HomeMy WebLinkAboutApplication- PermitGARFIELD COUNTY
BUILDING, SANITATION and PLANNING DEPARTMENT
109 eth Street Suite 303
Glenwood Springs, Colorado 81601
(303) 945-8212
Job Address 0269 Willow Lane, Carbondale
Nature of Work Building Permit
Use of Building Completion of Existing Foundation of Garage/Storage
Owner _ Dan & Marian Hughes -
Contractor Owner
Amount of Permit: $
White-Treas.
Canary -Office
ink -Applicant
Id- Duplicate
207.90
Permit: 126.00
Plan : 31.90
August 26,'1992
Date -
S. Archuleta
die
GARFIELD COUNTY
APPLICATION FOR BUILDING PERMIT
r please
Assessor s Parcel #Z3F3 ���r_ c'o 044
TO BE FILLED OUT BY APPLICANT
ADDRESS Q,2¢4 r,.//cLOrd 69-A1E
SUBDIVISION %A:Lc k sli ci , aha 4 s
FILING # LOT BLOCK `
TAX SCHEDULE #
print
or
type
PERMIT NUMBER 0--4.
DATE . g-- / e 9TH,
LEGAL (SEC/TWN/RNG)
NAME L ,4n/ $4- ,fl, / f /iJ .1 -744..6 -NES
MAILING ADDRESS a24,1F! W/44044) 441iJf
CITY C:. • •A,r2,.24Ct PHONE 9
124
W
NAME
ADDRESS
CITY
CONTRACTOR
NAME
ADDRESS
CITY
PHONE LICENSE #
CLASS OF WORK
NEW ALTERATION ADDITION
DEMOLISH REPAIR MOVE
MOBILE HOME (make/model)
S.F. OF BUILDING?3 x i. 7"S . F . OF LOT ;tom A44,1_4
FLOORS f HEIGHT /,a'
OF FAMILY UNITS / # OF BEDROOMS
INTENDED USE OF BUILDING .570RAdip.
GARAGE: SINGLE 40?‹.3 CARPORT: SINGLE DBL
FIREPLACE
WATER SUPPLY
DRIVEWAY PERMIT
SITE PLAN
BUILDING PLANS
DOCUMENTS ATTACHED
SANITARY SEWER CLEARANCE /Cr
ON SITE SEWAGE DISPOSAL PERMIT �-L X i rr-t q
OTHER DOCUMENTS (specify)
PLOT PLAN
NOTE: Show easements, property line dimensions,
all other structures, specify north, and street
name. For odd shaped lots, or i± space is
too small, provide separate plot plan.
# OF BUILDINGS NOW ON PARCEL
USE OF BUTLD NGS NOW ON PARCEL
re �� ems �� (Q /s () I'xts j)
�.� / i'c�
(ire erl%ovs e_ - 0)0 u N. aoki t,
► rl I? gS a-7' 71-r e_ use w )
Ira:// 1 1r(4_5, h e.s . /6e
i5 r(,) cc, nftle 77e_ 4u/*tor/ q q
6i 'R `/ e /�/o �-cc. 6] �.) ctn."' cines-//
ore .e. (2-0 z-8) GL/ C 1 /4-/
cogs- ort ,a(Q16 (Qn 710 L�
G`'eet/4'014c ee)/T-, `c.7 e.,
FRONT PROPERTY LINE
STREET NAME/ROAD NUMBER
CHECK IF CORNER LOT
DESCRIPTION OF RK PANIED
L S ! 7G y�CI
2- a r fi?
I herebyc owledge tleat I have read this
application and the above is correct and I
agree to comply with all county ordinances
and state laws regulating building construction
SIGNATURE
VALUATION C7R he e � � p o FOR OFFICE USE ONLY
PERMIT PEE $ f� 4,420 PLAN'CHECK FEE $
TOTAL FEE $207,410 SCHOOL IMPACT FEE $ NA -
DATE
-DATE PERMIT ISSUED
FLOOD HAZARD
ZONING DISTRICT
TYPE OF OCCUPANCY
TYPE OF CONSTRUCTION V— AI y
S.F. OF BUILDING 3 Q/ 6' S.F. OF LOT e a Cr
MAX. HEIGHT ROAD CLASS. ---
SETBACKS FROM PROPER INE: FRONT
REAR RIGHT LEFT
OFF STREET PARKING SPACES REQUIRED
CERTIFIED BLDG ELEVATION
SPECIAL CONDITIONS
PROBLEMS WITH PERMIT
ADDITIONAL INFORMATION NEEDED
CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
OR ENGINEER
./
B LDING DEPA'TMENT
PUNNING DEPARTMENT DATE
‘ixlec-7
C0
rirfrct
7/ C-5(•
fl°
0 .c3
7/4
('Vi ,r•1
v'‘ela e-
tV Was /4
/7Le
.. •
PI'nt4lT 1 OWNER. 1 I 1 r Ci `-i Ilt .S LOCATION (22 ( •: ;I, -- ale
CotITRACTOlt
THE FOLLOWING ITEMS HAY 11AVE BEEN OMITTED FROM YOUR 1'I MIS on MAY NOT COMPLY WITH
THE PROVISIONS OF TUE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS
BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1900 EDITIONS OF TUE CODES.
THESE ITEMS ARE ItEQUIRI;MEN'!'S FOR R-3 OCCUPANCIES ONLY (ONE AND TWO FAMILY
DWELLINGS) AND ARE NOT ALL INCLUSIVE OF TILE CODE REQUIREMENTS, PUT ARE MEANT AS
A GUIIIE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE
REQUIREMENTS. THE APPROVED PLANS RETURNED TO YOU SHALL DE KEPT AT TIIE BUILDING
SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF TBE NATIONAL ELECTRICAL CODE
CONTACT THE COLORADO ELECTRICAL. INSPECTOR.
THERE SHALL DE A FINAL. INSPECTION AND APPROVAL OF ALL, BUILDINGS AND STRUCTURES e
mum C HPL Tru AUD READY FOl OCVUrA CY U U — UBC SEC. 305 (0).iodn �,�,� lei,
f ierree.0 f!4U14'1W(y(awe i e�lp i( �vitelr..(r.7 )cirf� psi
1. nc0 de for- foUU ndha tet 26. load
Mortarbearing
grout shallrequired
in accordann ce0with
in 28 days - UDC C p
UDC Chapter 24 & Table 24-A and 24-0.
2 Masonry units, mortar, and grout shall be protected during cold weather in
accordance with UBC Sec. 2404 (c). Concrete shall be protected during cold
or hot weather in accordance with URC Sec. 2605 (f) and (g).
3. Minimum concrete and/or masonry foundation reinforcement requirements are
shown on the attachment. (Notes these minimums apply only if a foundation
soils investigation is not performed and the soils are assumed to have an
expansion index of 20 or less and footing loads Less than 2000 lbs/linear
foot - UDC Sec. 2904 (a) and (b) and Sec. 2906.
4. Foundation frost protection in 30" from finished grade to top of footing -
UBC90UBC Il21t1 d(a) -
1ons shallextend a min. of 6" above finished grade - UBC 2907).
Provide for the control and drainage of surface water away from the buildingg
- UDC 2907 (f).
7. Foundation walls enclosing a basement below grade shall be damp -proofed on
J
the exterior with approved materials UDC Sec. 1707 (d).
0 Foundation plates or sills shall he redwood or pressure treated wood (UDC -
2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia
bltme or
6ofeetPapart.� min. of 2t 7" ito boltsnpercpiecetand withinr12" of eachespaced not e
than
end of piece
- UDC 2907 (1).
9. Exterior concrete or masonry piers shall extend 0" min. above grade unless
the posts or columna which they Rapport r e treated or decay resistant wood.
Columns and posts located in basements shall be supported by concrete piers
or metal pedestals extending 6" min. above earth and 1" min. above floor
� unless treated or decay resistant wood - UDC Sec. 2516 (c) 4.
(TOManufactured trusses, and manufactured joists and beams (i.e. T.11/Micro-
Lams, BCI/Versa-rams, Glu -Lams, etc.), shall be shred and installed in
accordance with the manufacturers requirements.
11. Wood joists or floor beams located closer than 10" or wood girders closer
than 12" to the ground in crawl spaces shall he treated or decay resistant
wood - UDC Sec. 2516 (c) 2.
12. Girders supported by masonry or concrete shall have 1/2" air space at top,
sides, and ends finless treated or decay resistant wood - UDC Sec. 2516 (c)
5. Ends of beams. and girders shall have min. 3" of bearing on masonry or
concrete - UnC Sec. 2517 (c).
13. Floor joists under and parallel to bearing partitions shall be doubled UBC
2517 (d) 5.
14. Floor joists require full depth solid blocking and must lap a min. of 3"
over bearing supports - UBC 2517 (d) 3.
Deems, roof rafters, and ceiling and floor joists shall be supported
laterally in accordance with UBC 2506 (h).
1 » Columna, posts, beams, and girders shall have positive connections provided
to ensure against both uplift and lateral displacement - UBC Sec, 2516 (m).
1 17. Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no
less than 3" on concrete or masonry - UDC Sec. 2517 (c) and (d) 2.
10. withins2"n of etopends
or bottom of ljoint ard� hole joist
diametertlno larger Boredh
than 1/3
depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not
located in middle 1/3 span - UDC Sec. 2517 (d) 3.
1 19. Floor joists and/or roof rafters are insufficient for the span - UBC Table
25 -V -J-1 and UBC Standards.
1 Roof live load (snow load) shall. be 40 pef below 7,000 feet elevation -UDC
Sec. 2305 (d) -dead loads shall be as required In UDC Sec. 2305.
CdcJ"JTV coPV
21. Floor live load nha11 be 40 pnf - UDC Sec.7304 (a) and Table 23-A-1 - dead
loads nhail be nn reguir.ed in UBC Sec. 2304.
2 Unsic wind epcecl n}talI be 00 mph - UDC Sec. 2311..
Uoncler-n over: well openings 4' wide or .leen nitnl.t be. doubled 2" frnmi.ng
lumber on edge. Over 4' wide the bender nhnli be nl.zed for the npnn - UISC
Sec. 2517 (g) 5.
2.4. nearing walls supporting two floor loads are required to be a min. of 3" x
4"or 2"x 6" studs with n max. spacing of 16" on center -UFC Sec. 2517 (g) 1.
25. Wood studs may be cut or notched to a depth not encr;eeding 251 of width In
ext:erior watts and bearing partitions end not exceeding 401 of width in non-
bearing partitions - 1111C Sec. 2517 (g) B.
26. Wood muds may have bored hol.en no greater in diameter than 401 of stud
width, 601 of width of doubled surds (but not more than 2 successive doubled
etude). No holes Weill he bored nearer- than 5/0" to edge of stud - UDC Sec.
2517 (g) 9.
'1J. Wa.1.3 br.rcing rewired 1]oLIr eiders of enc'}' corner- end every 25 1.lnen1. feet -
the braced panel. must be a min. of 40" In width perpendicular to elude - UIC
Sec. 2517 (g) 3-
20. Approximate min. 1.nnnl.aL.Lon vn.lues ere R-19 walla, R-25 toofn, end R-11
floors over unheated space - nee plans for mctt,n specific c tnc(111.rmmnnl:n
"Colorado energy Conservation Standards."
29. Foam plastic insulation shall be separated from the building interior,
including attics and crawl spaces, In nccordance with UDC Sec. 1712. Other
ineninti.on (.(ncl.'tding duct and plenum 1nnulnLI.on and cover.ingn per. UMC
Chapter 10) including facings shnli meet the requiremenln of UDIC Sec. 1713.
30. 1-fasonry and stone veneer units (5" max. In thickness) shall have min. size
of No. 22 gauge by 1" galy. metal lien or No. 9 gauge gnly. wire ties and
epnoed to r.npport not more than 2 sq. ft. of wall nren but not more than 24"
on center horizontally. When applied over surd construction, the studs
shall be max. of 16" on center. Approved building paper must be applied
over the sheathing or studs - UDC Sec. 3006 (d).
31. Ceiling height Is required to he 7'6" In nl1 rooms except ki.tchene, halls,
baihroonrs, and storage areas which may be 7'0" min. e UDC Sec. 1207 (n).--
32. Min. stairway headroom clearance in 6'0" - UDC Sec. 3306 (p).
33. Min. stairway width in 36" - UDC Sec. 3306 (b) and min. landing dimension
in the direction of travel must also be 36" - UDC Sec. 3306 (g) .
