HomeMy WebLinkAboutPlansRanch At Roaring Fork HOALot Proposed Pump House Proposed Wet Well \ \ WaterTronics Vertical Turbine \ Pump Station \ (By Others) \ Floor Drain To Daylight Proposed Building Access Road se Existing Communications Line to Well House GRAPHIC SCALE 20 corP/ ncrete Channel 15 Lin. Feet. New Intake Structure I / Invert Elev. 6239.00 \rD ° / \ \ \ ofi \ \ \ \ \ 55' of 24" ADS N-12 Pipe \ Existing Wet Well Building (To Be Removed) Wetlands i \ 6'a \ \ \ ,-- N -__ = \ \ '-\ \ CD \\ \ \ \,- N - \ E7( / -i.E \ \ \ ,/ \\\ \ \\ \ \ \ \ / / 1\� \, 1 \, \4 \1 \ (1 Proposed Electrical 2-2" Conduits For I New Wellhouse Power And for Pumphouse ) , / l / / i / / // / ,' / / `.- // // / //� 1 / / Exiting Electrical Pedestal Exiting Electrical To Be Removed to Pedestal Proposed Electric In 2" Conduit For Existing Well / 40 ( IN FEET ) 1 inch = 10 ft. J ng Electric be rerouted In 2" conduit Pumphouse r Wellhouse Sawcut Concrete Channel Upstream of New Plug / \ // /\\ice / \/ // // // // — Thrust Block Proposed New Path Existing Trail UE UE / 7' / / 7 / 7' /_ Ex-LE1-EX-SIE---c..�-- 6245 Existing Culvert - — -- / (To Remain) ` UE UE utuE / 4 UE \ 7- I. \-- Existing Grade Proposed Grade 5% Slope to Grade 1.5' of 1.5" Screened Rock Around Wet Well Proposed Trail Waterline r ! s� Pump Station /..----- Not Shown for Clarity 1 1 1 1 CD LOT 7 Waterline To Be Centered in Easement iMMEI LOT 8 New Wet Well Invert Elev. 6237.00 0 0 0 0 • • • 0 • • • • • 0 0 0 0 0 0 Proposed Pumphouse Pumphouse Finished Floor Elev. 6249.00 3: siope New Intake Structure Invert Elev. 6239.00 CD CD REV. NO. DATE REVISION MADE BY CHKD BY APPD BY Ranch at Roaring Fork Golf Course Pumping Station SCALE: DATE: November 23, 2015 DRAWN BY: BCE CHKD BY: BCE APPD BY: BCE SHEET: 1 OF DRAWING: Site Plan Ranch at Roaring Fork POST OFFICE BOX 1908 — 1011 GRAND AVENUE GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5700 SHEET NO. PROJECT: 218XX JA,LOI /, 1 \ \ \\ I / \ / \ 1 55' of 24" ADS N-12 Pipe Ex -LE Exiting Electrical Pedestal Proposed Electric In 2" Conduit For Existing Well � L \ Sawcut Concrete Channel Upstream of New Plug Existing Culvert ` -- (To Remain) E Existing Wet Well Building (To Be Removed) Exiting Electrical To Be Removed to Pedestal Wetlands 4 \CS', �tss \ Proposed Electrical 2-2" Conduits For 6245 New Wellhouse Power // e / // / / / / / / / / And for Pumphouse / / 1 1 1 1 • 0+50 UE LE UE UE A LOT 7 Waterline To Be Centered in Easement +f 1 1 EI -UE EX- E EX -UE E7t-UE EX -UE EX -UE ���r•r�r���_._. -1E EX -UE EX -UE EX -UE EX -UE EX -IE EX -LE EX � EX 10"HDPE DR7 Waterline Proposed Trail Class 6 Base Course • 1 1 1 n CD 12'-0" Typical Access Road Section Scale: Y4" = 1' LOT 8 0 ami (D CD 8'-0" Class 6 Base Course !,0v4wei..,i.wel.,ei..w4 .off.S'..S'.S'.,l Typical Path Section Scale: Y4" = 1' 1 1 1 11 3+00 / / / / 1 1 1 1 i 1 1 1 r REV. NO. DATE REVISION MADE BY CHKD BY APPD BY Ranch at Roaring Fork Golf Course Pumping Station SCALE: 1" = 5' DATE: November 23, 2015 SHEET: 1 OF DRAWN BY: BCE CHKD BY: BCE APPD BY: BCE DRAWING: Site Plan Ranch at Roaring Fork Z,,4NC,4NE/ / / AND ASSOC/ATE-5, /NC ENG'/NEE/?/NC CONS/TANTS POST OFFICE BOX 1908 — 1011 GRAND AVENUE GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5700 SHEET NO. C2 PROJECT: 218XX