Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Oflice:970·945·8212 Fax: 970·384-3470 Inspection Line: 910·384-5003 Building Permit No. _L/2/CJ Parcel No: Locality: 2177-104-01-014 --·=----'- Rifle Service Park PUD, Lot 14 -~------z.D-t-14-o-dd..r-i's ~:-&I c; & Job Address: Lot 13 & 14 Rifle Service Park ··-------~-- Use of Building: ---·--install 6' chain link fence ------···-- Contractor: Owner Fees: Plan Check: 181.51 Septic: .,,w ___ , __ ,,~.----·- Bldg Permit: 279.25 Other Fees: Total Fees: $ 460.76 Clerk: zpiJ11L4P~ Date: _L2 'I,_Q!L_~ I GARFIELD COUNTY BUILDING PERMIT APPLICATION !08 8'' Sweet. Suito 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-:184-34701 Inspection Line: 970-384-5003 www. ·~rt'ield~counlv.cmn Autlwrjty. Thi:> ilf!PI.ieation i'or a BulldiDg Ptrmi~ ml,13t be sigMd by the Owner oflhl: P•'Ut).n'ly, &~crl\;JI;d a bOw, or 11.11 aut.horizcd <~a.~nt. if ik aigmWJ.ru bdow is not thil\ ol' rJll!: Owner,~ ~epru'll.tc lt:t~' of authority, \11J:>!led by~ OWih~t. m.usr be pwvlded wi!h thl~ ApJ,Hcalloo. LM{II A~. A Buildine P~;~nillt CllQllot b~ h~ul:ld without p,\,luf' of legnl umi <tl.lt:quahl ncc.:ss to u~ Pl'cperty fur 1'1,1.rpos~ of in~)1~c!.ion.s by t~ Jlui!d.ing ~partn~~:ut. Oth~r l~rmltG. Mul~ipl~ 1;1/lftru'll.te pmniW mily be rcquir~d; (I) Sratc Elt:etrli.:~lllei'mit, (2) CQ\.mty l'SDS Ptotrtlh, (3) anotht:r ~~~miri~qai[l:.d fo1· ul!C on tll.~ property idcotif1~1l ~(IV~::, e.g. Si;itl~ 1,11' CouutY Highway/ R~11c1\l Accl!fla or u SW!h Was~wuti::r Dhcbatge Permit, y11iri.Pem'llt. A Bui1LU1\S, I~L·mit btXH..JJl~~ ilull and \'oid if U~i,~ W<>rk authori:ted is not comm-:nced within ISO !.lays of filt:; ill! II: l)f iosunnce ;md if work i~ :;u:;pt;~tlr;k=d or abUJidl.lu~d for s period Q)' lSU day~ uiwr COll~ncem~ot. Cl!:R'l'l'FICATlON -, !~(~>by et:rtii)' UH"~ i hav~ n:ud tlli~ Application undl.ht~L d'l~; iL)form~l\kn conw.iued ubov~ i;; l!.'tl~ nod em~:~,:~ I uock.r~tuml ~lilit \he Blllldlng Dl!pan:menl ~~Jllt ~ Appl\!,:;,~\lca'l, along with tbl! plans ;,utd ap~citic~tiun$ ~nd other di\t.l ~~,~btnlncd b~ 1m' i,'ll'th) n'ij behalf ($1.1!,-unittals), ba~~l,l !,l.jH)Il roy ccnifi~;atiqtl as to accur>wy. A~suming; compretend;a of ttn: ti\lbmiuals and npJ)l'(l~i! of !his Appl\~tion, u Buildina: l~t·mit will ~ i~~~d gL'tlnting p~:mU~~ion to n~~:, ~Owner, to (,.1.)1\~I:I.'U.Cl. the ~lrut.:~\lt~(s) and f11cili~l<::> d~milt::d on rlk. subm.iti.;;IJ~ J'i.!Vh.."Wed by ~h~;~liuitdiog Dl:p01ri;ll~<:llt. In considl:r;ukul ohb~ issuilnl.--~ of W Bui1di-J~,;Jl1 (!'rnlit, 1 ugr~ ~hU\ l n.nd my ug~nl!:: will compl~ wilb p~ovJsion~ of uny fe;do.rnl, SUI\JI! or looollnw rt:aulati~ the work and tht: Gurli~Jld c~)tlf.lty Building Colfu, ISDS l't!lgulnlions Mn4 llpplicnbie lt~n~ w;-e tcgulndon~ (C:~u..tl~ty R~gulutiQn(~)). l aclrnowll!ds~ that th~ BuildL11g l>~mit llliiY b~: ~uspdlded or n;\'Okcd, upon nt.>\.b;~ from ;k. Cou11ty, if d~~:; locntion, con~lnK:Uoo or uot: ofth~ eu·ucture(~) 1111d l'acility(i~o), dl;~~,;db~!:d abovt!, iiTt: nut ln comptitmct: wirh County R~tulildon(5) or i:lrty clhet•npplicab~ l&W. llu;~t~by gram pt::rml~t~!on to ~ Bu('!Qin£ Depnitrlklm-w 1,511\:ill' the prop1;1rty. <h3sc-dbcd nb~;~w, !.U inspect th~ wol't::. l further <~cluiDwiOOge th<lt 1he iss\l.OII\lt: ~1'\lu: 8uilding ~mh dlll!s not prev~tm U!~! Building Ofliclil) ftom: ( l) tt:(juiriug tht:l correctio" ¢!' &rors in the ~ubt:Oiuals, if uny, l,!li;<.:U\'I!!l.<.:;d nfu:r b~'\1\lHCl-l": or (2) ::ll:oJJPillg constrUII~kiu DL' uac of tl1~ sl.!'uC(Ute(s) or f.tcilily(u~e) if such i~ in violation uf Count~· R~;:g~o~l<~tio.n(a) or uny ~lh"'1' applicable Ji~w. R~vicw of thi:; AJ)pli.cr!lion, i ~ubmitml~. i.llli.l. iuspcctio:ru; of ttl\! \l'od:. by tht: l~ulidiug.'I:Mpllrtmt:nl. (!o not coo~tit\J\1; Wl acc~plruw~; tJt'l\';sporu,ibilHy Ot' liability by ~h~ C:~~.nuy of errorj;, ~~Jrl.i~tion-s ot· di~cr~rutci~\>. As the lhil~ru~ponsibility rcr tomplianct: wilh J~tful'ol, au1re ~nd lccul !.nws and Cou.llty 'RegulatkHlS tusc wilh u~ and my nulhori:.:~;:(l agc.rus, incltJdilll;; without 1in1i.tatiw1 blllklcL AND I,JNbERST AND THB NOTlCli & CERTIFlCATION ABOVE:: STAFF USE ONLY Special Conditions: Adju,tod Valuation: Manu home Fee: Mise Fees: TotalF..,s: 4ko .1L7 }"ees Paid• ! '6\ _5! ~ & '"'"" Dute: ISDS No & Issued Date: 1; 211· 1-1 o/. or OCCGroup: Const Type: I\"' AP R'('fV AL "-J DATE APFltOVAL DAT.E i' \jtr -~ ~~ .....__, 't Q ~ .... ~~ i\( Z' sft~~ £2;::: . cJG {... \"" ~ <> "- "(~ ~ \)-. ----" ~ I() 1:!:' ..... 'It '\) ((_~ ~' ' "- '1--(' -~ '"\:, '4 . .., ., ' ;).:/' GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with mo1·e than ten (10) oc.::upants 1·equires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24"" and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade 1 line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house·rap, (which is requiTed), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. A window schedule. A door schedule. A floor fran1ing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 3 6 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IBC, IPC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: 1. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each comer of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stan•p on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivisiou final plat shall be prepared by a licensed surveyor and have the surveyors signature al1d professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the propomtructure located within the envelope. Yes . 2. Does the site plan when applicable include the location of the l.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certitled by a licensed surveyor with their signature and professi011al stamp on the design. Yes NA Not necessary fur this project __ _ 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes_x_ 4. Is the l.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? Yes . Not necessary for this project ,4/A-- 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifyingthen1 as "Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes X Not necessary for this project. __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in acc~e :l!'ith the building code or per stamped engineered design? Yes . Not necessary for this projec~ 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes~ ot necessary for this project# 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required l;>eiween w. ood a:1;1? Yes4Jt Not necessary for project 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffil!l'? · , Yes_ Not necessary for this project#- 10. Do the plans include design loads as required m1der the IBC or IRC for roof snow loads, (a minimum of 40 pounds per square foot in Garfield Com1ty)?/ A Yes __ Not necessary tor this projec~ 11. Do the plans include design loads as required for floor loads under the IBC or IRC? Yes __ Not necessary tor this projectAL;4::: 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes __ Not necessary for this project~ 13. Is the wind speed and exposure design included in the plan? Yes __ Not necessary for this project4LJI=. 14. Does tl1e building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes __ Not necessary for this project# 3 15 _ Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes __ -_ Not necessary for this project# 16. Does the elevation plan indicate the height of the building or proposed addition from the undistutbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Yes __ Not necessary for this project.$ 17. Does the plan include any stove or zero clearance fireplace pla1med for installation including make and model and Colorado Phase II certifications or Phase 11 EPA certification? Yes __ Not necessary for this projectM-· 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? Yes_ Not necessary for this project~ 19. Does the plan include a window schedule or other verit!cation that egress/rescue windows from sleeping rooms and/or basements comply with the £4--ements of the lBC or IRC? Yes_~ Not necessary for this project · 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? _ A/ JL._ Yes __ Not necessary for this projectnr,.a:_ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walki11g surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes __ Not necessary for this projectJi;/= 22. Do the plans include a complete design for all mechan~ktems planned for installation in this building? Yes_ No Not necessary for this projec 4 23. Have all areas in the building been accurately identified ibr the intended use? (Occupancy as identified in the IBC Chapter 3) Yes __ Not necessary for this projectM:- 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes_~ Not necessary for this projectM 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? AJ1J Yes __ Not necessary for this project-lJfJ'I:- 26. Do the plans indicate the location and dimension of restroom facilities and if more than four employees and both sexes are employed, facilities for bo~s? Yes __ Not necessary for this project . 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes_~ Not necessary for this projectL:\Lii 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes~ · 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes~ 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes1,_ 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For comer lots see supplemental section 5.05.03 in the Garfield County ZonirigResolutiot1 for setbacks. Yes X. 32. Do you understand that approval for design andJor construction changes are required (!rior to the implementation of these changes? Yes~ 5 3 3. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes--A;-- 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes)(__ 3 5. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project n1ust comply with the Unifonn Codes? Yes~ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday.lnspeetions are to be called in to 384-5003. Yes-A- 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $So.:x·inspection fee? Yes 38. Are you aware that prior to submittal of a building pem1it application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge peiin!t;a Colorado Dept. of Highway Permit including a Notice to Proceed; ·a permit from. the federal government or any combination. You can'contact the Road & Bridge Department at 625-8601. See Phone book for other agencies YesL 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes_)(_ 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcell Schedule Number for the lot you are applying for this permit on prior to submittal of the building permiXplication? Your attention in this is appreciated. Yes 41. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes~ (Please check with the building depru.tment about this requirement) 6 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes__ Not necessary for this project.4::4-- 43. Did an Architect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and specifications for the project. Yes__ Not Necessary for this project /1% A I hereby acknowledge that I have read, understand, and answered these questions to the best of my ability. ~ ~~ 12-g. Date Pho!Jetl$0 0 {;) 7£ (days); (evenings) Project Name:-'-fi...._'i"\-"W~c.===-g>==='----------- Project Address:~ CR v 1 1 < .e_ '?4-J?h.. j.erh 15 4 I~ Note: On any of these questions you may be required to provide this information. lf required information is not supplied, delays in issuing the permit are to be expected. Work may not proceed without the issuance of the pem1it. *If you have answered ''Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Date Issued _1/.:.._,Z='t"-'-.