Loading...
HomeMy WebLinkAboutApplicationGarfield County tlÀ.{ 0 31$1I Commu nity Ðevelopment Ðepartment tog gth street, Suite 401 Glenwood Springs, CO 81601 fe70) 94s-8212 www. ga rf ield-countv. comi:,f.,'i'tl' ' .;,¡¡r it i' i ; trtso( BUILD¡NG PERMIT APPLICATION E Demolitiontr Commerci t] Manufactured Home or or Townhtr Residential F Du Reroof Property Oì¡rner: Mailing Address: Email Address:c-ro hb Phone: t?zot flLl 7 - S ¿/ 7 7 8/6 Phone: t?TolZL{ I - I O f8 Email Address:. Contractor: COnf tr Arpliqfa: Mailing Address: Email Address: \a t a Phone: (2zÞå"H_k-U<-g hu'.- /\)4 Phone:f ìEngineer: Mailing Address: Emaíl Address: /V14 Phone: { } ÍBOJECTg$Tâfis Manufactured Home lnstaf ler: Mailing Address: Email Address: Ðescribe Work: a T ao at- "_\I t * ? O Ie I ¡ Lot - 5ub. #of Assessor's Parcel Number: Jsb Address: Sq. Ft. of Building: I ¡ t Od O Height: Owne/s Valuation of Work: $- Block_ roperty Size (Sq. Ft. or Affes|: f Reoair tr MovelReÌocation E Detached [J Alteration El Addition a-raU Class of Work: 6arage: E New El Attached o/ PROJECT DÊTAIIS CONTINUED Septic:¡rlru r] OWTS E Natural Gas E Propane E Exempt E Cornmunity E Electric lf Permit #: Type of L Driveway r[jffi, NOTICE Authoritv. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. lf the signature below is not that of the Owner, a separate letter of authcrity, signed by the Owner, must be provided with this Applicalion. legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division. Other Permits. Mult¡ple separate permits may be required: (1) State Electrical Permit, {2) County OWïS Permit, (3) another permit required for use on the property identified above, e.g. State or County Híghway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void íf the work authorized is not commenced within 180 days of the date of issuance and if work ís suspended or abandoned for a period of 180 days after commencement. cERTtFtCåltON I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf {submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued grant¡ng permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulatlng the work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance w¡th County Regulation(s) or any other applicable law. I hereby grant permission to the Building Ðivision to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the subrnittats, if any, discov'ered after issuance; or {2) stopping construction or use of the structure(s) or fac¡lity(íes) if such is in violation of County Regulation(s) or any other applícable law. Review of this Application, including submittals, and inspections of the work by the Building Division do not const¡tute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder I hereby acknowledge that I have read and understand the Hotice and Certification above, as well ag have provided the required is correct and accurate to the best of my knowledge. s Owner Print and Sign Date Dts-4",OFFICIAT USE ONIY Specfal Conditions: L1#t¡- l-èf¿h ¡*&t-, yffivl4 -þN¿fKqzoltøò/ 2l#Ð 'Misc Fees:AaTjusted,Valuation:Plan Ch b-l Permlþe;Manuhome Fee: Total Fees: b7 8,'lo Fees Paid: v11\ffi Balance Due: O ffi;"4?tr OWTS No: N & OCC Group:R N,/Const Tvoe:-l/a'loo F Zoníng:USetbacks: BUILDING / PTANNING DIVISION : Date 5'T þ17 NOTft lf any're{uir:ed informe.tion is, rxissi¡g' delays in issuing the permit ar.e to be. expeeted. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Revieyv fee at time of application submittal. The Permit Fee, as weii as any- Road [mpact fees wil[ be coliected when the permit iå issued.. The.,per:mit Aqplication must be slgned by the owner or by a person having written authority from the owner to act as their representative. I hereby acknowle checkìibt. dge I have read, understand, and will abide with the requirements of this and Stgn'Þde, Garfield County COMMERCIAL OR MULTI.FAMILY BUILDING PERMIT APPLICATION CHECKLIST Comrnunity Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 l970l94s-8212 www. ga rf i el d-cou ntv.com CO MMERGIAL O R MULTþFAMTI-Y B U ]t Ð ING PER MIT APFI. TCAT]ON C FIECI(L ]ST ln order to understand the scope of work intended and to expedite the issuance of a permit, it is important that complete information be provided. Please,review