HomeMy WebLinkAbout3.0 Water Quality Control DataWater Quality Control Division 4300 Cherry Creek Drive South, 82
Denver, Golorado 80246-1530
GDPH E.WQEnqReview@state.co.us
303-692-6298
Engineering Section
Colorado Department
of Public Health
andEm'ironment
and Llft Stations
Regulation 22 Application Form
Section 22.7 of Resulation 22:Sewers Not Elioible for Certificati on
e" pioiett ario s*item imormation
Svstein Name Roarinq Fork Water & Sanitation District
.Piiiaer fitta Eastbank Lift Station
Countv':l Garfield
Pate. Fee Paid o1 paylpQnt
attached .. .: I '. .' .Attached
invoice Number and Check
Nrrmhar wus4171029174
SGM.lnc.
Louis Meyer CO License Number 20797
A!_dress 118 West Sixth Street, Suite 200
Glenwood Sprinqs, CO 81601
Email ..LouisM@som-inc.com
(970)945-1004 Fax
Roarino Fork Water & Sanitation District
Tonva Uren. District Administrator
PO Box 1002
Glenwood Sorinos. CO 81601
Emdil info@rfwsd.com
'Phone @70t945-2144 Fax
ii. Prrilect informiition
Location bxlstlno or oronsedsltel Prooosd Ptoteet Camcllv
grlel tocation description
New location, Southwest of Cty.
Rd. 154, Aproximately 114 mile
south of the intersection of Cty.
Rd. 154 and Co. Hwv. 82
Maximum Month Average
Hydraulic Capacig in million
oallons oer div fMGD't
0.102 MGD
Lggal tlesaiption
(e.o., Torvnshio. Rande)Rural Peak Hour Hydraulic Capacity in
million gallons per day (MGD)0.382 MGD
Coiintri rrfield
Latitude 39.4833571 Organic Capacity (lbs. BOD5/day) -
TreaUnent Facilitv Onlv lbs. BODs/dayLonditude07.2945647
Wll a State oifederal grant or loan be sought to
finance any portion of the project (e.9., State
Revolving Fu.1d)?
No x Yes u lf yes, please list
projbct number
Prolect Schedule and Cost Esti
Estimited Birl oodhinti Dale'March 15,2017
Estimaid Completion Date June 30, 2017
estmiteo Proie<t i:mi $180.000
Revised December2013 Section 22.7: Applic,alion Form Erge 1 of7
Colorado Department of Public Health and Environment
Water Quality Control Division
4300 Gherry Creek Drive South, 82
Denver, Colorado 80246-1 530
CD PH E.WQE ngReview@state.co.us
303-692-6298
Regulation 22 - Domestic Wastewater
Step 2: Application Form
Section 22.7: lnterceptor Sewers Not Eligible
for Certification and Lift Stations
Stations
Regulation 22 Application Form
Section 22.7 of Requlation 22:Sewers Not Eligible for Certification and Laft
Prolect and Svstem lnformation
Proiect Title Eastbank Lift Station
Svstem Name Roaring Fork Water & Sanitation District
C.rrrrnlv Garfield
Interceotor/Llft Station Desion lnfomation
a) Name and address of wastewater treatment facility providing treatment (Receiving wastewater facility must fill out
"Receivino Wastewater Entitv Certification" )
Roaring Fork Wastewater Treatment Facility; 3790 CR 109, Carbondale, CO 81623
Site lnformation
2.Vicinity maps of facility location which includes the followlng:
a) 1 mile radius map: habitable buildings, location of public and private potable water wells, an approximate indication of the
tooooraohv. and neiohborino land uses
Provided with report. See Appendix A.
3.Site Location Tanlng
a) Present zoning of the site location?
Rural
b) Zoning within a one (1) mile radius of the site? For New Lift Stations Only.
Provided with report. See Appendix A
4.Floodplain or Natural Hazards
a) ls the facility located in a 1OO-year floodplain or other natural hazard area? lf so, what precautions are being taken?
The lift station structure is not within the 1O0-year floodplain.
b) Has the floodplain been designated by the Colorado Water Conservation Board, Department of Natural Resources or other
aoencv? lf so. olease list aoencv name and the desionation.
N/A
Land Ownership
a) Who owns the land upon which the facility will be constructed? Please attach copies of the document(s) creating authority
for the applicant to construct the proposed facility at this site.
Robert Macgregor; Eastbank, LLC
Llft Sta0on Facilitv Onlv
6.Please describe the period during which service area build-out will occur.
Substantial growth is anticipated, likely approaching buildout in 20 years.
l.Please describe the flows exoected in the first five vears and ten vears of ooeration.
The RE-1 schoolwill be the primary flow contributor in year 1. Within the first 5 years, some additional
contribution is expected from light commercial and affordable housing developments to account for a projected
peak hour flow of 50 gpm. Low-density residential development is expected to begin within 10 years, bringing
to the projected peak hour flow to near 100 gpm.
Revised December2013 Section 22.7: Application Form bge2olT
8.Will the orooosed lift station reolace an existino lift station?
Yes n No x
lf Yes, please describe the current flows and loadlngs that will be switched to the proposed lift station.
N/A
9.Describe emeroencv back-uo svstem in case of lift station and/or oower failure.
An on-site generator will provide backup power.
Proiect lnformaUon
10.a) What entity is financially responsible for the construction of the facility?
RE-1 SchoolDistrict
11.a) What entity has the financially responsibility for owning and long term operating expense of the proposed facility?
Roaring Fork Water and Sanitation District
12.a) What entity has the responsibility for managinq and operatinq the proposed facility after construction?
Environmental Process Control, under contract with Roaring Fork Water and Sanitation District
Additional Factors
13.Please identi! any additional factors that might help the Water Quality Control Division make an informed decision on your
site location aoolication.
Revised December2013 Seclion 22.7: Applialion Form PgF,e3of 7
Water Quality Control Division 4i}00 Cherry Creek Drive South, 82
Denver, Colorado 80246-1 530
C DPH E.WQEnoReview@state,co.us
303-6926298
Engineering Section
Colorado Departnrent
of Public Health t
end Envimumcnt
and Lift Sta$ons
2. Recomrrendataofl of Revlew Agenciee
As required in SEction 2?7(2 aN 3), the applicatioo and the engineering report musl be submittrad to all appropriate local governmenb,
208 planning agencies and State agencies for review and cornment prior to subrnittal to the Division. By signing belotr,, the entity or
agency: 1) ac*norledges receipt of the proposed site location applicatbn, 2) has revioted the proposed site locatton application and
may elect to provide comments, and 3) has provided a recommandatjon to the Division. The recommendation should be based on the
consistency of the proposed site location application with the local comprehensive plan(s) as they relate to water quality and any
adopted water guality management plans(s). Please note: lf a does not recommend approval then the authority
must attached a leller describing the reason for their decision or commenl on next pago.
Applicant Certification and Review Agencies Recommendation
Section 22.7 ol Reoulation 22: lnterceotor Sswers Not Eliqible for Certification
A. Prolect and Swtem lnformadon
Svstem Name Roarino Fork Water & Sanitation Distric{
Proied Title Eastbank Lift Station
Countv Garfield
I certdy that I am familiar with the requirEmenl ot Regulalion 22 - Site Location and
Wastewalar Treatment Works, and have posted the site in accordancs with the Regulations.An engineering report, as described
/rr.4
Th€ systern legal re$esentati!,e is the tegary responsiue agent and dec-Eion-mal0pgduthority (e.9., preskJent of a board, public u,orks
director, owner). The Consultirg Engineer is no't ihe legal representative and gryl sign lhis torm.
6hn t/tt6nrtAl
Garfie,ld 6Dej-
Revised December2013 Section 22.7: Application Form kre4ot7
Signature of Other State or Federal Agencies, lf facility is located on or adjacent to a site that is owned or managed by a
federal or state aqencv.
Role Date Typed Name /Aoencv Siqnature
Recommend Aporoval? I Yes I Ll LVo I L l
Signahrre of Other Basin Water Quality Authority, Watershed Association, Watershed Authority, etc., lf facllity ls located ln
a Water Qualitv Conhol Commisslon Watershed Protection Control Area.