34. Stairways ,,cin. run 9"; max. rise 0"; max. variation in rine and run 3/9" -
UI3C Sec. 3306 (c).
35. Enclosed usable space under interior rind exterior_ ntnirwnyn shall be
protected on the enclosed Bide an required for ono -hour fire-renistive
conntrucil.on - UUC Sec. 3306 (m). Fire stops shall be provided in
accordance with UPC Sec. 2516 (f) 2c.
36. Stairway handrails! min. height 34"; max. height 30"; handgrip portion shall
be not Leon than 1 3/2" nor more than 2" In x -section dimension. Min. of
one handrail required on all stairways with more than three risers. Min.
1 1/2" .space required between wall and handrail - UDC Sec. 3306r
37. Guardrails of 36" min. height shall be installed at unencloned• floor
openings and open sides of ntairwayn, landings, ramps, decks or porches more
than 30" above grade or floor below. Open guar.drai.le shall have a pattern
such that a 'sphere 6" In dia. cannot pass through - UDC Sec. 1711.
30. Under -floor (crawl space) cross ventilation in required equal to 1 eq. Et.
for ench 150 sq. ft. of: under -floor area - 1113C Sec. 2516 (c) 6.
39. Under -floor areas shall be provided with n min. 10" by 24" accent, opening --
UDC Sec. 2536 (c) 2. 30" by 30" min. if mechanical equip. In under -floor
area - UMC Sec. 709,
40. All sleeping rooms below the fourth story without a door opening to the
exterior shall have at least one operable window that meets the following
requirements: 11111118111 ulcer (Teeing: 5.7 se. ft.
MAXIMUM sill height; 44"
11111I11t11t net clear opening heights 24" (x34 114" = 5.7 sq.ft.)
MINIMUM net clear_ opening widths 20" (x41" e 5.7 sq. ft.)
This nl.no nppl.ien to basement sleeping roomns - UDC Sec. 1304.
41. Glazing in hazardous locations an defined in UDC Sec. 5406 (glnzing in doors
and oclleeent to doorways, and gl.nzlng in windows located within 19"
vertically of n walking surface) !Anil be safety glazed or protected.
42. Glass in sloped glazing (more than 15 from the vertical.) and skylights
shall meat the requirements of UDC Chapter 34. Skylights and roof and wall
ponela of light -transmitting plastics shall meet the requirements of UBC
Chapter 52.
43. Provide combustion air for fuel burning equipment per. UMC Chapter 6.
44. Pressure relief valves and/or combination pressure/temperature relief valves
shall be provided with a drain line to a floor drain with min. 1" air gap
or extended to the exterior of the building - UPC Sec. 1007.
45. domestic dishwashing machines shall not be directly connected to s drain or
waste disposer without the use of an Approved nirgap - UPC Sec. 608 (d).
46. Fuel burning appliances shall not be located in any room used or designed
to be used as a Bleeping room, bathroom, or closet or any enclosed space
opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless
Hated for such une).
47. Appliances (including space heating and water heating equipment) shall be
accessible for repair and removal In accordance with the UMC.
40. LPG fueled appliances shall not be installed in a pit, under -floor (crawl)
apace, or basement - UMC Soc. 504 (1).
49. Appliances located in a garage (or in an enclosure opening into a garage)
shall be located out of the normal path of vehicles or protected from
damage. Any portion of the appliance creating a flame, spark or glow shall
be Installed a min. of 10" above the garage floor - UMC Sec. 500.
50. Each water clonet stool ahail be located in a clear space not lase than 30"
in width and 24" in front of stool - UDC Sec. 511 (a).
51. Toilet rooms without operable windows shall be equipped with an exhaust
system ducted to the exterior - UOC Sec. 1205 (c).
52. Showers and Tttb/Shower enclosures shall have a smooth, hnrd p nonabsorbent
surface to a height of 70" min. above the drain inlet - UDC Sec. 510 (b).
Water-reaistent gypsum hoard Shall not be used over vapor barriers, in
saunas or steam rooms, or on ceilings -- UDC Sec. 4712.
53. Attic accesd opening of not less than 22" by 30" is required - UDC Sec. 3205
(a). 30" by 30" if mechanical equip. in attic space - UHC Sec. 708.
54. Enclosed attic and rafter spaces shall have crone ventilation of min. 1/150
of the area of the space ventilated. The nrea may be 1/300 if provided
equally at lower and upper portionn of the space with min. 3' vertical
separation of locations, - UBC Sec. 3205 (c).
55. Garage nide of common wall between living space and garage shall be finished
with materials approved for one-hour fire -resistive construction. This also
applies to ceilings and bearing walls if living space above the garage.
Self closing min. 1 3/0" solid , tight fitting door in required between (rouse and
rntnf;e PBC 5103 (d) 3.
56. Electrically wired, interconnected smoke detectors are required in all
sleeping room access areas, near the top of stairways In upper levels, and
near the bottom of stairways to basements - UBC Sec. 1210 (a).
57. Wood gloves and factory built chimneys, and manufactured fireplace units and
venting systems slhaallbe installed in accordance with the manufacturers
listing requirements and inspected during installation UMC Chapter 9 and UBC
Chapter 37.
50. Masonry and concrete fireplaces and barbecues shall meet the requirements
of UDC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any
structural load other than its own weight unless designed as a supporting
member - UDC Sec. 3703 (a). P
59.
60.
COPIES OF TUE ITEMS) CHECKED BELOW ARE ATTACHED (Copies of any of the items
above or below are available upon request).
Excavations, fills, foundations, and retaining walls - UDC Chapters 23 and
29
Retaining walls - Uf3C Sec. 2308 (b) and 2907 (g) 4.
Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in
accordance with UPC Appendix 1)).
Roof sheathing - UDC Sec. 2516 (i).
Wood combined 01th (supporting) masonry or concrete - UBC Sec. 2515.
Floor nheatdring 7 UDC Sec. 2516 (h).
Wiring in plenums - UMC Chapter 10 and NCC.
Fire and draft stops - UBC Sec. 2516 (1).
Nailing requirements for connecting wood members - UBC Sec. 2516 (j).
Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish
chutes - UDC Sec. 1706.
Exterior wall coverings and exterior weather protection - UBC Sec. 1707 (d)
and 2516 (g).
Interior application of gypsum wallboard and interior and exterior
application of lath and plaster - UBC Chapter 47. Manufactured wall and
ceiling covering systems (simulated stucco, etc.) shall be installed in
accordance with manufacturers requirements.
Landings and floor level at doors -- UBC Sec. 3304 (1).
Cross connection control and back flow prevention - UPC Sec. 1002 and 1003.
Treated Woocl Foundation Systems - UBC Standard 29-3.
/
r-
7)/7
.:I
l
/
+ f I
/ j r'r i [` r) I,I
1 .
/
�d (L' 4? GwCCc?
41 1 l
)/)(. C )- C, /0
f"t
O.
r
L 'n r
v 0 (p (
, J. /1 P P
1/4
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 FLOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
A FIELD COUNTY COLORADO
alp
Date ISSneY ..
oned Are Permit No.
AC ME ENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of lire
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
const action of the above described structure, the permit may then be revoked by notice
fr Copnty I3g Inspects an ED .ATE I' ' OM E NULL r OID,
Us
'ma�'yy (r_.
Addrees or Legal Description Oa4 I it)
?,
Own
Setbacks Front Side
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning
Roof Covering
�
Footing _ _
Electric -1{ inal (by STATE inspector)
�. — _ .t; ('- -W
Foundation
Plumbing -Underground
Gas Piping
Heating Ventilation
Frame ]--//,'7Ij g=) -c9"-1-)
Plumbing -Rough
Insulation
Drywall
Electric -12 ough 7 - / 75 - _/ 'i
(by STATE inspector) . c( ,__-�
1'r� na /7-91 - `�
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING --
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
TIIIS PERMIT LS NOT TRANSFERABLE
Phone 945-8212 10 9 8th Street, County Courthouse, Glenwood Springs, Colo.
APP'0 ED
Dater ..K. By
0 NO 1 ESTROY THIS CARD
IF PLACED OUTSIDE COAT R
WITH CLEAR PLASTIC