HomeMy WebLinkAbout1.0 ApplicationAPPLICATION FOR
AMENDMENT OF THE
LOS AMIGOS RANCH
PLANNED UNIT DEVELOPMENT
I. INTRODUCTION
The owners of the Los Amigos Ranch property, Mr.
Thomas E. Neal and Mr. James A.R. Johnson, hereby request
an amendment to the Planned Unit Development (PUD) project
which received approval in Resolution #79-15, dated
February 6, 1979. This request is made pursuant to the pro-
visions in the Garfield County Zoning Resolution adopted
and enacted on January 2, 1979, Section 10.00 Amendment.
The Los Amigos Ranch comprises 2,200 acres, more or
less, and is located along State Highway $2 and County Road
114, more particularly in the area known as Spring Valley.
The location of the property is shown on Figure 1, which
depicts adjacent property ownership. Current zoning of the
adjacent property is shown on Figure 2.
The request alters the original PUD amendment by re-
ducing the overall density from 56$ units to 423 units.
Single-family units increase in this amendment request
while multi -family units decrease. The revised PUD retains
some elements of.the original plan --the agricultural land,
open space, the school site and commercial site; and elimi-
nates duplex and patio horse units. The revised plan also
eliminates lengthy cul-de-sacs and flag lots which were on
the original plan. Figure 3, PUD Master Plan, illustrates
the amendments requested here.
IT. OBJECTIVES
The principal objective of the owners of Los Amigos
Ranch in seeking the PUD amendment is to create a housing
development that:
a) offers the types of housing that are responsive
to and consistent with current housing markets;
b) creates a more sound economic framework in which
the implimentation of the project can be real-
ized;
c) Offers a physical design approach which is
responsive to changed market conditions.
Also, the revised PUD amendment proposes a low density de-
velopment scheme which is, in the opinion of the owners,
of a higher quality and is more harmonious with the spec-
tacular environmental and visual characteristics of the
site than the currently approved multiple density/multiple
housing type plan.
The proposed PUD amendment also addresses present
Garfield County objectives related to growth in the area
southeast of Glenwood Springs, more specifically the Spring
Valley area. The amended PUD will, if approved:
a) reduce the traffic volumes on County Road 114
from what could be expected to result from build-
out of the currently approved PUD;
b) reduce the demand for additional public services
and public support services.
There will also be a reduced demand on available water from
the Spring Valley acquifer, and more flexibility in the
phasing of sanitation facilities can be realized by the
Spring Valley Sanitation District.
III. LAND USE AND DENSITIES
The area proposed for development in the PUD amendment
remain in the "mid zone" area between the steep bluffs
facing the Roaring Fork Valley'and the agricultural lands
of Spring Valley. This lineal development configuration on
rolling terrain is screened from the bluffs by pinion and
juniper vegetation. Other areas proposed for development
consist of "vest pocket" valleys and rolling slopes south
of County Road 114.
Table I compares the uses and types of units proposed
in the original PUD and the current amendment request.
The amended PUD plan represents an overall reduction of
155 units. A breakdown in the difference by unit type is
as follows:
o An increase of(41)single family units.
o Elimination of all 62 duplex units.
o Elimination of all 32 patio homes.
o Reduction of 68 ownhouses.
o Reduction of (24 multi -family units.
Low density, single family lots range in size from
1.6 acres to 5.7 acres. The three rural density sites are
approximately 68, 89 and 152 acres and have access from the
existing C.R. 114 and/or the proposed road network of the
Los Amigos Ranch PUD.
USE/UNIT TYPE
TABLE I
ORIGINAL PUD PUD AMENDMENT
UNITS ACRES
RESIDENTIAL:
• Single Family (122)
- Low Density (106)
- Rural Density ( 16)
• Duplex ( 62)
• Patio Home ( 32)
• Townhouse (124)
• Apartment, (228)
(696)
(253)
UNITS ACRE:
(163) (841)
(160) (531)
( 3) (310)
0 0
0 0
( 56) ( 8)
(204) ( 85)
RESIDENTIAL SUBTOTAL 568 949 423 934
AGRICULTURE 895 898
RECREATION/GREENBELT/
OPEN SPACE 288 304
SCHOOL SITE 8 8
COMMERCIAL SITE 20 3
ROADS 45 58
TOTAL 2205 2205
• -4-
The townhouse developments are located at the base
of the hill which faces the existing 48 student apartments.
this location is out of view from the premium single family
lots located on the same Neill. Density of the townhouse
development ranges between six to eight units per acre.
Each townhouse lot will be approximately 25 feet by 100
feet (2500 square feet) and includes private outdoor space.
The multi -family units (exclusive of the existing and
proposed 96 student apartments) are located on the lower
bench of land immediately adjacent to and south of C.R.
114. The 108 apartment units are located on a total parcel
size of 70 acres at the density of 1.54 units per acre.
However, the more realistic density increases to 3.4 per
acre when based on the developable land (15% slope and
less) of 31.35 acres.
The eight acre school site is located in the same gen-
eral area as shown on the original PUD Master Plan Map.
The 20 acre commercial site has been reduced in size to
not exceed three acres. The commercial uses permitted here
will provide convenience shopping to residents of Los
Amigos, the students at Colorado Mountain College and other
Spring Valley residents.
IV. DEVELOPMENT PHASING
The phasing of Los Amigos Ranch differs from the
original PUD Schedule due to the fact that projected real
estate absorption rates have reduced substantially from the
original 1979 approved plan, and the revised PUD Proposal
dramatically changes the types of units to be offered. The
proposed phasing schedule is based principally upon a logi-
cal pattern for the extension of utilities. The schedule
emphasizes the development and marketing of single family
lots prior to townhouse and multi -family development. The
proposed residential development, schedule is shown in Table
II.
The service commercial area is not scheduled for de-
velopment until there is actual need within the market area
which includes Los Amigos Ranch, Colorado Mountain College
and the remaining Spring Valley area. The school site will
also have roads and utilities in place when the Spring
Valley area population grows to the point that a school
is needed to service the area.
V. BUILDING SITING
A building site within each lot will be located and
defined in size. Most sites are located in areas of pinion
YEAR
• •
TABLE II
RESIDENTIAL DEVELOPMENT SCHEDULE
EXISTING PHASE 1 • PHASE 2 PHASE 3 TOTAL
1 2 3 4 5 6 7 $ 9
Low Density
Single -Family 9 15 30 21 17 17 17 17 17 160
Rural Density
Single -Family 1 1 1 3
Townhouses 11 11 11 11 12 56
Student
Apartments 4$ 48* 96
Multi -Family 21 21 21 21 24 108
YEAR TOTAL 48 10 16 31 69 49 49 49 49 53
PHASE TOTAL
48 57 167 151
423
423
*or at a time as deemed necessary to serve the demand for student housing
as determinted by Colorado Mountain College.
and juniper vegetation to take advantage of screening from
adjacent homesites, roads and public view. The building
sites will be specifically located at the time of final
subdivision platting for each phase of development and de-
velopment will be restricted within the building site
limits as governed hy the Subdivision Restrictive
Covenants.
VI. UTILITY SYSTEMS
A. Water
More than enough water is available to service the
revised PUD since the original density is about 25% greater
than now proposed. The major difference is the delivery
of water to formerly rural density single-family sites at
the far northwestern section of the site. This area was
originally to have water service by way of individual
wells, and the PUD amendment here incorporates this area
into the central water service system. A detailed descrip-
tion of the water service plan by Eldorado Engineering is
presented in
R. Sanitary Sewers
The revised development plan incorporates the same
area within Los Amigos Ranch to be serviced by the Spring
Valley Sanitation District, hut the number of units to be
served will he reduced. The original plan serviced
multi -family dwelling units plus the commercial and school
sites. (Duplex lots, 62 units, were to be served either
by the central system or individual septic systems and all
122 single-family lots were served hy individual septic
systems.)
As currently described, the area proposed to be served
within the limits of the sewer district are:
• The 96 student apartments.
el The 56 townhouses.
• 52 single-family lots.
to The school site.
e The commercial site.
This is a total of
sanitary sewer system.
to be served by the central
-7-
C. Remaining Utilities
Provisions for electricity, natural gas, telephone and
cable television remain as stated in the original PUD
Rezoning Request. '
VII. ROADS
The alignment of roads are depicted on the revised PUD
Master Plan and consists of approximately $ miles (42,000
lineal feet) . This compares with 11 .4 miles of roads in-
cluded on the original PUD Master Plan. The first phase of
development will utilize the street alignments which have
been planned, surveyed and graded as part of Subdivision 2,
Filing 1.
VIII. STATUS OF LOS AMIGOS SUBDIVISION NO. 2/FILING NO.
1
By virtue of this PUD Amendment Application, all repre-
sentations regarding the provision of public improvements
and facilities contained in the Subdivision Improvements
Agreement for Los Amigos Ranch Subdivision No. 2/Filing
No. 1 are hereby rendered null and void, and have no
effect. This change is necessitated by the change in the
PUD itself which provides for a different land use configur-
ation for the area currently under plat. It is anticipated
at this time that the area of Subdivision No. 2/Filing No.
1 will be submitted for consideration as a revised final
plat in due course. This area has been tentatively identi-
fied as construction phase #1. The Garfield County Planning
and Zoning Commission and Board of County Commissioners
should anticipate that this revised plat will be submitted
in timely fashion and as a first phase in the actual imple-
mentation of the Los Amigos Ranch PUD.
•
LOS AMIGOS P.U.D.
AMENDED PRELIMINARY UTILITY PLAN
The purpose of this report is to present the preliminary
plans and sizing for proposed utility systems for the
amended Los Amigos Ranch PUD. The proposed utility systems
will be interfaced with those systems already in place.
The sizing is based on the following unit mix (which in-
cludes the 4E existing apartment units):
Single Family, 163 units
Townhouse, 56 units
Apartment, 201 units
School Site
Commercial Site
For the purpose of this report, a per unit population of
3.5 and 3.0 will be used for single family and multi -family
units respectively.
Wastewater
The existing apartment units are served b the S ring
Valley Sanitation District. An "diameter interceptor sewer
line runs from the PUD site to the District's aerated lagoon
facility. The interceptor line is adequate to service the
proposed PUD development. The treatment system, however,
will have to be expanded in order to provide service.
The units within the present boundaries of the District
will be served by the central treatment facility. In addi-
tion, if economically feasible, an additional 29 single
family units adjacent to the District will be served. Ser-
vice will require pumping in several cases; more detailed
investigation with the District will be required to deter-
mine if inclusion of these units into the District is
desirable or feasible. If not included, they will be served
by individual systems.
The 180 multi -family units located on the lower bench will
be served either by the District, thereby requiring addi-
tional pumping facilities, or by a central treatment system
on site. At the time that development of this area is immi-
nent, the options for central treatment will have to be
further evaluated. It is possible for instance, that treat-
ment by a facility in the area of the CMC turnoff along
Highway 82 could be used at the Lirne development occurs.
•
•
-2-
The remaining 70 single family units will be served by indi-
vidual sewage systems. Individual site surveys and percola-
tion tests will determine whether standard septic tank/
leachfield systems or engineered systems will be required
Total central treatment requirements are:
Single Family, 54 units @ 350 gpd =
Multi -Family, 56 units @ 300 gpd
Apartments, 96 units @ 300 gpd =
School, @ 7000 gpd =
Commercial, @ 1000 gpd =
TOTAL
Single Family, 29 units @ 350 gpd
(to be determined)
18,900 gpd
16,800 gpd
28,$00 gpd
7,000 gpd
1,000 gpd
72,500 gpd
10,150 gpd
Multi -Family, 108 units @ 300 gpd 32,400 gpd
(lower bench area)
Water
The 48 existing apartment units are served by the Los Amigos
Water Company. The system consists of a groundwater source,
chlorination and hydropneumatic pumping system. To serve
the ultimate buildout of the PUD, the system will have to
be expanded to include an additional well supply, greater
chlorination capacity and ground storage located at the
high point of the property.
The units on the lower bench will be served by a separate
storage facility from the remainder of the PUD, but will
be served by the same source.
Total water demand is based on a domestic use plus lawn
irrigation use. Domestic use is calculated using the same
assumptions as outlined above for wastewater treatment re-
quirements. Irrigation requirements are based on an assumed
total acreage requirement of 23.9 acres and an application
rate of 2.5 A-f/A over 160 days. Total average daily demand
is estimated at 261,250 gpd (139,550 gpd domestic use and
121,700 gpd irrigation use).
Storage requirement is based on average day demand plus
a fire reserve equal to 500 gallons per unit for the lower
bench and 1500 gpm over 2 hours for the remainder of the
PUD. Total storage requirement is estimated at 100,000
gallons for the lower bench and 400,000 gallons for the
remaining PUD. The 400,000 gallons will be provided at two
locations - one above the multi -family site and one at the
west extreme end of the single family area. The exact size
will be determined by hydraulic modeling at the preliminary
plat stage. Based on a peaking factor of 3.0, total source
requirement is estimated at 540 gpm. Chlorination facilities
and the well field will be sized on this basis. A total
of 2 or 3 wells are anticipated to be required.
Fire protection will be provided, in part, by the distribu-
tion system. There are two areas where special conditions
are proposed, noting that the area of the PUD encompassing
the lower bench and the approximate Sanitation District
boundaries would have a minimum fire flow of 500 gpm at
20 psi residual pressure and hydrant spacings of 600' in
the single family area and 1500 gpm flows and closer spacing
in the multi -family areas. The first area is the cul-de-sac
adjacent to the tank site in the northeast portion of the
PUD. These five lots will require in-house booster pumps
for domestic use. The fire hydrant in the cul-de-sac will
not have 20 psi pressure and will, therefore, have to be
used as a source of water only, that is, the fire department
will use it as if it were a non -pressure source of water.
The hydrant will be designated as such in the field.
The second area is the single family area to the west of
the Sanitation District boundary. Because of the size and
distribution of lots and, therefore, the distance between
units, fire fighting would occur by transport of water to
a given site. Up to five (5) 10,000 gallon capacity cisterns
will be provided at strategic locations. These would be
connected to the water system with automatic fill arrange-
ments so that they would always be full. Gravelled access
will be provided to each fire fighting cistern.
Drainage
Because of the low density, no natural drainage courses
will be disturbed or relocated. All culverts will be de-
signed on a 10 year storm basis. It is not anticipated that
run-off quantities will be increased as a result of the
development, the additional green area offsetting the added
road and housing site areas. Natural overland flow pattern.;
will be continued.
Other Utilities
Please see main bod
Respectfully,
Dean W. Gordon
•vol 44*ti i! ttir11,4 I ot,, 0 t , ,, , , ,ik%s.' 32.
(-1\tarz-
1 = dors