Loading...
HomeMy WebLinkAboutPlansMAINTENANCE BUILDING FOR MRI 1 058 COUNTY ROAD 1 00 GARFIELD COUNTY, COLORADO NOTES 1. Structural engineering for prefabricated steel building provided by Sentinel Building Systems, Albion, Nebraska. 2. Foundation structural engineering provided by Westar Civil and Structural Engineers, Rifle, Colorado. 3, Contractor shall coordinate the location of openings. drains, inserts, depressions, etc. with architectural, mechanical and electrical requirements. 4. Contractor shall check and verify all dimensions and details shown on structural drawings with those shown on architectural drawings, and with existing field conditions. 5. Contractor shall notify the Architect of any discrepancies between architectural and structural drawings and receive written clarification before proceeding with work, 6. Changes to the structural drawings required due to acceptance of alternates and/or substitutions are the responsibility of the Contractor and shall be submitted to the Structural Engineer for approval. 7. Location of windows, doors, exhaust fans and other penetrations shall be verified in the field and may be adjusted to conform to the wall and roof panel layout. 8. Site preparation, excavation, compaction, preparation for placing concrete footings and slabs, backfilling, underdrain system and all other design recommendations shall be in accordance with the Soils Engineer's inspection and recommendations. PROJECT DESCRIPTION OCCUPANCY: S-1 (MOTOR VEHICLE REPAIR GARAGE) S-1 (STORAGE) B (OFFICE) TYPE OF CONSTRUCTION: TYPE II - B (NON-SPRINKLERED) PROPOSED BUILDING AREA: S-1 (MOTOR VEHICLE REPAIR GARAGE) S-1 (STORAGE) B (OFFICE) LOT AREA: 95.333 ACRES GENERAL NOTES 11088 S.F. 720 S.F. . 720 S.F. 1. ALL WORK SHALL CONFORM WITH ALL GARFIELD COUNTY CODES AND ORDINANCES, AND THE LATEST ADOPTED EDITIONS OF THE INTERNATIONAL BUILDING CODE REQUIRE EXIT OCCUPANT LOAD / 720 S F / 100 SF PER OCCUP = / 8 OCCUPANTS coie- 1 B Oa- '11-047Atiric\e/ 4M -A, L 11.0 ol REQUIRED E Tr' '17ki4 76) Yi.SP174)-14 41 a' 1" (9. K 1 it,1/401 SECOND FLOOR t:16 CODE REVIEW PLAN 1" = 1 O' -O" 4syy-- 4c, ,4.41 EQUI RED EXIT/ OCC 8A0SF/10 90 PANT LOAD SF PER OCCUP = CUPANTS REQUIRED EXIT NC O\5� OCCUPANT LOAD 2061 S F / 300 SF PER OCCUP = 7 OCCUPANTS V OCCUPANT LOAD 505 S F / 300 SF PER OCCUP - 2 OCCUPANTS REQUIRE{ \ EXT -7 3 -HOUR FIRE WALL WI 3 -HOUR RATED DgpRS & `ALL PENETRATIONS AND JOINTS SEALED WITH APPROVED FIRE STOP SYSTEM t 1 OCCUPANT LOAD 3799 S F / 100 SF PER OCCUP = 38 OCCUPANTS REQUIRED EXIT 17 OCCUPANT LOAD 3785 S F / 100 SF PER OCCUR = 38 OCCUPANTS 3 -HOUR FIRE WALL W/ .),,-HOUR