HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-09-16-4422 Double D Investments, LLC — Dean Dombrowski Remodel of Existing Mixed -Use Occupancy Building 43 County Road 110 (Cattle Creek Road) Glenwood Springs, Colorado 1) ALL WORK SHALL COMPLY WITH THE 2015 IBC, IMC, IPC, IFGC AND 2009 IFC & IECC, AND IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS & REQUIREMENTS. 2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REQUIREMENTS AND INSPECTIONS POLICY. 3) WORK SHALL COMPLY WITH "COMMERCIAL LIMITED" ZONE DISTRICT REGULATIONS PER GARFIELD COUNTY'S LAND USE & DEVELOPMENT CODE. 4) BUILDINGS ARE APPROVED AS TYPE V -B NON-SPRINKLERED CONSTRUCTION WITH MIXED- USE OCCUPANCIES INCLUDING: OFFICE (GROUP B), LOW -HAZARD STORAGE (GROUP S-2), PRIVATE GARAGE (GROUP U) AND RESIDENTIAL (GROUP R-3). ALL OCCUPANCIES ARE INTENDED FOR SINGLE -TENANT USE. 5) PRIOR TO CONSTRUCTION, APPLICANT SHALL CONTACT LOCAL FIRE DISTRICT FOR I.F.C. REQUIREMENTS INCLUDING FIRE ALARM SYSTEMS & SMOKE ALARMS. PROVIDE COPY OF BUILDING PERMIT DRAWINGS TO FIRE DISTRICT FOR REVIEW & SIGN -OFF. FINAL APPROVAL REPORT FROM FIRE DISTRICT IS REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 6) EXISTING ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) TO BE ABANDONED, AND WASTE LINE CONNECTION TO BE TIED INTO NEW SEPTIC SYSTEM FOR FUTURE BUILDING (GARFIELD COUNTY BUILDING PERMIT #BLCO-06-16-4269). ENGINEER TO UP-SIZE PROPOSED SEPTIC SYSTEM AS ORIGINALLY SUBMITTED WITH THE ABOVE -REFERENCED BUILDING PERMIT, COMPLYING WITH ALL SETBACKS AND OTHER REQUIREMENTS PER GARFIELD COUNTY OWTS REGULATIONS. PROVIDE UPDATED SEPTIC SYSTEM DESIGN AND INSTALLATION PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) ACCESSIBILTY REQUIREMENTS PER 2015 IBC, CHAPTER 11, AND ICC A117.1-2009. (NOTE: ACCESSIBILITY IS NOT REQUIRED AT UPPER LEVEL RESIDENTIAL UNITS PER SECTION 1104.4, EXCEPTION #4). 8) LOCKS, LATCHES & LANDINGS PER 2015 IBC, SECTION 1010. 9) LIGHT AND VENTILATION PER 2015 IBC, CHAPTER 12. 10) BUILDING MECHANICAL SYSTEMS (COMBUSTION AIR, DUCTWORK & VENTING) TO COMPLY WITH INTERNATIONAL MECHANICAL CODE (IMC) AND IECC, SECTION 503. MECHANICAL ROUGH -IN INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION. 11) PLUMBING REQUIREMENTS PER INTERNATIONAL PLUMBING CODE (IPC). PLUMBING ROUGH -IN INSPECTION REQUIRED PRIOR TO FRAME INSPECTION. 12) ELECTRICAL REQUIREMENTS, PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL REQUIRED FOR FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY.