Loading...
HomeMy WebLinkAboutApplication - PermitI Garfield County Building & Planning Department 108 8th Street, Suite #401 Glenwood Springs, Co. 81601 Office:970-945-8212 Fax: 970·384·3470 Inspection Line: 970-384-5003 Building Permit No. I J._~!) . -.. {_ -~ ------------·- Parcel No: 2399-243-00-1 l"f7 ---------------------------------____ 'I(_!_ ____ _ Locality: . ______ ---~ar~~U, Upp_er[Jivide Subd. Exernptioll ... ·---·---·------ Job Address: 7335 CR 313 C..Jf-:-.1 --~-.. -------- Use of Building: .. ____ -------------·· __ _g.ar~ge Owner: Heisel, Gary _ Contractor: Owner Fees: Plan Check: $ 154.21 Septic: Bldg Permit: $ 237.25 Other Fees: Total Fees: $ 391.46 Clerk: C ,-dM~~----Date: I 2 4? 3 4 5 6 7 8 9 10 II GARFIELD COUNTY BU ILDING PERMIT APPLICATION 10 8 8'h St reet, Sui te401, Gl enwood Springs , Co 81601 Phone : 970-945 -8212 I Fax : 970-384-3470 /I ns pection Line: 970-384 -5003 www.!!arfi e ld -countv.com Parcel No: {this in formation is availa ble a t the a ssessors offi r2~ ~cr '4! Z. Lf 3 ~ o-r:> _ ~ \ T i35 Address. (if an :ddres~~ ~ee n;7;ned, pl ease provide C ~ Street Name & C ity) or and legal d esc ripti o n Lot ~ Block No : Subd.~xemm i on ;) U/2P4-ft ~ O'Jl.er: (proJr/ o wner) ''JJ, AL Mailing Adq ess: ~1'15 7 ·avwHLu~ ~~ Ph: q tf> /?b>"<-j Contda{o r: II Mailing Address: , Ph : ,, .--_, \ Architect I Enginee r: Mailing Addre ss: Ph: Sq. Ft. of Bui7~~ Sq. Ft. or Acres of Lot: J$.?~/~d Height: /(f> I Use of Build in g: Jl.. ~0 Describe Work : v Class of Work : ~ o Alt erati o n o Addition Garage: ~c h ed Septic: o Attached o i SDS A lt Ph; t.f 379· Z73 AltPh: I I AltPh: No. o f Flo ors : 1 o Communit y 12 Driveway Permit: z;~.~ Owners val uat ion of Work : $ IZ.ttn~tJ NOTICE A uthority. This a pp licati o n for a Bui lding Permi t mus t be sign ed by the Owner o f the pro perty, described abo\'e, or an authori zed age nt. If the signature below is no t !Jlat of the Owner, a separate leiter of authority, signed by the Owner , mu st be pro vided with thi s Ap pli cati on. Legal Access. A Bui lding Permit ca nn ot be issued without proo f of lega l and adequate acce ss to the property for purposes of in spectio ns by the Buildin g Departme nt. Other Permits. Multiple se parate permits may be required : (I) State Electri ca l Permit , (2) County ISDS Permit, (3) anothe r permit required for use on the property ide n ti fied above , e.g. State or C ou nty Hi ghway/ Road Access or a State Waste water Di scharge Permit. Void Permit. A Bui lding Pe rmit becomes null and void if the work a uthori zed is not commenced within 180 days o f the date of issuance and if work is s us pended or a bandoned fo r a period of 180 days afte r c omme nceme nt. CERT IF ICATION I here by certi fy th at I ha ve read thi s Applicati on and that 01e in for mation contained a bove is true and correct. l und erstand th at th e Building Department accepts !h e Applicati on, alo ng with the plans and specifi cati ons a nd other data s ubmined by me or on my beha lf (submiuals), based u po n my certific ati o n as 10 accura cy. Assumin g completene ss o f the submiuals and approva l of this Ap plicati on, a Building Permit will be issued granting permission to me, as Owner, to construct the stru c ture(s) a nd facilities detail ed on the s ubminals reviewed by the Build ing De partment. In consideration of th e issuance of the Building Permit, I agree that I and my agents will comply with provisio ns of any fed era l, state or loca l law regulating the work a nd the Garfi eld Count y Building Code, ISDS regul ations and a pplicable land use regulations (County Regul ati on(s)). I ac know ledge that the Bui lding Permit ma y be su spended or re vok ed . upon noti ce from the County, if the location, construction or use of the stru cture(s ) and fac ility(ies), described a bove. are not in complia nce with Co unty Regulation(s) or any other applicable law. I hereby grant permission to the Bui lding Department to ent er the propeny, described above, to inspec t the w ork . I further acknowledge that the iss uance of the Building Permit does not pre\'ent the Building Officia l from: (I) requiring the correction of e rrors in the submittals, if any, di scovered after issuan ce; or (2) st o pping construction or use of the structure(s) or fa cility(ies ) if su ch is in violation of County Reg ul ati on(s) or any other applicable law . Revie w of th is Appli cation , i nc lud ing s ubmina ls, and inspections of the work by the Building Department do not constitute an acceptance o f responsibi li ty o r liability b y the Count y of errors, omissions or discrepancies. As the O w ner, I acknowledge that responsibility for compli ance with federa l, state and local laws a nd C ounty Regulati ons res t with me and my authorized a gents. including with o ut limi tati on my architect designer, engineer a nd/ or bui lder. I HER EBY AC KNOW LE DGE THAT I HAVE READ AND UNDERSTAND TH E NOTICE & CERTIFICATION ABOVE: owS~ Z,-2..3~Cj DATE STAFF USE ONLY Sp<d•l Co nd?--7 ?..!; if X jj ~~ • (K) ~f* IBCJ6 ? ~~~~ ro(<ffo~ Adjusted Valuation: Plan C he ck Fee: Permit Fee: Manu h ome Fee: Mise Fees: 41 I '!I tc4 .oo ~ Is'~ .. ~ f ~ ISDS Fee: 4t 3q(~=~, Fees Paid: Balance Due: BP No & I ss u e D ate: ISDS No & Issued Da t e: f'l (~ fLfS -1/ ;)<flo.:~ n ~ 31 I dJ;;;e/ o'j !J/1+- Setbacks: OCC Group: Canst Type: ( Zonjng: BLD~ APPROV;u:--~ ~A TE ~i4~ P~DEPT, ~~ , A~-~ 2/Z&.&rlf- 1/.,S:I?I W: ~tS22 4:;> /P£'-C'-r; R F11A/Yll J r 1 r 1 r 1 r I r I rl I The following items are required by Garfield County for a final Inspection: 1) A final Electrical Inspection from the Col orado State E lectri ca l Inspector. 2) Permanent address assigned by Garfield County Building Department and posted at the structure and where readily visible from access road. 3) A finished roof; a lockable building; completed exterior siding; exterior doors and windows installed; a complete kitchen with cabinets, s ink with hot & cold running water, non -absorbent kitchen floor covering, counter tops and finished walls, ready for s tove and refrigerator; all necessary plumbing. 4) All bathrooms must be complete, with washbowl, tub or shower, toilet, hot and cold mnning water, non-absorbent floors, walls finished, and privacy door. 5) Steps over three (3) risers , outside or inside must be must have handrails. Balconies and decks over 30" high must be constmcted to all IBC a nd IRC requirements including guardrails. 6) Outside grading completed so that water slopes away from the building; 7) Exceptions to the outside steps, decks, grading may be made upon the demonstration of extenuatin g circumstances., i.e. weather. Under such circumstances A Certificate of Occupancy may be is sued conditionally. 8) A final inspection sign off by the Garfield County Road & Bridge Department for driveway installation, where applicable; as well as any final sign off by the Fire District, and/or State Agencies where applicable. A CERTIFICATE OF OCCUPANCY (C.O.) WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. A C.O. MAY TAKE UP TO 5 BUSINESS DAYS TO BE PROCESSED AND ISSUED. OWNER CANNOT OCCUPY OR USE DWELLING UNTIL A C.O. IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use a nd the issuance of a C.O. for the building identified in th e Building Permit. OWNERS SIGNATURE DATE Bappli cationd ecemb er2007 GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS For SINGLE FAMILY DWELLING CONSTRUCTION Including NEW CONSTRUCTION ADDITIONS ALTERATIONS And MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. When reviewing a plan and it's discovered that required information has not been provided by the applicant, this will result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor shall be required to provide this information before the plan review can proceed. Other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. TWO (2) SETS OF CONSTRUCTION DRAWINGS & TWO (2) SITE PLANS MUST BE SUBMITTED FOR ALL APPLICATIONS. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. Any project with more than ten (10) occupants requires the plans to be sealed by a Colorado Registered Design Professional. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following checklist prior to and during design. Applicants are required to indicate appropriately and to submit the completed checklist at time of application for a permit. Plans to be included for a Building Permit, must be on drafting paper at least 18"x24" and drawn to scale. Plans must include a fl oor plan, a concrete footing and fo undati o n plan , e levation s a ll sides with decks, balcony, steps, hand rail s and guard rail s, windows and doors, including the finish grade line and original grade. A section showing in detail, from the bottom o f the fo oting to the top of the ro o f, including re-bar, anchor bolts, pressure treated plates , floor joists, wa11 s tuds and s pacing, in su lation, s hee ting, house-rap , (which is required), s iding or any approved building material. Engineered foundations may be required. A window sche dule. A door schedule. A flo or fra ming pla n , a roof framing plan, roof mu s t be d es igned to withstand a 40 pound p e r square foot up to 7,000 fe et in elevatio n , a 90 M .P.H . wind s peed, wind exposure B or C, and a 36 inch f ro st depth . All s heets to b e identifie d by numbe r and indexed. All of the a bove requirements must b e m et o r your plans will b e returned. All plans s ubmitted must b e incompli an ce with the 2003 lRC. I . Is a si te pl a n included that identifies the location of th e propo sed s tructure or addition and distances to the property lines from each comer of the proposed structure(s) prepared by a licensed su rv eyor and has the s urveyo rs signature and professional stamp o n the drawing? Properti es with slo pes of 30% or greater mu st be shown on the site plan . (NOTE Section: 106.2) Any site plan for the placeme nt of any portion of a structure within 50 ft. of a property line a nd not within a previous ly surveyed building envelope on a subdivision final plat s ha11 be prepared by a lice nsed s urveyor a nd have th e surveyor 's signature and professional sta mp on the drawing. Any structure to be built within a building enve lope o f a lot s hown on a recorded s ubdivi s ion plat shall include a copy of the buildin g env e lope as it is shown o n the final plat with the proposed structure located within th.e 7 nvelope. Yes v ---- 2. Does the site plan also include a ny other buildings o n th e property, setback easements and utility easements? Please refer to Section 5.05.03 in the Garfield County Zoning Resolution if the property yo7a e app lyin g fo r a building permit o n is locate d on a comer lot. Special setbacks do apply. Yes ----- 3. Does the site plan include when applicable the location of th e I.S.D.S. (Individual Se wage Di s posal System) and the di stances to the pro perty lines , wells (on subject property and adjacent properties), streams or water courses? Yes N {fr 4. Does the s ite pla/i dica te the location a nd direc tion of the County o r private road access ing the property? Yes ------ 2 5. Have you provided any RESOLUTIONS and/ or LAND USE PERMIT(S) associated with this property? Yes ______ if Yes please provide a COPY. No __ /.1 _______ _ 6. Are you aware that prior to submittal of a building permit application you are required to show proof of a legal and adequate access to the site? This may include (but is not limited to) proof of your right to use a private easement/right of way; A County Road and Bridge permit; a Colorado Dept. of Highway Permit, including a Notice to Proceed; a permit from the federal government or any combination. You can contact the Road & Bridge Department at 625-860 I. See phone book for ~~;ragen~ p~~ ~t~+-~ 7. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the IRC or per stamped engineered design? Yes ~ 8. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ~ No ------ 9. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes ------No ____ _ I 0. Do the plans include design loads as required by Garfield County for roof snow loads, (a minimum of 40 pounds per square foot up to & including 7,000 feet above sea level), floor loads and wind loads? 5o !h l:?z.oF ~ Yes ~ I I. Does the plan include a building section drawing indicating foundation, wall, floor, and roof construction? Yes V 12. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes ~ 13. Does the building section drawing or other detail include the method of positive connection of all columns and~s? Yes _______ _ 14. Does the elevation plan indicate the height of the building or proposed addition from the undisturbed grade to the midpoint between the ridge and eave of a gable or shed roof or the top of a flat roof? (Building height measurement usually not to exceed 25 feet) Yes ~ 3 15. Does the plan include any stove or zero c learance fireplace planned for in sta ll ation including make and model and Colorado PhaseJ-1 certifications or phase II EPA certification? Y~ No ~ ------- I 6 . Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the IRC? Yes No -------------- 17. Does the p lan include a window schedu le or other verification that egress/rescue windows from sleeping rooms ~nd/or basements comply with the requirements of the IRC? Yes ._/ ------- 18. Does the plan include a window schedule or other verification that windows provide natural li g ht and ventilation fo~ll habitable rooms? Yes r/ -------'---- 19 . Do the plans indicate the locati on of g lazi ng s ubj ect to human impact such as glass doors, g lazin g immediately adjacent to such doors; g lazin g adjacent to any surface normally used as a walking surface; sl iding glass doors; fixed glass panels ; shower doors and tub enclosures and specify safety ~:ing for these area~o __ iJ....[{_fr ____ _ 20. Is the locati on of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? ~ 1 { Yes IV f'C 21. Do you understand that if you are building on a parcel of land created by the exemption process or the subdiv ision pJ:ffi;ess, are building plans in compliance with all plat notes and/or covenants? Yes V ------ 22. Do you understand that if you belong to a Homeowners Association (HOA), it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? The building permit application will be accepted without it, but you run the ri sk of the HOA bringing action to enforce the covenants, which can result in revocation of permit issued. Additionally, your Plan Review fee is not r efundable if the plans have been reviewed by the Building Department prior to any action by the HOA that requires either revocatio'} W substantia l modification of the plans. Yes fV !f\ 23 . Will this be the J1y r esidential stru·h.Jt on the parcel? ~ Yes :J No ~" lfno-Explain:--=~=---ft---- 24. Have two (2) comylete sets of construction drawings been submitted with the application? Yes V ------- 4 25. Do you understan<!Jhat the minimum dimension a home can be on a lot is 20ft. wide and 20ft. long? Yes Y ------ 26. Have you designed or had this plan designed while considering building and other construction code requirements?/ Yes V ---'------- 27. Do your plans comply with all zoning rules and regulations in the County related to your properties zone district? / Yes v -------- 28. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes t/ 29. Do you understand that approval for design and/or construction changes are required prior to the application ofmthee~s changes? Yes 1/ -------"'::....._- 30. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application submittal and that you will be required to pay the "Permit Fee" as well as any "Road Impact" or_;8eptic System" fees required, at the time you pick up your building permit? Yes ~ ----- 31. Are you aware that you must call in for an inspection by 3:30 the business day before the requested inspection in order to receive it the following business day? Inspections will be made from 7:30a.m. to 3:30 p.m. Monday through Friday. Inspections are to be called in to 384-5003. / Yes v No ------ 32. Are you aware that requesting inspections on work that is not ready or not accessible will result in a $50.00 re-inspectipn fee? Yes ~ ------ 33. Are you aware that you are required to call for all inspections required under the IRC including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? / Yes ------ 5 34. Are you aware that the Permit Application must be signed by the Owner or a written authority being given for an Agent and that the party responsible for the project must comply with the IRC? Yes t/ 35. Do you understand that you will be required to hire a State of Colorado Licensed Electrician and Plumber to perform installations and hookups, unless you as the homeowner are performing the work? The license number of the person performing the work will be required at time of applicable inspectio.9 Yes t/ --------~--------- 36. Are you aware, that on the front of the Building Permit Application you will need to fill in the Parcel/Schedule Number for the lot you are app lying for this permit on prior to submittal of a building permit application? Your attention in this is appreciated. Yes / 37. Do you know that the local fire di strict may require you to submit plans for their review of fire safety issues? Yes / (please check with the building department about this requirement) 38. Do you understand that if you are planning on doing any excavating or grading to the property prior to issuance of y-building permit that you will be required to obtain a grading permit? Yes ~ ----~--- 39 . Are you aware that if you will be connecting to a public water and/or sewer system, that the tap fees have to be paid and the connections inspected by the service provider prior to the issuance of a Certificate of)Jccupancy? Yes / -------"------ 40. If you anticipate obtaining a water tap from the City of Rifle, please provide a letter indicating that the City will provide water service. No building permit application will be accepted without such a letter. Yes I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. Signature be~ Date Phone:_--"-g_7_9_Z-_7_~-~-'-----( days); _q_V---=' ?;____;G::.....;.~_5_;_i ____ ( evenings) 6 Project Name: kcr=--:- Project Address: .377~ ~ l!13 t3 ?33_5 Notes: If any required information is missing delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit. Jf it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes, the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. bpminreqsfJan2009 7 GARFIELD COUNTY BUILDING REQUIREMENTS Codes: 2003 IRC, IBC, IFGC, IMC, IPC, Setbacks: Check subdivisions and zone district for setback requirements. Snow load (measured at the roof): 40PSF up to 7000ft. elevation. Seismic design category: B SOP SF 7001 to 8000ft. 7 5PSF 8001 to 9000ft. lOOP SF 9001 to lOOOOft. Weathering probability for concrete: Severe Termite infestation probability: None to slight Wind speed: 90mph Decay probability: None to slight Wind Exposure: B or C (see section R301.2.1.4) Frost Depth: 36in. to 8000ft. elevation. 42in. 8001 and above. Winter Design Temperature: Minus 2 to 7000ft.; minus 16 over 7000ft. elevation. Air Freezing Index: 2500deg F-days to 7000ft.; over 7000ft. to be determined by Building Official. Ice shield under-layment required. Mean Annual temp.: Variable Insulation: Maximum glazing U factor: 0.50 Minimum R-Values: • Ceilings/roofs R values are: R-30 stick built structures. R-38 Jog construction and steel rafter construction. • Walls R values are R-19 wood frame; R-19 cavity R-3 sheathing steel studs. • Floors R-values are R-19. • • • Basement wall R-values are R-10 beiow grade, R -19 above grade. Slab perimeter R-value and depth is R- 10/36in. Crawl space wall R-values are R-10 below grade and R -19 above grade If floors over crawl spaces are not insulated, the crawl space walls must be insulated. Basement wall must be insulated to frost depth. Common walls garage to house must have R-19 insulation. Common ceiling/floor garage to house must have R-19. Take precautions to protect plumbing in these areas. COUNTY OF GARFIELD-BUILDING DEPARTMENT CORRECTION NOTICE 108 8th St., Suite 401 ~lenwood Springs, Colorado Phone(970)945-8212 Job located at '-:;,;(_ 3/ 3 Permit No. / (} £(/z 7 I I have this day inspected this structure and these premises and found the following corrections needed: , I 0 Call for Re-lnspection 0 $50.00 Re-lnspection Fee must be paid prior to Re-lnspection You are hereby notified that the above correction must be inspected before covering. When correction(s) have been made, call for inspection at 970-384-5003. Date 6 -9' 20 e_.;) 25 Building Inspector --"'~~d;::;~~~:~~Ct~U~.:...--::~L·d&~;...&~-e~~----­ Phone (970) 945-8212 11237 No. __________________ ___ Assessor's Parcel No. 2399-243-00 -117 Date _____ 21_2_6_12_0_0_9 __ _ BUILDING PERMIT CARD Job Address 7335 CR 313 Silt Owner Heisel, Gary Contractor Owner Setbacks: Front Rear garage Soils Test f}g Footing 3-..3---~ 9. Foundation 0_. 