thís document to determíne if you have adequate information to design your project and to facilitate a plan review- All applications are required to be submitted in person. APPLICATION FORM: Please make sure the following information is provided on the application. o Parcel number obtained from the County Assessor's Office. . Job address (assigned physical address). . Legal Description: block, lot, tract, subdivision, filing, or section, township and range. . Owner"s name, mailÍng address, phone, fax or cell, . Contaetors Rafile; r'nailing address, phone; fax or eell. . Architectandlor E.Rgineeris nanne,.mailing.add,r,ess, phone, fax'or'cell. . Building size, height, number of stories, lot size. . Use of building (Commercial). . Class of Work (New, Addition, Alteration, Repair, Demo, Move/ Relocation). . Detailed description of work.-. Type of heating (natur:al gas, propane, electt'ic, other)' . Sewersystem (Commtrnityor OWTS), also see other iterns below. . Garage (Attached o'r Detached)- r Driveway permit (piease see other items befow), . Valuation (labor and materials), see attached worksheet. OTHER ITEMS:r lf you anticipate obtaining a water-tap from the City of Rifle,-please provide a letter indicating that tfrê Ciiy wiii provide watei service. Ílèquired to submit buiitling permit application. . O\AITS requires a septic permit applieation to be submitted with the building permit application, r A separøte eþctllcal pefrnft mrlst bp ÞbtdlflËd fFotll lhe 8?åtp of Êolslådo Electtlcal Euard. . At the time of building permit submittal, you are required to show proof of legal and adequate access to the site. This may include proof of right to use a private easement, County Road & Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The County Road & Bridge Department can be reached at970-625-8601. '. lf you anlicipa'te excavaling or gradìng prior:to issuance of a buiNding perrnit, you wì{l be required to obtain a separate grading permit. . lf you belong to a Homeowners, Associatìon.it ìs your responsìbility'to obtaìn written aBp¡oval, if required.. Provide copies of any Resolutions and/or Land Use Permits associated with this property. . Projects with more than 10 occupants require plans sealed by a Colorado Licensed Design Professional. Occupant load shall be calculated by IBC Table 1004J. . A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups. NOTE: Any site plan depicting tle placement of any por:tion of the structure within 50 feet of a property iine or noi within an estabiished huilding envelope shall be prepared, stamped and signed by a licensed surveyor. For structures to be,built within a building envelope, provide a copy of therecorded subdivision ffnd'l itt€t wJtli ttls ÞToixlÊËd stflJcfì¡ip bnated ïh the bültdffi e-nvelÓpe. BUf LDING PLANS: 2 sets of pans must be submitted. Plans must be 18"x24" minimum siee, complete, identical, legible and to scale. Certain projects may also require a third copy of the plans be submitted to the local Fire District for review prior to permit issuance. All plans will be checked at the counter for completeness. lf any of the required information is missing, the building permit application cannot be accepted. SITE PLAN: Please make sure the following information is provid'ed on the site plan. . Property. addresslleg:al descr¡ption.¡ ñoñh Arlow dhd Scale oh each pdge. . Show all property lines, building envelopes, flood plain and easements. . Provide setback distances from boundaries, buildings, septic, well and wateruvays. . Location and direction of the county or private road and driveway accessing the property. . Proposed and existing structures. lnclude sheds, barns, decks, patios and any other buildings. r Existing and proposed grade, positive drainage around structure (to be contained on site), . Strearns,.r.ivers, Greeks, springs, ponds andditches. ' Existing and proposed wells, seplic tanks, leach fields, and othet: systems (if app'licable). . Retaining walls (engineer stamped detail required for walls over 4 ft., measured from bottom of footing to top of wall). COVER SHEET:. Projectidentification.. Froject,address andlor legal descrÎption. . Design specifications to include building use and occupancv classification, type of construction, building height and area calculations, occupant load, and fire sprinkler systerns- ARGHITECTURAL PLANS: Please provide the following information on the architectural plans. ¡ Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Design Professional stamped plans. . Minimum of 4 elevations (N,S,E,W). ' Floor,plans for each level, including dimensions and scale noted. r Cteärly tabel each room or space (office, storãge, nrechanical, etevator, eic). . Walltypes; clearly labeled and referenced. ldentify all fire resistive wall construction. . Construction details for all fire resistive elements referenced on floor plans and cross sections. lnclude wall, floor/ceiling, roof/ceiling, shaft wall assemblies and structural frame. Provide the fire resistive listing number referenced on each assembly detail. (ex. UL P123) . Window and door sizes, tyÞes and operation and direction of swing noted on'the floor plan. r Specify r,oof slope/pitch, roof covering and siding materials. . En.e:rgy design specificationsldetails for R-values, U-factor:s and SHGCIs per IECC. . Stair and guard details specifying rise, run, height and spacing. . Accessibility; show compliance with accessibility requirements for all elements of the building per lBC, Chapter 11 and ICCiANSI A 117.1, ADA, FHA, and UFAS. STRUCTURAL PLANS; Please,provid,e the following lnformatio-n'on thestructural"plans.. Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Engineer stamped plans. r Engineered foundation design per soils report. Geotechnical report referenced.r Design specifications to include roof and deck snow load, wind and seismic design and frost depth.. Foundalion plan.showing complete footing ¿¡fl foundation dimensions.. Footing and foundation detaíls specif,ying reinforcement rgferenced on plans. . Framfng plans for each fioor ievef and roof. At[beams, cofumns, joists, rafters, trusses and alf live/dead loads specified.. Framing /connection details referenced on plans. . Pre-manufactured structures require an engineer's stamp, signature and date. MECHANICAL PLANS: Please provide thefollowing information on the mechanical plans. . Per C.R.S. 12-4-112; ;$1¡uç1Lrr.s designed with an occupant load exceeding l0 require Golorado State Licensed Engineer stamped plans. . Energy design calculations and details verifying compliance with the 2009 IECC.. Floor plans for each level showing size, location and materials of all ductwork, plenums, return and outside air intake registers.. SÞe and location of all combustion air ductwork and openings.. Size. type and termination of all gas appliance flues and vents.. Location of aflfire and combinatlon smoke/fire darnpers.r Equipment schedufe for all mechanica['equípment (boiler, furnace, exhaust fans, etc.).¡ Commercial kitchen hood location, hood and duct sizes, CFM calculations. PLUMBING PLANS: Please provide the following information on the plumbing plans. . Per C.R.S. 12-4-112; Structures designed wiih an occupant ioad exceeding 10 require Colorado State Licensed Engineer stamped plans... Floorrolans for each levelshowing DWV layout and sizing, materials, slo.pe and sewer location.. Water piping materials, length and size of pipe, water meter location, fixture unit demands, location and type of backflow prevention devices.. Gas piping materials, length and size of pipe, gas meter location and BTU/hour demands.o Additional piping plans for roof/deck drains, condensate, medical gas, etc. ' PlumHng fixture schedule for all plumbing equiprnent... ''Commercial kitchen plumbing fixtures, food preparation equipment, grease interceptors, etc. ELEGTRICAL PLANS: Please provide the following informalion on the electrical plans. . Per C.R.S. 12-4-112; Structures designed with an occupant load exceeding 10 require Colorado State Licensed Engineer stamped plans. . Floor plans for each level showing location of lighting fixtures, switches, receptacles, emergency exit signs and lighting and panel location.. Diagram showing service gntrance, conduiVwire size, main disconnect size, grounding electrodelconductor size, feeder conduit/wire size, transformers and generators. . Panel schedule showing buslbreaker sizes, circuit description, voliage, phase, amperage, etc.