Loading...
HomeMy WebLinkAboutOWTS System Design 04.12.201615032_V-Topo.dwg 4/12/20161.10 PM T.B.D. Huebinger Drive \ Lot 51: Westbank Ranch PUD, Filing IV \ County of Garfield, \ i State of Colorado Parcel No: 2392-022-06-051 r / .,` 0 / / 0 .0' r / r ,.- '"- .✓ rte' ,.-" ,r e O ./' r r r ,/' s r '� .0 f 0 ✓ r � �/ .'^ .-' r' f . / ../ r / .0 0 % r r r 0- „,/'^, / '`' O •°.- /0' p•,. i' r '"' 0." "' .0....... / �. .^' „ .^' 0'.° ..616`'"• O - .'-' / -' ..' l,,,r 1 /` .-• -' ,r �f w-" ,r '`� / / 4'0 SCH.40 PVC TO THE TANK l r// e J e ' ✓ r .- BCLEANOUT ATTHE BUILDING '� N.y' - / ® �' r --- r r CDPHE APPROVED 2,000 -GALLON -- ^fir• .'- s ^✓ / PRECAST CONCRETE TWO CHAMBER , / N. `�. / t SEPTIC TANK WITH SCREENED DOSING \ \ 1 ' - O PUMP PACKAGE (SEE DETAIL) / p r r r J N. N. `N. \ � - -- � \ \ \ N. N. \- \ r • N. N. N. N. \ . N. � \N. \ �" N. t N. ........ - \ N. \ `\ \ N. � �, N. \ ` N. \ \ \ y.. � \ \ FLUSH VALVE, TVP... \ . N. it N. ` N. N. N.N. ` N. N \ N.'N.` N. N, \ INSPECTION N. \ \ \ \ N. \ \ PORT, TYP. N. N. \ \ N. N. \ N. \.� N. \ INSTALL SEDIMENT CONTROL FENCING ALONG THE LOWER LIMITS „r OF ALL DISTURBANCES, TYP. N. N. �� N. N. N...___. N. \ N. N. `-- N. \\ ' N, \ -- \N. \ '\ N. N. \ \ N. \ \ --NN SITE EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DANIEL E. HARDIN, PE H.P. GEOTECHNIC4I, INC. 5020 C.R. #154 GLENWOOD SPRINGS, CO 81601 970.945.7988 2. EVALUATION DATE(S):JANUARY 15, 2016. 3. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF= 600 GPD: 3.A. SPRING OR WELL=100' 3.6. POTABLE WATER SUPPLY LINE= 25' 3.C. POTABLE WATER SUPPLY CISTERN= 25' 3.D. DWELLING =20' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 3.G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H. DRY GULCH, CUT BANK OR FILL AREA=25' 3.1. SEPTIC TANK=5' 3.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 3' (TREATMENT LEVEL 1, PRESSURE DOSING) 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A. SPRING OR WELL= 50' 3.B. POTABLE WATER SUPPLY LINE=10' 3.C. POTABLE WATER SUPPLY CISTERN= 25' 3.D. DWELLING=5' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.E. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND =50' 3.H. DRY GULCH, CUT BANK OR FILL AREA=10' 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' 100 QUICK -4 UNITS (4x25) OR 64 ADS BIODIFFUSER UNITS (4x1 N. \ \ -- N. \ \ \ N. \ \ \ \ • \ N. N. \ \ e N. \ IN. \ \ \ N. N. N. � � \\ \\ \ `'` N. L"6 SURFACE aY l 8'B"- _...... _ CLAY - (CL) SILTY, - SLIGHTLY '- - SANDY - W TO SANDY, - SLIGHTLY MOIST, HARD - BROWN, _ :CALCAREOUS - (TYPE -3) - 1-1/2"0 SCH.80 PVC DISTRIBUTION LINE r PROPOSED RESIDENCE _-6110 i N. \ \ \ ---.......420 \ N. \ \ � N. ` \ \ N. \ \ \ \ \ \ \ N. \ ▪ \ N. \ \ \ N. \N, Site & Soils Evaluation Scale: N.T.S. IRRIG. VALVE BOX 1"0 BALL VALVE THREATdASSEMBLY 1"X-1/2" PVC REDUCER 1-1/2"0 PVC ELBOW 0 Flush Valve 1-1/2"0 PVC DISTRIBUTION PIPE ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. 4' PVC WYE �• 4"045°BEND II�II� FINISH GRADE 4°0 PVC RISER 4"0 SEWER LINE \ Cleanout Scale: N.T.S. N, ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. 