3·1 &i1/i Grout ________ ~------- Underground Plumbing ..::~--'-7---"'----· Rough Plumbi?:~ ~~ Framing lj_-z-oq f1:::?nl Insulation --yu(,_ Roofi ng -----=-:::--~--------------- Drywall "?1-A- Gas Piping ~tt...- Address 0187 Fairway Ln. GWS Phone # 970-945-6654 Address same as owner Phone # 970-379-2734 RH LH Zoning INSPECTIONS NOTES / Weatherproofing------------------------- Mechanical ____ ~ __ --=c. ____________________ _ Electrical Rough (State) ----'-==J'=-7' .... 9-:tzL...b---------- EiectripfSI Final (State) ______ '-____ "JA--:-:-:..- Final '1~z-vcr /Checklist Completed? ~ Certif(cate Occupancy # ~Q'2.Y~. . 0 Date \~>\/:., t-\ ) L\J..Q .Q I Septic System # _________________ _ Date --------------------Final ________________________ __ Other ____________________________ _ (continue on back) ParcBI 0Btail PagBiuf3 Garfield County Assessor IT reasurer Parcel Detail Information AssessQr[fre_asurerJroperty Search I Assessoc SubsetOu_ery I ~_s_sessor Sales Sear~b Clerk B Recorder Reception Search Baste Building Char<lctecistic~ I T<lxlnformation Parcel Detail I Value_Oetail I Sales_lletail I R_esidentLai/C[J_mmercjallnmiJ]\I!LrnenLDetail land D~ta_ll I Eh_otog['[!p_h~ I Mill_leyy_R_evenues_O~t<lil I Tax Area II Account Number II Parcel Number 112[)[)8 Mill levy I I 023 II R045416 II 238824300117 II 46.355 I l1wner Name and Mailing Address !HEISEL. GARY H LINDA 1187 FAIRWAY LANE !GLENWOOD SPRINGS. CO 81601 Assessor's Parcel Description (Nono be used as a legal description) ISECT.TWN.RNG:24-7-81 DESC: A PARCEL IDF LAND IN THE swsw SEC 24. AKA !PARCEL I -UPPER DIVIDE !SUBDIVISION EXEMPTION PRE:RD23375 IPRE:R230815 RECPT:748246 IRECPT:746886 BK:I874 PG:IS8 IRECPT:713204 BK:I874 PG:IS6 IRECPT:713203 BK:0885 PG:0750 http:! I www.garcuact.cum/ asssssur /Parcsl.asp? AccuuntNumbsr=R04S41S I I I I I I I I I I I 2/23/2008 Parcel Detail IIBK:D816 PG:D315 BK:D813 PG:DD45 II location Physical Address: I Subdivision: I land Acres: 1115.581 I land Sq Ft: I D Section II Township II Range I 24 II 7 II 91 I 2[][]8 Property Tax Valuation Information II Actual Value II Assessed Value I I land: 54.53oll I Improvements: oil I Total: 54.53oll Additional Value Detail ~----------------- Most Recent Sale •li======Sa=le =Dat=ie: I I Sale Price: I Additional Sales Detail Basic Building Characteristics Number of Residential lo Buildings: Number of Comm/lnd lo Buildings: http:! I www.garcoact.com/ assessor /Parcel.asp? AccountNumber= RD45416 4.3401 ol 4.3401 I I Page 2 of 3 2/2312DDS Parcel Detail No Building Records Found Tax Information Tax Year II Transaction Type II Amount I 2oo8 II Tax Amount II $2o1.2o1 Io~ ofEage ~~sesso r Oatabi! se_ S~accJLDRtLons I Ir~il_surer 0 a_1:_ab9J>Il_~EHlf'ch Optign~ Clerk o Rer:ocder DatabaseSil_archDptions Garfield County_Hom_eP_age Page 3 uf 3 The Garfield County Assessor and Treasurer's Offices make every effort to collect and maintain accurate data. However. Good Turns Software and the Garfield County Assessor and Treasurer's Offices are unable to warrant any of the information herein contained. Copyright @J 2005 -2008 Good Turns Software. All Rights Reserved. Database o Web Design by Goo_dlurns_Softwa_['!J. http:! I www.g arcuact.cum/ asses sur /Parcel.asp? AccuuntNumber= RD4541S 2/2312008 [ COtJCRGT!O LAP :::::r:::: ' :..---::.--sIll till(, ------, // -....._ ~ / / -.. ~-------, f-=1--f-' ~ DO ~ f-· -. +-~~~ f- f--'---• .---DO· f: L f-- ... r -• L> ------- 7b '(EAL A St ~At-1' s~ '"'"t.e$ f ·~ js I' ICE S,~I!::LP "--._ -....._ /¥. '6 FA C.IA ~ l-_ _ r COIJTI>IOO~ 1£!>11" ' - ---- I ,__ ---- ----1-·- ., 4 \) El:rl u.. I 'B~ o.c . . rJ.. 5 1"(<)';$ C.UV$ ~ .?-KI Z. H EAP!'t~ c. o! ~ s" s n; "' ll.)lw- 'l '• -zd' r-oorell. z:'A ~ ~tiiP£ ' ,,, a:s ~ - 111/HJt)fh CTtl !!-E f) fi..fl/ G 11./ 1: t. ~f.: P Fl?IJS~tS z.q." OC- /j o( f !8 = J.. . - . Lt.FT - . • DO , APPROVED SUIIJECr TO NOTt:D EXCEPTI:ONS & INSPECTIONS GARFIELD COUN1Y BUILDING DEPARTMENT Date :?/MI-n By=~:>~!?::___ FIELD COPY NO lNSPECfiON Wl'rHOUT TIIE8E PLANS ON SITE page of 1350 ~~~------------~-6b'------------------~-------~' / . '2._-'L;< 12. 21?/ \1 ! .d\Y :2-1'5"1-VL t;ADEe ~ . q'o':~-ll'' o' S'o' ' i::,z2k7 UPPER. P\VIPE" 5U~PIVIS"Jll!V &: )I.E/J\PTIDtU R. IOC. EP:Vi~ IIJ"'> 7% 'IO.if- # • :1-VPR~() PI'/1/')G:' L-i-C f'ft~e..e'".,. <:. 3Cl"' ~z~ "01>~ CJC!S' ,, I ==Ito' \ "