Loading...
HomeMy WebLinkAboutInsulation Cardfro u bNikieoliA rtipai i + ABOVE This form must be filled out and posted to comply with building code and FTC requirements. i»eets flRC Section h\!1101.4 requirements. Pease post near electrical panel. PLEASE ATTACH PR®: 1 UCT TECHNICAL IATA SHEET BEFORE E POSTING The following spray polyurethane foam insulation system(s) has been installed. Consult International Building Code, Section 2603 Foam Plastic Insulation, International Residential Code (IRC) R314 Foam Plastics, or International Energy Conservation Code (!ECC) Section 102 for specific requirements, it BASF Corrporritkm Product(s) histalled: Enertite Nominal 0.5 pcf Density (Open -cell Spray Polyurethane Foam) Spraytite 178 Series 2.0 pcf Density (Closed -cell Spray Polyurethane Foam) Spraytite 158 Series 2.0 pcf Density (Closed -cell Spray Polyurethane Foam) This spray polyurethane foam insulation system has been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of... (see fZ-value chart on reverse) Area Insulated R -Value Thickness* Attic Area R— @ inches Sloped Ceilings ikNOL VZI R— r-5 6_, 0 inches Walls (Where: R_Val ) R— 13.2 @ inches Walls (Where: ) R— @ inches Floors (over an unheated crawl space) R— @ inches Crawl Space Perimeter . R— @ inches Basement Interior Walls R— 0 inches Other (Where: ) R— @ inches *Nominal thicknesses are representative of a field, spray -applied foam material. List the code -required fire protection product(s) installed (List alternative materials or assemblies approved by 3rd party or ICC -ESR): 15 -minute Thermal Barrier: ❑ To Be Covered with 1/2" Gypsum OR Limited Access (No Storage) Ignition Barrier: Jobsite Location: Building Contractor: insulation Contractor: Loos[il[ P..) 1 Mcwkaices, �ccu►rc�ke. sof\ Installed By: 11111b Caution— No Hot Work - ' i rethane foam is combustible and should be treated as such. No welding Date Installed: Z -2Z' _ Phone: c0Q) 2't —T61 BASF Corporation 1703 CrosspointAvenue Houston, TX 77054 Tel: 800-796-9743 www.spf.basf.com or cutting unless foam has been protected from accidental ignition by open flame, OGSCIJLQTKDIMC°Y ®Xr0'REMOVE PoOy re the e c‘e ScHutio s nazuLavuom ©Liam) Enertite NM 1/2# Open -cell OC SPF (inch) Total R -value* U -factor* 3' 11 0.091 3.5" 13 0.077 4" 15 0.066 5' 19 0.053 I 5.5° 21 0.048 6" 22 0.045 7.5" 28 0.036 8" 30 0.033 9.5" 35 0.029 10" 37 0.027 11.5" 43 0.023 12" 45 0.022 13" 48 0.021 14" 52 0.019 15" 55.5 0.018 16" 59 0.017 DO MOT RIEbillOV/TE h,s to li ed R vaDue Charts Spraytite178 Series Closed -cell CC SPF (inch) Total R -value* U -factor** 1" 6.7 0.149 1.5" 10 0.100 2" 13.4 0.075 2.5" 16.8 0.056 3" 20.1 0.050 3.5" 24.2 0.041 4' 27.6 0.036 4.5' 31.1 0.032 5" 34.5 0.029 5.5" 38 0.02.6 6" 41.4 0.024 7" 48.3 0.021 8" 55.2 0.018 9° 62.1 0.016 10" 69.1 0.014 11" 76 0.013 Spraytite158 Series Closed -cell CC SPF (inch) Total R -value - I U -factor** 1" 6.6 0.152 1.5" 9.9 0.101 2" 13 0.077 2.5" 16.3 0.061 3" 20 0.050 3.5" 24 0.042 4' 27 0.037 4.5" 30.4 0.033 5" 34 0.029 5.5" 37.4 0.027 6" 41 0.024 7° 48 0.021 8" 54 0.019 9" 60.8 0.016 10" 68 0.015 11" 75 ! 0.013 *What You Should Know About R -values These chart shows the R -value of this insulation. R means resistance to heat flow. The higher the R -value, the greater the insulating power. Com- pare insulation R -values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R -value, it is essential that this insulation be installed properly. **U -factor is the inverse of R -value as represented in BTU /(h °F ft2). The lower the number, the better the performance of the material or assem- bly. Using U -factor requires SPF is used within an Opaque Assembly. If used in a rafter assembly in a sealed attic approach, the SPF must be wrapped around all framing to ensure continuity. BASF Corporation 1703 Crosspoint Avenue Houston, TX 77054 Tel: 800-796-9743 www.spf.basf.com ISO 9001:2000 Accredited Facility - Houston, TX IMS U ILGGR1TICD !f' CARD o DO :O j P®0yurethane August 2013