HomeMy WebLinkAboutApplication- PermitI DIS, F.Sy3CT� GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 Bth Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY T�t11 —��'' lj1' 1` �j Owner's NameL/i �2- Present Address 1lLldF1'I el/ I ^ � System Location Oa`I� Lorenz_ 1 Legal Description of Assessor's Parcel No. c& 3 1 aS9— - v ac:) -1 SYSTEM DESIGN Permit N° 3 8 5 7 Assessor's Parcel No. This does not constitute a building or use permit. Septic Tank Capacity (gallon) Other Percolation Rate (minutes/inch) Number of Bedrooms (or other) Required Absorption Area - See Attached Special Setback Requirements: Date Inspector FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer Septic Tank Capacity Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface Absorption Area Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/require ents Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine —6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER.' JEFF f /24A/erre (2/COL-7 ADDRESS I1/4 Incgotzi a2. RiFLF PHONE 625-2767 CONTRACTOR 6/040 /JO m FS IN C ADDRESS /1/31 ##/ZW✓Lr 120 ilfLE PHONE 60-s"2347 PERMIT REQUEST FOR ((NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town 511..--r Size of L/lt5 Lot , � C�1}G Legal Description or Address r%zl jt, A?nvD r/n) feu49' frrtEn.S ORCitna jevE1-ai. WASTES TYPE: DWELLING 006:3 1-0(EPe Z- ' ( ) TRANSIENT USE ' ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES ( ) OTHER -DESCRIBE BUILDING OR SERVICE TYPE: ,//46 Ire ricitii i N Qe-$. Number of Bedrooms Number of Persons 41 (SX) Garbage Grinder (X) Automatic Washer 04 Dishwasher SOURCE AND TYPE OF WATER SUPPLY: 00 WELL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: ? NA - Was an effort made to connect to the Community System? /10 A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: Septic Tank to Well: Leach Field to Irrigation Ditches, Stream or Water Course: Septic System (septic tank & disposal field) to Property Lines: 100 feet 50 feet 50 feet 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table Percent Ground Slope 2 1 T TE O1 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER -DESCRIBE FINAL DISPOSAL BY: ( ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER -DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: 334 Cen'l -r t'. 6704 w 64 Cfrl't s GA, a/ /1 Name, address and telephone of RPE responsible design of the system: ( T1-/ mot ro4 J r 4 CCV►ftr Drive 1660 5 C.6814, 6/ Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and famished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said appli 'on and ' . legal action for perjury as provided by law. 7710n1 56 / C Signed PLEASE ACC RATE MAP Date 94'43 YOUR PROPERTY!! 3 3C -INP0 "OA 3-0r 3 (v NNZC (+ fia 3 co' VO 1_P0P + CO h3 1 N CP S_ z <n n N r 3 Sfa 0 g ,-,I N 77+ in ▪ NXCIC» 0> pmg)n.-10 3 .+• 0 p it r. m <<Q 6- S N 3 N O ef IN -P So 0j 7p 0Q'N NN W /0 N \A -m N P P N O D. 3D NNND DW 1k_ Sip dGIE < ' NO�i)PM A A 3 n OU 3.14.c. Lla L y n N hN O<00.�� XP. PP. `FSO 3 (0 IA I l l N �,1 3 4+PK NU 1 U N e+3 -C 3"' 0'-" >�` eF O031-3 ry D hP C12- - II0 N.