HomeMy WebLinkAboutPlansCHANGES IN TEMPORARY CONSTRUCTION TRAILER PLACEMENT Please note that the placement of the construction trailers has been modified from the original plat provided with the Special Use Permit Application. These changes are being implemented to improve safety and operations in the Central Production Area storage area. The revised placement also optimizes space requirements to allow additional room for general storage. Sheet No. 1 =========;;;:==:.==== =======:=======================================: BEN J. KRAKOWSKI, P. E. CONSULTING STRUCTURAL ENGINEER •·. • ••• ,.,. r • ~ : ... : ... t • 13413 N . 101st Way Scottsda.Je: · Az . 85266 Phone : (480) 451 -0587 ================= ============================================== C~_L_9_lL~_JJQNS FQA : STD. 12' x 60' MODULAR OFFICE UNIT STATE OF COLORADO PREPARED FOR : MOBILE MINI, INC., MARICOPA, AZ. 2003 · International Building Code Roof Uve Load Roof Dead Load Floor Uve Load Floor Dead Load Wall Dead Load Wind Load :~ = = = = = 40 psf (snow) 10 psf 50 psf 10 pst 7 psf Basic ·wind Speed, v 3s = 100 mph, lw = 1.0 Height & Exfi>osure Coeff. (0 -15', Exp. C) = ·1.21 MWFRS Load = 15 .9 psf (roof slope: 0-5 deg.) p = (15.9 psf)(1 .21)(1 .0) = 19.2 psf (horiz.) Seismic Load : S"ffe cras-s-·-D~ Design Category D Ss <= 0 .25, Fa = 1.6, le = 1.0, A = 6.5 S ms = Fa Ss = (1 .6)(0 .25) = 0.40 s ds = 2/3 S ms = (2/3)(0.40) = 0 .267 V (simplified) = 1.2 S ds W 1 A = 0.092 W Allowable Soil Bearing Pressure = 1,000 psf MATERIAL .§.P~CI FICA TI()N_§_;_ 1. Foundation Pads -3 " thick precast concrete or min. 3/4" thick pressure-treated plywood * (marked PS 1 ). See Foundation Plan for pad sizes. 2 . Support Piers -Adjustable steel jack stands, min. 4,000 lbs . capacity. 3. Tie -Down Anchors -Minute Man Model 4430 -0H 3/4 MMA -6 (or equal) auger -type anchors , min . holding power = 4,725 lbs . lnst~l per waoutacturer's recommendations. ------~----------------------------~ s . Szs.-- * P-T Plywood pads: min . 3/4" thick for 16" x 16"; min. 1 1/8" thick for 24" x 24". 12' x 60' UNIT: Sheet No. 1,. ========================================================-==-- FOUNDATION PADS ============~===================================;============= QESIGN J2AJA : Roof LL + DL = 50 pst Floor LL + DL = 60 psf Exterior Wall DL = 7 psf Allow. Bearing Pressure = 1 ,000 psf E8QS. ALONG_ CHASSIS .BEAM SUPPORTS : Spacing of Pads = Total LL + DL = Pad Area Req'd. = Area Provided = 2.50 ft. o.c. 1,767 lbs. 1.77 sq. ft. 1.78 sq. ft ...... OK Roof Trib. Width = Floor Trib. Width = Ext. Wall Height = Type of Pad: Pad Width = Pad Length = 5.9167 ft. 5.9167 ft. 6.00 ft. See Sheet No. 1 16.00 in. 16.00 in. Therefore, Use: J6" x 16" Fqundation Pad!J _ _@_2'-6" o.c. (::>~ Sf:!~~!_ No. 1), f!elow Mi!JSt~l~ ~t~~:~tJack_ §lJPPc>rts. !,t.TEAAL FORQE ANCHORAGE: Wind Load = 19.2 pst Seismic Load = 0.092 W Max. Wind Load= 3,091 lbs. <--Governs Max. Seism. Load = 449 lbs. Anchor Type: MMA-6 Auger-Type Anchor Capacity > Max. Load .... OK Roof + Floor DL = Building Width = Building Height = Anchor Spacing = Anchor Capacity = 20 pst 11.63 ft. 11.50 ft. 14.00 ft. o.c. 3,340 lbs.* Therefore, Use: MlniJ!e. Man Mg_~~--4-t3Q-:-PH ~~~-.tJI~=~-J\L!ger:::!~e Anchors {Or Eguai) __ @_J£:-0" o.c.L~=-~~h Side ofJ.Jnjt. *Anchor capacity @ 45 deg. angle = (4,725 lbs.)(0.707) = 3,340 lbs. ~~--" .ftt· ~v. "R:!~ . . ··"-:,. " ''oo'·.:;,, I ~·:<> ;',"!;. (/)~ ji¥1: 24600 25 } r/t}·. / '• ........ .·· ~ ,.-;r_, ·-....... •' :... ...... ft. ~~~... -·<f>\.{• IT lt- 60' l • 1 14'-0" r 14'-0" I I t- 1 14'-0" I Sheet No. 3 CONSUl. Tlf.J'G-STRDCTURAL l:f\.IGINEER ----------·---~~.-----------. -------~-----·---·--· --~~-- 11 '-10" 7.958' . (95.5'') l4--C.L steel chassis beam-~ FOUNDATION PLAI':{ .,~~-(N.T.S.) 11'-0" ---- 2'-6" o.c. i 16" x 16" Foundation pads with adjustable steel support pier, typ. See Sht. No. 1 for specifications ..,_ Unit outline .--+--Auger-type tie-down earth anchors (10}, see Sheet No. 1 for specifications. STANDARD FACTORY-BUILT MODULAR BUILDINGS !>iHl-4\A.S~I$ E'>EN1-~ ~J . .STE.E.L. \'lf.{l. fovtJI>A1\-v..V PA.-111 SE.E. PLktJ ---, Q)'IIP· foutJ[)A.TloN 'PA:D ly Pl£F- lSA.HMJi,..lT FfZAME.) ' II£--bot.J.V f. A P-1\-\ 1\fJt:-\\ol!..; Sf:. f. PLAt-> ----;J..----;;;(-...-.ll~ TYPICAL FOUNDATION & TIE-DOWN DETAILS Scale: 3/4" = 1'-0" S-1 FINISH SCHEDULE FLOOR BASE WAllS TRIM CEIUNG SYM S THK. "'-'~'L TYPE MAn lYPE JAMB GRP GR QTY OPENING REMARKS ® 3018 1 3/4" ~-H.U. NJM 4 1/• :s1 1/2." • Ill 1/4 SYM 61 311" .~· FINISH GROUP REMARKS IIORI20N'IAI. ..wt.IINUM ..... 8I..M>S {"""") (>) COLOR>r""' lifT. I'IINODW GIJAIICS •/ ONE W~V SECUim' SCR(WS OR, el.'!:K OETAI APPHOVEu SUB.ll'XT TO N()11tD .t.XuxnoNS a INSI"t.~ GARf'~H•:LD COUNT\' OOILDlNG DICPI\R;I:.lMf."'' ~...,._M: ffiD ~~ By .J.\.. .. ,) i'lELU c:y;>y i\'!0 f'>-t":"o?Ecn..::·:( ·_·-~~~,~ : ~(~ fL'"IH<:. :)t' ~!'I'·.; ., STATE OF COLORADO DIVISION OF HOUSING JUN 27 2003 PLANS APPR~. S'J&!ECT TO Aa0 INSPEC..'TIQft ~ ' J 1: ~~~~ ~ <!' OS~~ • :I ~i ~ ~ §g zl ! 1:: ,__o ~ I'! T ~ ~ ~l,li ~ ~: z 'I ~ g:~ ~~~i a !1!:!1!: 00 I 1!li I~ ~~~ s ~ ~ 0 ~ ~ ~ 0 !~¥ I I 2: •• , >< :;!~§_ -...;~UI z ~"-~ ~-· 0 :I: 0 !>.< "' "' ..,. I "' 0 z 0 ~ :i 'i! 0 1-I 0 I.U ~t:ll! " ~ N ~Hij ~ I 0 " ~ ! I " I :i " "-0. 1 . so·-o· 47'-10;j;" 45'-&.i" OFFICE #1 OPEN OFFICE AREA FLOOR PLAN SCALE: 3/16"•1'-0" II MECHANICAL PLAN OFFICE ~1'/'D/c...l["f' 1"0tt-ft"f' p.t!.ctc..t·ntrs .Ptdd'~ A""""'"'SIS<-6 <Noi-Sirli ...,A{~.! ,.,_...,, II STP,TE OF COLOAADO DIVISION OF KOUSING UODULE (.0.) WITCHING DENOTES 3/8" SHEATHING ON INSIDE OF W.O.U. MODULE (A) APPROVED ... I "' 0 z 0 .... ~=1! 0 I-I 0 LIJ lltl!i " ~ ;::::! :t~ "' N m :!ei :->"') :i; 0 §: i I :> I ::;; "' 0.. ~ Y-~· • ) :5'-loi" Y-~· -PA~EL (A) IX ~ f./ lX ""~~· /1)<:: ""~~-lX \.L IX ~ ------~~t> ""~~. ' ...................... ' ""~~. = ' "-----... I ""~~ ' ------~-~ ' t't;, ___ , ' ' !? --._ ' 1.100\IU: (A) "l /1 IV "l VI D( "I ill • • REFLECTIVE CEILING PLAN STATE OF COlO~ An,... DIVISiON oF t.K)USiNG JUN 2 7 2005 INTERIOR SECURITY BAR DETAIL 3 1-~~ 1 Jl= l=b 1- --. 1 - II ~ I ' II J !i <I: ' II' I dl ~ I . ~-.6 ~ .01-.L • " co z 0 1- <{ > w _J w _J <I: 1-w 0 " . 0 z 0 1- <I: > w _J w (_) z 0 1- <I: > w _J w NOI!DlliOO~ Hlllll 03110Md'o' 0 NOUY-IlliOOI'I !nOHllll\ 03'-0M<Id'o' 0 ~ ~ ~ i ll ~ 0 ~ "' ~0 ~ oi'S zu • ~ " z~ "' l 0 ~ ~· ;::0 ~ Uz "' • i>l~ O! i~ • ~ ~ ~ ' ~~ zw oo ;i ' u~ ' ~ •• D z C'> ,, ~ ' ~w ~::; ~ ~ 0~ ow ~ ~ ~~ ooo ~ ~ ~ ~~ w ~ ~~ wu ~~ ' i l ! ! ! !l! 11 1 I ~ ~!~ ~;!:1 i (; _!' ~ ) / (,, !! llllji~ ~M~~!:• ~~~ ll XINtlOHd iM .,. I'll i, !I! "! '· '" ~'~' ~~:1: gh:! 1., CL, ""·~ l / ' • l ·~ !'1 ,,, ! ,B l!! '!' ~Gil ~oll· ( • ' !( 1! _;_ !l!!i V1 _j z _j <!: :3 11!!1 :3 D w <=l p w ~ ~ V1 f- ~ ~ ~ •" "" ~ •• i ;Cl •• ~~ ••• • ~~~ ~ ~ ~~ ~ ~ ~ i~~ !!!!§ ... ;;;;:. b!:i I _J ~ ~ • i ~ • • ~ v' r- If '----"' < • i i i ~q iM '''i I!! ( ihii ~:~i:l: ~~i~! ( l i Jill ;!iU i 1ii! lh:i ) (/) _jz <1!::. :3 D <=l p z w w ~ f-, r::q _j f-~ <[ • 1--- ~w p=-'1 ) ~ I ()) EXT. SIDING.ISHEATHHi ~~~ABLES "' 2'• STUDS AT IS' o.c. OON.1<fAT&'o.c,EliG£ oiNll 12" o.c. Flll.JD 16d JDX NAD..S AT 16' o.c. ICLDD\oiN STIMf' AT .'II' o.c. 6•7d 0. EM1 114' DWI. 3' LAG Si:RtiiS (ACII OUTRIGGER CHASSIS HAIMIAIL DETAIL c """ DETAIL 2 ·IIIII AT IZ'o.c.cr..,,..-....., 3 • lllmiTD tACH STUll 2"• STUDS D DE AIL E GENERAL NOTES' D ALL SHD'WN NAILS ARE ASSUMED Hl BE B!JX NAILS. 2> ALL LUMBER TD BE GRADE STAMPED BY AN APPROVED GRADING AGENCY. 3) REFER TO FLOOR PLAN CONSTRUCTION NOTES FOR ALL MEMBER SIZES AND GRADES. SHEAR\JALL TYPES <ALLD'JAilE UNTT SI£AR VIILU£S) -~ ,J~T£ ~AI. ~l\li., -·~~ ~ .!>. "'IMUAI<'o.c;DZ,I!" ... ~ mw ~ .. ~ .. ... n~~l4' ... <:J.k.:::'o<.~ u.sp;; 2Zi Pf m, "' 'IINAIUI<I:!'o.:.~IZ'o.c.Fn> = "'"' m"' ~~ D:IMU~I6'K.OIZ,IZ'<>e.FI!l,l ~ .. 141plf ~ .. !Ill !liltS"' 4' oc. Ell£ ... "" FI!U m,. m,, m" "" roou "' :r """ Ell£ r .... rno "'" ~ .. ~~ >< ~-............................. _ ......... "" .......... -,. ... ..... .. ---...... ..... ·-------..-·--................. ,.. "---,.-............. ---...... . .. __ ...................... _ ............. ..... ..ll'- ~ .. ~ .. >< ~ .. ~ .. = ~ 111 0 ~--------------------------------------~11~ IIF"==<I ll'miiiiMDr..mo...: ...... FASTENING SC EDULE CONNECTION TYPE tiAll lYP£ RArTER TO liD! RAnER "' ' '" liD! !W'TrR TO lD' PUITE '" TIP FUT£ TO TIP PUI '" 'llP PLATE TO $M1 '"' BD TIJI .IT = '" " PLA E TD " f1.!IR ,(liST TD ~ .ti!ST "' AID' Ja!<JNO Til OWTDIS " n.IIR IEOIK Til .lim; " oo. mJNI; lll S1\IIIS " ~ .... -............... ""'" REQIJIRE:!I 3 3 2 3 "· -SPA~lNG T&l6'o.c. 9' a.e. 16' o.c. ·- ·-~ ... ~""" STATE OF COLORADO DIVISION OF ;.;,r)us·~· ..... -"I'U JU1~! 2 7 2M5 !.:JJ!='ROVF.D XIN3:0Hd EXTERIOR ZONE WIND LOAD: --"s>l- .-rl 1 -----,- 1 --,-------, 1 I--,-I'NT---,-r-' ,_,zoNE WI-----,-ND LOAD--,----,' 1 oz P--,-LF ---,-,-rlliiJ .:lld DOt :QifOl 1WM301S Ild OBF :Q\'"01 lMINI'v'l"i SISS\>Kl I jld OBV :oVOl l~NI'v'rl SISS\fli:) .:fld oat :oval llVM30rs 09 0 « 0 __J " "' (/) w (/) (/) n_ " __J « ~ "' w 5 ,---- n I CJ w 6 0: CL CL ·:::( ~ ~ • ~ ~, ci < g a z I • w z a N ~ a ~ w ~ w PROPOSED SKINNER RIDGE CENTRAL COMPRESSION FACILITIES SECTION 36, T5S, R98lf, 6TH PM "'I~ '!o :il~ ~L:i i'm m~~ no ·;;!!! -'""' 0~ "~ ~~III'<()/~ ~::! 1~/'J I \ W 1/• CORNER SECTION 36, T!iS, R98W FOIJNO STONE W/POST LEGAL DESCRIPTION: CHEVI«lN PROPiR'l'Y I I / ' --'--Til~ TIIACT 104 ' /' // // // // /// ,; ~ /:/ II // I // t0:'/ A PAAC£L OF LAHD SITUATE IN TRACTS IOJ AND 104 LOCATED IN 11-IE NW 1/4 Of' SECTION JG, TO\\NSHIP 5 SOUTH, RANCE 98 1\E:ST OF' Tl'E 6T1-I PRINCIPAl. r.tERIDIAN, COUNTY Of' GARFIELD, STATE OF" COLORADO, THE PERit.!ElER BEING t.IORE PAATICUt..AAtY OE:SCRIBEO FOR AREA AS fOLLOWS: COMioiENONG AT A fOUND STONE IN Pl.ACE FOR THE W 1/4 CORNER Of' SAID &CTIOH 36, 'MiENCE A fOUND 1924 GLO BRASS CAP IN PLACE fOR lliE NORTHWEST CORNER OF" SAID SECTION 36 BrARS NOO'M'J9"W A DISTANCE Of 2643.36 FEET, WITH ALL BEARINGS CONTAINED HEREIN SEING RELATIVE THERETO: TliENa: N16'J8'~rE A DISTANCE: Of' 213.19' f'EET TO THE TRUE POINT Of BEGIN~NG Of THE PARC£l OESCRiaEO HEREIN: TliENCE N68'48'5J"E A DISTANCE OF 7+0.JJ fEET: THENCE S2511'JO"E A DISTANCE Of 507.55 f'EET: THENCE SM"Ol'Jil'W A OISTANct Of 681.02 F'E£1; THENCE N14'22'17"W A O!STANCE: OF 122.58 TO THE POINT OF BEGINNING. CONTAINING 11.19 ACRES MORE OR lESS. NOTES: 1} lHE P~OPOSE:O Sllf; AS SHO\\N ANO DESCRIBED ABOVE IS NOT A BOUNDARY SUR~ AND NO t.IONUt.I(NTS WERE SET, THE PURPOSE OF THE ABOVE ltGAL OESCRIP110N WAS TO DESCRIBE lHE PERit.IETm AND AREA 'o\llHIN CHE\IR.Crt-1 PROPERTY FOR lHE PROPOSED SKINNER RIDGE CEHTAAL COidPRESSlON FACIUTY. 2) THE CENlRAl FACIUTIES EDUIPt.IENT ARRANGEMENT AS SHOWN ABOVE WAS PREPAA£0 BY URS -WASHINGTON Ol'o1SION PER PLAN PBSR-598J6AVF-CIV-LAY-VRS-00000-00005-00, REV 0, DATtO APRIL 22, 2008. .. + . • GRAPHIC SCAlf; IN fEET ·--·10 mf CON&T~UCTION 6U~YI"r'e, INC. 6UNRIR BL.YC. eo ertt~2 SURVEYOR'S CERTIFICATE PBSR-fi9838AVF-CIV-SRV-CSI-00000-00001-U02 ~-~· ,.., to' ,,111: ltJ.IUI ~·, B' -11\U~IJIIClltJ.ILtJS ,.., .,. Wllt>ttg, 10rra: llllltll I,..,.,. IZJIII.O(IgtiJflll WILli I I "'•M' IZJIII.O(IgtiJfiCIItUUll l .... M' ctiiii.O(!gt IJFIII: IUILU I 0 0 ... ... I IO'oM'I._\111! I IO'oM' SIBU(;(\1111 I U'oM'IItll.l(l\1111 I I lO'oiO'II(R.OG(\1111 I I ro'oMI'SIO!.t«\1111 I • IO'oM'IJ'Ia IUILU ' \ ro'oM'SIBU«\1111 I ro'oM'IIBU«UUI I I IO'oM'IIgt.l(l .. !l I I IO'oM'Sigt.I({\Jifl I I IO'oM'IIlll.l(l .. ll I ' I \ \ I \ \ \ \ I I I I I _) i i ' I ' I I ' : I ! ' .......... ,. .... ,.1 G Washington CALCULATION Sheet No I SHEET C·Jkubtioll Nu. Chevr~n ;J,, ~A-V~C Pn.•jcct No. 2''154'2-PROJECT TITLE C'uk. By :./)2 t/ 0 7/z/<>8 Rev. SUBJECT/FEATURE oi+!~ L&;iou~~s:t) Chcchll By D~tc t,::;J "--:---.:£] I!' IZ 1 I ·'I [Jd-'~t (/-Jo"'b} Mew ·• ,, r(lb p < '" " ' oX Jt.' 1----) --<-... .. - . I -,-,1 r--·-C,,....;.t.b ,,. """'~ _,._J:1CE ,~'' i r;;f•f/-' I : 7 -P"" 17 i "'0 y{-it.t "' "' i 1:' ./\ I ~ "I _,._ ~~' ,;_,, I '-' " I I l!JI '"-' 0@ o??ld· ' #ict; 0 ocv~t$ I [R ,7f~'t i I _j ,. i p-'e >---0 0 / - (t -----··C.:_ --,- rf' fll'" I (31-! ()p~ili I -~ r"':-r-:ct '·' ' ~ ,A/\e"J ;\llP.t'/ or ,. ' -:TH~ ~~<[J ·' I ', 6o ' ' ,~\(tit (,v->:"'1 -f.,t "' f)rx.rJ JHt lr( ~ o< ,:;y \ ('~/ t.;<,;..> 1-' I ·I . /I J-o) lw\dO GARFIELD COUNTY BUILDING AND SANITATION DEPAR TMENT 108 Eighth Street, Suite 401 Permit 451 1 , .(, Sl) 2 Phone (970) 945-8212 l__. r'J , ~~ Glenwood Springs, Colorado 8160 1 Assesso r's Parcel No. ')I , -J l· ~D iNDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY This does not cons titute a building or use pe rmi t. Sys tem Location --=--+-..>....,.L'=>''-----'~+-'<-....loL..!...L...:-::-""--''--..!.......-'"---'---+--''----'----I-7'~""7'-="-tf'""""-'C1......<'------­ Legal Description of Assessor's Parcel No. -~-+-...C.....__J_--+-"=-~----"'-~~--=:........J.-+------------ SYSTEM DESIGN \~Ob "3Ll b0 Septic Tank Capacity (ga ll on) _____ Percolation Rate (minutes/in ch) Required Absorption Area -See Attached Special Setback Requirements : _____ Other Number of Bedrooms (or other) ___ _ Date ____________ In spector ------------------- FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Ca ll for In spec ti on (24 hours notice) Before Covering In stall ation System Installer ----------------,,----r-----::>r--:-+---=------------/ A t/'ir .. (.../ .. :1 ~ Septic Tank Capacity --------'-----------/-'-'-/ ____ ___,""'"-'''---:::__----- / ~~ -/ Septic Tank Manufacturer or Trade Name ___ __,?21"-•...:.'J..:.:/t'('+,-'-'f '---'-' r =f ~.:...Y' _ _.__ _ __:_I _,_.(;./,._? _:i-'1 '+-,-'-~"'---------/ / Septic Tank Access w ithin 8" of surface------------------------- Absorption Area--------------------------------- Absorpt ion Area Type and /or Manufacturer or Tr ade Nam e------------------- Adequate comp li ance with Cou nt y and State reg ulati ons/requireme nts--------------- Other _________________ ~~--~----~--------- Date --~!t..:..l_; --=-?"-1--=rJ'-"/ ..... )'---__ Inspector _ ___;_,1_(--=-rf---'-'.J'--...:.· ,--'/ ilc.:.r _(....:.'/,_,_l'_,_/-=-(_'· ________ _ RETAIN WI TH RECEIPT RECORD S AT CONS TRUCTION SITE CONDITIONS: 1. All installation must comp ly with all requirements of the Colorado State Board of Healt h Individua l Sewage Di sposa l Systems Chapter 25, Article 10 C.R.S . 197 3, Revised 1984 . 2. Thi s permit is valid on ly for con nection to structu res which have fully comp li ed wi th County zoning and building requirements. Connection to or use with any dwelling or stru ctu re s not approved by the Building and Zoni ng office shall automa tically be a vio lat ion or a requ ireme nt of the permit and cause for both lega l action and revocation of the permit. 3. Any person who cons truct s, alte rs, or installs an ind iv idu al sewage disposal system in a manner whi ch involves a knowing and material varia ti on from the terms or speci fi ca tion s conta in ed in the app li cation of permit comm its a Class 1, Petty Offense ($5 00 .00 fine-6 months in j ai l or both). Whit e-APP LI CANT Ye llow -DEPARTMENT GARFI ELD COUNTY SEPTIC PERMIT APPLICAT ION 108 8111 Street, Suite 401, Glenwood Springs, Co 81601 ..\,h_ \ ( l'\ (i 5 Phone: 970-945 -821 2/ Fax: 97~s;;3470 I Inspection Lin e: 970-384-5003 'J7T"" -=r\V \ Wl'fW.I!.: e -countv .com I Parcel No: (llli s inl01m ation is avai lable at the assess 011 otlice 970.945-9134) 2139-163-00-014 2 Job Address: [rf an address has not been assigned, please provid e Ct. Hwy01 Street Nam e & City) or and legal des~ion 2700 Clear Creek Road, P.O. Box 296, De Beque, CO 81630 -CPF located 2.5 miles north -northeast of end of CR 211 -about 19.5 north -northeast of De Beque 3 Lot Size: NA Lot No: Block No: Subd ./ Exemption : 4 Owner: (propetty ovmer) Mailing Address Atten : Ken Jackson Ph : Ail Ph : Chevron U.S.A. Inc. 11111 South Wilcrest Drive (281) 581-4991 (281) 435-0666 Houston TX 77099 s Contra~ Mailing Address 005 Power Line Road Ph : AI! Ph: Down alley Septic and Drain Rifle CO 81650 (970) 625-5556 6 Engineer: Mark Nothaft • Mailing Address 7800 E. Union Ave., p~303) 843-2092 AHPh: URS .IAI .... I.I '" Dlvl!llon Sui te 100 , Denver CO 80237 7 PERMIT REQUEST FOR : (X) New Installation ( ) Alteration ( ) Repair 8 WASTE TYPE : ( )Oweling ( )Transient Use ()()Commercial or in dustrial ( )Non-Domestic wastes ( )Other-Describe 9 BUILDING OR SERVICE TYPE: Tem~ra[i construction trailers to su~~rt Central Productton Facill~ construction Number of bedrooms ~on~ Garbage Grinder (x)Yes ( )No 10 SOURCE & TYPE OF WATER SUPPLY: ( )WELL ( )S PRING ( )STREAM OR CREE K ( )CISTERN If supplied by COMMUN ITY WATER , give name of supplkl r: 11 DISTANCE TO NEARESTCOMMUNITYSEWERSYSTEM: 19+ miles to De Beque, CO W•• en effort made to connect to tht Community System? Tempora~ regulrement-no effort made due to the lack of Infrastructure. YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: Depth to 111 Ground Water Table >20ft Peroa nt Ground Slope NA -tank storage 13 TYPE OF INDMDUAL SEWAGE DISPOSAL SYSTEM OSDS) PROPOSED : ( )Septic Tank ( )Aeration Plant ( )Vault ( )Vau~Privy ( )Composting Toilet ( )Recycl ing, Potable Use ( )Recyc ling , other use ( )Ptt Privy ( )Incineration Toilet ( )Chemical Toilet ( x\Other-Describe On-site storage tank-waste tran sported off site to Rifte wastewater treatment plant 14 FINAL DISPOSAL BY: ( )Absorption tre nch, Bed or Ptt ( )Underg rou nd Ois~rsal ( )Above Gro und Dispersal ( )Evapotra nspiration ( )SMd fi lter ( )Wastewate r pond (x)Othe r-Descri be aste trans~orted to Silt, CO, wastewater treatmen t ~lant IS Will effluent be discharged directly Into waters of the state? ( )YES (X)NO 16 PERCOLATION TEST RESULT: (b lie complet ed by Registared Professional Engineer, ~lhe Engineer does the Pen:ol ation Te sQ Minutes per inch in hole No.10 Minutes per inch in hole No.3 Minutes per inch in hole No.11 Minutes per inch In hole No.4 Name, address & telephone of RPE who made soli absorption tes t: NA Name, address & telephone of RPE responsible for design of the system : NA 17 Applicant ackn oWl edges that the comple teness Of the appliCation is cOnd iti onal upon such further mandatory and addttional test and reports as may be required by the local health department to be made and fumished by the applicant or by the local health department for purposed of the evaluation of the application ; and the issuance of the permit is subject to such terms and conditions es deemed necessruy to insure comp Uanoa with rules and regulations made, information and reports submitted herewith and requ ired to be submitted by the applicant are or will be represented to be true and OOITect to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein . I further understand~tion ~esentation may result in the denial of the appHcation or revocation of any permit granted based upon said appUcation _:~egalactionfor ~o / ~~ __ . ____ . __ /O/fli_.!?.e _____ OWNERS SIGNATURE l DATE *Permit a •Ilea lion ared b URS-Washin ton Division, 7800 E. Union Avenue , Denver, CO 80237 ; 303-843-2219 office ; pp prep y g 303 -526~514 (cell); Atten : Sally Cuffin STAFF USE ONLY Permit Fee : I PerkFee: Total fees : Bu"ii'\~~ Septic Permit#: Issue Date: Buildlag & Plaanlag Dept: APPROVAL DATE , I I ',, \ \ .. 'l I I I ~~ ,. [ ~ .·. (, URS Washington Division PICEANCE BASIN NATURAL GAS DEVELOPMENT PROGRAM Chevron 1111 GARFIELD COUNTY, COLORADO Calculations for ISDS for Central Processing Facility Temporary Office Buildings 1 0 Approved for Construction A Prelim . Issued for Review/Comments REV. DESCRIPTION BY CHKD APVD cvx DATE RVWD REVISIONS CLIENT: CHEVRON North America Exploration and Production PROJECT: Piceance Basin Natural Gas Development Program JOB NO.: 29454 DOC. NO.: Not Applicable C :\Documents and Settings\gatec534\Desktop\Copy of Chevron Temporary Office Buildings Calculations .doc URS Was hington Division Chevron li1 Date: 10/10/0 8 CALCULATIONS FOR CENTRAL PROCESSING Doc. No. Not Appli cabl e FACILITY TEMPORARY OFFICE BUILDINGS Rev: 0 PICEANCE BASIN NATURAL GAS Page : 2 of 2 DEVELOPMENT PROGRAM Chevron Temporarv Office Buildings Sewage holding tank sizing based on the following : 1. International Private Sewage Disposal Code -2003 (see attachments) 2. 18 people at the site 3 . 20 gallons per day per person 4 . 5 day holding capacity 5 . 2 ,000 gallon minimum holding tank capac ity 18 people x 20 gpd = 360 gallons/day x 5 days = 1 ,800 gallons Use 2,000 gallon tank (minimum tank capacity) /0-?-OS L. FEIST CHEVRON TEMPOKAR'I OFFice BUIL0/1-/GS ?