADDLEBACK RD jCARBONDALE, CO 81623 Assessor's Parcel Description (Not to be used as a legal description) lsECT,TWN,RNG:l3-7-89 SUB:ASPEN GLEN IFLG #7 LOT:Hl3 PRE:Rl 00091 BK:l931 IPG:0690 RECPT:724375 BK:l643 PG:852 IRECPT:664269 BK: 1643 PG:830 IRECPT:664267 BK: 1634 PG:829 IRECPT:664266 BK:l220 PG:l42 IRECPT:572987 BK:0921 PG:0661 IBK:0921 PG:0661 BK:0918 PG:0408 IBK:0911 PG:0791 BK:0908 PG:0449 IBK:0908 PG:0447 BK:0908 PG:0445 IBK:0908 PG:0443 BK:0908 PG:0441 IBK:0908 PG:0439 BK:0894 PG:0995 IBK:0894 PG:0702 Location http://www.garcoact.com/assessor/Parccl.asp?AccountNumber==R005447 I I I I I I I I I I I I I 9/10/2008 Parcel Detail Page 2 of 4 Address: 11245 SADDLEBACK RD )A If I Subdivision: II 'p"" GLEN FLG #7 I ~SqFt: 110607 I llo I ~ ~ I 13 7 I 2008 Property Tax Valuation Information II II Actual Value II Assessed Value I I Land: II I4o,oooll 11,1401 I Improvements: II 704,54oll 56,0801 I Total: II 844,54oll 67,2201 Additional Val_IJ.J< Detail Most Recent Sale Sale Date: 115/25/2007 Sale Price: Ill, 117,500 A_dditional Sales O~t<!il Basic Building Characteristics Number of Residential I Buildings: Number ofComm!Ind 0 Buildings: Residential Building Occurrence 1 Characteristics 2 STORY: 111,207 1 STORY: 1777 TOTAL HEATED AREA: 113,191 ABSTRACT CODE: IISINGLE F AM RES- IMPROVEMTS I ARCHITECTURAL STYLE: 112-STORY I I EXTERIOR wALL: IIWD SIDING I I EXTERIOR WALL: II STONE YEN I I ROOF COVER: llcOMP SHNGL I http://www .garcoact.com/assessor/Parcel.asp? AccountNumber=R00544 7 9/10/2008 Parcel Detail Page 3 of4 ROOF STRUCTURE: II RIDGE FRME INTERIOR wALL: IIDECORA TIVE INTERIOR WALL: IIDRYWALL FLOOR: IICARPET FLOOR: IIHARDWOOD FLOOR: IIHARD TILE HEATING FUEL: IlGAS I I HEATING TYPE: IIFORCED AIR I I STORIES: llsTORJES 2.0 I I BATHS: I 3.5 I ROOMS: 16 I UNITS: II I BEDROOMS: 13 I YEAR BUILT: 112003 I Additional Resjd~ntial/Commercial lmproyement Detail Tax Information Tax Year II Transaction T~l!e Amount I 2007 II Tax Payment: Whole ($4,367.68)1 2007 Tax Amount $4,367.681 2006 Tax Payment: Second Half ($2,225.46)1 I 2006 Tax Payment: First Half II ($2,225.46)1 I 2006 Tax Amount II $4,450.921 I 2005 Tax Payment: Second Half ($2,235.22)1 I 2005 Tax Payment: First Half ($2,235.22)1 I 2005 Tax Amount $4,470.441 I 2004 Tax Payment: Second Half ($2,427.81)1 2004 Tax Pa~rnent: First Half II ($2,427.81)1 2004 Tax Amount II $4,855.621 2003 Tax Pa~rnent: Whole II ($4, 131.46)1 2003 Tax Amount II $4,131.461 I 2002 Tax Payment: Whole ($2,720.80) 2002 Tax Amount $2,720.80 2001 Fee Payment II ($30.25)1 2001 Interest Pa~ment II ($73.63)1 2001 Interest Charge II $73.631 2001 Tax Payment: Second Half II ($1,227.18)1 http://www.garcoact.cornlassessor/Parcel.asp?AccountNumber=R005447 9/10/2008 Parcel Detail Pagc4of4 2001 II Fcc Charge II $30.251 2001 II Tax Payment: First Half II ($1,227.18)1 2001 II Tax Amount $2,454.361 2000 II Tax Payment: Second Ilalf ($1 ,667.22)1 2000 II Tax Payment: First Half ($1,667.22)1 I 2000 II ·raxAmount $3,334.441 I 1999 II Tax Payment: Whole ($222.40)1 I 1999 II Tax Amount I $222.401 Mill Levy Revenues Detail .. --------------·-··· .... ----------------------·------------------------------- LQn ofPag~ Assessor Databas~-s~~rch Options 1 Treasurer D_atab<!_se . .S~arc_h_Qlltions Clerk & Recorder Database Search Options Garfield County Home Page ---------------------- The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices arc unable to warrant any of the information herein contained. Copyright© 2005-2008 Good Turns Software. All Rights Reserved. Database & Web Design by Good Turns Software. http://www.garcoact.com/assessor/ParceLasp? AccountNumbcr=R00544 7 9/10/2008 -APPROVE-6------------~ I Sl!B.JECT TO N()T[:IJ. EXCEPTIONS & IN..WEcnONS GARFIELD COUNTY BUIL~DEP~T Date 9-N i!' Ry LDC PY NO n!SPI<:CTI0:-1 WITHOUT T.BESE VLANS. ON Sll'E ~ ~!" ::.~~ '"' ~;;.;,..,, ,.._~~ I .. @ ~---, .. ® L __ ' ! Shed Roof ------- I~, .. _,_ jooooool Pergola Elevation ,._