RATED DOORS' ALL PENETRATIONS' AND JOINTS SEALED WITH APPROVED FIRE STOP SYSTEM REQUIRED EX T REQUIRED FxIT 1 N I, i V i 1 REQUIRED EXIT C2) NOTE SEE CODE REVIEW REPORT BY GA,I DATED MARCH 30, 2016 • .1 .. FIRST FLOOR COD E REVIEW PLAN 1" = 10'-0" • CH COPYRIGHT 2016 - GARNER ASSOCIATES. INC. i GARNER ASSOCIATES, INC_ ORPORA' 1 FD ARCHITECTURE AND PLANNING Harry Garner Registered Architect 4181 County Road 311 New Castle, CO 81647 970-876-2210 CELL 970-379-8'345 E-mail: ¥amer_harry.(a)msn.com Web site: gaiassoclates.rum I , 1 I, r 4 '., un .0.1 'i 1 .,, t,T,!,ii..,,M M [:.1 , ZrT \, 4 T' .i iiiii z L_ ^ 0 0 i.1 1 ,., Ei•U,,,,, h id rl v U P 44 ,h .......„ ANe j oto I • O HARRY A. GA E $ 4'3057 9/1' i�,o o ti.\( ' \ ) ‘ (if 1 t,`; RC` de REVISIONS JOB NUMBER 1409 DATE 10-20-14 DRAWN BY CHECKED BY it SHEET NUMBER DOOR SCHEDULE ALL DOORS STEEL UNLESS NOTED OTHERWISE. ALL DOOR FRAMES SHALL BE HOLLOW METAL UNLESS NOTED OTHERWISE U -FACTOR FOR ALL EXTERIOR DOORS = .35 TYPE/ OPER. MARK WIDTH HEIGHT FIRE RATING REMARKS WI N D OW SCHEDULE (SEE ELEVATIONS FOR LOCATIONS OF TEMPERED GLASS) U -FACTOR FOR ALL WINDOWS = .35 AIR INFILTRATION FOR ALL WINDOWS = .3 CFM/SF WINDOWS SHALL BE VINYL WINDOWS SUPPLIED BY BLDG MANUFACTURER MARK OPER. NOMINAL WIDTH HEIGHT REMARKS A HORIZ SLIDER 4'-0" 4'-0" (11, w U U w B 01 HINGE 3'-0" 7'-0" NR 02 HINGE a -o" 7'-0" NR 03 HINGE 3‘...0" 71-0" NR I 04 HINGE 3'-0" 7-0" NR 05 HINGE 3'-0" 7'-0" NR INSULATED, AIR INFILTRATION = .5CFM 06 HINGE 3'-0" 7'-0" NR INSULATED, AIR INFILTRATION = .5CFM 07 HINGE a -o" 7'-0" NR INSULATED. AIR INFILTRATION = .5CFM 08 HINGE 3'-0" 71-0" NR INSULATED, AIR INFILTRATION = .5CFM 09 HINGE 3-0" 7'-0" NR INSULATED, AIR INFILTRATION = .5CFM 10 HINGE 3'-0" 71-0" 3 -HR 11 HINGE 3'-0" 7-0" 3 -HR 1 12 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 13 OHD 12-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 14 OHD 121-0" 16-0" NR SECTIONAL OHD, SEE ELEVATIONS 15 OHD 12-0" 161-0" NR SECTIONAL OHD, SEE ELEVATIONS 16 OHD 121-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 17 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 18 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 19 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 20 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 21 OHD 12'-0" 16'-0" NR SECTIONAL OHD, SEE ELEVATIONS 22 OHD 121-0" 161-0" NR SECTIONAL OHD, SEE ELEVATIONS 23 HINGE 3'-0" 7.-0" NR 24 HINGE 4'-0" 7'-0" NR PAIR EA 2'-0" WIDE 25 HINGE 3'-0" 7-0" NR _ WI N D OW SCHEDULE (SEE ELEVATIONS FOR LOCATIONS OF TEMPERED GLASS) U -FACTOR FOR ALL WINDOWS = .35 AIR INFILTRATION FOR ALL WINDOWS = .3 CFM/SF WINDOWS SHALL BE VINYL WINDOWS SUPPLIED BY BLDG MANUFACTURER MARK OPER. NOMINAL WIDTH HEIGHT REMARKS A HORIZ SLIDER 4'-0" 4'-0" (11, w U U w B HORIZ SLIDER 61-0" 31-0" JOB 1409 DATE 10-20-14 DRAWN CHECKED i , NUMBER BY BY SHEET NUMBER A• 1 ROOF RIDGE T. 0. PURLIN g EAVE T. 0. SLAB ROOF RIDG T. 0. PURLI EAVE T. 0. SLAB rI Mil j I I I I I • 1.1 co 3 SOUTH ELEVATION 1/8" = 1'-0" 1 25 GA R -PANELS ON PURLINS WI R-40 VINYL FACED METAL BUILDING BATT INSULATION INSTALLED PER MANUFACTURER'S REQUIREMENTS 26 GA R -PANELS ON Z-GIRTS Wi R-19 VINYL FACED METAL BUILDING BATT INSULATION INSTALLED PER MANUFACTURER'S REQUIREMENTS • T-1 1-1 1-1 WEST ELEVATION 1/8" = • NORTH ELEVATION 1/8" = EAST ELEVATION 1/8" = COPYRIGHT 2016 - GARNER ASSOCIATES, INC. ARCHITECTURE E-mail: GARNER ASSOCIATES, INCORPORATED AND Harry Gamer Registered Architect U 4181 County Road New Castle, CO 970-876-2210 CELL 970-379-8345 garner_harry@msn.com Web site: gaiassociates.com U )04. v 4 ,.. ...i rJ O Ti I PLANNING 311 81647 (11, w U U w arro-orCOL k1 iZt. II Pr - 0/ 0 .0 HARRY A. GARNER 0 $, ( 3057* , - $ ' 4-• • er,6 , ( , or c '-" C. 41, R....''' %....4.- b-)7 1 te REVISIONS JOB 1409 DATE 10-20-14 DRAWN CHECKED i , NUMBER BY BY SHEET NUMBER A• 1 I 1 ! T 1 11 _ T I L , , , 1 , , , 1 ,..._ . , , _ I I I 1 1 1 1 , 1 1 1 , .1 ___ ____ ___ T-1 1-1 1-1 WEST ELEVATION 1/8" = • NORTH ELEVATION 1/8" = EAST ELEVATION 1/8" = COPYRIGHT 2016 - GARNER ASSOCIATES, INC. ARCHITECTURE E-mail: GARNER ASSOCIATES, INCORPORATED AND Harry Gamer Registered Architect U 4181 County Road New Castle, CO 970-876-2210 CELL 970-379-8345 garner_harry@msn.com Web site: gaiassociates.com U )04. v 4 ,.. ...i rJ O Ti I PLANNING 311 81647 (11, w U U w arro-orCOL k1 iZt. II Pr - 0/ 0 .0 HARRY A. GARNER 0 $, ( 3057* , - $ ' 4-• • er,6 , ( , or c '-" C. 41, R....''' %....4.- b-)7 1 te REVISIONS JOB 1409 DATE 10-20-14 DRAWN CHECKED i , NUMBER BY BY SHEET NUMBER A• 1 GYP BOARD — 24'X48' MIRROR PAPER TOWEL.. DISPENSER a in C" REP WAINSCOT W/TRIM TOILET TISSUE DISPENSER 4' RUBBER BASE GYP BOARD PAINTED REP WAINSCOT W/TRIM 4' RUBBER BASE J 0 N- 36' LONG 1 1/2' DIA, GRAB BAR 18' LONG 1 1/2' DIA. VERTICAL GRAB BAR 42' LONG 1 1/2' DIA. GRAB BAR 0 9 H/C TOILET - SOUTH ELEV 1 /4" = 1'-0" 3,-4" 18' LONG 1 1/2" DIA, GRAB BAR 36' LONG 1 1/2' DIA, GRAB BAR 42" LONG 1 1/2' DIA. GRAB BAR TOILET TISSUE DISPENSER H/C TOILET - SOUTH ELEV 1/4" = 1'-O" 36' LONG 1 1/2' DIA, GRAB BAR TOILET TISSUE DISPENSER 42' LONG 1 1/2' DIA, - GRAB BAR N PAPER TOWEL DISPENSER r ' 24'X36" MIRROR z O LO 4'-5 1/4" rI 0 ENLARGED H/C TOILET PLAN 1/4" = 1'-0" STAIRWAYSEE 1/A1.1 FOR DETAIL. 21 RISERS @ 6.86" +/- EA 20 TREADS @ 11" EA OFFICE 4" POURED CONCRETE OVER METAL DECK. SEE SENTINEL DRAWINGS PAGES 20-22 FOR SECOND FLOOR FRAMING AND SHEETING 6-7 z 0 U, F z W 4-C" 6-0" 6-0" (A) (1°‘ (A) SECOND FLOOR PLAN 1/8" = 1-0" 1 1/4" DIAMETER PIPE HANDRAIL W/ METAL HANDRAIL BRACKETS (c 32" O.C. PROVIDE SOLID BACKING @ EA BRACKET. EXTEND HANDRAIL 12" BEYOND TOP AND BOTTOM OF STAIR NOSINGS AND RETURN TO WALL 1X WOOD WALL CAP @ PARTIAL WALL 2X4 STUD WALL W/ GYP BOARD EA SIDE HANDRAIL TO BE CONTINUOUS FROM THE EXTENSION @ THE BOTTOM OF THE STAIR TO THE EXTENSION AT THE TOP OF THE STAIR 1X WOOD TREAD W/ 3/4" DIA. NOSING 1X WOOD RISER GENERAL NOTES FOR STAIR DETAIL: 1. STAIRS SHALL COMPLY W/ REQUIREMENTS 2009 IBC SECTION 1009. 2. GUARDRAILS SHALL COMPLY W/ 2009 IBC SECTION 1013. 3. WRAP ALL EXPOSED WOOD WITH 5/8" TYPE X GYP BOARD EXCEPT WOOD TREADS AND RISERS. 1'-0" CD EQUAL TREAD WIDTH SEE FLOOR PLAN FOR WIDTH & NUMBER HEIGHT OF PARTIAL WALL ABOVE NOSING HEIGHT OF RAILING ABOVE N • : NG 2X16 WOOD STRINGER @ EACH WALL & @ CENTER OF STAIR WIDTH. CC ed • wu_ Q COWZO111 � H/C TOILET - SOUTH ELEV 1/2" = 1'-O" 29 GA STEEL PRO -PANEL SIDING 8" Z-GIRTS-SEE SENTINEL WALL FRAMING ELEVATIONS FOR SIZE AND SPACING R-19 VINYL FACED FIBERGLASS BATT INSULATION @ EXTERIOR WALLS I WALL TYPE 2 NON -FIRE RATED 29 GA STEEL PRO -PANEL SIDING 8" Z-GIRTS-SEE SENTINEL WALL FRAMING ELEVATIONS FOR SIZE AND SPACING R-19 VINYL FACED FIBERGLASS BATT INSULATION 25 GA STEEL FURRING CHANNEL @ 24" O.C. VERTICALLY W/ 5/8" TYPE X GYP BOARD INSTALLED HORIZONTALLY TAPED, TEXTURED, PAINTED WALL TYPE 3 NON -FIRE RATED 3-1/2" 26 GA METAL STUDS @ 24" 0.C. VERTICALLY W/ 5/8" TYPE X GYP BOARD INSTALLED HORIZONTALLY EA SIDE TAPED. TEXTURED, PAINTED WALL TYPE 4 NON -FIRE RATED 6" 33 MIL METAL STUDS @ 12" O.C. VERTICALLY W/ 3 LAYERS 1/2" TYPE X GYP BOARD EA SIDE: BASE LAYER - APPLIED PARALLEL W/ 1" TYPE S DRYWALL SCREWS @ 36" O.C. SECOND LAYER APPLIED PARALLEL W/ 1-5/8" TYPE S DRYWALL SCREWS @ 12" O.C. FACE LAYER: APPLIED AT RIGHT ANGLES W/ 2-1/4" TYPE S DRYWALL SCREWS @ 12" O.C. AND 1-1/2" TYPE G DRYWALL SCREWS @ 24" O.C. MIDWAY BETWEEN STUDS AND 1-1/4" ABOVE AND BELOW HORIZONTAL JOINTS. STAGGER JOINTS 24" EACH LAYER AND SIDE. TAPE, BED, TEXTURE, PAINT FACE LAYER EA SIDE GYP BOARD SHALL BE FROM ONE OF THE MANUFACTURERS LISTED IN GA FILE NO. WP 2922 FURR EACH FACE OF STRUCTURAL W/ 1-5/8" STEEL STUDS @ 12" O.C. AND CARRY THE 3 LAYERS OF GYP BOARD TO THE UNDERSIDE OF THE ROOF DECK. FIRE CAULK ALL JOINTS BETWEEN WALL AND EXTERIOR WALL AND ROOF PANELS. ALL PENETRATIONS SHALL BE SEALED W/ AN APPROVED FIRESTOP SYSTEM. WALL TYPE 5 3 -HOUR FIRE RATED GA FILE NO. WP2922 WALL TYPES 1/2" = 1'-0„ 144-3' 8" THICK REINFORCED CONCRETE APRON BURIED FRESH WATER HOLDING TANK 24-0" 24-0" 24-0" 24'-0" 24'-0" 24-0" 35 -8' 12'-0" 12-4" 6-,0' 2 4' 3'-4 3,4' 12'-4" 5-10" 12'-4" 1 1r2." 3'-8 112' 2-10" 12'-4" 8-1C' 03) ([3) (B) AIR INTAKE GRILE MOUNTED N R CEIL G 3URIED OIL NTERCEPTER ' THICK REINFORCED CONCRETE APRON (B) W 0- -J W z z W co W a >- H • j WALL TYPE 2 (SEE SEN NEL PAGE 1 WASH BA 10' X 3' FLOOR DRAIN W/ CAST IRON GRATI SLOPE CONC SLAB -T DRAIN 1/4" PER 1'-0" W l < Q 0- C•1 N z O H a. J W z H z W U) N W 0_ ›- /- - J I— J J 0" ,0 AC CONDENSER <A> �0 0 -J w z F- z W WALL TYPE 1 22 ,I, ;• WALL TYPE 2 (SE AIR INTAKE GRILLE MOUNTED NEAR CEILING 6" SCHEDULE 40 DRAIN LINE -- SENTINEL PARTITION 1 - PAGE 23) DELIVERY w WALL TYPE 3 (SENtIN "HOTSY' UNIT AIR MPRESS OR 6" SCHEDULE 40 DRAIN LINE SEE ENLARGED PLAN THIS SHEET FOR `°1-1/t TOILET LAYOUT. TOILET 2 SIM EXCEPT GRAB BARS NOT REQUIRED. PROVIDE BIi.00KING IN WALLS FOR ADIDITION OF GRAB BARS IN FUTURE. TITI 14 4 - SEE PAGE 26) FAU 24 C H/C TOI LEf /4 TOILET C 2 M J 8'-6 3/4" LL TYPE 4 r -5" STORAGE i'-8 1/4" GAS METER --------- BURIED SEPTIC HOLDING TANK 6-2" LL TYPE 3 6-0" EE SENTINE w W W M z 0 H H a w' z z W STAIRWAY TO ECOND FLOOR. SEE 3/A1.1 FOR DETAIL. I 21 RISERS @ I6.86" +l- EA 20 TREADS @ 1 I " EA PAGE 17) 2-10' 3'-8 1/2' (A) <A) (A) SENTINEL TYP WINDOW FRAMING - SEE PAGE 27 12'-4 1 WIND BENT - SEE SENTINEL DRWG 13 WALL TYPE 5 100,000 BTU GAS FIRED INFRARED HEATER ABOVE EXHAUST FAN MOUNTED NEAR CEILING 5-10 5-10" 10" X 15-0" FLOOR DRAIN (TYP 4' WALL T YPE 1 (SEE ENTINEL PA 6" SC EDULE 40 DRAIN LINE MAINTENAN BAY 1 \ 200,000 BTU GA9� FIRED INFRARED HEATER ABOVE i` (TYP 4L 12'-4" EXHAUST FAN MOUNTED NEAR CEILING\ 5-10. E 06 T 3'4' 14, 12'-4" WALL E 18) -Ij WIND BENT - SEE SENTINEL DRWG 13 (B) WALL TYPE 5 6" SC -I EDULE 40 DRAI� _INE 11 7 YPE 1 (SEE SENTINEL PA 3-10' 5-10" I II 11111111111111111111111111111111111 17 AIR INTAKE GRILLE MOUNTED NEAR CEILING 4" SC-IEDJLE 40 DRAILIME AINTONANQE BA 2 E 17) 12-4" EXHAUST FAN MOUNTED NEAR CEILING S--8 1 7-10" 12-4" 6 0' 2'-1 1'7 WIND BENT - SEE SENTINEL DRWG 12 <B> 2 <B> 8" THICK REINFORCED CONCRETE APRON 2'-1 12" WIND BENT - SEE SENTINEL DRWG 11 (B> 0 t:._FIRST FLOOR PLAN 1/8" = 1'-0" COPYRIGHT 2016 - GARNER ASSOCIATES, INC. GA, GARNER AS SOCIA GES, INCORPORATED ARCHITECTURE AND PLANNLN(; Harry Garner Registered Architect I 4 181 County Road 311 New Castle, CO 81647 970-876-2210 CELL 970-379-8345 E-mail: garne.r_harry(p)msn.com Wet-) site: gaiassociates.roIn I r 0 U M REVISIONS JOB NUMBER 1409 DALE 10-20-14 DRAWN BY CHECKED BY SHEET NUMBER Ai.1