HomeMy WebLinkAboutOWTS Design CalculationsOWTS DESIGN CALCULATIONS: 43.6.A.4.a: Design flow values and strengths for commercial systems shall be determined from Table 6-2: Table 6-2: Employees Avg GPD BOD5 in Lbs per day Average Daily Flow (GPD) Average Daily BOD5 (Lbs) Office buildings per employee per 8 - hour shift 6 15 0.06 90 0.36 Septic Tank Size: Design Size (Gal): 48 Hours minimum detention 180 1000 Soil Treatment Area: = [Design Flow (GPD)] / [LTAR (GPD per sq.ft.)] Soil Type Perc Rate LTAR - Treatment Level 1 Soil Treatment Area [SF]: LTAR - Treatment Level 2N Soil Treatment Area [SF]: 1- Sand, loamy sand 5 to 15 0.8 112.5 0.9 100 2 - Sandy Loam, Loam, Silt Loam 16 to 25 0.6 150 0.7 128.5714286 2A - Sandy Loam, Loam, Silty clay Loam 26 to 40 0.5 180 0.5 180 Soil Characteristics Determined by Gradation Analysis conducted by HP Kumar and Documented in 10-10- 2016 Report: Content of Rock (> 2 mm) by Weight: 57% Content of Sand (< 2mm and >0.075 mm) 30% Soil Type per Table 10-1 Type 0 Soil Type of Soil < 2mm. Type 1 Proposed Treatment Level: TL1 Minimum 3 -ft deep unlined sand filter required LTAR [per 11.C.2.a.(4)(i)] (GPD/SF) 1.0 Check of Sec. 11.C.2.c(3): LTAR for Receiving Soil (Type 1) for TL3 0.9 Design LTAR: 1.0 Design Flow (GPD) 90 Soil Treatment Area [SF]: 90 G:\93164\2016\Design\OWTS\OWTS CALCS - 20161017.xls: OWTS CALCS - 20161017.xls Page 1 of 2 OWTS DESIGN CALCULATIONS: Adjustments to Soil Treatment Area: Adjusted Soil Treatment Area [SF]: Adjustment for Bed Configuration with Pressure Dosing: 1.0 90 Maximum Bed Width [ft]: 43.10.E.2.f.(1) 12 Minimum Length of Bed [ft]: 7.5 Designed Bed Width [ft]: 8 Designed Bed Length [ft]: 11.25 Area Adjustment for Factor of Safety: 1.2 Bed Length with Factor of Safety: 13.5 G:\93164\2016\Design\OWTS\OWTS CALCS - 20161017.xls: OWTS CALCS - 20161017.xls Page 2 of 2