Loading...
HomeMy WebLinkAboutApplication- PermitNo, 6500 GA.RFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 (303) 945-8212 Job Address 9950 County Road 215, Parachute Nature oFWork Building Permit Use of Building Compressor Building (Bldg. ##4 Owner Barrett Resources Contractor Ford Construction Co. Amount of Pek,.iit S 606.79 Permit Fee: $367.75 Plan Check: $239.04 Date 10/8%97 L. Campbell Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO M1 Applicant to complete numbered spaces only. PERMIT NO. PARCEIJSCHED NO. `to y y o Irmo BLAB Jon A.oaREas 1 ' LEGAL DESCR. LOT NO. BLOCK SUBDIVISION (c ee a fe) 2 OWNERrftitRe5ciatie r 12.0 1.4 R.44.1Ireoa ADDRESS �u�4ZZt0 TIJ 'q WKP N, 3 CONTRACTOR Vt)(6, CenSkiVaricoil Co 1ty A r es4 R 1 ADORESS G,. 4 O g 1d0S pH.245 -13L13 LICENSE NO. 4 ARCHITECT OR DESIGNER ADDRESS PH. LICENSE NO. 5 ENGINEER ADDRESS PH. LICENSE NO. 6 S.F OF BUILDING 1 1 1000 b tik S.F OF LOT HEIGHT NO. OF FLOORS 7 USE OF BUILDING 8 CLASS OF WORK n NEW/ADDITION o ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 9 DESCRIBE WORK: V f*e zxt' A 1el-` 10 GARAGE SINGLE DOUBLE CARPORT S{NGLE DOUBLE . DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 11 VALUATION OF WORK: S 21073b7 f ADJUSTED VALS.6 7g yi 6 PLAN CHECK FEE/ 23 7• 0l PERMIT FEE/..j 4 7, .._ SPEC:AL CONDITIONS: /q16, / / �j / /ADV / {, 71/ �hiiS Y 7$ iir''d SCHOOL IMPACT FEB NO. OF BUILDINGS CN PARCEL USE CF BUILDINGS NOW ON PARCEL �4 TOTAL FE_4120 0 6., 77 OCC. GR. S / CONST. TYPE i Al f NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBTNG, VENTILATING OR AIR CONDITICNING. THIS PERMIT 3ECCMES NULL AND VCID IF WCRK CR CCNSTRUCT1CN AUTHORIZED NOT CDMMENCED WITHIN 180 DAYS. OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER COhaENCEC I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS ,APPLICATION AND THE SAME TO BE TRUE AND CORRECT ALL PROVISICNS OF LAWS ANO ORDINANCES C.VERNING THS TYPE OF WCRK WILL EE COMPLIED WITH WHETHER SPECIFIED HERE'N CR NOT THE GRANTING OF A PERMIT COES NOT PRESUME AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE LOCAL LAW GULAG—NE C TRUCTION CR THE PERFORMANCE CON CT11'/ 6 I _ J6,�: {Dates l Q 97 WATER SUPPLY DATE PERMIT ISSUED HEATING, SPEC -AL APPROVALS REcuIREO RECENE6 NOT RECUIREO IS ZONING WORK I5 HEALTH DEPT. KNOW FIRE DEPT TO GIVE OR OF SOIL REPORT SETBACKS FLOOD HAZARD ! 1 Slgnawre or � _ CanhaC:or ora ar7Xed agent .� ng roadn • uni rstood nonce . • •v-. 4 • 107:702 �/i iil�:— 1 MANUF HOME Liming ›cartment Aoorovsklate PlannlrgDep. rtment Approval/date / 8 OTHER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TC AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE CF -HE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING CFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA CR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES CR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE ;INITIAL The following items are required by Garfield County for a final inspection: I. A final Electrical Inspection from the Colorado State Electrical Inspector; 2. Permanent address assigned by Garfield County Building Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, with wash bowl, tub or shower, toilet stool, hot and cold running water, . floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1994 UBC requirements; 6. Outside grading done to where water will detour away from the building; 7. Exceptions to the outside steps, decks and grading may be made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made. A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED, ***"Cannot occupy or use dwelling until a Certificate of Occupancy (C.O.) is issued. Occupancy or use of dwelling, without a C.O. will be considered an illegal occupancy and may be grounds for vacating premises until above conditions are met. I understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit 4 Signature Date SES lC-97 TUE 14:55 FORD CONSTRUCTION FAX Na U(U245buau September 15, 1997 FORD CONSTRUCTION COMPANY, INC. Garfield County Planning & Zoning Mr, Steve Hackett 109 8th Street, Suite 303 Glenwood Springs, CO 81601 RE: Barrell Compressor Buildings Mr, Hackett: The Owner has instructed Ford Construction Coj ; Inc. to low rhthe to e height which sfrom hould epd posed 25' to 24' eave height. This will reduce the averageg within the guidelines of 25' or lower, If you have any questions or if I can be of further assistance, please feel free to call me at (970) 245-9343, Thank you, 7 g—c3'Y2t/Kelly d President cc: Brad Moss, Barrett Resources 714 Arrowest Ret., Ste. A • Grand junction, CO 81505 • (970) 245-9343 • FAX: (970) 245-5090 Barrett Resources Building "C" (30 x 40) LEGAL DESCRIPTION: SECTION 29 T6S R94W (1000' FROM EAST LINE AND 1000' FROM NORTH LINE) AT THE INTERSECTION OF HIGHWAY 6 AND ANVIL POINTS ROAD a;Pb 3 GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for CONSTRUCTION OF COMMERCIAL OR MULTI -FAMILY RESIDENTIAL BUILDINGS including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order W determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. 1 Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes _$. No ,u Not necessary for this project 12) 2. Are the plans submitted for application construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only", "Approval drawings only", "For permiI issuance only" or similar language? Yes _'__ No (1, Not necessary for this project (2) 3. Does the site plan include the location, including the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses of the I.S.D.S. (Individual Sewage Disposal System) and has the system been designed, stamped and signed by a Colorado registered engineer? Yes No to Not necessary for this project __4_(2) 4. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes _Y___ No (o Not necessary for this project (2) 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes _ _ No 0) Not necessary for this project (2) 6. If the building is a pre-engineered structure, is there a stamped, signed engine red foundation plan for this.building? Yes No to Not necessary for this project f2, 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No (1) Not necessary for this project __`/%_-__(2) 8. Do the plans indicate the size an location of ventilation openings for the attic, roof joist spaces and soffits? Yes No (1) Not necessary for this project (2) 2 9. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per square foot in Garfield County)? Yes _/c__ No (() Not necessary for this project (2) 10. Do the plans include design loads as required for floor loads under Uniform Building Code Section 2304 and Tables 23-A and 23-B? Yes No (1) Not necessary for this project _X__(2) Gravel pc Cloockrzi 11. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes _X__ No („ Not necessary for this project (2) 12. Is the wind speed and exposure design included in the plan? Yes No (1) Not necessary for this project (2) 13. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes __ No u, Not necessary for this project (2) 14. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes _4.__ No 0, Not necessary for this project (Z) 15. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes __X_ No (1) Not necessary for this project (2) 16. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No (u Not necessary for this project (2) 17. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No _(,) Not necessary for this project (2) 18. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes No (i) Not necessary for this project _ __(z, 19. Does the plan include a window schedule or other verification that 3 windows provide natural light and ventilation for all habitable rooms? Yes No w Not necessary for this project __X._[2) 20. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No t„ Not necessary for this project cz, 21. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes No «, Not necessary for this project ___(2) 22. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5-A) Yes X No (l) Not necessary for this project (2) 23. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes No („ Not necessary for this. project ' t2, 24. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No si, Not necessary for this project 25. Do the plans indicate the location and dimension of restroom facilities and if more that four employees and both sexes are employed, facilities for both sexes? Yes No ciE Not necessary for this project iz, 26. Do the plans indicate that restroorns and access to the building are handicapped accessible? Yes No fl, Not necessary for this project _ X_cz, 27. Have two (2) complete sets of constructions drawings been submitted with the application? Yes __4_ No nl Not necessary for this project 12, 28. Have you designed or had this plan designed while considering building and other construction code requirements? Yes __ No (3) 29. Does the plan accurately indicate what you intend to construct and 4 what will receive a final inspection by the Garfield County Building Department? Yes _;I__ No (3) 30. Do you understand that approval for design and/or construction change`,s are required prior to the implementation of these changes? Yes i No (3) 31. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "Septic system " fees requi ed, at the time you pick up your building permit? Yes __X_ No (3) 32. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes _ _ No (3) 33. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the projectcomplying with the Uniform Codes". Yes No (3) 1 hereby acknowledge that 1 have read, understand and answered these questions accurately to the best of my ability. sign Lure qJ 91c - date Phone: 2(454 3L-1.1 (days); (evenings) Project Name: pre -t+ Coes- Project Address: OF HAWN (4, PoiNTS Qt (Refer to notes on next page) 5 Notes: (1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. (3) If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. PerApp01.94 Effective - January 1, 1995 6 8759 x 7a. z:060?, ^�^ Oltlts, t4' rLv`,1 ter!, C r t, -N 1 .i 7 l .40 .1," 514t-deT; RES.E ,„• 2C - R 5/5 BM 51.63 ,d:lU`r5o 5207 • 52 o /: 0 L O R w ? -> -- L - - f ) — o h r ---.___,,-,-r- ----- J F HOLMS �. r • 54 MEC ii A r !fr_ 5594' . �S ha.r r a r 5520 5570 �II - FSO 7 1 _ `. 1 has s ti I °378 za-- y y3 J � 8 L.� Lacy, i p rave 'it non. _ p&RGW - . co 4°' 5565 -,nn 4oca/ect ;h pec. �9 7-‘5 -R 91(41) (loco' El. ie cot- :kniersee./1:0Pk of /1 44/.0,1 6 oft- Anti: n os Roow 4377000mA, °375 '5,Ye ?arrelT aoiipressoh f (od 3(c) INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECT"IONS BUILDING PERMIT GARFIELD COUNTY, COLORADO Date Issued/ ' ..Zoned Area Permit No. ..�.. �ir� AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and const n of the above described structure, the permit may then be revoked by notice f my Building Insp. +r and IMMEDIATEL I ECOME NULL AND VOID�� Use 1j �;.- .:. if 0.2'. o 1/ II f 1.nr Aar £t, t lk . Address oAifiligira egal Description Setbacks Front Side Side Rear This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. INSPECTION RECORD Footing / I — 13 `771 ,-�-t(1.3)A n: ) r Z -', _ ° v-7 -7..,:_c, , _4....._..7._ i ". Foundation 1; -11f - 5 7 .rr] X Underground Plumbing Insulation Rough Plumbing Drywall Chimney & Vent Electric Final (by State Inspector)c *Ifi' Gas Piping Final c.S yee e"3 Electric Rough (By State Inspector) Septic Final Framing (To include Roof in place and Windows and Doors installed). Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. A P P R O V E D DO NOT DESTROY THIS CARD Date /'Ft47 By/1/7 IF PLACED OUTSIDE - OVER WITH CLEAR PLASTIC