Loading...
HomeMy WebLinkAbout1.0 ApplicationGARFIELD COUNTY Building & Planning Department 108 8th Street, Suite 201 Glenwood Springs, Colorado 81601 Telephone: 970.945.8212 Facsimile: 970.384.3470 www.garfield-countv.com Subdivision Application Form GENERAL INFORMATION (To be completed by the applicant.) Overview • Subdivision Name: y Type of Subdivision (check one of the following types): Sketch Plan X Preliminary Plan Final Plat Name of Property Owner (Applicant):_kLayy„ Q ➢ Address: 132 Park Ave. Y City: Basalt State: co c6t0 927-9119 Telephone: Zip Code: 81601 FAX: 9 2 7- 4 0 2 7 v Name of Owner's Repres4ntative, if any (Attorney, Planner, etc): Steve Oger, Rick Oger, Gary Setnes srac 37.1-001 c/o Rudd Construction132 ParkAve. 927-9119 • Adc� ss: Telephone: • City: Basalt State: co Zip Code: 81601 FAX: 927-4027 i' Name of Engineer: Sopris Engineer ing,LLC v Address: 502 Main - A3 Telephone: 704-0311 City: Carbondale, State: co Name of Surveyor: Sexton Survey Address: 128 W. 3rd. ➢ City: Rifle Zip Code: 8 1 6 2 3 FAX: 7 0 4- 0 3 13 Telephone: _62 s _11.11 State: C 0 Zip Code: 8 1 6 5 0 FAX: 6 2 5- 3 1 6 0 ➢ Name of Planner: ➢ Address: Telephone: ➢ City: State: Zip Code: JUI vJi004 BUILUiiv(, 0, GENERAL INFORMATION continued... ➢ Location of Property: Section 35 Township 6S Range 88W ➢ Practical Location / Address of Property: 8 5 7 5 CR 115 Glenwood Springs, CO 81601 ➢ Current Size of Property to be Subdivided (in acres): 48.520 ➢ Number of Tracts / Lots Created within the Proposed Subdivision: 4 ➢ Property Current Land Use Designation: 1. Property's Current Zone District: 2. Comprehensive Plan Map Designation: Proposed Utility Service: ➢ Proposed Water Source: Well, Permit x/2570297 ➢ Proposed Method of Sewage Disposal: ISDS ➢ Proposed Public Access VIA: CR 1 1 5, DrJ Le _Fermi t 3� ➢ Easements: Utility: Kinder Moraan_, Holy Cross, Qwest Ditch: Thad Neislanik Ditch ➢ Total Development Area (fill in the appropriate boxes below): {1) Residential Units I Lots Size (Acres) Parlung 'Provided Single Family 3 11.352 12+ Duplex Multi -Family, Mobile Home Total 3 11.352 12+ Floor Area (sci. Size (Acres) Parkinq`Provided (2) Commercial (3) Industrial (4) Public 1 Quasi -Public (5) Open Space f>Common Area 37.168 Total 37.168 ➢ Base Fee: Sketch Plan - $325.00; Prelim Plan - $675.00; Final Plat - $200 paid on ➢ Plat Review Fee (see attached fee schedule) 2 • • I. THE SUBDIVISION PROCESS In order to subdivide land in Garfield County, an Applicant is required to complete the following land use processes in the following order: 1) Sketch Plan Review Process, 2) Preliminary Plan Review Process, and 3) Final Plat Review Process. This section will briefly describe the nature of each process and provide general direction including subdivision regulation citations to a potential applicant requesting subdivision approval in Garfield County. All of the Garfield County Zoning and Subdivision Regulations are located for purchase at the Planning Department and can also be found on the World Wide Web at the following address: http://www.garfield-county.com/building and planning/index.htm A) The Sketch Plan Review (Section 3:00 of the Subdivision Regulations) 1. Purpose The purpose of the Sketch Plan process is to allow an individual an opportunity to propose a subdivision in a "sketch" format to the Planning Department and the Garfield County Planning Commission in order to obtain a cursory review for compliance with the County's land use review documents, regulations, and policies to identify any issues that would need to be addressed if the proposed subdivision were to be pursued. 2. Applicability Any individual proposing a subdivision in Garfield County is required to complete the Sketch Plan review process as the first step in Garfield County's Subdivision process. More specifically, Garfield County defines a subdivision (Section 2:20.48) as the division of a lot, tract or parcel of land into two (2) or more lots, tracts, parcels or separate interests, or the use of any parcel of land for condominiums, apartments or other multiple -dwelling units, as further defined by Colorado state law. 3. Application / Submittal Requirements In order to apply for a Sketch Plan Review an Applicant is responsible for reviewing Section 3:00 of the Subdivision Regulations and providing enough information to the Planning Department in the application to conduct a thorough review and provide the resulting comments to the Planning Commission for their review and comments. Specifically, Section 3:30, 3:32, and 3:40 of the Subdivision Regulations contain the specific information required to be submitted to the Planning Department in order to satisfy the application requirements in addition to the information requested on this application form. 4. Process / Public Meeting The Sketch Plan review process is considered a 1 -step process because the application is reviewed only by the Planning Commission at a public meeting. In order to appear before the Planning Commission, an applicant will have submitted all required application submittal requirements mentioned above to the Planning Department Staff. Once submitted, Staff will have 15 working days to review the application to determine if all the required submittal information has been submitted as required. If Staff determines that all the required information has been submitted, a letter will be sent to the applicant indicating the application has been deemed "technically complete." It is at this point Staff will also indicate when the application has been 3 • • scheduled to be reviewed before the Planning Commission and will request the applicant supply additional copies to provide the Commission for their review. If Staff determines that all the required information has not been submitted, a letter will be sent to the applicant indicating the application does not comply with the submittal requirements and therefore has determined the application to be "technically incomplete." The letter will also outline the applications deficiencies so that the applicant knows what additional information needs to be submitted. At this point, the applicant has 6 months (180 days) to provide the necessary information to the Planning Department to remedy the application so that it may be deemed technically complete. If the application has not been deemed technically complete within this time, the