HomeMy WebLinkAbout1.33 EngDesign-EngineeringDesignReportCOLORADO PROJECT ENGINEERING DESIGN REPORT RIVER EDGE COLORADO GARFIELD COUNTY, COLORADO OWNER/APPLICANT: CARBONDALE INVESTMENTS, LLC 7999 HWY 82 CARBONDALE CO 8 1 6 2 3 970-456-5325 CONSULTANT: 8140 PARTNERS, LLC PO BOX 0426 EAGLE, CO 81631 JANUARY 14, 2010 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado PROJECT ENGINEERING DESIGN REPORT RIVER EDGE COLORADO GARFIELD COUNTY, COLORADO TABLE OF CONTENTS INTRODUCTION 3 A. BASIS 3 B. PURPOSE AND SCOPE OF REPORT 3 C. LIMITATION AND RESTRICTIONS ASSOCIATED WITH PRELIMINARY ENGINEERING 3 D. FINDINGS 4 II. DESIGN STANDARDS AND CRITERIA 4 III. PROJECT LOCATION AND DESCRIPTION 5 A. PROJECT LOCATION 5 B. PROJECT DESCRIPTION 5 IV. DESIGN AND CONSTRUCTION APPROACH 6 1. SITE RECLAMATION 7 2. ROADS 8 3. WATER AND WASTEWATER 10 4. DRY UTILITIES 10 5. EROSION AND SEDIMENT CONTROL 11 APPENDICES APPENDIX A: VICINITY MAP AND PROJECT SITE DRAWINGS APPENDIX B: WILL SERVE LETTERS APPENDIX C: STORM SEWER, INLET AND CULVERT SIZING 2 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado I. INTRODUCTION A. BASIS This Project Engineering Design Report ("Report") has been prepared in support of an application for PUD Plan Review ("Rezoning") and Subdivision Review ("Preliminary Plan") for the proposed River Edge Colorado ("Project", "REC", or "REC PUD") in accordance with the requirements of the Garfield County Unified Land Use Resolution of 2008 ("ULUR"), as amended. This Report is submitted in support of the overall project engineering plans required under Sections 5-501.G.11, 6-301.6.4, and 6-301.6.5.e of the ULUR. This Report provides support to the other referenced documents submitted as part of the REC rezoning and preliminary plan applications including the engineering reports and plans covering water and wastewater systems, hazard mitigation, erosion and sediment control, and hazard mitigation; and the River Edge Colorado PUD and Subdivision Drawing Package ("Drawing Package"). B. PURPOSE AND SCOPE OF REPORT The purpose of this Report is to present the engineering framework associated with the preliminary engineering plans (Series C00-07, DR01-03, S01, B01, and SW01-07 along with ES01-05 and CP01 of the Drawing Package). The intent of the preliminary engineering plans is to meet the County's requirements as expressed in Article V and VI of the ULUR, and provide adequate evidence that the design meets or exceeds applicable standards as expressed in Article VII of the ULUR. This Report discusses those elements associated with the design and coordination of infrastructure components not otherwise specifically dealt with under other more specific engineering reports submitted as part of the REC rezoning and preliminary plan application package including: • Reclamation Plan; • Water Supply Plan; • Water Treatment and Distribution System Design Report; • Sanitary Sewage Disposal Plan; • Sewage Collection Design Report; • Hazard Mitigation Plan; • Erosion and Sediment Control Plan; and • Drawing Package. C. LIMITATION AND RESTRICTIONS ASSOCIATED WITH PRELIMINARY ENGINEERING The plans and reports presented are designed to support the REC rezoning and preliminary plan review and approval process based on the requirements of ULUR. The 3 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado plans and reports present the overall design intent, layout, facilities coordination, and operational configurations for the Project based on Garfield County, appropriate agency, and industry standards. The plans and reports are intended to show practicability and support final design, which final design will generally conform to these plans and reports, if the REC rezoning and preliminary plans are approved. The plans and reports are not intended to provide the design information necessary to support the permitting or approval processes of other agencies. D. FINDINGS Series C00-06, DR01-03, S01, B01-02, and SW01-07 along with ES01-05 and CP01 of the Drawing Package and the associated plans and reports were prepared by or under the direction of a registered professional engineer (William S. Otero, State of Colorado Professional Engineer, Registration #32163). The content of the drawings, plans and reports provide evidence that the Project conforms to the ULUR in all respects except those standards and criteria from which a modification is specifically requested as part of the REC rezoning and preliminary plan applications. The request for modifications are detailed and justified in the Rezoning and Subdivision Justification Report. II. DESIGN STANDARDS AND CRITERIA The following standards and criteria were used in preparing the drawings, plans and reports: • ULUR; • 2003 International Fire Code (as amended by Garfield County); • 2009 International Building Code (as amended by Garfield County); • Roaring Fork Water and Sanitation District Rules and Regulations, dated 2007 ("RFWSD Rules"); • Site Location and Design Approval Regulations for Domestic Wastewater Treatment Works 5 -CCR 1002-22, CDPHE Water Quality Control Commission ("WQCC") dated September 30, 2009 ("CDPHE Site Location and Design Approval Regulation"); • Design Criteria for Potable Water Systems, CDPHE Water Quality Control Division ("WQCD") dated March 31, 1997 ("CDPHE Design Standards"); • Colorado Primary Drinking Water Regulations 5 CCR 1003-1, CDPHE Water Quality Control Commission ("WQCC") dated August 9, 2010. ("CDPHE Drinking Water Standards"); • New Water System Capacity Planning Manual, CDPHE WQCC ("CDPHE Planning Manual"); 4 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado • Guide for Determination of Needed Fire Flow, Insurance Services Office ("ISO"), 2008; • Urban Storm Drainage Criteria Manual ("USDCM") dated June 2001, Urban Drainage and Flood Control District ("UDFCD"), Denver, Colorado; • Colorado Floodplain and Stormwater Criteria Manual, dated 2006, Colorado Water Conservation Board; • A Policy on Geometric Design of Highways and Streets, dated 2004, American Associated of State Highway and Transportation Officials ("AASHTO"); • 1998 State Highway Access Code, dated March 2002, Colorado Department of Transportation; • Engineering Criteria Manual, dated July 1, 2010, Transportation Engineering, City of Colorado Springs; • Neo -Traditional Street Design, dated 1995, Institute of Transportation Engineers; and • Roundabout Design Standards: A Section of the Traffic Engineering Policy & Design Standards, dated October 4, 2005, Transportation Engineering, City of Colorado Springs. In addition, where certain necessary standards and criteria were not included as part of the local standards or where standards were not applicable due to site conditions or the proposed development program, state and federal codes and statewide or nationwide standards were utilized as an alternative. Where such state and federal standards and criteria specifically conflict with an applicable ULUR standard or criteria, modifications have been requested as part of the REC rezoning and preliminary plan application and are included as a part of the Rezoning and Subdivision Justification Report. III. PROJECT LOCATION AND DESCRIPTION A. PROJECT LOCATION The Project is located along State Highway 82 ("SH 82") between the City of Glenwood Springs and Town of Carbondale near the junction of County Road 110/113 ("CR 113") and SH 82. The property is located almost entirely west of the Roaring Fork Transit Authority ("RFTA") right-of-way and east of the Roaring Fork River and the Roaring Fork Conservancy ("RFC") Conservation Easement (i.e., Grant of Conservation Easement dated February 3, 2000, recorded at Reception Number 559036 and survey map, recorded December 24th, 2008, recorded at Reception Number 760571 in the real property records of Garfield County, Colorado). The Project straddles Cattle Creek which is also located within the RFC Conservation Easement. A vicinity map is provided as Exhibit 1 in Appendix A. The Project covers approximately 160 acres ("Project Site") as 5 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado shown and described on the Project Site drawing [Exhibit 2(a -d), Appendix A]. The Project is proposed by Carbondale Investments, LLC ("CI"). B. PROJECT DESCRIPTION The Project is a proposal to create a walkable clustered -form of residential development with neighborhood amenities including naturalized open space and enhanced wildlife habitat, community recreation, parks, and neighborhood agriculture that is designed to serve the residents and preserve and provide reference to the rural character and agricultural roots of the Roaring Fork Valley. The Project aims to have a strong historic identity back to the days of 'old Colorado' when compact neighborhoods formed with a strong sense of community based on the land and surrounding landscape. The REC landscape aesthetic will be simple, informal, and place emphasis in the use of plant and landscape materials local, adaptable and appropriate to the climate and environment of the area. The Project will include approximately 366 residential units of various sizes and types including 55 affordable homes and one exclusive executive lot for a custom home. Housing types will range from attached homes to small single family attached and detached garden homes, village homes, and larger estate homes. Smaller garden homes are anticipated to be designed for younger residents that are looking for their first home in the County, while village homes and estate homes will provide move up opportunities for growing families. Densities in the Project are proposed at less than 2% units per acre. Lot sizes will vary from over 1 acre to approximately 5,000 square feet for single family homes, and 1,700-5000 square feet of lot area for each garden home. Most of the units back to either proposed active parks or reclaimed open space to help enhance the connection to the land. The REC layout and design is depicted in the PUD Plan, PUD01-03 Series and the Preliminary Plan PRPN01-03 Series of the Drawing Package. The architectural theme will be complementary to the traditional architecture of the valley. Generally, exterior materials will include wood, stone, brick, stucco and cement board siding. Varied roof heights and articulation of the front elevations will be used to break up the massing and provide street -level appeal. Front porches and covered stoops are included on homes to emphasize the entry and connection to the sidewalk and street. Roofing will include dimensional shingles, metal, or other materials appropriate to the building style and that roofs will generally be pitched. Gables, wall plane and roofline articulation, bays, balconies, porches, canopies and arcades will be used in the design of various buildings. The selection of materials will minimize the exterior maintenance of the homes to help maintain a quality appearance for the long term. The street pattern and pedestrian network are designed to facilitate community interaction. Streets have detached sidewalks with designated cross walks at major intersections and landscaped areas that create a comfortable environment for walking. On -street parking in most areas will further buffer vehicular and pedestrian uses. Internal circulation is maximized and dead-end streets are limited. Alleys are used where appropriate to enhance the streetscape and achieve a mix of housing styles. A soft trail system is used to connect open spaces and other common elements with the sidewalk network. The homes are placed close to the streets to help define the 6 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado streetscape space and provide visual interest to pedestrians. Street trees and plantings are proposed to enhance the aesthetics of the street. The community is served with a variety of recreational facilities and a neighborhood center that could include meeting room(s), fitness room, offices, kitchen, restrooms, recreational facilities, and limited community service use such as a day care facility, deli/coffee shop, or health club. Parks will provide informal recreational opportunities within the community and will likely include tot lots, playfields, and trail system. The west portion of the property is generally set aside as the naturalized area that buffers the RFC Conservation Easement along the Roaring Fork River. The soft trails around the property allow residents to enjoy the river and wetland areas without disrupting the environment in conformance with the terms of the RFC Conservation Easement. More than the minimum open space requirements will be met by the project. Nearly 50% of the Project Site is in some form of open space, common area or park. Finally, opportunities for productive and edible landscapes, including community gardens and neighborhood orchards are integrated and dispersed in between the residential land uses as gathering and focal places for residents connecting REC to its agricultural heritage. The combination of trails, recreation areas, and open space system with the ability to engage in 'interactive community agriculture' on a small scale will make REC a very desirable place to live, filling a unique niche not yet met in Garfield County. This unique combination will help establish a sense of place, foster community, and engage residents with their immediate environment. It is intended this overall outdoor focus will set the tone and become a major driver of the identity of REC. IV. DESCRIPTION OF DESIGN AND CONSTRUCTION 1. SITE RECLAMATION (PHASE 0) Past development efforts that were prematurely terminated left the overall Project Site in poor condition as a result of extensive grading including substantial cut and fill areas and the removal of protective surface soils. Prior to initiating development activities, the Project Site must be reclaimed in order to address a variety of issues resulting from the degradation and land form changes associated with such previous activities. The Reclamation Plan (Appendix U of the Impact Report) details the proposed pre -development reclamation activates proposed for the Project Site that would be under taken as Phase 0 in advance of development construction. These activities are shown on the Series RPO1 of the Drawing Package and the post -reclamation conditions are shown on the Series ES02 of the Drawing Package. Where development - related actions are most appropriately taken at the time of reclamation and would result in limiting site disturbance and habitat impacts or alleviating safety issues and concerns, these actions are included in the proposed reclamation actions. Although site reclamation is proposed as a pre -development action, the development plans and drawings are based on existing conditions and not on Project Engineering Design Report River Edge Colorado, Garfield County, Colorado post -reclamation conditions. Final design must be coordinated with the post - reclamation conditions once these actions are completed. 2. ROADS Roads internal to the site were planned as continuous streets to provide for vehicular movement and facilitate mobility for other modes of travel with attached sidewalks and bike friendly speeds and sections. The residential areas are "clustered" with urban densities. Therefore, the standards used for street design were built based on the standards and framework provided by existing Garfield County road design standards contained in Section 7-307 of the ULUR, but were modified to meet Project objectives utilizing urban road design standards from several municipal jurisdictions in Colorado (i.e., most specially the City of Colorado Springs but also included a review of design standards in the City of Fort Collins and City of Denver), AASHTO and Neo -Traditional Street Design. The street sections adopted for use at REC are on shown on Typical Street and Trail Sections, C04 Series of the Drawing Package. The design criteria used for street layouts (Street Plan and Profiles, CO2 Series of the Drawing Package) are as presented in Table 1. The criteria are well within other jurisdictional standards for comparable development plans and meet the needs of the Carbondale Fire Protection District. In addition to vehicular movement, all the streets provide for on -street parking and detached sidewalks except alleys and courts. Table 1: Street Design Criteria Criteria Entry Road Local Alley / Court Garden Home Access Emergency Vehicle Access (EVA) Design Capacity (ADT) 8,000 5,000 <500 <500 n/a Design Speed (mph) 25 25 n/a n/a n/a Posted Speed (mph) 25 25 n/a n/a n/a Pavement Width (Lanes) 24 (2)1 36 (2)2 24 (2)3 20 (2)4 20 Min. Horizontal Radius (ft) 185 80 50 50 n/a Design Vehicle WB -50 WB -40 n/a n/a n/a Curb Return Radii (ft) 30 20 n/a n/a n/a Max. Grade (%) 8 8 8 8 8 Cross Slope (%) 2 2 2 n/a n/a Surface Asphalt Asphalt Asphalt Asphalt Asphalt 1 Two 12' travel lanes plus raised median (varying width) and no on -street parking. 2 Two 10' travel lanes and on -street parking on both sides of the street. 3Two 10' travel lanes and 2' shoulders. 4 Two 10' travel lanes. The street hierarchy for the planned development consists primarily of two sections, Local and Alleys/Courts. Local streets provide site -wide mobility for homeowners and guests at a capacity that will exceed 5,000 vpd. The Local road 8 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado section also allows for on -street parking on both sides of the street throughout all neighborhoods and direct access to all front loaded residential lots (driveway spacing is approximately 50 feet). Drainage will be controlled through the use of curb and gutters which direct flows toward storm sewer inlets. The Local street section was selected based on the planned character of the neighborhoods and level of safety expected for those using the street or interacting with it from the adjoining lots. Examples of similar urban streets can be found in Eagle Ranch, Town of Eagle, Eagle County, Colorado. Alleys/ Courts provide short connections between Local streets and access to rear loaded residential lots and garden homes (driveway spacing of less than 40 feet). The required minimum width of pavement for the Alleys/Courts sections is 20 feet per discussions with the Carbondale Fire Protection District. The Alleys/Courts section provides for 24 feet of pavement, Drainage will be controlled through the use of cross pans which direct flows toward the adjoining Local streets or adjacent drainageways. All lots directly access private streets that then access SH 82 via the main entrance at Cattle Creek Road. In addition to these two primary street sections, the entry road (River Edge Drive) is the approximately 500 foot street segment from the main access off SH 82 to the roundabout. The street section associated with this segment of road is adjusted throughout its length so as to coordinate with the highway access, RFTA right-of-way crossing, entrance to the neighborhood center and proper entry the roundabout. Detailed coordination on the entry road with CDOT and RFTA will be necessary during the final design process to ensure the design requirements of each agency are met Based on discussions with CDOT, it is anticipated that CDOT review will be threefold in accordance with the State Access Code. First, CI was required to complete a traffic assessment per requirements of Garfield County. Second, CI will be required to develop near and long term concepts to be used in discussions with affected agencies and land owners. Third, CI will be required to prepare a Level III Traffic Impact Report and final intersection design to support application for a CDOT Access Permit. In addition to the main access, two Emergency Vehicle Access (EVA) points have been discussed with CDOT, RFTA, and Carbondale Fire Protection District. The EVAs will be access - controlled to only allow for access during an emergency, no other access at these locations will be permitted. A roundabout is proposed at the main intersection internal to the development as a means of best accommodating traffic from the northern and southern areas of the Project. The roundabout is designed in accordance with standards from the City of Colorado Springs. The capacity for the roundabout will exceed 20,000 vehicles per day (vpd), with a peak hour capacity of 1,500. The preliminary design is provided on Roundabout Layout, CO3 Series of the Drawing Package. The preliminary design associated with road network is presented on the supporting drawings (Series C01 - C07 of the Drawing Package), 9 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado 3. WATER AND WASTEWATER Onsite water and wastewater utilities are designed to support the planned development while considering future growth within the area outside Project. The overall layout of utilities generally mirrors the horizontal alignments of the streets. However, where appropriate the utility network was placed in easements outside paved street sections to create a more efficient and cost effective system. The RFWSD Rules and Regulations dated February 2007 were utilized as the primary source for design standards and criteria. The primary objective of the preliminary design was to consider the RFWSD standards in relationship to the site conditions and the planned development. In a vast majority of the situations the RFWSD standards can be met. However, there may be limited instances where the density of the "clustered" development may result in the need to vary from the RFWSD standards to achieve the design objectives. In these instances, the alternative standards will be coordinated with RFWSD to ensure the primary objectives for the water and wastewater systems are met. Based on the preliminary design, the only RFWSD standard not currently met was the minimum depth of flow within the sanitary sewer lines (i.e., 50 percent at peak flows). The minimum sanitary sewer line flow depth standard utilized by the RFWSD is somewhat unusual. The typical standard for depth of flow in pipes is focused on a maximum flow depth targeted at making sure the pipe is not pushed beyond its capacity when reaching peak flows. Therefore, the standard would typically be written as a maximum 50 -percent full during average flows and a maximum 80 -percent full during peak flows. Under the proposed standards, the system as planned will achieve the alternative standard of flow depth at the slopes, velocities, and pipe sizes presented. The preliminary design associated with water supply, treatment and distributions and sewage collection and disposal are described in detail in the Sewage Collection Report, Water Treatment and Distribution Design Report, Water Supply Plan and Sanitary Sewage Disposal Plan and supporting drawings (Series SW01 - SW04 of the Drawing Package). In addition to the planned water and sewage systems described above, the Project will provide raw water irrigation. The raw water will come from the Glenwood Ditch and be piped across the site via a community -owned and operated distribution system. This system is required under the water rights adjudications which will provide potable water. The Raw Water Supply and Distribution Plan and supporting drawings (Series SW05 of the Drawing Package) detail the preliminary design of the raw water system. 4. DRY UTILITIES Dry utility service provided by regional providers was also considered during the development of the preliminary design. Accessible and coordinated corridors for installation of these services have been planned for in the design and each 10 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado provider has provided a "will serve" letter (Appendix B). Easements are provided along lot lines. Utilities are also accommodated in Right -of -Way Tracts 5. EROSION AND SEDIMENT CONTROL Under the Garfield County ULUR, the Erosion and Sediment Control Plan ("ESCP") is an all encompassing plan supporting grading, drainage, and surface water quality requirements. As such, the ESCP documents existing, reclaimed, phased and final conditions of the Project. In addition, the ESCP supports other plans such as the Reclamation Plan and the Hazard Mitigation Plan by defining how surface water is managed throughout the entire development process. As presented in the ESCP, the surface water quality and quantity is managed two ways utilizing the criteria from the USDCM. First, the runoff created by the development is limited by the design (i.e. reduced areas of imperviousness) and conveyed directly offsite to either Cattle Creek or the Roaring Fork River. Second, the "first flush" of surface water, which typically contains the highest concentration of contaminants, is treated via vegetated channels or through capture in one of three "water quality" ponds. No detention of storm water quantity volumes is proposed. The direct release of runoff from the Project Site without detention is discussed in detail in the ESCP. However, the two primary reasons behind this requested modification are that: (1) the site is low in the basin therefore releasing the runoff from the Project Site prior to the peak flows from other contributing basins upstream likely better limits the magnitude of the peak runoff condition downstream of the Project Site; (2) the direct release has no affect on any downstream properties or existing stormwater facilities. The preliminary design associated with the Erosion and Sediment Control Plan are detailed in the related report and supporting drawings (Series ES01 - ES05 of the Drawing Package). 6. DRAINAGE STRUCTURES Culverts and storm sewer were preliminarily located and culverts sized for the entire Project Site based on the overall drainage needs and design intent. The goal for stormwater management for the Project is to minimize storm water conveyance via piping and utilize open space areas to collect and convey storm water. Therefore, inlets located in road will immediately discharge to swales located in adjacent open space on much of the site. This approach provides two benefits. Discharging to grass swales will provide enhanced water quality prior to discharge to receiving waters (i.e. Cattle Creek and Roaring Fork River), and utilization of grass swales will provide increased travel time relative to conveyance via storm sewer pipe which servers to decrease peak flows and potentially reduces the size of major conveyance features. However there are three locations where it is anticipated that storm sewer will be needed due to the Project design constraints. 11 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado For preliminary analysis, storm sewers were sized and designed in three locations. There is one storm sewer system on the north portion of the Project and two on the south. The northern system captures the main drainage channel that drains much of the north portion of the project (Basin P2) as well as the offsite basin to the east (Basin OS -1) and discharges to Pond NP2. Therefore, a more detailed preliminary analysis was conducted on this system to ensure the system could accommodate the anticipated flows. A conservative 100 -year return period storm was used and the results of this analysis are shown in Appendix C. A more basic analysis was conducted for the other two systems as these are minor in nature. The Riverside Loop Drive system has a capacity of 100 cfs and an anticipated 100 -year flow of 12 cfs. The Alpine Bluff Street system has a capacity of 100 cfs and an anticipated 100 -year flow of 20 cfs. A preliminary layout of all these systems can be found in Series DR01-03 of the Drawing Package. Preliminary calculations for culvert sizing were also completed along all drainage channels and can be found in Appendix C. Preliminary sizing of the culverts was done in accordance with the USDCM methodology. The stage -discharge relationship and entrance and exit head loss given the configuration of the culvert are provided. For each stage, a maximum flow rate for both inlet control and outlet control is calculated. A manning's "n" of 0.013 was used for all culverts. Slopes were estimated based on the current over -lot grading plan and minimum cover was assumed to be 18 -inches when underneath a road. Material for all culverts is preliminarily proposed as concrete and pipe class will be determined at final design based on estimated loading. Proposed culvert locations are shown on the Drainage Structures Plan and Profiles, DR02 Series of the Drawing Package. 12 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado APPENDIX A: VICINITY MAP AND PROJECT SITE DRAWINGS App. B-1 BITS\MISC REPOPT FIGURES \PUD-VICMAP.DWG N m > o a Eo `w= CLj 3 Q 0H 0 0 0 0 0 N 5 000 0 5.000 10 000 SCALE IN FEET Owner/Developer: RiVentige COLORADO Carbondale Investments, LLC 7999 HWY 82 Carbondale, CO 81623 Phone No: 970.456.5325 Title: VICINITY MAP Prepared by: 8140 Partners, LLC Date: 12/01/10 Exhibit: App. B-2 BITS \MISC REPORT FIGURES \PUD -L 02 PRELIM PLAT\ENGINEERING & DESIGN \CAE 06.00 DESIGN TASKS \06.0 LEGAL DESCRIPTION - PARCEL A (NORTH PARCEL) - RIVERS EDGE PUD A TRACT OF LAND SITUATED IN THE EAST HALF OF SECTION 12, TOWNSHIP 7 SOUTH, RANGE 89 WEST, AND IN THE WEST HALF OF SECTION 7, TOWNSHIP 7 SOUTH, RANGE 88 WEST OF THE 6TH PRINCIPAL MERIDIAN, COUNTY OF GARFIELD, STATE OF COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING GARFIELD COUNTY SURVEYOR'S 2 1/2" BRASS, FOUND IN PLACE, AND CORRECTLY MARKED A5 THE SOUTHEAST CORNER OF SAID 5E01104 7, THENCE S 4022'15" E A DISTANCE OF 5479.54 FEET TO THE TRUE POINT OF BEGINNING; THENCE, 5 8043'30" E A DISTANCE OF 100544 FEET TO A POINT ON THE WESTERLY LINE OF THE ROARING FORK TRANSIT AUTHORITY TRANSPORTATION CORRIDOR EASEMENT; THENCE, ALONG THE WESTERLY LINE OF SAID EASEMENT S 103052" E A DISTANCE OF 2644.53 FEET; THENCE, 494.34 FEET ALONG THE ARC OF A CURVE TO THE RIGHT, HAVING A RADIUS OF 2815.00 FEET, A CENTRAL ANGLE OF 10'03'42 AND SUBTENDING A CHORD BEARING OF S 145701" E A DISTANCE OF 493.70 FEET, THENCE, 5 203559" E A DISTANCE OF 120.78 FEET; THENCE, DEPARTING THE WESTERLY LINE OF SAID EASEMENT N 663814" W A DISTANCE OF 6045 FEET; THENCE, N 49'54'10" W A DISTANCE OF 64.72 FEET; THENCE, N 4054'10" W A DISTANCE OF 86.97 FEET; THENCE, N 4811'10" W A DISTANCE OF 54.30 FEET; THENCE, N 5647'27" W A DISTANCE OF 123.97 FEET; THENCE N 8747'24" W A DISTANCE OF 93.00 FEET; THENCE, N 273511" W A DISTANCE OF 119.58 FEET; THENCE, N 78'00'43" W A DISTANCE OF 33.84 FEET; THENCE, S 79'41'48" W A DISTANCE OF 37.80 FEET, THENCE, S 22'57'521 W A DISTANCE OF 56.05 FEET; THENCE, 5 59'3157" W A DISTANCE OF 4548 FEET; THENCE, N 8732'35" W A DISTANCE OF 28.23 FEET; THENCE, N 500703" W A DISTANCE OF 95.71 FEET, THENCE, N 71'20'44" W A DISTANCE OF 85.73 FEET; THENCE, N 3843'10" W A DISTANCE OF 93.22 FEET; THENCE, N 25'39'22" W A DISTANCE OF 181.92 FEET, THENCE, N 6610'24" W A DISTANCE OF 98.43 FEET; THENCE, 5 85'02'33" W A DISTANCE OF 52.20 FEET; THENCE, S 563752" W A DISTANCE OF 39.34 FEET; THENCE, S 2749'33" W A DISTANCE OF 42.96 FEET; THENCE, S 37'27'43" E A DISTANCE OF 21.60 FEET; THENCE, N 7T02'57" W A DISTANCE OF 89.66 FEET; THENCE, S 70'24'18" W A DISTANCE OF 70.95 FEET; THENCE, N 88'59'39" W A DISTANCE OF 55.55 FEET; THENCE, 5 84'28'58" W A DISTANCE OF 49.93 FEET; THENCE, N 1422'48" E A DISTANCE OF 68.20 FEET; THENCE, N 05'11'46" W A DISTANCE OF 77.59 FEET, THENCE, N 18'20'05" E A DISTANCE OF 10,82 FEET; THENCE, N 225740" E A DISTANCE OF 44.14 FEET; THENCE N 10'34'58" E A DISTANCE OF 35,11 FEET; THENCE, N 08'59'51" E A DISTANCE OF 47.16 FEET; THENCE, N 03'48'08" E A DISTANCE OF 36.48 FEET; THENCE, N 04'4052" E A DISTANCE OF 71.03 FEET; THENCE, N 0737'51" E A DISTANCE OF 5466 FEET; THENCE, N 2028'14" W A DISTANCE OF 63.68 FEET; THENCE, N 3250'44" W A DISTANCE OF 61.05 FEET; THENCE, N 261759" W A DISTANCE OF 55,52 FEET; THENCE, N 38'14'36" W A DISTANCE OF 44.36 FEET; THENCE, N 53'11'32" W A DISTANCE OE 37.73 FEET; THENCE, N 59'54'48" W A DISTANCE OF 54.16 FEET; THENCE, N 8751'35" W A DISTANCE OF 36.97 FEET; THENCE, N 57'33'47" W A DISTANCE OF 65.70 FEET; THENCE, N 81'56'22' W A DISTANCE OF 8502 FEET; THENCE, N 04'11'29" W A DISTANCE OF 158,65 FEET; THENCE, N 355741" W A DISTANCE OF 41.30 FEET; THENCE, N 544803" W A DISTANCE OF 2470 FEET; THENCE, N 2651'45" W A DISTANCE OF 20999 FEET; THENCE, N 11'58'37" W A DISTANCE OF 3382 FEET; THENCE, N 415746" E A DISTANCE OF 78.19 FEET; THENCE, N 062701" W A DISTANCE OF 117.20 FEET; THENCE, N 270627" W A DISTANCE OF 94.24 FEET; THENCE, N 11'3253" W A DISTANCE OF 63.83 FEET; THENCE, N 07157'46" W A DISTANCE OF 141.45 FEET; THENCE, N 005814" E A DISTANCE OF 50,76 FEET; THENCE, N 1017'44" W A DISTANCE OF 91.04 FEET; THENCE, N 44'4159" W A DISTANCE OF 134.55 FEET; THENCE, N 102749" W A DISTANCE OF 7418 FEET; THENCE, N 19'33'06" W A DISTANCE OF 43.27 FEET; THENCE, N 21'30'01" W A DISTANCE OF 72.23 FEET; THENCE, N 00'1830" E A DISTANCE OF 217.77 FEET; THENCE, N 00'1650" E A DISTANCE OF 312.94 FEET TO THE POINT OF BEGINNING, CONTAINING AN AREA OF 73.003 ACRES, MORE OR LESS. THE NAME AND ADDRESS OF THE PERSON WHO CREATED THIS LEGAL DESCRIPTION IS: JEFFREY ALLEN TUTTLE, P.LS. 33638 727 BLAKE AVENUE GLENWOOD SPRINGS, COLORADO 81601 LEGAL DESCRIPTION - PARCEL C (SOUTHEAST PARCEL) - RIVERS EDGE PUD A TRACT OF LAND SITUATED IN THE SOUTHWEST QUARTER OF SECTION 7, TOWNSHIP 7 SOUTH, RANGE 88 WEST OF THE SIXTH PRINCIPAL MERIDIAN, COUNTY OF GARFIELD, STATE OF COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE WESTERLY RIGHT OF WAY UNE OF COLORADO STATE HIGHWAY 82, WHENCE A 2 1/2" BRASS CAP, FOUND IN PLACE AND PROPERLY MARKED A5 THE SOUTHEAST CORNER OF SAID SECTION 7, BEARS S 7601'43" E A DISTANCE OF 2054.18 FEET; THENCE, ALONG SAID WESTERLY RIGHT OF WAY LINE N 09'35'10" W A DISTANCE OF 188.14 THENCE, 282.60 FEET ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 2915.00 FEET, A CENTRAL ANGLE OF 633'17" AND SUBTENDING A CHORD BEARING OF N 12'21'49" W A DISTANCE OF 28249 FEET; THENCE, DEPARTING SAID RIGHT OF WAY UNE S 90'0000" E A DISTANCE OF 49.74 FEET; THENCE, S 06'01'00" E A DISTANCE OF 202.70 FEET; THENCE, 5 04'3458" E A DISTANCE OF 260.70 FEET TO THE POINT OF BEGINNING, CONTAINING AN AREA OF 0.234 ACRES, MORE OR LESS. THE NAME AND ADDRESS OF THE PERSON WHO CREATED THIS LEGAL DESCRIPTION 15: JEFFREY ALLEN TUTTLE, P.L.S, 33638 727 BLAKE AVENUE GLENWOOD SPRINGS, COLORADO 81601 Owner/Developer: RiVerEdge COLORADO Carbondale Investments, LLC 7999 HWY 82 Carbondale, CO 81623 Phone No: 970.456.5325 LEGAL DESCRIPTION - PARCEL 8 (SOUTH PARCEL) - RIVERS EDGE PUD A TRACT OF LAND SITUATED IN THE EAST HALF OF SECTION 12, TOWNSHIP 7 SOUTH, RANGE 89 WEST, AND IN THE WEST HALF OF SECTION 7 AND IN THE NORTH HALF OF SECTION 18, TOWNSHIP 7 SOUTH, RANGE 88 WEST OF THE 6TH PRINCIPAL MERIDIAN, COUNTY OF GARFIELD, STATE OF COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE WESTERLY RIGHT OF WAY LINE OF COLORADO STATE HIGHWAY 82, WHENCE A 2 1/2" BRASS CAP, FOUND IN PLACE AND CORRECTLY MARKED A5 THE SOUTHEAST CORNER OF SAID SECTION 7, BEARS S 7649'20" E A DISTANCE OF 2150.14 FEU; THENCE, ALONG SAID RIGHT OF WAY LINE S 09'35'09 E A DISTANCE OF 401.79 FEET; THENCE, S 0913709 E A DISTANCE OF 1545.87 FEET; THENCE, 626.05 FEET ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 1482.50 FEET, A CENTRAL ANGLE OF 24'11'44" AND 511BTE900<0 A CHORD BEARING OF 5 21'41'02" E A DISTANCE OF 621,41 FEET; THENCE, 5 33'4654 E A DISTANCE OF 387.28 FEET; THENCE, 294.32 FEET ALONG THE ARC OF A CURVE TO THE RIGHT, HAVING A RADIUS OF 2815,00 FEET, A CENTRAL ANGLE OF 559126" AND SUBTENDING A CHORD BEARING OF 5 3014711 E A DISTANCE OF 294.19 FEET; THENCE, DEPARTING SAID RIGHT OF WAY LINE N 89'5716 W A DISTANCE OF 218.07 FEET; THENCE, N 40'23'30 W A DISTANCE OF 69,38 FEET, THENCE, S 87'2029 W A DISTANCE OF 36.35 FEET; THENCE S 83'52'12 W A DISTANCE OF 10.80 FEET; THENCE, N 58'27'19 W A DISTANCE OF 41.45 FEET; THENCE N 29'51'31 W A DISTANCE OF 8.20 FEET; THENCE N 24'16'24 W A DISTANCE OF 25.22 FEET; THENCE N 69'00'53 W A DISTANCE OF 9.87 FEET; THENCE, S 87'31'44 W A DISTANCE OF 22.60 FEET; THENCE, N 57'25'01 W A DISTANCE OF 17,28 FEET; THENCE, N 5009'49 W A DISTANCE OF 26.07 FEET; THENCE, N 4821'12 W A DISTANCE OF 9.99 FEET; THENCE, N 44'28'05 W A DISTANCE OF 21.45 FEET; THENCE, N 55'5008 W A DISTANCE OF 49,05 FEET; THENCE, N 56'25'40 W A DISTANCE OF 49.94 FEET, THENCE, N 68'12'23 W A DISTANCE OF 36.45 FEET; THENCE, N 46'54'04 W A DISTANCE OF 55.18 FEET; THENCE, N 6649'21 W A DISTANCE OF 2514 FEET; THENCE, N 47'41'50 W A DISTANCE OF 78.78 FEET; THENCE, N 30'26'40 W A DISTANCE OF 24.58 FEET; THENCE, N 254701 W A DISTANCE OF 30.08 FEET; THENCE, N 18'11'39 W A DISTANCE OF 34.61 FEET; THENCE, N 30'5621 W A DISTANCE OF 29.32 FEET; THENCE, N 21'59'14 W A DISTANCE OF 2750 FEET; THENCE, N 30'1607 W A DISTANCE OF 22.97 FEET; THENCE, N 2641'38 W A DISTANCE OF 169.44 FEET; THENCE, N 41'1739 E A DISTANCE OF 82.61 FEET; THENCE, N 3634'52 E A DISTANCE OF 15.89 FEET; THENCE, N 34'2644 W A DISTANCE OF 262.40 FEET; THENCE, N 57'58'09 W A DISTANCE OF 10247 FEET; THENCE, N 53'4031 W A DISTANCE OF 105.38 FEET; THENCE, N 5658'11 W A DISTANCE OF 126.13 FEET; THENCE, N 56'14'57 W A DISTANCE OF 118.42 FEET; THENCE, N 49'1604 W A DISTANCE OF 136.33 FEET; THENCE, N 443051 W A DISTANCE OF 150,05 FEET; THENCE, N 32'49'55 W A DISTANCE OF 102.14 FEET; THENCE, 9 37'44'19 W A DISTANCE OF 552.12 FEET; THENCE, N 18'1052 W A DISTANCE OF 47.26 FEET; THENCE, 9 275819 W A DISTANCE OF 109.20 FEET; THENCE, N 3601'36 W A DISTANCE OF 71.09 FEET; THENCE, 9 41'3747 W A DISTANCE OF 152.23 FEET; THENCE, N 40'22'24 W A DISTANCE OF 33982 FEET; THENCE, N 64'2053 W A DISTANCE OF 34.06 FEET; THENCE, N 460036 W A DISTANCE OF 52.42 FEET; THENCE, N 44'5041 W A DISTANCE OF 154,66 FEET; THENCE, N 32'3648 W A DISTANCE OF 86.59 FEET; THENCE, N 5701'32 W A DISTANCE OF 44.89 FEET; THENCE, N 30'3712 W A DISTANCE OF 8572 FEET; THENCE, N 3739'02 W A DISTANCE OF 79.09 FEET; THENCE, N .373730 W A DISTANCE OF 63.32 FEET; THENCE, N 200715 W A DISTANCE OF 33.98 FEET; THENCE, N 39'52'25 W A DISTANCE OF 42.02 FEET; THENCE, N 25'3604 W A DISTANCE OF 107,17 FEET; THENCE, N 30'34'08 W A DISTANCE OF 164.72 FEET; THENCE, N 11439'01 W A DISTANCE OF 107,90 FEET; THENCE, N 24'5606 E A DISTANCE OF 163.60 FEET; THENCE, N 6739'33 E A DISTANCE OF 177.81 FEET; THENCE, N 8714'43 E A DISTANCE OF 393.54 FEET; THENCE, N 0775'26 W A DISTANCE OF 21.79 FEET; THENCE, N 8051'11 E A DISTANCE OF 50.00 FEET; THENCE, N 891806 E A DISTANCE OF 65.56 FEET; THENCE, N 575004 E A DISTANCE OF 50.12 FEET; THENCE, S 84'51'15 E A DISTANCE OF 33,08 FEET, THENCE, S 81'39'50 E A DISTANCE OF 89.61 FEET; THENCE, N 56'07'00 E A DISTANCE OF 26.86 FEET; THENCE, N 073031 E A DISTANCE OF 2793 FEET; THENCE, N 3741'57 W A DISTANCE OF 28.06 FEET; THENCE, N 50'00'15 E A DISTANCE OF 22.23 FEET; THENCE, N 82'02'30 E A DISTANCE OF 36.49 FEET; THENCE, S 6734'38 E A DISTANCE OF 54.05 FEET; THENCE, 5 45'5758 E A DISTANCE OF 20.95 FEET, THENCE, S 14'4420 E A DISTANCE OF 29.18 FEET; THENCE, 5 11'11'17 W A DISTANCE OF 26.42 FEET; THENCE, 5 14'5041 E A DISTANCE OF 30.14 FEET; THENCE, 5 43'42'10 E A DISTANCE OF 69.77 FEET, THENCE, S 31'36159 E A DISTANCE OF 56.76 FEET; THENCE, 5 49'3046 E A DISTANCE OF 4012 FEET, THENCE, 5 45'3055 E A DISTANCE OF 40.88 FEET; THENCE, 5 60'1038 E A DISTANCE OF 43.39 FEET, THENCE, S 771624 E A DISTANCE OF 67.60 FEET; THENCE, 5 53'0615 E A DISTANCE OF 15.86 FEET, THENCE, S 673730 E A DISTANCE OF 52.31 FEET; THENCE, 5 83'2021 E A DISTANCE OF 46.95 FEET, THENCE, N 86'20'27 E A DISTANCE OF 61.04 FEET; THENCE, N 3159'09 E A DISTANCE OF 47.07 FEET; THENCE, N 0858'38 E A DISTANCE OF 32.16 FEET; THENCE, N 720007 E A DISTANCE OF 798 FEET; THENCE, S 24'51'03 E A DISTANCE OF 72.35 FEET; THENCE, 5 41'52'47 E A DISTANCE OF 5071 FEET, THENCE, 5 54'4421 E A DISTANCE OF 38.31 FEET; THENCE, S 83'3919 E A DISTANCE OF 87,15 FEET, THENCE S 5711'12 E A DISTANCE OF 77.06 FEET; THENCE, S 41'51'16 E A DISTANCE OF 88.65 FEET, THENCE, S 5739'13 E A DISTANCE OF 6560 FEET; THENCE 5 49'5/38 E A DISTANCE OF 7496 FEET, THENCE, 5 61'0452 E A DISTANCE OF 43.44 FEET; THENCE, 5 71'4603 E A DISTANCE OF 55.45 FEET TO THE POINT OF BEGINNING, CONTAINING. AN AREA OF 85.924 AGRES, MORE OR LESS. THE NAME AND ADORESSS OF THE PERSON WHO CREATED THIS LEGAL DESCRIPTION IS: JEFFREY ALLEN TUTTLE, P,LS. 33638 727 BLAKE AVENUE GLENWOOD SPRINGS, COLORADO 81601 Title: PROJECT SITE LOCATION AND DESCRIPTION (1 OF 4) Prepared by: 8140 Partners, LLC Date: 12/01/10 Exhibit: App. B-3 BITS\MISC REPORT FIGURES \PUD -L 02 PRELIM PLAT\ENGINEERING & DESIGN\CAC 9 Owner/Developer: RiVerEdge COLORADO Carbondale Investments, LLC 7999 HWY 82 Carbondale, CO 81623 44 \ \ \ \ /3� , \ \\ �7 \A 200 0 200 400 �` \\ * * ‘, �\ \ ` \\ \ • \\ \ \ \\ : ,\ \ \ \ ,\ \ \ \ T PARCEL A (NORTH PARCEL) o6 Izs *r ua^ai L130 L17.-,���-'P 4 r \ y4 uz ul ` 1111, II II o II' III I\ III I I VI 4</1/,(-) \ ,) // 60 \\ •V AA\ \� �/ / \ . ',\ III // I4 ' \\ I (( II II vv Av a to 1_ T N III )/ \\ I ll I \ ` \ \ \ ` 1 , \\ \\ I I \\ \ \\I \I \\ \h I \ .. ,\ \, \\ \ I I \\ II \\ \ \ . \ II \ \\\ \ \\\1 ` [166 SCALE IN FEET Phone No: 970.456.5325 Title: [I41�•4� \"-\ °"� �'� PRCEL C ey`, a \ \ (SOUTHEAST PI.RCEL) PARCEL B (SOUTH PARCEL) I\ CAITL_f CREEK \ I I I i Date: PROJECT SITE LOCATION AND DESCRIPTION (2 OF 4) Prepared by: 8140 Partners, LLC 12/01/10 Exhibit: App. B-4 BITS\MISC REPORT FIGURES \PUD -L 02 PRELIM PLAT\ENGINEERING & DESIGN\CAC ~fit 1� ` PARCEL A \\ ` \ 1.25 LIB � t, =is---' = �A , (NORTH PARCEL) `v � I• 4,7'~7, ;1 41r �.� I; �— PARCEL (SOUTHEAST �k PARCEL) cgTTtE. CREEK PARCEL B � (SOUTH PARCEL) I 1- r I I I Oo I ' I I ' I ' \ „� L I I I I \ 0 v I \ ; I \' `L II \ $' \ V II I II I I I k I •• I I I 1 Qpq \NiNN I c ,,o, 1 ' I o'b \ \ \ 1 MATCHLINE \ \\ s \ \ \ •` <0iv \ N • \ •\ \\ •.` 2 \ ,,E, ,� zoo 200 4':.'S '' .,063s ' SCALE IN FEET 4 \ Owner/Developer: RiVerEdge COLORADO Carbondale Investments, LLC 7999 HWY 82 Carbondale, CO 81623 Phone No: 970.456.5325 Title: PROJECT SITE LOCATION AND DESCRIPTION (3 OF 4) Prepared by: 8140 Partners, LLC CURVE TABLE (PROPERTY BOUNDARY) 01.11816 RADIUS LENGTH CHORD BEARING DELTA C1 281500 494.34 49370 N 14'37'1" W 10'03'42" C2 1482.50 626.05 621.41 5 21'41'2" E 24'11'44" C3 2815.00 29432 294.19 N 30'47'11" W 5'59'26" C4 2915.00 282.60 282.49 N 12'21'49" W 533'17" Owner/Developer: e _ _fie COLORADO Carbondale Investments, LLC 7999 HWY 82 Carbondale, CO 81623 Phone No: 970.456.5325 LINE TABLE (PROPERTY BOUNDARY) LINE LENGTH 8 ARM LINE LENGTH BEARING Ll 1005.44 89'4330 E L85 25.14 N 6049'21" W L2 2644.53 19'38'52" E L86 78.78 N 47'41'50" W L3 120.78 5 0359" E L87 24.58 N 30'26'40" W L4 60.45 0536'13" W L88 30.08 N 25'47'1" W L5 64.72 49'54'10" W L89 3461 N 1111'39' W L6 86.97 49'54'10" W L90 29.32 N 30'5121" W L7 5430 48'17'10" W L91 27.50 N 21'59'14' W 48 123.97 56'47'27" W L92 22.97 N 3016'7° W L9 93.00 83'47'24" W L93 169.44 N 2141'38" W L10 119.58 2035'31" W L94 82.61 6 41'17'39' E L11 33.84 N 78'043 8 L95 15.89 N 3034'52' E L12 3780 79'41'48" W 496 262.40 N 34'26'44" W 613 56.05 22'57'52" W L97 102.47 N 5758'9" W L14 4548 59'31'57° W 498 105.38 N 53'43'31° W L15 2823 8732'35" 8 L99 126.13 9 5158'11' W 616 95.71 N 5073" W 4100 11842 N 58'14'57° W L17 85.73 71'20'44" W L101 136.33 N 4016'4" W 618 93.22 36'43'10° W L102 150.05 6 44'3051° W L19 181.92 25'39'22" W L103 102.14 N 374985' W L20 98.43 6010'24" W L104 552.12 N 37'44'19" W L21 52.20 S 812'33" W L105 47.26 N 18'10'2° W L22 39.34 56'3352° W L106 109.20 N 2758'19° W L23 42.96 2049'33' W L107 71.09 N 35'1'36" W L24 21.60 372743" E L108 152.23 N 41'32'47" W L25 89.66 N 77'2'57" W L109 339.82 N 4022'24° W L26 70.95 70'24'18" W L110 34.06 N 64'20'53' 19 L27 55.55 88'5939 8 L111 52.42 N 45036" 19 L28 49.93 84'28158" W L112 154.66 N 44'53'41° W L29 68.20 14'22'48" E 6113 86.59 N 32'35'48" W 130 77.59 N 5'11'46" W L114 44.89 N 571'32" W L31 1082 N 18'20'5" E L115 85.72 N 3033'12" W L32 44.14 N 22'53'40" E L116 79.09 N 3739'2° W L33 35.11 N 10134'58" E 6117 63.32 6 37'32'30" W L34 47.16 N 8'59'51" E L118 33.98 N 222'15° W L35 36.48 N 3'48'8" E L119 42.02 N 3952'25" W L36 71.03 N 4'40'52" E L120 107.17 N 25'36'4" W L37 54.66 N 73751" E L121 16472 N 30'34'8" W L38 63.68 29'28'14" W L122 107.90 N 11'39'1" W L39 61.05 N 32113244" W 1123 16360 N 24356' E L40 55.52 26'17'29" W L124 177.81 N 63'39'33" E L41 44.36 38114'36" W L125 393.54 N 83'14'43" E L42 37.73 5211'32" W L126 21.79 N 7'15'26" W L43 54.16 59'54'48" W L127 50.00 N 8051'11" E L44 36.97 875735" W L128 65.56 N 8975'6" E L45 65.70 57'33'47" W 4129 50.12 N 57'50'4" E L46 85.02 81'56'22" W L130 33.08 5 84'51'15" E L47 158.65 9 4'11'29" W L131 89.61 S 81'39'50" E L48 41 30 35'5041" W L132 26.86 N 56'7'0° E L49 2470 N 54'46'3" W L133 27.93 N 738'31" E 650 209.99 28'51'45" W L134 2806 N 37'41'57" W 451 33.82 11'58'37" W 6135 22.23 N 50'0'15" E L52 78.19 N 41'3'46" E L136 36.49 N 82'2'30° E L53 117.20 N 629'1" W L137 54.05 S 653438" E L54 94.24 6 205'27 W L138 20.95 5 45'59'58° E L55 63.83 N 11'32'3" W L139 29.18 S 14'44'20" E L56 141.45 N 7'57'45" W L140 26.42 9 11'11'17° W L57 50.76 N 556'14" E L141 30.14 S 1458'41" E L58 91.04 N 19'17'44" W L142 69.77 5 43'42'10° E 159 134.55 N 44'41'59" W 043 56.76 5 31'36'59" E 1.60 74.18 N 19'23'49" W L144 40.12 5 4038'46° E L61 43.27 N 18306" W L145 40.88 5 45'30'55" E 662 72.23 N 21'30'1" W L146 43.39 5 60'16'38' E L63 217.77 N 716'30" E L147 67.60 S 73'16'24" E L64 31294 N 0'16'30" E LI48 15.86 5 53'5'15" E L65 401.79 S 9'35'9" E L149 5231 S 63'37'30" E L66 1545.87 5 9'35'9" E LI 50 46.95 5 83'28'21° E L67 387.28 33'46'54" E L151 61.04 6 8620'27° E L68 218.07 89'53'16" W L152 47.07 N 31'59'9° E L69 69.38 4023'30" W 1153 32.16 9 68038" E L70 36.35 87'28'29 W L154 7.98 N 72'8'7° E L71 10.80 83"52'12" W L155 72.35 S 24'51'3° E L72 41.45 58'2719" W 6756 50.71 5 41'52'47" E L73 8.28 29'51'31" W 6157 38.31 S 5444'21" E L74 25.22 24'16'24" W L158 87.15 5 03'39'39" E L75 9.87 N 69'053" W L159 77.06 5 5711'12" E 176 22.60 8731'44" W LI60 88.65 5 41'51'16° E L77 17.28 N 5725'1" W 4161 65.60 5 5739'13" E L78 26.07 N 58049" W 6162 74.96 5 49'55'38' E L79 999 N 4621'12" W L163 4344 S 61'4'52" E L80 21.45 N 44'285 W L164 55.45 5 71'46'2" E L81 49.05 N 55'50'8" W L165 188.14 9 035'117 W L82 49.94 N 56'25'40" W L166 49.74 E LB3 36.45 N 6811523" W 6167 202.70 5 6'1'0" E L84 55.18 N 46'54'4" W 6168 260.70 5 434'56" E Title: PROJECT SITE LOCATION AND DESCRIPTION (4 OF 4) Prepared by: 8140 Partners, LLC Date: 12/01/10 Exhibit: App. B-6 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado APPENDIX B: WILL SERVE LETTERS App. B-1 Comcast. May 27, 2010 Rockwood Shepard, Carbondale Investments, LLC. c/o 8140 Partners, LLC Mark Sawyer Eagle, Colorado RE: Carbondale Investments, LLC Eagle, Colorado Dear Mark: Please accept this letter as confirmation of Comcast of Colorado/Florida, Inc.'s ability to provide cable service to the captioned location. The provision of service is contingent upon successful negotiations of an agreement between the developer and Comcast Cable. Should you require additional information, please contact Michael Johnson at 970-205- 5432 or mobile at 970-930-4713. Sincerely, Michael Johnsoth Sr. Construction Professional Colorado Market This letter is not intended to give rise to binding obligations for either party. Any contractual relationship between the parties will be the result of formal negotiations and will only become effective upon execution of the contract by representatives of the parties authorized to enter into such agreements. During any negotiations, each party will bear its own costs and will not be responsible for any costs or expenses of the other party, unless separately agreed to in writing, App. B-2 Sourceas May 26, 2010 From: Carla. Westerman SourceGas 0096 County Rd. 160 Glenwood Springs, CO 81601 970-928-0407 To: Rockwood Shepard, Carbondale Investments, LLC C/O 8140 Partners, LLC PO Box 426 Eagle, CO 81631 RE: Carbondale Investments, LLC Project To whom it may concern: The above mentioned development is within the certificated service area of SourceGas. 1 have received your vicinity map, and master plan for this project. SourceGas has existing natural gas facilities located on or near the above mentioned project. At this time it appears that these existing facilities have adequate capacity to provide natural gas service to your project, subject to the tariffs, rules and regulations on file. Any upgrading of our facilities necessary to deliver adequate service to and within the development will be undertaken by SourceGas upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please contact us with any questions regarding this project, and with a timeline of when you would like to proceed with your project. S it core 1pv, Ir f C .a Westerman •Field Coordinator App. B-3 Qwest Communications 5325 Zuni St, 728 Denver, CO 80221 DONNA MASTRIONA Tracking # 5504 Will Serve 27 -May -10 10:02:46 AM SUBJECT: Telephone facilities to planned / proposed development. Attn: CARBONDALE INVESTMENTS LLC nr MAW MARK SAWYER____._._....µM.....,.�,...�,..._.__.... xc 1143 CAPITAL STREET SUITE 205 EAGLE, CO 81631 krtaafb t MIP t. 303-549-7730 ,14113 Mark.Saw er@8140Partners.com Qwest will provide service to your planned / proposed developement: CATTLE CREEK tia 7 7S 68W - 6TH GARFIELD Provisioning the service will be in accordance with tariffs on file at the Colorado Public Utilities Commission. 1 will need a final plat with measurements, easements, addresses, your phasing plan, and a trench plan before I can have this engineered. If there are any further questions, or if I can provide any assistance, please contact me. DONNA MASTRIONA 303-451-2390 (LDA Coordinator) (Phone) Sincerely App. B-4 Qwest. Spirit of Service CONSTRUCTION HANDBOOK FOR DEVELOPERS App. B-5 Qwest's Colorado LDA Coordinators DENVER METRO & BOULDER COUNTY Estella Martinez 700 W. Mineral Ave Rm NDC05.12 Littleton, Co 80120 303-707-7726 COLORADO OUT -STATE NORTH WESTERN SLOPE Donna Mastriona 5325 Zuni St Rm 728 Denver, Co 80221 303-451-2390 COLORADO OUT -STATE SOUTH Cathy Mourhess 700 W Mineral Ave Rm NDC05.18 Denver CO 80120 303-707-7273 App. B-6 RESIDENTIAL LOTS =1 0 OR MORE SINGLE FAMILY UNITS 1. REQUIRED DOCUMENTS A. Master Plans B. Addresses C. Recorded Plats — two copies — 24" x 36" D. Phasing Maps E. Trench and backfill plans and specifications -- Electric design F. Construction schedules G. Advance notification of trench date and completion of first living unit 2. DEVELOPERS RESPONSIBILITIES A. Joint trench, sole trench, and backfill B. Service laterals — 1" conduit — from the living unit to the Qwest pedestal, and lateral trench C. Granting non-exclusive easements D. Developer's name, address, telephone number E. Contact person's name, address, telephone number F. Location of construction trailers and model homes 3. QWESTS RESPONSIBILITIES A. Ownership of installed plant B. Timely completion of Qwest feeder and distribution cable and plant C. Timely engineering, design, ordering of materials, and placement and testing of cable facilities D. Opening and backfilling of trench, should Qwest miss the advanced notice of open trench 4. LDA COSTS A. UP TO $528.40 per lot allowed towards construction costs B. Developer, prior to cable placement, must pay charges above $528.40 per lot. C. Qwest will reimburse to the developer $79.77 per lot for the cost of opening trench and backfill, if the construction costs are less than $528.40 per lot. D. Qwest will not reimburse to the developer more than the $528.40 per lot. App. B-7 E. Allotted standard placing crew mobilizations. a. 1 to 50 lots = 2 trips to complete cable placement 51 to 100 lots = 3 trips to complete cable placement 100 to 150 Lots = 4 trips to complete cable placement 150+ lots = 5 trips to complete cable placement b. Allotted trips based upon documented averages for placing cable in above mentioned various size subdivisions plus 1 additional day. c. Additional trips to site due to developer not having entire trench available or power company requirements that the trench be closed daily that require excessive mobilizations may be billed to developer at actual labor costs. App. B-8 GENERAL INFORMATION 1. Call us in advance Call when you have a preliminary plat, especially if your project is the first filing in an undeveloped area. Placing cable in your subdivision is only one part of providing telephone facilities. We may need to place additional facilities and equipment, requiring many weeks of planning design and construction. 2. Meet with us face-to-face Our local Field Engineer should discuss your plans in detail and resolve any issues with a face-to-face meeting. This is essential for a large, phased project. 3. Joint trench—It's your responsibility QWEST requires (BY THE TARIFF) the developer to provide trench for telephone cable either by sole trench or joint trench. If the trench is to be joint (provided by the power company), it is the developers responsibility to schedule a mutually agreeable date for that trench opening 2 weeks prior, and to maintain control of the closing of that trench per the terms and conditions of section 4D of the LDA agreement. If the developer provided trench places our cable out of easement, it is the developers FINANCIAL RESPONSIBILITY to have the cable relocated, spliced and paid for the cost of the material. Many power companies are adopting a close trench daily policy. This policy does not adhere to the terms of the section 4D of the LDA agreement and is not acceptable to QWEST. We will make reasonable attempts to place cable under these circumstances, however, our crews must visit many developments on a daily basis and are not obligated to visit your site every day. Any trenches missed due to power company close daily policy must be reopened by the developer at his expense. If you wish to have a crew on your site full time on a daily basis, you will be required to contact the local coordinator in advance to arrange for billing of labor costs over standard construction intervals (identified above). These costs normally will run $300 to $500 per day depending upon the location of your development until construction is complete. App. B-9 GENERAL REQUIREMENTS (CONTINUED) 4. Schedule your trench well in advance. Call your area coordinator at least 30 days from anticipated trench opening to allow time for material ordering and to insure availability of a construction crew to place cable. 5. Pre -construction Meetings It is MANDATORY to schedule a pre -construction meeting 1-2 weeks in advance of the trench opening. This is a good opportunity to address final scheduling and trenching issues or other problems that may arise, such as walls, gates, landscaping, etc. 6. Trench Opening Call us a few days in advance of actual trench opening to confirm that material is on hand and a crew is scheduled to be on site when the trench is opened. Please call us when the trench date is changed so that a crew is not mobilized unnecessarily to the site when no trench is open and ready. 7. Final Grade Be very certain that the subdivision is within 6 inches of final grade before opening the trench. Developer will billed full costs if we are required to raise or lower cable or pedestals due to grade change. S. Easements In addition to the 8' to 10' utility easement provided on the plats for cable placement, we may require a pocket easement for our equipment. Sizes may vary from 10' X 20' to 30' X 30'. If it is discovered that our cable is out of easement after it has been placed, the developer is responsible for providing a new trench and pay any costs associated with placing the cable in correct easements. App. B-10 GENERAL REQUIREMENTS (CONTINUED) 9. Addresses — Why are they so important? The homeowner will not get telephone service without an address. Addresses are built into our database for telephone assignment of the customer's service order. An Address Plat is required for this purpose and the developer is responsible for well in advance to avoid delays in pre -provisioning a home and have dial tone available when a homeowner moves in. 10. Road Crossings A 4" (four inch) Schedule 40 PVC conduit is required for road crossings. Do not rely totally on the power prints to determine road crossing for Qwest. Sometimes we will need additional crossings where the power company is not going. Please call if you are ready to place road crossings and do not have a job print. Crossings can generally be decided in advance of final job prints. 11. Trenches The developer is required to provide all joint use and sole trench. Maintain a 30' to 36' minimum trench depth for cable. Grade is to be within 6" of final at time of cable placement. Provide backfill which shall consist of sound earth material, which contains no rocks larger than 1". Backfill shall be free from concrete, lumber, asphalt, metal, vegetation, or other debris. If cable damage occurs from objects in the backfill, the developer will be billed for damages. App. B-11 Pedestal Placement & Bonding Configurations Telco Pedestal Telco Cables Less Than 10' Power Pedestal or Transformer Separation awg. Solid Copper Wire —MGN Power (Elec.) Cables 64.0.**AOsisA AAA6.1:h1.44-0.2%04*.e. .........*Aithise.:02AAAAAAfafeanithe.:01±1.zAesia6.***4ahie.+-4,2:AAAAfatts.144.4 Telco Pedestal Telco Cables First Closest Telco Pedestal 4i6 awg. Solid Copper Wire United Power Transformer Cabinet Power (Elec.) Cables App. B-12 0 0 MGN .1- -----'---------IP — Power (Elec.) Cables App. B-12 Property Line & Cold Zone Clearances (typical rear lot configuration) Mirdroutrk allowable clearance between telco pedestal and property line( s).. >.< -2' r Minimum "cold zone --clearances must be observed from all directions of power apparatus_ 3' "Cold Zone" Mini mum pl App. B-13 May 25, 2010 8140 Partners, LLC Attn: Karen Otero PO Box 426 Eagle. CO Si 63 1-0426 3799 HIGHWAY 32 • PO. BOX 2150 GLENWOOD SPRINGS, t_.OLGRADO 81602 (970) 945-5491 • FAX (970) 945-4081 RE: Carbondale Investments, LLC Project To Whom it May Concern: The above mentioned development is within the certificated service area of Holy Cross Energy. Holy Cross Energy has existing power facilities located on or near the above mentioned project. These existing facilities have adequate capacity to provide electric power to the development, subject to the tariffs, rules and regulations on file. Any power line enlargements, relocations, and new extensions necessary to deliver adequate power to and within the development will be undertaken by Holy Cross Energy upon completion of appropriate contractual agreements and subject to necessary governmental approvals. Please advise when you wish to proceed with the development of the electric system for this project. Sincerely, HOLY CROSS ENERGY Kenton Berner, Engineering Department kberner@holycross.com (970) 947-5497 KB:vw Berner\Ocero T It [rrr�e Enertp, q,orttrvcVitt?' App. B-14 Project Engineering Design Report River Edge Colorado, Garfield County, Colorado APPENDIX C: STORM SEWER, INLET AND CULVERT SIZING App. C-1 ST -Output -North Design Log InRoads Storm & Sanitary Design Log Drainage File: P:\Carbondale Investments\06.00 Design Tasks\06.02 - Task 02 Prelim Plat\Engineering & Design\Calculations\InRoads\SDB\REC - Drain.sdb Design File: C:\DOCUMENTS AND SETTINGS\JADAMS\MY DOCUMENTS\8140\CCX 2010\REC REV PLAN 9-2-10 WORKING\DRAINAGE WORKING 11-10-10.DWG Display Log: C:\DOCUMENTS AND SETTINGS\JADAMS\MY DOCUMENTS\8140\CCX 2010\REC REV PLAN 9-2-10 WORKING\design.log Date: Monday, November 29, 2010 11:57:42 AM Designing inlet IN -MOD -ONLY -4 WARNING: Spread is greater than maximum spread (2.50 ft ) Results: Gutter Flow: 17.1119 cfs Flow From: Area Time of Concentration ENABLED Tc: 5.0000 min Intensity: 5.8200 in/h Sum C x Area: 2.9402 ac Ave Runoff Coef: 0.3800 Status: Inlet Length: Flow Downstream: Percent Cap: Spread: Depth in Gutter: Fixed 6.0000 ft 17.1119 cfs 100.0000 10.2984 ft 0.1878 ft Designing pipe P -MOD -ONLY -5 WARNING: Full flow velocity is greater Inlet width: Capacity: Assigned Bypass: than maximum (10.00) 2.0000 ft 17.1125 cfs N/A Results: Total Flow: 17.1119 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 5.0189 min Sum C x Area: 2.9402 ac Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 30.0000 in 0.7310 ft 1.3900 ft 14.2902 ft/s 3.4753 Designing manhole ST -MH -N-14 Results: Total Flow: 17.1119 cfs Time of Concentration ENABLED Tc: 5.0189 min Status: Fixed Intensity: Ave Runoff Coef: Page 1 Slope: Pipe Height: Flow Status: Capacity: Flow Regime: Flow From: Sum C x Area: 5.8200 in/h 0.0000 0.0500 ft/ft 30.0000 in Partial 91.7171 cfs Supercritical Upstream 2.9402 ac App. C-2 Chamber Width: ST -Output -North 5.0000 ft Chamber Length: Designing pipe ST -P -N-15 WARNING: Full flow velocity is greater than maximum (10.00) 5.0000 ft Results: Total Flow: 17.0974 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 5.0689 min Sum C x Area: 2.9402 ac Status: Fixed Pipe width: 30.0000 in Depth of Flow: 0.9290 ft Critical Depth: 1.3900 ft Velocity: 10.2799 ft/s Froude Number: 2.1860 Designing manhole ST -MH -N-13 Results: Total Flow: 17.0974 cfs Time of Concentration ENABLED Tc: 5.0689 min Status: Chamber width: Fixed 5.0000 ft Intensity: 5.8151 in/h Ave Runoff Coef: 0.0000 Slope: 0.0200 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 58.0070 cfs Flow Regime: SuperCritical Flow From: Upstream Sum C x Area: 2.9402 ac Chamber Length: 5.0000 ft Designing pipe ST -P -N-14 WARNING: Full flow velocity is greater than maximum (10.00) Results: Total Flow: 17.0592 cfs Time of Concentration ENABLED Tc: 5.2798 min Sum C x Area: 2.9402 ac Status: Fixed Pipe width: 30.0000 in Depth of Flow: 1.0040 ft Critical Depth: 1.3900 ft Velocity: 9.2421 ft/s Froude Number: 1.8789 Designing manhole ST -MH -N-12 Results: Total Flow: 17.0592 cfs Time of Concentration ENABLED Tc: 5.2798 min Status: Chamber width: Fixed 5.0000 ft Flow From: Upstream Intensity: 5.8021 in/h Ave Runoff Coef: 0.0000 Page 2 Slope: 0.0150 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 50.2355 cfs Flow Regime: SuperCritical Flow From: Upstream Sum C x Area: 2.9402 ac Chamber Length: 5.0000 ft App. C-3 ST -Output -North Designing pipe ST -P -N-13 WARNING: Full flow velocity is greater than maximum (10.00) Results: Total Flow: 16.8980 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 5.6093 min Intensity: 5.7473 in/h Sum C x Area: 2.9402 ac Ave Runoff Coef: 0.0000 Status: Fixed Pipe width: 30.0000 in Depth of Flow: 0.9990 ft Critical Depth: 1.3900 ft Velocity: 9.2159 ft/s Froude Number: 1.8790 Designing manhole ST -MH -N-11 Results: Total Flow: 16.8980 cfs Time of Concentration ENABLED Tc: 5.6093 min Status: Chamber width: Fixed 5.0000 ft Slope: 0.0150 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 50.2355 cfs Flow Regime: Supercritical Flow From: Upstream Sum C x Area: 2.9402 ac Chamber Length: 5.0000 ft Designing pipe ST -P -N-12 WARNING: Full flow velocity is greater than maximum (10.00) Results: Total Flow: 16.6461 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 5.7582 min Sum C x Area: 2.9402 ac Status: Fixed Pipe width: 30.0000 in Depth of Flow: 0.9900 ft Critical Depth: 1.3700 ft Velocity: 9.1889 ft/s Froude Number: 1.8834 Designing manhole ST -MH -N-10 Results: Total Flow: 16.6461 cfs Time of Concentration ENABLED Tc: 5.7582 min Status: Chamber width: Fixed 5.0000 ft Intensity: 5.6616 in/h Ave Runoff Coef: 0.0000 Slope: 0.0150 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 50.2355 cfs Flow Regime: Supercritical Flow From: Upstream Sum C x Area: 2.9402 ac Chamber Length: 5.0000 ft Designing pipe ST -P -N-11 WARNING: Full flow velocity is greater than maximum (10.00) Page 3 App. C-4 ST -Output -North Results: Total Flow: 16.5322 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 5.9151 min Sum C x Area: 2.9402 ac Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 30.0000 in 0.9870 ft 1.3700 ft 9.1632 ft/s 1.8815 Designing manhole ST -MH -N-9 Results: Total Flow: 16.5322 cfs Time of Concentration ENABLED Tc: 5.9151 min Status: Chamber width: Fixed 5.0000 ft Intensity: 5.6229 in/h Ave Runoff Coef: 0.0000 Slope: 0.0150 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 50.2355 cfs Flow Regime: SuperCritical Flow From: Upstream Sum C x Area: 2.9402 ac Chamber Length: 5.0000 ft Designing pipe ST -P -N-10 WARNING: Full flow velocity is greater than maximum (10.00) Results: Total Flow: 16.4124 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 6.0553 min Intensity: 5.5821 in/h Sum C x Area: 2.9402 ac Ave Runoff Coef: 0.0000 Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 30.0000 in 0.9830 ft 1.3600 ft 9.1463 ft/s 1.8825 Designing inlet MOD -ONLY -1 Results: Gutter Flow: 5.5368 cfs Slope: 0.0150 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 50.2355 cfs Flow Regime: SuperCritical Flow From: Area Time of Concentration ENABLED Tc: 5.0000 min Intensity: 5.8200 in/h Sum C x Area: 0.9513 ac Ave Runoff Coef: 0.4200 Status: Fixed Inlet Length: 6.0000 ft Inlet width: 2.0000 ft Flow Downstream: 5.5368 cfs Percent Cap: 100.0000 % Capacity: 10.6098 cfs Spread: 0.0079 ft Depth in Gutter: 0.0001 ft Assigned Bypass: N/A Designing pipe P -MOD -ONLY -2 Page 4 App. C-5 ST -Output -North Results: Total Flow: 5.5368 cfs Time of Concentration ENABLED Tc: 5.0602 min Sum C x Area: 0.9513 ac Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 30.0000 in 0.6240 ft 0.7700 ft 5.7695 ft/s 1.5291 Designing manhole ST -MH -N-8 Results: Total Flow: 21.5809 cfs Time of Concentration ENABLED Tc: 6.0553 min Status: Chamber width: Fixed 5.0000 ft Designing pipe ST -P -N-9 WARNING: Full flow velocity is greater Results: Total Flow: 21.5809 cfs Time of Concentration ENABLED Tc: 6.3914 min Sum C x Area: 3.8915 ac Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 30.0000 in 1.1440 ft 1.5700 ft 9.8445 ft/s 1.8511 Designing manhole ST -MH -N-7 Results: Total Flow: 21.5809 cfs Time of Concentration ENABLED Tc: 6.3914 min Status: Chamber width: Designing pipe ST -P -N-8 Fixed 5.0000 ft Results: Total Flow: 21.2408 cfs Flow From: Upstream Intensity: 5.8200 in/h Ave Runoff Coef: 0.0000 Slope: 0.0097 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 40.4694 cfs Flow Regime: SuperCritical Flow From: Sum C x Area: Chamber Length: than maximum (10.00) Upstream 3.8915 ac 5.0000 ft Flow From: Upstream Intensity: Ave Runoff Coef: Page 5 Slope: Pipe Height: Flow Status: Capacity: 5.5456 in/h 0.0000 0.0150 ft/ft 30.0000 in Partial 50.2355 cfs Flow Regime: Supercritical Flow From: Sum C x Area: Chamber Length: Upstream 3.8915 ac 5.0000 ft Flow From: Upstream App. C-6 ST -Output -North Time of Concentration ENABLED Tc: 6.6685 min Sum C x Area: 3.8915 ac Ave Status: Fixed Pipe width: 30.0000 in Depth of Flow: 1.4100 ft Critical Depth: 1.5600 ft velocity: 7.4379 ft/s Froude Number: 1.2224 Designing manhole ST -MH -N-6 Results: Total Flow: 21.2408 cfs Time of Concentration ENABLED Tc: 6.6685 min Status: Chamber width: Designing pipe ST -P -N-7 Fixed 5.0000 ft Results: Total Flow: 20.9605 cfs Time of Concentration ENABLED Tc: 6.8019 min Sum C x Area: 3.8915 ac Status: Fixed Pipe Width: 30.0000 in Depth of Flow: 1.5740 ft Critical Depth: 1.5500 ft Velocity: 6.4343 ft/s Froude Number: 0.9770 Designing manhole ST -MH -N-5 Results: Total Flow: 20.9605 cfs Time of Concentration ENABLED Tc: 6.8019 min Status: Chamber width: Designing pipe ST -P -N-6 Fixed 5.0000 ft Results: Total Flow: 20.8255 cfs Time of Concentration ENABLED Tc: 7.0626 min Sum C x Area: 3.8915 ac Status: Fixed Intensity: 5.4582 in/h Runoff Coef: 0.0000 Slope: 0.0072 ft/ft Pipe Height: 30.0000 in Flow Status: Partial Capacity: 34.8196 cfs Flow Regime: Flow From: Sum C x Area: Chamber Length: Flow From: Intensity: Ave Runoff Coef: Slope: Pipe Height: Flow Status: Capacity: Flow Regime: Flow From: Sum C x Area: Chamber Length: Flow From: Intensity: Ave Runoff Coef: Page 6 Slope: Supercritical Upstream 3.8915 ac 5.0000 ft Upstream 5.3862 in/h 0.0000 0.0050 ft/ft 30.0000 in Partial 29.0035 cfs Critical Upstream 3.8915 ac 5.0000 ft Upstream 5.3515 in/h 0.0000 0.0050 ft/ft App. C-7 Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Designing channel CH -N-1 Results: Total Flow: ST -Output -North 30.0000 in Pipe Height: 30.0000 in 1.5670 ft Flow Status: Partial 1.5500 ft Capacity: 29.0035 cfs 6.4262 ft/s 0.9790 Flow Regime: Critical 80.1713 cfs Time of Concentration ENABLED Tc: 26.8736 min Sum C x Area: 26.1008 ac Status: Left Side Slope: Maximum Depth: Depth of Flow: Critical Depth: Velocity: Fixed 1.0000 ft/ft 4.0000 ft 2.8828 ft 2.1920 ft 4.7273 ft/s Flow From: Area Intensity: Ave Runoff Coef: Slope: Right Side Slope: Channel Bottom: Top width: 3.0716 in/h 0.4463 0.0053 ft/ft 1.0000 ft/ft 3.0000 ft 8.7656 ft Designing culvert CV -N-1 Results: Total Flow: 75.4013 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 27.0452 min Intensity: 2.8888 in/h Sum C x Area: 26.1008 ac Ave Runoff Coef: 0.0000 Control: Outlet Inlet Control Eqn: Entrance Loss Status: Fixed Slope: 0.0115 ft/ft Culvert width: 48.0000 in Culvert Height: 48.0000 in Critical Depth: 1.8300 ft Num Barrels: 2 Headwater: 3.1973 ft Tailwater: 3.3600 ft velocity: 3.3456 ft/s WARNING: Culvert too large for upstream channel Designing channel CH -N-2 Results: Total Flow: 75.0760 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 29.1802 min Sum C x Area: 26.1008 ac Status: Left Side Slope: Maximum Depth: Depth of Flow: Critical Depth: Velocity: Fixed 1.0000 ft/ft 4.0000 ft 2.6953 ft 2.1150 ft 4.8907 ft/s Intensity: Ave Runoff Coef: Slope: Right Side Slope: Channel Bottom: Top width: WARNING: Channel too small for upstream culvert. Designing pipe ST -P -N-5 Results: Page 7 2.8764 in/h 0.0000 0.0059 ft/ft 1.0000 ft/ft 3.0000 ft 8.3906 ft App. C-8 ST -Output -North Total Flow: 70.6180 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 29.8390 min Sum C x Area: 26.1008 ac Status: Fixed Pipe width: 48.0000 in Depth of Flow: 2.9590 ft Critical Depth: 2.5400 ft velocity: 7.0829 ft/s Froude Number: 0.7411 Designing manhole ST -MH -N-4 Results: Total Flow: 70.6180 cfs Time of Concentration ENABLED Tc: 29.8390 min Status: Chamber width: Designing pipe ST -P -N-4 Fixed 5.0000 ft Intensity: 2.7056 in/h Ave Runoff Coef: 0.0000 Slope: 0.0030 ft/ft Pipe Height: 48.0000 in Flow Status: Partial Capacity: 78.6767 cfs Flow Regime: Subcritical Flow From: Upstream Sum C x Area: 26.1008 ac Chamber Length: 5.0000 ft Results: Total Flow: 69.2423 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 30.5300 min Sum C x Area: 26.1008 ac Status: Fixed Pipe Width: 48.0000 in Depth of Flow: 2.9120 ft Critical Depth: 2.5100 ft Velocity: 7.0626 ft/s Froude Number: 0.7504 Designing manhole ST -MH -N-3 Results: Total Flow: 78.7030 cfs Time of Concentration ENABLED Tc: 30.5300 min Status: Chamber Width: Designing pipe ST -P -N-3 Fixed 5.0000 ft Intensity: 2.6529 in/h Ave Runoff Coef: 0.0000 Slope: 0.0030 ft/ft Pipe Height: 48.0000 in Flow Status: Partial Capacity: 78.6767 cfs Flow Regime: Subcritical Flow From: Upstream Sum C x Area: 29.9924 ac Chamber Length: 5.0000 ft Results: Total Flow: 78.7030 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 30.7472 min Sum C x Area: 29.9924 ac Intensity: Ave Runoff Coef: Page 8 2.6241 in/h 0.0000 App. C-9 ST -Output -North Status: Fixed Pipe Width: 48.0000 in Depth of Flow: 3.2790 ft Critical Depth: 2.6800 ft Velocity: 7.1365 ft/s Froude Number: 0.6645 Designing manhole ST -MH -N-2 Results: Total Flow: 78.7030 cfs Time of Concentration ENABLED Tc: 30.7472 min Status: Chamber Width: Designing pipe ST -P -N-2 Fixed 5.0000 ft Slope: 0.0030 ft/ft Pipe Height: 48.0000 in Flow Status: Partial Capacity: 78.6767 cfs Flow Regime: Subcritical Flow From: Upstream Sum C x Area: 29.9924 ac Chamber Length: 5.0000 ft Results: Total Flow: 78.5075 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 30.9286 min Sum C x Area: 29.9924 ac Status: Pipe width: Depth of Flow: Critical Depth: Velocity: Froude Number: Fixed 48.0000 in 3.2700 ft 2.6800 ft 7.1367 ft/s 0.6669 Designing manhole ST -MH -N-1 Results: Total Flow: 78.5075 cfs Time of Concentration ENABLED Tc: 30.9286 min Status: Chamber width: Designing pipe ST -P -N-1 Fixed 5.0000 ft Intensity: 2.6176 in/h Ave Runoff Coef: 0.0000 Slope: 0.0030 ft/ft Pipe Height: 48.0000 in Flow Status: Partial Capacity: 78.6767 cfs Flow Regime: Subcritical Flow From: Upstream Sum C x Area: 29.9924 ac Chamber Length: 5.0000 ft Results: Total Flow: 78.3443 cfs Flow From: Upstream Time of Concentration ENABLED Tc: 31.0287 min Sum C x Area: 29.9924 ac Status: Fixed Pipe Width: 48.0000 in Depth of Flow: 3.2630 ft Critical Depth: 2.6800 ft Intensity: 2.6121 in/h Ave Runoff Coef: 0.0000 Page 9 Slope: 0.0030 ft/ft Pipe Height: 48.0000 in Flow Status: Partial Capacity: 78.6767 cfs App. C-10 velocity: Froude Number: HGL/EGL Computations: Table A: Struct_ID Dn_Soffit EGLdn (ft) (ft) Outfall ST -Output -North 7.1359 ft/s 0.6688 Flow Regime: subcritical D Q L v d dc vA2/2g Sf HGLdn Tot_Loss EGLup HGLup Rim_Elev. (in) (cfs) (ft) (ft/s) (ft) (ft) (ft) (ft/ft) (ft) (ft) (ft) (ft) (ft) - - - - - 6005.25 (Alternate HGL and EGL used) 6006.12 6005.33 ST -P -N-1 48 78.34 42.85 7.14 6005.99 6006.12 6005.33 0.13 6006.25 6005.46 ST -MH -N-1 - - - - 6006.25 6005.46 0.20 6006.45 6005.66 6006.81 ST -P -N-2 48 78.51 77.67 6.25 6006.11 6006.45 6005.66 0.23 6006.68 6006.08 ST -MH -N-2 - 6006.68 6006.08 0.20 6006.89 6006.28 6008.95 ST -P -N-3 48 78.70 93.03 6.26 6006.33 6006.89 6006.28 0.28 6007.17 6006.56 ST -MH -N-3 - - - - 6007.17 6006.56 0.35 6007.52 6006.91 6010.11 ST -P -N-4 48 69.24 292.79 5.51 6006.60 6007.52 6006.91 0.68 6008.20 6007.72 ST -MH -N-4 - 6008.20 6007.72 0.03 6008.23 6007.76 6011.36 ST -P -N-5 48 70.62 280.00 5.62 6007.45 6008.23 6007.76 0.68 6008.90 6008.41 CH -N-2 - - - - - 6006.98 3.72 - 6010.70 CV -N-1 - - - - - 6011.36 0.23 - 6011.59 CH -N-1 - - - 6011.28 3.60 New Branch ST -MH -N-3 - 6007.17 6006.56 ST -P -N-6 30 6005.10 6007.26 6006.65 ST -MH -N-5 - 6007.52 6007.24 ST -P -N-7 30 6005.57 6007.62 6007.34 ST -MH -N-6 - 6007.75 6007.47 ST -P -N-8 30 6005.81 6007.86 6007.58 ST -MH -N-7 - 6008.19 6007.90 ST -P -N-9 30 6014.88 - 6007.17 6006.56 0.09 6007.26 6006.65 6010.11 20.83 100.49 4.24 0.26 6007.52 6007.24 0.10 6007.62 6007.34 6009.59 20.96 51.53 4.27 0.13 6007.75 6007.47 0.11 6007.86 6007.58 6009.53 21.24 123.63 4.33 0.33 6008.19 6007.90 0.29 6008.48 6008.19 6008.91 21.58 198.54 4.40 Page 10 3.26 2.68 0.79 0.0030 - - 0.61 0.0030 - - 0.61 0.0030 - - 0.47 0.0023 - - 0.49 0.0024 0.28 0.0026 0.28 0.0026 0.29 0.0027 0.30 0.0028 App. C-11 6006.66 6008.48 6008.19 ST -MH -N-8 - 6009.03 6008.73 (Alternate HGL and ST -Output -North 0.55 6009.03 6008.73 0.08 6009.11 6008.81 6012.46 EGL Used) 6009.29 6008.99 16.41 76.97 9.15 - 6011.37 6010.07 ST -P -N-10 30 6009.56 6010.29 6008.99 ST -MH -N-9 - 6011.37 6010.07 ST -P -N-11 30 6010.64 6010.43 6009.13 ST -MH -N-10 - 6011.65 6010.35 ST -P -N-12 30 6011.86 6011.66 6010.35 ST -MH -N-11 - 6012.82 6011.51 ST -P -N-13 30 6013.02 6012.84 6011.52 ST -MH -N-12 - 6015.49 6014.17 ST -P -N-14 30 6015.67 6015.51 6014.18 ST -MH -N-13 - 6017.19 6015.86 ST -P -N-15 30 6017.35 6017.43 6015.78 ST -MH -N-14 - 6017.94 6016.30 P -MOD -ONLY -5 30 6017.87 6019.27 6016.10 IN -MOD -ONLY -4 - 6019.81 6016.64 New Branch ST -MH -N-8 - 6009.03 6008.73 P -MOD -ONLY -2 30 6009.56 6008.20 6007.69 MOD -ONLY -1 - 6008.36 6007.85 Table B: LOSSES -1LOSS_COEFFICENTS Str_ID Dstr Ko Outfall 6011.37 6010.07 6013.43 16.53 86.22 9.16 - 6011.65 6010.35 6011.65 6010.35 6014.85 16.65 82.09 9.19 - 6012.82 6011.51 6012.82 6011.51 6016.59 16.90 182.23 9.22 - 6015.49 6014.17 6015.49 6014.17 6019.70 17.06 116.96 9.24 - 6017.19 6015.86 6017.19 6015.86 6022.02 17.10 30.81 10.28 - 6017.94 6016.30 6017.94 6016.30 6022.38 17.11 16.21 14.29 - 6019.81 6016.64 6019.81 6016.64 6022.17 6009.03 6008.73 0.98 1.36 1.30 0.99 1.37 1.30 0.99 1.37 1.31 1.00 1.39 1.32 1.00 1.39 1.33 0.93 1.39 1.64 0.73 1.39 3.17 0.04 6009.07 6008.77 6012.46 5.54 20.83 5.77 0.62 0.77 0.52 - 6008.36 6007.85 - Hf CD Cd ST -P -N-1 0.13 ST -MH -N-1 - 3.35 0.565 1.000 0.449 ST -P -N-2 0.23 ST -MH -N-2 - 3.75 0.697 1.000 0.481 ST -P -N-3 0.28 6008.36 6007.85 6011.97 Hb Hstr Hc He Cq Cp Cb K - 0.20 - - 1.000 1.000 1.000 0.254 - 0.20 - - 1.000 1.000 1.000 0.335 Page 11 Hj Total 0.13 0.20 0.23 0.20 0.28 App. C-12 ST -Output -North ST -MH -N-3 - - 0.35 - - - 0.35 3.96 1.448 1.000 0.497 0.796 1.000 1.000 0.573 ST -P -N-4 0.68 - - - - - 0.68 ST -MH -N-4 - - 0.03 - - - 0.03 4.27 0.125 1.000 0.520 1.000 1.000 1.000 0.065 ST -P -N-5 0.68 - - - - - 0.68 CH -N-2 CV -N-1 CH -N-1 New Branch - - - - - - - ST -MH -N-3 - - 0.09 - - - 0.09 3.96 1.448 1.000 0.497 0.206 1.000 1.000 0.148 ST -P -N-6 0.26 - - - - - 0.26 ST -MH -N-5 - - 0.10 - - - 0.10 4.16 0.521 1.000 0.679 1.000 1.000 1.000 0.354 ST -P -N-7 0.13 - - - - - 0.13 ST -MH -N-6 - - 0.11 - - - 0.11 4.16 0.571 1.000 0.679 1.000 1.000 1.000 0.388 ST -P -N-8 0.33 - - - - - 0.33 ST -MH -N-7 - - 0.29 - - - 0.29 3.74 1.553 1.000 0.637 1.000 1.000 1.000 0.989 ST -P -N-9 0.55 - - - - - 0.55 ST -MH -N-8 - - 0.08 - - - 0.08 1.67 0.633 1.000 0.392 1.123 1.000 1.000 0.279 ST -P -N-10 - - - - - - SuperCrt ST -MH -N-9 ST -P -N-11 - - - - - - SuperCrt ST -MH -N-10 ST -P -N-12 - - - - - - SuperCrt ST -MH -N-11 ST -P -N-13 - - - - - - SuperCrt ST -MH -N-12 ST -P -N-14 - - - - - - SuperCrt ST -MH -N-13 ST -P -N-15 - - - - - - SuperCrt ST -MH -N-14 P -MOD -ONLY -5 - - - - - - SuperCrt IN -MOD -ONLY -4 - - - - - - - Page 12 App. C-13 ST -Output -North 0.73 New Branch - - - - - - - ST -MH -N-8 - - 0.04 - - - 0.04 1.67 1.531 1.000 0.392 0 226 1.000 1.000 0.135 P -MOD -ONLY -2 - - - - - - SuperCrt MOD -ONLY -1 - - - - - - - 0.62 - Page 13 App. C-14 Project: Channel ID: Capacity Analysis of Composite Channel River Edge Colorado Section B - Grass Lined w/Trickle Minor N -left N -If Left Overbank Area Low Flow Channel N -right Right Overbank Area 1 ZL Alternate Overbank Toe Protection BL Bm BR ZR Ym 1 Yob Design Information (Inputt Channel Invert Slope Low Flow Channel Bottom Width Low Flow Channel Left Side Slope Low Flow Channel Right Side Slope Low Flow Channel Manning's Nn for Qd Low Flow Channel Manning's Nn for Q100 (See USDCM Vol. II, n vs. Depth Graph) Low Flow Channel Bank -full depth So = 0.01400 ft/ft Left Overbank Bottom Width Left Overbank Side Slope 2.00 ft Left Overbank Manning's n 0.00 ft/ft Right Overbank Bottom Width 0.00 ft/ft Right Overbank Side Slope 0.0130 Right Overbank Manning's n Bm = Z1 = Z2 = n -If = n -m -Q100 = Ym = 0.0200 0.50 ft Overbank Flow Depth Yob (Y - Ym) BL = 0.50 ft ZL = 4.00 ft/ft n -left = 0.0400 BR= 0.50 ft ZR = 4.00 ft/ft n -right = 0.0400 Yob = 0.50 ft Low Flow Channel Condition for Qd Top width Flow area Wetted perimeter Discharge (Calculated) Velocity Froude number Qd Critical Velocity Qd Critical Depth Left Overbank Flow Condition for 0100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Top width Channel Depth Y Flow area Wetted perimeter Cross -Sectional Manning's n (Calculated) Tlf = 2.0 ft Af = 1.0 sq ft Plf = 3.0 ft Qlf = 6.5 cfs VIf= 6.5 fps Fr -If = 1.62 Vlfc = 4.71 fps Ylfc = 0.69 ft TL = 2.5 ft AL = 0.7500 sq ft PL = 2.5600 ft QL = 1.5 cfs VL = 1.9 fps FrL = 0.63 VLc = 2.8 fps YLc = 0.4 ft Low Flow Channel Flow Condition for Q100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth Right Overbank Flow Condition for 0100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Composite Cross -Section Flow Condition for Q100 T = 7.0 ft Y= 1.00 ft A= 3.5sgft P= 8.1 ft n = 0.0215 Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Tm = 2.0 ft Am = 2.0 sq ft Pm= 3.O ft Qm = 13.5 cfs Vm = 6.7 fps Frm = 1.19 Vmc = 4.5 fps Ymc = 1.0 ft TR = 2.5 ft AR = 0.7500 sq ft PR = 2.5600 ft QR = 1.5 cfs VR= 1.9 fps FrR= 0.63 VRc = 2.8 fps YRc = 0.4 ft Q = 16.4 cfs V= 4.7 fps Fr= 1.17 Vc = 4.1 fps Yc = 0.57 ft App. C-15 Section C - Grass Lined trickle minor - Channel_v1.04.xlsm, Composite Analysis 1/13/2011, 11:55 AM Normal Flow Analysis - Trapezoidal Channel Project: Channel ID: River Edge Colorado Section A - riprap minor Z1 T B Z2 1 Design Information (Input) Channel Invert Slope Manning's n Bottom Width Left Side Slope Right Side Slope Freeboard Height Design Water Depth So = n= B= Z1 = Z2 = F= Y= 0.0050 0.035 2.00 3.00 3.00 0.50 1.50 ft/ft ft ft/ft ft/ft ft ft Normal Flow Condtion (Calculated) Discharge Froude Number Flow Velocity Flow Area Top Width Wetted Perimeter Hydraulic Radius Hydraulic Depth Specific Energy Centroid of Flow Area Specific Force Q= Fr = V= A= T= P= R= D= Es = Yo = Fs = 26.31 0.51 2.70 9.75 11.00 11.49 0.85 0.89 1.61 0.57 0.49 cfs fps sq ft ft ft ft ft ft ft kip Section B - Riprap Minor - Channel_v1.04.xlsm, Basics 1/13/2011, 11:54 AM App. C-16 Critical Flow Analysis - Trapezoidal Channel Project: Channel ID: River Edge Colorado Section A - riprap minor F v Z1 T B Z2 1 Design Information (Input) Bottom Width Left Side Slope Right Side Slope Design Discharge B= Z1 = Z2 = Q= 3.00 1.50 1.50 94.00 ft ft/ft ft/ft cfs Critical Flow Condition (Calculated) Critical Flow Depth Critical Flow Area Critical Top Width Critical Hydraulic Depth Critical Flow Velocity Froude Number Critical Wetted Perimeter Critical Hydraulic Radius Critical (min) Specific Energy Centroid on the Critical Flow Area Critical (min) Specific Force Y= A= T= D= V= Fr = P= R= Esc = Yoc = Fsc = 2.19 13.76 9.57 1.44 6.83 1.00 10.90 1.26 2.91 0.71 1.86 ft sq ft ft ft fps ft ft ft ft kip Section B - Riprap Minor - Channel_v1.04.xlsm, Basics 1/13/2011, 11:54 AM App. C-17 Normal Flow Analysis - Trapezoidal Channel Project: Channel ID: River Edge Colorado Section C - Riprap Major Z1 T B Z2 1 Design Information (Input) Channel Invert Slope Manning's n Bottom Width Left Side Slope Right Side Slope Freeboard Height Design Water Depth So = n= B= Z1 = Z2 = F= Y= 0.0050 0.035 3.00 1.50 1.50 0.50 3.00 ft/ft ft ft/ft ft/ft ft ft Normal Flow Condtion (Calculated) Discharge Froude Number Flow Velocity Flow Area Top Width Wetted Perimeter Hydraulic Radius Hydraulic Depth Specific Energy Centroid of Flow Area Specific Force Q= Fr = V= A= T= P= R= D= Es = Yo = Fs = 93.75 0.54 4.17 22.50 12.00 13.82 1.63 1.88 3.27 1.19 2.43 cfs fps sq ft ft ft ft ft ft ft ki p Section A - Riprap Major_UD-Channel_v1.04.xlsm, Basics 1/13/2011, 11:54 AM App. C-18 Critical Flow Analysis - Trapezoidal Channel Project: Channel ID: River Edge Colorado Section C - Riprap Major F v Z1 T B Z2 1 Design Information (Input) Bottom Width Left Side Slope Right Side Slope Design Discharge B= Z1 = Z2 = Q= 3.00 1.50 1.50 94.00 ft ft/ft ft/ft cfs Critical Flow Condition (Calculated) Critical Flow Depth Critical Flow Area Critical Top Width Critical Hydraulic Depth Critical Flow Velocity Froude Number Critical Wetted Perimeter Critical Hydraulic Radius Critical (min) Specific Energy Centroid on the Critical Flow Area Critical (min) Specific Force Y= A= T= D= V= Fr = P= R= Esc = Yoc = Fsc = 2.19 13.76 9.57 1.44 6.83 1.00 10.90 1.26 2.91 0.71 1.86 ft sq ft ft ft fps ft ft ft ft kip Section A - Riprap Major_UD-Channel_v1.04.xlsm, Basics 1/13/2011, 11:54 AM App. C-19 River Edge Colorado Project: Channel ID: Capacity Analysis of Composite Channel N -left N -If Left Overbank Area Low Flow Channel N -right Right Overbank Area 1 ZL Alternate Overbank Toe Protection BL Bm BR ZR Ym 1 Yob Design Information (Inputt Channel Invert Slope Low Flow Channel Bottom Width Low Flow Channel Left Side Slope Low Flow Channel Right Side Slope Low Flow Channel Manning's Nn for Qd Low Flow Channel Manning's Nn for Q100 (See USDCM Vol. II, n vs. Depth Graph) Low Flow Channel Bank -full depth So = 0.01400 ft/ft Left Overbank Bottom Width Left Overbank Side Slope 3.00 ft Left Overbank Manning's n 0.00 ft/ft Right Overbank Bottom Width 0.00 ft/ft Right Overbank Side Slope 0.0130 Right Overbank Manning's n Bm = Z1 = Z2 = n -If = n -m -Q100 = Ym = 0.0200 0.50 ft Overbank Flow Depth Yob (Y - Ym) BL = 1.00 ft ZL = 4.00 ft/ft n -left = 0.0400 BR= 1.00 ft ZR = 4.00 ft/ft n -right = 0.0400 Yob = 1.00 ft Low Flow Channel Condition for Qd Top width Flow area Wetted perimeter Discharge (Calculated) Velocity Froude number Qd Critical Velocity Qd Critical Depth Left Overbank Flow Condition for 0100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Top width Channel Depth Y Flow area Wetted perimeter Cross -Sectional Manning's n (Calculated) Tlf = 3.0 ft Alf= 1.5sgft Plf = 4.0 ft Qlf = 10.6 cfs VIf= 7.1 fps Fr -If = 1.76 Vlfc = 4.84 fps Ylfc = 0.73 ft TL = AL = PL = QL = VL = FrL = VLc = YLc = 5.0 ft 3.0000 sq ft 5.1200 ft 9.3 cfs 3.1 fps 0.70 4.1 fps 0.8 ft Low Flow Channel Flow Condition for Q100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth Right Overbank Flow Condition for 0100 Top width Flow area Wetted perimeter Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Composite Cross -Section Flow Condition for Q100 T= Y= A= P= n= 13.0 ft 1.50 ft 10.5 sq ft 14.3 ft 0.0246 Discharge Velocity Froude number 100 -Yr. Critical Velocity 100 -Yr. Critical Depth in Overbanks Tm = 3.0 ft Am= 4.5sgft Pm= 4.O ft Qm = 42.9 cfs Vm = 9.5 fps Frm = 1.37 Vmc = 5.7 fps Ymc = 1.5 ft TR = 5.0 ft AR = 3.0000 sq ft PR = 5.1200 ft QR = 9.3 cfs VR= 3.1 fps FrR= 0.70 VRc= 4.1 fps YRc = 0.8 ft Q = 61.4 cfs V= 5.9 fps Fr = 1.15 Vc = 5.2 fps Yc = 1.09 ft App. C-20 Section D - Grass Lined trickle major_UD-Channel_v1.04.xlsm, Composite Analysis 1/13/2011, 11:56 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-04 sutwerl a reason culrerts.secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =1 24.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kr = Ks= Cd = KEio„,= 2 6012.5 0.014 45.00 0.0130 0.00 1.00 0.20 0.56 1.76 0.99 -0.6439 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 6012.50 0.00 0.00 0.00 No flow (WS < inlet) 6012.75 0.56 0.04 0.04 min. energy equation 6013.00 2.98 0.98 0.98 min. energy equation 6013.25 6.68 6.68 6.68 min. energy equation 6013.50 11.10 12.38 11.10 min. energy equation 6013.75 12.86 17.10 12.86 regression equation 6014.00 17.64 21.86 17.64 regression equation 6014.25 23.00 25.78 23.00 regression equation 6014.50 28.40 29.20 28.40 regression equation 6014.75 33.44 32.28 32.28 regression equation 6015.00 38.00 35.14 35.14 regression equation 6015.25 42.12 38.28 38.28 regression equation 6015.50 45.88 40.74 40.74 regression equation 6015.75 49.36 43.48 43.48 regression equation 6016.00 52.62 45.70 45.70 regression equation 6016.25 55.70 48.16 48.16 regression equation 6016.50 58.64 50.22 50.22 regression equation 6016.75 61.44 52.46 52.46 regression equation 6017.00 64.16 54.38 54.38 regression equation 6017.25 66.78 56.46 56.46 regression equation 6017.50 69.34 58.46 58.46 regression equation 6017.75 71.82 60.22 60.22 regression equation 6018.00 74.22 62.12 62.12 regression equation 6018.25 76.58 63.94 63.94 regression equation 6018.50 78.86 65.72 65.72 orifice equation 6018.75 80.84 67.32 67.32 orifice equation 6019.00 82.74 69.02 69.02 orifice equation 6019.25 84.60 70.68 70.68 orifice equation 6019.50 86.42 72.28 72.28 orifice equation 6019.75 88.20 73.86 73.86 orifice equation Processing Time: CULV-S-04 v2.00c.xlsm, Culvert 1.92 seconds App. C-21 1/13/2011,12:00 PM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-04 6021.00 6020.00 6019.00 6018.00 6017.00 aai 6016.00 • as CO 6015.00 cn 6014.00 6013.00 6012.00 0.00 STAGE -DISCHARGE CURVE FOR THE CULVERT 20.00 40.00charge (c6fsgpp. 0 Dis 0 Inlet Control a Outlet Control tStage-Discharge 80.00 100.00 CULV-S-04 v2.00c.xlsm, Culvert App. C-22 1/13/2011, 12:00 PM • A ❑ 1 A m • A 20.00 40.00charge (c6fsgpp. 0 Dis 0 Inlet Control a Outlet Control tStage-Discharge 80.00 100.00 CULV-S-04 v2.00c.xlsm, Culvert App. C-22 1/13/2011, 12:00 PM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-03 sutwerl a reason ['Overt secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =1 18.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kl = Ks= Cd = KEie,,,= 2 6013.5 0.013 45.00 0.0130 0.00 1.00 0.20 0.82 2.02 0.99 -0.6437 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 6013.50 0.00 0.00 0.00 No flow (WS < inlet) 6013.75 0.48 0.28 0.28 min. energy equation 6014.00 2.44 4.04 2.44 min. energy equation 6014.25 5.42 7.32 5.42 min. energy equation 6014.50 7.00 10.02 7.00 regression equation 6014.75 10.32 12.56 10.32 regression equation 6015.00 13.84 14.68 13.84 regression equation 6015.25 17.06 16.54 16.54 regression equation 6015.50 19.88 18.22 18.22 regression equation 6015.75 22.36 19.76 19.76 regression equation 6016.00 24.60 21.22 21.22 regression equation 6016.25 26.64 22.74 22.74 regression equation 6016.50 28.58 24.04 24.04 regression equation 6016.75 30.38 25.38 25.38 regression equation 6017.00 32.12 26.56 26.56 regression equation 6017.25 33.78 27.78 27.78 regression equation 6017.50 35.38 28.92 28.92 regression equation 6017.75 36.94 30.02 30.02 regression equation 6018.00 38.44 31.10 31.10 orifice equation 6018.25 39.74 32.16 32.16 orifice equation 6018.50 40.96 33.12 33.12 orifice equation 6018.75 42.14 34.12 34.12 orifice equation 6019.00 43.30 35.08 35.08 orifice equation 6019.25 44.42 36.02 36.02 orifice equation 6019.50 45.52 36.94 36.94 orifice equation 6019.75 46.58 37.80 37.80 orifice equation 6020.00 47.62 38.66 38.66 orifice equation 6020.25 48.66 39.52 39.52 orifice equation 6020.50 49.66 40.36 40.36 orifice equation 6020.75 50.64 41.18 41.18 orifice equation Processing Time: CULV-S-03 v2.00c.xlsm, Culvert 1.22 seconds App. C-23 1/13/2011, 11:59 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-03 6022.00 6021.00 6020.00 6019.00 6018.00 aai 6017.00 • as CO 6016.00 6015.00 6014.00 6013.00 0.00 STAGE -DISCHARGE CURVE FOR THE CULVERT 10.00 20.00 30.00 40.00 Discharge (cfs) 0 Inlet Control a Outlet Control tStage-Discharge 50.00 60.00 CULV-S-03 v2.00c.xlsm, Culvert App. C-24 1/13/2011, 11:59 AM ♦ ♦ ❑ ❑ ♦ ♦ ♦ 111 ❑ ❑ ❑ ♦ ♦ ♦ ❑ ❑ 111 ❑ ♦ ♦ ♦ ♦ ❑ ❑ ❑ ❑ ♦ ♦ ♦ ♦ ❑ ❑ ❑ ❑ Al ♦❑ • 1 • ■ A ■ A A ■♦ 10.00 20.00 30.00 40.00 Discharge (cfs) 0 Inlet Control a Outlet Control tStage-Discharge 50.00 60.00 CULV-S-03 v2.00c.xlsm, Culvert App. C-24 1/13/2011, 11:59 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-02 sutwerl a reason culrerts.secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =1 36.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kl = Ks= Cd = KEio„,= 2 5989.5 0.01 45.00 0.0130 0.00 1.00 0.20 0.32 1.52 0.99 -0.6367 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 5989.50 0.00 0.00 0.00 No flow (WS < inlet) 5989.75 0.74 0.04 0.04 min. energy equation 5990.00 2.62 0.02 0.02 min. energy equation 5990.25 8.06 0.02 0.02 min. energy equation 5990.50 13.62 0.02 0.02 min. energy equation 5990.75 24.00 2.64 2.64 min. energy equation 5991.00 30.52 13.62 13.62 min. energy equation 5991.25 31.24 24.00 24.00 regression equation 5991.50 39.32 35.94 35.94 regression equation 5991.75 48.34 46.02 46.02 regression equation 5992.00 58.08 54.90 54.90 regression equation 5992.25 68.12 63.08 63.08 regression equation 5992.50 78.00 69.92 69.92 regression equation 5992.75 87.40 76.20 76.20 regression equation 5993.00 96.22 84.16 84.16 regression equation 5993.25 104.46 89.56 89.56 regression equation 5993.50 112.14 96.14 96.14 regression equation 5993.75 119.38 101.24 101.24 regression equation 5994.00 126.20 107.36 107.36 regression equation 5994.25 132.68 111.82 111.82 regression equation 5994.50 138.86 117.38 117.38 regression equation 5994.75 144.80 121.58 121.58 regression equation 5995.00 150.52 126.72 126.72 regression equation 5995.25 156.04 131.66 131.66 regression equation 5995.50 161.40 135.52 135.52 regression equation 5995.75 166.60 140.14 140.14 regression equation 5996.00 171.68 144.62 144.62 regression equation 5996.25 176.64 148.24 148.24 regression equation 5996.50 181.50 152.48 152.48 regression equation 5996.75 186.24 156.62 156.62 regression equation Processing Time: CULV-S-02 v2.00c.xlsm, Culvert 3.38 seconds App. C-25 1/13/2011, 11:58 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-02 5998.00 5997.00 5996.00 5995.00 c 5994.00 aai 5993.00 • as CO 5992.00 cn 5991.00 5990.00 • ■ STAGE -DISCHARGE CURVE FOR THE CULVERT ♦ ■ ♦ 5989.00 0.00 ♦ ♦ • • • • ♦ 50.00 100.00 Discharge (cfs) 150.00 200.00 o Inlet Control a Outlet Control tStage-Discharge 1 CULV-S-02 v2.00c.xlsm, Culvert App. C-26 1/13/2011, 11:58 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-01 sutwerl a reason culrerts.secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =1 36.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kl = Ks= Cd = KEio„,= 2 5983.5 0.01 45.00 0.0130 0.00 1.00 0.20 0.32 1.52 0.99 -0.6367 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 5983.50 0.00 0.00 0.00 No flow (WS < inlet) 5983.75 0.74 0.04 0.04 min. energy equation 5984.00 2.62 0.02 0.02 min. energy equation 5984.25 8.06 0.02 0.02 min. energy equation 5984.50 13.62 0.02 0.02 min. energy equation 5984.75 24.00 2.64 2.64 min. energy equation 5985.00 30.52 13.62 13.62 min. energy equation 5985.25 31.24 24.00 24.00 regression equation 5985.50 39.32 35.94 35.94 regression equation 5985.75 48.34 46.02 46.02 regression equation 5986.00 58.08 54.90 54.90 regression equation 5986.25 68.12 63.08 63.08 regression equation 5986.50 78.00 69.92 69.92 regression equation 5986.75 87.40 76.20 76.20 regression equation 5987.00 96.22 84.16 84.16 regression equation 5987.25 104.46 89.56 89.56 regression equation 5987.50 112.14 96.14 96.14 regression equation 5987.75 119.38 101.24 101.24 regression equation 5988.00 126.20 107.36 107.36 regression equation 5988.25 132.68 111.82 111.82 regression equation 5988.50 138.86 117.38 117.38 regression equation 5988.75 144.80 121.58 121.58 regression equation 5989.00 150.52 126.72 126.72 regression equation 5989.25 156.04 131.66 131.66 regression equation 5989.50 161.40 135.52 135.52 regression equation 5989.75 166.60 140.14 140.14 regression equation 5990.00 171.68 144.62 144.62 regression equation 5990.25 176.64 148.24 148.24 regression equation 5990.50 181.50 152.48 152.48 regression equation 5990.75 186.24 156.62 156.62 regression equation Processing Time: CULV-S-01 v2.00c.xlsm, Culvert 3.45 seconds App. C-27 1/13/2011, 11:57 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-01 5992.00 5991.00 5990.00 5989.00 c 5988.00 aai 5987.00 • as CO 5986.00 cn 5985.00 5984.00 • ■ 1 A STAGE -DISCHARGE CURVE FOR THE CULVERT ♦ 000 • • • ♦ ■ 5983.00 0.00 50.00 100.00 Discharge (cfs) 150.00 200.00 o Inlet Control a Outlet Control tStage-Discharge 1 CULV-S-01 v2.00c.xlsm, Culvert App. C-28 1/13/2011, 11:57 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-N-01 suhnrl a reason culrerts.secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral 1p& Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =I 36.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kl = Ks= Cd = KEte,,,= 2 6008 0.005 45.00 0.0130 0.00 1.00 0.20 0.32 1.52 0.99 -0.3672 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 6008.00 0.00 0.00 0.00 No flow (WS < inlet) 6008.25 0.74 0.04 0.04 min. energy equation 6008.50 2.62 0.02 0.02 min. energy equation 6008.75 6.66 0.02 0.02 min. energy equation 6009.00 13.44 0.02 0.02 min. energy equation 6009.25 18.42 0.02 0.02 min. energy equation 6009.50 28.28 2.64 2.64 min. energy equation 6009.75 31.02 13.62 13.62 regression equation 6010.00 39.08 24.00 24.00 regression equation 6010.25 48.06 37.68 37.68 regression equation 6010.50 57.78 46.02 46.02 regression equation 6010.75 67.82 54.90 54.90 regression equation 6011.00 77.70 64.08 64.08 regression equation 6011.25 87.12 70.82 70.82 regression equation 6011.50 95.96 77.04 77.04 regression equation 6011.75 104.22 84.92 84.92 regression equation 6012.00 111.92 90.26 90.26 regression equation 6012.25 119.16 96.14 96.14 regression equation 6012.50 126.00 101.88 101.88 regression equation 6012.75 132.48 107.68 107.68 regression equation 6013.00 138.68 112.38 112.38 regression equation 6013.25 144.62 117.92 117.92 regression equation 6013.50 150.34 122.10 122.10 regression equation 6013.75 155.88 127.22 127.22 regression equation 6014.00 161.24 132.14 132.14 regression equation 6014.25 166.44 135.98 135.98 regression equation 6014.50 171.52 140.60 140.60 regression equation 6014.75 176.50 145.06 145.06 regression equation 6015.00 181.34 148.68 148.68 regression equation 6015.25 186.10 152.90 152.90 regression equation Processing Time: CULV-N-01_v2.00c.xlsm, Culvert 3.42 seconds App. C-29 1/13/2011, 11:57 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-N-01 6016.00 6015.00 6014.00 6013.00 6012.00 aai 6011.00 • as CO 6010.00 cn 6009.00 6008.00 6007.00 0.00 STAGE -DISCHARGE CURVE FOR THE CULVERT 50.00 100.00 Discharge (cfs) 150.00 o Inlet Control a Outlet Control tStage-Discharge 1 200.00 CULV-N-01_v2.00c.xlsm, Culvert App. C-30 1/13/2011, 11:57 AM • ❑ • • ❑ ❑ • • • ❑ ❑ ❑ • • • • ❑ ❑ ❑ ❑ • • • ❑ ❑ ❑ • ❑ • • • ❑ ❑ ❑ A ■ 50.00 100.00 Discharge (cfs) 150.00 o Inlet Control a Outlet Control tStage-Discharge 1 200.00 CULV-N-01_v2.00c.xlsm, Culvert App. C-30 1/13/2011, 11:57 AM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-05 sutwerl a reason culrerts.secure Design Information (Input): Circular Culvert: Barrel Diameter in Inches Inlet Edge Type (choose from pull-down list) OR: Box Culvert: Barrel Height (Rise) in Feet Barrel Width (Span) in Feet Inlet Edge Type (choose from pull-down list) 4stlral Number of Barrels Inlet Elevation at Culvert Invert Outlet Elevation at Culvert Invert OR Slope of Culvert (ft v./ft h.) Culvert Length in Feet Manning's Roughness Bend Loss Coefficient Exit Loss Coefficient Design Information (calculated): Entrance Loss Coefficient Friction Loss Coefficient Sum of All Loss Coefficients Orifice Inlet Condition Coefficient Minimum Energy Condition Coefficient Calculations of Culvert Capacity (outpu D =1 24.00 Grooved End with Headwall OR: nches Height (Rise) = ft. Width (Span) = ft. Square Edge w/ 30-78 deg. Flared W ingwall No = Inlet Elev = Slope = L= n= Kb = Kx = Ke = Kr = Ks= Cd = KEio„,= 2 6015 0.014 45.00 0.0130 0.00 1.00 0.20 0.56 1.76 0.99 -0.6439 ft. elev. ft vert. / ft horiz. ft. Water Surface Elevation (ft., linked) Tailwater Surface Elevation ft (input if known) Culvert Inlet -Control Flowrate cfs (output) Culvert Outlet -Control Flowrate cfs (output) Controlling Culvert Flowrate cfs (output) Inlet Equation Used: (output) 6015.00 0.00 0.00 0.00 No flow (WS < inlet) 6015.25 0.56 0.04 0.04 min. energy equation 6015.50 2.98 0.98 0.98 min. energy equation 6015.75 6.68 6.68 6.68 min. energy equation 6016.00 11.10 12.38 11.10 min. energy equation 6016.25 12.86 17.10 12.86 regression equation 6016.50 17.64 21.86 17.64 regression equation 6016.75 23.00 25.78 23.00 regression equation 6017.00 28.40 29.20 28.40 regression equation 6017.25 33.44 32.28 32.28 regression equation 6017.50 38.00 35.14 35.14 regression equation 6017.75 42.12 38.28 38.28 regression equation 6018.00 45.88 40.74 40.74 regression equation 6018.25 49.36 43.48 43.48 regression equation 6018.50 52.62 45.70 45.70 regression equation 6018.75 55.70 48.16 48.16 regression equation 6019.00 58.64 50.22 50.22 regression equation 6019.25 61.44 52.46 52.46 regression equation 6019.50 64.16 54.38 54.38 regression equation 6019.75 66.78 56.46 56.46 regression equation 6020.00 69.34 58.46 58.46 regression equation 6020.25 71.82 60.22 60.22 regression equation 6020.50 74.22 62.12 62.12 regression equation 6020.75 76.58 63.94 63.94 regression equation 6021.00 78.86 65.72 65.72 orifice equation 6021.25 80.84 67.32 67.32 orifice equation 6021.50 82.74 69.02 69.02 orifice equation 6021.75 84.60 70.68 70.68 orifice equation 6022.00 86.42 72.28 72.28 orifice equation 6022.25 88.20 73.86 73.86 orifice equation Processing Time: CULV-S-05 v2.00c.xlsm, Culvert 1.97 seconds App. C-31 1/13/2011,12:01 PM CULVERT STAGE -DISCHARGE SIZING (INLET vs. OUTLET CONTROL WITH TAILWATER EFFECTS) Project: River Edge Colorado Basin ID: CULV-S-05 6023.00 6022.00 6021.00 6020.00 g 6019.00 aai 6018.00 • as CO 6017.00 cn 6016.00 6015.00 6014.00 0.00 STAGE -DISCHARGE CURVE FOR THE CULVERT 20.00 40.00charge (c6fsgpp. 0 Dis 0 Inlet Control a Outlet Control tStage-Discharge 1 80.00 100.00 CULV-S-05 v2.00c.xlsm, Culvert App. C-32 1/13/2011, 12:01 PM • ❑ • • ❑ • • D ❑ • • • ❑ ❑ ❑ • • • • ❑ ❑ ❑ ❑ •\ A ■ ■ A ■ A A VA r• 20.00 40.00charge (c6fsgpp. 0 Dis 0 Inlet Control a Outlet Control tStage-Discharge 1 80.00 100.00 CULV-S-05 v2.00c.xlsm, Culvert App. C-32 1/13/2011, 12:01 PM