HomeMy WebLinkAbout3.0 Staff ReportPROJECT NAME:
• 1
PROJECT INFORMATION AND STAFF COMMENTS
Public Hearing for Robinson
Subdivision Sketch Plan and request
for exemption from full subdivision
review
APPLICANT: William Robinson
SURVEYOR: T.V. Garel
LOCATION: The site is located approximately 4
miles southwest of Rifle on County
Road 321.
SITE DATA: The site is approximately 38 acres
in size.
WATER:
The applicant has a valid domestic
well permit which can serve 3
households.
SEWAGE: The applicant proposes individual
Septic systems
ZONING: A/R/RD
ADJACENT ZONING:
North: A/R/RD
South: A/R/RD
East: A/R/RD
West: A/R/RD
ACCESS: County Roaa 321
I. RELATIONSHIP TO THE COMPREHENSIVE PLAN:
District C - Rural Areas/Minor Environmental Constraints
II. DESCRIPTION OF THE PROPOSAL:
A. Site Description: The site sits on Taughenbaugh Mesa overlooking the
West Rifle area. The property fronts County Road 321. The site consists
of gentle sloping hills with an upward slope to the back of the property.
The parcels adjacent to the site are all large tracts with single family
residences and agricultural uses.
B. Project Description: The applicant proposes to divide 38.04 acres
into 3 lots of approximately 28 acres, 5 acres and 5 acres. The proposal
requests placing the two 5 acre parcels to the front of the property off
County Road 321 and the larger 28 acre parcel to the back of the property
accessing off County Road 321 through a 60' easement between the two 5
acre parcels.
III. MAJOR CONCERNS AND ISSUES:
A. Review Agency Comments:
1. Division of Water Resources: A letter was received from the
Division of Water Resources stating that they saw no problem with
the current well permit serving 3 households. However, they
requested that the well be located on an outlot owned in common
by all property owners using the well. Access to the well and
the right-of-way to be established and maintained for a pipeline
should be provided by easements where necessary. The Division
also noted that the well should be jointly owned by all the lot
owners. In addition, the Division would like to see a lot owners
association which would establish a joint management and
maintenance agreement concerning the well.
See letter, page
2. The Colorado Geological Survey stated that they saw no major
geological problems with the site, however, they recommend that
soil foundation investigations be conducted to determine proper
design for foundations and access roaas.
-5-
• •
B. Staff Comments:
1. The County Environmental Health Officer foresees no problems with
the individual septic systems proposed for the site.
2. Access to the five acre parcels are not noted on the plat.
However, this has been discussed with the applicant who has no
problems with accessing all 3 lots off the proposed 60' access
easement in the center of the property. Each of the driveways
accessing off this easement should be at least 50' from the
County Road right-of-way.
3. That the subdivision, at a minimum, should comply with the Rifle
Fire District requirements. The Garfield County regulations
require a minimum of one 500 gallon cistern per lot for fire
protection.
IV. FINDINGS
1. The sketch plan conforms to Section 4.01, sketch plan requirements of
the Garfield County Subdivision Regulations.
2. The sketch plan conforms to the requirements of the zone district in
which the development is located.
3. That for the above stated and other reasons, the sketch plan appears
to qualify for approval by this Board.
V. PLANNING COMMISSION RECOMMENDATION
On May 11, 1983, the Planning Commission recommended approval to the Boar
of County Commissioners of the Robinson Subdivision Sketch Plan with the
following conditions:
1. The Final Plat shall show access to all driveway easements and
the two 5 acre parcels and that these must all enter off County Road 321
through the one 60' easement and no less than 50' from the county road
right-of-way.
2. The Final Plat shall read "Robinson Subdivision" rather than the
"Robinson Minor Subdivision."
3. The Final Plat shall show the county road right-of-way.
4. A culvert for the barrow ditch to the north of the property where
the access point shall be will be of an approved size according to the
County Road and Bridge Supervisor.
5. Final plat shall show the well within an easement jointly owned by
all three parcels with an access on each parcel to the well.
6. A letter shall be obtained from the Rifle Fire Protection District
stating that the fire protection plan is in compliance with district
requirements, but at a minimum, a 1500 gallon storage tank shall be
located to serve all three lots or three separate 500 gallon storage tanks
shall be provided for each individual lot.
7. The developer shall proceed through the full subdivision review
process.
On May 23, 1983, the Board of County Commissioners tabled the Robinson
Subdivision Sketch Plan and Request for exemption from full subdivision
review so that the applicant would have the opportunity to hold a public
hearing regarding his request.
RICHARD D. LAMM
Governor
310H
•
OFFICE OF THE STATE ENGINEER
DIVISION OF WATER RESOURCES
1313 Sherman Street -Room 818
Denver, Colorado 80203
(303) 866-3581
JERIS A. DANIELSON
State Engineer
MA'/ 21983
April 26, 1983
Ms. Cynthia M. Houben
Garfield County Dept. of Development
2014 Blake Avenue
Glenwood Springs, CO 81601
Re: Robinson Minor Subdivision
NE1/4, SW1/4, Sec. 19, T6S, R93W
Dear Ms. Houben:
We have received the above referenced proposal to subdivide 38 acres into
three lots. The applicants propose to share well number 117935, which was
issued as a domestic well in January 1981. The expiration date was later
extended to January 20, 1984. The well permit has no restrictions prohibiting
the proposed use.
In order to assure that a permanent water supply will be available on an
equitable basis to either lot, we require the following:
1. The well should be located on an outlot owned in common by all pro-
perty owners using the well. Access to the well and the right to
establish and maintain a pipeline shall be provided by easements
where necessary.
2. The well should be jointly owned by the lot owners.
3. Covenants and/or other mechanisms should establish a lot owners
association with powers to make decisions concerning management and
operation of the well. A joint maintenance agreement is a required
part of such an association.
If the above provisions are met, we can recommend approval of this pro-
posal. Please let us know if you have any further questions.
Sincerely,
Hal D. Simpson, P.E.
Assistant State Engineer
HDS/KCK:ma
cc: Lee Enewold, Div. Eng.
Ralph Stallman
Rich Bell
• •
cRifle cEire cProtection Mistrict
Box1133 • Rifle, Colorado • 81650
/C //3
4se--16eett,
'2 A93
o2 / 46-Z
+2,4
/it,
iu
"1 6 1993
RICHARD D. LAMM
GOVERNOR
April 20, 1983
i
411
f co
•
.�'S1�' 1't1�i�� oo
O.
SW
/876%
COLORADO GEOLOGICAL SURVEY
DEPARTMENT OF NATURAL RESOURCES
715 STATE CENTENNIAL BUILDING — 1313 SHERMAN STREET
DENVER, COLORADO 80203 PHONE (303) 866-2611
GA -83-003
GA -83-009
GA -83-010
Ms. Cynthia M. Houben
Garfield County Dept. of Development,,.raX;
2014 Blake Avenue
Glenwood Springs, CO 81601 ,y.
ai
\\
Dear Ms. Houben: 1
RE: ROBINSON SUBDIVISION
ERTEL SUBDIVISION
LAURA LEE SUBDIVISION
We have reviewed the subdivision proposals listed above and find that
there are no major geologic problems which will significantly affect
these minor developments. We do recommend that soils and foundation
investigations be conducted to determine proper design of foundations
and access roads. Additionally, all septic leach fields should be
properly designed for the specific site conditions, and meet State and
County regulations.
If these recommendations are followed, we have no objection to these
minor subdivisions.
Sincerely,
c:SH
Bruce K. Stover
Engineering Geologist
vt
BKS -83-026
GEOLOGY
STORY OF THE PAST ... KEY TO THE FUTURE
JOHN W.ROLD
U!,,ECTOR
GARFIELD COUNTY
DEPARTMENT OF DEVELOPMENT
PLANNING: 945-8212 / ENVIRONMENTAL HEALTH: 945-2339 / BUILDING 945-8241
April 14, 1983
Ms. Cynthia M. Houben, Planner
Department of Development
2014 Blake Avenue
Glenwood Springs, CO 81601
APR 1 4 191,
CG
RE: Letter of Feasibility.for S a e Disposal - Robinson Subdivision Sketch Plan
and request for exemption rom full Subdivlision Review
Dear Cindy:
Based on the information received by this office and past experience with
sewage disposal facilities in the immediate area of the proposed referenced
subdivision, this office has determined and believes on-site disposal fac-
ilities to be both feasible and practical, commensurate with both County
and State regulations, provided proper permits are obtained prior to con-
struction.
It should be further noted that, due to the known conditions, only the
following types of on-site sewage disposal systems would be acceptable,
provided unforseen problems are not encountered:
XX
Approved septic tank and subsurface absorption area
Approved septic tank and sealed dispersal system
Approved septic tank and unsealed dispersal system
System designed by a Colorado Registered Professional
Engineer
Other as specified:
If we can be of any further assistance, please feel free to contact this
office.
2014 BLAKE AVENUE
Very truly yours,
L >
Edward L. Feld
Environmental Health Officer
GLENWOOD SPRINGS, COLORADO 81601
•VT'
•
April 12, 1983
Cynthia M. Houben
Garfield County Department of Development
2014 Blake Avenue
Glenwood Springs, CO 81601
Dear Cynthia:
The City has no comments on the proposed Robinson Subdivision Exemption for the
38 acre parcel. However, I appreciate your notifying us of the proposal.
1k
337 East Avenue P.O. Box 1908
Sincerely,
Brent H. Bean
Planning Director
Phone 625 - 2121 Rifle, Colorado 81650
3--c1114;=LVA-10ME OF "OIL SHALE" U.S.A.