HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-01-17-4543
Julio Sandoval -New S.F. Residence
50 Cliffrose Way, Glenwood Springs
Pinyon Mesa -Lot 45
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (1.R.C.)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (1.E .C.C.)
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY BUILDING REQUIREMENTS AND
DETAILED DESCRIPTION OF NUMERIC NOTATIONS AS REDLIN ED ON DRAWINGS.
3) ALL STRUCTURES MUST BE FULLY CONTAINED WITHIN PLATTED BUILDING ENVELOPE
INCLUDING ROOF OVERHANGS, DECKS & PROJECTIONS. A LOT IMPROVEMENT SURVEY,
SEALED BY A COLORADO LICENSED SURVEYOR, IS REQUIRED AT FOUNDATION
INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH THIS REQUIREMENT.
4) PLANS APPROVED FOR UNFINISHED BASEMENT. IN THE EVENT OF FUTURE BASEMENT
FINISH, MAXIMUM TOTAL HABITABLE AREA NOTTO EXCEED 3,294 SQUARE FEET (PER
PLAT NOTE).
5) OPEN-HOLE SOILS REPORT REQUIRED AT FOOTING INSPECTION TO VERIFY 1200 PSF
SOILS BEARING CAPACITY.
6) RETAINING WALLS GREATER THAN 4-FOOT HEIGHT SHALL BE ENGINEERED AND SEALED
BY A COLORADO LICENSED PROFESSIONAL ENGINEER.
7) PROVIDE ROOF TRUSS SHOP DRAWINGS FOR INSPECTOR REVIEW AT FRAMING
INSPECTION.
8) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION . ELECTRICAL
FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY .