Loading...
HomeMy WebLinkAboutApplication-PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Offlce:970·945-8212 Fax: 970-384·3470 Inspection Line: 970·384·5003 Building Permit No. /122CJ Parcel No: 2393-321-00-378 Locality: Job Address: 1447 CR 108 Carbondale Contractor: Structural Associates Fees: Plan Check: 704.18 Septic: Bldg Permit: $ 1,083.35 Other Fees: _N ___ ''"-·-~•"•'- Total Fees: $ 1,860.53 Clerk: Q;thQ.4Jj2 SQ'l._ __ Date: $ 73.00 -----"---"··~---~ . ·-·~·------"···--·~--··· 2_13. DC?f_ ... _ I ··~ l 2 3 4 5 6 GARFIELD COUNTY BUILDING PERMIT APPLICATION 108 gth Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-82!2/ Fax: 970-384-3470 I Inspection Line: 970-384-5003 www .garfield-countv .com Parcel No: (this infonnation is available at the assessors office 970-945-9134) Z3"\-s"Sz. 1oo ~·s Job Address: (if an address has not been assigned, please provide Cr, Hwy or Street Name & City) or and legal description \441 Cov~ IL.\) \D'il" C..J'\12--TSoiV"\;>P\1..-G co Bt<..."L <; Lot No: Block No: Subd./ Exemption: It" ~wner: (proper~ owner) Y£.:t1 Mailing Address: Ph: '-JZ>iSm-L 12t w--(l.. I?A;.Vi e..o \410 GQ.lO'il' Cf\-e.-l~n"iJiA:LG "'t(,;~ -"2-244 ~ontractor: Mailing Address: Ph: :nz,Jt;\Vll-V(t._ 1\Ssoct~res 4t'i;::;:, GIL I 9f GvvS "!4S-Ol41 Ph: ~A~~; 'V'II~ --1' ~ltPh: .' '3.1"'\-s <;~ Alt Ph: Architect 1 Enr~er: 1011\J\W\..E iDtt-J\S VJ\....=z;, T p~ailing Address: 0 130'!C l?-t\1-lf A-lL co CJ4'1-c.. G, "?;"\ 7 Sq. Ft. of Building: Sqi£k Ae~ c::J:J.g T Hri~\: ,1 No. of Floors: t oe-z.. ~ I -0 ?.. 8 u~~~e-, LE:; 0-t.tA ·.; .. Dk. Ao r.. ...P:ru •• ~ . !'{'\ ~ ~ /}, tJJ( cw .. ..0" .IL 9 Describe Work: u I " (J Nl::;.-w C.MJ'7 "0/W'c.no i--> 10 Class of Work: rk!cw o Alteration o Addition 11 Gara/5/A Septic: l)!:;(SDS o Attached 0 Detached o Community 12 Driveway Permit; 1'-J/A Owners valuation of Work: $ I 1'?, I "'iS NOTICE Authority. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. lfthc signature bdow is not that of the Owner, a separate Jetter of authority, signed by the Owner, must be provided with this Application. Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Department. Other Permits. Multiple separate permits may be required; (I) State Electrical Permit, (2) County ISDS Pcnnit, (3) another permit required for usc on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Pllrllli! A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. CERTIFICATION I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Department accepts the Application, along with the plans and specifications and other data submitted by me or on my bchalf(submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structurc(s) and facilities detailed on the submittals reviewed by the Building Department. In consideration of the issuance of the Building Permit, J agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, ISDS regulations and applicable land usc regulations (County Rcgulation(s)). I acknowledge that the Building Pennit may be suspended or revoked, upon notice from the County, if the location, construction or usc of the structure(s) and faci!ity(ics), described above, are not in compliance with County Rcgulation(s) or any other applicable law. I hereby grant permission to the Building Department to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Pcnnit does not prevent the Building Official from; (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or usc of the structurc(s) or facility(ics) if such is in violation of County Rcgulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the B11ilding Department do not constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without iim;<ot;,, my '"";tocl d";goe<, oog;"'" '"mr ~~ '·· DUNDERSTANDTHENOTICE&;;;;T;ABOVE OWNERS SI~ATURE 'V--' -D.£-I f . f STAFF USE ONLY Special Conditions: Adjusted Valuation: Plan Check Fee: Permit Fcc: Manu home Fee: Mise Fees: t~S;n5. '1f4 7tJI.f. :;8 102$.3,5 tJlf/!t --ISDS Fee: Total Fees: Fees Paid: Balance Due: BP No & Issue Date: ~~[;; /4{;;azc, 7'7!!1. ff{'foo .53 lo'f.l<g J(S'(,. 3~ 11229 2.! Setbacks: OCC Group: ConstType: Zoning: I R.. B~DEPT: ~ v ~/tt>/o<j P~GDEPT: tl&ld'f L~\ ~}\\~\ ~~\\~,~~ APP AL DATE APP OV DATE " The following items are required by Garfield County for a final Inspection: I) A final Electrical Inspection from the Colorado State Electrical Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road . . 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, sink with hot & cold running water, non-absorbent kitchen floor covering, counter tops and finished walls, ready for stove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold running water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers, outside or inside must be must have handrails. Balconies and decks over 30" high must be constructed to all IBC and IRC requirements including guardrails. 6) Outside grading .completed so that water slopes away from the building; 7) Exceptions to. the outside steps, decks, grading may be made upon the demonstration of extenuating circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be issued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAl, OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, nse and the issuance of a C.O. for the building identified in the Building Pennit. I DATE Bapplicationdecember2007 VALUATION FEE DETERMINATION Applicant Address Date -:=C:;.ry~s:,'!ta;l ~R~iv,:::er:-'R~an~ch~,.::c~ar~etak::::;e;r_,un!!;i:.:..t __ Subdivision -;;1..;,44,:,;7:,:C:;;R:,:.;:.l 0;:;.;8;.,.,.;:C:::ar:.;:b..:;on;:;d:;:;a::.:le._, C..:;O.:;_ ___ Lot!Biock .=2:..::16;:;.;12::.:0:.;:0::.8 __________ Coutractor Finished (Livable Area): Main Upper Lower Other Total Basement: Unfinished Square Feet Valuation Conversion of Unfinished to Finished Total Valuation Garage: Carport: Total Valuation Crawl Space Total Valuation Decks/ Patios Covered Open Total Valuation Type of Construction: Occupancy: · Moda!ilf'llet foe Valuation Total Valuation 760 sq.ft 322 sq.ft sq.ft sq.ft X $74.68 1082 sq.ft sq.ft X $41.00 sq.ft X $33.68 sq.ftX $18.00 sq.ft X $12.00 760 sq.ft X $9.00 1148 sq.ft X $24.00 sq.ft X $12.00 Commercial 126 sf sf sf sf sf sf ffZ.;;~D~. f~ tt; r c 1D1:J .3£) ('l8'l. '53 X $9.99 X X X X X 80,803.76 0.00 0.00 6,840.00 27,552.00 NOV-20-2007 08:56 OHM DESIGN &. PLANNING DEPARTMENT AGRICULTTJ.RAT.. EMPLO'nE AFFIDA 'Vlt . FOR :EMPLOYEE HOUSING I, Sue Rodgers , state ~t the residential strUcture described below will be occupied solely as an agricultural employee dwelling unit provided to im individual and related family member who is/are employed in an agiicul tural use, including farms, garden, greenhouse, nutS cry,. orchard, ranch, small animal farm for ptoducti.on of poulti:y, fish, tbrbearlr~g or other Sl't\all animals, as . prescribed in Garfield County Zoning Resolution Section 3.02.01 and in Section 2.02.02 Agrioulhl.ral Land, Ol'l the property at which the dwelling is located and :further, pays no rent. · · · It is agreed that proof of employment, in the form ofintema!·R~venue Service Forms W:-2 or 1099foaach person, employed. as i:lescri"bed above will be submitted to the Oar.5eld County B11ilding an~ Planning Depamnen.t upon request by the county. It i$ agreed that this property will not be sold to another party without repre$enting that the agricultural employee dwelling structure is for agricultUral employees· only and may . not be used fora.ny other purpose. · · Property and Building .Description; Addre~s 1447 County·Road 108, Carbopdale, CO 1!1623., .Assess9r Parcel Number...;''~· '""' . ..r,.2x.;39t;~3~32&..1!.!10:~~.03i!.<7uz8 _________ __.;. __ _ ·Building D&:.\lcrlption Agric;yltural emplo)!~>e dwelllng(sl :Buildmg Square l'e~ Habitable Varies · · Building Permit Number...,..,..._~--------------- lSDS (Septic:)Pennit Num~~-~;.;........_:..._.. _ _.... _ __,. ______ _ Own,~~::;L..::::.a:;z._y.:~..t:L..~-:-:-~~~-:-::-"'"'::'-:--:-7'"--:(Signat\:lre) Owner . Box 68 Carbondale CO 61623 Date (f/j_~ :]_· ·· ...j-'-h Witn)1&;6~ 4w . Agbsg9/2004 ' · 108 8th Street,S!J.ile1!.01,. Gle'I!Wood Springs, Colora~o 81601 (910) 945-821~ . . (970} 285-7972 · r(JX: (970J 384-3470 TOTAL P.00\3 Plans must include a floor plan, a concrete footing and foundation plan, elevations all sides with decks, balcony, steps, hand rails and guard rails, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom of the footing to the top of the roof, including re-bar, anchor bolts, pressure treated plates, floor joists, wall studs and spacing, insulation, sheeting, house-rap, (which is required), siding or any approved building material. Engineered foundations may be required. A window schedule. A door schedule. A floor framing plan, a roof framing plan, roof must be designed to withstand a 40 pound per square foot up to 7,000 feet in elevation, a 90 M.P.H. wind speed, wind exposure B or C, and a 36 inch frost depth. All sheets to be identified by number and indexed. All of the above requirements must be met or your plans will be returned. All plans submitted must be incompliance with the 2003 IRC. I. Is a site plan included that identifies the location of the proposed structure or addition and distances to the property lines from each comer of the proposed structure( s) prepared by a licensed surveyor and has the surveyors signature and professional stamp on the drawing? Properties with slopes of 30% or greater must be shown on the site plan. (NOTE Section: 106.2) Any site plan for the placement of any portion of a structure within 50 ft. of a property line and not within a previously surveyed building envelope on a subdivision final plat shall be prepared by a licensed surveyor and have the surveyor's signature and professional stamp on the drawing. Any structure to be built within a building envelope of a lot shown on a recorded subdivision plat shall include a copy of the building envelope as it is shown on the final plat with the proposed structure located within the envelope. Yes X: 2. Does the site plan also include any other buildings on the property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property you are applying for a building permit on is located on a comer lot. Special setbacks do apply. Yes >c 3. Does the site plan include when applicable the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to the property lines, wells (on subject property and adjacent properties), streams or water courses? Yes K 4. Does the site plan indicate the location and direction of the County or private road accessing the property? v Yes __ /\_,_ __ 2 5. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-8601. See phone book for other agencies Yes X 6. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordapce with the IRC or per stamped engineered design? Yes _ __,_)\_,_ __ 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearance<:'quired between wood and earth? Yes :;><_ No ____ _ 8. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes )( No ___ _ 9. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? Yes. __ ?(_,__ __ I 0. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes X 11. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes >( 12. Does the building section drawing or other detail include the method of positive connection of all columns af!d Jleams? Yes __ _:.~-'----- 13. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes )(' 14. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No ____ >( ________ _ 3 15. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes .)(' No ______ _ 16. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the IRC? Yes ..)(" 17. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes ><: 18. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes )( No ______ _ 19. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes )\ 20. Do you understand that if you are building on a parcel ofland created by the exemption process or the subdivision process, are building plans in compliance with all plat notes and/or covenants? Yes X 21. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the risk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not refundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocation or substantial modification of the plans. Yes tJ/A 22. Will this be the only residential structure on the parcel? Yes No Ifno-Explain: L-~e: IZAN4-t 23. Have two (2) complete sets of construction drawings been submitted with the application? Yes X' 24. Do you understand that the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes K 4 25. Have you designed or had this plan designed while considering building and other construction code requirements? Yes )\ 26. Do your plans comply with all zoning rules and regulations in the County related to your properties zonedis~t? Yes _______ _ 27. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes ?( 28. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes :X: 29. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road IJVpftct" or "Septic System" fees required, at the time you pick up your building permit? Yes. __ X:.:._ __ 30. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30 a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in ~e!84-5~ No . ____ _ 31. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-in§Pection fee? Yes __ .X._::_ __ _ 32. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes K 33. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes X: 5 34. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspection. Yes·------~----------- 35. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are applying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes. ____ ~~--------- 36. Do you know that the local fire district may require you to submit plans for their review of fire safety issues? Yes K (please check with the building department about this requirement) 37. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of a building permit that you will be required to obtain a grading permit? Yes >( 38. Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of Occupancy? Yes )( 39. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes I hereby acknowledge that I have read, understand and answered these questions to the best of "'"--"a~ility. Project Name: A l0€W Project Address: \ 44 L (days); 6 _>~7-''1,_---'S"-S~S:.c::D ___ ( evenings) C f:-'(' S TI\-L \2-'-V\::::.12. LO 11229 Assessor's Parcel No. 2393-321-00-378 Date ___ 2_11_3_12_00_9 __ No. -----c-1/JfOtt ~"'3.-oq J Lj'-/'f ,.... BUILDING PERMIT CARD Job Address ____ ~4_4_r_c_R_1_08 __ C_a_r_b_on_d_a_le ____________________________________________ _ Owner _________ c_ry...:...._st_a_l_R_iv_e_r _R_an_c_h_C_o_. _____ Address 1470 CR 108, C'dale Phone # 970-963-2244 Contractor Structural Assoc Address 4185 CR 154 GWS Phone # 970-945-0147 Setbacks: Front Rear ______ RH ______ LH Zoning 970 ·379 -55 RO ag emp hsg on crwsp w/ covered decks INSPECTIONS Ur;::-:> 7'1-,:s--bo 3 "''"' Soi Is Test __ ......,...,--=:...:----;;;~""""--- Footing j, --u;-oO( .J 42 Foundation ~ -U -t:f!O( lfML--3-,>-o"?<?:W. Grout ______________________ _ Underground PI u m bing --:-----:=------,.-: Rough Plumbing . '"L?-G,-Q 2 . 7?'.?0,. Framing .:52-(S?-=ac ~ Insulation !L_L./ ... 0...!:[_ lt:b:1] Roofing ---,..,.,... .. ::;-:;----:::---:?.,--------- Drywall S"-;).. ?5-D q @YYi Gas Piping------------------ NOTES Weatherproofing ___________________ _ Mechanical _________ --:r-=--=-----=::-7"<:--- Eiectrical Rough (State) ?f.-Z g-0 9' Electri9al Final (State) ________ ___,-;-;,.,-- Finallf-&.01 /Checkliljt Cctmpleted? l),f;: Certificate g~~-fJ=a.,.nc,.Y.7".?!?'"""T'r,p.::=::-S-~if2_._),_~_c:::>0--Jz'-----­ Septic System # -~__._{,..'d2"'--'-l ""=---------- Date _ ·-=-=~------- Final_6. J6. Ef/1 £JN8J Other _________________ __ (continue on back) BUILDING PERMIT GARFIELD COUNTY, COLORADO INSPECTION WILL NOT BE MIIDE UNLESS THIS CARD IS POSTED ON TME JOB Date Issued __ 1.-~\w~=()"-'}_.__ ______ Permit No. ____J\LJ\'-'/..,_,2:.""&)-'---------- AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structured for whi.ch this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building department and IMMEDIATELY BECOME NULL AND VOID. ~::~~~~~\=;ti~ ~~-ckOO Owne~ (lj~~ CD. Contractor~ kAOC... Building Permit Type ~l derr\io.J This Card Must Be Posted So It Is Plainly Visible From The Street Until Final Inspection Je# 379-s-6o 5 INSPECTION RECORD Footing z_-zo-o'T ?'(A)-Driveway ' Foundation I Groutinb-,~ 9-,-}b-O'{ .s-.:s-oc; -r:w. Insulation ~c.J./ -d1 N11\ Underground Plumbing Drywall S-2'3-o~ ~ RoughPiu.mbing 5-/-C) ( <j?.o/ Electric Final (by State Inspector) IP<IoctoF;n,,~Y l}r b/7--f(o( Rough Mechanical~/~ O i Septic Final ;;tdiJ._. " ,q_ Gas Piping FINAL f?-v!;-v'/ ~JW~ Electric Rough (by State Inspector) (You Must Call For Final Inspection) (Pdo<~ £7mlng) vW-11 2-{3 /o l_ Notes Framing s;=::-/ _s:::: tJ '1 r-W (to include Roof in place & Windows & Doors Installed & Fires topping in place) THIS PERMIT IS NOT TRANSFERABLE APPROVED Date For Inspection Call 970-3&4-5003 Office 970-945-8212 1 OS 8th Street, Suite 401 Glenwood Springs, Colorado 81601 DO NOT DESTROY THIS CARD '1--·\'b.cfl By-r;; 'hntWin~~ PROTECTPE~~~ (DO NOT LAMINATE) COUNTY OF GARFIELD-BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone(970)945-8212 Job located at /~ ¢= 7 c,.(' ' /t7 :r Permit No. --rh'-~/'----G-_Z.----J'/''----------- I have this day inspected this structure and these premises and found the following corrections needed: 0'?a';l for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date .s:?· /3 . 20 0~ Building Inspector ~~ ~~ Phone (970) 945-82~2 ,/ _ COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at --"/'-~:?-'-"4-"--LZ __ ~C2-K~--L;J_,t"--7-'==8'-. ___ _ Permit No. --'-/,1 /-"'Z-::_-z..=--'-Z:_. _________ _ I have this day inspected this structure and these premises and found the following corrections needed: 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. COUNTY OF GARFIELD -BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 Glenwood Springs, Colorado Phone (970) 945-8212 Job located at ~/-+'f~-?--+7 __ --'C~/(--"-'-,~/_CJ_?~--­ Permit No. 1/ Z-Z 7 I have this day inspected this structure and these premises and found the following corrections needed: GA.5 LoG L/e.-l(fZIC /1/6/ Ai.L_oW/Ct7 I FI~;C CANe!.( A/&tCP5 t?o;.J/z: c;;t?ai;"for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 4-z "7 20 0 '7 Building lnspect:r: ez~ ~ Phone (970) 945-8212 Parcel Detail Page 1 of5 Garfield County Assessor/Treasurer Parcel Detail Information Assessorffreasurer l'ro_Jlerty_s_e;rrch I Assessor S_ubset Qy.e_rx I Assessor SruJJs Search Clerk._& Recorder Recention Sem:ch I'.<!Jcel Detml I Y.alue Detail I Sru.e_s Detail I Residential/Col])JllerciatLll1!2rov_ement Detail .Land Detail I PhoJQgmplls I Mill_Len: Rey§lues D.eJiiil I Tax Area II Account Number II Parcel Number II 2007 Mill Levy I I 010 II R100165 II 239332100378 II 60.865 I Owner Name and Mailing Address !cRYSTAL RlVERRANCH COMPANY 1555 17TH ST STE 2400 !DENVER, CO 80202-3941 Assessor's Parcel Description (Not to be used as a legal description) ISECT,TWN,RNG:32-7-88 DESC: SEC.19 !LOTS 2,13,14, & SW, SE. LOTS l8,9,11,12,15,16,17. SEC.20 ALL THAT !PART OF LOT 14 LYING ABOVE THE !SIEVERS DITCH. SEC.28 ALL THAT LOT lt4. SEC.28 & LOT 4. SEC.33 LYING ISWL Y TO THEN LINE OF LOT 14. lsEC.33 (39.42)AC. SEC.29 LOTS 16,14,15,16, 17,18,20,21,22,23, ALL !THAT PART OF LOTS 4,5,7. SEC.30 1&32 ALL. SEC.33 LOTS 5,13, W2SW. 18-88 SEC.4 LOTS 3,4,5 S2NW, SW, IW2SE. SEC.5 LOT 4, E2, NENW, S2NW, lsw. SEC.6 LOTS 4,5,6, S2NE SE. !EXCEPT A TR CONT. (128.99) AC AS http://www .garcoact.com/ assessor/parcel.asp?ParcelN umber=23 9 3 3 21 003 78 I I I I I I I I I I I I I I I I I I 11/17/2008 Parcel Detail Page 2 of5 jDESC IN BK 948 PG 650. EXCEPT A TR I jCONT. (.342) AC AS DESC BK 1190 PG I j91. ALSO A TR OF LAND ADDED CONT. I Jc.610) AC. AS DESC BK 1190 PG 91. I jEXCEPT A TR OF LAND CONT 27.223 AS I jDESC IN BK 1238 PG 400. ALSO, A I jTR OF LAND CONT 29.650 AC AS DESC I jiN BK 1238 PG 400. SEVERED I jMINERALS 8008-040-07-000, I j8008-050-07-000 PRE:R010097 BK:0976 I jPG:0976 BK:0948 PG:0650 BK:0713 I jPG:0480 BK:0713 PG:0470 BK:0702 I ~G:0169 BK:0411 PG:0193 BK:1613 I jPG:320 RECPT:657861 BK:1402 PG:384 I jRECPT:613836 BK:1402 PG:326 I jRECPT:613834 BK:1402 PG:302 I jRECPT:613831 BK:1402 PG:290 I jRECPT:613830 BK:1402 PG:275 I jRECPT:613829 BK:1402 PG:197 I jRECPT:613820 BK:1402 PG:195 I jRECPT:613819 BK:1402 PG:l92 I jRECPT:613818 BK:1238 PG:409 I jRECPT:577734 BK:1238 PG:400 I jRECPT:577733 BK:1238 PG:393 I jRECPT:577732 BK:1238 PG:390 I jRECPT:577731 BK:1238 PG:384 I jRECPT:577730 BK:l238 PG:367 I jRECPT:577792 BK:1190 PG:91 I jRECPT:564261 I Location I Physical Address: jj1443 108 COUNTY RD CARBONDALEj I Subdivision: J I Land Acres: JJ3228.345 I I Land Sq Ft: Jlo I Section II Towns hi~ II Range I I 32 II 7 II 88 I http:/ /www.garcoact.cornl assessor/parcel.asp ?ParcelN umber=23 93 3 21 003 78 11/17/2008 Parcel Detail Page 3 of5 2008 Property Tax Valuation Information II Actual Value II Assessed Value I I Land: II 370,noll 107,5001 I Improvements: II 1 ,251 ,noll 111,3801 I Total: II 1,622,64011 218,8801 Additional Value Detail Most Recent Sale Sale Date: 113113/2001 Sale Price: 11440,000 Basic Building Characteristics Number of Residential 7 Buildings: Number of Comm/lnd 0 Buildings: I Residential Building Occurrence 1 Characteristics I 2 STORY: 11873 I HALF STORY, FINISHED: I 775 UNFINISHED BSMT: I 775 1 STORY: 11835 I TOTAL HEATED AREA: 113,356 ABSTRACT CODE·IIFARM/RANCH RESIDENCE-. IMPS I ARCHITECTURAL STYLE: 112-STORY I EXTERIOR WALL: IIWOOD LAP ROOF COVER: IICOMP SHNGL ROOF STRUCTURE: IIGABLE INTERIOR WALL: llcUST PANEL I INTERIOR WALL: IIDRYWALL I I FLOOR: IIHARDWOOD I I HEATING FUEL: IlGAS I " http://www .garcoact.com/assessor/parcel.asp ?ParcelN umber=23 93 3 21 003 7 8 11/17/2008 Parcel Detail HEATING TYPE: IIFORCED AIR I STORIES: llsTORIES 2.0 I BATHS: I 6 ROOMS: I 13 I UNITS: II I BEDROOMS: Is I YEAR BUILT: 111937 I Additio.!l!!l Residential/Commercial ImproY~mentJ2§1ail Tax Information Tax Year II Transaction Type II Amount I 2007 II Tax Payment: Whole II ($13,322.12)1 2007 II Tax Amount II $13,322.121 2006 II Tax Payment: Whole II ($13,416.56)1 2006 II Tax Amount $13,416.561 2005 II Tax Payment: Whole ($14,181.20)1 2005 II Tax Amount $14,181.201 2004 II Tax Payment: Whole ($13,400.22)1 2004 II Tax Amount $13,400.221 2003 II Tax Payment: Whole I ($11,280.28)1 2003 II Tax Amount II $11,280.281 2002 Tax Payment: Whole II ($11,820.40)1 2002 Tax Amount II $11,820.401 2001 Tax Payment: Whole II ($11,887.22)1 2001 Tax Amount II $11,887.221 I 2000 Tax Payment: Whole II ($13,380.74)1 I 2000 II Tax Amount II $13,380.741 I 1999 II Tax Payment: Whole II ($13,199.38)1 I 1999 II Tax Amount II $13,199.381 MilL~n Revenues Detail TopofPa~ Assessor Databa~_SeJJI~lLO!llion~ I Treasurer Database Sear_ch_QpJ:iQ!J.s Ckrk&_E.ecordeJ Database Search Options Garfield County_Home~P~ge http://www. garcoact.com/ assessor/parcel.asp ?ParcelN umber=23 93 3 21 003 78 Page 4 of5 11117/2008