Loading...
HomeMy WebLinkAbout1.0 Application• • TO: BOARD OF COUNTY COMMISSIONERS OF GARFIELD COUNTY. We, the undersigned petitioners,. wising to establish a Water and Sanitation District pursuant to law, herewith submit and file the within Service Plan pursuant to the Special District Control Act, C.R.S. 1963, as amended, 89-18-1, et seq: 1. NAME: The special district shall be known as the ROARING FORK WATER AND SANITATION DISTRICT. 2. DISTRICT BOUNDARY. The District boundary will be as shown on the attached map, Exhibit "A", and will contain approximately 450 acres. 3. POPULATION: It is estimated that the population of the District will ultimately be 1,150 persons and the within facilities are designed to serve this population. It should be pointed out that restrictive covenants in effect for the area included in the District limit the number of dwelling units to 360. 4. ASSESSED VALUATION: The assessed valuation of the proposed District when all improvements are constructed, is estimated at $4,500,00.00. 5. PRELIMINARY ENGINEERING SURVEY AND DESCRIPTION OF FACILITIES TO BE CONSTRUCTED: There is attached hereto as Exhibit B a pre -design study report prepared by Eldorado Engineering Company, Glenwood Springs, Colorado. Said report describes the facilities to be constructed, the service to be provided and sets out the estimated costs of construction, engineering and legal expenses and the expenses of organization of the proposed District. It is contemplated that the facilities will be constructed and financed in stages as the demand requires, however the estimated total cost for full development, including organization, is $379,575.00. • • 6. STANDARDS OF CONSTRUCTION: The water facilities will be constructed according to American Waterworks Association Design Criteria and in accordance with Colorado Department of Health Standards. The sewer facilities will be constructed according to standard engineering procedures and in accordance with the standards of the Colorado Department of Health. 7. PROPOSED FINANCING AND INDEBTEDNESS: It is estimated that approximately $100,000.00 will be financed by tap fees and hook-up fees. The balance will be financed through general obligation bonds to bear an estimated 91V, maximum interest per annum with a life of 30 years. It is contemplated that the initial bond issue will be purchased by the developer because of the limited initial market. A. Annual operating and maintenance costs are estimated at $12,000.00. B. Monthly service charges are estiamted at $15.00 per month per dwelling unit for both water and sewer service. Commercial usage to be based on number of water use facilities and sewage outlets. C. It is contemplated that a mill levy of approximately 15 mills should be sufficient for debt service, retirement and operating expense. THEREFORE, the undersigned petitioners respectfully request that the within service plan be heard as provided by law and that the Board adopt a resolution of approval of the within plan. Dated this 13th day of March, 1972. JAC0BS0 DIV RSIFIED, By Stuart Swidler Executive Vice -President. '7 / 1. / /%,/- E eCtor / ' Elector Elector . Elector • REPORT OF: PRE -DESIGN STUDY OF DOMESTIC WATER AND SANITARY SEWAGE SYSTEMS ROARING FORK RANCH DEVELOPMENT Q0 P.0 PE ELDORADO ENGINEERING COMPANY GLENWOOD SPRINGS, COLORADO 81601 FEBRUARY 25, 1972 Exhibit B • 1 I. INTRODUCTION. The following report illustrates the water and sewage system requirements to serve the proposed "planned unit development" of portions of the Roaring Fork Ranch east of Carbondale, Colorado. II. DESIGN CRITERIA. Computations in this report are based upon Phase I and ultimate dwelling unit and commercial unit densities as provided by the owner. These are as follows: Phase I Ultimate 60 dwelling units 4o room hotel 150 seat restaurant -bar 300 dwelling units 40 room hotel 150 seat restaurant -bar 6 small retail shops 1 automobile service station For purposes of calculation an average population of 3.2 people is assumed for each dwelling unit. III. UTILITY REQUIREMENTS The calculations (appendix i) of sewage treatment capacity and domestic water capacity requirements are self-explanatory. The results of the calculations are summarized in the following tabulation. Sewage Treatment Domestic Water Domestic Water Plant Capacity Supply Requirement Storage Requirement Phase I Development 25,800 g.p.d. Ultimate Development 109,600 g.p.d. • g.p.m. = gallons/minute g.p.d. = gallons/day 49.7 g.p.m. 160,338 gallons (71,568 g.p.d.) 205 g.p.m. 407,651 gallons (295,229 g.p.d.) • • IV. RECOMMENDATIONS. The following recommendations are made for the construction of utility systems in phases which will keep pace with the land development. 1. Sewage System (A) Phase I Development - construct a treatment plant with pre- treatment and post treatment for 110,000 g.p.d. capacity and construct aeration and clarification for 50,000 g.p.d. This will provide service for the equivalent of an additional 75.6 dwelling units before plant expansion is required. (B) When sewage treatment plant capacity increase is required add aeration and clarification for 60,000 g.p.d. (C) All main outfall sewer line constructed for Phase I Development should be designed for ultimate hydraulic loading. 2. Water System (A) Construct the infiltration gallery and pump station and chlorination for ultimate capacity during first phase construction. (B) All water mains constructed for Phase I Development should be designed for ultimate hydraulic requirements. (C) During Phase I Development, construct a 200,000 gallon domestic water storage tank. This will provide sufficient storage for the equiv- alent of an additional 60 dwelling units before additional storage is required. (D) When storage requirements exceed 200,000 gallons, construct an additional 200,000 gallon tank. V. CONSTRUCTION COST ESTIMATE Estimated costs for Phase I Water and Sewer System Construction were calculated based upon the recommendations in IV above. These estimated costs are tabulated in appendix ii and are summarized below: Water System Sewer System $84,375 8, 1+oo Estimated Total $169,775 VI. WATER AND SEWER SYSTEMS GENERAL PLAN The proposed locations of facilities discussed in this report are illustrated on the attached map. ROARING FORK RANCH SEWAGE 'TREATMENT WORKS - CAPACITY REQUIREMENTS A. FULL DEVELOPMENT CRITERIA 1. 300 dwelling units 2. Hotel - 40 rooms 3. Restaurant -bar 150 seats 4. 6 shops 5. 1 service station SEWAGE LOADING 1. 300 D.U. @ 3.2 P.E./D.U. 2. (40) @ 120 g.p.d./rm. 3. 150 seats 4 meals/day 4. 6 @ 500 g. p. d. service station 5. B. DEVELOPMENT PHASE I CRITERIA 1. 60 dwelling units 2. 40 room hotel 3. restaurant -bar 150 seats SEWAGE LOADING 1/29/72 @ 100 g.p.d./P.E. = 98,000 4,800 3 gal/meal (no breakfast) 1,800 3,000 2,000 TOTAL 109,600 1. 60 D.U. @ 3.2 P.E./D.U. @ 100 g.p.d./P.E. 2. 4o @ 120 g.p.d./rm. 3. 150 seats @ 4 meals/day @ 3 gal/meal TOTAL P.E. = Population Equivalent D.U. = Dwelling Unit 19,200 4,800 1, 800 25,80o • 1 ROARING FORK RANCH 1/29/72 DOMESTIC WATER REQUIREMENT'S A. FULL DEVELOPMENT CRITERIA 1. 300 dwelling units 2. Hotel - 40 room 3. Restaurant -bar 150 seat 4-. 6 shops 5. 1 service station WATER REQUIREMENTS (Average Day) 1. 300 D.U. @ 3.2 PE/DU @ 150 g.p.d./PE _ .144,000 2. 40 room @ 125 g.p.d./rm. 5,000 3. 150 seats 4/meal/day/seat G10 gal/meal 6,000 4. 6 @ 1000 6,000 5. service station 3,000 TOTAL AVERAGE DAY 164,00o gal. FLAW REQUIREMENTS Average Day 164,000 1440 = 113.9 g.p.m. Peak Day _180 %Average Day = (113.9) (1.8) = 205.0 g.p.m. = 295,229 g.p.d. = 0.4576 c.f.s. Minimum Water Supply 205 g.p.m. STORAGE REQUIREMENTS 1. Equalizing Storage = 30% of Peak Day Use = (295, 229) (.30) = 88,569 gal. 2. Fire Storage Required fire flow (National Board Fire Underwriters) Q= 1020 (1 - .01 P ) P = Population in 1000 P= .96 i=.98 Q = (102o) (.98) (9902) = 989.8 g.p.m. Fire Storage = Fire Flow for 4 Hours = (4) (60) (989.8) = 237,552 gal 3. Emergency Storage = 25% of total of all other storage Equalizing 88,569 Fire 237 552 326,121 (.25) (326,121) __§.1L532 Recommend total storage construction to be 400,000 gallons. B. DEVELOPMENT PHASE I CRITERIA 1. 60 dwelling units 2. 40 room hotel 3. 150 seat reastaurant WATER REQUIREMENTS (Average Day) 1. 6o D.U. @ 3.2 P.E./D.U. @ 150 g.p.d. 28,800 2. 40 @ 125 g.p.d. 5,000 3. 150 seats 4 meals/seat @ 10 gal/meal 6,000 TOTAL AVERAGE DAY 39,800 • FLOW REQUIREMENTS Average Day 300 = 27.6 g.p.m. Peak Day= 180% Average Day = (27.6) (1.8) = 49.7 g.p.m. = 71,568 g.p.d. = 0.111 c.f.s. Minimum Water Supply =.49.7 g.p.m. STORAGE REQUIREMENTS 1. Equalizing Storage = 30% of Peak Day Use = (.30) (71, 568) = 2122112_5111:. 2. Fire Storage Required fire flow (National Board Fire Underwriters) Q 10201P (1 -.01 P ) P. Population in 1000 P=.192 _ .438 Q. 1020 (.438) (.996) = 445 g.p.m. Fire Storage = Fire Flow for 4 hours = (4) (60) (445) = 106,800 gal. • 3. Tnergency Storage = 25% of total of all other storage Equalizing Fire 21, x+70 106.r, 800 128, 270 (.25) (128,270) 32,068 160,338 Recommended First Storage = 200,000 gallons. appendix ii 411 • ROARING FORK RANCH - UTILITY CONSTRUCTION COST ESTIMATE 3/2/72 PHASE I - WATER SYSTEM (A) Pipeline 8" ductile iron 3300 1.f. @ 8.75 28,875 6" ductile iron 240 1.f. @ 8.00 1,920 fire hydrants, 5 @ 650.00 3,250 (B). Storage Tank tank base and valving 200,000 gallon steel tank (C) Supply Development infiltration gallery chlorination pumping equipment pump station housing pump to tank controls 5% miscellaneous and contingency design engineering Total Water PHASE I - SEWAGE SYSTEM 4,000 24,500 3,000 2,500 3,800 1,200 1,600 74,645 3,730 6,00o $84,375 8" sewer line 3610 1.f. @ 7.00 - 25,270 manholes 15 @ 350.00 5,250 2 creek crossings special treatment, 500 @ 1,000 treatment plant 5% miscellaneous and contingency design engineering Total Sewage 42, 000 73,520 3,68o 8, 200 $85,400 • • ESTIMATED WATER AND SEWER SYSTEM COSTS, PHASE 2 THROUGH FULL DEVELOPMENT. WATER: SEWER: 6" 4140 1.f. at $8.00 8" 1750 1.f. at $8.75 200,00 gallon storage 15 fire hydrants at $650.00 $ 33,120.00 15,313.00 28,000.00 9,750.00 $ 86,183.00 5 '/ miscellaneous and contingencies 4,317.00 Design Engineering $ 90,500.00 7,200.00 Estimated Total $ 97,700.00 Plant expansion to 110,000 g.p.d. 5900 1.f. 8" sewer at $7.00 20 manholes at $350.00 '5 °% Miscellaneous and contingencies Design engineering Estimated Total $ 40,000.00 41,300.00 7,000.00 $ 88,300.00 4,400.00 $ 92,700. 00 7,400.00 $100,100.00 • • SUMMARY ESTIMATED COST FOR FULL DEVELOPMENT WATER SYSTEM Phase One Phase Two through Full Development SEWAGE SYSTEM Phase One Phase Two through Full Development TOTAL WATER AND SEWAGE -Legal and Organizational First year operation and maintenance $ 84,375.00 97,700.00 $ 182,075.00 $ 85,400.00 100,100.00 $ 185,500.00 $ 367,575.00 3,000.00 9,000.00 $ 379,575.00 • • REPORT OF: PRE -DESIGN STUDY OF DOMESTIC WATT AND SANITARY SEWAGE SYSTEMS ROARING FORK RANCH DEVELOPMENT ELDORADO ENGINEERING COMPANY GLENWOOD SPRINGS, COLORADO 81601 FEBRUARY 25, 1972 I. INTRODUCTION. The following report illustrates the water and sewage system requirements to serve the proposed "planned unit development" of portions of the Roaring Fork Ranch east of Carbondale, Colorado. II. DESIGN CRITEEIA. Computations in this report are based upon Phase I and ultimate dwelling unit and commercial unit densities as provided by the owner. These are as follows: Phase I 60 dwelling units 40 room hotel 150 seat restaurant -bar Ultimate 300 dwelling units 40 room hotel 150 seat restaurant -bar 6 small retail shops 1 automobile service station For purposes of calculation an average population of 3.2 people is assumed for each dwelling unit. III. UTILITY REQUIREMENTS The calculations (appendix i) of sewage treatment capacity and domestic water capacity requirements are self-explanatory. The results of the calculations are summarized in the following tabulation. Sewage Treatment Domestic Water Domestic Water Plant Capacity Supply Requirement Storage Requirement Phase I Development 25,800 g.p.d. Ultimate Development 109,600 g.p.d. g.p.m. = gallons/minute g.p.d. = gallons/day 49.7 g.p.m. 160,338 gallons (71,568 g.p.d.) 205 g.p.m. 1+07,651 gallons (295,229 g.p.d.) 1 • IV. RECOMMENDATIONS. The following recommendations are made for the construction of utility systems in phases which will keep pace with. the land development. 1. Sewage System (A) Phase I Development - construct a treatment plant with pre- treatment and post treatment for 110,000 g.p.d. capacity and construct aeration and clarification for 50,000 g.p.d.. This will provide service for the equivalent of an additional 75.6 dwelling units before plant expansion is required. (B) When sewage treatment plant capacity increase is required add aeration and clarification for 60,000 g.p.d. (C) All main outfall sewer line constructed for Phase I Development should be designed for ultimate hydraulic loading. 2. Water System (A) Construct the infiltration gallery and pump station and chlorination for ultimate capacity during first phase construction. (B) Allwater mains constructed for Phase I Development should be designed for ultimate hydraulic requirements. (C) During Phase I Development, construct a 200,000 gallon domestic water storage tank.. This will provide sufficient storage for the equiv- alent of an additional 60 dwelling units before additional storage is required. (D) When storage requirements exceed 200,000 gallons, construct an additional 200,000 gallon tank. V. CONSTRUCTION COST ESTIMATE Estimated costs for Phase I Water and Sewer System Construction were calculated based upon the recommendations in IV above. These estimated costs are tabulated in appendix ii and are summarized below: Water System Sewer System $84,375 B5, Loo Estimated Total $169,775 VI. WATER AND SEWER SYSTEM GENERAL PLAN The proposed locations of facilities discussed in this report are illustrated on the attached map. 411 appendix i • ROARING FORK RANCH 1/29/72 SEWAGE TREATMENT WORKS - CAPACITY REQUIREMENTS A. FULL DEVELOPMENT CRItr1 RIA 1. 300 dwelling units 2. Hotel - 40 rooms 3. Restaurant -bar 150 seats 4. 6 shops 5. 1 service station SEWAGE LOADING 1. 300 D.U. @ 3.2 P.E./D.U. @ 100 g.p.d./P.E. . 98,000 2. (40) @ 120 g.p.d./rm. 4,800 3. 150 seats 4 meals/day @ 3 gal/meal (no breakfast) 1,800 4. 6 @ 50o g.p.d. 3,000 5. service station 2,000 TOTAL 109,600 B. DEVELOPMENT PHASE I CRI'Pi RIA 1. 60 dwelling units 2. 40 room hotel 3. restaurant -bar 150 seats SEWAGE LOADING 1. 60 D.U. @ 3.2 P.E./D.U. @ 100 g.p.d./P.E. 19,200 2. 40 @ 120 g.p.d./rm. 4,800 3. 150 seats @ 4 meals/day @ 3 gal/meal 1,800 TOTAL 25,800 P.E. = Population Equivalent D.U. = Dwelling Unit ROARING FORK RANCH 1/29/72 DOMESTIC WATER REQUIREMENTS A. FULL DEVELOPMENT CRITERIA 1. 300 dwelling units 2. Hotel - 40 room 3. Restaurant -bar 150 seat 4. 6 shops 5. 1 service station WATER REQUIREMENTS (Average Day) 1. 300 D.U. @ 3.2 PE/DU @ 150 g.p.d./PE _ 144,000 2. 40 room @ 125 g.p.d./rm. 5,000 3. 150 seats 4/meal/day/seat 010 gal/meal 6,000 4. 6 @ 1000 6,000 5. service station 3,000 TOTAL AVERAGE DAY 164,000 gal. FLOW REQUIREMENTS Average Day 16it0000 = 113.9 g.p.m. Peak Day =180 %Average Day = (113.9) (1.8) = 205.0 g.p.m. 295,229 g.p.d. = 0.4576 c.f.s. Minimum Water Supply 205 g.p.m. STORAGE REQUIREMENTS 1. Equalizing Storage = 30% of Peak Day Use = (295,229) (.30) = 88,569 gal. 2. Fire Storage Required fire flow National Board Fire Underwriters) Q = 1020 'IP (1 - .01 P ) P = Population in 1000 P= .96 IF_ .98 Q = (1020) (.98) (,9902) = 989.8 g.p.m. Fire Storage = Fire Flow for 4 Hours = (4) (6o) (989.8) = 237,552 gal • • 3. Emergency Storage = 25% of total of all other storage Equalizing 88,569 Fire 237 552 326,121 (.25) (326,121) _21125.22 7, 51 Recommend total storage construction to be 400,000 gallons. B. DEVELOPMENT PHASE I CRITERIA 1. 60 dwelling units 2. 40 room hotel 3. 150 seat reastaurant WAIEE REQUIREMENTS (Average Day) 1. 60 D.U. @ 3.2 P.E./D.U. @ 150 g.p.d. 28,800 2. 40 @ 125 g.p.d. 5,000 3. 150 seats 4 meals/seat @ 10 gal/meal 6,000 TOTAL AVERAGE DAY 39,E FLOW REQUIREMENTS Average Day �39 800 141 = 27.6 g.p.m. Peak Day_ 180% Average Day = (27.6) (1.8) = 49.7 g.p.m. = 71,568 g.p.d. = 0.111 c.f.s. Minimum Water Supply = 49.7 g.p.m. STORAGE REQUIREMENTS 1. Equalizing Storage = 30% of Peak Day Use = (.30) (71, 568) = 21,470 gal. 2. Fire Storage Required fire flow (National Board Fire Underwriters) Q = 1020 -FP— (1 -.01 P ) P = Population in 1000 P = .192 _ .438 Q = 1020 (.438) (.996) = 445 g.p.m. Fire Storage = Fire Flow for 4 hours = (4) (60) (445) = 106,800 gal. • • 3. Emergency Storage . 25% of total of all other storage Equalizing 21,470 Fire 106 800 125,270 (.25) (128,270) 32,068 160,338 Recommended First Storage . 200,000 gallons. appendix ii ROARING FORK RANCH - UTILITY CONSTRUCTION COST ESTIMATE PHASE I - WATER SYSTEM 3/2/72 (A) Pipeline 8" ductile iron 3300 1.f. @ 8.75 28,875 6" ductile iron 240 1.f. Q 8.00 1,920 fire hydrants, 5 @ 650.00 3,250 (B) Storage Tank tank base and valving 4,000 200,000 gallon steel tank 24,500 (C) Supply Development infiltration gallery chlorination pumping equipment pump station housing pump to tank controls 5% miscellaneous and contingency design engineering Total Water PHASE I - SEWAGE SYSTEM 3,000 21500 3,800 1,200 1, 600 74,645 3,730 6,000 $84,375 8" sewer line 3610 1.f. @ 7.00 25,270 manholes 15 @ 350.00 5,250 2 creek crossings special treatment, 500 1,000 treatment plant 5% miscellaneous and contingency design engineering Total Sewage 42,000 73,520 3,680, 8,200 $85,40o