+`FN� _ R UI 30 110j II go N IDCI N C cop II o O2 rW -fp P < O II 0 m N. q\ p r N N .017 X \mow o_ tnN SQA IU n �+^ X n c053�< A N A3 r DW41I]nry O O II ino w N p fl - y/llh 0 Np 00 ."U Ilm xnP��i c QOp 1n Nm UI w -u N`+GIA 3 C v3 N OO. G)O3 PV ? N X .0 m •• 3 N 3 N q ry N h 9_ \ 500 Ip 4 j h Q 3 0 a a M mN 3 3 - ? n N RATIONAL & CALCULATIONS A e to 0 n C002/62/6 X3 < 2-3 171 �' 1:11< VIH W 0.13 ru V0 PI P1 r z P VIZ 3 '0 0 4.U-1 +m Q3 inn 3•< m hZ N 3 13 W C O N C3 Uf3h 0• - cf3 a hK O Q.p VI e-0 O P i PS O 3Ln n P • el - 0 O O + • VI • a P 0.0 3 VI 3 '0 3 O P P c 3 ' '0n a'0 aO' k< P n 23 P 3 3 C < '0 1< c to m m a 0 N O O .431, 3 3 h k N N 11 £'SE=.ao}o.a}puu1/•}f1bs E61E/i.tbs all 0 ;D W n r N o h o IC 3hOP DDN h < P az 0 N m 3 • DQ - m t4ND DR rro n O0 3 SZ L13 CL ID39. P m= V X 3 3 m 0 3 A at C D D 3 0 v P j1 ry 11 II imUl j mll m= pm C m V II C DO. < O 0 0 N v P (1100U a 0. s 3 X \NI1 n X 11 m -43 �m O II ems+ 0 NO m 11 •:.t o ITI V = to 0m C 3 to o a P to co- L 0 3 a fi a h 0 11 1 10:00: 01 2003 133A OS = HONI i 1314;03S 270, 73fA A Z L1 6572' 1 N-N -5NP yP-IQ N�nE0' 3hr > Ory 3NA VIrri n113i32Inin3-15 131 Np DV mthCSh00 00 h5 3 10 O -1 O p hhNhM w 1h s 3p COODq *k ) A_ry ITI .j-jh a�PO-.O OZ +OE 10 pA 6n gmS�P jN+113 rT3M30 m K 3 l Y1 N • V *11 1.7 Nh PM r 0i OKP ..a-cfrm l C 4 IA P O-�hn 3 C 3 IA - 0 Z0 /l m h IM Q1hp ii N 43 N s 33 hN 4311=r473 —<Oa3'h33P N �M 111 OQA073CN� U1p-3N h 'IC O. m p30f3DN N SS hO 10pm 10 m0 p N N h30�.1OCnOP hmi 1 s ln,- r3 SQO yr<h0 O h'0-03 jN Na+ to 0hprc S3 3 0 C -•I< /I -1 ho n''f 4+ r - hNL V f1'O ^K p a ry 0 3 Z P M I11 �1 N 3 N 73 p <ONc}3C3hm11 3nNN-O`p-V -j0 1N sh3 =IA hap hh 3 PN N -1f-I�3373C�n 'A SIA4 10 L .471;1--.+4 11 n1mm"3-313 m3=f h�SN3n 0NP = W 63 -<3NAN pnn hA 030013013 N mrFCNO4- rL -on hNoNnn FFNI N 3O3O Syp1P `hN'DN114<OQO^3ry hp3 ^��a= 'o. N P 1 CI O s h P_aSa7Z l (1 <P 11111 �P 0 3 O.� a G.ah 1 ^ p kN3 h Q. N h 3 m33hhx ml 3 AQP 7 S31ON NOIIOfa1SNO0 d c w m n n t3 D n fTl E002/62/6 70 Z7 c G1 Q.0' 3.3 7C m A otl°i r ro1 " C m -i r 0 c 1Id1JQ H31\13al N 0 3 Z UPN N 44. 3 361 (n h 3 i vZ v- A m n ram a,_,N n f1 P P 31 f1C 3 c+el- -I 3 n P 0±01045E 00.73 < 0p.+ 3 3 Z 1 a 134 0�- QSy.+ N P'nCS" 1n N 101 3 •N 4+ K 10 ,„, 3 1 MCL cv 3m5 M00,�a M 0 m 3 -7, <PA P o m ^A 3 5007 _DICV m 0 1 � 273 n '1 N N yCoP '0 CNN a n a 1 110 p 7 1 S 0 aama r Oh WO Q1 T 0 o a N 3 ti ham N S P 3 a h VI 0 P 3 3 h a 1 �_a 0 m 0 .L .-1.+ 3 a P 3 3 3 N i h13 IT P SV i N a Q' "N 3 P va,a, 3 F D13 N a n?a .--.„.-. X03 punOW Z -1 0 a Z r -a 0 .-.• v< m r 0 C 1 I= Z7 c w m n n d D I'l C002/62/6 I=1 70c a n ohamtrer m4/ W 0 3 Z V A m m y ' b 3 m H h 3 f N 4+ il N Z ellm m n r a m Z-. h a o C 3 h hoi p33 PC h0 I Oh000�-+ O p_n3 hC .f • 0.+332 1 3 a0.-..-, S3 j300mN P 41- 0j - z ME A�h".� ylmiOV O'h O m h lm 10 3`+la mO .33 Zm3v M 0CI <'Io0Z el.03p"pr _1 am o "o m o • P m m I oxv - VI 3 n ho_ mmm ,60i(vSyhj aA a_ V CNN h h m '+ a S O .+ n A m A 3-3 m 3 0 aam svi v n v ohVQv m ov • h 3 n O 33tin - a- —0 — h 3 h h m O A 3 6 P 33 mh6i 3 N0� 03 MmS m3 30h0h mnA a +h m 3- 10 a m a ✓ ,.36 mm z C A m 127 II an oa3o 3 pup 'paq uop.daosgo 'Nuo1. ;o 110 I. gaud Campbell Engiueerillg P.O. BOX 1593 Grand Junction, CO 81502 (970) 2434174 fax 243-0M gcampbel®gj.nel CERTIFICATION OF COMPLETION I hereby certify that the septic tank/ absorption bed installed at 0023 LaFeaz,Sit, CO., has been completed according to the plans and specifications and that the inctnlistion meets the requirements of the Garfield County Sewage Disposal Systems Regulations. Gary W. Campbell P.E. 0/2.0 Wd 9E'SS'E:uw1 *Wag MW OLPMEOL6LOZZOlOtenld :01 leg6Wq Aist WOJA From: Gay Curate" To: Andy -Garfield BIng.Dea. Date: 7(711004 Time: 10:33:20 PM Page 1 of 1 8 a B 'Telephone Pole 157'@315 2 way cleanout 1 2 3 4 12 11 0 4 rows of 9 each 'Equalizer 34' Chambers Scale! 