~WAGe /loL.O!NG 7ANI< S!Z!N6 BASeD oN 7/IE. rtJLLOW/NG : /. 1/Jrei!.NAT!ONAL.. ?~IVATc. SeWAGe ols~osAL c ao£-2oo3 2 . IS ?t=OPLE AT rilE-51/C. 3, 2 D 6AlLoNS ?t::l<. DA '/ ?tEl<. ~ei(SoN 4 . 5 OA'i /ltJLOING CAPACITY 5 . .21 00D qALLON /vi!N!UUM f/IJLOJN6 TANK.. CAPACITY jg PeoPLe X :Zo G?O == 3'0 GALLoNSjOA'/ X 5 PAYs = ~goo 6ALLofls USe :2.1 ()tJD 6ALLoN TANK. {jvtiNIMUM 7AIVK cArAe~ri) \ TANKS TABLE 802.7.2-continued ADDITIONAL CAPACITY FOR OTHER BUILDINGS BUILDING CLASSIFICATION CAPACITY (gallons) Restaurants (24 hour)-kitchen a nd toilet wastes (per seating space) 60 Retail store s-customers 1.5 Schools (per classroom-25 pupil s per classr oom) 450 Schools with meal s served (per cla ss room-25 pupils per c lassroom) 600 Schools with meals served and showers provided (per class room) 750 Self-service laundties (toilet waste only, per machine) 50 Automatic clothes washers (apartments, service buildings , etc .-per machine) 300 Showers-public (per shower taken) Swinuning pool bathhouses (per person) For SI : I gallon = 3.785 L. SECTION 805 HOLDING TANKS 805.1 Approval. The installation of a holding tank shall not be approved where the site can accommodate the installation of any other private sewage disposal system specified in this code. A pumping and maintenance schedule for each holding tank in- stall ation s h all be submitted to the code official. 805.2 Sizing. The minimum liquid capacity of a holding tank for one-and two-family dwelling s shall be in accordance with Table 805 .2 . O ther buildi ngs sha ll have a m in imum 5 -day hold- ing capac ity, but no t less than 2,000 ga llons (7570 L ). Sizing shall be in accordance with Table 802.7 .2 . Not more than four holding tanks shall be installed in series. TABLE 805.2 MINIMUM LIQUID CAPACITY OF HOLDING TANKS TANK CAPACITY NUMBER OF BEDROOMS (gallons) 1 2 ,000 2 2,000 3 2,000 4 2,500 5 3,000 6 3,500 7 4,000 8 4,500 For SI: I gallon= 3.785 L. 805.3 Con s truction. Holding tanks shall be constructed of weld ed steel, monolithic concrete, glass-fiber reinforced poly- ester or other approved materials. 805.4 Installation. Tanks s h all be located in accordance with Section 802.8, except the tanks shall be not less than 20 feet (6096 mm) from any part of a building. Holding tanks shall be located so the servicing manhole is located not less than 10 feet (3048 mm) from an all-weather access road or drive. 805.5 Warning device. A high -water wa rning device shall be install ed to activate 1 foot (305 mm) below the inlet pipe. This device sha ll be either an au dible or an approved illuminated 34 15 10 alarm. The electrical junction box, including warning equip- me nt junctions, s hall be located outside the holding tank or hous ed in wate rproof, explosionproof enclosures . E lectrical r e - lays or controls shall be located outside the holding tank. 805.6 Manholes. Each ta nk shall b e provided with eith er a manhole not less than 24 inches (610 mm) square or a manhole with a 24-inch (6 10 mm) inside diameter extending not les s than 4 inch es (102 mm) above ground . Finish grade shall be sloped away from the manhole to divert surface water from th e manhole. E ach manhole cover shall have an effective locking d evice. Service ports in manhole covers shall be not less than 8 inches (203 mm) in diameter and shall be 4 inches (102 mm) above fini s hed grade level. The service port shall h ave an effe c - tive locking cover or a brass cleano ut plug. 805.7 Se ptic tank. The outlet shall be sealed w here an ap- proved septic tank is ins talled to serve as a holding tank. Re- moval of th e inlet and outlet baffle shall not be prohibited. 805.8 Vent. Each tank s hall be provided with a vent not less than 2 inches (51 mm) in diameter and shall extend not less than 12 inches (305 mm) above finished grade, terminating with a return bend fitting or approved vent cap. 20031NTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® • \ TANKS TABLE 802.7.2 ADDITIONAL CAPACITY FOR OTHER BUILDINGS BUILDING CLASSIFICATION CAPACITY (gallons) Apartment buildings (per bedroom-includes au tomatic clothes washer) 150 Assembly ha lls (per person-no kitchen) 2 Bars and cocktail lounges (per patron space) 9 Beauty salons (per station-includes customers) 140 Bowling ce nters (per lane) 125 Bowl ingcenters with bar (per lane) 225 Camp, day use on ly-no mea ls served (per person) 15 Campgrounds and camping resorts (per camp space) 100 Campground sanit ary dump stations (per camp s pace) (omit camp s paces with sewer co nnection) 5 Camps, d ay and night (per person) 40 Car washes (per c ar hand was h) 50 Catch bas in s-garages, motor fuel-di spensing fa cilitie s, etc. (per basin) 100 I Catch basins-truck washing (per tru ck) 100 Churches-no kitchen (per person) 3 Church es-with kitchen (per person) 7.5 Condominium s (per bedroom-includes automat ic clothes wa she r) 150 Dance halls (per person) 3 Dining hall s-kitchen and toilet waste-with di shwasher, food waste grinder or both (per meal served) 11 Dini ng ha ll s-kitchen waste only (per meal served) 3 Drive-i n restaurant s-all paper service (per car space) 15 Drive-in restau ra nt s-all paper service, inside seating (per seat) 15 Drive-in theaters (per car space) 5 -"" " Em pl oyees-in a ll bu ildin gs, per empl oyee-tota l all shift s 20 Floor drains (per drain) 50 Hospital s (per bed space) 200 Hotels or motel s and touri st rooming houses 100 Labor camps, central bathhouses (per employee) 30 Med ical office bui ldings, cl inics and dental offices Doctors , nurses, medical staff (per person) 75 Office perso nnel (per person) 20 Patients (per perso n) 10 Mobile home park s, homes with bathroom g roups (per site) 300 Motor fuel-dispen sing facilities lO I Nursi ng and rest homes-without laundry (per bed s pace) 100 Outdoo r s ports fa cilities (toilet waste only-per pe rson) 5 Parks, toilet wa stes (per person-75 p ersons p er acre) 5 Parks, with showers and t oilet wastes (per person-75 perso ns per ac re) 10 Restaurants-dishwasher or food waste grinder or both (per se at) 3 Restaurants-kitche n and toilet wastes (per seating space) 30 Restaurants-kitchen was te onl y-without di shwasher and food waste gri nde r (per seat) 9 Restaurants-t oilet waste only (per seat) 21 Re staurants (24 -hour)-dishwasher or food waste grinder (per seat) 6 (continued) 20031NTERNATIONAL PRIVATE SEWAGE DISPOSAL CODE® 33 w l!) <I 0.. CXl IS) IS) N ....... (Y") ...... ....... f--'7 li 1 l IS) ~~~~ f ··- ~7 ~~ a ~ no con '""' 11f<:s I ~-~ I'I.OCIO<W F·"' 9£: W>0<4X> M ~!;- ]<7390(. ) r~ _f1.39D r ~ A 1\ ' 1--\ 'Poe f- ! r-f- ~ ~·· ~ r ~~ •375 t- i"2A' . 7 ~7 ~7» . . . . l.--J'!. 7 r:!:-4 - )<'-( ROTONICS MFG . I NC . DVG BY • s .~u-1. DATE : 3.2€>.07 \ eo. ;oo J l~rrf'(8:<) I'-~ : t O · .,.., ;... :; -( b-7? (2 . elf ·:, -:: ,: