FIEPWORTH . FAWLAX GEÕTECIi NICAL
August 8,2008
Dave Cardiff Construction
506 Mesa Verde
Carbondale, CO 81623
APR I I 20tr
Job No. 108 4594
Subject:observation of Excavation, Proposed Residence, 2.9 miles up cattle creek
Road, Garfield County, Colorado
Dear Mr. Cardiff:
As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. observed the
excavation at the subject site on August 5, 2008 to evaluate the soils exposed for
foundation support. The findings of our observations and recom¡nendations for the
foundation design are presented in this report. The services were perfonned in
accordance rvith our agreement for professional engineering services to Dave Cardiff
Construction, dated August 5,2008.
The proposed residence will be a one story wood frame structure over fl walkout
basement. The floors of the attached garage and basement âre proposed to be slab-on-
grade. Foundations were designed based on an assumed soil bearing pressure of 4,000
psf.
At tltc time of our visit to the site, the foundation excavation lrad been cut in three levels
from I to 6 feet below tlre adjacent ground surfaee. Thc soils exposed in tlre bottorn of
the excavation consisted primarily of natural slightly sihy to clayey ¡noist gravelly sand to
silty sandy gravels and cobbles. Tlre subgrade soils in the fiost walt trend on the south
side of the house tvere moist and had sand and silt lenses within the silty sandy gravel.
Results of swell-consolidation testing performed on a sample of sand and silt taken from
the sitq shown on Figure 1, indicate the soils have low to rnoderate compressibility under
conditions of loading and wetting. The results of a gradation analysis performed on a
sarnple of silty. sandy gravels (minus 3 inch fraction) obtained liom the site are presented
on Figure 2. No free water was encountered in the excavation.
Dave Cardiff Construction
August 8,2008
Page 2
Considering the conditions exposed in the excavation and the nature of the proposed
constructioq spread footings placed on thc undisturbed natural soil designed for an
allowable soil bearing pressure of 1,500 psf should be adequate for support ofthe
proposed residence. The exposed soils tend to compress when wetted and there could be
some post-construction settlement of the foundation if the bearing soils become wet. The
amount of settlement would be related to the depth and extent ofthe settlement. Footings
should be a minimum width of I 6 inches for continuous walls and 2 feet for columns.
Loose and disturbed soils in footing areas should be removed and the bearing level
extended down to the undisturbed naturalsoils. Exterior footings should be provided
with adequate soil sover above their bea¡ing elevations for frost protection. This site
should be considered Class D ((IBC 2003) for seismic design. Continuous foundation
walls should be reinforced top and bottom to span local anomalies such as by assuming
an unsupported length of at least 12 feet. Foundation walls acting as retaining structures
should also be designed to resist a lateral earth pressure based on an equivalent fluíd unit
weight of at least 50 pcf for on-site soil as backfill. A perimeter foundation drain should
be provided to prevent temporary buildup ofhydrostatic pressure behind the basement
walls and prevent wetting oftbe lower level. An impervious membrang such as 20 mit
PVC should be provided below the drain gravel in a trough shape and attached to the
foundation wall with mastic to prevent wetting ofthe bearing soils. Structural fillplaced
within floor slab areas can consist of the on-site soils compacted to at least 95.orå of
standard Proctor density at a moisture content near optimum. Backfill placed around the
structure should be compacted and the surface graded to prevent ponding within at least
l0 feet of the building. Landscape that requires regular heavy irrígation, such as sod, and
sprinkler heads should not be located within l0 feet ofthe foundation.
The recommendations submitted in this letter are based on our observation of the soils
exposed within the foundation excavation and do not include subsurface exploration to
evaluate the subsurface conditions within the loaded depth of foundation influence. This
study is based on the assumption that soils beneath the footings have equal or better
support than those exposed. The risk of foundation movement may be greater than
indicated in this report because of possible va¡iations in the subsurface conditions. In
order to reveal the nature and extent of variations in the subsurface conditions below the
excavation, drilling would be required. lt is possible the data obtained by subsurface
exploration could change the recommendations contained in this letter. Our services do
Job No. 1084594
effiecfr
Dave Cardiff Construction
August 8,2008
Page 3
not include determining the presence, prevention or possibility of mold orother biological
contaminants (MOBC) developing ln the future. If the client is concerned about MOBC,
then a professional in this special field ofpractice should be consulted.
If you have any questions or need further assistance, please call our office.
Sincerely
HEPWORTH * PAWLAK GEOTCHNICAL, TNC.
Scott W. Richards
Roviewed by:
Ðaniel E. Hardin, P.E.
SWR/ksw
attachments Figure I * Swell * Consolidation Test Results
Figure 2 * Gradation Test Results
cc:Chris Krabacher, Architect @
JobNo.108459Â
cåStecrr
0
1
2
3
òQ
.ottt
an
o)o
Eo
CJ
4
5
6
7
I
.0 10
APPLIED PRESSURE - ksf
Moisture Content * 19.0 percent
Dry Density * 110.1 pcf
Sample of: Q¡¿yelly Silty Sand
From: Frost Walf Footing Grade, South Side
{t-t+;
7
Compres ¡þn il
uPun
wetting
il
\)
il
0.1 100
108 459A SWELL.CONSOLIDATION TEST HESULTS Figure 1
7HF
15 MrN.
TIME RÊADINGS U S. STANDARD SEFIES
#100 #50 #30 #16 #8
CTEAR SOTJAREOPENINGS
24045 4 1 #4 E8' U4' 111? 3' 5'6' 8.100
s0
80
?o
't0
20
30
c¡
240
l¡Ju
l- 50zl¡JC'
Ë,
t¡Jo-60
602
ñ
UI
o-
ı0 l-z
l¡J(Jül¡l40 o-
70
80
90
100
30
20
10
0
0ol .002 .005 ,009 .019 ,037 .A74 .150 ,300 .600 1.18 2.36
DIAMETER OF PARTCI..ES IN MII.I.IMEÌERS
4,7â 9.5 19.0 37,6
125
762 1S2 203
127
fltY fe $r,f cosstEs
GRAVEL 47 O/"SAND 26 0/"SILTAND CIAY 27 %
LICIUID LIMIT %PLASTIGnY INDEX OA
FROM:Footing Grade, West Side
+
-EE
--
--
E-
-------E ----------------
----
------
EE
-----
----
E¡-
-tI
Ë
-E
--
-
E
---
SAMPLE OF: Silty Sandy Gravet
108 459A GHADATION TEST BESULTS Figure 2
GARFIELD COU T.ITY ENVIRONITIENTAL H EALTH ÐEPA RTMENT
Percolatlon Teet and Soils Data Form - TABLE f - PROJECT {532
PROFILE PIT
0-1',
1'- 8.0'
Date of Test:
Sandy Root Zone
Sand, Clayey, Oense, Moist, Brown / Grey
Scattered Rocks up to 8-inches in diameter
No Groundwateror Bedrock was
Hole
No.
Hole
Deplh {in.)
lnterval
{min.}
Measurement at
Start of lnterval
(in.)
Measurement at
End of lnterval
{in.)
Change {in.} Percolation Rate
{min.lîn.}MPl
133 20
2A
20
20
2t
20
20
29
2A
2A
2A
20
20
20
20
20
2A
2û
2.50
4.oCI
5.00
6.00
3,50
4.50
4,00
5.00
6.r)0
7.25
4,50
5.50
r.50
1-00
1.00
1.25
1.00
1.00
fiü
2A
237 1.75
3.25
4,00
5.00
5.75
6.50
3.25
4.00
5.00
5.75
6.50
7-25
1.50
0"75
1_00
0.75
0.75
o75 27
339 2.50
4.00
s.26
6.00
7.00
7.75
4.00
5.25
6.00
7.00
7.75
dry
1.50
1.25
0.75
1.00
0.75 27
AVG = 25 lUlPl
EXHIBIT A
LAND SURVEYING@CTvlLENGINEERING
ENGINEERS ESTIMATE OF PROBABLE PUBLIC COSTS
Date: l1-10-16
RE: Velasquez Water System
Estimated improvements include:
Well pump and well pipe - $3000
Purecore piping from well house and tank 140' $30/ft. - $4200
Electrical work from house to well pump - $500
Pressure tank and switch in house - $1500
Total Estimated Cost of improvements: $9,200
Prepared by Roger Neal, PE