Loading...
HomeMy WebLinkAboutObservation of Excavation 05.12.16~btech HEPWORTH-PAWLAK GEOTECHNICAL May 12, 2016 I Tom Re4d 635 East 4th Street Road Eaton, Co. 80615 (mrman635 @ms n.com) Hep1n1r1h-l'.11dak Geol<·dum.11, lnL 5020 County Road I 54 Cilet11rn<1d Spring,, Color;1do 0 l 6l) I Phone: 970-945-798S F.t\: 970-945-0454 L'llla1I : hpgl•o11hpgentt'L h.uim Job No. 116 177A Subject: Observation of Excavation, Proposed Residence, Lot 2, Overview Subdivision, 8382 County Road 115, Garfield County, Colorado Dear Mr. Reed: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the excavation at the subject site on May 9, 2016 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. We previously conducted a subsoil study for design of foundations at the site and presented our findings in a report dated July 31, 2007, Job No. 107 0440. The proposed residence will be one story wood frame construction above a walkout basement. Basement floor will be slab-on-grade. At the time of our visit to the site, the foundation excavation had been cut in one level from 4 V2 to 7 feet below the adjacent ground surface with a small stepped down area at the southwest corner. The soils exposed in the bottom of the excavation consisted of clayey sandy gravel with cobbles and boulders. The results of a gradation analysis performed on a sample of clayey sandy gravel with cobbles (minus 5 inch fraction) obtained from the site are presented on Figure 1. No free water was encountered in the excavation and the soils were slightly moist to moist. The soil conditions exposed in the excavation are consistent with those previously encountered on the site and suitable for support of spread footings designed for the recommended allowable bearing pressure of 1,500 psf. Loose and disturbed soils should be removed in the footing areas to expose the undisturbed natural soils. Other recommendations presented in our previous report which are applicable should also be observed. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and the previous (limited) subsurface exploration at the site. Variations in the subsurface conditions below the excavation could increase the risk of foundation movement. We should be advised of any variations Parker 303-841-71I9 • Cnlor,11..lo Springs 7 l 9~633~5562 • Silverthorne 970-468-1989 Tom Reed May 12, 2016 Page 2 encountered in the excavation conditions for possible changes to recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH -PAWLAK GEOTECHNICAL, INC. Reviewed by: ~~·~ ~//~·~,~\-~1-~-~E -~~~~~-: ·\ -f: (.j '<'-.v ·.-0' l ·{ "'-' 7~ ... Daniel E. Hardin, P.E.~! :,D •·44 '13 z: ~ ··".._;: .. t;/i--; .. ffv. .. v--· . ~i:.3 ..... ,',~(.,· LEE/k '<,;_~,,.<', ..... ,' '~~ ... ' sw ~-!ss~·----· \\:>", ~ attachments Figure 1 -Gradation Test Results cc: Glenwood Structural & Civil -Adolfo Gorra (!! .... c@ s o 12 ri~.net ) Job No. 116 177A • 0 w z < ..... w c:: t-z L&J u c:: w a_ HYDROMETER ANALYSIS S EVE ANAL YS S CLEAR SQUARE OPENINGS I 24 1 7HR TIME READINGS I US STANDARD SERIES I O 45 ~~ 15 MIN 60MIN19MIN 4 MIN. 1 MIN #200 #100 #50 #30 #16 #6 #4 3/B' 3/4' 11/2' 3' 5·5• a· lOO 10 20 30 40 50 60 70 BO 90 100 001 002 005 009 019 CLAY TOSI.I GRAVEL 68 % LIQUID LIMIT ~ ~ ~ ~ '~ 300 ,600 1.18 2 36 4 75 95 190 37.5 12 .5 76 2 152 203 127 .037 .074 150 D tAMETER OF PARTICLES IN Mi!.L IMETERS SA Ml I WlDIUtl GRA\1'! I COOBH S .,~ I ~. SAND 15 % SILT AND CLAY 17 % % PLASTICITY INDEX % SAMPLE OF: Clayey Sandy Grave f with Cobbles FROM : Bottom of Excavatton, East Side 90 80 70 60 50 40 30 20 10 0 (.!) z i7.i (/) < a_ t-z L&J u c:: w a_ 116177A o6'~ GRADATION TEST RESULTS Figure 1 HEPWOR'TM-PAWLAK GEO'TECHNICAL