application will be terminated. Once the application has been deemed technically complete and a date has been established as to when the Planning Commission will review the application, Staff will conduct a land use review of the application using the County's land use regulatory documents including the Zoning Resolution, Subdivision Regulations, and the Comprehensive Plan of 2000. In addition, Staff will also consider referral comments provided from a variety of state and local agencies who may also review the application. As a result, Staff will write a Memorandum on the proposed subdivision to the Planning Commission containing the results on the land use analysis. This Memorandum will also be furnished in advance to the applicant. At the date and time set for the public meeting before the Planning Commission, Staff will present the findings in the Memorandum and the applicant will be required to present the proposed subdivision and respond to comments and questions provided by the Planning Commission. The comments provided to the Applicant by the Planning Department and the Planning Commission as a result of the Sketch Plan Process will be kept on file in the Planning Department for 1 -year from the meeting date before the Planning Commission. If an Applicant does not submit a Preliminary Plan application to the Planning Department within the 1 -year timeframe, the Sketch Plan file will be closed and the Applicant will need to reapply for a Sketch Plan review prior to a Preliminary Plan review. B) Preliminary Plan Review (Section 4:00 of the Subdivision Regulations) 1. Purpose The purpose of the Preliminary Plan review process is to conduct a thorough review of the many aspects that are associated with dividing land in Garfield County for the purposes of residential, commercial, and industrial development. This is the most intensive review step where the Building and Planning Staff, the Planning Commission, and the Board of County Commissioners (BOCC) will conduct a thorough review of all the issues associated with the proposed subdivision against the County's regulatory requirements. Ultimately, the purpose of this process is to identify all the major issues in the proposed subdivision by using the County's Zoning Resolution, Subdivision Regulations, Comprehensive Plan of 2000, as well as other state and local referral agencies that will provide comments on any issues raised in their review. This is the process that will either approve or deny the application request. 4 • • 2. Applicability Any individual proposing a subdivision in Garfield County is required to complete the Preliminary Plan review process as the second and most intensive step in Garfield County's Subdivision process. More specifically, Garfield County defines a subdivision as the division of a lot, tract or parcel of land into two (2) or more Tots, tracts, parcels or separate interests, or the use of any parcel of land for condominiums, apartments or other multiple -dwelling units, as further defined by Colorado state law. 3. Application / Submittal Requirements In order to apply for a Preliminary Plan Review, an Applicant must have already completed the Sketch Plan review process addressed in Section 3:00 of the Subdivision Regulations. An applicant requesting Preliminary Plan review will be required to submit this application form, all the required submittal information contained in Sections 4:40 to 4:94 of the Subdivision Regulations as well as address all of the applicable Design and Improvement Standards in Section 9:00 of the Subdivision Regulations. In addition to the substantive submittal information related to the proposed subdivision project itself, an applicant is required to complete all the public notice requirements so that legal public hearings can be held before the Planning Commission and the BOCC which is addressed in Sections 4:20 — 4:31 of the Subdivision Regulations. 4. Process / Public Hearings The Preliminary Plan review process is considered a 2 -step process because the application is ultimately reviewed by two County decision-making entities during public hearings: the Planning Commission who makes a recommendation to the BOCC. In order to obtain dates for the public hearings before the Planning Commission and the BOCC, an applicant will have submitted all required application submittal requirements mentioned above to the Planning Department Staff. Once submitted, Staff will have 30 working days to review the application to determine if all the required submittal information has been submitted as required. If Staff determines that all the required information has been submitted, a letter will be sent to the applicant indicating the application has been deemed "technically complete." It is at this point Staff will also indicate when the application has been scheduled to be reviewed before the Planning Commission / BOCC. Additionally, Staff will provide the applicant with the notice forms to be mailed, published, and posted. If Staff determines that all the required information has not been submitted, a letter will be sent to the applicant indicating the application does not comply with the submittal requirements and therefore has determined the application to be "technically incomplete." The letter will also outline the applications deficiencies so that the 5 • • applicant knows what additional information needs to be submitted. At this point, the applicant has 6 months (180 days) to provide the necessary information to the Planning Department to remedy the application so that it may be deemed technically complete. If the application has not been deemed technically complete within this time, the application will be terminated. Once the application has been deemed technically complete and a date has been established as to when the Planning Commission / BOCC will review the application, Staff will conduct a land use review of the application using the County's land use regulatory documents including the Zoning Resolution, Subdivision Regulations, and the Comprehensive Plan of 2000. In addition, Staff will also consider referral comments provided from a variety of state and local agencies who may also review the application. As a result, Staff will write a Memorandum on the proposed subdivision to the Planning Commission / BOCC containing the results on the land use analysis. This Memorandum will also be furnished in advance to the applicant prior to the public hearings. As mentioned above, Staff makes a recommendation to the Planning Commission and the BOCC regarding the issues raised in the analysis of the proposed subdivision. The Applicant will first propose the subdivision to the Planning Commission who is responsible for making a recommendation of approval, approval with conditions, or denial to the BOCC. Next, the application will be reviewed by the BOCC during a regular public hearing. The BOCC will consider the recommendations from the Planning Staff and the Planning Commission, the information presented by the applicant, and the public. As a result, the BOCC is the final decision-making entity regarding the proposed subdivision and will either approve, approve with conditions, or deny the application. If the BOCC approves the subdivision application at the public hearing, the approval shall be valid for a period not to exceed one (1) year from the date of Board approval, or conditional approval, unless an extension of not more than one (1) year is granted by the Board prior to the expiration of the period of approval. (See the specific information provided in Section 4:34 of the Subdivision Regulations.) Following the hearing, Staff will provide a resolution signed by the BOCC which memorializes the action taken by the Board with any / all conditions which will be recorded in the Clerk and Recorder's Office. Once an applicant has Preliminary Plan approval, they are required to complete the third and final step in the County's Subdivision Process: Final Plat Review. C) Final Plat Review (Section 5:00 of the Subdivision Regulations) 1. Purpose The purpose of the Final Plat review process is to provide the applicant with a mechanism to prove to the County that all the conditions of approval required during the Preliminary Plan review process have been met / addressed to the satisfaction of the Planning Staff and the BOCC. This being the case, the chairman of the BOCC will 6 • • sign the Final Plat and have it recorded memorializing the subdivision approval granted by the BOCC. This is the last step in the County's subdivision process. 2. Applicability Any individual proposing a subdivision in Garfield County is required to complete the Final Plat review process as the third and last step in Garfield County's Subdivision process. More specifically, Garfield County defines a subdivision as the division of a lot, tract or parcel of land into two (2) or more lots, tracts, parcels or separate interests, or the use of any parcel of land for condominiums, apartments or other multiple -dwelling units, as further defined by Colorado state law. 3. Application / Submittal Requirements In order to apply for a Final Plat review, an Applicant must have already completed the Preliminary Plan review process addressed in Section 4:00 of the Subdivision Regulations. An applicant requesting Final Plat review will be required to submit this application form, all the required submittal information contained in Section 5:00 of the Subdivision Regulations and responses to all the conditions of approval required as part of the Preliminary Plan review process. 4. Process The Final Plat review process is considered a 1 -step process because the application is ultimately reviewed by the Building and Planning Staff and presented to the BOCC for their signature if the application satisfies all the required submittal information to the satisfaction of the Building and Planning Department. If Staff determines that all the required information has been submitted, a letter will be sent to the applicant indicating the application has been deemed "technically complete." It is at this point Staff will also indicate when the application has been scheduled to be presented to the BOCC for signature. (This is not a public hearing or meeting and therefore does not require public notice.) If Staff determines that all the required information has not been submitted, a letter will be sent to the applicant indicating the application does not comply with the submittal requirements and therefore has determined the application to be "technically incomplete." The letter will also outline the applications deficiencies so that the applicant knows what additional information needs to be submitted. Once the application has been deemed technically complete and a date has been established as to when the BOCC will review the Final Plat, Staff will review the application / Final Plat in terms of adequacy to determine if all the submittal information satisfies the Final plat requirements as well as the responses to the conditions of approval. During this review, Staff will forward the Final Plat the County Surveyor for review and a signature. In the event there are additional questions or clarification issues to be addressed, the County Surveyor will generally contact the applicant to have the plat adjusted as necessary. Once, Staff has completed the review and all required information has been submitted to the satisfaction of the Planning Department 7 • • and the County Surveyor has signed the Final Plat in Mylar form, it will be scheduled at the next BOCC meeting to be placed on the consent agenda with a request to authorize the Chairman of the BOCC to sign the plat. Once the Final Plat is signed, it is then recorded by the County Clerk in the Clerk and Recorder's Office for a fee of $11 for the first sheet and $10 for each additional sheet thereafter. This fee shall be paid by the applicant. This act of recording the signed Final Plat represents the completion of the Garfield County Subdivision Process. Please refer to the specific language in the Final Plat portion (Section 5:00) of the Subdivision Regulations for specific timelines and additional responsibilities required of the applicant to complete the Final Plat process. Please Note: This information presented above is to be used as a general guide for an applicant considering a subdivision in Garfield County. It is highly recommended that an applicant either purchase the Garfield County Zoning Resolution and Subdivision Regulations or access them on-line at: http://www.qarfield-county.com/buildinq and planninq/index.htm in order to ascertain all the necessary requirements for each of the three steps including Sketch Plan Review, Preliminary Plan Review, and Final Plat Review. I have read the statements above and have provided the required attached information which is correct and accur,ate to the best of my knowledge. / (Sig a re of applicant/owner) Last Revised: 11/21/2002 8 if 0/ o y Date WAYNE RUDD 132 Park Ave. Basalt, CO 81621 970-927-9119 Fax 927-4027 May 7, 2004 Mark Bean Garfield County Planning Department 108 8th St. Glenwood Springs, CO 81601 RE: Overview Subdivision Dear Mark: • Please be advised that I, as property owner, authorize Steve Oger, Rick Oger, and Gary Setnes to act as my representatives and co -applicants, regarding the subdivision application and related approval activities of Overview Subdivision. Thank you for your assistance. Sincerely, WayRudd Owner, 29 Peaks, Parcel B • • Overview Subdivision, Garfield County, CO The parcel to be subdivided is owned by Wayne Rudd. The three co -applicants Steve Oger, Rick Oger au .' Gary Setness are long time employees of Rudd Construction. Upon Final f it approval Wayne Rudd has agreed to sell the three lots at a greatly reduced price, so that these employees will have the ability to build their own homes. All three of the employees are renters, and have never owned homes in the Roaring Fork Valley. In all likelihood, this opportunity would be their only possibility of owning their own homes. It is anticipated that only one single family home and barn/accessory structure would be buil, on each lot. This Subdivision will be served by the following utilities: Kinder Morgan Gas - Holy Cross Electric - Qwest Telephone - All of these utilities are currently available on the proposed Lot 3. It is not known if cable T1 is available at this time. Utility easements to each lot will be provided on the fmal plat. The proposed lots will be served by one common drive, and a drive easement will be provided on the final plat. A driveway permit off of County Road 115 is in place. The proposed lots will be served by the existing well, and a well sharing agreement will be in place at the time of final plat. Sewage disposal will be accomplished with Individual Septic Disposal Systems. There are no known radiation hazards on the site. There are no rivers or streams on the site, thus the proposed development will have no impact on public waters. Development will occur primarily on the Southernmost part of the parcel, which is less steep than the topography to the North. Care will be taken to prevent erosion of any excavated areas. It is proposed that the 3 lot owners will have an undivided 1/3 interest in the common/agricultural lot. (Joins sheet 14) R. 88 W i R. 87 • • Non -Technical Descriptions Soil Survey Area: 655 ASPEN -GYPSUM AREA, COLORADO, PARTS OF 'T • !TT T !l • TI TT TTT T • %TT1 nTTTrTIT /l!ST TITTTT[T Map unit: 95 Showalter-Morval complex, 15 to 25 percent slopes Description Category: SOI This map unit is on alluvial fans, high terraces, and valley sides. This unit is 45 percent Showalter very stony loam and 35 percent Morval loam. The Showalter soil is deep and well -drained. It formed in alluvium derived dominantly from basalt. The surface is covered with 10 to 15 percent stones, 5 percent cobble, and 5 percent gravel. The surface layer is very stony loam 8 inches thick. The upp er 3 inches of the subsoil is very cobbly clay loam. The lower 28 inches of the subsoil is very cobbly clay. The substratum to a depth of 60 inches or more is very cobbly clay loam. Permeability is slow. Available water capacity is moderate. Effective rooting depth is 60 inches or more. Runoff is rapid, and the hazard of water erosion is high to very high. The Morval soil is deep and well -drained. It formed in alluvium derived dominantly from basalt. The surface layer is loam 7 inches thick. The upper 12 inches of the subsoil is clay loam. The lower 4 inches is loam. The substratum to a depth of 60 inch es or more is loam. Permeability is moderate. Available water capacity is moderate. Effective rooting depth is 60 inches or more. Runoff is rapid, and the hazard of water erosion is very high. Monday, July 19, 2004 Page 1 of 1 • • ?,;A111P�3i^J7141ii1d1511ICy3",idif{NV!3+�F:?i3l;F1ill�FdfflfilliG'dliili(SER!lUlIIlkitl;isE:7li�t.itt3fiplRUilHlitlJlfiS;lfBMRflllt;till;i7_'';1i61AIIGiGi;��dlFlG!:I!4g111ifd1lG:;i;i1�!?tiftll:lglif+1111tlldlf'illlli;AH�181d7&dfigi8fh2i51�((��E1t4AEf✓1�!!f@lilil3iiS1ti1E6�Ef Non- Technical Descriptions ^.fi:l':Ifilli'isIlfitliliiliLyltfi6'r2r�3:Wt:Sn,:l'l;:(i.11[iIiI11111S1ki.;711tCTY!itiifttillrt�ni_a_.^,t61:llifli111ttidlBtlu,i,F.':11))�!IfltiVliui::�+tt;:111t:iI.Ulilltlltl,•::' :'"i!i(11!llft:lnlutBUI:C"il lltllitlilRtlllll',1:1i)S�iltO.`!!?1f176lfbiilln:evt.Zt3:L�:n1;111G1161i31t1{7p(1C91WWtIIWif7tD Soil Survey Area: 655 ASPEN -GYPSUM AREA, COLO D O, PARTS OF L�"1 ! a"'iT •- !•i G • t77; -:1T T' 1 AY'i[\ b'\TTTTTAT !-1 !lY YAYrnTT"1P Map unit: 64 Jerry loam, 25 to 65 percent slopes Description Category: SOI This deep, wet -drained soil is on mountainsides. This soil formed in alluvium derived from sandstone, shale, and basalt. The surface layer is stony loam about 3 Inohes thick. The subsoil is cobbly clay loam about 37 inches thick. The substratum is cob bly clay to a depth of 60 Inches. Permeability is slow, and available water capacity Is moderate. Effective rooting depth is 60 inches or more, Surface runoff is rapid, and the erosion hazard Is vary high. Map unit: 94 Showalter-Morval complex, 5 to 15 percent slopes Description Category: SOI This map unit 1s on alluvial fans, high terraces, and valley sides. This unit is 45 percent Showalter very stony loam and 35 percent Morval loam. The Showalter soil is deep and well-dralned. It formed in alluvium derived dominantly from basalt, The surface is covered with 10 t0 15 percent stones. The surface layer is very stony loam 8 inches thick. The upper 3 Inches of the subsoil is very cobbl y clay loam. The lower 28 inches Is very cobbly clay. The substratum to a depth of 80 inches or mors Is very cobbiy clay loam. Permeability is slow. Available water capacity is moderate. Effective rooting depth Is 60 inches or more. Runoff Is rapid, and the hazard of water erosion is moderate to high. The Morval Soil is deep and well -drained. It formed in alluvium derived dominantly from basalt. The surface layer is loam 7 inches thick. The upper 12 inches of the subsoil is clay loam. The lower 4 Inches are loam, The substratum to a depth of 60 Inc hes or more Is loam. Permeability is moderate. Available water capacity is moderate. Effective rooting depth Is 60 Inches or more. Runoff is medium to rapid, and the hazard of water erosion is high to very high. ti,ifBIHP)iZLIR a!!titE.'SdfadaDial IMIEttR'I1HH!al) 13E1F,11IO2KJI! ii6Eiil7I!iMilffif51711l11c1t911161111i1 tllPill1i:it.,llit; I:1'L'.I"%t11iIMYl:f italllKWtIupturn' tau tuiplAWifttium! tmzit:iunWSifg 11:,;;;;I farm Itioj MittidlCliIM114W Tuesday, July 20, 2004 Page 1 of 1 v P.O. Box 1908 1005 Cooper Ave. Glenwood Springs, CO 81602 • • Z4NC4NELL4 4110 4SSOCI4TES, INC. ENGINEERING CONSULT1NTS June 24, 2004 Mr. Mark Bean Garfield County Planning Department 108 Eighth Street, Suite 201 Glenwood Springs, CO 81601 RE: Overview Subdivision Dear Mark: (970) 945-5700 (970) 945-1253 Fax This report presents the findings of the water supply investigations performed by Zancanella and Associates, Inc. for the proposed Overview Subdivision. Information contained in this report covers estimated future domestic water uses, legal water supply, well pump test, and water quality analyses. Water Requirements The new subdivision will consist of 3 lots with one dwelling unit each. We have assumed that each EQR will represent 3.5 people using 100 gallons of water per person per day. Water will be diverted to irrigate up to 10,000 square feet of lawn or other equivalent outside uses for each residence. Legal Supply As can be seen from Table 1, the subdivision will divert an average 2.66 AF annually, and consumptively use 1.37 AF The peak month of June would require a continuous averag, diversion of 3.63 gpm. The subdivision is to be supplied by a shared exempt domestic we!' which has been drilled and tested. The Overview Weil was drilled under permit number 2'x)0297 (copy attached). This is an exempt domestic pc- mit, intended to serve a maximum of three residences and to be the only well on the 43.82 acre tract. Physical Supply The Overview Well was completed on May 21, 2003 by Shelton Drilling Corporation at a total depth of 160 feet. The well is located in the NE 1/4 of the SE 1/4 of Section 35, Township 6 South, Range 88 West of the 6th P.M. The location of the well can be plotted 1511 feet from the south section line and 325 feet from the east section line. The approximate location of the well and Lhe Overview Subdivision boundary are shown on the attached general location map. Figure 1. The well was drilled through a 20 foot section of Tertiary basalt before entering the Pennsylvanian Maroon from 20 feet to the total depth of • • the well. A copy of the well construction report and a graphical representation of the well (Figure 2) are attached. A 4 hour pump test of the Overview Well was conducted on June 1, 2004 by J & M Pump Company utilizing the electric submersible pump. The pump test was performed at a rate of 15 gallons per minute (gpm). The rate was maintained at 15 gpm throughout the 4 hour test period. The drawdown and time data collected during the test are presented in Table 2. We have plotted the results of the test in a water level vs. time curve as shown on the attached Figure 3. The maximum drawdown during the 4 hour test was 0.17 feet. The water level stabilized early in the test and did not vary through the remainder of the test. Because of the relatively small amount of drawdown, no recovery data were collected. The test indicates that the well will probably be able to operate for extended periods at a rate of approximately 15 gpm. This amount, with water storage to handle peak demands, should be adequate to serve the 3 lots. It is our understanding that 10,000 gallons of shared fire and peak demand storage will be installed. Water Quality Water samples were collected during the pump test and sent to ACZ Laboratories in Steamboat Springs for independent analyses. The lab tests included analyses for various inorganic chemicals, nitrate/nitrite, total dissolved solids (TDS) and some of the physical properties of the water. A total coliform bacteria sample was collected and sent to the state lab in Grand Junction for analysis. The coliform bacteria test indicates that coliform bacteria were absent from the sample. The result from the bacteria test is attached. Results of the analyses from ACZ Labs are pending. They will be forwarded to your office as soon as they are received. If you have any questions, please call our office at (970) 945-5700. Very truly yours, Zancanella and Associates, Inc. ( .(-2,4u.Fcv�iV` Thomas A. Zancanella, P.E. Bradley C. Pe= , Geologist Attachments cc: Wayne Rudd Z:\97000's\97404 Rudd, Wayne\97404.08 Overview Subdivision\Bean-WaterSupply.doc 2 Table 1 Overview Subdivision - Estimated Water Requirements Domestic Demands Domestic Demands Other Demands No. of EQR's Residential 3.0 units No. of EQRs for ADU s 0.0 units Pond Surface Area 0 acres No. persons/residence 3.5 cap/unit No. persons/unit 3.5 cap/unit Annual Net Evaporation 2.74 ft No. gallons/person/day 100 gpcd No. gallons/person/day 100 gpcd Percent Consumed 15% Percent Consumed 15% Lawn Irrigation 10000 sq-ft/unit Lawn Irrigation 1500 sq-ft/unit Irrigated Open Space 0 acres Application Efficiency 80% Application Efficiency 80% Application Efficiency 80% Crop Irrig reqmnt (CIR) 1.73 ft Crop Irrig reqmnt (CIR) 1.73 ft Crop Irrig reqmnt (CIR) 1.73 ft Water Use Calculations Diversion Requirements Consumptive Use (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) Domestic ADUs Dom\Comm Open Space Pond Average Domestic ADUs Dom\Comm Open Space Pond Average Month In-house In-house Irrigation Irrigation Evap. Total Flow for Dom In-house In-house Irrigation Irrigation Evap. Total Consumption (ac -ft) (ac -ft) (ac -ft) (ac -ft) (ac -ft) (ac -ft) (gpm) (ac -ft) (ac -ft) (ac -ft) (ac -ft) (ac -ft) (ac -ft) (gpm) January 0.10 0.00 0.00 0.00 0.00 0.10 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 February 0.09 0.00 0.00 0.00 0.00 0.09 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 March 0.10 0.00 0.00 0.00 0.00 0.10 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 April 0.10 0.00 0.00 0.00 0.00 0.10 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 May 0.10 0.00 0.29 0.00 0.00 0.39 2.86 0.01 0.00 0.23 0.00 0.00 0.25 1.81 June 0.10 0.00 0.39 0.00 0.00 0.48 3.63 0.01 0.00 0.31 0.00 0.00 0.32 2.43 July 0.10 0.00 0.36 0.00 0.00 0.46 3.33 0.01 0.00 0.29 0.00 0.00 0.30 2.19 August 0.10 0.00 0.22 0.00 0.00 0.32 2.36 0.01 0.00 0.18 0.00 0.00 0.19 1.41 September 0.10 0.00 0.19 0.00 0.00 0.29 2.17 0.01 0.00 0.15 0.00 0.00 0.17 1.27 October 0.10 0.00 0.04 0.00 0.00 0.14 1.01 0.01 0.00 0.03 0.00 0.00 0.05 0.34 November 0.10 0.00 0.00 0.00 0.00 0.10 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 December 0.10 0.00 0.00 0.00 0.00 0.10 0.73 0.01 0.00 0.00 0.00 0.00 0.01 0.11 Annual 1.18 0.00 1.49 0.00 0.00 2.66 0.18 0.00 1.19 0.00 0.00 1.37 24 -Jun -04 Zancanella & Assoc., Inc. Water Resources Engineers Glenwood Springs, CO Job# 97404.08\eqruse.xls 1' .. � �4'. �•ET R88W •..770 7,75 7z - ?426 • G ao _ �f`.p-.> � � . `�-�..,�,-.,�.. ,...-•,r'.-'°-^"",,.tea 747i „y✓• Spi?teg . •1 1 42a • 4C a (Rana!! 1 0 00 Scale in Feet T6S T7S PROJECT LOCATION MAP SCALE: = 2000' DATE: MAY 10, 2004 SHEET: 1 OF 1 DRAWN BY: BCP CHKD BY: BCP APPD BY: TAZ DRAWING: LocTopo.dwg OVERVIEW SUBDIVISION ZANCANELLA AND ASSOC/A ?Z ENG/NEER/NC CONSUL TANTS POST OFFICE BOX 1906 - 1005 COOPER AVENUE GLENWOOO SPRI N0S, COLORADO 81602 (970) 945-5700 FIGURE NO. 1 PR0JECT-17404.08 GROUND LEVEL Tertiary Basalt Pennsylvanian Maroon formation TOTAL DEPTH 160' 0 20- 40- 60- 80- 100- 120- 140- 160- i CEMENT 10'-40' 0' T ❑ 40' 9' HOLE DIAMETER -1' TO 40' 0,240 WALL 7" PLAIN STEEL CSG 40' TO 160' 6.5' HOLE DIAMETER 36' TO 120' 0.250 WALL 5,5' PVC CSG STATIC WATER LEVEL 107.0' ON JUNE 1, 2004 120' TO 160' 0,250 WALL 5.5" PVC PERF CSG OVEKVIEW WELL WELL DETAIL SCALE NOT TO SCALE DATE JUNE 22, 2004 SHEET 1 OF 1 DRAWN BY: BCP CHKD BY: BCP APPD BY: TAZ PLAN NO. WellDetail.dwg OVERVIEW SUBDIVISION ZANCANELLA ANL' ASSOCIATES, INC ENGINEERING CONSUL TANTS POST CFFICE BOX 1900 - 1005 COOPER AVENUE GLENw000 SPRINGS, COLORADO 01802 (970) 945-5700 FIGURE NO. PROJECT: 1 74,04 08 • • Well ID: TABLE 2 Pump Test Data Overview Subdivision Well Job No.: 17404.08 Client: Wayne Rudd Test By: J & M Pump Analysis By: BCP M.P. = Top of Casing Q = 15 gpm r= ft 107.0 ft b= ft Time/Date on: 6/1/04 8:30 AM Time/Date off: 6/1/04 12:30 PM Test Length: 4:00:00 total time TIME Time (minutes) W.L. Measurement Drawdown (feet) Q (gpm) t' (minutes) tit' (feet) (inches) 6/1/04 8:30 AM 0 107 0.0 SWL 0 6/1/04 8:31 AM 1 107 2.0 0.17 15 6/1/04 8:32 AM 2 107 2.0 0.17 15 6/1/04 8:33 AM 3 107 2.0 0.17 15 6/1/04 8:34 AM 4 107 2.0 0.17 15 6/1/04 8:35 AM 5 107 2.0 0.17 15 6/1/04 8:36 AM 6 107 2.0 0.17 15 6/1/04 8:37 AM 7 107 2.0 0.17 15 6/1/04 8:38 AM 8 107 2.0 0.17 15 6/1/04 8:39 AM 9 107 2.0 0.17 15 6/1/04 8:40 AM 10 107 2.0 0.17 15 6/1/04 8:42 AM 12 107 2.0 0.17 15 6/1/04 8:44 AM 14 107 2.0 0.17 15 6/1/04 8:46 AM 16 107 2.0 0.17 15 6/1/04 8:50 AM 20 107 2.0 0.17 15 6/1/04 8:55 AM 25 107 2.0 0.17 15 6/1/04 9:00 AM 30 107 2.0 0.17 15 6/1/04 9:10 AM 40 107 2.0 0.17 15 6/1/04 9:20 AM 50 107 2.0 0.17 15 6/1/04 9:30 AM 60 107 2.0 0.17 15 6/1/04 9:45 AM 75 107 2.0 0.17 15 6/1/04 10:00 AM 90 107 2.0 0.17 15 6/1/04 10:15 AM 105 107 2.0 0.17 15 6/1/04 10:30 AM 120 107 2.0 0.17 15 6/1/04 11:00 AM 150 107 2.0 0.17 15 6/1/04 11:30 AM 180 107 2.0 0.17 15 6/1/04 12:00 PM 210 107 2.0 0.17 15 6/1/04 12:30 PM 240 107 2.0 0.17 15 6/23/2004 Zancanella & Associates, Inc. Well Pump Test.xls 0 10 20 30 40 50 60 m 70 J 80 L. 1.1 90 10( 1 10 Figure 3 Pumping Test - 6/1/04 Overview Subdivision Well 100 Time (min) 1,oco 10,000 100,000 Q = 15 gpm throughout test. 110 120 130 140 150 160 Pump Set at 155 ft. Total Depth = 160 ft. 6/3/2004 Zancanella & Associates, Inc. Static Water Level = 107.0 ft. Well Pump Test.xls Ill Form No. OFFICE OF E ,.,TATE ENGINEER • GWS-25 COLORADO DIVISION OF WATER RESOURCES 818 Centennial Bldg., 1313 Sherman St., Deriver, Colorado 80203 (303) 866-3581 APPLICANT RUDD CONSTRUCTION 0132 PARK AVE BASALT, CO 81621- (970) 927-9119 PERMIT TO CONSTRUCT A WELL 1095 WELL PERMIT NUMBER 250297 DIV. 5 WD38 DES. BASIN MD APPROVED WELL LOCATION GARFIELD COUNTY NE 1/4 SE 1/4 Section 35 Township 6 S Range 88 W Sixth P.M. DISTANCES FROM SECTION LINES Ft. from Ft. from UTM COORDINATES Northing: Section Line Section Line Easting: ISSUANCE OF THIS PERMIT DOES NOT CONFER A WATER RIGHT CONDITIONS OF APPROVAL 1) This well shall be used in such a way as to cause no material injury to existing water rights. The issuance of this permit does not assure the applicant that no injury will occur to another vested water right or preclude another owner of a vested water right from seeking relief in a civil court action. 2) The construction of this well shall be in compliance with the Water Well Construction Rules 2 CCR 402-2, unless approval of a variance has been granted by the State Board of Examiners of Water Well Construction and Pump Installation Contractors in accordance with Rule 18. 3) Approved pursuant to CRS 37-92-602(3)(b)(II)(A) as the only well on a tract of land of 43.82 acres described as that portion of the NE 1/4 of the SE 1/4, Sec. 35, Twp. 6 South, Rng. 88 West, 6th P.M., Garfield County, more particularly described on the attached exhibit A. This well is identified as the Parcel B Well. 4) The use of ground water from this well is limited to fire protection, ordinary household purposes inside not more than three (3) single family dwellings, the irrigation of not more than one (1) acre of home gardens and lawns, and the watering of domestic animals. 5) The maximum pumping rate of this well shall not exceed 15 GPM. 6) The return flow from the use of this well must be through an individual waste water disposal system of the non -evaporative type where the water is returned to the same stream system in which the well is located. 7) This well shall be constructed not more than 200 feet from the location specified on this permit. NOTE: Parcel Identification Number (PIN): 23-2187-354-00-145 NOTE: Assessor Tax Schedule Number: R007347 APPROVED DMW Receipt No. 0509413C 03 State Engineer By 05-14-2003 DATE ISSUED EXPIRATION DATE 05-14-2005 Tuesday, April 06, 2004 9:52 AM Wayne 5nelton 9/U-921-tsU1 p. u1 WELL CONSTRUCTIOOAND TEST REPORT STATE OF COLORADO, OFFICE OF THE STATE ENGINEER 111111 FOR OFFICE USE ONLY APPROVAL # OWS31-91.03 1. WELL PERMIT NUMBER 250297 2 Owner Name(s): Rudd Construction Mailing Address: 0132 Park Ave. City, State, Zip : Basalt, Co. 81621 Phone # : 970-927-9119 L WELL LOCATION AS DRILLED NE 1/4 SE 1/4 Sec: 35 Twp: 6 5 Range: 88 W DISTANCES FROM SEC. LINES 1511 ft. from South Sec. line and 325 ft. from East Sec. line OR Northing: Easting: SUBDIVISION: 29 Peaks LOT: B BLOCK: FILING (UNIT): STREET ADDRESS AT LOCATION 4. GROUND SURFACE ELEVATION ft. DRILLING METHOD Air Rotary DATE COMPLETED: 5/21/2003 TOTAL DEPTH: 160 DEPTH COMPLETION: 160 5. GEOLOGIC LOG 6. HOLE DIAMETER (in) PROM (ft) TO (11) Depth Type of Material (Size, Color. and Type) 9.0 0 40 40 160 000-020 Volcanics 6.5 020-160 Maroon Formation 7. PLAIN CASING OD (in) Kind Wall Size From (ft) To (ii) 7.0 Steel 0.240 -1 40 5.5 PVC 0.250 36 120 PERF. CASING : Screen Slot Size 5.5 PVC 0.250 120 160 Water Located: 120+ Remarks : 8. Filter Pack Material : Size . Interval : 9. Packer Placement Type : Depth . 10. GROUTING RECORD Material Amount Density Interval Placement Cement 5 sks 6 gal/sk 10-40 poured i 1. D1SINFI✓CTION : Type : HTH Amt. Used : 3 oz_ 12. WELL TEST DATA : () Check Box If Test Data Is Submitted On Supplemental TESTING METHOD : Air Compressor Static Level : 105 ft. Date/Time Measured 5/21/2003 Production Rate 15 gpm Pumping Level : Total ft. Date/Time Measured 5/21/2003 Test Length : 2 hours Test Remarks : 13.I have read the st¢tcmcnts made heroin anal Irstow tha eoutants thereof, and that they ets hue to my knowledge. (Pursuant to Section 24-4-1-4 (13)(a) CRS. the making of false statements cttsl.itutes perjtuy in the eccond do gr�te and is punishable sa a class 1 misdemeanor.) CONTRACTOR : Sh®lton Drilling Corp. Phone _ (970) 927-4182 Mailing Address : P.O. Box 1059 Basalt, Co. 81621 Lic, No. 1095 Name / Title (Please Type or Print) Wayne Shelton / President Signature Date 6/26/2003 Colonia o.prtesent of Public Health aad Fawaemmc LABORATORY & RADIATION SERVICES 8100 LOWRY BOULEVARD DENVER, CO 80230-6928 US MAIL PO BOX 17123 DENVER, CO 80217 WATER BACTERIOLOGY -1-0 Le_ I 11 SAMPLE INFORMATION: 0 COMMUNITY 0 NON -COMMUNITY PRIVATE 0 ROUTINE '®.FLAW 0 REPEAT FOR THE MONTH OF 4/ -SPECIAL PURPOSE 0 FINISHED iL/��EeI/I Et.) PWS ID NAM SYSTEM &'Ab //-5— CHLORINE RESIDUAL MG/L ADDRESS CITY COUNTY ORDERED ORDERED BY: (SAMPLE MAY NOT BE TESTED IF ALL INFORMATION IS NOT PROVIDED) FEE STAMP LAB 106 (07/97) (97v 9L5 -57 - PHONE NAME /COS 6,) �A;4711/1 ADDRESS 47--5-x/ \[Oob SP,z/A--'GTS, Ci .f'l&e" J CITY ; STATE i ZIP TEST ORDERED u STD SACT ❑ OTHER COLLECTED // DATE TIME BY ip/D//O�7A141:: / ❑ AM RECEIVED / ` 0 PM RESULTS: SEE REVERSE FOR ELA ON TOTAL COLIFORM ❑ PRESENT ABSENT MOST PROBABLE NO ❑ DENVER ANALYST COLIFORM/100ML AN • LYJ GRD. JCT. 72932214-22 P.O. Box 1908 1005 Cooper Ave. Glenwood Springs, CO 81602 RECEI JUL 0 6 2004 GARFIELD COUNTY BUILDING & PLANNING Z4NC414ELL4 4(111) 4550Cl4TES, Inc. ENGINEERING CONSULT4NTS Mr. Mark Bean Garfield County Planning Department 108 Eighth Street, Suite 201 Glenwood Springs, CO 81601 RE: Overview Subdivision Dear Mark: July 2, 2004 (970) 945-5700 (970) 945-1253 Fax In our letter report of June 24, 2004, we discussed the water supply for the proposed Overview Subdivision. At that time we had not received the water quality results from the lab. This report talks about the final water quality results and is to serve as a supplement to the June 24 report. Water Quality Water samples were collected during the pump test of the Overview Well and sent to ACZ Laboratories in Steamboat Springs for independent analyses. The lab tests included analyses for various inorganic chemicals, nitrate/nitrite, total dissolved solids (TDS) and some of the physical properties of the water. A total coliform bacteria sample was collected and sent to the state lab in Grand Junction for analysis. The coliform bacteria test indicates that coliform bacteria were absent from the sample. The result from the bacteria test is attached. Results of the analyses from ACZ Labs are also attached and are summarized in the table below: Analyte Lab Result Maximum Contam. Level (MCL) Units Arsenic 0.0017 0.05 mg/I Barium 0.381 2 mg/I Beryllium Not Detected 0.004 mg/I Cadmium Not Detected 0.005 mg/I Calcium 43.7 N/A mg/I Chromium Not Detected 0.1 mg/I Copper Not Detected 1-3 mg/I Iron 0.05 0.3 mg/I Lead Not Detected 0.015 mg/I Magnesium 7.5 N/A mg/I Manganese Not Detected 0.05 mg/1 Mercury Not Detected 0.002 mg/1 t • • Nickel Not Detected N/A mg/I Potassium 0.8 N/A mg/I Selenium Not Detected 0.05 mg/I Silver Not Detected 0.10 mg/I Sodium 5.2 N/A mg/I Thallium Not Detected 0.002 mg/I Alkalinity 147 N/A mg/I Chloride 2 250 mg/I Conductivity 249 N/A /.mhos/cm Fluoride 0.1 4 mg/I Hardness 140 N/A mg/I Nitrate 0.55 10 mg/I Nitrite Not Detected 1 mg/I pH 7.4 N/A pH Units Sulfate Not Detected 250 mg/I mg/I TDS 150 500 Turbidity 0.1 1 Nephelometric Units ote: Maximum Contaminant Levels are established by the Colorado Department of Public Health & Environment and the U. S. Environmental Protection Agency. As can be seen from the above table, for all of the analytes tested, none were above their respective MCLs. If you have any questions, please call our office at (970) 945-5700. Very truly yours, Zancanella and Associates, Inc. Thomas A. Zancanella, P.E. Bradley C. Pee , Geologist Attachments cc: Wayne Rudd Z:\97000's\97404 Rudd, Wayne\97404.08 Overview Subdivision\Bean-WaterQual.doc Parameter` ACZ Laboratories, Inc. 2773 Downhill Drive Steamboat Springs, CO 80487(800) 334-5493 Zancanella & Associates Project ID: RUDD/OVERVIEW Sample ID: OVERVIEW WELL Inorganic Analytical' Results, ACZ Sample ID: Date Sampled: Date Received: Sample Matrix: L46086-01 06/01/04 11:40 06/03/04 Drinking Water Metals Analysis EPA Method Result Quat XQ Units MDL PQL Date Arsenic, total recoverable Barium, total recoverable Beryllium, total recoverable Cadmium, total recoverable Calcium, dissolved Chromium, total recoverable Copper, total recoverable Iron, total recoverable Lead, total recoverable Magnesium, dissolved Manganese, total recoverable Mercury, total Nickel, total recoverable Potassium, dissolved Selenium, total recoverable Silver, total recoverable Sodium, dissolved Thallium, total recoverable Metals Prep M200.8 ICP -MS M200.7 ICP M200.3 iCP-MS M200.8 ICP -MS M200.7 ICP M200.8 ICP -MS M200.8 ICP -MS M200.7 ICP M200.8 ICP -MS M200.7 ICP M200.7 ICP M245.1 CVAA M200.7 ICP M200.7 ICP M200.8 ICP -MS M200.7 ICP M200.7 ICP M200.8 ICP -MS 0.0017 0.381 43.7 0.05 7.5 0.8 5.2 B u u u B u u u u B u u u mg/L 0.0005 0.003 06/25/04 20:49 mg/L 0.003 0.01 mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L 06/10/04 0:43 0.0005 0.003 06/25/04 20:49 0.0005 0.003 06/25/04 6:40 0.2 1 06/23/04 20:53 0.0005 0.003 06/25/04 6:40 0.003 0.01 06/25/04 6:40 0.01 0.05 0.0005 0.003 0.2 1 0.005 