Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970·945·8212 Fax: 970-384-3470 Inspection Line: 970·384-5003 Building Permit No. Parcel No: 2139-163-00-014 Locality: Job Address: _________ ?zoo_glear Creek Rd. DeBeque Use of Building: ________ t-'-el-'-'-ec~ .. J1l.fl1_!JnJ~~!ions_b_ui_ld_in,_,_g ___ _ Owner: Chevron Inc. Contractor: Elkhorn Construction Inc. ·-----··---=:.:..:..=.==::.::..:.:.=-- Fees: Plan Check: 72.31 Septic: Bldg Permit: $ 111.25 Other Fees: -~·-"·"~'"~ """-"""--·~·~·-· .. ·-· Total Fees: $ 183.56 Clerk: Date: ~-q~a_C}(_ I I GARFIELD COUNTY BUILDING PERMIT APPLICA T!ON 108 8m Stree~ Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212/ Fax: 970-384-3470 /Inspection Line: 970-384-5003 www.garfield~county.com Parcel No: (this infonnation is available at the assessors office 970-945·9134) 2139-163-00-014 2 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description 2700 Clear Creek Road, P.O. Box 296, De Beaue CO 81630-CPF located 2.5 miles north-northeast of end of CR 211 -about 19.5 north-northeast of De Beoue 3 Lot No: NA Block No: SubdJ Exemption: 4 Owner: (property owner) Mailing Address: 11111 S. Wllcrest Olive Ph: AltPh· Chevron U.S.A. Inc. Houston, TX 77099 (281) 561-4991 (970) 257-6042 5 Contractor: Mailing Address:218145112 Road Ph: Alt Ph: Elkhorn Construction, Inc.' De Beoue, CO 81630 (970) 283-1009 (970) 625-4180 6 Architect I Engineer: Rodney Burrows Mailing Address: 12567 W. Cedar Dnve, Ph: AltPh: ZAP Engr & Canst Services Inc. Suite 210, Lakewood, CO 80226 (720) 529-4430 (971) 533-6665 7 ~'lz6Vf1~"M~in~ tt> S~ Ft. or Acres of Lot: Height: No. of Floors: 40,600 sq. ft. (CPF primary pad) 10.7 It Single story 8 Use of Building: Telepommunlcatlons Building 0 houses telecommunications equipment required lor site communications and remote eauioment monitoring I control · 9 Describe W01k: Foundation Installation, placement of modular unit, and utility hookups 10 Class of Work: ~New o AJteration o Addition II Garage: Septic: To be pennitted with CPF NA o Attached o Detached IIi! JSDS restroom bldg oCommunitv 12 Dri»'Xay Pennit: t" \(fJ\.Ao\-:!)0\( c _)CJ...\-';f, . Owners valuation of Work: $ 181,000 ' '· NOTICE ~. This application for a BW!ding Pennit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. Legal Aliet!' A Building Permit cannot be issued without proof of legal and adequate access to the propmy for purposes of inspections by the Building Department. Otbfr Permits. Multiple separate pennits may be required: (I) State Electrical Permit, (2) County ISDS Permit, (3) another pennitrequiml. for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not conunenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certifY that I have read this Application and that the information contained above is true and correct. I understand that the Building Department a«:epts the Application, along with the plans and specifications and other data submitted by me or on my behalf(submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure{s) and facilities detailed on the submittals reviewed by the BW!ding Department. In consideration of the issuance of the Building Pennit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Builcfing Department to enter the property, described above, to inspect the work. l further acknowledge that the issuance of the Building Pennit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or fucility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County ofenors, omissions or discrepancies. As the Owner, J acknowledge that responsibility for compliance with federal, state and local Jaws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or bWider. I HEREBY ACKNOWLEDGE THAT l HAVE READ AND UNDERSTAND THE NOTICE & CERTIFICATION ABOVE: ~-·{!_, OWNRSSIGNATURE ~ /.Jv.."z--r.f' / 1 /;:s_hooc:r 'DATE . Elkhorn COnstruction, Inc. Will install foundation and place unit URS Washington Division assembled permit application (Contact: Sally CuffiQ'rURS Washin.Jtlon Division, 7800 E. Union Ave., Suite 100, Denver, CO 80237 Oftioe: 303-843-2219, Cell: 303-526-6514) STAFF uSE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: ?~-3/ Permit Fee: Iff. .)S Manu home Fee: MiscFees: lf3?~,-0p -' ( ISDSFee: 1 Total Fees: I fJ 1 %, 1}~3. ~w Balan:0: ~ .jjjj.~·· ~ & Issued Date: . - Setbacks: OCC Group.:s -z_. Cons~~ Zoning: BL~EPT: ~~ > , ·~ ·~~' APPROV . \--,.-DATE v~~~~ P~G DEPT: ~~ 1 ~~~--~J~ b/_~[W!( APPROVAL ' 'DATE VALUATION FEE DETERMINATION Applicant Address Date Chevron U.S.A. Inc. Subdivision 2700 Clear Creek Road, De Beque, CO Lot/Block ______________ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Garage: Carport: Total Crawl Space Total Decks/ Patios Total Valuation Valuation Valuation Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation sq.ft sq. It sq.ft sq.ft X $74.68 0 sq.ft Commercial sq.ftX $41.00 sq. It X $33.68 sq.ftX $18.00 sq.ft X $12.00 sq.ft X $9.00 sq.ft X $24.00 sq.ft X $12.00 120 sf X sf X sf X sf X sf X sf X Telecommunications Building 0.00 0.00 0.00 0.00 0.00 .3'5 ,(]() ·- 't)-.60 , U\) GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS FOR CONSTRUCTION OF . COMMERCIAL OR MULTI-FAMILY RESIDENTIAL BUILDINGS Including NEW CONSTRUCTION ADDITIONS ALTERATIONS 1\nd MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan and in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Plans to be included for a Building Permit must be on draft paper at least 18"x 24 '"' and drawn to scale. Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony steps, hand rails and guard rails, windows and doors, including the finish grade and original grade line. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. Check with the Building Department. 1 A window schedule. A door schedule. A floor framing plan, a roofing framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. windspeed, wind exposure B or C, and a 36 inch frost depth. All sheets need to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be in compliance with the 2003 IBC, !PC, IMC, IFGC, and IFC. Applicants are required to indicate appropriately and to submit completed checklist at time of application for a permit: l. Is a site plan included that identifies the location of the proposed structure, additions or other buildings, setback easements, and utility easements showing distances to the property lines from each corner of the proposed structure prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Slopes of 30% or more on properties must be show on site plan. (NOTE: Section 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyors signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat, shall include a copy of the building envelope as it is shown on the final plat with the propo•ecl structure located within the envelope. Yes X 2. Does the site plan when applicable include the location of the I.S.D.S. (Individual Sewage Disposal System) and distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? This information must be certified by a licensed surveyor with their signature and professional stamp on the design. ISDS will be permitted with Yes Not necessary for this project X permanent restroom building 3. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes X 4. Is the I.S.D.S. (Individual Sewage Disposal System) designed, stamped and signed by a Colorado Registered Engineer? ISDS will be permitted w~h Yes Not necessary for this project X permanent restroom building 5. Are the plans submitted for application review construction drawings and not drawings that are stamped or marked identifYing them as ''Not for construction, for permit issuance only", "Approval drawings only", "For permit issuance only" or similar language? Yes x Not necessary for this project. __ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the building code or per stamped engineered design? Yes_x_ Not necessary for this project __ 2 7. If the building is a pre-engineered structure, is there a stamped, signed engineered foundation plan for this building? Y es_x_ Not necessary for this project __ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes __ · Not necessary for project_x_ 9. Do the plans indicate the size and location of the ventilation openings for the attic, roof joist spaces and soffits? Yes __ Not necessary for this project_x_ 10. Do the plans include design loads as required under the IBC or IRC for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County)? Yes_x_ Not necessary forthisproject __ 11. Do the plans include design loads as required for floor loads under the IBC or IRC? Y es_x_ Not necessary for this project __ 12. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes_· _x_ Not necessary for this project __ 13. Is the wind speed and exposure design included in the plan? Y es_x_ Not necessary for this project __ 14. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Y es_x_ Not necessary for this project __ 15. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes_X_ Not necessary for this project __ 16. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Check applicable zone district for building height maximum) Y es_x_ Not necessary for this project __ . 3 17. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or Phase II EPA certification? Yes __ Not necessary for this project_x_ 18. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IBC or IRC? Yes __ Not necessary for this project_X_ 19. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IBC or IRC? Yes __ Not necessary for this project_x_ 20. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes __ Not necessary for this project_x_ 21. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes __ Not necessary for this project_X_ 22. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes_X_ No Not necessary for this project. __ _ 23. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the IBC Chapter 3) Yes_x_ Not necessary for this project'---- 24. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes_x_ Not necessary for this project __ 25. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? This project will utilize an electric Yes __ Not necessary for this project_x_ HVAC system. 26. Do the plans indicate the location and dimension of.restroom facilities and if more than four employees and both sexes are employed, facilities for both sexes? Yes __ Not necessary for this ~-X-Restrooms located at separate facility building 4 27. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes__ Not necessary for this J*":ieet_x_ Restrooms located at separate facility building 28. Have two (2) complete sets of construction drawings been submitted with the application? Yes_x_ 29. Have you designed or had this plan designed while considering building and other construction code requirements? Yes_x_ 30. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes_x_ 31. Do your plans comply with all zoning rules and regulations in the County related to your zone district? For comer lots see supplemental section 5.05.03 in the Garfield County Zoning Resolution for setbacks. Y es.-'-x'--_ 32. Do you understand that approval for design and/or construction changes are required prior to the implementation of these changes? Yes_X_ 33. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit" fee as well as any "Septic System" or "Road Impact" fees required, at the time you pick up your building permit? Yes_x_ 34. Are you aware that you are required to call for all inspections required under the IBC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes_x_ 35. Are you aware that the Permit Application must be signed by the Owner or a written authority be given for an Agent and that the party responsible for the project must comply with the Uniform Codes? Yes_X_ 36. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made between 7:30a.m. and 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5003. Yes_x_ 5 37. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes_x_ 38. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? Tbis may include (but is not limited to) proof of your right to use a private easement/right of way; a County Road and Bridge permit; a Colorado Dept. of Highway Permit including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See Phone book for other agencies Yes_x_ 39. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups? The license number will be required at time of inspection. Yes_X_ 40. Are you aware, that on the front of the building permit application you will need to fill in the Parcell Schedule Number for the lot you are applying for this permit on prior to submittal of the building permit application? Your attention in this is appreciated. Yes_x_ 41. Do you kuow that the local fire district may require you to submit plans for their review of fire safety issues? Yes_x_ (Please check with the building department about this requirement) 42. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes x Not necessary for this project __ 43. Did an Arcbitect seal the plans for your commercial project? State Law requires any commercial project with occupancy of more than 10 persons as per Section 1004 of the IBC to prepare the plans and specifications for the project. Yes Not Necessary for this project X 44. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes Not applicable for this project 6 I hereby acknowledge that I have read, understand, and answered these questions to the best of my ability. Date Phone:2'li'/-5?29 -715"$'(days); 2"?/-"2%-12'1 S' (evenings) Project Name: Chevron Piceance Basin Natural Gas Development Program Project Address: 2700 Clear Creek Road, P.O. Box 296, De Beque, CO 81630 Note: On any of these questions you may be required to provide this information. If required information is not supplied, delays in issning the permit are to be expected. Work may not proceed without the issuance of the permit. *If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. BpcommDec2007 7 August 29, 2007 Mr. Fred Jarman, Director Garfield County Building & Planning Department 108 8'h Street, Suite 401 Glenwood Springs, CO 81601 Re: Authorization to. Represent Chevron - James s. Talbot Senior Couhsel Sally Guffin, Washington Gri:ibp International Inc; Dear Mr. Bean: Law o~·p~f1:m~nt North America Exploration and Production Company 11111.5. Wilcrest #N2006 Houston, Texas 7.7099-4397 Tel 281·561•3536 Fax 2.81·561-3515 )talbot@ChcivrOn.com Chevro.n U.S.A. Inc. (Chevron) has retaiue:d the services ofSally C~tffin of the Washington Group Intemationallnc .. Ms. Guffin will represent Chevron in facility permitting for our Piceauce Project i!l Garfield Cqun,iy, a role in which she will prepare and submit Special Use Permit Applications, ISDS, building, grading, pipeli)le, road q~qssing l\Ucl other rqutine construction related applications and information on behalf of Chevron. Ms. Guffin is also authqrjzeci tq participate in discussions qefote appointe:d and ele.cted boards regarding the various applications, however atsuch meetings, her authorit)' tq legally bind Chevron is limited to the tenus set fo1th in the Perl11it Applications or other written documents filed on our behalf. Sincerely, cc: Nicole Johnson Timothy Barrett Sally Cuffin From: To: CC: Subject: Date: Attachments: Jake Mall Cuffin, Sally; RE: Driveway permit exemption Thursday, November 06, 2008 1:25:38 PM Sally: you are exempt from the driveway access permit requirement for this project. Jake -----Original Message----- From: Cuffin, Sally <Sally.Cuffin@wgint.com> Sent: Thursday, November 06, 2008 12:48 PM To: jmall@ garfield-county.com <jmall@ garfield-county .com> Subject: Driveway permit exemption Jake, I just realized that I never got an official driveway exemption email from you for buildings at Chevron's Central Production Facility. The facility is located about 2.5 miles north of the end of CR 211 (near the confluence of Tom Creek and Clear Creek). Let me know if you have questions. Thanks! Sally Cuffin (303) 843-2219 (303) 526-6514 (cell) No. ----------~1~12~2~4~---Assessor's Parcel No. 2139-163-00-014 Date 2/4/2009 !BUILDING PERMIT CARD Job Address ----~2~7~0wO~cillle~a~r~c~re~e~kwr~d~,uP~e8~eq~uweL-______________________________________ ___ Owner·_ ------~C,..,b.I.Se.,v~rown"'--"'U""S~A,___ _______ Address 1111S. Wilcrest dr. Houston PIOOfJJel# 281-561-4991 Contractor Elkhorn Constrution Address 2181 45 112 rd, DeBegue Pl!?bffel # 970-283-1009 Setbacks: Front ________ Rear ______ RH, _____ LH _________ Zoning ____ _ Telecommunicatins building Soils Test--------------- Footing------------------ Foundation ______________ _ Grout _______________ ___ . Underground Plumbing------- Rough Plumbing ------------ Framing, ___________________ _ Insulation--------------- Roofing----------.--------- Drywall ----------------- Gas Piping---------------- INSPECTIONS NOTES Weatherproofing _______________ _ Mechanical ___________________ __ Electrical Rough (State) . ~ Electrical Final (State) j.. -g-{ 0 Final"fo .-n~to /Checklis~ CoQlgleted? Bm. Certificate OccupanQ~# i O:t.Ol.O . Date l S~GLE() 2. I 21. 10 Septic System # ---------------- Date ------------------Final _____________ _ Other __________________ __ (continue on back) Ul GARFIELD COUNTY, COLORADO INSPECTION WILl NOT BIE MADE UNLESS nus CARD iS POSTED ON THE JOB Date Issued---<!~"' -t./· 91 Permit No. ll.H.tJ __ _ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NUll AND VOID. use ~Mv.n\aJioo buHditl~q· _____ _ Address or legal Description _2.._']j)Q Oeo.r' (J:_~.£,\<..l2d.""."----1)t~ owner CJne,v'mn contractor _E\_.:l(.:echo,_,.,..._(_.O'-'------- Building Permit Type~,-------------------------- This Card Must Be Posted So It Is Plainly Visible From The Street Until Final inspection INSPECTION RECORD Footing Driveway Foundation I Grouting Insulation Underground Plumbing Drywall Rough Plumbing Electric Final {by State Inspector) 2 -'6-!0 ~ (Prior to Final) Rough Mechanical Septic Final Gas Piping FINAL 1--J?-ID K}vv\ Electric Rough (by State Inspector) (You Must Call For Final !nspettion) {Prior to Framing) Notes Framing (to include Roof in place & Windows & Doors installed & Firestopping in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection C.ll970-384-5003 Office 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ~::eR_ov_ED__..:A'-'-·-l,"'-,.,-""'0-'9'------By_._~~="f-'"-'-~f-!~_.:_o_r-__ _ PROTECT PERMIT FROM WEATHE DAMAGE (DO NOT LAMINATE) Inspection Report COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT I CORRECTION NOTICE Date Received: 08-FEB-1 0 Permit Number: 671618 Contractor/HomeOwner: SPECIALIZED AUTOMATION SERVICES LLC Address: Type of Inspection: Action: 2700 CLEAR CREEK RD Complete Final Accepted Comments or Corrections: 1) 314.25 Cover, faceplate, luminaires or canopy required for boxes (gutter cover in control room) 2) 35 kv switchgear clerances must be maintained 3) 110.3(B) Usted and labeled equipment shall be installed and used per listing and labeling (em light not working) 4) 210.8 (B)(5) GFI required (Non residential) Sinks ;, where receptacles are installed within 1.8 m (6 ft) of the outside edge of the sink. 5) battery cover required 480.9(B) Batteries, Live Parts. Guarding of live parts shall comply with 110.27 6) Installer on site making corrections Inspectors Name: Cyrus Tuchscher Phone Number: 970-625-5085 Date: 08-FEB-1 0 COLORADO STATE ELECTRICAL BOARD DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https://www.dora.state.co.us/pls/real/Ep_ Web_Inspection_GUI.Process_Page Page 1 of 1 2/9/2010 STATE OF COLORADO 10' x 12' x 9' Wood Frame Building by Dupont Building Inc., LA. for State of Colorado approval CALCULATION INDEX ITEM PAGE Information 1 Loads 2 Roof Joists 3 Wall Studs 4 Header 5 Floor Joists 6 Steel Beams .7 Foundation F Lateral Roof L1 Lateral Floor L2 Lateral Walls L3 Lateral Anchorage L4 -----~ Oc!PoNf -------------------=~~:__:~~~~-----<-'··--!S-----~---"'---N·--·c···-·-1-J-----~-------- ! f'~LcJC:.L--T jc 't-!1':/ '7-) 1 /";4-GFAB. 0}.Pt?!:::. l':::,vtt...J::JrrJ.C. bY brJf"',rrJT 6r/IL-D tr-J;:, ;/Vc:-. 