HomeMy WebLinkAboutEngineer's System Design Packet 04.12.2017ALL SERVICE April 12, 2017 33 Four Wheel drive Rd Carbondale, Co 81623 970-309-5259 Bruce Upton Bear Creek Construction Bruce.bearcreek@comcast.net Septic Tank Design Proposed Tractor Shed with Sink and Toilet 3925 CR 154 Garfield County, Colorado Bruce, Project No. C1282 ALL SERVICE septic, LLC performed septic tank design for a proposed tractor shed. The property is located outside of Glenwood Springs, in an area where OWTSs and wells are necessary. SITE CONDITIONS An existing onsite wastewater treatment system (OWTS) serves the existing cabin on the property. Garfield County Building and Sanitation Department Individual Sewage Disposal System Permit 1685 documents the original portion of the OWTS. This consists of a Copeland 1000 -gallon, two- compartment concrete septic tank and an 18' x 30' soil treatment area (STA). This permit received final approval from Garfield County on July 31, 1989. The development on the property changed in approximately 2011. At that time, ALL SERVICE septic, LLC designed a septic tank with a pumping system that would pump wastewater from a new septic tank serving a cabin to the original (1989) septic tank. An additional septic tank with a pumping system is proposed to serve the proposed tractor shed. The original septic tank and STA serving the cabin is located slightly uphill of the new, proposed septic tank. As a result, wastewater from both the septic tank serving the cabin and the proposed septic tank serving the proposed tractor shed will be pumped to the original OWTS which was permitted in 1989. We inspected the existing septic tank (2011) and found it to be in good condition. There are no drawings of the original STA and no access to the STA for inspection. We recommend using a camera to locate the route of the sewer line and the approximate location of the original STA. Without access, there is no way to assess the condition of the STA and therefore; this office makes no warranty regarding the condition or future functioning of the STA. There are no wells within 50 -feet of the proposed septic tank. DESIGN SPECIFICATIONS ALL SERVICE septic, LLC has been asked to design a septic tank with a pumping system for the proposed tractor shed. Plumbing fixtures in the tractor shed include a toilet and a sink that will be an auxiliary use to the cabin on the property. A clean out will be installed within 5 -feet of the tractor shed. The sewer line from the tractor shed to the septic tank must have a minimum 2% slope. The installation will include a new 1000 -gallon, two- Page 2 compartment concrete septic tank. An Orenco® ProPak Pump Package with an Orenco® PF3005 pump' will be installed in the second compartment of the septic tank. The pump floats must be set to does approximately 70 gallons each pump cycle (allowing for 25 gallons of drain back). The control panel for the pumping system must be installed within line of sight of the septic tank. A 2 -inch diameter Schedule 40 pump line with a minimum 1% slope for drain back must be installed from the septic tank that will serve the tractor shed to the existing septic tank. We visited the property on March 30, 2017 and determined there was approximately 130 to140-feet of distance between the proposed septic tank and original (1989) septic tank and an elevation difference of 1 -foot 10 -inches if the existing top of original (1989) septic tank is at 97'10" and the top of the proposed septic tank to serve the tractor shed is set at 96'. We recommend entering the existing septic tank through the inlet knock out, into an inlet tee to minimize turbulence in the septic tank. We recommend installing an Orenco® Biotube Effluent Filter on the outlet of the original (1989) 1000 -gallon septic tank. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Garfield County On -Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo -fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STAs. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener ' A high -head pump has been specified so it may be utilized in the future if a new STA is to be constructed. Page 3 should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3 -inch. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC Carla Ostberg, MPH, REHS Reviewed By: Pump Selection for a Non -Pressurized System - Single Family Residence Project 3925 CR 154 / Garfield County, Colorado Parameters Discharge Assembly Size 1.25 inches Transport Length 140 feet Transport Pipe Class 40 Transport Line Size 2.00 inches Distributing Valve Model None Max Elevation Lift 1.5 feet Design Flow Rate 10 gpm Flow Meter None inches 'Add-on' Friction Losses 0 feet Calculations Transport Velodty 0.9 fps Frictional Head Losses Loss through Discharge Loss in Transport Loss through Valve Loss through Flowmeter 'Add-on' Friction Losses Pipe Volumes 0.7 feet 0.3 feet 0.0 feet 0.0 feet 0.0 feet Vol of Transport Line 24.4 gals Minimum Pump Requirements Design Flow Rate 10.0 gpm Total Dynamic Head 2.5 feet Orenco Systems' Incorporated Changing the Way the Wel Does Warre:twee Total Dynamic Head, TDH (Feet) Pu m p Data 10 15 20 25 30 35 40 Net Discharge (gpm) PF3005 High Head Effluent Pump 30 GPM, 1/2HP 115/230V 10 60Hz,200t/ 3060Hz PF3007 High Head Effluent Pump 30 GPM, 3/4HP 230V 10 60Hz, 200/460V 30 60Hz PF3010 High Head Effluent Pump 30 GPM, 1HP 230V 10 60Hz, 200/460V 30 60Hz PF3015 High Head Effluent Pump 30 GPM, 1-1/2HP 230V 10 60Hz, 200/230/460V 3060Hz Legend System Curve: Pump Curve: Pump Optimal Range Operating Point: Design Point() DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 04/12/17 0' 15' 30' Scale: 1" = 30'-0" EXISTING 1000 -GALLON, TWO COMPARTMENT SEPTIC TANK WITH AN ORENCO PUMPING SYSTEM IN THE SECOND COMPARTMENT (CONTROL PANEL IN THE CABIN) EXISTING 2 -INCH DIAMETER PUMP LINE EXISTING 1000 -GALLON, TWO-COMPARTMENT COPELAND CONCRETE SEPTIC TANK (1989) NEW 2 -INCH DIAMETER PUMP LINE (MIN. 1% SLOPE FOR DRAIN BACK INTO SEPTIC TANK) NEW, 1000 -GALLON, TWO-COMARTMENT CONCRETE SEPTIC TANK WITH ORENCO PUMPING SYSTEM IN THE SECOND COMPARTMENT 4 -INCH DIA SEWER LINE FROM TRACTOR SHED TO SEPTIC TANK (MIN. 2% SLOPE TO TANK) CLEAN OUT (CLIENT REQUESTED ONE-WAY) existing gr vel drive ay / new electrical service route from existing service SI ' LAN 30'-0 ALL SERYICI 33 Four Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 carla@allserviceseptic.com n Macgregor Property 3925 CR 154 Garfield County, Colorado Project Number: C1282 ate: 04/12/17 esigned By: CBO R viewed By: RHP Drawn By: ANG W1.0 Sheet 1 of 1 Residential Biotube® Effluent Filters Applications Our patented* 4 -in. (100 -mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. 4 -in. (100 -mm) Biotube Effluent Filter 4 -in. (100 -mm) Biotube Jr. (4 -in. Biotube cartridge avail- able separately as Insert Filter) 8 -in. (200 -mm) 4 -in. (100 -mm) Base Inlet Filter Insert Filter Orenco's superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4 -in. (100 -mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4 -in. (100 -mm) Biotube Jr, at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low profile tanks, there's the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS -FT -1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. Standard Features & Benefits • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal Optional Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion -proof construction, to ensure long life • Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes' entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. Cal Orenco Systems" I ncorporated Changing the Way the World Does Wastewater° www.orenco.com Nomenclatures 4 -in. Biotube Filter (standard) FT 04 I Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard Housing height: 36" and 44" are standard Filter diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series 8 -in. Biotube Filter (base inlet model) FT 08 22 -14 B Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filte diameter (inches) 08 = 8" Blank = 1/8" filtration P = 1/16" filtration Biotube effluent filter series * Also available with coupling and sleeve as a "kit": FT-OVERFLOWKIT 4 -in. Biotube Jr. (includes cartridge and housing) FT J 04 18 Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height (inches) Filte diameter (inches) fits Type 3034 outlet tee fits Schedule 40 outlet tee W= s= Blank = 1/8" filtration P = 1/16" filtration Junior series Biotube effluent filter series 4 -in. Biotube Filter Insert (cartridge only) FTi 0418 - For customized options (e.g., NC indicates North Carolina regions) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filte diameter (inches) Blank = 1/8" filtration P = 1/16" filtration Insert Biotube effluent filter series 4 -in. Biotube Effluent Filter Extendible PVC handle 4 -in. Biotube Jr. Stainless steel set screws Top seal plate Air vents Biotubefilter cartridge )000( Solid base — Riser a wall Filter housing / Distributed By: Orenco® Technical Data Sheet Biotube® ProPak Pump PackageTM 60 -Hz Series Pump Packages Float bracket External splice box Optional; internal splice box comes standard.) Control panel Riser lid (not included) — Riser (not included) Discharge assembly Support pipe Pump vault Float stem Floats Float collar Vault inlet holes 4 -in. (100 -mm) turbine effluent pump Biotube® filter cartridge Pump liquid end Pump motor Biotube© ProPakTM pump package components. General Orenco's Biotube® ProPak"" is a complete, integrated pump package for filtering and pumping effluent from septic tanks. And its patented pump vault technology eliminates the need for separate dosing tanks. This document provides detailed information on the ProPak pump vault and filter, 4 -in. (100 -mm) 60 -Hz turbine effluent pump, and control panel. For more information on other ProPak components, see the following Orenco technical documents: • Float Switch Assemblies (NSU -MF -MF -1) • Discharge Assemblies (NTD -HV -HV -1) • Splice Boxes (NTD -SB -SB -1) • External Splice Box (NTD -SB -SB -1) Applications The Biotube ProPak is designed to filter and pump effluent to either gravity or pressurized discharge points. It is intended for use in a septic tank (one- or two-compartment) and can also be used in a pump tank. The Biotube ProPak is designed to allow the effluent filter to be removed for cleaning without the need to remove the pump vault or pump, simpli- fying servicing. Complete packages are available for on -demand or timed dosing sys- tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 Usec), as well as with 50 Hz and 60 Hz power supplies. Standard Models BPP2ODD, BPP2ODD-SX, BPP3OTDA, BPP3OTDD-SX, BBPP5OTDA, BPP5OTDD-SX Product Code Diagram BPP Standard options: Blank = 57 -in. (1448 -mm) vault height, internal splice box, standard discharge assembly 68 = 68 -in. (1727 -mm) vault height SX = external splice box CW = cold weather discharge assembly DB = drainback discharge assembly D = cam lock MFV = non -mercury float Control panel application: DD = demand -dosing TDA = timed -dosing, analog timer TDD = timed dosing, digital timer, elapsed time meter & counters Pump flow rate, nominal: 20 = 20 gpm (1.3 Usec) 30 = 30 gpm (1.9 L/sec) 50 = 50 gpm (3.2 Usec) Biotube® ProPak'" pump vault Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD -BPP -1 Rev. 1.2, © 08/14 Page 1 of 4 ProPakTM Pump Vault Materials of Construction Vault body Polyethylene Support pipes PVC Dimensions, in. (mm) A - Overall vault height B - Vault diameter 57 (1448) or 68 (1727) 17.3 (439) C - Inlet hole height 19 (475) D - Inlet hole diameter (eight holes total) E - Vault top to support pipe bracket base F - Vault bottom to filter cartridge base 2 (50) 3 (76) 4 (102) E A C V E B • 1 ProPakTM pump vault (shown with Biotube filter and effluent pump) Biotube° Filter Cartridge Materials of Construction Filter tubes Polyethylene Cartridge end plates Polyurethane Handle assembly PVC Dimensions, in. (mm) A - Cartridge height 18 (457) B - Cartridge width 12 (305) Performance Biotube® mesh opening Total filter flow area 0.125 in. (3 mm)* 4.4 ft2 (0.4 m2) Total filter surface area 14.5 ft2 (1.35 m2) Maximum flow rate *0.062 -in. (1.6 -mm) filter mesh available 140 gpm (8.8 t -/sec) g. OC ggg ggg Biotube° filter cartridge (shown with float switch assembly) NTD -BPP -1 Rev. 1.2, © 08/14 Page 2 of 4 Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com Technical Data Sheet Orenco® 4 -in. (100 -mm) Turbine Effluent Pumps Pump Curves Orenco's 4 -in. (100 mm) Turbine Effluent Pumps are constructed of lightweight, corrosion -resistant stainless steel and engineered plastics; all are field -serviceable and repairable with common tools. All 60 -Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, and meet UL requirements. Power cords for Orenco's 4 -in. (100 -mm) turbine effluent pumps are Type SOOW 600-V motor cable (suitable for Class 1, Division 1 and 2 applications). Materials of Construction Discharge: Stainless steel or glass -filled polypropylene Discharge bearing: Engineered thermoplastic (PEEN Diffusers: Glass -filled PPO Impellers: Acetal (20-, 30-gmp), Noryl (50-gpm) Intake screens: Polypropylene Suction connection: Stainless steel Drive shaft: 300 series stainless steel Coupling: Sintered 300 series stainless steel Shell: 300 series stainless steel Lubricant: Deionized water and propylene glycol Specifications Nom. flow, Length Weight gpm (Usec) in. (mm) Ib (kg) Discharge Impellers in., nominal 1 20 (1.3) 22.5 (572) 26 (11) 1.25 30 (1.9) 21.3 (541) 25 (11) 1.25 50 (3.2) 20.3 (516) 27 (12) 2.00 4 3 2 Performance Nom. flow, gpm (Usec) 20 (1.3) 30 (1.9) 50 (3.2) hp (W) Design Rated Min liquid flow amps cycles/day level, in. (mm) 2 0.5 (0.37) 12.3 300 18 (457) 0.5 (0.37) 11.8 300 20 (508) 0.5 (0.37) 12.1 300 24 (610) ' Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco Distributor about fittings to connect discharge assemblies to metric -sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® ProPakTM Pump Vault. Pump curves, such as those shown here, can help you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure (TDH), providing a graphical representation of a pump's performance range. Pumps perform