Role Date Tvoed Name / Aoencv Sionature
RecommendAoproval? I Yes I E I ItIo I E
Gomments:
Revised December2013 Section 22.7: Appliealion Form Eage 5 of7
Water Quality Control Division
Engineering Section
€00 Cherry Greek Drive South, 82
Denver, Colorado 80246-i 530
GDPHE.WQEnqReview@state.co.us
303-692-6298Colorado Depaftmenl
of PuhlicHeakh
andF-nvimnment
Lrft
WastewatEr Receivlng Entity Certiflcation
Sec{lon 22.7 ot 222 Sewers Not Eliolble for Certification and Stations
Prdect and Svstcm lnformrfl on
Svsbm Nxne Roarino Fork Waier & Sanitation District
Proiecf Tllle Eaetbank Lift Station
Counlv lGarfieu
Wastqrreisr - Certiflca6on of Avallable Treatnent
Receiylna waatesaier treaffiont entitv lnfotmatlon
Receivino urastelvater sgffncnl entitv and facilitv Roarino Fork Wasteurater Facilitv
County Garlieft
CDPS discharge permit number and expiration date CO-0044750 | coosdischarsepermitcapacity I Ll'J
Site location approml number and date (please
attacfi a coov of aDoroval l€tterl SA 3464 | site tocation appro\Ed capacity I Ii['J
Proooged iicilitv caoactW imoacts on recelvlno wr3tetrtnter treatmcnt facilitv lorolected at bulldqrt or z0{,saru)
Proposed project hydrgulic capacitf maximum month average 0.102 million gallons per day
Proposed proJett hydraulic Sacr'tf pcak hour 0.382 million gallons perday
ProDosed oroiect oroanic caoacitv: maximum monh awraoe 170 bs BODr/dav
Proposed proiect will increase the r€ceMng treafnont tacility's
hvdraulic badino caDacitv b (% of total caoecitv):57.6To'as peroent of Master Planned Cepacity (0.321 MGD)7o
Prcposed prpftxt ni[ increase lhE reoeMrq treatneni facility's
oroanic loadno capacitv to (% of total caoacitv);42.8%'as percnetof Master Planned Capacity (0.321 MGD)%
Trc.lment Certtftcaton (22.7 (f l(O {l}l
I cefffu ftat the recaivins wasEwatsr beatment facilitv will treat the wasbwater from th€ prooosod wastewder facilitv oniect
Yee, will provide treafnent I EI I No. will not orovide featment I LI
Caoacltv Gertlf,eatlon (22.7 lrll0 lllll
I certify tfrat t€ rBceMr€ rvasbwater treatnent facility h not presently recaiving wastes (hydraulic and organic /
loads) in excess olthe abole lisbd sit6 location approral and discharge permit to treat the proFded dischapl
from the new inbrceDrtor seuer or from the neu/ or ercanded lift sbtion. as listed abow (ini6al in box). I '/a4
OR \ ,-./
I c€rlify thatlhe BceMng wBste$ratertreatTent facility ctoes not €un€ntly haw the capaoty to serue the
propoaed proje<i flona bui ig urder construstion, orwill be in a phased construction of nevv or expanded hcilitieo
and will have the necessary capaclty to treat Ste proiectad discharge from the new interceptor sevrer or fiorn tha
netArorexDonded lift stetion. as lbted abvs (initial in box).
Note:Prqec$onS sf flotv tnd loading to th€ trcatmeot ,aci{ty wer th€ period during which bulld out of the scfllce area niil occur or nrenty y6are,
wruch€t,er ls les$, as rtt{, a3 qrrrent and future danl capacity information must be provided to d€monshate the plan lor maintainlng
adequate treatnert capacity. Any proposed treatnent planl phaoed construcffon must be shou,n h lhe Water Quality Mansgement Plan
{reftrence. silach). or br, roormrirte Dlennlm and enoirieerino sltdieB (refereftE- attarfi)
Gomollancc Statu. CordficddcnIZLT (tXO 0ll))
I carfify that ttle lBceMr€ wa$swat€r treaunenl facility has not be€n in violation of any effluent limitations in its
rlirnhrrn aefmii frrr tha lret lu6 marc linilial in tnvl -lafrJ.
I certify that fle recoMrlg wastewater treatnent facility ls not operating und6r a Notioa of Molation and/or Gease /
and Deeist fuer from the Divbion resultino hom disrfiame oermit violations linitial in borl t #t
Note:I t]r€l€ narre D€,gn €muent violalions or if the rBoefving wasto\,vater treatm€nt facllity B operating under a Notice ot ViolauoillndJsr€GlEe arld
DB3F| Or(hr forn tlp Dhtbbn, please provide addiuonal deocripfion of the situation and the trsarnent er{ityr propoeed corecltur
measulgs lo acfiisvg consistent co'ndiance. The Divlsion will evaluate information provk ed and determine if approd sfro(rld be granled,
oranied wilh conditions- ordenhd-
Revised December 201 3 Section 22.7: Application Form Ecge 6 ol7
nted above is accurate and
Revised December2Ol3 Section 22.7'. Applicalion Form Pr€,e7 ol7