HomeMy WebLinkAboutElectrical Inspection ReportsInspection Report Page I (if 1 COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT /-CORRECTION NOTICE Date Received: 10-NOV-16 Permit Number: 794048 Contractor/Hom eOwner: Address: Type of Inspection: Action: Canyon Electric 375 County Road 352 Final Rejected Comments or Corrections: Partial Final Inspection on Office Areas Ok electrically to move furniture in 1) 300.7A Raceways exposed to different temperatures are required to be sealed at boundary; preferrably on colder side. Conduits for outdoor A1C units. 2) 110.36 Building has a light control panel. Some wall switches work, others do not. 3) 110.38 Emergency lighting transfer switch in hallway does not work. 4) Missing receptionist counter receptacles. 5) Missing south fireplace room floor boxes. Inspectors Name: Norman Feck Phone Number: 303-869-3442 Date: 14-NOV-16 vvLVlZnIIV 01111 L [:LCC, I MR -AL tiUAKU DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 haps://www.dora.state.co.us/pls/real/Ep_Web Inspection GUI.Process Page 1 111 712016 Inspection Report Page 1 of I COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT 1 CORRECTION NOTICE Date Received: 10-NOV-16 Permit Number: 794048 ContractorlHom eOwner: Address.- Type ddress:Type of Inspection: Action: Canyon Electric 375 County Road 352 Rough In Rejected Comments or Corrections: Complete Rough Inspection (Above grid and service) 1) $ 50 re -inspect fee FYI - Arc flash stickers required on equipment with overcurrent protection devices. 1) 300.21 Fire caulkiputty any sleeves through fire walls See 11/07!2016 inspection report, 2) 250.248 Main Bonding Jumper missing in service disconnect, 3) 250,80, 250,92A, 408.40 Service raceways and enclosures shall be bonded. Missing ground bushings on raceways between service disconnect enclosure and CT can. 4) 250.24A1, 250.50 All availabe building grounding electrode conductors shall connect to grounded service conductor at any accessible point between supply and termination point of grounded conductor in service disconnect. Missing ufer, metal water pipe, building steel and other? at service disconnect. 5) 230.70E Each service disconnect shall be labeled as a service disconnecting means. 6) 110,24A Provide available fault current value and date at service. See 04/14/2016 inspection report on service Inspectors Name: Norman Feck Phone Number: 303-869-3442 Date: 14-NOV-16 VULUMMUU b I A I t tLt41 KILAL UUAHU DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 https:Hw%vw.dora,state.co.uslplslreal/Cp Web_Inspection GUI.Process4Page H/17/2016 Inspection Report Page I or I COLORADO STATE ELECTRICAL BOARD INSPECTION REPORT 1 CORRECTION NOTICE Date Received: 01-NOV-16 Contractor/Homeowner: Address: Type of Inspection: Action: Permit Number: 794048 Canyon EIectric 375 County Road 35? Rough In Partial Comments or Corrections: Above Grid Inspection Ok other than areas mentioned in corrections. Leave correction areas open, ok to drop the other grid files, electrically. 1) 300.22C1 Low volt wire terminals must be plenum rated or placed in a metal box. 2) "Line/Break" room at west end has T stat wire in line voltage junction box and spans this room to outdoor A1C units. 3) 300.21 Fire caulk/putty conduit sleeves through any fire walls Inspectors Name: Norman Feck Phone Number: 303-869-3442 Date: 02-NOV 16 %,vLvnnuv .71 A I C CLGI, 1 KJUAL tiUAKU DEPARTMENT OF REGULATORY AGENCIES 1580 Logan St. Suite 550 Denver, Colorado 80203-1941 Phone: (303) 894-2985 hltpsa/www.dorn.state.co.us/pis/real/Cp_Weh_Inspection_GUI.Process_page 11/17, 2016 COLORADO STATE ELECTRICAL BOARD 1560 Broadway, Suite 1350 Denver, CO 80202 Inspection Report Date Inspected: 1112112016 Permit #: 794048 Permit Holder: Canyon Electric Steven Bergman 2912 1-70 Business Loop Grand Junction 81504 Phone: (970) 248-9312 Fax: Email: steve@canyonelec.biz Site: 375 County Road 352 Rifle, Garfield County, Owner: Atlantic Aviation Status: Accepted Inspection Type: Final NEW COMMERCIAL Inspector: Norman Feck 303-869-3442 Corrections: Comments: