Loading...
HomeMy WebLinkAboutApplication- PermitJob Address No. 6526 GAR LD Lviwi BUILDING, SANITATION and PLANMNG DEPARTMENT 109 Sth Street Suite 303 Glenwood Springs, Colorado 8I601 (303) 945-8212 4408 County Road 331, Silt AiaturcofWork Building Permit Use of Building Addition & Garage Owner Douglas Weller Contractor Owner Amount of Permit S 1,412.40 Permit: 856.00 Plan : 556.40 Paid $454.84 10-9-97 October 28, 1997 Date S. Archuleta Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only. PERMIT NO. 6S ~✓ PARCEL/SCHED NO. Joe AonREss 440 8 1 O w),L1.4 'Lad 33 / L51 1 iL, CD F/ b .9- 1 LEGAL DESCR. ANO. (� r BLOCK /� f r I/ Q'"/)2I.'E"�2--1- SUBDIVISION I EL.,1 E' ST�4TE 5 2 OWNER �00(.-E51Q.S (.1. :1 f {{[GL[l E - ADDRESS 1/276 g L',1�_ 33 f S / I A. C' d PHP76- aS1i4 WK PH 8'76 •9999 3 CONTRACTOR (5071 Pi ADDRESS PH. LICENSE NO. 4 , ARCHITECT OR DESIGNER Sam ./2_,./ ADDRESS PH. LICENSE NO. 5 ENGINEER ADDRESS PH. LICENSE NO. S.F OF BUILDING alk W r] Ar 7'. Gn - i6 6 $3p, 3" G'uo' .F OF LOT - HEIGHT NO. OF FLOORS „Z.6 7 USE OF BUILDING ,9. Aga/ LU, -1 /¢/L4G6 8 CLASS oFWORK: ❑NEEhW ADDITION DALTERATION Er REPAIR nMOVE nnREMOVE 9 DEscnoe woa: �7 111/TiDN DF 02 C5'/ tiL/i',L. L/Umiti/.��-,b2,4.Fj6 /-/e&r4- Td E,Aii%/i1%(' tterzi,c&- 10 . GARAGE SINGLE \ DOUBLE CARPORT SINGLE DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 1-'', 11 VALUATION or wonK: $ ADJUSTED VAY.$9� J 70 .e � PERMIT FEE % . r Q PLAN CHECK FE SPECIAL CONDITIONS: r s r` ` 51i 6F3,1 - s�'X /7.4/? /4 —Jra�j "w' 45 - . SCHOOL IMPACT FEE NO. OF BUILDINGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL ppIS '/ /f,9 TOTAL FEE /LA?, I , Vo OCC. GR. CONST. TYPE SEPARATE PERMITS VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NOT COMMENCED WITHIN OR ABANDONED FOR COMMENCED. I HEREBY CERTIFY THAT THE SAME TO BE TRUE GOVERNING THIS TYPE HEREIN OR NOT. THE AUTHORITY TO VIOLATE LOCAL LAW REGULATING CONSTRUCTION. / NOTICE ARE REQUIRED FOR ELECTRICAL PLUMBING, NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED A PERIOD OF 180 DAYS AT ANY TIME AFTER I HAVE READ AND EXAMINED THIS APPLICATION AND AND CORRECT. ALL PROVISIONS OE LAWS AND ORDINANCES OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED GRANTING OF A PERMIT DOES NOT PRESUME OR CANCEL THE PROVISIONS OF ANY OTHER STATE CONSTRUCTION OR THE PERFORMANCE (Dake) WATER SUPPLY / �T ���yyy DATE PERMIT ISSUED / 0 - ,Wp HEATING, SPECIAL APPROVALS REQUIRED RECEIVED NOT REOUIRE❑ IS ZONING WORK IS HEALTH DEPT KNOW FIRE DEPT. TO GIVE SOIL REPORT OR OF SETBACKS FLOOD HAZARD Signa a orOH' , Con ,,------_ �: :.— — factor or authorized agenic n. read an• und-rsttood notice :6ov=. I7 / / I�/ ��A' 6 - MANUF. HOME uildi . Department Appr• : ".ate / Planning Dep. rtmentApproval/date OTHER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION, THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND 1N SUPPORT OF THE OWNERS INTEREST. Garform,003 1 HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL I ) �S� /f /or 9— 97 GARFIELD COUNTY Building and Planning Douglas Weller Oct.16,1997 4408 County Road 331 Dear Doug Your Drawings are not acceptable for you to obtain`a Building Permit. We do not do the Engineering,, your drawings must show the size, length, brand, solid, or manufactured, of floor joists and spacing. There is no indication of any center support, if there is , you must have it engineerined to 400 load, ✓ You. must show an Occupancy sepraration wall and eif`closing sbid doorbetween the Garage and stair way. k /You must show a section through, showing the joists, required insutation,wiith the garage side lined with 5/8" fire code sheet rock with at least one coat of tape, You must have a detail of the stairs showing the rise, tread, landings,handrails, guardrails, min. headroom etc. No 7 -Is the office to be created? if so show partitions and measurements 71 need the drawing to show the room arrangement of the area next to where the Garage will Attach, showing windows, doors, size and location. When you get this material to me, we will continue with your Application. ''*All must be on larger paper and to 1/4" scale. Don Owens Chief Building Official Garfield County 109 8th Street, Suite 303 945-8212/285-7972 . Glenwood Springs, Colorado . 81601 • GARFIELD COUNTY Building and Planning Douglas Weiler Oct.16,1997 4408 County Road 331 Dear.Doug Your Drawings are not acceptable for you to obtain a Building Permit. We do not do the Engineering, your drawings must show the size, length, brand, solid, or manufactured, of floor joists, and spacing. There is no indication of any center support, if there is , you must have it engineerined to 40 4 load. You must show an occupancy separation wall and self closing solid door between the Garage and stair way. You must show a section through, showing the joists, required insulation,with the garage side lined with 5/8" fire code sheet rock with at least one coat of tape. You roust have a detail of the stairs showing the rise, tread, landings,handrails, guardrails, min. headroom etc_ Is the office to be created? if so show partitions and measurements. I need the drawing to show the room arrangement of the area next to where the Garage will Attach, showing windows; doors, size and location. When you get this material to me, we will continue with your Application. All must be on larger paper and to 1/4" scale. G,11 Don Owens Chief Building Official Garfield County 109 8th Street, Suite 303 945-8212/285-7972 Glenwood Springs, Colorado 81601 The following items are required by GarfieldCounty for a final inspection: I. A final Electrical Inspection from the Colorado State Electrical Inspector. ?. Permanent address assigned by the Garfield County Building Department posted where readily visible from access road. 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing, 4. A complete bathroom, with wash bowl, tub or shower, toilet stool, hot & cold running, water, floors and walls finished an a privacy door. 5. All steps outside or inside over three (3) steps must have handrails, guardrails on balconies or decks over 30" high constructed to all 1994 UBC requirements. 6. Outside grading done to where water will detour away from the building. 7 Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e., weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CER'I'IF'ICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL IRE ABOVE ITEMS HAVE BEEN COMPLETED. ****CANNOT OCCUPY OR USE DWELLING UNTIL A CERTIFICATE, OF OCCUPANCY (C.O.) IS ISSUED. OCCUPANCY OR USE OF DWELLING WITHOUT A C.O. WILL BE CONSIDERED AN ILLEGAL OCCUPANCY AND MAY BE GROUNDS FOR VACATING PREMISES UNTIL ABOVE CONDITIONS ARE MET. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # Signa prmtcond.lst Date GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are require to indicate appropriately and to submit the completed check list at time of application for a permit. For the placement of a manufactured home, questions numbers 1-4 and 19-28 are the only questions that need to be addressed: 1 1. Is a site plan included that indicates the distances of the proposed building or addition to property lines, other uildings, set back easements and utility easements? Yes 2. Does the site plan include the location of the I. S.D. S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties), streams or water courses? Yes �r 1, 3�����4 1. !,.i-: .' :f i ., c.. 3 . Does the site plan indicate the location and direction of the County or private road accessing the property? Yes 1/' 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel m acc rdance with the uniform building code or per stamped engineered design? Yes 5 f ),)i ; ;' 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes (1 6. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes °' 7. Do the plans include design loads as required under the Uniform Building Code for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County), floor loads and wind loads? Yes 8. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 10, Does the building section drawing or other detail include the method of positive connection of all columns d beams? Yes 2 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade con urs? Yes . / 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes i1 CA. No 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes i/ No 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes / No 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes � ,, No 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes Irl fC . No 18. Do you understand that if you are building on a parcel of land created by the exemption process or the sub 'vision process, are building plans in compliance with all plat notes and/or covenants? Yes No 19. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission from the association, if required by that association, prior to submitting an application for a building permit? If you do not have written permission from the association, do you understand that the plan check fee will not be refunded should the architectural committee deny or reject your building plans? Yes i`.' ../ No 20, Will this by the only residential structure on the parcel? Yes V No If no -Explain: 3 21. Have two ( ) complete sets of construction drawings been submitted with the application? Yes 1/ 22. Is this an application for the placement of a manufactured home? Yes No V If yes, have you specified the size of the unit (min. 20ft. x 20 ft); live roof load (min. 40#); wind design min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring? Yes i(L) 23. Have you designed or had this plan designed while considering building and other construction code requirements? Yes - No 24. Does the plan accurately indicate what you intend to constauct and what will receive a final inspection y the Garfield County Building Department? Yes No 25. Do you understand that approval for design and/or construction changes are required prior to the application of these changes? Yes ►// No 26. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School Impact" ar Septic System" fees required, at the time you pick up your building permit? Yes V r No 27. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before. Failure to give twenty four (24) hour notice for inspections will delay your inspection one (1) day? Yes V No 28. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes ,f% No 29. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project complying with the Uniform Building Code? Yes G , No 4 I hereby acknowledge that I have read, understand and answered these questions to the best of my ability. signature -1. date Phone: g - 9ei (days); 3'% o 4tq (evenings) Project Name: (/ )QJ e.f A ct r Project Address: Liz -to Co £oo ) ) Po k1%l- Notes: If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays m issuing the permit are to be expected.. Work may not proceed without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes; the application may be placed behind more recedt applications for building permits in the review process and not reviewed until required information has been provided and '}he apilication rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. Ii=ierApp02.95 Effective August 15, 1995 5 No. 6,s Job Address Z/101' Owner Gf d. .� Contractor Assessor's Parcel No Date /d er-9/ BUILDING PERMIT CARD Address )a8 -1 -?,?-e---• Phone #876,---785/9 Address RH dINSPECTIONS Solis Test Footing Foundation Grout Underground Plumbing Rough Plumbing Framing ,- 1 6 Insulation 4 -- 9 "✓ Roofing Drywall 1/1 Gas Piping ---/A ; y—g' 0'3 7 — NOTES ..57-)44 au -yummy clfA fin Kekeit,00 24-c° Setbacks: Front Rear Phone # LH Zoning Q./a& 42ed /2-705 Weatherproofing Mechanical Electrical Rough Electrical Final tate Finalfeh lJf�/J y (State) q-3-qpe4q ,`/Y7� ecklist Completed'? 'r Certificate Occupancy # Date Septic System # Date Final Other (continue on back) Date: /1- /7-i To: fit I. �, 2331 .al- , C NbC2- Ga�fietd County BUDDING & PLANNING DEPARTMENT Code Compliance Oce shaackett Dear Permit Holder, Please refer to your building permit number 63-6, , issued /D _2S- cp A routine review of our o en building permits indicates that we have not received a request for an inspection on this permit since X- 03 Please be advised that building permits expire, per Uniform Building Code, section 106.4.4. "Every permit issued by the building official under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at arty time after the work has commenced for a period of 180 days. Before such work can be recommenced, a new permit shall first be obtained to do sq, and the fee therefore shall be one half the amount required for a new permit for such work, provided no changes have been made or will be made in the original plans and specifications for such work, and provided further that such suspension or abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall pay a new full permit fee." Please contact this office at your very earliest convenience, in writing, to advise us about the status of your permitted work. If you have not responded within thirty days from the receipt of this notice the permit will be closed and a permanent notation will be placed in the property records at the County Assessors office that indicates that the work permitted was not inspected, is not approved and that the building or area may not be legally occupied. Thank you for your cooperation. Sincerely, Tim 9foffzday Dave weal Building Inspectors /00-(1 108 8th Street, Suite 201, Gleravood Springs, Colorado 81601 Ms. Judy Weller 4408 CR 331 Silt, CO 81652 Re: Our conversation on the morning of 3-20-03 Dear Judy, After our conversation this morning I spoke with the Chief Building Official, Andy Schwaller. He has asked me to give you a written explanation of what you need to do to finalize this old building permit. You will see in the enclosed letter that the permit has expired. We will not charge a renewal fee if you will make every attempt to finish within 30 days. There are three items we need you to take care of to finalize the permit; //. Either finish the siding or paint the exposed OSB wafer board "2' Remove the galvanized pipe from the gas piping system and replace it with approved pipe. We will also need you to call us for a pressure test on the piping after it is fixed. X Finish connecting the boiler. Your attention to this matter is greatly appreciated and if you have questions please call me at 945-8212. Sincerely, David Mead Building Inspector