4"0 PVC SOLID PIPE CUT TO FIT GENERAL ABSORPTION AREA NOTES INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION BEDS SHALL NOT EXCEED 12' WIDE BY 100 -FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR PATTERN WHENEVER POSSIBLE. 3. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN IXPENSE. 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE D(CAVATION. 7. TOPSOIL COVER MAY BE VARIED (1 -FOOT MINIMUM, 2 -FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. m\ \ r COVER WITH 6" OF TOPSOIL AND REVEGETATE 4'0 COUPLING (UNION). USE A HOLE SAW TO CUT OUT CIRCLE OFF THE CENTER OF THE UNIT i 4°0 PERFORATED PVC PIPE. " EXTEND PIPE TO REST ON V.,.*�� ��y /\ , BOTTOM OF THE BED y/�.��: %��� /, n Pressure Dosing Chamber Bed ei N 1 S GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. 1-1/2°0 SCH. 40 PVC �\ PRESSURE DOSING PIPE WITH 3/16"0 HOLES EVERY i 48"0.C. (FACING UP) r%y� j PREFABRICATED PIPE SUPPORT OR MANUFACTURER SUPPLIED HANGING SYSTEM (PIPE @ 6" MIN. ABOVE BASE). 1 1 \ \ \ \ Vicinity Map 1"=2000 to Carbondale SYSTEM NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION #43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE ENGINEER MUST OBSERVE THE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE A LEI IER OF INSPECTION AS REQUIRED BY THE LOCAL AGENCY. A REQUEST FOR INSPECTION MUST BE MADE BY THE CONTRACTOR AT LEAST 48 -HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING. 2. DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A. FIVE (5) BEDROOM RESIDENCE USING DOSING AND TREATMENT LEVEL 1 (TL1). 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD 5): 2.6.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BODS lbs/day 2.B.2. ADWF = 75 gpd(3 BEDROOMS ` 2 PERSONS/BEDROOM +1 BEDROOM ` 1 PERSON/BEDROOM) =600 gpd 2.8.3. BODS = 0.201bs/day ` (3 BEDROOMS " 2 PERSONS/BEDROOM + 2 BEDROOM ` 1 PERSON/BEDROOM)=1.60lbs/day BODS mg/L = BODs"1,000,000 = 1.601bs/day`1,000,000 = 319 mg/L ADWF"8.34 600 gpd`8.34 2.B.4. CBOD5 = BOD5' 0.85 = 271 mg/L 3. SEPTIC TANK (SEC.43.9.8.2.a): 3.A. SEPTIC TANK: 5 BEDROOMS = 1,250 GALLONS (4 BEDROOMS) + 1 ADDITIONAL BEDROOM ` 250 GALLONS = 1500 GALLONS. 3.B. DOSING SHALL REQUIRE THE USE OF A 2,000 -GALLON TWO-COMPARTMENT TANK OR A 1,500 -GALLON TWO-COMPARTMENT TANK IN SERIES WITH A 500 -GALLON SINGLE COMPARTMENT TANK EQUIPPED WITH A DOSING PUMP STATION. 3.C. THE TANK IS NOT SUBJECT TO BUOYANCY. 4. ABSORPTION AREA CALCULATIONS 4.A. GROUNDWATER WAS NOT ENCOUNTERED, THE OWTS SITE CONTAINS SLOPES LESS THAN 20%, BUT THE OWTS SITE IS UPHILL OF THE LOWER LEVEL OF THE BUILDING. THEREFORE, THE SYSTEM SHALL BE A PRESSURE DOSED SHALLOW GRAVELLESS CHAMBER SYSTEM IN A BED CONFIGURATION. SOILS WERE ANALYZED BY HEPWORTH-PAWLAK GEOTECHNICAL, INC. (JANUARY 15, 2016; PROJECT NO.115 591A) TO BE CLAY (CL) SILTY, SLIGHTLY SANDY TO SANDY, SLIGHTLY MOIST, HARD BROWN, CALCAREOUS (TYPE -3) WITH A PERCOLATION RATE BETWEEN 7-10 MPI AND A RECOMMENDATION TO OVERSIZE THE SYSTEM DUE TO THE CLAYEY SOILS AND POSSIBILITY OF A SLOWER ACTUAL PERCOLATION RATE THAN WHAT WAS TESTED. THEREFORE, THE SYSTEM HAS BEEN DESIGN WITH A TREATMENT LEVEL 1 LONG TERM ACCEPTANCE RATE (LTAR) OF 0.35 gpd/SF. 4.B. MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 600 =1714.3 S.F. LTAR 0.35 gpd/S.F. 4.C. SIZE ADJUSTMENT FACTORS: PRESSURE DOSING =1.0; CHAMBER BED = 0.7 4.C.1. A, adj = 1714.3 SF " 0.7 = 1200 SF 4.D. GRAVELLESS CHAMBER SYSTEM: 4.D.1. INFILTRATOR QUICK4:1200 SF / 12 SF/UNIT = 100 UNITS IN BED CONFIGURATION. 4.D.2. ADS BIODIFFUSER (STANDARD): 1200 SF / 18.75 SF/UNIT = 64 UNITS IN A BED CONFIGURATION. 5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITES OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100 -FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3 -INCHES OF BLUEBOARD INSULATION, 3 -FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5 -FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2 -FEET. 10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. Effluent Pumping System - 2nd Compartment Drawdown Fiberglass Gasketed Lid with Stainless Steel Bolts Slope Ground Away from Riser PVC Riser with Grommet(s) Inlet Tee Patents # 4,439,323 & 5,492,635 Foreign Patents May Apply p 2006, Orenco Systems, Inc. Control Panel To Control Panel 2,000 Gallon Two -Compartment Concrete Tank (Comp. 11=1,500 Gal. Min.) Conduit Seal z z Top View (NTS) Simplex Pumping System PVC Splice Box w/Cord Grips Fiberglass Gasketed Lid with Stainless Steel Bolts PVC Riser with Grommet(s) Discharge Assembly 814 AIRWAY AVENUE SUTHERLIN, OREGON 97479-9012 TOLL FREE: (800) 348-9843 TELEPHONE: (541) 459-4449 FACSIMILE: (541) 459-2884 NDW-TD-EPS-03 Flexible Hose Rev. 3.0 (03/06) Effluent Discharge Tank Adapter (Cast or Bolted) NOTES: 1. THE EXISTING TANK SYSTEM IS TO BE REMOVED AND DISPOSED. 2. FLOATS SHALL BE SET FOR A DOSING VOLUME OF 200 GALLONS (3 DOSES PER DAY). 3. SYSTEM TO BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. 4. THE DISCHARGE PUMP SHALL BE A HIGH HEAD VERTICAL TURBINE PUMP. PUMP RATE AND MODEL TO BE SPECIFIED BY THE MANUFACTURER. CONTACT SCG ENTERPRISES AT 303.697.9404 OR VALLEY PRECAST, INC. AT 719.395.6764 FOR SYSTEM SPECIFICATIONS AND INSTALLATION PROCEDURES. 5. THE PUMP SYSTEMS SHALL BE CONNECTED TO AN ALARM WHICH SHALL BE BOTH AUDIBLE AND VISIBLE, LOCATED WITHIN THE RESIDENCE AND ON A CIRCUIT SEPARATE FROM THE PUMP. 6. THE SYSTEM SUPPLIER SHALL PROVIDE THE OWNER WITH AN OPERATIONS AND MAINTENANCE MANUAL WHICH INCLUDES A MAINTENANCE SCHEDULE. 7. TANK DIMENSIONS ARE BASED ON A VALLEY PRECAST, INC. 2,000 GALLON TWO-COMPARTMENT TANK WITH A HIGH HEAD PUMP. CSeptic Tank & Dosing System T Flow Inducer Level Control Float Assembly Filter Cartridge Vault Inlet Pods Orenco Effluent Pump BietubPPump Vault Bo Civil Engineering dSurveying & Beyond coItaG `O%t e d jnc. 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal ,„„,, -N N Llc .."-_0„0O q\1 1111 es ON'. �G SON W'41F/P� 111 i V CoQ 4/12/16 y � i c 37110 i i9'-�-. .,c tile .fr r.m=o.s weri hticc; 1,11 \�iNk -. ---- iovn , = ,3, ��� Client Information: BRIAN DERKASH 724 SAN JUAN DRIVE LAFAYETTE, CO 80026 970.230.1048 NORTH sim 20' 40 " = 20' Know what's below. Call before you dig. I lift,C \ ; wefts ai In O CC � O z y y O CI3 C1 V Z etcu i` O 1..., V W � MC cb CZ *IS CO co3 w 1�1A y L %ad CD O m 0 z- N (h V Lei co r--, N m PRO32JECT NO. 150 Sheet FILE NAME: 15032_v-topo.tlwg H ner: Jvu9 . w 1 I L sinner: Date 4/12/16