HomeMy WebLinkAboutObservation of Pit Excavation Soils Report 10.05.16...
H-P~'KUMAR
Gcotochnical Engineering ! Engineering Geology
Ma terials Testing I Environmenlal
5020 County Road 154
Glenwood Springs, CO 81601
Phone: (970) 945-7988
Fax: (970) 945-8454
Email: hpkglenwoodOkumarusa.com
Office Locations: Parker, Glenwood Springs, and Silverthome, Colorado
October 5, 2016
WRW Log Works
Attn: Whit Whitaker
I02 Deer Valley Drive
New Castle, Colorado 8164 7
(wrw3@hotmail .com)
Project No. 16 -7-376
Subject: Observation of Pit Excavations , Proposed Indoor Riding Arena, 893 County Road
I 02, Garfield County, Colorado
Dear Mr. Whitaker:
As requested, a representative of HP/Kumar observed pit excavations at the subject site on
August 26, 2016 to evaluate the soils exposed for foundation support . The findings of our
observations and recommendations for the foundation design are presented in this repon. The
services were performed in accordance with our agreement for professional engineering services
to WRW Log Works, dated August 29, 2016. H-P Geotech (now H-P/Kumar) previously
performed a geologic site assessment and preliminary geotechnical study for the proposed Hunt
Ranch Subdivision and reported our findings June 9, 2006, Job No. l 06 0033.
The proposed indoor arena will be 120 feet by 240 feet and located about 100 feet north of
existing barns and north of County Road 102. About one foot of topsoil had been removed from
the arena area and a pit excavated at each building corner prior to our site visit.
At the time of our visit to the site, four explor,uory pil'i had been dug about 4 feet below the
adjacent ground surface. The soils exposed in the pit consisted of medium stiff, sandy silty clay.
Results of swell-consolidation testing performed on samples taken from the pits, shown on
Figures I, 2 and 3, indicate the soils huve low compressibility under light loading at existing
moisture conditions and low to moderate collapse potential (settlement under constant load)
when wetted. The samples had high compressibility under increased loading af1er wetting. No
free water was encountered in the pit excavations and the soils were slightly moist to moist.
Considering the conditions exposed in the exploratory pits and the nature of the proposed
construction, spread footings placed on the undisturbed natural soil designed for an allowable
soil bearing pressure of 1,500 psf should be adequate for support of the proposed indoor arena.
The exposed soils tend to compress when wetted and there could be some post-construction
settlement of the foundation if the bearing soils become wet. Care ~hould be taken 10 prevent
wetting of the subgrade soils by providing good surface drJinage around the ouli!iide of the
building. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for
columns. Loose and disturbed soils in footing areas should be removed and the bearing level
WRW Log Works
October 5, 2016
Page2
extended down to the undisturbed natural soils. The bearing soils should be protected against
frost and concrete should not be placed on frozen soils. Exterior footings should be provided
with adequate soil cover above their bearing elevations for frost procection . Continuous
foundation walls should be reinforced top and bottom to span local anomalies such as by
assuming an unsupponed length of at least 12 feet. Structural fill placed within floor slab areas
can consist of the on-site soils compacted to at least 95% of standard Proctor density at a
mo isture content near optimum. Backfill placed around the structure should be compacted and
the surface graded to prevent ponding within al least 10 feet of the building.
The recommendations submitted in this Jetter are based on our observation of the soils exposed
within the exploratory pits and do not include deep subsurface exploration to evaluate the
subsurface conditions within the loaded depth of foundation influence. This study is based on
the assumption that soils beneath the footings have equal or better suppon than those exposed.
The risk of foundation movement may be greater than indicated in this report because of possible
variations in the subsurface conditions . In order to reveal the nature and extent of variations in
the subsurface conditions below the excavation, drilling would be required. It is possible the
data obtained by subsurface exploration could change the recommendations contained in this
letter. Our services do not include determining the presence, prevention or possibility of mold or
other biological contaminants {MOBC) developing in the future. If the client is concerned about
MOBC, then u professional in this special field of practice should be consulted.
If you have any questions or need further assistance , please call our office.
Sincerely,
Louis Eller
Reviewed by:
LEE/ksw
attachments
H -P ~KUMAR Project No. 16-7-376
·-.
Moisture Content = 8.6 percent
Dry Density ... 87 pcf
0 Sample of: Sandy Silty Clay -~ From: Pit at Southwest Corner at 2 Feet -r--,... ,.. "( }
1
2
--3 ~ -./
~ v Compression
/ .._. ~
_ ...
--upon
4 wetting
5
ii.
c 0
"iii
Cl) 6 •
~ \ c.
E
0 7 u
\ 8
9
10 \
11 \
12 \
'
13 .:\
14 \
15 \
' 16
p
01 10 10 100
APPLIED PRESSURE -kSf
16-7-376 H-P~KUMAR SWELL-CONSOLIDATION TEST RESULTS Figure 1 G-: !..:.:r:tc.rii ~r: :-t~.,..,: re .. "~~ 1f'Wl ~:-:-:
P.t.,,:u; •1'\ t.;:::.itr; I \:r\1,:Jf':nt:ti:..
Moisture Content = 14.0 percent
Dry Density = 9 1 per
'
Sample of: Sandy Silty Clay
From : Pit at Southwest Corner al 4 Feet
0 ---i""-.. ~ i
1 !"-.,....
...
r..... r-:'11
2
Compression
upon
[...----~ v ... '"' wetting ..... 3 ,, ~
~ t:-i.-
4
I
5 \
\ t;e.
c 6 0
\ iii
UI
(II
0. 7 E
0
(.)
8
'
9 \
10 \
\
11 •
12 \
' 13
14 \ ,
15
01 1.0 10 100
APPLIED PRESSURE • ksf
16-7-376 H-P~KUMAR SWELL-CONSOLIDATION TEST RESULTS Figure 2
Moisture Content = 15.7 percent
Dry Density = 94 pcf
Sample of: Sandy Silty Clay
From: Pit al Northeast Corner al 3 }'2 Feet
0
r---'"'Ii)
~ 1
Compression ~ I< i.-~ g ........ upon 'in ~welting ~ 2 a " ~ I\ u 3
~ ,
4 \
'
5 \
' 6 ~
01 1.0 10 100
APPLIED PRESSURE • ksf
16-7-376 H-P~KUMAR SWELL-CONSOLIDATION TEST RESULTS Figure 3
H-P~KUMAR
TABLE1
SUMMARY OF LABORATORY TEST RESULTS
Project No. 16-7-376
SAMPLE LOCATION NATURAL NATURAL GRADATION ATTERBERG LIMITS UNCONFINED PERCENT
PIT MOISTURE DRY GRAVEL SAND PASSING LIQUID PLASTIC COMPRESSIVE
DEPTH CONTENT DENSITY N0.200 LIMIT INDEX STRENGTH SOIL lYPE
(%) (•/o)
(ft) (%) fncn
SIEVE
1%\ 1%\ fPSFl
SW 2 8.6 87 Sandy Silty Clay Comer
4 14.0 91 Sandy Silty Clay
NW 3 12.8 92 3.000 Sandy Silty Clay Corner I
NE 3 1h 15.7 94 92 Sandy Silty Clay Comer