Loading...
HomeMy WebLinkAboutOWTS Design Layoutfie MO".fB't-1~r a.a· :t ~ ~SOGA ~ CONCR£TJ. "'-.. SEPTIC TA "'-.. W\TRAFRrt "'-.. RATED LltP ~ SLAB I ~-'"<I' ~ "~ (_() ~+ T.) "V " . " " " / " '--- {OWTS) DESIGN LAYOUT PLAN /1'- _..,... - , Atllar ~ Oap -a-No. SllU SU. ~r!: sin. = 1100.6 ' '2-<o "'o~ N ' FEET 40 O 40 FEE T 111111 1 1111 I GRAPHIC SCALE 1 inch = 40 ft. CONTOUR INTERVAL :::: 5 FEET NOT£S: 1. CONSTRUCTION ANO INSTALLATION OF (OWTS) SHALL 8£ IN ACCOROANC£ WITH GARAELO COUNTY STANDARDS ANO SPEC/RCA noNS /( RULES ANO REGULA llONS. 2 . S£C TYPICAL 0£TAILS ON SH££TS 2 THROUGH 4. J. CON TRACTOR SHALL CONTACT ENGINEER PRIOR TO CONSTRUCT/ON FOR SYSTEM LA YOUT LOCATION. (OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVIS ION GARFIELD COUNTY, COLORADO APRIL 14. 2016 SHEET 1 OF 4 PINNACLE JJESIGN CONSUL TING GROUP, INC CONSll. TING CNGINCERS • 0805 BUCK POINT RlJAlJ CARBONDALE1 CO 81623 e <970) 963-2170 TYPICAL GRAVELLESS CHAMBER PLAN, SECTIONS, AND DESIGN CALCULATIONS ~ TO D/STRIBU710N BOX 2X GRADE MIN. DESIGN CRITERIA: /NFIL TRA TOR WITH ACCESS ENO PLATE\ ' AT GRADE 1. HOUSE SIZE -{4} BEDROOMS 2. DESIGN LOADING -525 GPO 3. Ai.£RAGE PERCOLATION RATE -37 MP/ OR LT (LTAR) = 0.5 4. MINIMUM ABSORP710N AREA R£0UIR£D FOR GRAV£U£SS CHAMBERS = (525 GPO /0.5 CPO/SF) X (1.0 FOR TRENCHES) X 0.85(CHAMB£RS} = 892.5 SF u NOTE: FULL CREDIT FOR CHAMBERS WAS NOT REALIZED OU£ TO ROCKY SOILS. S. 892.5 SF/(12 SF/CHAMBER)= 75 (OU/CK 4 INFILTRATOR CHAMBERS J' X 4) (# CHAMBERS/ 5 TRENCHES) = (75 CHAMBERS/S TRENCHES) = 15 CHAMBERS/TRENCH IN 5 ROWS (PROIAOE MIN. 6' S£PARATJON BETWEEN EDGE OF TRENCHES) 6. USE 1,250 CAL SEPTTC TANK PER GARFIELD COUNTY REGULAl10NS FOR A FOUR (4) BEDROOM HOUSE ~ ~ . ...,.. /NSP£Cl10N PORT AT BOTH ENOS OF TRENCH 6' MIN 6' MIN I 6 0' I ~ 15 CHAMBERS PER TRENCH .- PLACE PIPES IN TOP PORT OF CHAMBER A T END PLATES 4' DIA SOR-35 P~ PIP£ (TYP.) LIMIT TYPICAL PLAN V7EW -INFIL TRA TION TRENCHES SCARIFY BOTTOM OF TRENCH GRA VELLESS 'OU/CK-4' CHAMBER ( 4'X3') OF EXCAVATION TYPICAL SEC710N -INFIL TRA TOR TRENCHES SLIP-ON PVC CAP DON'T GLUE SLIP-ON PVC CAP OON'TGLUE ~ 4" OIA. SOR-.JS SEWER PIPE N.lS. AN!SH£0 GRAD£ INSULA TEO =•=1= /COPPER / TRACER WIRE '---II ;9 I""'"* .f." DIA. SOR-35 INSPECTION PIPE FILTER MEDIA N. T.S ROUND ~ /RR/GA llON VAL 1€ COVF:R ~ ilJimjP 'NISHED CRADE (4) 1/4" HOLES DRILLED INTO SIDE OF PIPE FOR VENTILA TJON BELOW SLIP-ON PVC CAP ~~'*' (OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO APRIL 14. 2016 SHEET 2 OF 4 TO SEPllC TANK TO HOUSE INSP£CnON PORT DETAIL PINNACLE DESIGN CONSUL TING GROUP, INC. CLFANOUT DETAIL N. r.s. N.lS. CONSUL TING ENGIN££RS e 0805 BOCK POINT ROAD CAl?BONJJAL£ CO 81623 • <970> 963-2170 SEPTIC TANK DETAIL FIBERGLASS CASKETED LID WITH S TA!NLESS STEEL BOLTS OR SEALED CONCRETE LIDS SLOPE GROUND A WA Y FROM RISERS PVC RISER WITH GROMMETS (BOND TO TANK ADAPTER WITH RECOMMENDED ADHES!VF} OR CONCRETE RISER WITH f ~ RUBBER-NEK "'' 11mw.•rn;:;:!11 q "' ~ ~ INLET TEE EFFLUENT FROM 4" PVC SEVER SERVICE@ -2% GRADE MIN. L!OUID LEVEL ~ t' TANK ADAPTER (CAST OR BOLTED) EFFLUENT DISCHARGE @ -2% GRADE NOTE: 4" ORENCO BIOTUBE EFFLUENT FILTER OR APPROVED EQUAL A SEPARATE (OPTIONAL) HIGH WA T£R ALARM MA Y BE INSTALLED ALONG WITH AN ALARM PANEL AS PART OF THE INSTALLATION (OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO 1,250 GAL. BAFFLED SEPTIC TANK APRIL 14. 2016 SHEET 4 OF 4 N. T.S. PINNACLE DESIGN CONSUL TING GROUP, INC CaNSUl. TING £NGJNE:ERS • 0805 BUCK POINT ROAD CARBON/JAL£, CO 81623 e <970J 963-2170 DISTRIBUTION BASIN DETAIL - PIPE TO FIELD ~ ~ PIPE TO FIELD ... -i..... ~ OUTLET NOT USED ._ __ CONCRETE DISTRIBUTION BOX • I I I I ~ , , --~--r-I I .. LJ I I ---=-__l_I . BAFFLE AT INLET END INLET ' ALLOW ACCESS FROM ~ FINISHED GRADE U? TH CONCRETE OR FIBERGLASS RISER AND COVER PLAN VIEW -DISTRIBUTION BOX PIPING N. T.S. (OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO APRIL 14, 2016 SHEET 3 OF 4 PINNACLE DESIGN CONSUL TING GROUP, INC. CONStA. TING £NGIN£ERS • OBOS BUCK POINT ROAD CARBONDALE. ca 81623 • (970) 963-ZJlO ru Nlfl'.fB''4-.,,.- l.5.,R' / o'o --:2~0CA ~ ·. CONCREn '-..,, SEPTIC TA '-..,, W\TRAFRG '-..,, RA TED LltP ~ SLAB I ~~ . "<~ \) ~+ ':) 'V """ "' "' """ """ '-- (OWTS) DESIGN LA YOUT PLAN /1'~ ........-- '\ , 10,00· Eu#marif\AT flf4t / / ./ Af. //~~ ( .. ~1'}gr ~Olp S~ Na. SllU BmclullArt EWv. = 'Jt00.6' • ~b \,,.OJ(,. N l FEET 40 O 40 FEET 1 1 111111111 I GRAPHIC SCALE 1 inch = 40 ft. CONTOUR INTERVAL = S FEET NOTES: 1. CONSTRUCTlON AND INSTALLA TlON OF (OWTS) SHALL BE IN ACCORDANCE ffof TH GARFIELD COUNTY STANDARDS ANO SPEC/RCA TIONS ct RULES AND REGULATIONS. 2. SEE TYPICAL DETAILS ON SHEETS 2 THROUGH 4. J. CONTRACTOR SHALL CONTACT ENGINEER PRIOR TO CONSTRUCTION FOR SYSTEM LAYOUT LOCATION. (OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO APRIL 14, 2016 SHEET 1 OF 4 PINNACLE DESIGN CONSUL TING GROUP, INC. CONSlA.. TING £NGINfEJ?S • 0805 BUCK POINT ROAD CARBONDALE~ CO 81623 • <970> 963-2170 TYPICAL GRAVELLESS CHAMBER PLAN, SECTIONS, AND DESIGN CALCULATIONS ~ TO OISTRIBU"flON BOX 2X CRAD£ MIN. DESIGN CRITERIA: /NF/l TRA TOR Ptfn-1 ACCESS ENO PLATE\ . ATGRA0£ 1. HOUSE SIZE -(4) BEDROOMS 2. DESIGN LOADING -525 GPO 3. A llFRAGE PERCOLA nON RA 'TE -37 MP/ OR l1 (l TAR) = 0.5 4. MINIMUM ABSORPTTON AREA R£0UIR£D FOR GRA V£U£SS CHAMBERS = (525 CPD /0.5 CPD/SF) X (1.0 FOR TRENCHES) X 0.85(CHAMB£RS} = 892.5 SF o NOTE: FULL CREDIT FOR CHAMBERS WAS NOT REALIZED DUE TO ROCKY SOILS. 5. 