1 LA h12--5/~>T.G. #/" C-c-t.--6/Z.Al>CJ Alo/-'/.Ui'VAL- :!?!t;I.,G. C/-C-oU>JLAIJcP ,£6cpt/1~G,NTS Z,t?t1_3 j;J/~4{/&J,--JAt-/5(11?1::;,/IJh U/Y;, A.5"c::b 7-c; Z- JU;,;/'Jf-J.&c.-!r-i.h ,' Asr...-1 AM5 1 .0~Z--A!J£ .fa ~/'J.c:./26/e.; iJ£-si4N P ~"' Z-Sat r::;; r C 5/-'G:c.FY 3vC-P r-'5 1 ) -.5-1£15!-Z-I ,<~3,;::; I -.... -------· ... -r-----.. ---------~-- 1 L>?Jt:---rs : £'*16£.!> _ A 3.:?7 1 :5---tA;,.J ~s 3.:?4 c "?f :::-5& ~~') /'t:--YAJoot::,; ,Psi-,Y.S · I Lt-~M6<VZ-;-:2---~ 4-St?P'/,LJ6Z-N /"l_,JtE _5;--;-t/6 Cli. "'85d /"'S I\ I 2--X? ~tPtJ7'!f6£-N fi,JG-il:z_ c J'b"" /?-5d ?"SI )-I I I tJ ;rJ6. /tf<P /I"'P~ ; 6-Xr;p-St/fZ-tE G- ~ ::o ?-.:r.rs_, .. "' /.Z-ICt)/-1>.:; ::-/Jl, Z-/'sr-"-/'"'-Z---/-lsC-G. 7-<'Z;SE<-. ?-4·!"'·' ~ Co>~r,s ) -= ~ ( :;;h-1 I J =' ~ FAS<§,. ~ .g Fv s, "' ~ {/, -"'d ) {'t?.$?) ""'~5-z­ ~ (. c:..e-e,) ( c,/3 ) =--cJ,/o .::> /::::,A:56. ~/-JM/2-::::. r..St>s ~ =' ;,e_(,y5-z._) vJ/.6:,::; :;. Cf.t?:JC- ,AL.-vrJAS,t.-!3: Gi-Jb?:.l1.--:::: a.7t:. ::: o.?{Li'.#!W)::: (},tu&v.l I I : I ~ ! ··--·--· .. ·--··---J·--··-·--·····. L ·-·-~------------·-------i.. ----------------------------.. -----------------------~"·-------------·-·-·--.. ~-~ ·---------~ I .. yll !Loor: ~ bf:.A f) -7/k C-fldi"I'.G:b rl&M:-t;LA55 --/,I %-" Pt-YINR'cJ G I • t; 2..-X G ,Joi:Sf (!? l?''"'b I· 7 j;JGtJl-Af/tP,J • 7 ~" rtz-1"' /"'?)';JNZ:.:. I ,5 !tlt5<-6L-L-AN661/'ii. I'::; -------· 8' .t> ;PG;:; i I 2, ...... . . .... .... 1--····· ··-··· ;:> G.lz-jV £ ~ -/IJ .!?:> 1 j;o /3, c.£. "" V ~" ilL-/'£-YfA}tMb Nl/fJ APA :9"AtV 1£-/r/1/11/1 Z-4# A,-<"1::, ~12- jpt:J P6i= L-ti/G ?~/!C:. P'N 6Vr/""t1'4{ ;SP,ae-IN/1 CJr I?''% > 5<P z-)( 4 I -r;o.F 8./.Z-Gd::::. 6/"'Af'i .::. { IIJ '-#" ) -c 3-t.") ::5 ;'<',a c:-; ;-J,::, ::: I c, " "'/""'" tN ,:--{' 5~ -1-fb ) ;:_ ::-7 7,?!;, pd- _c;t.,!__.lt_ -./ -<::::;).......-~ - . 1 ~71 I I I ! i ?r .I rC:..t:, == 1 /Rtf-6 /'f.SI ::2:-lz..Gocft:>)!-t5 ~ I• c.t-JEE.L--/L. ;Sf}G..a/2__ Pv"' ;,:; V/A ~ l-35 (77,3){ ~,;._~<> 1/G{3,n) C.!J;:;.,;.../.<:-bli'..FC-6 c:.-7; tJN o1 "" CJt; Je. -::. [I -r dn,;? (-67 )j .s>G ::. <f,s z,.. r "'-bel /;z.-""' /,5 {4-6 z.)/;z.. =-/1,tJ ;ruf IJC-<1 "'-J-z/'-sl < jfo (;,!G) 1 Ll. ,_ 5Nf..4 5(77,3)(},71) (!z.)"-t.f,~9"c 0..//~9 3 S-f 6 1:: "' 3 6-t ( 1;£-tJO I C>t!t) ) / 1> C> ;:::; C./-IG..G-1""-!/P.c..lr:r ~r.urr ,; ;.zJDJC,)(-33,tJo.) ""-3:t,J7/'SF i£.:,_,q;tJI'l ~ [ 8-J,J,?;J ( ~) { ~.;.,) "' -Z/3,/ /6$ ~ e-pe?-k<-r:;,sraJEE/Z.. S /Jot:-6/~.h ,Pc..YAJCJ&>/::, &6c~ f:>vo-F'AST /l)Au-s ,(,.<?66"4' ><-17-:i"J ?'=-/3o<5,?, -'f6 "' /3<?6 Co-M)-f-Ct:f,CJ66) (1-7G -<1-·1-7.) "'" 3.3-/ I I bvPorJT : : I 4 -+-------------···--·--·-··--··-j __________________________________ _l _________________________ .............................. -.--l--- NM-<-;:51JGA1'J-JirJj. /'~E4-;JWL--1 oo , JPsL-G 11: v ~" J'k:-/"£-JI!Nt?CJI~ Nr?!-1 APA :;5P/oAl /h<!lf!NI; ZO/c; h""'""<:,. f'"d1Z-- 6t? /"&r L-1 v6 uA.c c;rJ 6t.Jr"P#<VT :6f?A?/iJh CJr ;,:; '1 ~ > z-7, o Z-)<: 4 1 Sx "'"3,o.? ;!'/?> 1 Xx ::-fi,::,lb ;rJ 1 f?PPN "-L_} t-o") •' 3{J~lt) "' 6 '--7 ~11 "" ,5,t-·~: 6/"At:-!r-1 ;1 :::-It-11 ~""' r;.""" ~ ;, z..u::.t)C/'l 1?-4 .,_ z.c;,G-/"51" //•llii-J!f ::-j, Z I L I J C' JC-Z:>.o ';) ~ -Z7. 6 /'SF ..,____ C~N(;.t-6<-$. N --::. C 2-7' l> J :;.. ;:;, ::>7, I ,Pq='" .?IJGC:..k!o= · /3r6Aib-/ rJ,?, .. /'1" Nl ""/o ;.37,/C6-~s)";/c>:::. 34-? te-~/6:::, b"c.t> fb "'-lvf/:=;.::;. ::!Yf?CI,. )/3.&~ -:=-1.3-55 r"&l < 666(/.1.,;; )/,? "'-IG<t:4 Lc..- ,u,z-- C-IJF!i£?k-:5/-16-AIZ---• <=.t, /-v ,_f,611 /A "'-j, 5{37,/ ){&<::S/;;;..-\~,6C .3-6)"" f?P:>I ~ _yo Lt-?) ?!-1&L--IL-L-orJ/lJF!i£?{/&rJ G-rt>l:> /"6' /"?AT-!3. (tJt> #3s?, .6P&"-Mi6f ;J/Ji"-'S {, 1"'-l"cf ;><. 3'' J p--. z.-C;,:;&.tJ{j.c.){-",c;,?)(_f_:_£_) "'-z:-17/h-s-c._ /.?CI,z--- ; :z.{". t?,t) .?f-)6?1£--.-""f.//!.L- f_t;_/rJ "'1(6-?s )1z../s-6 :::-z..J,&> . Ft:--t:"" k&:£'/t:R.eAJ) "-::o iJ, 3 C!,1t:~t?t?t:?CJ \/cz.9-?) z-"" -177 pe-e/ h.~ -;;:. <1 7 J /.775 i 1.1-G: ) r:"':'--d'-, 4-':-'3.:=,-----:-::--;- C..;:> ~ C 1 .;-e1,43 )/ z-C-6) -I{, eJ)"--o,fo/ f5 ""o-IS6 I P ~"" 0c1 $ [t.G_,.,.s) (. '-!: )-~-e-o)]L./;:) /;.G C>-5) ""'66Ps1 < f76{usJ,<>f "'1"-" . I I ·, .. - 7Wo z.:y.t s 1 5.<"'-7.5C.(;z.)!r!3 1 :Z::X:"-zo,.sc-z-\lrJ.,1 >'(1"'-z-,t>?L""'J!Ns -:5~ArJ ::; 36-1l_,_ z..;:.'}(h-f-;.j;/' :::. .tj-P, Z6 11 :::r. 3.3>£ 1 N -:;. { 66 ·!-6 'j L !f::-) -1-z..-{ e:;) 1-z.-{ z.) " 3CJ (, /"a"- £!JG?/?-!3&orJlJ ;;J J, M"" NL .... /6 "'3ot:.UY3G).._/e:,~.t{3tjll:--lbs .Pb " fo'l/s .,. 43t O-v)/J,fo?C-z-') =-.34z-l''=>t < !u;.c> L;.t6 ) ?/-JIG.<:--IL.-:5>f./IE:41Z--3 36 /11 "" /.GV/A-= ;,:;; (:st:>z-l {. ~-)/;.sc;;.-5)z--" 17 ,PsJ.-e..Yo .?;.J €-c:.-e.-b t=.6:: .. r;;c..r /li,J 4 -:o. 6MJ.£:f ""' .O:L3c<?)(3,3.4 ':/ (_;,..):s ::: #. rtt:s.''::.. f!J::;,..,'f-3 36 fe.:t:: :sg-f (;, C:oo ,,J<t~) {'u..dj v .?-IJ b£--1-<--N 1 .rJ 6 it/ ~(-37,1) c 7~ )" --/.?7 Jv!~'vlt/c;. .::./1/7(3--s-s \/.c." 9sA Pf-/b 5 P6 "'j3-4 !.'1• 'yz,t>t>{~).~ Z?z-/":51 <.lz-5.(;,,;.) "'-Z.&<>c> ? !J 6."'-/?-& IY?/3 ;,J If!-I~ 3-fZ-..r ;t..?Z--::: d.z-4-!-0,11 ::. .;?,:<>6 .,:;.J I 4 S 6 Z-"'t:><7 ! 5 ······--.. ·1-------------·- 1 ----f-vr._, tv-~------------------j _____________________________________ L___________ _ _____ _ ________________ --!---------~--- ;::'e-Mit---:5!--IG-/.!-J"i·f I ;J h i i ~,qz_ /J.G-1£--IN> I ~ &U!f. 1}: 1/ I~,, 712-~t-'/NtJ'&>0. h/IT/--1 APA 1,.&-Pb ;:::&r,__. z.;Jc /",;;/--u U,;;_ CL>Ab t>rv~c, -1~ ;::-~cM/Z-GP~ &.a/IN,t +s':.~, ,:~;rJ svrP-1r---1 :5P/i ~f'-ih .& r-1 -z-4" -"/~ > /6 () C--3. X. 4-, I 1 5x =' /,fcJ ;,.1 3 , Z:x ~ /, ??/Ai1 6/".AC./;J /, "' b" &/"" N "' (_ 15,:;-t-/.& _) ( ~) -1-4-·1 = II I Pt-F r:'~ {_5ME!:.)(';)C.!f%:_) ::-I:H /k; r"'>Z--t/fi)IF#17tvt """·""~ !A./fl. --'7eo.j:s,f?>? ~ ,?•'Z--1> J2._ 1 -::. tf,(,{(A)j._-= t1,fRI{/JIJ3•6?"" !Z ,_ "-tl r{. j,z_ "\ -z.-(Z-t-t) ::--Got; M I :-8 7 {_,76)/-z--"' 3"/ Pt--!k"" /'1,_,_ ~ /74(/,67/,_) -.3f =-/i'z-/!?-lbs /11 .. -:--z-51 ( t.-. Z:7 />--'!, -/ ,p-;z.. =-I 6 J p t -lb "- r<'n-" ?&FJC-EAl(JZ.-,o?';;;;_ 6 L,_., /c:,S /Z-, <-/J4 { 3.U+,ytJ/o,.B?" i~ 11 _ " -z--1 194-Z--fv)" -JC.!ts ,_ p -. f<l{,--;;_ IJ4 {_,Jt; J"" lbt t&--lb:;, /rll7.