Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Offlce:970·945·8212 Fax: 970·384-3470 Inspection Line: 970-384·5003 Building Permit No. Parcel No: Locality: Elk Creek Dev. Block Lot 9 Job Address: Use of Building: __ _:ca:.:cd~.ition to living room on crwsp & cov .. ~a::::ti.:.o __ Owner: Contractor: owner Fees: Plan Check: $ Septic: Bldg Permit: $ 335.25 Other Fees: Total Fees: $ 553.16 Clerk: Date: I 1 2 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 8'" Street, Suite401, Glenwood Springs, Co 81601 Phone: 970-945-8212 I Fax: 970-384--3470 I Inspection Line: 970-384-5003 www.garfield-countv.com Parcel No: (this infonnation is available at the assessors office 970~945~9134) ~~~'5;:-).SIOI.o 009 Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description nll!<1 Jlnr.rl. • ~-fle.LD a:."s.tlt Qo B/(oL!r .. ---t 3 Lot No: q Block No: f.(J Subd./ ExEJtion: ,i-~ · c. !<. 6-u ... t.-1.< tA..-1::> d-lvi-:::, lo)') 4 &;ner: (propc owner) ohV" D!..AC\ lO.S Mailing A~:s: ()I ) .)(£ o\4'1 ~12.. 1r. 1-(<tiJ Jk_ '1'6LI-3~'l8 AltP~ q <t-o 139 5 contracerw n.e-r Mailing Address: Fh: AltPh: 6 :fbi~ Engineer: • e;, Du..tA SVY\OY':O,O(I Mailtg Addresr ( I U.:; • (D h , S.urF-Z.<.:Xl 6LC>'::> Ph: "'fL~:) ... I D Ql~ AltPh: 7 Sq. Ft. of Building? Sq{~ or,p;~'J'L2Jl Height: No. of Floors: I 8 Use of Building: Mcl-l-lion -ro l !Zoom~ f'v.. Jf.c A" . . Uvlnq v-~ .IJJ:ii. 9 Describe Work: AticJ.l -lion I • 10 Class of Work: . oNew o Alteration 1\l Addition 11 Garage: Septic: 11\.tA. o Attached 0 Detached o ISDS o Community 12 Driveway Permit: ~ Owners valuation of Work: $ NOTICE Authority, This application for a Building Pennit must be signed by the Owner of the property, described above, or an authorized agent. If the signature below is not that of the Owner, a separate Jetter of authority, signed by the Owner, must be provided with this Application, Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate pennits may be required: (I) State Electrical Permit, (2) County ISDS Permit, (3) another permit required for usc on the property identified above, e,g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void PermiL A Building Perrnlt becomes null and void if the work authorized is not conunenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that tlle information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, 1 agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable Jaw. Review of this Application, including submittals, and inspections of the work by the Building Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local Jaws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE NOTICE & CERTJFICA TION ABOVE: (l,;l. .»~ /_ •.. If /v-1 /Df O~ERS SIGNATURE#' DATE STAFF USE ONLY .::; ... Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fee: Manu home Fee: Mise Fees: ~~1-(:1. -:tei/..'1!~ zr1. cr 1 :$ ~. ~ ~~5'.2-::' ISDS Fee: Total Fees: Fees Paid: Balance Due:,S$'3. '(l BP No & Issue Date: ISDS No & Issued Date: ~~~.~ lqq_ll I t22K 2.13.< D'l .· ~:i'~ Setbacks: OCCGroup: Const Type: zA~: rfj 91A D B~EPT: ~ 1 P1;DEPT: ~~ 't I ~l$/Q~ g{(~~ ~~\~~ ~-~· APPRO J\L ' DATE APPROVAL'"'< ~ DATE I ' ' The following items are required by Garfield County for a final Inspection: 1( 1) A final Electrical Inspection from the Colorado State Electrical Inspector. ~~pY2) Permanent address assigned by Garfield County Building Department and posted at the v-· structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non~absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non~absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to alllBC and IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a C.O. for the building identified jn the Building Permit. ll /zit I o'i? DATE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date :_J~obn=Do=u:sg::::las:::._ ________ Subdivision _____________ Lot/Block _____________ Contractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Carport: Total Valuation Crawl Space Total Valuation Decks/ Patios Total Covered Open Valuation Type of Construction: Occupancy: Valuation Total Valuation 234 sq.ft sq.ft sq.lt sq.lt X $74.68 234 sq.ft sq.lt X $41.00 sq.lt X $33.68 sq.ltX $18.00 sq.lt X $12.00 234 sq.lt X $9.00 44 sq.lt X $24.00 sq.lt X $12.00 Commercial sf X sf X sf X sf X sf X sf X 17,475.12 0.00 0.00 2,106.00 1,056.00 0.00 20,637.12 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review tbis document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawri to scale. · 1 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. 1. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each corner of the proposed structure(s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the fmal plat with the proposed structure located within~ envelope. Yes. ___ _ 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a corner lot. Special setbacks do apply. Yes / 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? ~/\D.- Yes. ____ _ 4. Does the site plan indicate the location and direction of the County or private road accessing the property?. ~ Yes. ____ _ 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal govermnent or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies fi'\£Jv Yes ____ _ 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accor?ce with the IRC or per stamped engineered design? Yes _ _:_ __ _ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ./ No ____ _ 8. Do .the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes / No ----- 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes / 10. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction:_/ Yes ______ _ 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or rysts or trusses? Yes ______ _ 12. Does the building section drawing or other detail include the method of positive connection of all columns and _9-eams? Yes "' ------- 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes / 14. Does the plan include any stove or zero clearance fireplace plarmed for installation including make and model and Colorado Phase II certifications or phase II EPA certification? ~/\D.- Yes No. ________ _ 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? fl\.{)o... Yes. __________ No _________ __ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms andior basements comply with the requirements of the IRC? (!'\.{)-- Yes _____ _ 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilatio~r all habitable rooms? Yes. _____ _ 18, Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specifY safety glazing for these areas? Yes No ~ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? '/'A- Yes _____ _ 20. Do you understand that if you are building on a parcel of land created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? rf\0- Yes ____ __ 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation gr substantial modification of the plans. Yes ./ 22. Will this be the only residential structure on the parcel? Yes No Ifno-Explain: ______ _ 23. Have two (2) complete sets of construction drawings been submitted with the application? . Yes V 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes X 4 25. Have you designed or had this plan designed while considering building and other construction code requirements.? Yes / 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zone distri,__ Yes _______ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes / 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes ./ 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or "Septic System" fees required, at the time you pick up your building permit? Yes X 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30p.m. Monday through Friday. Inspections are to be called in to 384-5~03. Yes 1\ No _____ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspection fee? Yes. _ __.,_ __ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes )( 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes _ __,,_ __ _ 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes ____ ~~---------- 35. Are you aware, "that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes X 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? V'\0-- Yes ____ __ 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? ~ Yes ________ _ I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. a&-aa· SigKature of Own~ 11 /Z-L!