-'0'-'9''-------------Permit No. II 2J_Of ____ _ AGREEMENT In consideratio.n of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building deP-artment and IMMEDIATELY BECOME NULL AND VOID. useJLr.bfilO Un\'--tffiLfl ________ _ Addr~aiDescription Q.lf\e.8erv\~Q""""-------­Own.;;d_t)~.ili\dd_ Contractor_,Q...__,._W"\,.._,_,{y'-'1'------- Building PermitType-C,o.~J------------------------ This Card Must Be Posted So It Is Plainly Visible From The Street Until Final inspection INSPECTION RECORD Footing Driveway Foundation I Grouting Insulation Underground Plumbing Drywall Rough Plumbing Electric Final (by State Inspector) (Prior to Final) Rough Mechanical Septic Final Gas Piping FINAL -1-cJJ-of ~ Electric Rough (by State Inspector) (You Must Call For Final inspection) (Prior to Framing) Notes Framing (to include Roof in place & Windows & Doors Installed & Firestopping in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970-384·5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ~::eROVED /. lq. oq 1= .. YlnYVIt't '~ J "----PR_O_T_E_CT-P:~~~~1tt::---PJ'O) (DO NOT LAMINATE) Parcel Detail Garfield County Assessor/Treasurer Parcel Detail Information Page I of 4 AssBssor/T r~psur~xJropBrtyJ)]:larch I As~BSSm:JubsBt UuBry I AssBSSor SaiB~. Smch ~IElfk HHJJcor@r RBrutiqn SBar:~.h Uasic auilding Char.Q~tBri~tics I T a)(lnformatio[J Pax~.O!ltail I YJJIUB D~tail I Sal B.~ DBta.U I RBsid!lntial/l:;.omm~_rciallmprovE)J]lBnt o.~tail JandJJBtail I Phm.Imra.phs I Mill lgy'£R~vBnues Detail I Tax Area II Account Number II Parcel Number II2DD7 Mill levy I I 021 II R21DDI8 II 217710401014 II 48.431 I llwner Name and Mailing Address !JOHNSON. DAVID !55 COUNTY RO 317 !RIFLE. CO 81850-8455 Assessor's Parcel Description (Not to be used as a legal description) ISECT.TWN.RNG:I0-8-93 SUB:RIFLE !SERVICE PARK P.U.D. LOT:I4 BK:0517 IPG:0875 BK:0880 PG:0551 BK:0590 IPG:0202 Location I I I I I I I jli====P=h==ys=ica=l A=dd=r=es=s: ~l~=IR=IFL=E ======ill http:// www.garcoact.com/ assessor I parcel.asp?ParceiNumber= 21771040 I 014 12/9/2008 Parcel Detail I I I I I I I I Subdivision: jjRIFLE SERVICE PARK P.U.D. I Land Acres: jjD.975 I Land Sq Ft: jiD Section II Township II Range I 10 II 6 II 93 I 2DD8 Property Tax Valuation Information II Actual Value II Assessed Value I Land: II 74.32DII Improvements: II Dli Total: II 74.32DII A_dditional V13Jue Detail Most Recent Sale Sale Date: I Sale Price: I Additional Sal~_s Detail Basic Building Characteristics Number of Residential jD Buildings: Number of Comm/lnd /D Buildings: No Building Records Found Tax Information 21.55Dj Dj 21.55Dj I I II Tax Year II Transaction Type II Amount II http:/ I www.garcoact.coml assessor I parcel.asp?ParceiNumber= 217710401014 Page 2 of 4 1219/2008 ParcBI OBtai! PagB 3 of4 I 2007 II Tax Payment: Second Half II ($500.30)1 I 2007 II Tax Payment: First Half II ($500.30)1 I 2007 II Tax Amount II $1.000.801 I 2008 II Tax Payment: Second Half II ($292.88)1 I 2008 II Tax Payment: First Half II ($292.88)/ I 2008 II Tax Amount II $585.38j I 2005 II Tax Payment: Second Half II ($293.81)j I 2005 II Tax Payment: First Half II ($293.81)1 I 2005 II Tax Amount II $587.821 I 2004 II Tax Payment: Second Half II ($285.74)j I 2004 II Tax Payment: First Half II ($285.74)1 I 2004 II Tax Amount II $531.481 I 2003 II Tax Payment: Second Half II ($294.74)1 I 2003 II Tax Payment: First Half II ($294.74)1 I 2003 II Tax Amount II $589.481 I 2002 II Tax Payment: Second Half II ($402.52)1 I 2002 II Tax Payment: First Half II ($402.52)1 I 2002 II Tax Amount II $805.041 I 2001 II Tax Payment: Second Half II ($411.17)1 I 2001 II Tax Payment: First Half II ($411.17)1 I 2001 II Tax Amount II $822.341 I 2000 II Tax Payment: Second Half II ($422.54)1 I 2000 II Tax Payment: First Half II ($422.54)1 I 2000 II Tax Amount II $845.081 I 1999 II Tax Payment: Second Half II ($201.27)1 I 1999 II Tax Payment: First Half II ($201.27)\ I 1999 II Tax Amount II $402.541 http:/ I www.garcoact.com/ assBssor I parcBI.asp? ParcBI NumbBr= 217710401014 12/9/2008