-"" 4-6 (_ 3 . ?!t:-':r I es c. :s ----&-- L-/-1 {;,c;..tc--!sb'J.!;, /IJ;; Pb " M/s -=-{ 31 +-l&c;,) tz__/J, I"' ::: i I 1 VJ J I A~r: rtf+~+~ /Z--i 1!!-z--tz-1 1 111 1 -76'4}~.: t !,e~ tl-~6' Z-&1 5o6 Z?f i I~ /S7 Z51 17'f {:74 JJ-4- 1 ~ • I .jt,' 3,.1'>~ 3.6u'l *'19? I ! z-1-z.-9-? 2-4 Z-i /Jt ! dl . I I d 4-& ?f--l E;_C--k--G/--Jf£4 rz___-- Pv" v ;:u-"' {JH + 87)/ s t:J7) "" 551 /"'st .c::__, 4 {_:st1t!"oo) L'J,,/GR-f-/A/11/, ~ ;a A-1!--{ jL +"-J 3G :C :::-I J 1 (, N-)"' (3. ~c,.,_ ,;.c. )[t-z-);; -::. ·::, L_-z}/#t1-";h7~>') ;. C. c.- -· · I J:>rJPN.J r ·-· __ ._JJ,------.. ·--------.. ·-·--------------·-----L-------------------------------------------·-·······'--·----·------------------.. --- ,. 1 ::;, ? )t ;-z__, 6 I :5:>1 -:-7' 'S 7 /IV I £" .,_. Z/Z-, I !f'J {__ bt:AAII FPL-L-'/ -5(1/'r'«'l'&--/GE.G vi'\J C-e>r-JC-, Gt-A& ?IJG<:-Ic--~"'--.c.IPTI/'J.t, ) 5/',AN "' L /v'--<"" ~ -3 ~ '' ::. ;;1..-e:, §6"--l;,~z.' N ~ 6 ('. ~ ) +-,;;{9 ') -1-{ 1f" lfH1. I) (";_8C-+1.14 ') +-IZ,£," Z-f-t--/"<-1'- .?-!Jtd--,1;.-~b;tJ/. fVl,:. AJt /'e. ""' -vt--z-Ot-7-z--)/e,:: 415s P&-lfs ~-::-f.li/f>"' 4156C.nt·)/7.37"' .?17?-G/"':51 .e::::,tt:i3t1M-"'-l C-IJ G,c.-/C-::;fJfb4 IZ---~V-:-11/dt: ==' Z-4z.{J[,?'Z-/p)/t.(tt,Z.3.") ~ /,<J'Z6p51 <,4C3t.ltf.P& J ?/-1<=-c-IL--/)&f'C..!3;c(/ p /\) 4 3 II 4 = -;:;AJf!. 4 ::: 5t:..uz--){1/,7z.-) Dz-) ·"' o,!?' -~ £/;;-77 3"8'4€..J:: 31T4(z.J/;!Jo;oh:!) =·I Ct'..?xb,Z--1 >'x "'4·38!/11"' r,_ "-/3,1//J 4 {_ t3&1V! ;:::"'"'""' y 5!/P/'"".e-re6 ,.,.; e-,.-Je-. GL-A& , ?l-1-s.:::-k __ • F#'l'Z---C-1 rT/r-l,t; ) ::;.P/->r.J"' C 1-z--'--a")-3.%1 '"' II'-~""'-11-7~' PtJ "'(l6a .;.M-1-4.1 _j{3-6~ 'j --~"b,:z--+-/,c.· ~ /6iPI""'-r G L/IAis<-, ?!Jbf::--e.-bb"Jl>!Nj:, !'1---leo Llt-7z-)/6"' 31 ;::;9/ ~t--/b-s, -Pe,, 1>-1/-s"' 34910-t--'J/1·36" b,1bo r-s' <.t.C 3t.f"'"'") c:;.4Ec.tz-Sf-/t;;A;z.._;. !&~-; . p11 " V/oit-"' !f5o{Jf,7r-ft..Vc,.ca.z,.,;;) ""67.9/'SIL.,-f{z?1 M.t?) C-fJG."'-'1-L--bG;::v:=c-TitJN LJ"' ~Nfl 4 s 5LI6o){lt.;>z.)4{/-z-)s:;; a>·Z--.9"-:-J./£_jy 3'3'fe.J:. 31f4-{ -z.J/tJ.t?tJ1oM) n, 1 , ,' I FJ . · . · · 1 t,urf)rJr ~-----T·-·---------------------------------............ ·------+-----------·-- I I ;;,f/"'i::>"''f,::JtV 6£S/4 A) LoAG,S L-itlE: WAO'S " -/3(JP) /'2--"- : if> CJ J{.J z-) -:v-"' ~ t:-(9') {_;o) z-"' J?o I z_:J.:, /tJC,O /£r:uJ,r--=> G.<>t;/);z--::: &>ooo _Fu.PI'l--"' 15-co ().33 );;, 3& = /5 BG~ z-1,&5& !<>-;;, 1 r:~,P/£. ~ /& ( 10) ;-z- -§;:( GG <.... -§;tc--16 "' rz-oo ~ !5-!}.o c,., o& c; /.bs I f ~[ {_G,p+-6){~ )+ (zct+-Z-4:<-\ ';; -r/-z-5t-/C-z-)15a]j1 = /.357rs,c~/5<>J. A:>CM'"' J "'§,ot?tobh ""t7,tJN6 [! ... ) z.4 "',5:;:.1/V-z-< -t-C,-z-'Ji 1 L;;-4 /. // 6/J£?-!L-v 71"'--u/'-J?'/C-GTEE -Gh<'!S t.._.r"'"-/"&A '15(...A8 77-J/,:....~GSS P.tJ&-!.Nll. uN"-, ,C~;z.s ""rJ h/&A-CJt:.' J p ~ ~ Z-Gt?# ;"5/ I /d:-"" Z:&L? [AV,;', St>n.-\ 1 foC7'&'/Z.--cr SAF/!;TY ~ Z- ~-::.. Ptz./£:5," .J/P'<.../z.-""' J /zG.,;/z-"'Z-2-6 rst /JL.UNA6t-l!f" L&;a!Js ::; c:-,/:v::s ft / h ~ =' c;; IZ-~ {z-zG) l (....(2<"') "' Ys:r /.6s > .s;ce, C-3-) 1-s.~ "' 771 ---~~--!------------------------------···---------··'-· ........................................... ----........... ---....... . Lt:,J'/i.lbAL.-DE:S!,t,tJ I /£...-"'"' "" ;.hn--T!-1 /s,;v(l-1 ;:;;""c-"' ~ 5tE '~MIL-,; d, ,!1,?6 { /t..ct>?>P -1-/Z-~L---1-AJ:.::,___ ~ J ""tJ,t:JC-B { Jt:-&f-£-:,:'"'..,.... 20:..::'"-+ z.(~:\ ) -:; a.&c.8 [ :>t-78) ~ u/ //,,; ~-z--sr<--r- . AI, ;J c. ·::-/.J, z. {_ ~ +, 5) "" J c. rt:..;:: ..,__ C6rJ .. m-<>'-s ~------..~.~ I ......_}. ..!...::::__!" , ____.1 I f'ut-J N 1 k..t16f / IVG.ST ~&--..::.65 ::5G-IS/l"!;C-,. ,r;.o<>t;,{_:sc7s) '-'24/lb-s "'- w-i-"' s I :'?LJr;::..&n---;:7;~s /l}t!i&-T/-1 / S.?Vr!~ "' '7? {!.<> 'J/:t-CJ,_) :::-f?;"'LF ~t/;:.Je:,s-r"' j-c.(;z..-)/;z...u-9)-c Sb,t=L-F ,c__!Jr;::_?tL-,;,(Jc:An---NAIL-!~?; /"~a:-,4/-',.o. ~~~ ~cr/t--T "'l:s& j\JGit-·Z?:i: .. _L _-u;:.r;..; M~-r:A-s,;'I}/'/L-6 [,r;e;e"r 1-;h") Ar?/1"'~ /"~ ,&:-LY~ =-/t:-5'"' {.!f,o&S) ~ =-4-3 /bs V4(" =-4-3L/, :s) <::;, t; )b) ,c;!J ""/GJ-/"'L:--r > -ft:-f =>6 C-(JG=/<!..-C:.IJ,::;A::-bS N-<'/Z-f'J-1 / L,!frJIIJ ~ /4<?1://r-/'JT ""'a~£/.'.:> "'Jt:.L/&)/8 -,:;jz,;o .Pf-/6-s r't..-A_.-JtG i:r!Z6:>s <> lt1/L:; ..,· /vPo//z--"' /,tJ.r-16>.s -f&vsMN <f C..?rr?/"~/"'/1.) £,4ST / .NGS./': jt//..0/VftEr.J[::: ..J-&0-z-':;'/e "' /7Z-<:J jJ£--/6>5 yC./iN,?.G-::0:'/Juf.:f>S ~ (7z.&/e> ::> /73 /bs [lENS/oN -'f C&M/-'a-6,S/CJN ?/-../.:?n--1::::. -z..-X-4 ~r /'>?ATG-1 GNTt.J~N /7~ -srv..t:J / !::; ::.. 4 75 . 7_&tlsMI'IJ ""'1-=>t:s-5 )t':-f7s );,,;;; "'31J,J-o ,{,:s >/P<P :1 17..::, f~--/d ;:.. 4-l>/3-6 -:;, /3-7 hG "" f:;;a: E: '/ C:l '-/d 'j ._ = C· 3-c!/4-tfq A:M ) ftn, 7) ..._ "' z., z-.;;~ h-c/li:-"' '::: .z,z..-3'!:,/JI7£.~/..4)"' /,>f-.3. c::..;o =[ { 1-r f-4-3 ) / .z-c,e. )j _,r-z.-;-.5-', )-... ---~.-, 1-:>,/,-,-.!::.-"'.17, M C::..<?IY11"',.z.f!,;;5 ;,"-v "'/.5C3-5)cf7G" ),;&"' ::. f,tJ&7 ->-M<" :f 17?:, "fP,r-j??AILE-~"'-1?-E ALL--AJ--" a.-.s ,No 5r"--' c-e- I I I I \ L-/ I -b-.:-z t 111 << sr; Ll/'6/"' -:..,r;'LI ["•wv--zN'/ J -; tv<"l>>::m'vfvr<v-? I s:5'; -z•;'u -= .'5:1" s:?7'S!Y_t ?5'/fl ~-.::1 I ""'"'..7 ~ !i?<?'i'~_,·. ?f-= --4/o7/ I £->.-z fs //1 << S.ff 719 10 " \ t?V'<7/SS'/( 99 '.7 [ 9Z' \""<7-"'Z:i>//' J ;: <Vd'!i(V? .f., I I I [V<?/SS?Vd~ F (VP/Sf\/'?.1-:S<;;>/ 6$. 2.-;: 9/ 9t?6 I ""' S.5?.??.L5 ;;WfVrr?;f j '><t/-i!if 9'p6/--9/z(""'I.J '-'??/-:::. Jtv9!A'v-t4/ ~ J.s::;N/.J..st;t'3 rt"'l~dtM?? f' rv?;,;-~_t "'9'1 1 ll = --z.; / s-z.21 "" II'/ w = >::>?d./.5: -'3 7rv"'7 d j 'ryy-7~ s-zs;-= '¥/-,.\,7/7'71?/-=. "?/-,..?tv "" lfV?Ifli"'W : f-1./.ll<"o/H..t-z!d'(l/ ! . . . . s: 'V-zYI? !1? ---'7/?9 r/'7 I L . 1 1>7 ""s v '"" d7d c;.+£ "' (:::A.?'!?? Q-z ~ ).,pp-;:/ / 7?7/t?::f >, 7!?? "'(17?'£/1_ <?t?/?197} (9·?7( ;;r-z") \ .P'?'Z';J <: -7-;>j 7-<£/S'Q_::IS:f-Q/7/ ~ 23: 1 <:;;/7!~ .f,,Jf r/PrW <>'7i?(Vrv'Vr/7 1, <;;; ?./. s:. ;<. .z y rt/.J.>?<>'<;i -:?1'7?f17 . r-:tfs:+ < .:!?dt?c/""' .C'i?' (""/\ -:>'1}\ s·l} :P'/':i ".,;,_/1 f·;;;; --'f( t!Ct?'/ <7;;;<7/ "'-"""f'l"'::Y"'~ I -.:yp,,'j?..tr:/ C.tr-z X f· ,{tft::>'_.J S-?lr:/(1/ ).9ij-t?(J(/ y <67/.:;tJ- 9>?/,., _1_,"'./:?;?J'/ f7?"'?."~ Vd/7 ---;;,t;?~ :i't-N71f7'(1/ --u f7'9!7'5 77·:r;il/t--? I $ I F'-t ;r I (' ('lrrlcf I I 'I I ~l------1 I ~- Ql f t ~·~.., "' 1 i f ji ·I --" ~ ~ '11 o;l?d !?'? s '-"''7"/(.z;;; 7<?/ "" .ls9M/_L9v:;Y ::/?./9y "'-\_--zt72/\_?I/1'P/--. ft,L/?V';?-/tf_i:?/>'(1/ ·. S'?/'7<'~ --'?IT1'9rf7 ;;1--:>./{.p s 9 11' 999 "'\"'1 2 /'?) 9'77't?:;;: -?!1/'1919'7 S:'3~'Y Js·?N/J$r/3 ' L-0: I .J ·--·--------·----.L .. _. ________________ ,~ ... ·-··--· --------------------_____ L .... ----------·------~--.. ----· ,_ .... _. ........... -... ·----------.. !