/o'ir Date q~t.J-:e.:e.7B at __ 9...!...::..8-'4'---=e,c.:::3::_l'-"8"---_( evenings) Project Name:_.._A,_,clcle:=..::..!.i_,_f1_,_,· O"-'V''-'--'1c'-=--'L::.c1,_,V--'-1-'-n<j=T---'{?_o-=-""0-'-'YY''--------- 9 & 'l. -0 I b'J (days); Phone: Project Address: 0/4C\ Apo..cite Ov. ne-U) CO.S.+ie_, CD 6 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building pei:mits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. BpminreqDec2007 7 . GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snowload (measured at the roof): 40PSF up to 7000ft. elevation. 50PSF 7001 to 8000ft. 7 5PSF 8001 to 9000ft. 1 OOPSF 9001 to lOOOOft. Seismic design category: B Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R30 1.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 log construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • Basement wall R-values are R -10 befow grade, R-19 above grade. • Slab perimeter R-value and depth is R- 10/36in. • Crawl space wall R-values are R-10 below grade and R -19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceilinglfloor garage to house must have R-19. Take precautions to protect plumbing in these areas. Ken Smith From: Sent: To: Cc: Subject: Fred Jarman Thursday, February 12, 2009 8:01 AM inthewind5@sopris.net Ken Smith; Andy Schwaller House Addition Attachments: Fred Jarman. vcf Hello Beth, Page 1 of1 Thanks for meeting with me about your addition to your house at 0149 Apache Drive. It has been determined that you do not need to get a variance as the addition doers not appear to encroach into the side yard set back of 10 feet. I have instructed the Building Department to review the building permit. If you have any questions for me, feel free to call. If you have questions regarding the building permit, I would contact Ken Smith at our office. Thanks- Fred Fred A. Jarman, AICP Director, Building & Planning Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 970.945.8212 2/12/2009 ~ W~. ~~~. ~. Uv--z.oo ~ ~··· ~~C) OtJ ~ a_s<;.oc-~, ~ ~~ d'-. L0CAJ) Qd~ ~ }-Lf)CL.Cf.--(.J.;~ s:t~ 0LY~ J l::/1 - As ~\)L ~~ ~ ~~~ tfU..!\_. QA['1 si-~'v~ r\.--OGIA WO--.-Gl 0:. ~ OLAJ"-~ ~ G~~ ~ __t~ . c \ \)0~ (vves-v-~ V ~ tS g~ cz ~ ..:::<v' V'l. c.Jl y --\-k>-o_cl~ +i ~\..-. ttu't Cvu r~~~ ~ LD ecd::L\_Q.._G~ ~. 1cL~~\..Q.J:> -f-pO\ ~~~ · AL~ +tr-v'V'-~.. ~rs+&~ J-e-oo_()ll, ~G()J- ~t:h----~--_jot~ DlY~~ ~ L{-331 <t> -.Jvkt~ Cl-LLl -cr~ -ors q - ELK CREEK HOMEOWNERS ASSOCIATION GENERAL MEMBERSHJP MEETING OCTOBER 28, 2003 *Meeting was called to order at 7:15p.m. *Those present were:Jeanne Arnett, Melody Baker, Dan and Carrie Bowen, Linda Carson, Mike and Debbie Conn, Web Cross, Tim Curtiss, FC Dobbs, Jolm Douglas, Kaye Duskin, Nancy Enquist, Camarie Erickson, Joyce Gaston, Kevin Jochum, Sheryl Klima, Eileen Koch, Jim and Peggy Leonard, Dave andTiffany Lindenberg, Mike and Maureen Malloy, Greg and Leslie Nepp, Laurie O'Connor, Sarah Pagni, Patti Payne, Ron Reed, Susan Dardine, Debbie Smythe, and Ken Swartz. *A motion was made by Mike Malloy to accept the ininutes from the Spring General Membership meeting. · FC seconded the motion. Motion carried. A ininor addition to be made is to include the request for a second "Dead End" sign to be put up on the north end of Comanchero. · *Verification of proxies was made. 1. President's Report-Patti Payne a. A meeting was held by the Board of Directors and the residents of Apache to discuss the results of¢e road survey of Apache. After numerous discussions about how the road as it is currently ilsed is not in its proper location, it was concluded that no one is going to do anything about the results unless we have an issue. · b. High Rise Tree Service trimmed the trees along the roads. The Board felt that more work could have been done .. We did get reimbursed 50% of the cost by the· state. A vote by show of hands of the homeowners present on . whether to do more tree trimming in the year 2004 resulted in NO.· c. After discUssing the Boards attempts at getting lighting for our two entrance areas, Eileen Koch made a motion to put it to a vote as to whether we should continue to pursue this subject any further. Susan Dardine seconded the motion. Motion carried. The winning vote resulted in. the fact that the HOA will NOT put lighting at the two entrances to our subdivision. d. There has been an increase in vandalism throughout our neighborhood. Please be on the alert for anything suspicious. 2. · Vice President Report-Linda Carson, a. After a discussion on weeds. and the possibility of having noxious weeds sprayed along our roads, a vote was taken by those present with the result being: NO spraying of any weeds will take place in our subdivision. b. Wilbur Fix wanted to express his concern that when there is no longer water in Eric Williams' ditch property owners that border this ditch may be affected by nmoff. 3. FINANCE a. The financial book containing Income Statements and Balance Sheets for the year 2003 was passed around the room for the homeowners to view. 4. WATER&ROADSREPORT-FCDobbs a. FC sununarized the HOA's dilemma in getting the roads adequately worked on by Frontier Paving. In general, the work performed was sub- standard and we have insisted they come back to redo some sections of the roads. A few homeowners complained about the lack of compaction on Apache resulting in soft dirt b. We currently have one bid for snowplowing this winter and another bid is in the works. c. Some homeowners expressed their concern about the money spent on maintaining the "fire road" or the extension of Apache down to the Elk Run road. The recent work done there required a fair amount of extra dirt, thus there was the added cost of time and labor. A vote was taken to continue blading the extension. d. Instead of cinders or sand to be placed in oilr road barrels, we are looking into a natural substance called Ice Slicer. It costs $8.50 for 50 pounds and it doesn't take much to have an effect on icy surfaces. · 5. NEW BUSINESS a. Eileen Koch wished to revisit the subject of Board member compensation. According to her calculations it is costs the subdivision $13,000 annually for administration. This cost includes monetary payment to the directors as well. as the waiving of the monthly billings. Some homeowners feel the billings should not be waived. After a lengthy deliberation involving job descriptions and time involved, as well as the issue of how compensation packages have increased homeowner involvement in the Association, it was agreed that the newly elected Board of Directors would carefully create a compensation schedule that reflected all the present homeowners best interests. · b. By vote, the Board was granted permission to purchase a laptop 90mputer for the purpose of conducting HOA business. 6. VOTING a. A vote was taken to elect seven people to serve as the Board of Directors to the Elk Creek Romeowners Association. The seven elected homeowners were : Linda Carson, FC Dobbs, Sarah Pagni, Joyce Gaston, Eileen Koch, Laurie O'Connor, and Sheryl Klima. *Meeting was adjourned at 9:45p.m. *The next Board of Directors meeting was scheduled for Monday November 24, 2003 at 7:00p.m. Respectfully submitted, Sarah Pagni, Secretary MEYER s:u ~ \.. E Yo ~:s GLENWOOD $PI~IN(3S I 18 W. 6TH, SUITE 2:00 ASPEN CRESTED BUTrE P.O. BOX 21 55 P.O. eox 3088 GLENWOOD SPI'l!NGS, CO 8160 I ASPE:':N, CO 8 16 I 2 CRESTED BUTIE:, CO 8 I 224 970·945-1 004 970-925-6727 970-349-5355 FX: 970-945·5948 FX: 970-925-41 57 FX: 970-349-5358 [Vlr. .John and Mrs. Eliz.abeth Douglas 0149 Apache Drive New Castle, Colorado 81647 RE: Foundation Design for Residence Addition at 0149 Apache Drive, New Castle, CO Lot 9, Block 6, Unit 1 of Elk Creek Development Dear John and Elizabeth, Please find attached hand drawn sketches of details for construction of the proposed addition to your home at the above referenced address. We have prepared these sketches based upon information supplied to us from yourself including the ILC prepared by High Country Engineering and the hand drawn foundation plan, elevation and floor plan prepared by yourself. Based upon this information as well as your description of the construction of the existing home, please note that we have prepared these sketches to aid in accomplishing the proposed construction. Please note the following: 1. The minimum joist necessary to carry the 15' span indicated is a 9 %" T Jl 210 spaced at 16" o.c. This joists can carry a 15'-9" clear span under a 40 psf live load combined with a 20 psf dead load. 2. For the porch framing, given the proposal to install 3 porch posts, we would recommend that each post support be provided by installing an isolated pier/footing foundation to a depth of 36" below finish grade to bottom of footing. The concrete pier will need to have a standard Simpson post base installed to match your intended post size. We would recommend a minimum post size of 4x4. There will need to be a minimum of 6" from the top of concrete pier to finish grade. The footing would be recommended to be 24" square X 10" deep with 2#5 bars each way located a minimum of 3" from the bottom of the footing. We would recommend that the pier be a 1 0" diameter pier with 2#5 bars placed vertically out of the footing into the pier. The height of the 2#5 bars would be equal to the height of the pier. 3. This design has been prepared without the benefit of a soils report. However, the design has been prepared to maintain consistency with adjacent observed construction and minimum on site soil strength assumptions of 2,000 psf for allowable bearing, 50 pcf for equivalent fluid weight of soil, 120 pcf for density of compacted on site soils, footings to be placed on native undisturbed soil, footings to not be placed on fill, all adjacent construction is that of stem wall/footing construction and no ground water nor leach field influence is to be expected. If, during excavation, it appears that any of the assumptions are awry, we will need ~~----::::? --~ ~Fflw COr( ci. 00 J ~1 .. 11 i SCHMUESER ···i·-········---\·-··----·--·-!·-----·--·---·: I! c;dF<~bN I MEYER I. J ' l"~INEERS i I I to be contacted to modify our recommendations. We do recommend that a geotechnical engineer be contacted to observe the onsite bearing soils to confirm the soil ,strength assumptions made. 4. The design has considered a 40 psf live load for the roof as well as the 40 psf live load for the floor. 5. As this is an addition, it is critical to note that there WILL be differential movement between the existing building and the proposed construction. We have tried, however, to minimize the effects of this movement by providing solid ties of reinforcement between the existing and proposed foundations. Drywall cracking at the common walls can be expected and will possibly require future repair through possible re-taping, patching, caulking and/or painting. Upon your receipt and review of this letter and the information attached, please don't hesitate to call if you have any questions or concerned with the information. Respectfully submitted: IMPROVEMENT L.OCATION NOTC: PNIClfL DOE!S NOT MATfll!MAnCALLY CLOSE!. PROPERTY DESCRIPTION CERTIFICATE I 0/49 APACHE DRIVE LOT9 8LOCK6 COUNTY OF GAf/Fil!LD S7:4T£' OF COLORADO //NIT I OF E:LK CRE:l!K Dl!VE'LOPME:NT IMPROVEMENT LOCATION CERTIFICATE I HEREBY CERTIFY THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PRE- PARED FOR JOHN F. AND £'L!ZA8£'TH M. DOUGLAS , THAT IT IS NOT A LAND SURVEY PLAT OR IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. IT IS HEREBY STATED THAT THE STRUC- TURES LOCATED ON THE ABOVE DESCRffiED PROPERTY ARE NOT LOCATED WITHIN THE 100 YEAR FLOOD BOUNDARY. ]OBNO.