1 In. = 30 ft. A Cleorlout 1250 GAL. TANK PUMPING SCH.CYRS) NUMBER OF PEOPLE 1 2 3 4 5 6 7 8 15 7.4 4.6 3.2 as 1.9 1.5 1.2 FILTER MAINTENANCE CLEAN THE FILTER LOCATED IN THE SECDID COiART1ENT OF THE SEPTIC TANK BY REMOVING IT AND SPRAYING IT WITH A HOSE DIRECTLY INTO THE SEPTIC TMK. EAI TDE THE TM& IS PIMPED. !EV FILTERS ARE AVAILABLE AT COPELMM CONCRETE RIFLE IW€NSION TABLE A-1 99.6' A-2 134.4' A-3 135.4' A-4 137' A-5 130' A-6 135' 44' `—_ gf@ tit A-8 151.6' xs>FFA-9 173' • , S A-10 1980 41 A-11 192 A-12 198' . B-1 137.5' B-2 154.5' B-3 161.6' 3-4 168.6' 3-5 169.4' 3-6 171.5' B-7 173.6' B-8 175' 3-9 246.3' 1-10 246.4' 3-11 249.4' 3-12 260.6' WARNING' Failure to pump septic tank regularly *Ill result in early absorption field failure 311360023 Laren , 30. As -Dunt NMI 1Y1 oac BATES (Annan it "gig v GEOTECHNICAL INVESTIGATION DICKEY RESIDENCE COUNTY ROAD 237 GARFIELD COUNTY, COLORADO Prepared For: JEFFERIES CONSTRUCTION 1116 Hickory Drive Rifle, CO 81650 Attention: Mr. Jeff Dickey Job No. GS -4017 August 29, 2003 CTL/THOMPSON, INC. CONSULTING ENGINEERS 234 CENTER DRIVE • GLENWOOD SPRINGS, COLORADO 81601 • (970) 945-2809 TABLE OF CONTENTS SCOPE SUMMARY OF CONCLUSIONS SITE CONDITIONS 2 PROPOSED CONSTRUCTION 2 SUBSURFACE CONDITIONS 3 SITE EARTHWORK 4 FOUNDATION 5 BELOW -GRADE CONSTRUCTION 6 SURFACE DRAINAGE 7 PERCOLATION TESTING 8 LIMITATIONS 8 FIGURE 1 -APPROXIMATE LOCATIONS OF EXPLORATORY PITS FIGURE 2 - SUMMARY LOGS OF EXPLORATORY PITS FIGURE 3 - GRADATION TEST RESULTS FIGURE 4 - EXTERIOR FOUNDATION WALL DRAIN FIGURES 5 THROUGH 7 - PERCOLATION TEST RESULTS TABLE I - SUMMARY OF LABORATORY TEST RESULTS 1 1 JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTIJT JOB NO. GS -4017 SCOPE This report presents the results of our geotechnical investigation for the proposed Dickey Residence on a parcel adjacent to County Road 237 in Garfield County, Colorado. We conducted the investigation to evaluate subsurface conditions at the site and provide foundation recommendations for the proposed construction. Our report was prepared from data developed during our field exploration, laboratory testing, engineering analysis and our experience with similar conditions. This report includes a description of the subsurface conditions found in our exploratory pits, and presents our opinions and recommendations for design criteria for recommended foundations, floor systems, and geotechnical and construction criteria for details influenced by the subsoils. The recommendations contained in this report were developed based on the currently planned construction. If plans will differ significantly from the descriptions contained herein, we should be informed so that we can check that our recommendations and design criteria are appropriate. A summary of our conclusions is presented below. SUMMARY OF CONCLUSIONS 1. Subsurface conditions encountered in our exploratory pits for the building consisted of about 6 inches of silty sand "topsoil" over 5 and 6.5 feet of slightly silty gravel and cobbles underlain by sandy clay with lenses of silty gravel to the total explored depth of 11.5 feet below existing ground surface. Free ground water was found in TP -2 at a depth of 11.5 feet at the time of excavation. The pits were backfilled immediately after excavation operations were completed. 2. We recommend constructing the Dickey Residence on footing foundations supported by the undisturbed, native gravel and clay soils. Design and construction criteria for footings are presented in the report. 3. Surface drainage should be designed to provide for rapid removal of surface water away from the proposed residence. A foundation drain should be installed around the basement. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLfT JOB NO. GS -0017 1 SITE CONDITIONS The Dickey Residence is planned on a parcel adjacent to County Road 237 in Garfield County, Colorado. The residence is planned in the central part of the property. A spring -fed pond is south of the planned residence location. Ground surface on the parcel generally slopes down to the south at grades less than 10 percent. Several natural drainages trend down to the south across the property. Natural vegetation at the site was originally pinon, juniper and sage. Most natural vegetation was grubbed and stripped during grading operations on the property. Vegetation is currently grass and weeds with scattered pinon. Harvey Gap Reservoir is located about 1 mile north of the site. The natural drainage course for water discharged from the reservoir trends south across the subject parcel. North of the subject site surface water flow from the reservoir is diverted into two irrigation ditches. Surface flow does not normally occur in the natural drainage downstream of the diversion point. Water in the pond and subsurface water at the subject site is from a combination of dam leakage and the irrigation ditches water loss. PROPOSED CONSTRUCTION The Dickey Residence will be a one-story, wood -frame building with an attached garage and a walkout basement. The basement and garage floors are planned as slabs -on -grade. Foundation loads are expected to vary between 1,000 and 3,000 pounds per lineal foot of foundation wall with maximum interior column loads of 30 kips. We anticipate maximum foundation excavation depths on the order of 5 feet deep. Fill as thick as about 4 feet will be placed to raise grades adjacent to the building. An individual sewage disposal system (ISDS) will be installed southwest of the residence. If construction will differ significantly from the descriptions above, JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTIJT JOB NO. GS -4017 2 1 we should be informed so that we can adjust our recommendations and design criteria, if necessary. SUBSURFACE CONDITIONS Subsurface conditions at the site were investigated by excavating two exploratory pits (TP -1 and TP -2) with a backhoe at the approximate locations shown on Figure 1. Excavation operations were directed by our engineering geologist who logged the soils encountered in the pits and obtained samples. Samples obtained in the field were returned to our laboratory where typical samples were selected for testing. Graphic logs of the soils encountered in our exploratory pits are shown on Figure 2. Subsurface conditions encountered in our exploratory pits for the building consisted of about 6 inches of silty sand "topsoil" over 5 and 6.5 feet of slightly silty gravel and cobbles underlain by sandy clay with lenses of silty gravel to the total explored depth of 11.5 feet below existing ground surface. Observations during excavation indicated the gravel was dense and the clay was medium stiff. Free ground water was found in TP -2 at a depth of 11.5 feet at the time of excavation. The pits were backfilled immediately after excavation operations were completed. One sample of gravel selected for gradation testing contained 79 percent cobbles and gravel, 17 percent sand, and 4 percent silt and clay size particles. Gradation test results are shown on Figure 3. Results of laboratory testing are summarized on Table I. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTUT JOB NO. GS -4017 3 1 SITE EARTHWORK Grading plans were not provided to us. We understand fill thickness of about 4 feet will be placed to attain planned grades adjacent to the building. Areas which will receive fill should be stripped of vegetation, organic soils and debris. The on- site soils free of organic matter, debris and rocks larger than 6 inches in diameter can be used as fill. Fill should be placed in thin, loose lifts of 10 inches thick or less, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor (ASTM D 698) maximum dry density. Density and moisture content of fill should be checked by a representative of our firm during placement. We anticipate excavations for the building foundation and utilities can be accomplished using conventional, heavy-duty excavation equipment. Excavation sides will need to be sloped or braced to meet local, state and federal safety regulations. We believe the sandy clay will classify as a Type B soil and the silty gravel as a Type C soil based on OSHA standards governing excavations. Temporary slopes deeper than 5 feet should be no steeper than 1 to 1 (horizontal to vertical) in Type B soils and 1.5 to 1 in Type C soils. Contractors should identify the soils encountered in the excavations and refer to OSHA standards to determine appropriate slopes. Soils removed from an excavation should not be stockpiled at the edge of the excavation. We recommend the excavated soils be placed at a distance from the top of the excavation equal to at least the depth of the excavation. Free ground water was encountered in TP -2 at a depth of 11.5 feet at the time of excavation operations. We do not anticipate excavations for foundations or utilities will penetrate ground water, however, excavations should be sloped to a gravity discharge or to a temporary sump where water can be removed by pumping. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLIT JOB NO. GS -4017 4 ig The ground surrounding the excavations should be sloped to direct runoff away from the excavation. FOUNDATION We recommend constructing the Dickey Residence on footing foundations supported by the undisturbed, native gravel and clay soils. The completed foundation excavation should be inspected by a representative of our firm prior to placing forms to confirm that subsoils are as anticipated and suitable for support of the footings as designed. We anticipate maximum total settlements on the order of 1 inch are possible for footings on the native soils with differential settlement of about 1/2 total settlement. Recommended design and construction criteria for footings are presented below. 1. The footing foundations should be supported on the undisturbed, native gravel and clay soils. Soils loosened during the excavation or forming process for the footings should be removed or the soils can be re -compacted prior to placing concrete. 2. Footings should be designed for a maximum soil bearing pressure of 2,000 psf. 3. Continuous wall footings should have a minimum width of at least 16 inches. Foundations for isolated columns should have minimum dimensions of 24 inches by 24 inches. Larger sizes may be required, depending upon foundation loads. 4. Grade beams and foundation walls should be well reinforced, top and bottom, to span undisclosed loose or soft soil pockets. We recommend reinforcement sufficient to span an unsupported distance of at least 12 feet. Reinforcement should be designed by a qualified structural engineer considering the effects of lateral loads on wall performance. 5. The soils under exterior footings should be protected from freezing. We recommend the bottom of footings be constructed at a depth of at least 36 inches below finished grades for frost protection. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLfT JOB NO. GS -0017 5 BELOW -GRADE CONSTRUCTION Foundation walls which extend below -grade should be designed for lateral earth pressures where backfill is not present to about the same extent on both sides of the wall. Many factors affect the values of the design lateral earth pressure. These factors include, but are not limited to, the type, compaction, slope and drainage of the backfill, and the rigidity of the wall against rotation and deflection. For a very rigid wall where negligible or very little deflection will occur, an "at -rest" lateral earth pressure should be used in design. For walls which can deflect or rotate 0.5 to 1 percent of wall height (depending upon the backfill types), lower "active" lateral earth pressures are appropriate. Our experience indicates typical basement walls in residences can deflect or rotate slightly under normal design loads, and that this deflection results in satisfactory wall performance. Thus, the earth pressures on the walls will likely be between the "active" and "at -rest" conditions. If the on-site soils are used as backfill, we recommend design of below -grade walls using an equivalent fluid density of at Ieast50 pcf for this site. This equivalent density does not include allowances for sloping backfill, surcharges or hydrostatic pressures. The recommended equivalent density assumes deflection; some minor cracking of walls may occur. Backfill placed adjacent to foundation wall exteriors should be free of organic matter, debris and rocks larger than 4 inches in diameter. Backfill should be moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor (ASTM D 698) maximum dry density. Water from rain, snow melt and surface irrigation of lawns and landscaping frequently flows through relatively permeable backfill placed adjacent to a residence and collects on the surface of relatively impermeable soils occurring at the bottom JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLIT JOB NO. GS -4017 6 v of the excavation. This can cause wet or moist conditions in below -grade areas after construction. To reduce the likelihood water pressure will develop outside foundation walls and reduce risk of accumulation of water in the basement, we recommend provision of a foundation drain. The drain should consist of a 4 -inch diameter, open joint or slotted pipe encased in free draining gravel. The drain should lead to a positive gravity outfall, or to a sump pit where water can be removed by pumping. A typical foundation drain detail is presented on Figure 4. SURFACE DRAINAGE Surface drainage is critical to the performance of building foundations. We recommend the following precautions be observed during construction and maintained at all times after the Jasper Residence is completed: 1. The ground surface surrounding the exterior of the residence should be sloped to drain away from the residence in all directions. We recommend providing a slope of at least 12 inches in the first 10 feet around the residence, where possible. 2. Backfill around the exterior of foundation walls should placed be in maximum 10 inch thick loose lifts, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor (ASTM D 698) maximum dry density. 3. The residence should be provided with roof gutters and downspouts. Roof downspouts and drains should discharge well beyond the limits of all backfill. Splash blocks and downspout extensions should be provided at all discharge points. 4. Landscaping should be carefully designed to minimize irrigation. Plants used near foundation walls should be limited to those with low moisture requirements; irrigated grass should not be located within 5 feet of the foundation. Sprinklers should not discharge within 5 feet of the foundation and should be directed away from the building. Irrigation should be limited to the minimum amount sufficient to maintain vegetation; the application of additional water will increase the likelihood of slab and foundation movements. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLJT JOB NO. GS -4017 7 5. Impervious plastic membranes should not be used to cover the ground surface immediately surrounding the residence. These membranes tend to trap moisture and prevent normal evaporation from occurring. Geotextile fabrics can be used to control weed growth and allow some evaporation to occur. PERCOLATION TESTING We performed percolation testing in the area of the planned individual sewage disposal system (ISDS). A profile pit (Profile) and three percolation pits (P-1 through P-3) were excavated at the approximate locations shown on Figure 1. Graphic logs of the soils encountered in the pits are shown on Figure 2. Our representative performed percolation testing in the pits on August 21, 2003. Percolation test results are presented on Figures 5 through 7. Test results indicate that the design percolation rate will be about 20 min/inch. We understand a professional engineer qualified in septic design will design the individual sewage disposal system (ISDS) for the project. LIMITATIONS Our exploratory pits were located to obtain a reasonably accurate picture of subsurface conditions. Variations in the subsurface conditions not indicated by our pits will occur. We should observe the completed foundation excavation to confirm the soils are as anticipated from our exploratory pits and suitable for support of the footings as designed. Our report was based on conditions disclosed by our exploratory pits, laboratory testing, engineering analysis and our experience. Criteria presented reflect our understanding of the proposed construction. If construction will differ significantly from the descriptions in the report, we should be informed so that we can check that our recommendations and design criteria are appropriate. JEFFERIES CONSTRUCTION DICKEY RESIDENCE CTLR JOB NO. GS -4017 8 1J This investigation was conducted in a manner consistent with that level of care and skill ordinarily exercised by geotechnical engineers currently practicing under similar conditions in the locality of this project. No other warranty, express or implied, is made. If we can be of further service in discussing the contents of this report or in the analysis of the influence of the subsoil conditions on the design of the structure, please call. CTL/THOMPSON, INC. „ J• JayesD.Kell .ggg Sta Geotech Ical Engineer JD (5 copies JEFFERIES CONSTRUCTION DICKEY RESIDENCE CM JOB NO. GS -4017 9 M V 0 • SCALE: V=100 N 1502%, 265 -II 1/37 Vic P-1 1111 TP -1 . Profile P-2 • • P-3 TP -2 • W Cit % ales Construction Dlal., Rrtlwq* Job No. GS -4017 Pi ai-o ,w 5�� rol Approximat Locations of Exploratory Pits Fig. 1 L IOP—SJ 'oN clot' 30 S901 AdYIN MnS 0 —I0 3 5 - Ea • O &• • M o a • •a ac a 3 •< -Oi' 0 3• 0 o• •eidwos ming ae+oapui 30 o a 9 e • O O o c Y • ▪ a Y ?n z Q..f a E Y a• Y •0.70Y 0 3. -0-c 0 Elevation In Feet ® IIIIIIIIIIIIIIII z 07 01 t0 CO P o N O N —I z N -4 SA N -. m H ox 4 •a•a'11or rn X3X 3V • < 3 n v c 'OOss a<o C O Q O -r O z• =p a X • wt N 3.1 ; • HYDROMETER ANALYSIS SIEVE ANALYSIS 2514t 719t. 46 MN. 15 MN. 100 90 80 I7O Y a° 50 40 30 20 10 0 .001 0.002 .019 .037 .074 .149 297 0'x190 1.19 2.0 2.38 4.76 DIAMETER OF PARTICLE IN IUJSETERS } TSE READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS 60 MN. 19 MN. 4 M. 1 MN. V00 '100 '50 '40 '30 96 '1O '8 '4 It 3/4' 115' 3' 5'6' 6' 0 912 191 361 781 10 20 30 q 40 50 60 70 80 90 1m 127 200 CLAY (MASTIC) TO SILT (NON -PLASTIC) SANDS GRAVEL FOE 1 MEDIUM 1 COARSE FINE ) COARSE I COBBLES Sample of GRAVEL, CLEAN (GP) From TP -1 AT 1-7 FEET GRAVEL 79 % SAND 17 % SILT & CLAY 4 % LIQUID LIMIT - % PLASTICITY INDEX - % HYDROMETER ANALYSIS 25 HR. 7HR. TIME READINGS 45 MN. 1SMN. 60MN.19 MN. 41111. 1 MN. 100 90 60 9 7° 60 50 40 30 20 10 0 SIEVE ANALYSIS US. STANDARD SERIES CLEAR SQUARE OPENINGS '200 900 '60 •40 30 96 '10 '8 '4 3G' 5/4' 114' 3' 5'8. 6' 0 10 20 30 40 50 BD 70 80 0.002 .019 .074 .149 297IMO 0.42 DIAMETER CF PARTICLE IN MILLIMETERS 1.19 2.0 2.38 4 76 9.62 19.1 36.1 762 90 100 127 200 152 CLAY (MASTIC) TO SILT (IAN-PIASTC) SMAS GRAVEL 1 MEDIUM I COARSE FIE I COARSE I LOBBIES Sample of From JOB NO. GS -4017 GRAVEL % SAND SILT 8 CLAY % LIQUID LIMIT PLASTICITY INDEX Gradation Test Re ults 0/0 FIG.3 SLOPE PER OSHA SLOPE PER REPORT BACKFILL (COMPOSITION AND COMPACTION PER REPORT) BELOW GRADE WALL NOTE: DRAIN SHOULD BE AT LEAST 2 INCHES BELOW BOTTOM OF FOOTING AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. ENCASE PIPE IN WASHED CONCRETE AGGREGATE (ASTM C33, NO. 57 OR NO. 67) EXTEND GRAVEL TO AT LEAST 1/2 HEIGHT OF FOOTING. COVER GRAVEL WITH FILTER FABRIC. B Job No. GS -4017 REINFORCING STEEL PER STRUCTURAL DRAWINGS PROVIDE POSITIVE SLIP JOINT BETWEEN SLAB AND WALL. FLOOR SLAB 2" MINIMUM 8" MINIMUM OR BEYOND 1:1 SLOPE FROM BOTTOM OF FOOTING. (WHICHEVER IS GREATER) 4 -INCH DIAMETER PERFORATED DRAIN PIPE. THE PIPE SHOULD BE LAID IN A TRENCH WITH A MINIMUM SLOPE OF 0.5 PERCENT. FOOTING OR PAD PROVIDE PVC SHEETING GLUED TO FOUNDATION WALL TO REDUCE MOISTURE PENETRATION Exterior Foundation Wall Drain Fig. 4 SATURATION AND PREPARATION DATE: 08/20/03 TIME AT START OF SATURATION: 5:00 pm PERCOLATION TEST DATE: 08/21/03 WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME DEPTH TO WATER CHANGE IN WATER DEPTH (INCHES) PERCOLA- TION RATE (MIN/INCH) INTERVAL (MINUTES) START OF INTERVAL (INCHES) END OF INTERVAL (INCHES) P-1 35 5:15 15 8.75 12.25 3.5 4 5:30 15 7.75 9.5 1.75 9 5:45 15 7.75 9.25 1.5 10 6:00 15 9.25 10.25 1.0 15 6:15 15 9.0 10.0 1.0 15 6:30 15 9.0 10.0 1.0 15 6:45 15 7.25 9.0 1.25 12 7:00 15 9.0 10.0 1.0 15 7:15 15 6.5 7.5 1.0 15 7:30 15 7.5 8.25 0.75 20 7:45 15 8.25 9.0 0.75 20 8:00 15 5.75 6.75 1.0 15 8:15 15 6.75 7.75 1.0 15 Job No. GS -4017 Fig 5 SATURATION AND PREPARATION DATE: 08/20/03 TIME AT START OF SATURATION: 5:00 pm PERCOLATION TEST DATE: 08/21/03 WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME INTERVAL (MINUTES) DEPTH TO WATER CHANGE IN WATER DEPTH (INCHES) PERGOLA - TION RATE (MIN/INCH) START OF INTERVAL (INCHES) END OF INTERVAL (INCHES) P-2 33 5:15 15 5.75 8.75 3.0 5 5:30 15 4.25 5.75 1.5 10 5:45 15 3.75 4.75 1.0 15 6:00 15 4.75 5.75 1.0 15 6:15 15 5.5 6.25 0.75 20 6:30 15 6.25 7.25 1.0 15 6:45 15 7.25 8.0 0.75 20 7:00 15 4.5 5.5 1.0 15 7:15 15 5.5 6.25 0.75 20 7:30 15 6.25 7.0 0.75 20 7:45 15 7.0 7.5 0.5 30 8:00 15 6.0 6.75 0.75 20 8:15 15 6.75 7.5 0.75 20 Job No. GS -4017 Fig 6 SATURATION AND PREPARATION • DATE: 08/20/03 TIME AT START OF SATURATION: 5:00 pm PERCOLATION TEST DATE: 08/21/03 WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME INTERVAL (MINUTES) DEPTH TO WATER - - CHANGE IN WATER DEPTH (INCHES) PERGOLA - TION RATE (MIN/INCH) START OF INTERVAL (INCHES) END OF INTERVAL (INCHES) P-3 37 5:15 15 4.75 8.5 3.75 4 5:30 15 4.0 6.0 2.0 8 5:45 15 6.0 7.25 1.25 12 6:00 15 4.0 5.5 1.5 10 6:15 15 5.5 6.5 1.0 15 6:30 15 5.5 6.25 0.75 20 6:45 15 6.25 7.0 0.75 20 7:00 15 5.5 6.0 1.0 15 7:15 15 6.0 6.75 0.75 20 7:30 15 6.75 7.5 0.75 20 7:45 15 5.75 6.5 0.75 20 8:00 15 6.5 7.25 0.75 20 8:15 15 4.5 5.5 1.0 15 Job No. GS -4017 Fig 7