--"'·-----------·- w r<-'<-('; {. ::) 12- pVf\J "' .? L-9') 1-z-· "" 4 &0 ,. &-ft:. I I Z--1'; I~ ?, ~-=> IIZA5 (;z..-/..-) :::. ;,,;7 .> ;,5 415t?Cf) /'}'z.PIIl/)6 /Jp;;.[JI);VN S 1/2-A/"'S @ C-NZ-!VG./Z .• -5 :f ba.nt-JAME>S , SIMI".5t>fV ~/'lib If? LIP) j/Jo/.)i 14.-Pn.-.&.{1/!JL //G/t-(!) f"' C.."-;'SP/5 (_J) /{,;,t :;,-,If>)"' ,;'ct:,/6$ L)f?c-5 /"tG.Iz-@ 7"? "'17z.C9"J/C3-14-,IGJ ~G16(6sL/5<>5 J& L.!Pjv) 46 0 !h.,.,_---'{.---;,__----, I z.! l j, /' J?{tz/r) 57.?&s~~·r-------~ ! I I /'at?i/1/:,t; /Jct:./}tMJN 671.?1'11"'& f!! w~$ 61MP6&FNflpAI16 f!: (!<>) /tJtl x !?,_",,_..GpML -, ~j J r i ~~----~-I } --· J I 1'-::.C-"' 57t'dcYJ/!o"'" £19 !b-_:, L:/545, 6/JGNZ-I?:,<.<;;..TS J{'f /tGt(1 /,) ~ (.575 rt 3? )/z.-et;.{),t) ::: z.t-< !tJC,,..'J/;;;.-::-.!!:> ..,. ?,l.J/Eb/L--Gfl64/t--;tlAii>INA /"G4-,4P,A /:t.GSGA/Jht.-1-f ~""/Z-'1 /S6 #6-zP, /J/1<7-FAS.T ;t/A;L-S (,t?o~ ''<( >C ;?.;") V-l .? """~ _r'"' f:::. 6 ~ = /M5<J ~-tf,s.~ )-~ -"" 41, tb t/,<'1[>"' 4-t,?C:!-t>)c'.;,.?)c'.z-) ,s9 "'/54r""-F= >58 I I I i COM check Software Version 3.4.2 Envelope Compliance Certificate 20031ECC Report Date: 0411 1108 Data filename: Untitled.cck Section 1 : Project Information Project Title: Construction Site: Owner I Agent: Designer/Contractor: Section 2: General Information Building Location {for weather data): Climate Zone: Heating Degree Days (base 65 degrees F): Cooling Degree Days (base 65 degrees F): Project Type: Vertical Glazing I Wall Area Pet.: ActivitY Type(s) ~rz-M>l3:. Climate-Specific Requirements: Nederland, Colorado 13b 5554 649 New Construction 0% Floor Area JW 1"2..0 Component Name/Description Gross Area or Perimeter Roof 1: AII~Wood JoisVRafter;Truss 120 Exterior Wall1 : Wood Frame, Any Spacing 396 Door 1: Solid 24 Floor 1: AII~Wood Joistrrruss 120 Cavity Cont. R-Value R-Value 19.0 ~ 1 1.0 ~ 5.7 (;:0"" (a) BUdget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: Proposed U-Factor 0.027 0.051 0.070 0.074 Budget U-Factor 0.061 0.092 0.145 0.057 0 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's Installation instructions. 0 2. Windows, doors, and skylights certified as meeting leakage requirements. 0 3. Component A-values & U-factors labeled as certified. 0 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated A-value without compressing the insulation. 0 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. Q 6. Cargo doors and loading dock doors are weather sealed. 0 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii} Installed inside an appropriate air-tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. · 0 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Page 1 of 9 Doors that open directly from a space less than 3000 sq. ft. in area. Q 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.2 and to comply with them atory requirements in the Requirements Checklist. CoNNie. ~ubN~"iN ,nnt..-u-1/t'5 / v~ Name ~ Title Date Page 2 of 9 COMcheck Software Version 3.4.2 Lighting Compliance Certificate 20031ECC Report Date: 04111/08 Data filename: Untitled.cck Section 1: Project Information Project Title: Construction Site: Owner/Agent: Section 2: General Information Building Use Description by: Project Type: Activity Typ.!!(§) Other Activity Type New Construction Section 3: Requirements Checklist Interior lighting: Floor Area 100 0 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts . Complies 100 100 YES Q 2. Exit signs 5 Watts or less per side. Exterior lighting: 0 3. Efficacy greater than 45 lumens!W. Exceptions: Designer/Contractor: · Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low~voltage landscape lighting. Controls, Switching, and Wiring: 0 4. Independent controls tor each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stalrways or corridors that are elements of the means of egress. 0 5. Master switch at entry to hotel/mote! guest room. 0 6. Individual dwelling units separately metered. 0 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant~sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; AreaS that use less than 0.6 Watts/sq. ft. Q 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. Page 3 of 9 . 0 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. 0 1 O.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: Electrnnic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design repre~ented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in COMcheckVersion 3.4.2 and to comply •th the mandatory re irements in the Requirements Checklist. {1iitJie -~h,..jSoJJ nZ... l~ 4/t5/o?: Name ~ Title Signature Date Page 4 of 9 COM check Software Version 3.4.2 Lighting Application Worksheet 20031ECC Report Date: Data filename: Untitled.cck Section 1 : Allowed Lighting Power Calculation A B Area Category Floor Area (112) Other 100 Section 2: Actual Lighting Power Calculation A Fixture ID : Description I Lamp I Wattage Per Lamp I Ballast c Allowed Watts 1112 1 Total Allowed Watts = B c D Allowed Watts (8 X C) 100 100 D E (CXD) ~~~~ 2 2 50 100 Total Actual Watts = 1 oo Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 1 oo Total Actual Watts = 1 oo Project Compliance = 0 Page 5 of 9 COM check Software Version 3.4.2 Mechanical Compliance Certificate 20031ECC Report Date: 04111108 Data filename: Untitled.cck Section 1 : Project Information Project Title: Construction Site: Owner/Agent: Section 2: General Information Building location (for weather data): Climate Zone: Heating Degree Days (base 65 degrees F): Cooling Degree Days (base 65 degrees F): Project Type: Nederland, Colorado 13b 5554 649 New Construction Section 3: Mechanical Systems List ~2m Type & Description Designer/Contractor: Quantity 1 HVAC System 1: Heating: Other, Electric I Cooling: Other. Capacity <54 kBtu/h, Evaporatively Cooled Condenser I Single Zone Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : None Generic Requirements: Must be met by all systems to which the requirement is applicable: 0 1. Load calculations per 2001 ASH RAE Fundamentals Q 2. Plant equipment and system capacity no greater than needed to meet loads • Exception: Standby equipment automatically off when primary system is operating -Exception: Multiple units controlled to sequence operation as a function of load (J 3. Minimum one temperature control device per system Cl 4. Minimum one humidity control device per installed humidification/dehumidification system 0 5. Thermostatic controls has 5 degrees F deadband ~ Exception: Thermostats requiring manual changeover between heating and cooling 0 6. Automatic Controls: Setback to 55 degrees F (heat) and 85 degrees F (cool): 7-day clock, 2-hour occupant override, 1 0-hour backup ~ Exception: Continuously operating zones ~ Exception: 2 kW demand or less, submit calculations 0 7. Automatic shut·off dampers on exhaust systems and supply systems with airflow >3,000 cfm 0 8. Outside·air source for ventilation: system capable of reducing OSA to required minimum 0 9. R~S supply and return air duct insulation in unconditioned spaces R·S supply and return air duct insulation outside the building R-8 Insulation between ducts and the building exterior when ducts are part of a building assembly Exception: Ducts located within equipment • Exception: Ducts with interior and exterior temperature difference not exceeding 15 degrees F. Page 6 of 9 0 10.Ducts sealed~ longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 1818 tapes and mastics ~ Exception: Continuously welded and locking~type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification 0 11.Mechanical fasteners and sealants used to connect ducts and air distribution equipment Q 12. Operation and maintenance manual provided to building owner 0 13.8alancing devices provided in accordance with IMC 603.15 Q 14. Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COM check Version 3.4.2 and to~o ply with the mandatory requirements in the Requirements Co1JtJ,e.~Jbr\S6q '!JFJ~ .qfgs/O'?: Checklist. qL Name ~ Title Signature Date Page 7 of 9 20031ECC Report Date: Data filename: Untitled.cck COM check Software Version 3.4.2 Mechanical Requirements Description The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 : None Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automat.ically controlled to be off when the primary equipment and/or system is operating. Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Thermostats controlling both heating and cooling must be capable of maintaining a 5 degrees F deadband (a range of temperature where no heating or cooling is l?rovided). -Exception: Deadband capability is not required if the thermostat does not have automatic changeover capability between heating and cooling. 6. The system or zone control must be a programmable thermostat or other automatlc.Control meeting the following criteria:a) capable of setting back temperature to 55 degreeS F during heating and setting up to 85 degrees F during coolingb) capable. of automatically setting back or shutting down systems during unoccupied hours using 7 different day schedulesc) have an accessible 2-hour occupant overrided) have a battery back-up capable of maintaining programmed setllngs for at least 1 o hours without power. Exception: A setback or shutoff control is not required on thermostats that control systems serving areas that operate continuously. Exception: A setback or shutoff control is not required on systems with total energy demand of 2 kW (6,826 Btu/h) or less. 7. Outdoor~air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 8. The system must supply outside venti!atior, air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor-air quantities exceeding minimum required levels, the system must be capable of reducing outdoor-air flow to the minimum required levels. 9. Air ducts must be insulated to the following levels:a) Supply and return air ducts for conditioned air located in unconditioned spaces (spaces neither heated nor cooled) must be insulated with a minimum of R~5. Unconditioned spaces include attics, crawl spaces, unheated basements, and unheated garages.b) Supply and return air ducts and plenums must be insulated to a minimum of A·B when located outside the bui!ding.c) When ducts are located within exterior components (e.g., floors or roofs), minimum R·8 insulation is required only between the duct and the building exterior. Exception: Duct insulation is not required on ducts located within equipment. Exception: Duct insulation is not required when the design temperature difference between the interior and exterior of the duct or plenum does not exceed 15 degrees F. 10. AU joints, longitudinal and transverse seams, and connections in ductwork must be securely sealed using weldments; mechanical fasteners with seals, gaskets, or mastics; mesh and mastic sealing systems; or tapes. Tapes and mastics must be listed and labeled in accordance with UL 181A or Ul1818. Exception: Continuously welded and locking~type longitudinal joints and seams on ducts operating at static pressures less than 2 inches w.g. pressure classification. 11. Mechanical fasteners and seals, mastics, or gaskets must be used when connecting ducts to fans and other air distribution equipment, including multiple-zone terminal units. Page 8 of 9 12. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity (input and output) and required maintenance. actionsb) equipment operation and maintenance manua!sc) HVAC ·system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired or field~determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming commentsd) complete narrative of how each system is intended to operate. 13. Each supply air outlet or diffuser and each zone terminal device (such as VAV or mixing box) must have its own balancing device. Acceptable balancing devices include adjustable dampers located within the ductwork, terminal devices, and supply air diffusers. 14. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and exhaust hoods, vents, and ventilators must be equipped with motorized dampers that will automatically shut when the spaces served are not in use. Exceptions: • Gravity (nonwmotorized) dampers are acceptable in bUildings less than three stories in height above grade.-Ventilation systems serving unconditioned spaces. Page 9 of 9 I I I ' 1 I ' I I I I I i. ' "I I , I ' J " I z 0 ;::: "' > w -" '·" et: "' l!J 0: 'I I I z , ·lo " -q' ' 1- -~ , I~ w ," It I':J "J " I f-• • I " I"' I I I I I I. PROPOSED SKINNER RIDGE CENTRAL COMPRESSION FACILITIES SECTION 36, T5S, R98W, 6TH PM NW CORNER SEC110N ~6, l5S. R98W 1924 GLO BRASS CAP W 1/4 CORNER SECTION 36, T5S, R98W ;_ FOUND STONE W/POST LEGAL OESCRIP110N: CHEVRON PROPERTY I ) A PARCEL OF LAND SITUATE IN TRACTS 103 AND 104 LOCATED IN THE NW 1/4 OF SECTION 36, TOWNSHIP 5 SOUTH, RANGE 98 WEST OF THE 6TH PRINCIPAL MERIDIAN, COUNTY OF GARFIELD, STATE OF COLORADO, nlE PERIMETER BEING MORE PARTICULARLY DESCRIBED FOR AREA AS FOLLOWS: I I I COMMENCING AT A FOUND STONE IN PLACE FOR THE W 1/4 CORNER OF SAID SECTION 36, WHENCE A FOUND 1924 GLO BRASS CAP IN PLACE FOR THE NORTHWEST CORNER OF SA!D SECTION 36 BEARS N00'04'39"W A DISTANCE OF 2643.38 FEET, WITH ALL BEARINGS CONTAINED HEREIN BEING RELATIVE THERETO: THENCE N16'38'57~E A biSTANCE OF 213.19' FEET TO THE TRUE POINT OF BEGINNING OF THE PARCEL DESCRIBED HEREIN; lHENCE N68'48'53"E A DISTANCE OF 740.33 FEET: THENCE S25'11'JO"E A DISTANCE OF 507.55 FEET; THENCE S55'02'39"W A DISTANCE OF 887.02 FEET; THENCE N14'22'17"W A DISTANCE OF 722.56 TO THE POINT OF BEGINNING, CONTAINING 11.19 ACRES MORE OR LESS.· NOTES: 1) THE PROPOSED SITE AS SHOWN AND DESCRIBED ABOVE IS NOT A BOUNDARY SURVEY AND NO MONUMENTS WERE SET, THE PURPOSE OF THE ABOVE LEGAL DESCRIPTION WAS TO DESCRIBE THE PERIMETER AND AREA WITHIN CHEVRON PROPERTY FOR THE PROPOSED SKINNER RIDGE CEN1RAL COMPRESSION FACILITY. 2) THE CENTRAL FACIUTIES EQUIPMENT ARRANGEMENT AS SHOWN ABOVE WAS PREPARED BY URS -WASHINGTON DIVISION PER PLAN PBSR-59536AVF-CIV-LAY-URS-00000-00005-00, REV 0, DATED APRIL 22, 2008. APPI~OVED SUBJECI' TO NOTED EXCEPTIONS & INSPECTIONS GARFIELD com;TY &U!LDING DEPARTMENT Dot> Vz:t?M_ By k H :> FIELD COPY •s 0 .NO INSPECTION WfTHOU1 Mis-~-"iiiial~~~--~T' TIIESE PLANS ON SITii'. GRAPHIC SCALE !N FEET page of 1 INCH ~ 150 fll:T SURVEYOR'S CERTIFICATE I, George R. Bauer: a Professional Land Surveyor in the Slate of Colorado do hereby cerUfy thot this Survey was mode under my direct supervision, on · · represents said Survey. COLORADO P.l.S. 27925 F"REF"ARtlD !"OR, CH5VRON U.&.A. INC. CONE>TRUCTION OURVI:Yo, INC. OIZ>IZ I>UNRIE>!ii 6L.VD. PBSR-59836A VF-CIV -SRV -CSI -00000-00001-U02 1>11.. T, CO B>li!>S:I DRAWN BY: 8LM CHECKED BY: GRB DW<l:CKEVRON C€N1RAL-fAClL11ES ( 10!1>1i!>·S1S:> 0ATE:04/29/08 SCALE: 1" = 150' SHEET: 1 OF 1 . 0 I Q !. W"t<O<OCOIU•t~S' nsst-ii!l ... Vl'-(1<-IU·!.A'H'(IOOG·OO:lCl"-01:1 11~1111 W.!i£ Pl."'· loP>ItOiflU<r.CIUi1fl.(lt!WIS>I<IWII"'~~~tl-ot. J,CCJilo.<tl!llto.•JJ.• Ul$1. CEJ<lW!S • I' OEIIQ< tt><!Wl$ • 1' t. PJ.I Pl!'l: ut1 10 & U<UJ.U(O .StU II<( atlll>"JJ. !r JJ.I. ctmTRUC:llll< lUI>OW lUIW<~IOOCflliH ~. o:{Jil"-'l:TIIl S>U.I,I. OifC. JJ.L U!SfUO:: toollHl•S..., fl(l.~ '"''" JJ.l O!S! .. <1:0>!<1 .. 1!$ i>(l !<UIT!M ""IG! fO W!ST...:l!EJ<. ~~' 11•Pi • ~Of£U ~· , f Sf' M><:ICon~JnaM / •.oos><<> saw cno~<"O<'> ,..,...,..., t.m<>rleo E~P'"""~'on """' P.-wuc•<on 0 c B Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information Assessorffi.e_asurer Property Search I A~sessor Sub1>et QJJ~r)' I Assessm Sales_Bearch Cle_rk &_Recorder RecJl)tion._Search ParceLDetail I Yalue D.etail I SalesJ)etail I Residen.tial!C.Q.mmer.cial ImiKovement Detail .Land D~tail I photo.gmplls I Mill Leyy: Re~nuesDetail I Tax Area II Account Number II Parcel Number II 2008 Mill Levy I I o29 II R29o444 II 2139163ooo14 II 32.108 I Owner Name and Mailing Address jCHEVRON USA INC jC/0 CHEVRON TEXACO PROPERTY TAX IPOBOX285 jHOUSTON, TX 77001 Assessor's Parcel Description (Not to be used as a legal description) jSECT,TWN,RNG:16-5-98 DESC: SEC.7: jTHATPTOFLOTS 12,14ANDNESENE IL YING DESC: BELOW THE ESCARPMENT j(NET 14.20AC) ALSO THAT PT OF DESC: jTRS. 50,51 AND 56 LYING BELOW THE jESCARPMENT (NET DESC: 175.17). jSEC.8: THAT PT OF LOTS 2,4,7,8, jSWNE, NW, DESC: N1/2SW, Wl/2SE, jL YING BELOW THE ESCARPMENT (NET jDESC: 222.84AC). SEC.17: THAT PT OT ILOTS 1(23.162, 3( DESC: 8.57), 14(8.60), 5(11.84), 6(15.00), 17(13.64), DESC: (80.81 TOTAL 173.0 jNET) LYING BELOW THE ESCARPMENT http:/ /www.garcoact.com/assessor/parcel.asp?Parce!Number=213 916300014 I I I I I I I I I I I I I I I I I I 1128/2009 Parcel Detail Page 2 of4 IDESC: ALL OF TRACKS 80(160 AC), I 1110(110 AC), 111(160 AC) DESC: AND I ITHOSE PARTS OF THE FOLLOWING IRS I IL YlNG BELOW DESC: THE ESCARPMENT, I ITRS. 57(117), 60(35), 62( 46), 84( I IDESC: 118), 83(80), 81(120), I 182(24), 87(46), 79(73), 88( DESC: I 145), 90(58), 77(103), 91(53), I 176(118), 75(116), DESC: 92(52}, I 193(76), 94(121), 113(121), I 1112(137), DESC: 6-98 TR. 41(160), I jAND THAT PART OF TR. 109(106), I IDESC: LYING BELOW THE ESCARPMENT I jAKA: LUCKY STRIKE #9 DESC: GLEN I IBEULAH, GEN. JOFFRE #3 & 4 AND I jTHOSE PARTS OF DESC: THE FOLLOWING I IL YlNG BELOW THE ESCARPMENT: GEN. I IDESC: JOFFRE 2,5-14, LUCKY STRIKE I 14-8, 10-14, AND GEN. DESC: PERSHING I 11 & 2. SUC:R290037 BK:0472 PG:0361 I IBK:0445 PG:0360 BK: 1655 PO: 178 I IRECPT:666845 BK:0858 PG:0942 I Location I Physical Address: IITWN 5 ROE 98 SEC 16 I I Subdivision: I I Land Acres: 112840.21 I I Land Sq Ft: jlo I Section II Township II Range I I 16 II 5 II 98 I 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 60,3ooll 17,4901 I lmJ2rovements: )I oJI 0 I Total: II 60,3ooll 17,4901 http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=213 916300014 1128/2009 Parcel Detail Most Recent Sale I I Sale Date: I l=J =======s~al~e ==Pr=ic=e~: I Basic Building Characteristics Number of Residential 0 Buildings: I Number of Commllndl 0 Buildings: No Building Records Found Tax Information I Tax Year II Transaction Type I 2008 II Tax Amount I 2007 II Tax Payment: Second Half I 2007 II Tax Payment: First Half I 2007 II Tax Amount I 2006 II Tax Payment: Second Half I 2006 II Tax Payment: First Half I 2006 II Tax Amount I 2005 II Tax Payment: Second Half I 2005 II Tax Payment: First Half I 2005 II Tax Amount I 2004 II Tax Payment: Second Half I 2004 II Tax Payment: First Half I 2004 II Tax Amount I 2003 II Tax Payment: Second Half I 2003 II Tax Payment: First Half I 2003 II Tax Amount I 2002 II Tax Payment: Second Half I 2002 II Tax Payment: First Half I 2002 II Tax Amount I 2001 II Tax Payment: Whole II Amount I II $561.561 II ($252.46)1 II ($252.46)1 II $504.92! II ($236.20)1 II ($236.20)1 II $472.401 II ($300.99)1 II ($300.99)1 II $601.981 II ($343.98)1 II ($343.98)1 II $687.961 II ($420.50)1 II ($420.50)1 II $841.001 II ($422.10)1 II ($422.10)1 II $844.201 II ($837.02)1 http://www.garcoact.com/assessor/parcel.asp?Parce1Number=213 916300014 Page 3 of4 1/28/2009 Parcel Detail 2001 II Tax Amount II $837.02j\ 2000 II Tax Payment: Whole II ($871.96)1 2000 II Tax Amount II $871.961 1999 II Tax Payment: Whole II ($1,080.26)1 I 1999 II Tax Amount II $1,080.261 Iop_pfPage AssessoLDatab!!s~_SearchDptions I T reasurer,_Database _Search_Qptions Clerk &_Recorder_Databalle SeiJI.ch Options Page 4 of4 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However, Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright © 2005 -2008 Good Turns Software. All Rights Reserved. Database & Web Design by .Good Ill.IJ1S SofJ_y,rar_e. http:/ /www.garcoact.com/assessor/parcel.asp?Parce1Nurnber=213 916300014 1/28/2009