Loading...
HomeMy WebLinkAboutApplication- PermitJob Address No. 6377 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTML7Vj 109 8th Street Suite 303 Glenwood Springs, Coiorado 81601 (303) 945-8212 0097 Shotgun, Rifle Village South, L-9, B-7, Rifle Nature ofWork Building Permit Use of Building Manu. Home on Foundation Owner Theresa Salazar Contractor Owner Amount of Permit 5 447.09 Date 713197 Permit Pee' $149.75 Plan Check Fee: : $97.34 Set Up Fee: $200.00 Paid $97.34 4/25/97 L. Campbell Clerk BUILDING PERMIT APPLICATION OARFIELD COUNTY, COLORADO Applicant to complete numbered spaces only. PERMIT NO. PARCEUSCHED NO AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPL1LFrtSWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.241 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL J08 ADDRESS DC 9 2 5 ,/]ems/ 1 LEGAL DESCR. LOT NO.9 BLOCK 7 �,//��jj/'io'Q(//�/ SUHOMSIOIV ]� JY i,)[) cA (le 6 V �l . 2 _ I y [� I OWNER FC hard I I\%C�e so SQ1aWr u ADDRESS Z�DOS, 6,ctKhurs'� f In V PH.9L./s.-r'�O 6 1 �j WK PH. qy -- i! j% a_ 3 CONTRACTOR Sall( ADDRESS c PH. LICENSE NO. r 4 �, ��y� ARCHITECT OR DESIGNER ,MII1w 46 E ADDRESS PH, LICENSE NO. 5 ENGINEER ADDRESS PH, LICENSE NO. 6 S.F OF BUILDING /99,3 S.F OF LOT 55 V / ? Q /ti Ol. HEIGHT NO. OF FLOORS 7 USE OF BUILDINGNr 8 CLess OF WORK; NEW ❑`ADDITION n ALTERATION :REPAIR ❑ M�OyVF ❑ REMOVE 9 DESCRIBE WORK. oc1/4 I J \ -4..1. � 1 1 y, � 406 y�eu,J / J yL T VHF � / vTT ir�.w� f►+ `/ �[ „' v��vvvv VM/xi -R/r 4 10 GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN 11 VALUATION OF WORK'S 4. ADJUSTED VAL.S /,3J" � I 3� PLAN CHECK FEr C7 ir PERMIT FEE f J 7 7 � SPECIAL CONDITIONS, �� ! g�x G • 95z co 7 '-^ SCHOOL IMPACT FEE NO. OF BUILDINGS ON PARCEL USE OF BUILDINGS NOW ON PARCEL � f TOTAL / 1/7. 09' OCC. GR/'? 3 CONST. TYPE V NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL PLUMBING, HEATING, VENTILATING OR AR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FOR A PERIOD OF l80 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DO' •-ESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIO OTHER STATE DR LOCAL LAW REGULATING CONSTRUCTION •' PERFO-MANCE OF CO : RUCTION. ..i J , 1......L./... LI 'T �y / y WATER SUPPLY N DATE PERMIT ISSUED SPECIAL APPRCVALs REOUIREO RECE o NOT REQUIRED ZONING i-----*/ HEALTH DEPT. FIRE DEPT SOIL REPORT ' / SETBACKS FLOOC•FIAZARD Signature of - Contractor or aL anzed ages r •'�• �'" non _ MANUF. HOME d V Building r_partmentAoprovaldat- ]'Planni . -Dart ntAporovalldaW J OTHER AGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPL1LFrtSWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.241 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL The following items are required by Garfield County for a final inspection: 1. A final Electrical Inspection from the Colorado State Electrical Inspector; 2, Permanent address assigned by Garfield County Budding Department posted where readily visible from access road; 3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows installed, a complete kitchen with cabinets, a sink with hot & cold running water, non-absorbent kitchen floor coverings, counter tops and finished walls, ready for stove and refrigerator, all necessary plumbing; 4. A complete bathroom, withwash bowl, tub or shower, toilet stool, hot and cold running water, non-absorbent floors and walls finished and a privacy door; 5. All steps outside or inside over three (3) steps must have handrails, guard rails on balconies or decks over 30" high constructed to all 1994 UBC requirements; 6. Outside grading done to where water will detour away from. the building, 7 Exceptions to the outside steps, decks and grading maybe made upon the demonstration of extenuating circumstances, i.e. weather, but a Certificate of Occupancy will not be issued until all the required items are completed and a final inspection made A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE ITEMS HAVE BEEN COMPLETED. ****Cannot occupy or use dwelling until a Certificate of Occupancy (C.O.) is issued. Occupancy or use of dwelling without a C.O. will be considered an illegal occupancy and may be grounds for vacating premises until above conditions are met. 1 understand and agree to abide by the above conditions for occupancy, use and the issuance of a Certificate of Occupancy for the dwelling under building permit # Signature Date 4.. .6.-- c4rtocs e (—A rey).1-01, 5/1,4-&(/1) r• b —2 0 5-c A., 1-e 6/Y-e-A-ek ao VSilpu>4 #e" ,20_ 1,15" x s41 ///94( */ir 4,66 gq 4J-/ s,7 a o a 0 rcr Apr. 25. 1997-21:02AM STEWART TITLE GLid'rVO Na. 0018 P, 1/1 Recorded az o'clock M., QUIT CLAIM DEED THIS DEED, Mede this 4th day of Apr i.1 , 19 97 , baweett JOE FRED CI►SALYS of the said County of EAGLE SEMNNWN and THERESA SALAZAR and State of COLORADO , grantor, and RICHARD D. SALAZAR .-hose legal address is 2600 SO. OAJZEURST #4 GLENWOOD SPRINGS CO 61601 of the said County of GARFIELD and State of COLORADO , grantee: df -0- WITNESS, that the grantor, for and is consideration of the sum of TEN & 00/100 DOLLARS, the receipt and ruff/de-icy of which is hereby acknowledged, trot remised, released, sold, conveyed, and QUIT CLAIMED, and by these presents, do realise, relea e, seam convey and Quit Claim unto the grantee., his heirs, successors and assigns, forever, all the right, tide, intucst, claim and demand which the granter has in and to the real property, together with improvements, if any, situate, lying and being in the said County of camp/Imp and State of Co[orado de cribed as follows - LOT 9 BLOCK 7 RIFLE VILLAGE SOUTH SUBDIVISION, FIRST FILING COUNTY OF GAR.F I ELD STATE OF COLORADO GARFIELLD COUNTY ASSESSORS NO; 2177-202-02-009 PROVIDED FOR INFORMATIONAL PURPOSES ONLY as known by street and number as: VACANT LAND, RIFLE CO 81650 TO HAVE AND TO HOLD the same, together with all and singular the appurtenances and privileges thcrcunto belonging of in any- wise thereunto apperuining, and all the estate, right, tit]e, interest and claim whatsoever, of the grantor, either in kw or equity, to the only proper vac, benefit and behoof of the grantee, his heirs and assigns forever. The singular number 'hail include the plural, the plural and the singular, and the use of any gender shall be applicable to all genders. IN W ThESS WHEREOF, the grantor has executed this deed on the data set forth above. State of COLORADO ) )ser. County of EAGLE The foregoing instrument was acknowledged before me this l f day of April 1997 by JOE FRED CASAUS My cotarniaa ion expires 1 a 1ab :Witae s my hand and official seal. Notary Public }Th Na s7J i:£412 46terrat Talc .l Cl-rwrona ;Once,. :n4. Rev. 5 —RETURN: Teresa Salazar 2600 Oakhurst #4 Glenwood Springs, CO 61601 • CITY OF RIFLE APPLICATION FOR RESIDENTIAL WATER'AND SEWER SERVICE P O Property weer F'% ea G 54145 Addition 1e//cLe////6 _vZ/ Address Contractor Address reizess 54z r im;>rin,Q Block 7 Lot(s) v �J 9 DESCRIBE Type of Structure Valuation Bedrooms Bathrooms TOTAL NO. Backflow Device Required Sprinkler System Hose Bibs Sq.Ft. of Lot MOBILE HOME UNITS ARE RATED THE SAME AS SINGLE FAMILY. OUT -OF -CITY TAPS SHALL BE DOUBLE FEES. MATERIAL AND LABOR FOR INSTALLATION OF THE SEWER AND WATER TAP WILL BE PAID FOR BY THE OWNER. WATER FEE SHALL BE BASED UPON SIZE OF LOT. Water System Improvement Fee Sewer System Improvement Fee Water Rights Dedication Fee CO Water Meter (Size'/4 A� `5 Inspection Fee O ij�Q. 1-. Water Meter Installation Fee SUBTOTAL Building Permit # Plan Review Fee = 5% J2.6..00 2 to OD izo 0 0 Multi -Family Units X Multi -Family Units X Water System Improvement Fee (In -City) Lot size up to 7,000 sq. ft. Lot size between 7,001-8,500 sq. ft. Lot size over 8,500 sq.ft. " S er System Improvement Fee (In -City) Single Family Residential per unit -Multi-family Residential per Unit Si 250.00 1. Jon.' $1,177.00 $824.00 TOTAL Installer Mobile Home (Individual or Master Meter) $1,177.00 City Engineer Building Inspector City Clerk Copies: Bldg.File Applicant Water Dept. C:ldoelbidglapplieat. w&a 4ed- / CeLt..47J v / Sieskte0 ' % �/ L z -+rim. Date Date Date Date GARFIELD COUNTY BUILDING AND PLANNING 970-945-8212 MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION MANUFACTURED HOMES ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan. review. If you do not, it may be helpful to obtain a book titled "Dwelling Construction under the Uniform Building Code". This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are require to indicate appropriately and to submit the completed check list.at time of application for a permit. For the placement of a manufactured home, questions numbers 1-4 and 19-28 are the only questions that need to be addressed: 1 Is a site plan included that indicates the distances of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes �. Does the site plan include the location of the I.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties), streams or water courses? Yes Does the site plan indicate the location and direction of the County or private road accessing the 7 prope Yes Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes 5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes 6. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces and soffits? Yes Do the plans include design loads as required under the Uniform Building Code for roof snow loads, (a minimum of 40 pounds per square foot in Garfield County), floor loads and wind loads? Yes Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? _ Yes 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes 2 11. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the cave down to existing grade contours? Yes 1?. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes No 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No 14. Does the plan include a window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes No 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes No 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No 17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No 18. Do you understand that if you belong to a homeowners association, it is your responsibility to obtain written permission fro the association, if required by that association, prior to submitting an application for a building permit? Yes No 19. Will this be the only residential structure on the parcel? Yes ( No If no -Explain: 20. Have two (2) complete sets of construction drawings been submitted with the application? Yes 3 72 Is this an application for the placement of a manufactured home? Yes No If yes, have you specified the size of the unit (min. 20ft. x 20ft); live roof load (min. 404); wind design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring? Yes Have you designed or had this plan designed while considering building and other construction code requirements? Yes No v 23. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield County Building Department? Yes \l' No 24. Do you understand that approval for design and/or construction changes are required prior to the appiicat�io� of these changes? Yes ice No 25. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School Impact" or Septic System fees required, at the time you pick up your building permit? Yes No 26. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00 p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before. Failure to give twenty four (24) hour notice for inspections will delay your inspection one (1) day? Yes No 27. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes No 28. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, is the party responsible for the project complying with the Uniform Building Code? Yes ) No 4 I hereby acknowledge that I have read, understand and answered these questions to the best of my -ability. Phone: CILI 5 /lfsz (days); -97 d ate (evenings) Project Name: Pia Ce ryt o f M a ±1+o ( c4 Project Address: (4j- q /a C x s' /lo+ rl r\ Ca 81(95-6 Notes: Pc, RiLff If you have answered "No" on any of the questions. you mai' be required to provide this information at the request of the Building, Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of a permit If it is determined by the Building Official that additional information is necessary to review the application and plans to determine minimum compliance with the adopted codes; the application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with construction. PerAppO2.95 Effective August 15, 1995 5 f' INSPECTION WILL NOT BE .MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 I1OURS NOTICE REQUIRED FOR INSPECTIONS BUILD1NG PER.MIT GARFIELD COUNTY, COLORADO Date Issued/ k77 Vi.""' Zoned Area. Permit No7 AGREEMENT In consideration of the issuance of This permit, the applicant hereby agrees to'comply will all . laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspecto, : nd 1MM.EDIA ELY BECOME N . ' NI) VOID. Use Addr' egal Descrip ' n_ n Setbacks This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection. FDA( Side Cultimc Side Rear 5 1 INSPECTION RECORD Footing 7 t7 9 2 A J Foundation [underground Plumbing Rough Plumbing Insulation Drywall Chimney & Vent Gas Piping Electric Rough (By State Inspector) Framing (To include Roof in place and Windows and Doors installed). Electric Final (by Stale inspector) Final 5 Septic Final Notes: ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado. HIS CARD APPROVEDD° NOT DESTROY DateB ! t►�/ . ' �� Y.41 IF PLACE OUTSIDE - COVER WITH CLEAR PLASTIC