best at their nominal flow rate, measured in gpm or Usec. 140 120 a p 100 1- a z 80 E 60 40 20 Flow 'n liters per second (L/sec) 0.63 1.26 1.89 2.52 3.15 3.79 4.42 PF 200511 —1PF 300511 ..1 —1 PF 5005111 10 20 30 40 50 60 70 Flow in gallons per minute (gpm) 43 37 30 24 18 12 6 Total dynamic head (TDH) in meters Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD -BPP -1 Rev. 1.2, © 08/14 Page 3 of 4 Orenco° Technical Data Sheet Control Panel (Demand Dose) Orenco's ProPak'" demand dose control panels are specifically engineered for the ProPak pump package and are ideal for applications such as demand dosing from a septic tank into a conventional gravity drainfield. Materials of Construction Enclosure UV -resistant fiberglass, UL Type 4X Hinges Stainless steel Dimensions, in. (mm) A - Height 11.5 (290) B - Width 9.5 (240) C - Depth 5.4 (135) Specifications Panel ratings 1. Motor -start contactor 120 V, 3/4 hp (0.56 km, A, single phase, 60 Hz 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA) 2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers 3. Toggle switch 4. Audio alarm Single -pole, double -throw HOA switch, 20 A 95 dB at 24 in. (600 mm), warble -tone sound, UL Type 4X 5. Audio alarm 120 V, automatic reset, DIN rail mount silence relay 6. Visual alarm 7/8 -in. (22 -mm) diameter red lens, "Push -to -silence," 120 V LED, UL Type 4X 0 n Control panel, demand -dose Control Panel (Timed Dose) Orenco's ProPak timed dose control panels are specifically engineered for the ProPak pump package and are ideal for applications such as timed dosing from a septic tank into a pressurized drainfield or mound. Analog or digital timers are available. Materials of Construction Enclosure UV -resistant fiberglass, UL Type 4X Hinges Stainless steel Dimensions, in. (mm) A - Height 11.5 (290) B - Width 9.5 (240) C - Depth 5.4 (135) Specifications Panel ratings Dual -mode la. Analog timer (not shown) 120 V, 3/4 hp (0.56 kV , 14 A, single phase, 60 Hz Programmable for timed- or demand -dosing (digital timed -dosing panels only) 120 V, repeat cycle from 0.05 seconds to 30 hours. Separate variable controls for OFF and ON time periods 1 b. Digital timer (shown below) 120-V programmable logic unit with built-in LCD screen and programming keys. Provides control functions and timing for panel operation 2. Motor -start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA) 3. Circuit breakers 120 V, 10 A, OFF/ON switch. Single pole 120 V 4. Toggle Switch 5. Audio alarm Single -pole, double -throw HOA switch, 20 A 95 dB at 24 in. (600 mm), warble -tone sound, UL Type 4X 6. Visual alarm 7/8 -in. (22 -mm) diameter red lens, "Push -to -silence", 120 V LED, UL Type 4X Control panel, timed -dose (digital timer model shown) NTD -BPP -1 Rev. 1.2, © 08/14 Page 4 of 4 Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com Orenco® Technical Data Sheet PF Series 4 -inch (100 -mm) Submersible Effluent Pumps Applications Our 4 -inch (100 -mm) Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or separate dosing tanks. All our pumps are constructed of lightweight, corrosion -resistant stainless steel and engineered plastics; all are field - serviceable and repairable with common tools; and all 60 -Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, meeting UL requirements. Orenco's Effluent Pumps are used in a variety of applications, including pressurized drainfields, packed bed filters, mounds, aerobic units, effluent irrigation, effluent sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube° pump vault or after a secondary treatment system. Franklin Liquid End Franklin Super Stainless Motor S4® C US LR80980 LR2053896 Discharge Connection — Bypass Orifice — Suction Connection 0 Powered by Franklin Electric Features/Specifications To specify this pump for your installation, require the following: • Minimum 24-hour run -dry capability with no deterioration in pump life or performance* • Patented 1i8 -inch (3 -mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind • Liquid end repair kits available for better long-term cost of ownership • TRI-SEALTM floating impeller design on 10, 15, 20, and 30 gpm (0.6, 1.0, 1.3, and 1.9 L/sec) models; floating stack design on 50 and 75 gpm (3.2 and 4.7 L/sec) models • Franklin Electric Super Stainless motor, rated for continuous use and frequent cycling • Type SOOW 600-V motor cable • Five-year warranty on pump or retrofit liquid end from date of manu- facture against defects in materials or workmanship Not applicable for 5 -hp (3.73 kW) models Standard Models See specifications chart, pages 2-3, for a list of standard pumps. For a complete list of available pumps, call Orenco. Product Code Diagram PF Cord length, ft (m): Blank = 10 (3) 20 = 20 (6) 30 = 30 (9) 50 = 50 (15) Voltage, nameplate: 1 = 115* 200 = 200 2 = 230* 4 = 460 Frequency: 1 = single-phase 60 Hz 3 = three-phase 60 Hz 5 = single-phase 50 Hz Horsepower (kW): 03 = 1/3 hp (0.25) 07 = 3 hp (0.56) 15 = 1-Y2 hp (1.11) 30 = 3 hp (2.24) Nominal flow, gpm (L/sec): 10 = 10 (0.6) 15 = 15 (1.0) 20 = 20 (1.3) 30 = 30 (1.9) 50 = 50 (3.2) 75 = 75 (4.7) 05 = 12 hp (0.37) 10=1hp(0.75) 20 = 2 hp (1.50) 50 = 5 hp (3.73) Pump, PF Series Y2 -hp (0.37kw) only *220 volts for 50 Hz pumps 'Note: 20 -foot cords are available only for single-phase pumps through 1-1/2 hp Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 1 of 6 Specifications, 60 Hz Pump Model N cn E iv y «9 ti aQi 3 R o = c V�• N ) R R Ql H R iN N i§- R E ate(R R O S d Z> Q ▪ 0 CO rL Length, in. (mm) Rated cycles/day PF100511 10 (0.6) 0.50 (0.37) 1 115 120 12.7 12.7 6 1 1/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF100512 10 (0.6) 0.50 (0.37) 1 230 240 6.3 6.3 6 1 1/4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF10053200 10 (0.6) 0.50 (0.37) 3 200 208 3.8 3.8 6 1 Y4 in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF100712 4, 5 10 (0.6) 0.75 (0.56) 1 230 240 8.3 8.3 8 1 1/4 in. GFP 25.9 (658) 17 (432) 30 (14) 300 PF10073200 4, 5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 1/4 in. GFP 25.4 (645) 17 (432) 31 (14) 300 PF101012 5' 6 10 (0.6) 1.00 (0.75) 1 230 240 9.6 9.6 9 1 '/4 in. GFP 27.9 (709) 18 (457) 33 (15) 100 PF10103200 5, 6 10 (0.6) 1.00 (0.75) 3 200 208 5.5 5.5 9 1 1/4 in. GFP 27.3 (693) 18 (457) 37 (17) 300 PF102012 5' 6, 7, 8 10 (0.6) 2.00 (1.49) 1 230 240 12.1 12.1 18 1 14 in. SS 39.5 (1003) 22 (559) 48 (22) 100 PF102032 5'6'8 10 (0.6) 2.00 (1.49) 3 230 240 7.5 7.6 18 1 '/4 in. SS 37.9 (963) 20 (508) 44 (20) 300 PF10203200 5'6'8 10 (0.6) 2.00 (1.49) 3 200 208 8.7 8.7 18 1 Y4 in. SS 37.9 (963) 20 (508) 44 (20) 300 PF150311 15 (1.0) 0.33 (0.25) 1 115 120 8.7 8.8 3 1 �/4 in. GFP 19.5 (495) 15 (380) 23 (10) 300 PF150312 15 (1.0) 0.33 (0.25) 1 230 240 4.4 4.5 3 1 '/4 in. GFP 19.5 (495) 15 (380) 23 (10) 300 PF200511 20 (1.3) 0.50 (0.37) 1 115 120 12.3 12.5 4 1 '/4 in. GFP 22.3 (566) 18 (457) 25 (11) 300 PF200512 20 (1.3) 0.50 (0.37) 1 230 240 6.4 6.5 4 1 Y4 in. GFP 22.5 (572) 18 (457) 26 (12) 300 PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 '/4 in. GFP 22.3 (566) 18 (457) 26 (12) 300 PF201012 4, 5 20 (1.3) 1.00 (0.75) 1 230 240 10.5 10.5 7 1 '/4 in. GFP 28.4 (721) 20 (508) 33 (15) 100 PF20103200 4' 5 20 (1.3) 1.00 (0.75) 3 200 208 5.8 5.9 7 1 Y4 in. GFP 27.8 (706) 20 (508) 33 (15) 300 PF201512 4, 5 20 (1.3) 1.50 (1.11) 1 230 240 12.4 12.6 9 1 I/4 in. GFP 34.0 (864) 24 (610) 41 (19) 100 PF20153200 4'5 20 (1.3) 1.50 (1.11) 3 200 208 7.1 7.2 9 1 '/4 in. GFP 30.7 (780) 20 (508) 35 (16) 300 PF300511 30 (1.9) 0.50 (0.37) 1 115 120 11.8 11.8 3 1 '/4 in. GFP 21.3 (541) 20 (508) 28 (13) 300 PF300512 30 (1.9) 0.50 (0.37) 1 230 240 6.2 6.2 3 1 �/4 in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF30053200 30 (1.9) 0.50 (0.37) 3 200 208 3.6 3.6 3 1 '/4 in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF300712 30 (1.9) 0.75 (0.56) 1 230 240 8.5 8.5 5 1 '/4 in. GFP 24.8 (630) 21 (533) 29 (13) 300 PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 Y4 in. GFP 24.6 (625) 21 (533) 30 (14) 300 PF301012 4 30 (1.9) 1.00 (0.75) 1 230 240 10.4 10.4 6 1 I/4 in. GFP 27.0 (686) 22 (559) 32 (15) 100 PF30103200 4 30 (1.9) 1.00 (0.75) 3 200 208 5.8 5.8 6 1 '/4 in. GFP 26.4 (671) 22 (559) 33 (15) 300 PF301512 4' 5 30 (1.9) 1.50 (1.11) 1 230 240 12.6 12.6 8 1 Y4 in. GFP 32.8 (833) 24 (610) 40 (18) 100 PF30153200 4'5 30 (1.9) 1.50 (1.11) 3 200 208 6.9 6.9 8 1 I/4 in. GFP 29.8 (757) 22 (559) 34 (15) 300 PF301534 4'5 30 (1.9) 1.50 (1.11) 3 460 480 2.8 2.8 8 1 I/4 in. GFP 29.5 (685) 22 (559) 34 (15) 300 PF302012 5'6'7 30 (1.9) 2.00 (1.49) 1 230 240 11.0 11.0 10 1 '/4 in. SS 35.5 (902) 26 (660) 44 (20) 100 PF30203200 5, 6 30 (1.9) 2.00 (1.49) 3 200 208 9.3 9.3 10 1 Y4 in. SS 34.0 (864) 24 (610) 41 (19) 300 PF303012 5' 6, 7, 8 30 (1.9) 3.00 (2.23) 1 230 240 16.8 16.8 14 1 I/4 in. SS 44.5 (1130) 33 (838) 54 (24) 100 PF303032 5'6'8 30 (1.9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 '/4 in. SS 44.3 (1125) 27 (686) 52 (24) 300 PF305012 5'6'7'8 30 (1.9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 Y4 in. SS 66.5 (1689) 53 (1346) 82 (37) 100 PF305032 5' 6' 8 30 (1.9) 5.00 (3.73) 3 230 240 16.6 16.6 23 1 �/4 in. SS 60.8 (1544) 48 (1219) 66 (30) 300 PF30503200 5' 6' 8 30 (1.9) 5.00 (3.73) 3 200 208 18.7 18.7 23 1 '/4 in. SS 60.8 (1544) 48 (1219) 66 (30) 300 PF500511 50 (3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500512 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500532 50 (3.2) 0.50 (0.37) 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF50053200 50 (3.2) 0.50 (0.37) 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF500534 50 (3.2) 0.50 (0.37) 3 460 480 1.5 1.5 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF500712 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300 PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300 NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 2 of 6 Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com Specifications, 60 Hz (continued) Pump Model a1 a) ca o 'a c) c -ad a7 N co 7 o � = - - z > Technical Data Sheet a E lC R aa) E Length, in. (mm) Orenco® Rated cydes/day PF500734 50 (3.2) PF501012 50 (3.2) PF50103200 50 (3.2) PF501034 50 (3.2) PF5015124 50 (3.2) PF501532004 50 (3.2) PF503012 4,5,7'8 50 (3.2) PF50303200 4, 5' 8 50 (3.2) PF503034 4'5'8 50 (3.2) PF505012 5,6,7,8 50 (3.2) PF505032 5,6,7,8 50 (3.2) PF751012 75 (4.7) PF751512 75 (4.7) 0.75 (0.56) 3 460 480 1.8 1.8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 1.00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 1.50 (1.11) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100 1.50 (1.11) 3 200 208 7.0 7.0 5 2 in. SS 29.3 (744) 26 (660) 35 (16) 300 3.00 (2.23) 1 230 240 17.7 17.7 8 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100 3.00 (2.23) 3 200 208 13.1 13.1 8 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300 3.00 (2.23) 3 460 480 5.3 5.3 8 2 in. SS 40.0 (1016) 31 (787) 55 (25) 300 5.00 (3.73) 1 230 240 26.2 26.4 13 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 300 5.00 (3.73) 3 230 240 16.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 (29) 300 1.00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100 1.50 (1.11) 1 230 240 12.1 12.3 4 2 in. SS 33.4 (848) 30 (762) 44 (20) 100 Specifications, 50 Hz Pump Model PF100552 PF100752 4' 5 PF101552 5, 6 PF300552 PF300752 PF301052 PF301552 4' PF500552 PF500752 PF501052 PF501552 PF751052 10 (0.6) 10 (0.6) 10 (0.6) 30 (1.9) 30 (1.9) 30 (1.9) 30 (1.9) 50 (3.2) 50 (3.2) 50 (3.2) 50 (3.2) 75 (3.2) 0.50 (0.37) 0.75 (0.56) 1.50 (1.11) 0.50 (0.37) 0.75 (0.56) 1.00 (0.75) 1.50 (1.11) 0.50 (0.37) 0.75 (0.56) 1.00 (0.75) 1.50 (1.11) 1.00 (0.75) 220 220 220 220 220 220 220 220 220 220 220 220 230 230 230 230 230 230 230 230 230 230 230 230 3.9 6.2 10.5 4.1 6.1 7.4 9.3 4.0 6.3 7.3 9.1 7.3 4.1 6.2 11.4 4.1 6.1 7.4 9.3 4.0 6.4 7.4 9.1 7.3 6 9 18 4 5 7 8 2 3 4 5 4 1 1/4 in. GFP 1 1/4 in. GFP 1 '/4 in. SS 1 1/4 in. GFP 1 '/4 in. GFP 1 1/4 in. GFP 1 1/4 in. GFP 2 in. SS 2 in. SS 2 in. SS 2 in. SS 2 in. SS 23.0 (584) 26.8 (658) 39.5 (1003) 22.5 (572) 24.8 (630) 28.4 (721) 35.4 (899) 20.3 (516) 23.7 (602) 27.0 (686) 32.5 (826) 30.0 (762) 17 (432) 17 (432) 22 (559) 19 (483) 19 (483) 20 (508) 24 (610) 25 (635) 25 (635) 26 (660) 30 (762) 27 (686) 26 (12) 30 (14) 46 (21) 26 (12) 29 (13) 32 (15) 40 (18) 29 (13) 31 (14) 35 (16) 42 (19) 34 (15) 300 300 300 300 300 100 100 300 300 100 100 100 1 GFP = glass -filled polypropylene; SS = stainless steel. The 1 '14 -in. NPT GFP discharge is 2 7B in. octagonal across flats; the 1 /-in. NPT 2 -in. NPT SS discharge is 2 7B in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® Distributor about fittings to connect hose and valve assemblies to metric -sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, Orenco for more information. 3 Weight includes carton and 10 -ft (3-m) cord. 4 High-pressure discharge assembly required. 5 Do not use cam -lock option (Q) on discharge assembly. 6 Custom discharge assembly required for these pumps. Contact Orenco. 7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco. 8 Torque locks are available for all pumps, and are supplied with 3 -hp and 5 -hp pumps. SS discharge is 2 1B in. octagonal across flats; and the discharge hose and valve assemblies. Consult your Orenco minimum liquid level should be top of pump. Consult Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 3 of 6 Orenco® Technical Data Sheet Materials of Construction Discharge Glass -filled polypropylene or stainless steel Discharge bearing Engineered thermoplastic (PEEK) Diffusers Glass -filled PPO (Noryl GFN3) Impellers Celcon® acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3 Intake screen Polypropylene Suction connection Stainless steel Drive shaft 7/16 inch hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed motor housing ensures moisture -free windings. All thrust absorbed by Kingsbury -type thrust bearing. Rated for continuous duty. Single- phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp (1.11 kV) have built-in thermal overload protection, which trips at 203-221° F (95-105° C). Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure (total dynamic head, or TDH), providing a graphical representation of a pump's optimal performance range. Pumps perform best at their nominal flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate pump specification, use Orenco's PumpSelect software. Pump Curves, 60 Hz Models Total dynamic head (TDH) in feet 800 700 600 500 400 300 200 100 Flow in gallons per minute (gpm) Total dynamic head (TDH) in feet 160 140 120 100 80 60 40 20 PF15 Series, 60 Hz, 0.3 hp IW 13 0 3 6 9 12 15 18 21 Flow in gallons per minute (gpm) 24 NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 4 of 6 Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com 11 1 1 1 I I I PF10 Series, 60 Hz, 0.5 2.0 hp PF1020' - PF1010. PF1007 PF1005-FC ` w/'/4" flow controller 0 2 4 6 8 10 12 14 Flow in gallons per minute (gpm) Total dynamic head (TDH) in feet 160 140 120 100 80 60 40 20 PF15 Series, 60 Hz, 0.3 hp IW 13 0 3 6 9 12 15 18 21 Flow in gallons per minute (gpm) 24 NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 4 of 6 Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com 60 Hz Models (continued) 400 350 4- c 300 f=1 - 250 -a c • 200 • 150 - 100 4- Total dynamic head (TDH) in feet 50 1 1 1 1 1 1 1 -PF2015 ... •••• PF20 Series, 60 Hz, 0.5 - 1 5 hp PF2010 13F20051 ..... ..... 0 0 450 400 350 300 250 200 150 100 50 5 10 15 20 25 30 35 Flow in gallons per minute (gpm) 40 PF5050 I I I I I I I I PF50 Series, 60 Hz, 0.5 - 5.0 hp PF5030 PF5010 ..... ..... . ....... ..... ...... PF5007 ............. ..... ... PF5005 0 10 20 30 40 50 60 70 80 90 Flow in gallons per minute (gpm) Technical Data Sheet Total dynamic head (TDH) in feet Total dynamic head (TDH) in feet 900 PF3050 800 700 600 Orenco® I I I I PF30 Series, 60 Hz, 0.5 - 5.0 hp PF3030 500 400 300 200 .... PF3020 PF30151 PF3010 - I I 100 PF3005 oo 100 90 80 70 60 50 40 30 20 10 ... .......... .... ........... ........ ' • ............ .... 5 10 15 20 25 30 35 40 45 Flow in gallons per minute (gpm) jPF7515 111111 I I I PF75 Series, 60 Hz, 1.0 - 1.5 hp PF7510 oo 10 20 30 40 50 60 70 80 90 Flow in gallons per minute (gpm) 100 Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 5 of 6 Orenco° Technical Data Sheet Pump Curves, 50 Hz Models 180 Flow in gallons per minute (gpm), nominal 1.6 3.2 4.8 6.3 7.9 9.5 11 13 ■-■■■■■■-1-----3---- 160 IEU ■■■■■I•MMIMMI•=ME 140 ..111111.1.......1.11.. ■■■■■11,■■■■■■■■■■■ .E 120 MENEMOMMENNEMMEN ■■■■■■■„■■■■■■■■ 100MENEMENERNMENNE■■■■■■■■■■11,■■■■■■ s 80 ■1111®■11■■■■■■■,■■■■ foE6■■■■■'�■■■■\\■ a ra165141■11■■,■■,11■ Ta !LI 1111■■■■\ \SE\• \■■■ 20 1111■■ PF1005-FC „■■,11„■ • ■I wcontro How 1111„■■'11■ er • Immmmv■■►1■■■■ 45 40 .2 35 d E •E 30 ~ 25 as 20 E = 15 > 10 5 01 02 03 0.4 05 06 07 08 Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 7.9 16 24 32 40 48 56 63 525 _ a: 459 394 d 328 = H 262 a as = 197 131 R 66 09 PF50 Series, 50 Hz, 0.37 -1.11 kW PF501552� ,.I PF501052 PF500752� LPF500552 1 • 00 120 100 m E .E 80 as 60 a) E c 40 > Ta 20 Flow in gallons per minute (gpm), nominal 63 13 19 25 32 PF30 Series, 50 Hz, 0.37 -1.11 kW PF301552I .LPF3010521 -PF300752 00 30 131 7, 27 115 o 5 24 98 = .= 21 0 18 82 = H R 15 a 66 70 s s •—o 12 49 '= c as> 9 33 a as is o 6 16 I— 3 05 10 1.5 2.0 25 30 3.5 40 45 F ow in liters per second (L/sec) 0 0 06 1.2 18 24 30 36 42 48 54 60 Flow in liters per second (L/sec) JPF3005521 • 04 08 12 16 20 Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 10 19 29 38 48 57 67 76 86 328 = E 0 262 D 197 I- 5, m 131 'g 24 PF75 Series, 50 Hz, 0.75 kW PF751052 R 66 89 To 79 0 69 m a) 59 E = 49 I- 39 39 = 30 m 20 — a3 NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 6 of 6 Orenco Systems° Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 303 pl::Ri;.: Km; i N — puler F ofiLyGlenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT N9 1563 Owner Joe & Gerry Jarrna ron IThis does not constitute a building or use permit. System Location 3925 CO. lid. 154, Glenwood Springs 21€15-353-00—o1q Licensed installer Self * Conditional Construction approval is hereby granted for a /vet 0 gallon Septic Tank or Aerated treatment unit, Absorption area (or dispersal area) computed as follows: Perc rate of one inch in 4" minutes requires a minimum of /77 sq ft of absorption area per bedroom. ? �.. Therefore the no. of bedrooms 54-S , x /77 sq ft minimum requirement = a total of �sq fftt of absorption area. May we suggest: /2 f ` 4 Sy x I p e e 0 lr 79 'x 3Q')� fel e .e1 Date 97 -..7 inspector FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover. ing any part. t'>04c. Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground e" surface. Proper materials and assembly. a Pc Trade name of septic tank or aerated treatment unit. O`4 e.- � /000 �[i l kC 1 d /Z Adequate absorption for dispersal) area. 6� ) 3 a 1 J.. S 74e /4 L(. Adequate compliance with permit requirements. Adequate cornpliance with County and State regulations/requirements. Date Other 9, 'CONDITIONS: 1. All Installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit, 3. Any person who constructs, alters, or installs an Individual sewage disposal system in a manner which Involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 tine — 6 months in jall or both.). Inspector RETAIN WITH RECEIPT RECORD: " CONSTRUCTION SITE Applicant: Groen Copy Department: Pink Copy 1DIVIDaAL 1_)11)1��t.,r.�_ S'iS1LM Ar LICAL IJ± �'TL /WVLY /0e t f' /e a ' . p mro ©z' p rc a [ f -t_ .2.9 County Official: OWN E R QS� � y vSyLPiy1 aha f7 ADDRESS 39c' ' c,/ R�Li3> 1,‘,3/ PHONE 9.9,1<-025'.5-41 CONTRACTOR SE,j ADDRESS PHONE PERMIT REQUEST FOR: ('x) New Installation ( ) Alteration ( ) Repair Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes. (See page 4.) LOCATION OF PROPOSED FACILITY: County Ga/ -ie Near what City of Town /pyJ,o0( sp1•iLot Size Legal Description WASTES TYPE: (j() Dwelling ( ) Transient Use ( ) Commercial or Institutional ( ) Non-domestic Wastes ( ) Other - Describe BUILDING OR SERVICE TYPE: /7 Q jj% gfO mre, Number of bedrooms `3 Number of persons ( ) Garbage grinder ( ) Automatic washer ( ) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: (?{) well ( ) spring ( ) stream or creek Give depth of all wells within 180 feet of system: y If supplied by community water, give name or supplier: .� GROUND CONDITIONS: Depth to bedrock: k 10(A--, Depth to first Ground Water Table: $ /0 Percent ground slope: /24:7( DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: S'---01.11 • Was an effort made to connect to community system? A/'c2 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (7<) Septic Tank ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: ()() Absorption Trench, Bed or Pit ( ) Evapotranspiration ( ) Underground Dispersal ( ) Sand Filter ( ) Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? 7 Page 2 iL PERCOLATION TEST RESULTS: (10 be completed by Registered Professional Engineer.) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit :is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further under- stand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for per- jury as provided by law. Date ,.,2j OST PLEASE DRAW AND ACCURATE MAP TO YOUR PROPERTY Page 3 Signed PO Box 2844 Glenwood Springs, CO 81602 Ph 970.618-5033 Fax 303-216-2796 September 2, 2011 Project No. 1891 Bear Creek Construction, Attn: Bruce Upton PO Box 2324 Basalt, CO 81621 Septic Tank Design Letter 3925 County Road 154 Garfield County, Colorado Bruce, As requested, ALL SERVICE septic, LLC has prepared a septic tank design report for the subject residence. The residence and septic system are currently under construction. A 1000 -gallon, two-compartment septic tank, with an inlet tee and a BiotubeTM pump vault may be installed at the subject property to direct effluent to the existing 3 -bedroom septic system. The current septic system has been permitted by Garfield County under permit #1563. The current septic system appears to be working properly. PVC and/or concrete risers and secure lids must be installed on the septic tank, to bring access to grade. If the septic tank is placed in a driveway concrete `traffic rated' lids and risers must be used. A standard P-30 OrencoTM pump package (PV -55) and control panel is appropriate to serve septic system. The septic tank should be pumped every two to three years, and the tees inspected. If required, an effluent filter should be placed on the outlet of the septic tank. The effluent filter should be cleaned as needed. The design is based on information submitted. If conditions on site are different from conditions assumed in report, ALL SERVICE septic, LLC should be notified. All OWS construction must be according to the county regulations. Requirements not specified in this report must follow county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. This design for the subject property, noted above, is valid only in conjunction with the approved County Health Department permit. ALL SERVICE septic, LLC Timothy R. Petz Copy emailed to Bruce Reviewed By: — 96LZ'96Z'EOE xed b178Z x08 'O'd 6686 :JegwnN loeFo.id E co 01 • 0 • 0 O c — _ - F � 2 0 / 0_ o 01 — ‘,0=,0E = A :e oS 'a13Id NI`d2Ia aNv >INVI 0I1d3S `1\1011V9-000 1, ONIlSIX3 < 0 >$/-• / _ X22$ >M T G > f/ Om C =} 7 O-71 Om= m a . u $O/ \ •o = / f0 K 2/ 2 96LZ'91.Z'E0E xed 71 G) O CD CD O O V O OL2 O Cn '01 7 O1CO fn W n 0 O N C2 0 6) O N i7i79Z x08 'O'd 6686 .aagwnN }oafo.id opeaoioo `A1uno0 PlegJeD peoj Aiuno3 9z6£ llneA dwnd egnlolg 1r F4 - 3NOHd3131 4106 6LbL6 N003NO VN31-1111S 3(1N3AV AVMNIV ble ProPak'M Effluent Pumping System - PF30 pump with panel, Standard Ifo of cn co 3 cn 0