-----------------------= ~ COUNTRY ENGINEERING, INC. SUITE 2Q5, 118 W. 61h. STREET GLENWOOD SPAJNOS, CO 81601 (303) 945-8676 6' SCHMUESER I GORDON I MEYER ENGINEERSISURVEYORS ··~~----------------------------- ., ,, ~ GLENWOOD SPRINGS ASPEN CRESTED BUTTE MEEKER I I 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, CO 81601 970~945~ 1004 FX: 970~945~5948 P.O. BOX 2155 ASPEN, CO 81612 970-925-6727 FX: 970-925-4157 P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349-5355 FX: 970-349-5358 320 3AD ST. MEEKER, CO 81641 970-878-5180 FX: 970-878-4181 a SCHMUESER 1 GORDON 1 MEYER ~ENGINEERS!SURVEYORS ~~------------------~~. SCA'-"'----------------------------------· -·-- -~·-· ~:~.~! 'i -~ ~~-· ' ::it. ~ .;' ~· •. ~ ·--~)! ... ·!!'-" -~--~·-· . --r· ~ (S ~-· "'--.} ~-J ~ •lV Q, jl tt ~i '~-::! -· J~-' ... ~-;:: ~} "-C\ '2 ~ ;;( ,j .~ i~ ! ,fl . C) ,. -·~~~ ' l-it 1\ I i.-.. \:f J ' ' ~: . ~rD~ ]~Ji ' _JJ' .. "Y' ~~ ' " ~~ '----'. . )< ~ {\~ " 1\1' :> ~ C?S:·· GLENWOOD SPRINGS 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, GO 81601 970-945~1 004 FX: 970-945¥5948 ASPEN P.O. BOX 2155 ASPEN, CO 81612 970-925-6727 FX: 970-925-4157 CRESTED BUTTE P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349-5355 FX; 970-349-5358 MEEKER 320 3RD ST. MEEKER, CO 81641 970-878-5180 FX: 970-878-4181 6 SCHMUESER I GORDON I MEYER ENG!NEERSISURVEYORS GLENWOOD SPRINGS 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, CO 81601 970-945v1 004 FX: 970-945-5948 ASPEN P.O. BOX 2155 ASPEN, CO 81612 970-925-6727 FX: 970-925-4157 CRESTED BUTTE P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349-5355 FX: 970·349-5358 MEEKER 320 3RD ST. MEEKER, CO 81641 970-878-5180 FX: 970-878-4181 6 SCHMUESER I GORDON I MEYER ENGINEERS]SURVEYORS l/z:.'1 o, :5'.0. · oJZ, ·· : . · PL-'1 ~CO.~ :?li£Ejn:bN~ lMJOek .BLOb \Jf/?AP 'i:. sYD\rN l.,. . - i Jf(o'l'' r .. L -:t· 1a.. ::: 3QL)Of':%t i~. ::o .4n ~i- ! 3/#'' .. ~ .. ;tf/1.:? Y, .·~ ··-\~ ' ' pRQ.,L~.C.· --·----- SHEET NO .c.8l...CUI ATED ey • CHECKED S:lO.·---------""""'"---·------ IL. ··~· ~~~ Tt /.:::, fL~.,,LD c:f\2-.. 0$8, ftCD.if.:'rti-Lb {..;C::oLi.4'. '1>~. Ntri l. . ~it) . 0&.;;.\:;j; J ,Jo\:S>o (it \ 0l1llC' ~&> .wow .. ft A-Nllt-Qt![:;?[) TD -:7\-rFl:J.J.. l~t-< "vI Vi.'' 6l /bJUbr<: . .. t:Qll-'? Q_4eJa- GLENWOOD SPRINGS 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, CO 81601 970-945-1004 FX: 970-945-5948 ASPEN P.O. BOX 2155 ASPEN, CO 81612 970-925-6727 FX; 970-925-4157 CRESTED BUTTE P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349-5355 FX; 970-349-5358 MEEKER 320 3AO ST. MEEKER, CO 81641 970-878-5180 FX: 970-878-4181 6 SCHMUESER I GORDON I MEYER ENG!NEERS!SURVEYORS eao <ECT· f0w6kt'7 tf~)/),~>..1 =DSY J'i> FRO'~~----------------- I ___ , __ ····t····· -~ "" ---j-...... ~ •..••.. ; .... I .... ;. -----~-....... :·· . :... ......... L ............. . i ...... , ... ······i·· ..... , ........ , ........... .. i : 1 •••••• ; •••••• 1 .. -.... ,, __ . ··i····· "i•'• ···+--····t· --.-+ .. ·· --~---... ;.. -----j----.--+ ---···;··· i GLENWOOD SPRINGS 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, CO 81601 970~945~1004-FX: 970-945~5948 ASPEN P.O. BOX 2155 ASPEN, CO 81612 970~925-6727 FX: 970-925-4157 CRESTED BUTTE P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349-5355 FX: 970-349-5358 MEEKER 320 3RD ST. MEEKER, CO 81641 970-878-5180 FX: 970-878-4181 6 pRQ!ECT• ()~-\t;~------·~RRQ~!-0#~--------------------- SCHMUESERIGORDONIMEYER ENGINEERS\SURVEYORS SCALE;_ ________________________ _ i .. '" . •.. . . ·--~" . ···l·. ... ···i· ------~ .. ····'" ; ...... _; __ .... · .J . . ... ! ------~- ' . . . .. . .... -r---... ~--... ---~ ( ....... · .... ---:-...... , .• ····l'----~ ------~--.. .; .... ···f·· -· i r:::~t$nAn;;' · · ·· ··· ~ f'~~o~· ____ , ____ ·;t .... , . ._ ---:· -----L_::··· . . " -" . ~--· . ". ~ ... !. ___ ,_ "(" ----~---"··i· -----~-...... , ······;·· ----~-------~-- __ ..t "''""••j _____ J ---~ .. --. ---.. )-····••!"" . ·--------!-----.~---···) ------:···· "'i""" ... ,l ...... J., ... ... ~-..... -:--------~-""' .. :··-.. -~-----... , .. '""\"" .; .... ' 'T"' ---~-·---------.. .L .... __ , __ ... ;-------;-\ ·r··· --1------f--------1 .. ; ..... . i . -----~------:--" " ·----. --~ . "--·: .. " .. "'~-- _j_ .L i ·:··'"'" ... ·.!·· ' ti/Ph0 Powe_JL>: : . Z¥4 bii[iif;j;-.:;tze:;;fy ········ ' ' . + ' ' ~----.,....-. ~--: ...,~..,........., ··'"····--r--+-,_..,..._._..__.__;--_,_____,_-t c r4'5"' · , t ~:::r=~c:-~~-.':5' ..... :cc= ...... F .... -~-..... ± ..... cc::+ ..... ;:.-.c.~::L ..... ;........ . . . . ·+· .... ; .... :·· ··; . , .. : ...... ~~-+ , ..... +::;~L .. ::::; ·,::L , ::L:ht~:-··· ~I~~~-L ! \···· i i . : ...... ········•·· ·,m~±J~;h~_ .. , ~l~~t:rr .. ::,:~~[) .• i···;i;. :~t:~~j:: : ... : .. --+ , , ....... ~~n!N\L. f.... ;Pbli:Vt,;:~ .... \ ... i .. ,_ I?::G1Jel ~ totf.~'-4: ze.::/r) : : , i I fp~~~~LiL~J.Y![·: i : : ..... ; ....... · ... ····'· T . . ~~ Lt~ArP ~(.::;;rJf.'tL., . !. 1 ... --:"· ...... ~----.... · -· .1 ....... : ··---i--. ......... ; .. -----~----T:::_·:_r--- .. \ . . .... ;. .. --]·------:·--......... ~ .. : ....... .;-.... .) ... L ' · • ' 4o7~ : ~ I · +t · 1 , :~.····· , JuUit0r\t '~;.;.t;;;;;;' , .. , ..__,_...,.~--,~~~~~ .. --~-......•....•..•.. ""1" ...... """f"' --·(----""i"' ·.·.·_·i.'.·_··. l. .... ; -------:--··----~---... ( . .- . . . .... ,.. .. -~---.... 'f. .. ---~-. ... .. . .. .. !. . ---~-.. ---~------~----· --i--... , .. ! . ----~-----:-· .). -~-----+--· j " .... -~--··--·:·· . .. ... ~--... ~--.... -:-··· .. • ....... ; ... --: .; . " -.. j ..... --:· . -----~ ...... :-- : : ..... ----:---. ""1"" ... ~------~---... j .... ; .. -1--... : ........ _\ • ........ ----i---"""'1""'" ... ·. ---:--· ....... ··i--·--·'" . ............ : ...... L ... , .. . -~-------:-- ----:------·--------:· I ' ........... ... j .... ----~--·+· ···:··. ··"·'"" """"]""""" .! .. i .. -----~-........... ,,. ---··r--···! ....... --f--··· I ""'-\--... -;-. -----:----... ;. ----+ """""")"'"" +-----; .. ----~-------~----.j -)·-----1-------;--· ... f .... GLENWOOD SPRINGS ASPEN CRESTED BUTTE MEEKER 118 W. 6TH, SUITE 200 GLENWOOD SPRINGS, CO 81601 970·945-1 004 FX: 970·945-5948 P.O. BOX 2155 ASPEN, CO 81612 970-925·6727 FX: 970-925-4157 P.O. BOX 3088 CRESTED BUTTE, CO 81224 970-349·5355 FX: 970-349-5358 320 3RO ST. MEEKER, CO 81641 970-878-5180 FX: 970·878-4181 i) d'-. ~' v .. 24 2• "3 '-../ 22 21 ' 2( c :Tf! I I T"i ' -;;r. 18 ' l ;-· 15 14 ~ : 13 '2 ~ 11 ''-· -l,: 'J 10 I I 9 j .l l 8 I 8 ~:+ c-J; "1 7 -~! I! < ... 6 < i 5 t-li I' 4 li ,, 4 t 3 r- i~ 2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 r·, .. 0 ;. Lc"'.¥' =r[JL.Lil\ Ct;ti 0Vt !.' 24 2' "' ''-._./ 22 ' ' f"'~l 21 r;· 41 :··. 2( i '1 . } r 1t\ j_ I .i ' I i I 18 1.7 , ,I - 1b t;:i '· i ' I' 1E I 1s 14 13 "Q 12 '-._____/ 11 10 9 8 8 L 7 6 5 4 4 3 2 ;;:~;- '- -._____/ tj·; oi + dhi-~ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Dc:oV'? ~ liD!n.dt.>(J..)':> F l(o(\t door--(z_y~' '~--I') fotcltn.S c,Los.L-1-da.w----(S'"il) UVIv>ciO\b -(5' 'X s I) ~ \JDIV'-cLtLD c_t.i'xs') 11228 No. --------------------A • p I N 2125-21-06-009 ssessor s arce o. -------- Date ___ 2_11_3_12_0_09 __ BUILDING PERMIT CARD JobAddress __ ~0~14~9~A~p~ac~h~e~D~r~·~N~e~w~C~a~st~le~------------------------------------ Owner __________ o_o_u-=-g-la_s_, J_o_h_n ______ Address __ s_a_m_e _______ Phone # 970-984-3378 Contractor Owner Address same Phone# 970 -989 •0139 Setbacks: Front _______ Rear _____ RH _____ LH _____ Zoning -------- add to living rm on crwsp & cov patio Soils Test -:;;o----r.:~,........,,....,..:---:.,....,..--------- Footing 3~f2"Pif ~ Foundation S "IS-ir(.l.4nA Grout ____________ ___ Underground Plumbing ---.-.r-:----- Rough Plumbing '""htt- Framing & -II~ oq Ji3w1 Insulation ? -15-fJ '1~ Roofing------------- Drywall ------------ Gas Piping __ c..,;!'=-------- INSPECTIONS NOTES Weatherproofing ________________ _ Meehan ical_"'?-vt-..::...::=.=.. __ --.,-----.r::---:-.,.--.,-r------ Eiectrical Rough (State) -/{)-t> q I. Electrical ..F. i n~J (State ) _ _,.{,"--p .tl:!!...l---_,.t)'--'-~--'""'-'--;;>""t:;;.,..­ Final/6 -0-12':{ /Checklist Completed?-~""'"""­ Certificate Occupancy # -----------Dme _____________ ___ Septic System # ------------ Date ---------------Final ____________ _ Other _______________ __ (continue on back) BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued 2 • l 3• O'J INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB Permit No._-l/u/_.l2fl ______ _ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. if\ (\ This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection INSPECTION RECORD Footing Driveway 3~)1-D9 ~ Foundation I Grouting Insulation ._.. ?} ~ 5-/5-01 ;9v1\ fc-/S -o Underground Plumbing Drywall ~ ~ f:,-)--3-U/ Rough Plumbing Electric Fi~~tat~ecto6f /tJ j -y'LbV (Prior to Final) zf; Rough Mechanical Septic Final -yv._, ~ Gas Piping ~ fiNAL fJrlv /l-3 -tJ1 Electric Rough (by Stale ln~j~:J (You Must Call For Final inspection) tp,;ono ,,f:,f.: ,jy {? (O Df / Notes Framing b _ 1/-oq ~ ()~ (to include Roof in place & Windows & Doors installed & Firestopplng in place) THIS PERMIT IS NOT TRANSFERABLE For Inspection Call970-384-5003 OIIice 970-945-8212 108 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD ~::eROVED 2 •13• D~ 'F" h.rii'V\fl~A J. ~ PROTECTP:~MlT~MW~...,...,.....-~ (DO NOT LAMINATE) .• v I I I I I I Parcel Detail Page 1 of4 Garfield County Assessor/Treasurer Parcel Detail Information AssessoriTieasurerYrop_ert)T Sem:ch I A_ssessor Subset Qu~ I AssessQTJ;ales s~rch Clerk &_Recorder Rec~p!ion Se<rrch !"_.<rrcel D5'tail I V alu~ Detail I Sale_s_Detail I Resid\JntiaJ/C_ill!lillercial Improvemen1J2etail .l&n~ Detail I ~'holographs I Mill Lerr1\evenues_Detail I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 013 II R013132 II 212525106009 II 39.877 I Owner Name and Mailing Address !DOUGLAS, JOHN F. & ELIZABETH M. 1149 APACHE DR !NEW CASTLE, CO 81647-9707 Assessor's Parcel Description (Not to be used as a legal description) ISECT,TWN,RNG:25-5-91 SUB:ELK CREEK IDEV. BLK:6 LOT:9 DESC: UNIT 1 IBK:0505 PG:0303 BK:0463 PG:0264 IBK:0768 PG:0008 Location I I I I I I I I Physical Address: 11149 APACHE DR NEW CASTLE I I Subdivision: IIELK CREEK DEV. I I Land Acres: lio I Land Sq Ft: 1110,525 I I Section II Township II Range I I 25 II 5 II 91 I 2008 Property Tax Valuation Information http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=2125251 06009 12/2/2008 Parcel Detail Page 2 of4 II Actual Value II Assessed Value I I Land: II 76,oooll 6,o5oj I Iml!rovements: II tt4,530II 9,1201 I Total: II 190,53oll t5,170I Most Recent Sale Sale Date: llll/30/t989 Sale Price: \l6t,OOO Basic Building Characteristics Number of Residential t Buildings: Number ofComm!lnd 0 Buildings: I Residential Building Occurrence 1 Characteristics I I 1 STORY: 1!972 I I TOTAL HEATED AREA: 11972 I I ABSTRACT CODE·IISINGLE FAM.RES- . IMPROVEMTS I I ARCHITECTURAL STYLE: Ill-STORY I I EXTERIOR wALL: IIALM SIDING I I ROOF COVER: IICOMP SHNGL I I ROOF STRUCTURE: i!GABLE I I INTERIOR WALL: IIDRYWALL I I FLOOR: llcARPET I I FLOOR: JlsHT VINYL I I HEATING FUEL: IlGAS I I HEATING TYPE: i!HOT WATER I I STORIES: llsTORIES 1.0 I I BATHS: It I ROOMS: 15 I UNITS: It http:/ /www.garcoact.com/assessor/parcel.asp?ParcelNumber=2t25251 06009 t2/2/2008 Parcel Detail I' Tax Information I Tax Year II Transaction Type II Amount I I 2007 II Tax Payment: Whole II ($604.92)1 I 2007 II Tax Amount II $604.921 2006 II Tax Payment: Whole II ($473.48)1 2006 II Tax Amount II $473.481 2005 II Tax Payment: Whole II ($473.60)j 2005 II Tax Amount II $473.601 2004 II Tax Payment: Whole II ($523.94)1 2004 II Tax Amount II $523.941 I 2003 II Tax Payment: Whole II ($588.54)1 I 2003 II Tax Amount II $588.541 I 2002 II Tax Payment: Second Half II ($266.68)1 I 2002 II Tax Payment: First Half II ($266.68)1 I 2002 II Tax Amount II $533.361 I 2001 II Tax Payment: Whole II ($530.18)1 I 2001 II Tax Amount II $530.181 I 2000 II Interest Payment II ($2.52)j I 2000 II Interest Charge II $2.521 I 2000 II Tax Payment: Second Half II ($252.48)1 I 2000 II Tax Payment: First Half II ($252.48)1 I 2000 II Tax Amount II $504.961 I 1999 II Tax Payment: Second Half II ($251.14)j I 1999 II Tax Payment: First Half II ($251.14)1 I 1999 II Tax Amount II $502.281 T.9.12ofYage Asses.sor :Qatab~e S~_arch()_pJiQ_ns I Ir.easJJ.rer Da!abase Sean:h Options Clerk_ & ReNrder l2ataba~e Se.an:h OptioJls http:/ /www.garcoact.com/assessor/parcel.asp?Parce1Number=2125251 06009 Page 3 of4 12/2/2008