0.03 06/15/04 13:04 06/25/04 6:40 06/23/04 20:53 06/10/04 0:43 Analyst jb scp jb jb wfg jb jb scp jb wfg scp 0.0002 0.001 06/21/04 14:54 jjc 0.01 0.05 06/10/04 0:43 scp 0.3 1 06/10/04 11:47 wfg 0.0005 0.003 06/29/04 23:09 jb 0.005 0.03 06/17/04 9:47 0.3 1 06/24/04 15:51 0.0003 0.001 06/25/04 6:40 R� irrt: aiia' xa CTrit L' -f ` • mot t ry Total Recoverable Digestion Total Recoverable Digestion M200.2 ICP -MS M200.2 ICP 06/22/04 15:47 scp scp jb Icj 06/16/04 8:06 wfg REPIN.01.11.00.01 Please refer to Extended Qualifier Report for detail. L46086: Page 3 of 9 • • AZ Laboratories, Inc. 2773 Downhill Drive Steamboat Springs, CO 80487(800) 334-5493 Zancaneila & Associates Project ID: RUDD/OVERVIEW Sample ID: OVERVIEW WELL Inorganic Analytical Results ACZ Sample ID: L46086-01 Date Sampled: 06/01/04 11:40 Date Received: 06/03/04 Sample Matrix: Drinking Water Wet Chemistry Parameter EPA Method Result Qual. XQ Unites, MDL PQL Date,: Alkalinity as CaCO3 Bicarbonate as CaCO3 Carbonate as CaCO3 Hydroxide as CaCO3 Total Alkalinity Cation -Anion Balance Calculation Cation -Anion Balance Sum of Anions Sum of Cations SM2320B - Titration Analyst 147 mg/L 2 10 06/05/04 0:00 bf U U 147 mg/L 2 10 06/05/04 0:00 bf mg/L 2 10 06/05/04 0:00 bf mg/L 2 10 06/05/04 0:00 bf 0.0 % 07/01/04 0:00 3.0 meq/L 0.1 0.5 07/01/04 0:00 3.0 meq/L 0.1 0.5 07/01/04 0:00 Chloride M325.2 - Colorimetric 2 B mg/L 1 5 06/19/04 15:18 Color M110.1 - Colorimetric UH * Co/Pt 5 5 06/04/04 10:07 Conductivity @25C M120.1 - Meter 249 um hos/cm 1 10 06/05/04 12:58 Fluoride SM4500F-C 0.1 B mg/L 0.1 0.5 06/17/04 10:07 Hardness as CaCO3 SM2340B - Calculation 140 mg/L 1 7 07/01/04 0:00 Lab Filtration SM 3030 B 06/04/04 9:40 Lab Filtration & SM 3030 B 06/04/04 13:00 Acidification Nitrate as N, dissolved Calculation: NO3NO2 minus NO2 0.55 mg/L 0.02 0.1 07/01/04 0:00 calc Nitrate/Nitrite as N, M353.2 - Automated Cadmium 0.55 H mg/L 0.02 0.1 06/03/04 20:36 jjr dissolved Reduction Nitrite as N, dissolved M353.2 - Automated Cadmium UH * mg/L 0.01 0.05 06/03/04 18:43 Reduction pH (lab) M150.1 - Electrometric 7.4 H units 0.1 0.1 06/05/04 12:58 bf Residue, Filterable SM2540C - Gravimetric 180 mg/L 10 20 06/08/04 12:12 mah (TDS) @180C Sulfate M375.3 - Gravimetric U * mg/L 10 50 06/17/04 9:24 djb TDS (calculated) Calculation 150 mg/L 10 50 07/01/04 0:00 calc TDS (ratio - Calculation 1.20 07/01/04 0:00 calc measured/calculated) Turbidity M180.1 - Nephelometric 0.1 BH * NTU 0.1 0.5 06/04/04 10:26 bf calc calc calc kmc bf bf mah calc bd bd REPIN.01.11.00.01 " Please refer to Extended Qualifier Report for detail. L46086: Page 4 of 9 Colorado of Public' i h t and Erroroomeot LABORATORY & RADIATION SERVICES 8100 LOWRY BOULEVARD DENVER, CO 80230-6928 US MAIL PO BOX 17123 DENVER, CO 80217 WATER BACTERIOLOGY SAMPLE INFORMATION: 0 COMMUNITY 0 NON -COMMUNITY `PRIVATE ❑ ROUTINEAW 0 REPEAT FOR THE MONTH OF SPECIAL PURPOSE 0 FINISHED PWS ID /v,> /o/ aVI & ) NAME,gF SYSTEM CHLORINEAL MG/L ADDRESS CITY OUNTY COLLECTED DATE TIME J]-� BY 4 Pi/Dy"��oo �PM ss / ❑ AM RECEIVED f / 0 PM ORDERED BY: (SAMPLE MAY NOT BE TESTED IF ALL INFORMATION iS NOT PROVIDED) (97 2 )%1-1-5-- 57125 FEE STAMP LAB 106 (07/97) PHONE 2470 G' /4-,ci EL -c-.4 i7�S e, NAME /COS 6,1) ",-4 4/6 ADDRESS 4ZF hada SP,i,UcTS, eie e CITY / STATE / ZIP TEST ORDERED VI -STD BACT. 0 OTHER RESULTS: SEE REVERSE FOR ELA ON TOTAL COLIFORM 0 PRESENT ABSENT MOST PROBABLE NO 0 DENVER ANALYST COLIFORM/100ML AN GRD. JCT. • • Overview Subdivision, Garfield County, CO The parcel to be subdivided is owned by Wayne Rudd. The three co -applicants Steve Oger, Rick Oger and Gary Setness are long time employees of Rudd Construction. Upon Final Plat approval Wayne Rudd has agreed to sell the three lots at a greatly reduced price, so that these employees will have the ability to build their own homes. All three of the employees are renters, and have never owned homes in the Roaring Fork Valley. In all likelihood, this opportunity would be their only possibility of owning their own homes. It is anticipated that only one single family home and barn/accessory structure would be built on each. lot. This Subdivision will be served by the following utilities: Kinder Morgan Gas - Holy Cross Electric - Qwest Telephone - All of these utilities are currently available on the proposed Lot 3. It is not known if cable TV is available at this time. Utility easements to each lot will be provided on the final plat. The proposed lots will be served by one common drive, and a drive easement will be provided on the final plat. The proposed lots will be served by the existing well, and a well sharing agreement will be in place at the time of final plat. Sewage disposal will be accomplished with Individual Septic Disposal Systems. There are no rivers or streams on the site, thus the proposed development will have no impact on public waters. Development will occur primarily on the Southernmost part of the parcel, which is less steep than the topography to the North. Care will be taken to prevent erosion of any excavated areas. It is proposed that the 3 lot owners will have an undivided 1/3 interest in the common/agricultural lot. Aug 30 04 01:41p AUG 3 0 2004 District 1 970-945-1318 • Garfield County Road and Bridge, District 1 7300 Hwy 82, Glenwood Springs, CO 81601 970-945-1223 ph, 945-1318 fax Date: 08-30-04 To: Jim Hardcastle Building and Planning From: Bobby Branham Road and Bridge Dist. 1 Re: 8575 CR 115 Allow for a subdivision sketch plan oVeVV/eh/ With regards to this particular subdivision: Upon reviewing the above request Road and Bridge does not oppose the usage of a single driveway as an access for three residences. However, this existing driveway is only 20 feet wide. This width is inadequate for a three resident access. Road and Bridge recommends that the driveway be widened to 40 feet in order to accommodate the increased amount of traffic as compared to a single residence. All other aspect of the driveway area acceptable. The applicant states "A driveway permit off CR 115 is in place." This is not a true statement. A driveway permit was issued on or about April 15`h 2003. Driveway permits are only valid for a period of 30 days, and this permit in particular was issued under the pretence that it would be for a single family residence. No other permits have been issued; therefore, a new permit will be required. Bobby Branham Dist. 1 Road and Bridge p.1