HomeMy WebLinkAboutAs-builts0' 10' 20' Scale: 1" = 20'-0" 1500 -GALLON, TWO-COMPARTMENT, CONCRETE SEPTIC TANK WITH 'ORENCO' PUMPING SYSTEM 4" DIA SDR -35 SEWER LI WITH DOUBLE -SWEEP CL. 0 2 1-- 1. " 1.5" DIA SCH-40 SEWER LINE (MIN 1% DRAIN BA KTOTANK) START RE- AUGNED EL: 61282± DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 01/19/17 3.50' CENTERLINE OF DITCH TO PROPERTY LINE. (typ.) 12' x 44' PRESSURE DOSED, PSD GRAVEL BED ON 3' ASTM C-33 CONCRETE SAND WITH 3 ROWS OF 1.5" DIA SCH-40 PVC LATERALS WITH 5/32" DIA ORIFICES FACING DOWN AT 3' O.C. END EACH LATERAL IN A 90° SWEEPING ELL FACING UP WITH A BALL VALVE IN A VALVE BOX FOR FLUSHING n PROPOSED OWTS v ALL SkRnCI 33 Four Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 carla@allserviceseptic.com Morrissy/Campbell Residence TBD Cedar Street Garfield County, Colorado Project Number. C1257 Date: 10/29/16 Revised: 01/19/17 Designed By: CBO Reviewed By: RHP Drawn By: ANG END RE- ALIGNED. EL: 8125.8't W1.0 Sheet 1 of 3 END EACH LATERAL INA 90° LONG SWEEPING ELL FACING UP WITH A BALL VALVE IN A VALVE BOX ACCESSIBLE AT GRADE SAND FILTER MATERIAL SIEVE %PASSING 100 4 95/100 8 80/100 16 45/85 30 25/60 50 15/60 100 0/4 200 0/2 44' 6 0 O- 3 0 0 STA PLAN VIEW 1' MIN. 1.5" DIA SCH-40 PVC LATERALS WITH 5/32" DIA ORIFICE HOLES FACING DOWN AT 3' O.C. 1' OVER -EX. APPROX. 5' FOR SAND SAND FILTER 1' TOPSOIL s� NATIVE GRADE 12' x 44' PRESSURE DOSED, PIPE AND GRAVEL BED ON 3' ASTM C-33 CONCRETE SAND WITH 3 ROWS OF 1.5" DIA SCH-40 PVC LATERALS WITH 5/32" DIA ORIFICES FACING DOWN AT 3' O.C. 1.5" DIA SCH-40 PUMP LINE (MIN 1% DRAINBACK TO TANK) 1.5" DIA SCH-40 LEVEL MANIFOLD INSPECTION PORT AT EACH CORNER OF EACH BED LANDSCAPE FABRIC ON GRAVEL FLUSHING VALVES INSPECTION PORT AT EACH CORNER �- ti cm 7 741, 12' STA CROSS SECTION GRAVEL FILTER MEDIA ALL Alptt, smoicE 33 Four Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 carla@allserviceseptc.com Morrissy/Campbell Residence TBD Cedar Street Garfield County, Colorado Project Number. C1257 Date: 10/29/16 Revised: 01/19/17 Designed By: CBO Reviewed By: RHP Drawn By: ANG YY2.0 Sheet 2 of 3 DESIGN 4 -BEDROOM RESIDENCE 75 GPD x 2 PERSONS/BEDROOM x 3 BEDROOMS + 75 GAL (4TH BEDROOM) = WASTEWATER FLOW = 525 GPD TANK: 4 BEDROOMS = MIN. 1250 GALLONS + PUMP CAPACITY USE1500-GALLON, TWO-COMPARTMENT SEPTIC TANK WITH PUMP IN 2ND COMPARTMENT SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 1.0 GAU SQ FT CALCULATED STA = Q/LTAR = 525 / 1.0 = 525 SF PRESSURIZED UNLINED SAND FILTER (3' SAND FILTER MATERIAL) = 12' X 44' BED w u_ x 1- a w 0 — 0 — 1 — 2 — 3 — 4 — 5 — 6 — 7 — 8 9 -- 10 SLIP-ON PVC CAP --- DO NOT GLUE INSULATED COPPER - TRACER WIRE 4" DIA SDR -35 SEWER LINE SOIL PROFILE TEST PIT NO. 1 SOIL PROFILE TEST PIT NO. 2 01, 20" TOPSOIL AND ROOT ZONE DEPTH SANDY GRAVEL WITH 1-2' DIA COBBLES (GREATER THAN 50% ROCK) NO GROUNDWATER OR BEDROCK ENCOUNTERED DURING EXCAVATION SOILS LOGS NOT SO SCALE • FINISHED GRADE TO TANK TO HOUSE 0 CLEANOUT DETAIL NOT TO SCALE 20" TOPSOIL AND ROOT ZONE DEPTH SANDY GRAVEL WITH 1-2' DIA COBBLES (GREATER THAN 50% ROCK) LEGEND n loam topsoil sandy gravel SLIP-ON PVC CAP DO NOT GLUE 4" DIA SDR -35 INSPECTION PIPE SPRINKLER VALVE BOX AT GRADE FINISHED GRADE STA FILTER MEDIA 1/4" DIA HOLE DRILLED INTO TWO SIDES OF PIPE FOR VENTILATION (BELOW SLIP ON CAP) INSPECTION PORT DETAIL" HOT T6 SCAS.e. 0 FLUSHING ASSEMBLY DETAIL NOT TO SCALE 10" DIA VALVE BOX WITH SECURED LID 1.5" PVC SLIP X MALE PIPE THREAD ADAPTOR W/CAP 1.5" DIA BALL VALVE 1.5" DIA PVC LONG SWEEP 90° BEND GRAVEL AiLk lVIG 33 Four Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 carla@allserviceseptic.com Morrissy/Campbell Residence TBD Cedar Street Garfield County, Colorado Project Number: C1257 Date: 10/29/16 Revised: 01/19/17 Designed By: CBO Reviewed By: RHP Drawn By: ANG W3.0 Sheet 3 of 3