HomeMy WebLinkAboutCorrespondenceAndy Schwaller
From: ABH < aspenbuilthomes@gmail.com>
Thursday, June 16, 2016 3:37 PM
Andy Schwaller
Sent:
To:
Cc:
Subject:
David Bartholomew; 'Eric Fisher'
RE: Leyva Residence-Redcliff Circle
Attachments: 6-14-16 Revised Permit Set.pdf; Soils 105772(10-31-0S)S+Flot3FourMileRanch.pdf;
Specifications 12-16-15.doc
Andy, Please review my responses below. I will deliver the Survey and owner authorization letter tomorrow morning.
1. It would appear the structure is too tall to meet the 25 ft. building height limitation. Specifically the existing
grades found at the structure's 4 corners close to grid lines B-2, B-9 and F-2,F-9 on sheet A 3.4 need to be
determined in order to get the average existing grade plane below the principal roof. This horizontal existing
grade plane would then be compared to the horizontal roof grade plane mid-way between the peak and the eve
of the roof. The building height cannot be greater than 25 ft. measured vertically between these two horizontal
planes based on the zoning for this property. We revised all the wall heights to conform the height limits. The
revised elevations pages were submitted to the building department yesterday. I have also attached the
revised plans.
2. A lot specific soils report must be submitted as per the plat notes for this property. See attached
3. An engineer's sealed design of the proposed drainage plan around the structure must be submitted as per the
plat notes. I have requested will deliver asap
4. Sheets A-5.1 and A-5 .2 are referenced in the plan set submitted but not included with the submitted plans.
These pages where never requested from the architect and therefore unavailable. I have attached a copy of the
project specifications where the insulation values are mentioned in section 7.
5. The owner either needs to sign the applications for building and septic or provide a letter allowing the
contractor to sign on his or her behalf. I will deliver this tomorrow
Abdi Pirzadeh, President
Aspen Built Homes Inc.
P .0 Box 3551 Basalt Colorado 81621
Cell 970-618-3555
Office 970-927-0455
www.aspenbuilthomes.com
From: Andy Schwaller [mailto:aschwaller@garfield-county.com]
Sent: Thursday, June 16, 20161:45 PM
To: Aspenbuilthomes@gmail.com
Cc: David Bartholomew <dbartholomew@garfield-county.com>
Subject: Leyva Residence·Redcliff Circle
The following items need to be submitted or clarified before we can complete the building permit review for this
project:
1. It would appear the structure i s too tall to meet the 25 ft. building height limitation. Specifically the existing
grades found at the structure's 4 corners close to grid lines B-2, B-9 and F-2,F·9 on sheet A 3.4 need to be
determined in order to get the average existing grade plane below the principal roof. This horizontal existing
grade plane would then be compared to the hori zontal roof grade plane mid -way between the peak and the eve
1