892.S SF/(12 SF/CHAMBER) = 75 (OU/CK 4 INFILTRATOR CHAMBERS .J' X 4'} (, CHAMBERS/ 5 TRENCHES) = (75 CHAMBERS/5 TRENCHES) = 1 S CHAMBERS/TRENCH IN 5 ROWS {PROV/OE MIN. 6' SEPARATlON BE~EN EDGE OF TRENCHES) 6. USE 1,250 GAL. SEP71C TANK PER GARFIELD COUNTY REGULA710NS FOR A FOUR (4) BEDROOM HOUSE ~ ~ -"11- ......_ ___ ., 'v 6' MIN. ., , ,,_.....,. __ _... ; ..._ ----I LIMIT /NSPEC710N PORT AT BOTH ENOS OF TRENCH SCARIFY BOTTOM OF £XCA VA TION OF TRENCH GRA llFLLESS 'OUICK-4' CHAMBER (4'XJ') 6 ' MIN 6' MIN I 60 • I ... 15 CHAMBERS PER TRENCH ., PLACE PIPES IN TOP PORT OF CHAMBER AT ENO PLATES I .f.' DIA S :/PIP£ (;:,5-Js PVC TYPICAL PLAN WEW -INFIL TRA TION TRENCHES ~l\'5:· N. T.S. TYPICAL SECnON -INFILTRATOR TRENCHES SLIP-ON PVC CAP ROUND Im /RR/GA TION VAL~ CO!.£R SLIP-ON PVC CAP OON'TGLU£ ~ 4., DIA . SDR-J5 SEWER PIPE TO SEP llC TANK N.T.S. ANISHFD GRADE INSULATED ™ /COPPER / TRACER WIRE TO HOUSE CLEANOUT DETAIL N. T.S. DON'T GLUE e:s1a1k: i 1atm 'NISHEO GRADE (.f.) 1/4w HOLES DRILLED INTO SIDE OF PIP£ FOR llFNTllA 710N BELOW SLIP-ON Piie CAP ( OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY. COLORADO APRIL 14. 2016 SHEET 2 OF 4 INSPECnON PORT DETAIL PINNACLE IJESIGN CONSUL TING GROUP, INC. N. r.s. CONSUL TING ENGINEERS • 0805 BUCK POINT ROAD CARBllNDAL.£, CO 81623 • (970) 963-2170 EFFLUENT FROM 4" PVC SEVER SERVICE @ -2% GRADE MIN. SEPTIC TANK DETAIL FIBERGLASS GASKETED LID WITH STAINLESS STEEL BOLTS OR SEALED CONCRETE LIDS SLOPE GROUND A WA Y FROM RISERS PVC RISER WITH GROMMETS (BOND TO TANK ADAPTER WITH RECOMMENDED ADHESIVF) OR CONCRETE RISER WITH ~ , ~ RUBBER-NEK o m: I &;;;ti Q II \I f k' ~ y LIOU!D LEVEL _LI, ,I I J 1,--., !< ,I 2" TANK ADAPTER (CAST OR BOLTED) EFFLUENT DISCHARGE @ -2% GRADE NOTE: 4" ORENCO BIO TUBE EFFLUENT FILTER OR APPROVED EQUAL A SEPARATE (OPTIONAL) HIGH WATER ALARM MA Y BE INSTALLED ALONG WI TH AN ALARM PANEL AS PART OF THE INSTALLATION {OWTS) DESIGN LOT 25 S11RLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO APRIL 14, 2016 SHEET 4 OF 4 1,250 GAL. BAFFLED SEPTIC TANK N. T.S. PINNACLE DESIGN CONSUL TING GROUP, INC, CONSLA.. TING £NGIN£ERS • 0805 BUCK POJNT ROAD CARBONDALE, CO 81623 e (970) 963-2110 DISTRIBUTION BASIN DETAIL .. ~ c. I I I PIPE TO FIELD / 11 6J ~ PIPE TO FIELD I ! f...... <.':) <: I I CONCRETE OUTLET ~--~ DISTRIBUTION NOT USED --BOX I I I I ~ '1 I I • -"---l I -LJ I I ---_LI . ~ I 7 I I# I BAFFLE AT r INLET END 1\ I INLET \ __ ' ALLOW ACCESS FROM ~ FINISHED GRADE U1 TH CONCRETE OR FIBERGLASS RISER AND COVER PLAN VIEW -DISTRIBUTION BOX PIPING N. T.S. {OWTS) DESIGN LOT 25 STIRLING RANCH SUBDIVISION GARFIELD COUNTY, COLORADO APRIL 14, 2016 SHEET 3 OF 4 PINNACLE DESIGN CONSUL TING GROUP, INC. CONSUL TING ENGINEERS • 0805 BUCK POINT ROAD CARBONDALE. CO 81623 • (970> 963-2170