Loading...
HomeMy WebLinkAboutObservation of Backhoe Pits 07.31.2014l HEPWORTH-PAWLAK GEOTECHNICAL July 31, 2014 Joe Hultquist 402 Munroe Street Rifle, Colorado 81650 joe@young-services.com i Hcpworch·P<\\Yl .1k Gcotcchnic.1l, Inc . 5020 County RoaJ 154 GlcnwooJ Springs, Colormlo 8160 I Ph me: 970 ·945 ·79 88 El\: 970 -945 -8454 crn :ul hpgcnig hpgcotcch.cum Job No. 114 282A Subject: Observation of Backhoe Pits, Proposed Shop Building, Ridge Road near County Road 245 (Buford Road), Garfield County, Colorado Dear Joe: As requested, a represe~tative of Hepworth-Pawlak: Geotechnical observed backhoe pits at the subject site on July 24, 2014 that had been excavated to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were perfo;"Ded in accordance with our agreement for professional engineering services to you, dated July 17, 2014. Evaluation of the hillside cut stability is beyond the scope of this study. Site Conditions: The site is located on an abandoned well drilling pad at the edge of the Grand Hogback past Ridge Road. The northerly sloping terrain has been graded relatively flat by cutting into the hillside and filling some on the downhill side. Bedrock apparently of the Wasatch Formation is exposed in the steep hillside cut to the south. Proposed Construction: The shop will be a steel frame and metal building with a sl ab- on-grade floor at an elevation slightly above the existing ground surface. We assume relatively light to moderate foundation loading supported by paqs and connecting grade beam system. Subsoil Conditions: At the time of our site visit, two backhoe pits located in about the middle (Pit 1) and near the cut face to the southeast (Pit 2) had been dug. The soils exposed in the pits, below about 1 to 2 feet depth of medium dense, clayey gravel with cobbles consisted of weathered and medium hard claystone/sandstone bedrock that extended down to the pit depths of 7 feet. The bedrock was more predominantly weathered claystone in Pit 1 and more predominantly weathered sandstone in Pit 2 . The material was too fractured to obtain undisturbed samples for swell-consolidation testing. Parker 303-84 1-7119 • ColoradoSprings 7 19-633-5562 • Sih-er[home 970-468-1989 . . ' . Joe Hultquist July31, 2014 Page2 Laboratory testing perfonned on a disturbed bulk sample of the weathered claystone consisted of natural moisture content, percent finer than sand size gradation analyses and Atterberg limits with the results provided in Table I. No free water was encountered in the pits and the soils and bedrock materials were slightly moist. Recommendations: Spread footings bearing on the bedrock materials should be feasible for foundation support of the building with some risk of movement. Based on our experience with the Wasatch Fonnation and the medium plasticity of the weathered claystone sample tested, the bedrock may possess a swell potential and the footings should be designed for a minimum dead load pressure. The footings should be designed for a maximum soil bearing pressure of 3,000 psf and a minimum dead load pressure of 800 psf. The expansion potential should be further evaluated at the time of construction. The footings should be a minimwn width of 16 inches for continuous walls and 2 feet for columns. All fill soil and loose disturbed materials in footing areas should be removed and the bearing level extended down to the undisturbed bedrock and the subgrade moistened and compacted. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomaties such as by assuming an unsupported length of at least 10 feet. A perimeter foundation drain should not be needed due to the floor slab-at-grade construction. A minimum 2 feet of imported granular structural fill such as road base should be provided below the floor slab due to the potentially expansive subgrade conditions. Structural fill placed within floor slab areas should be compacted to at least 95% of standard Proctor density at a moisture content at to slightly above optimum. Backfill placed around the structure should be compacted to at least 90% SPD (95% in pavement areas) and the surface graded to prevent ponding within at least 10 feet of the building. Landscape that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within 10 feet of the foundation. Limitations: The recommendations submitted in this letter are based on our observation of the soils exposed within the pit excavations and do not include subsurface exploration to evaluate the subsurface conditions with depth. This study is based on the assumption that soils and bedr~ck beneath the footings and at other areas of the site have equal or better support than those exposed in the pits. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. We should observe the building excavation prior to footing construction to evaluate the exposed materials for foundation support. Job No. 114 282A '( I Joe Hultquist July31, 2014 Page 3 Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH -PAWLAK GEOTECHNICAL, INC. DAY/ksw attachment Table 1, Summary of Laboratory Test Results cc: Albright and Associates -Jack Albright (jack@albri ght-associates.com) Job No. 114 282A HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 Job No.114 282A SUMMARY OF LABORATORY TEST RESULTS SAMPLE LOCATION NATURAL NATURAL GRADATION ATTERBERG LIMITS PERCENT AASHTO MOISTURE DRY GRAVEL SAND PASSING LIQUID PLASTIC CLASSIFICATION SOIL OR PIT DEPTH CONTENT DENSITY NO. 200 LIMIT INDEX BEDROCK TYPE ('Vo) ("/o) SIEVE (ft) (%} (Pct} (%) {%) 1 5-6 4 .5 75 30 16 Weathered Claystone - -